In patients with osteoporosis there is always
a strong possibility that pedicle screws will loosen. This makes
it difficult to select the appropriate osteoporotic patient for
a spinal fusion. The purpose of this study was to determine the
correlation between bone mineral density (BMD) and the magnitude
of torque required to insert a pedicle screw. To accomplish this,
181 patients with degenerative disease of the lumbar spine were
studied prospectively. Each underwent dual-energy x-ray absorptiometry
(DEXA) and intra-operative measurement of the torque required to
insert each pedicle screw. The levels of torque generated in patients
with osteoporosis and osteopenia were significantly lower than those
achieved in normal patients. Positive correlations were observed between
BMD and T-value at the instrumented lumbar vertebrae, mean BMD and
mean T-value of the lumbar vertebrae, and mean BMD and mean T-value
of the proximal femur. The predictive torque (Nm) generated during pedicle
screw insertion was [-0.127 + 1.62 × (BMD at the corresponding lumbar
vertebrae)], as measured by linear regression analysis. The positive
correlation between BMD and the maximum torque required to insert
a pedicle screw suggests that pre-operative assessment of BMD may
be useful in determining the ultimate strength of fixation of a
device, as well as the number of levels that need to be fixed with
pedicle screws in patients who are suspected of having osteoporosis.
Good lag screw holding power in trabecular bone of the femoral head is a requisite to achieve stability in the management of proximal femoral fractures. It has been demonstrated that
Aims. To determine whether half-threaded screw holes in a new titanium locking plate design can substantially decrease the notch effects of the threads and increase the plate fatigue life. Methods. Three types (I to III) of titanium locking plates were fabricated to simulate plates used in the femur, tibia, and forearm. Two copies of each were fabricated using full- and half-threaded screw holes (called A and B, respectively). The mechanical strengths of the plates were evaluated according to the American Society for Testing and Materials (ASTM) F382-14, and the screw stability was assessed by measuring the screw removal torque and bending strength. Results. The B plates had fatigue lives 11- to 16-times higher than those of the A plates. Before cyclic loading, the screw removal torques were all higher than the
Introduction: With non-fusion stabilization surgery technique, the demands on the pedicle screw system have increased. The screw implants require a high press fit for optimum bone integration and a high pullout strength to guarantee primary stability. We compared the cylindrical screw design from a pedicle screw system with the conical design in regard to the
Introduction. Femoral neck fractures are a large clinical and economical problem. One of the most common fixation options for femoral neck fractures are multiple cancellous screws. A previous clinical study has shown the lack of washers to be the single largest predictor of fixation failure in the treatment of femoral neck fractures with cancellous screws. This finding was somewhat surprising as washers do not prevent the screws from backing out and do not provide any increase resistance to varus collapse. Therefore a follow-up biomechanical study was designed to test this observation. The purpose was to evaluate the maximal
Introduction: Deterioration of bone-pin interface, causing pin loosening and infection, is a major cause of postoperative complications following external fixation. This paper presents the results obtained using hydroxyapatite (HA)-coated pins in various bone types, such as osteoporotic bone. Materials And Methods; In an animal study comparing HA-coated and standard pins, pin insertion and extraction torque were measured. Subsequently, a clinical study compared
Objectives. Cement augmentation of pedicle screws could be used to improve screw stability, especially in osteoporotic vertebrae. However, little is known concerning the influence of different screw types and amount of cement applied. Therefore, the aim of this biomechanical in vitro study was to evaluate the effect of cement augmentation on the screw pull-out force in osteoporotic vertebrae, comparing different pedicle screws (solid and fenestrated) and cement volumes (0 mL, 1 mL or 3 mL). Materials and Methods. A total of 54 osteoporotic human cadaver thoracic and lumbar vertebrae were instrumented with pedicle screws (uncemented, solid cemented or fenestrated cemented) and augmented with high-viscosity PMMA cement (0 mL, 1 mL or 3 mL). The
Introduction. Conventional screws achieve sufficient
Purpose: Four external fixation pin types differing in coating, design and implantation technique were tested in an animal study. Methods: Forty tapered pins were divided into 4 Groups according to pin design type: Group A consisted of 10 standard self-tapping pins (ø5–6mm, pitch 1.75mm), Group B 10 hydroxyapatite (HA)-coated self-tapping (ø5–6mm, pitch 1.75mm), Group C 10 standard, self-drilling, self-tapping (ø5–6mm, pitch 1.25mm) and Group D 10 HA-coated, self-drilling, self-tapping (ø5–6mm, pitch 1.25mm). Four pins were randomly implanted into the femoral diaphysis of 10 sheep. The pins were implanted at 2-cm intervals apart. Pre-drilling was used for Groups A and B but not for Groups C and D. Sheep were euthanized 6 weeks after surgery. Results: There were no major complications. Mean pin
