Introduction. Pelvic discontinuity is a challenging complication. One treatment option that has garnered enthusiasm is acetabular distraction. This method obtains stability via distraction of the discontinuity and placement of an oversized socket (± augments) and elastic recoil of the pelvis. The aims of this study were to report
Aims. Total hip arthroplasty (THA) is a very successful and cost-effective operation, yet debate continues about the optimum fixation philosophy in different age groups. The concept of the 'cementless paradox' and the UK 'Getting it Right First Time' initiative encourage increased use of cemented fixation due to purported lower revision rates, especially in elderly patients, and decreased cost. Methods. In a high-volume, tertiary referral centre, we identified 10,112 THAs from a prospectively collected database, including 1,699 cemented THAs, 5,782 hybrid THAs, and 2,631 cementless THAs. The endpoint was revision for any reason. Secondary analysis included examination of
Patients with a high comorbidity burden (high-risk) can achieve similar improvements in quality of life compared to low-risk patients, but greater morbidity may deter surgeons from operating on these patients. Whether surgeon volume influences THA outcomes in high-risk patients has not been investigated. This study aimed to compare complication rates and
This study evaluates patient reported outcome measurement information system (PROMIS) scores after total hip arthroplasty (THA) and total ankle arthroplasty (TAA) in matched cohorts, while simultaneously evaluating
Aims. Contemporary outcomes of primary total hip arthroplasties (THAs) with highly cross-linked polyethylene (HXLPE) liners in patients with inflammatory arthritis have not been well studied. This study examined the
Aims. United Classification System (UCS) B2 and B3 periprosthetic fractures in total hip arthroplasties (THAs) have been commonly managed with modular tapered stems. No study has evaluated the use of monoblock fluted tapered titanium stems for this indication. This study aimed to evaluate the effects of a monoblock stems on
The use of trabecular metal (TM.) shells supported by two TM augments in the footing technique has been described as a potential option for the treatment of Paprosky 3B acetabular defects. The aim of this study was to assess the mid
There is a paucity of data available for the use of Total Femoral Arthroplasty (TFA) for joint reconstruction in the non-oncological setting. The aim of this study was to evaluate TFA outcomes with minimum 5-year follow-up. This was a retrospective database study of TFAs performed at a UK tertiary referral revision arthroplasty unit. Inclusion criteria were patients undergoing TFA for non-oncological indications. We report demographics, indications for TFA,
Cup-cage constructs are one of several methods commonly used to treat severe acetabular bone loss during contemporary revision total hip arthroplasty. The purpose of this study was to provide a long-term results of the technique with emphasis on
There is a paucity of long-term data on modular fluted tapered (MFT) stems for two-stage reimplantation following periprosthetic joint infection (PJI). The purpose of this study was to evaluate
Femoral stem design affects periprosthetic bone mineral density (BMD), which may impact long term survival of cementless implants in total hip arthroplasty (THA). The aim of this study was to examine proximal femoral BMD in three morphologically different uncemented femoral stems designs to investigate whether one particular design resulted in improved preservation of BMD. 119 patients were randomized to receive either a proximally coated dual taper wedge stem, a proximally coated anatomic stem or a fully coated collarless triple tapered stem. Dual energy x-ray absorptiometry scans (Lunar iDXA, GE Healthcare, Madison, WI) assessed BMD across the seven Gruen zones pre-operatively, and post-operatively at 6-weeks, 1-year, and 2-years comparing the unoperated contralateral femur as a control. BMD increased in zones one (2.5%), two (17.1%), three (13.0%), five (10%) and six (17.9%) for all stems. Greater preservation of BMD was measured on the lateral cortex (zone 2) for both the dual taper wedge and anatomic stems (p = 0.019). The dual taper wedge stem also demonstrated preservation of BMD in the medial calcar (zone 7) whilst the anatomic and triple taper stem declined in this region, however this was not statistically significant (p = 0.059). BMD decreased on average by 2.1% in the mid-diaphysis region, distal to the stem tip (zone 4) for all implants. All stems performed equivalently at final follow-up in all patient reported outcome measures. Implant design was shown to impact BMD changes. All stems preserved bone at the metaphyseal level in early follow-up, which theoretically indicates favorable implant fixation. There was no significant stress shielding observed, however longer follow-up is required to elucidate the impact of this finding on
Angular proximal femoral deformities increase the technical complexity of primary total hip arthroplasties (THAs). The goals were to determine the long-term
The last two decades have seen remarkable technological advances in total hip arthroplasty (THA) implant design. Porous ingrowth surfaces and highly crosslinked polyethylene (HXLPE) have been expected to dramatically improve
Aims. The prevalence of ipsilateral total hip arthroplasty (THA) and total knee arthroplasty (TKA) is rising in concert with life expectancy, putting more patients at risk for interprosthetic femur fractures (IPFFs). Our study aimed to assess treatment methodologies,
Aims. This study compared multiple sclerosis (MS) patients who underwent
primary total hip arthroplasty (THA) with a matched cohort. Specifically,
we evaluated: 1)
Uncemented component retention with polyethylene (PE) liner and femoral head exchange is commonly used to treat periprosthetic osteolysis. The purpose was to determine long-term
Patients who have multiple sclerosis (MS) may be at increased risk of developing complications after total hip arthroplasty (THA). The purpose of this study was to compare: 1)
Aims. This study reports the mid-term results of total hip arthroplasty (THA) performed using a monoblock acetabular component with a large-diameter head (LDH) ceramic-on-ceramic (CoC) bearing. Patients and Methods. Of the 276 hips (246 patients) included in this study, 264 (96%) were reviewed at a mean of 67 months (48 to 79) postoperatively. Procedures were performed with a mini posterior approach. Clinical and radiological outcomes were recorded at regular intervals. A noise assessment questionnaire was completed at last follow-up. Results. There were four re-operations (1%) including one early revision for insufficient primary fixation (0.4%). No hip dislocation was reported. The mean University of California, Los Angeles (UCLA) activity score, 12-Item Short-Form Health Survey (SF-12) Mental Component Summary (MCS) score, SF-12 Physical Component Summary (PCS) score, Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) score, and Forgotten Joint Score (FJS) were 6.6 (2 to 10), 52.8 (25.5 to 65.7), 53.0 (27.2 to 66.5), 7.7 (0 to 63), and 88.5 (23 to 100), respectively. No signs of loosening or osteolysis were observed on radiological review. The incidence of squeaking was 23% (n = 51/225). Squeaking was significantly associated with larger head diameter (p < 0.001), younger age (p < 0.001), higher SF-12 PCS (p < 0.001), and UCLA scores (p < 0.001). Squeaking did not affect patient satisfaction, with 100% of the squeaking hips satisfied with the surgery. Conclusion. LDH CoC THAs have demonstrated excellent functional outcomes at medium-term follow-up, with very low revision rate and no dislocations. The high incidence of squeaking did not affect patient satisfaction or function. LDH CoC with a monoblock acetabular component has the potential to provide long term
Introduction. Patients undergoing primary total hip arthroplasty (THA) following pelvic radiation have historically had poor survivorship free of aseptic acetabular component loosening. However, several series have reported improved results with tantalum acetabular components. The purpose of this study was to assess
Background. The impact of a patient's activity level following total hip arthroplasty (THA) remains controversial, with some concerned about increased polyethylene wear, aseptic loosening and revisions. The purpose of this study is to report on