Aim. To examine the mid-term survival, clinical and patient reported outcomes of the silastic 1. st. metatarsophalangeal joint replacement for the treatment of end stage hallux rigidus. Methods. We reviewed 83 consecutive silastic arthroplasties performed in 79 patients for end stage hallux rigidus. There were 3 men and 76 women; mean age 63 years (range 45–78 years). No patient was lost to follow up. Average follow-up was 5.3 years (1.1–11.3 years). The EQ 5D–5L Health index, Manchester-Oxford Foot Questionnaire (MOXFQ), visual analogue scale (VAS) of pain and overall satisfaction rate (Likert scale) were collected for patient reported outcomes. Results. 2 patients required revision; 1 for early infection (2 months) and 1 for stem breakage (10 years 1 month). 5 patients reported lateral metatarsalgia, 2 patients reported neuropathic pain, 6 patients developed superficial infection which fully responded to oral antibiotics, and 1 patient developed interphalangeal joint pain. 2 patients died in the cohort. Pre-operative mean MOXFQ was 44, mean EQ5D Index was 0.564 and VAS was 6.97. At mean follow-up of 5.3 years, the mean MOXFQ was 12.7 (0–57), the mean EQ5D Index was 0.851 (−0.02–1) and the mean VAS was 1.67 (0–8). The mean range of motion was 35° (30° dorsiflexion and 5° plantarflexion). The overall satisfaction rate was 90.2%. The
We present a review of 97 consecutive BioPro® metallic hemiarthroplasties performed in 80 patients for end-stage hallux rigidus, with a minimum of five years follow-up. The mean age of the cohort was 55 (22 to 74) years. No patient was lost to follow-up. There were 15 revisions performed, one for infection, two for osteolysis, and 12 for pain. The all cause survival rate at five years was 85.6% (95% confidence interval (CI) 83.5 to 87.9). Younger age was a significant predictor of revision (odds ratio 1.09, 95% CI 1.02 to 1.17, p=0.014) on excluding infection and adjusting for confounding variables (Cox regression). Significant improvements were demonstrated at 5 years in the Manchester Oxford foot questionnaire (13.9, 95% CI 10.5 to 17.2) and in the physical component of the short form 12 score (6.5, 95% CI 4.1 to 8.9). The overall satisfaction rate was 72%. The cost per quality-adjusted-life-year at 5 years, accounting for a 3% per year revision rate, was £3,714. The BioPro offers good short to mid-term functional outcome and is a cost effective intervention. The relative high revision rate is associated with younger age and the use of this implant may be limited to older patients.
Aims. We report the long-term clinical and radiological outcomes of a consecutive series of 200 total ankle arthroplasties (TAAs, 184 patients) at a single centre using the Scandinavian Total Ankle Replacement (STAR) implants. Patients and Methods. Between November 1993 and February 2000, 200 consecutive STAR prostheses were implanted in 184 patients by a single surgeon. Demographic and clinical data were collected prospectively and the last available status was recorded for further survival analysis. All surviving patients underwent regular clinical and radiological review. Pain and function were assessed using the American Orthopaedic Foot and Ankle Society (AOFAS) hindfoot scoring system. The principal endpoint of the study was failure of the implant requiring revision of one or all of the components. Kaplan–Meier survival curves were generated with 95% confidence intervals and the rate of failure calculated for each year. Results. A total of 84 patients (87 ankles) were alive by the end of this study. Of the surviving 84 patients (87 ankles; rheumatoid arthritis (RA), n = 40; OA, n = 47), 45 were women and 39 were men, with a mean age of 54 years (18 to 72 years) at the time of surgery. A total of 32 implants failed (16%), requiring revision surgery. The mean time to revision was 80 months (2 to 257). The
Background. The literature on the outcome of revision total ankle arthroplasty (TAA) remains limited. We aim to report the clinical and radiological outcomes of revision TAA at a high-volume centre in the UK. Methods. Retrospective review of 28 patients that underwent 29 revision TAA procedures using INBONE II prosthesis. Demographic, radiological, and patient reported outcome measures data were analysed. Results. The mean (range) duration from primary TAA to revision was 87.5 (16–223) months. The main indication for the revision was aseptic loosening of the primary TAA (82.8%). Additional procedures were required in 75.9% of patients. At mean (range) follow-up of 40 (24- 60) months, the infection, re-operation, and