Purpose: Healing may be problematic after lag screw osteosynthesis of pertrochanteric fractures in osteoporotic bone due to the greater risk of defective fixation. Acrylic cement has been proposed to reinforce the fixation of the lag screw in these patients, principally to avoid the risk of cutout, but the acrylic cement’s thermal toxicity, its poor biocompatibility, and the difficult manipulation are important drawbacks. Cortoss® is a new composite biomaterial composed of bisphenol-aglycidly (bis-GMA) which could be an attractive alternative to classical cements. Cortoss is an injectable material with mechanical properties similar to human cortical bone. The purpose of this clinical study was to describe the new method for injection the material and to assess the anchoring force and safety of Cortoss in osteoporotic patients undergoing surgical fixation of pertrochanteric fractures. Material and methods: This prospective study was approved by the local ethics committee. Twenty consecutive patients aged 70 years or more with pertro-chanteric fracture were included. The lag screw was inserted under fluoroscopic guidance, and the maximum
We compared thirty-eight patients from three orthopaedic centres who had external fixation of the femur or the tibia. Patients were randomised to receive standard (tapered 5/6 millimeter) pins (Group A) or OsteoTite (hydroxyapatite coated tapered 5/6 mm) pins (Group B). In Group A there were 18 patients who received 71 pins. Average age of the patients was 49±12 years. Three patients had external fixation in the femur and 15 in the tibia. External fixation was used in three types of treatment: fracture fixation (4), knee osteotomy (12), and bone-transport (2). Two different fixator frames were used: a unilateral fixator was mounted in 15 patients and a circular fixator in three patients. In Group B, 20 patients (average age: ± 48 years) received 86 pins. Four patients had external fixation in the femur and 16 in the tibia. External fixation was used in three types of treatments: fracture fixation in three patients, knee osteotomy in 13 patients, and bone-transport in four patients. Two different fixator frames were used: a unilateral fixator was mounted in 16 patients and a circular fixator in four patients. No significant difference regarding sex, age, external fixation treatment type, external fixation frame, and length of treatment were observed between the two groups. Mean final pin
Introduction: External fixation is used widely in the management of fractures, despite a relatively high incidence of complication, arising from pin loosening and infection. Diamond like carbon (DLC) is a low surface energy coating that can be applied to external fixator pins and may reduce biofilm formation and infection resulting in a lower incidence of pin loosening. Hydroxyapatite (HA) is well established as a coating to enhance fixation of external fixator pins. This study tests the hypothesis that HA and DLC coatings on stainless steel (SS) external fixator pin shafts modify integration of the implant with soft/hard tissues. Materials and Methods: An Orthofix external fixator was used to stabilise a tibial osteotomy with 6 self-drilling/tapping 6mm pins in 32 skeletally mature Friesland ewes. Animals were divided into four groups; SS, DLC, HA partially coated (threads only) and HA fully coated (threads and pin shaft). Pin
Aims. To devise a method to quantify and optimize tightness when inserting cortical screws, based on bone characterization and screw geometry. Methods. Cortical human cadaveric diaphyseal tibiae screw holes (n = 20) underwent destructive testing to firstly establish the relationship between cortical thickness and experimental stripping torque (T. str. ), and secondly to calibrate an equation to predict T. str. Using the equation’s predictions, 3.5 mm screws were inserted (n = 66) to targeted torques representing 40% to 100% of T. str. , with recording of compression generated during tightening. Once the target torque had been achieved, immediate pullout testing was performed. Results. Cortical thickness predicted T. str. (R. 2. = 0.862; p < 0.001) as did an equation based on tensile yield stress, bone-screw friction coefficient, and screw geometries (R. 2. = 0.894; p < 0.001). Compression increased with screw tightness up to 80% of the maximum (R. 2. = 0.495; p < 0.001). Beyond 80%, further tightening generated no increase in compression. Pullout force did not change with variations in submaximal tightness beyond 40% of T. str. (R. 2. = 0.014; p = 0.175). Conclusion. Screw tightening between 70% and 80% of the predicted maximum generated optimum compression and pullout forces. Further tightening did not considerably increase compression, made no difference to pullout, and increased the risk of the screw holes being stripped. While further work is needed for development of intraoperative methods for accurate and reliable prediction of the maximum tightness for a screw, this work justifies
Introduction The AO/ASIF 3.5 mm STS is increasingly used for internal fixation of large bones with the recent introduction of the 3.5 mm periarticular plating system. Our study aims to compare the
The effect of screw geometry on the pullout strength of Anterior Cruciate Ligament [ACL] reconstruction is well documented. Most research has looked at the effect of screw length and diameter, however other factors such as the degree of taper may also be important. Tapered screws should in theory be associated with increased pullout strength. This has not been demonstrated either clinically or in vitro before. The aim of this study was to compare the pullout strength of ACL reconstruction with a parallel against a tapered screw. A parallel and tapered screw were manufactured which were identical in all other respects. Sixty superficial digital flexors from the hind legs of sheep were harvested. The tendons were paired and combined to form a quadruple tendon reconstruction of approximately 7mm diameter as measured with graft sizer. An ACL reconstruction was performed on the proximal tibia of 30 bovine knees, which had been harvested in right and left knee pairs, using the quadruple tendon. Fifteen reconstructions were fixed using tapered screws and fifteen with non-tapered screws. The