Introduction/Purpose. A randomized clinical trial of first MTP joint hemiarthroplasty with a synthetic cartilage implant demonstrated equivalent pain, function and safety outcomes to first MTP joint arthrodesis at 2 years. Recognizing that many hemiarthroplasty and total toe implants have initially good results that deteriorate over time, the purpose of this study was to prospectively assess the safety and efficacy outcomes for the synthetic cartilage implant population and to determine if the excellent outcomes were maintained at >5 years. Methods. One hundred nineteen patients were evaluated at 5+ years; 23 could not be reached for follow-up, but implant status was available for 7 of these subjects. Patients completed a pain visual analogue scale (VAS) and Foot and Ankle Ability Measure (FAAM) Sports and Activities of Daily Living (ADL) scores, preoperatively and at 2, 6, 12, 26, 52, 104 and 260 weeks postoperatively. Minimal clinically important differences are: ≥30% difference for pain VAS, 9 points for FAAM Sports, and 8 points for FAAM ADL. Great toe active dorsiflexion, weight-bearing radiographs, secondary procedures, and safety parameters were evaluated. Results. Of 119 patients available at mean 5.8 years follow-up (SD ±0.7; range: 4.4–8.0), 9 underwent implant removal and conversion to fusion in years 2–5, leaving 106 patients. The
Aims. We report the medium-term outcomes of a consecutive series of 118 Zenith total ankle arthroplasties (TAAs) from a single, non-designer centre. Methods. Between December 2010 and May 2016, 118 consecutive Zenith prostheses were implanted in 114 patients. Demographic, clinical, and patient-reported outcome measures (PROMs) data were collected. The endpoint of the study was failure of the implant requiring revision of one or all of the components. Kaplan-Meier survival curves were generated with 95% confidence intervals (CIs) and the rate of failure calculated for each year. Results. Eight patients (ten ankles) died during follow-up, but none required revision. Of the surviving 106 patients (108 ankles: rheumatoid arthritis (RA), n = 15; osteoarthritis (OA), n = 93), 38 were women and 68 were men, with a mean age of 68.2 years (48 to 86) at the time of surgery. Mean follow-up was 5.1 years (2.1 to 9.0). A total of ten implants failed (8.5%), thus requiring revision. The
The purpose of this study was to assess the success rate and functional outcomes of bone grafting for periprosthetic bone cysts following total ankle arthroplasty (TAA). Additionally, we evaluated the rate of graft incorporation and identified associated predisposing factors using CT scan. We reviewed a total of 37 ankles (34 patients) that had undergone bone grafting for periprosthetic bone cysts. A CT scan was performed one year after bone grafting to check the status of graft incorporation. For accurate analysis of cyst volumes and their postoperative changes, 3D-reconstructed CT scan processed with 3D software was used. For functional outcomes, variables such as the Ankle Osteoarthritis Scale score and the visual analogue scale for pain were measured.Aims
Methods
Despite the increasing numbers of ankle arthroplasties, there are limited studies on their survival and comparisons between different implants. The primary aim of this study was to determine the failure rates of primary ankle arthroplasties commonly used in the UK. A data linkage study combined National Joint Registry (NJR) data and NHS Digital data. The primary outcome of failure was defined as the removal or exchange of any components of the implanted device. Life tables and Kaplan-Meier survival charts were used to illustrate survivorship. Cox proportional hazards regression models were fitted to compare failure rates between 1 April 2010 and 31 December 2018.Aims
Methods
Implant failure has become more common as the number of primary total ankle arthroplasties (TAAs) performed has increased. Although revision arthroplasty has gained attention for functional preservation, the long-term results remain unclear. This study aimed to assess the long-term outcomes of revision TAA using a mobile-bearing prosthesis in a considerably large cohort; the risk factors for failure were also determined. This single-centre retrospective cohort study included 116 patients (117 ankles) who underwent revision TAA for failed primary TAA between July 2000 and March 2010. Survival analysis and risk factor assessment were performed, and clinical performance and patient satisfaction were evaluated preoperatively and at last follow-up.Aims
Methods
The Zenith. TM. total ankle replacement (Corin, Cirencester) is a mobile-bearing implant based on the Buechal Pappas design. Key features are the simple fully-jigged instrumentation aiming to improve accuracy and reproducibility of implant positioning, cementless calcium phosphate coated surfaces for improved early osseointegration, and titanium nitride-coated bearing surfaces to resist wear. We present early to mid-term survival data for 155 total ankle replacements implanted by three surgeons in our institute. Case records of all patients undergoing Zenith. TM. Total Ankle Replacement by three senior surgeons, including a member of the design team, between 2007 and 2014 were examined. Patients were examined clinically and radiographically annually after the early postoperative period. The primary outcome measure was
The aim of this study was to capture 12-month outcomes from a representative multicentre cohort of patients undergoing total ankle arthroplasty (TAA), describe the pattern of patient-reported outcome measures (PROMs) at 12 months, and identify predictors of these outcome measures. Patients listed for a primary TAA at 19 NHS hospitals between February 2016 and October 2017 were eligible. PROMs data were collected preoperatively and at six and 12 months including: Manchester-Oxford Foot and Ankle Questionnaire (MOXFQ (foot and ankle)) and the EuroQol five-dimension five-level questionnaire (EQ-5D-5L). Radiological pre- and postoperative data included Kellgren-Lawrence score and implant position measurement. This was supplemented by data from the National Joint Registry through record linkage to determine: American Society of Anesthesiologists (ASA) grade at index procedure; indication for surgery, index ankle previous fracture; tibial hind foot alignment; additional surgery at the time of TAA; and implant type. Multivariate regression models assessed outcomes, and the relationship between MOXFQ and EQ-5D-5L outcomes, with patient characteristics.Aims
Methods
This study reports updates the previously published two-year clinical, functional, and radiological results of a group of patients who underwent transfibular total ankle arthroplasty (TAA), with follow-up extended to a minimum of five years. We prospectively evaluated 89 patients who underwent transfibular TAA for end-stage osteoarthritis. Patients’ clinical and radiological examinations were collected pre- and postoperatively at six months and then annually for up to five years of follow-up. Three patients were lost at the final follow-up with a total of 86 patients at the final follow-up.Aims
Methods
Introduction. Traditional treatment for end-stage ankle arthritis has been ankle arthrodesis, however ankle arthroplasty is becoming an accepted alternative. The Zenith Ankle (Corin, UK) is 3rd generation implant with a mobile bearing design. In the NJR 2016 report, the Zenith was the commonest ankle prosthesis implanted in the UK. However, compared to other ankle implants, there's little published data on its performance and survival. The aim of this study was to analyse outcome in a consecutive series from a non-designer centre. Method. We conducted a retrospective review of a consecutive series of 118 Zenith Ankle replacements implanted in our Unit (December 2010 to May 2016). Data was collected from our National Joint Registry entries, research databases, patient notes, PACS and PROMS. Results. Average age was 68.2 years (range 46–46 years; 75M:43F; 97 Osteoarthritis, 20 inflammatory arthritis, 1 haemophilia). Results show a 95.8% survivorship at average 3.5 years follow up (range 0.6–6.3 years). 5 patients (4.2%) required revision. Average pre- and post-op MOXFQ scores were 85.0/100 and 32/100 respectively with improvements in VAS from 7.0/10 to 3.6/10, with an average range of movement of 20.4 degrees. Overall satisfaction rate was 89%. There were 65 complications in 55 patients, but only 7.7% of these led to detrimental effects on the implant. The commonest were malleolar fracture (14.4%), wound problems (13.6%) and superficial infection (12.7%), medial gutter pain (10.2%). There were no cases of deep infection. Five patients required revision (all were revised to revision arthroplasty), for component loosening, or pain and stiffness. Conclusions. This is largest non-designer centre series examining the outcomes of the Zenith