Nearly a quarter of screws cause damage during insertion by stripping the bone, reducing pullout strength by over 80%. Studies assessing surgically achieved tightness have predominately shown that variations between individual surgeons can lead to underpowered investigations. Further to the variables that have been previously explored, several basic aspects related to tightening screws have not been evaluated with regards to how they affect screw insertion. This study aims to identify the achieved tightness for several variables, firstly to better understand factors related to achieving optimal intraoperative screw purchase and secondly to establish improved methodologies for future studies. Two torque screwdrivers were used consecutively by two orthopaedic surgeons to insert 60 cortical, non-locking, stainless-steel screws of 3.5 mm diameter through a 3.5 mm plate, into custom-made 4 mm thick 20 PCF sheets of Sawbone, mounted on a custom-made jig. Screws were inserted to optimal tightness subjectively chosen by each surgeon. The jig was attached to a bench for vertical screw insertion, before a further 60 screws were inserted using the first torque screwdriver with the jig mounted vertically, enabling horizontal screw insertion. Following the decision to use the first screwdriver to insert the remaining screws in the vertical position for the other variables, the following test parameters were assessed with 60 screws inserted per surgeon: without gloves, double surgical gloves, single surgical gloves, non-sterile nitrile gloves and, with and then without augmented feedback (using digitally displayed real-time achieved torque). For all tests, except when augmented feedback was used, the surgeon was blinded to the
Introduction. Loosening of the baseplate is one of the most common causes of failure in Reverse Shoulder Arthroplasty. To allow osteo-integration to occur and thus provide long-term stability, initial screws fixation plays a pivotal role. In particular, tightening torque and force of nonlocking screws are two parameters that are considered to have a clear impact on implant stability, yet the relation is not fully understood. For this reason, this study aims to define an experimental set-up, to measure force and torque in artificial bone samples of different quality, in order to estimate ranges of optimal surgical values and give guidelines to maximize screw fixation and therefore initial implant stability. Methods. A custom-made torque sensor (Figure 1a) was built and calibrated using a lever deadweight system. To measure the compression force generated by the screw head, three thin FlexiForce sensors (Tekscan, South Boston, US) were enclosed between two 3D printed plates with a central hole to allow screw insertion (Figure 1b). The tightening force, represented by the sum of the three sensors, was calibrated using a uniaxial testing machine (Zwick/Roell, Ulm, Germany). Multiple screw lengths (26mm, 32mm and 47mm) were selected in the protocol. Synthetic bone blocks (Sawbones; Malmö, Sweden) of 20 and 30 PCF were used to account for bone quality variation. To evaluate the effect of a cortical bone layer, for each density three blocks were considered with 0 mm (no layer), 1.5 mm and 3 mm of laminate foam of 50 PCF. The holes for the screws were pre-drilled in the same way as in the operation room. For each combination of screw dimensions and bone quality, ten measurements were performed by acquiring the signal of the
The February 2024 Spine Roundup360 looks at: Surgeon assessment of bone – any good?; Robotics reduces radiation exposure in some spinal surgery; Interbody fusion cage versus anterior lumbar interbody fusion with posterior instrumentation; Is robotic-assisted pedicle screw placement an answer to the learning curve?; Acute non-traumatic spinal subarachnoid haematomas: a report of five cases and a systematic review of the literature; Is L4-L5 lateral interbody fusion safe and effective?
We investigated the effects of hydroxyapatite (HA) coating on the purchase of pedicle screws. A total of 23 consecutive patients undergoing lumbar fusion was randomly assigned to one of three treatment groups. The first received uncoated stainless-steel screws, the second screws which were partly coated with HA, and the third screws which were fully coated. The
Summary. A rotational limit for screw insertion may improve screw purchase and plate compression by reducing stripping, as compared to a torque based limit. Introduction. Over-tightening screws results in inadvertent stripping of 20% of cortical bone screws. The current method of “two-fingers tight” to insert screws relies on the surgeon receiving torque feedback. Torque, however, can be affected by screw pitch, bone density and bone-thread friction. An alternative method of tightening screws is the “turn-of-the-nut” model, commonly used in engineering applications. In the “turn-of-the-nut” method, nuts used to fasten a joint are rotated a specific amount in order to achieve a pre-specified bolt tension. When applied to orthopaedics, bone assumes the role of the nut and the screw is the bolt. The screw is turned a set angular rotation that is independent of torque feedback. Potentially the “turn-of-the-nut” method provides an easier way of screw insertion that might lessen inadvertent screw stripping. The purpose of the current study was to use the “turn-of-the-nut” method to determine the angular rotation that results in peak plate compression and peak screw pullout force. Methods. Three pairs of human humeri in each of three groups (osteopenic, osteoporotic, and normal) underwent plate compression and pullout protocols. For plate compression, 3.5-mm screws were tightened into strain gauge instrumented plate until screw stripping occurred.