Introduction:. The Scandinavian Total Ankle Replacement (STAR) is a three-component, uncemented implant in widespread use throughout Europe. STAR has achieved encouraging results with short and medium term outcome. We present the long term (13–19 year) results of a consecutive series of 200 STAR ankles. Methods:. Between November 1993 and February 2000, a total of 200 consecutive STARs were carried out in 184 patients. Patients were followed up both clinically and radiologically, until death or failure, with time to decision to revision or fusion as the endpoint. Pain and function were assessed using the American Orthopaedic Foot and Ankle Society (AOFAS) ankle and hindfoot score. Results:. Of the 200 STARs, 109 (105 patients) were alive at latest review. 12 STARs (11 patients) were lost to follow-up, leaving 97 ankles for clinical review. Of these, 76 ankles were surviving and 21 ankles had failed [13 underwent arthrodesis, 4 had an exchange of poly insert, and 4 had a revision TAR], with mean time to failure 82 months (2–156 months). For the 91 ankles in 79 patients who died during the study, 8 had failed [6 underwent revision TAR and 2 had an arthrodesis]. The
Preoperative talar valgus deformity ≥ 15° is considered a contraindication for total ankle arthroplasty (TAA). We compared operative procedures and clinical outcomes of TAA in patients with talar valgus deformity ≥ 15° and < 15°. A matched cohort of patients similar for demographics and components used but differing in preoperative coronal-plane tibiotalar valgus deformity ≥ 15° (valgus, n = 50; 52% male, mean age 65.8 years (SD 10.3), mean body mass index (BMI) 29.4 (SD 5.2)) or < 15° (control, n = 50; 58% male, mean age 65.6 years (SD 9.8), mean BMI 28.7 (SD 4.2)), underwent TAA by one surgeon. Preoperative and postoperative radiographs, Ankle Osteoarthritis Scale (AOS) pain and disability and 36-item Short Form Health Survey (SF-36) version 2 scores were collected prospectively. Ancillary procedures, secondary procedures, and complications were recorded.Aims
Methods
To assess the effect of age on clinical outcome and revision rates in patients who underwent total ankle arthroplasty (TAA) for end-stage ankle osteoarthritis (OA). A consecutive series of 811 ankles (789 patients) that underwent TAA between May 2003 and December 2013 were enrolled. The influence of age on clinical outcome, including the American Orthopaedic Foot and Ankle Society (AOFAS) hindfoot score, and pain according to the visual analogue scale (VAS) was assessed. In addition, the risk for revision surgery that includes soft tissue procedures, periarticular arthrodeses/osteotomies, ankle joint debridement, and/or inlay exchange (defined as minor revision), as well as the risk for revision surgery necessitating the exchange of any of the metallic components or removal of implant followed by ankle/hindfoot fusion (defined as major revision) was calculated.Aims
Methods
Arthroplasty for end-stage hallux rigidus (HR) is controversial. Arthrodesis remains the gold standard for surgical treatment, although is not without its complications, with rates of up to 10% for nonunion, 14% for reoperation and 10% for metatarsalgia. The aim of this study was to analyze the outcome of a double-stemmed silastic implant (Wright-Medical, Memphis, Tennessee, USA) for patients with end-stage HR. We conducted a retrospective review of 108 consecutive implants in 76 patients, between January 2005 and December 2016, with a minimum follow-up of two years. The mean age of the patients at the time of surgery was 61.6 years (42 to 84). There were 104 females and four males. Clinical, radiological, patient reported outcome measures (PROMS) data, a visual analogue score (VAS) for pain, and satisfaction scores were collected.Aims
Methods
Total ankle arthroplasty (TAA) surgery is complex and attracts a wide variety of complications. The literature lacks consistency in reporting adverse events and complications. The aim of this article is to provide a comprehensive analysis of each of these complications from a literature review, and to compare them with rates from our Unit, to aid clinicians with the process of informed consent. A total of 278 consecutive total ankle arthroplasties (251 patients), performed by four surgeons over a six-year period in Wrightington Hospital (Wigan, United Kingdom) were prospectively reviewed. There were 143 men and 108 women with a mean age of 64 years (41 to 86). The data were recorded on each follow-up visit. Any complications either during initial hospital stay or subsequently reported on follow-ups were recorded, investigated, monitored, and treated as warranted. Literature search included the studies reporting the outcomes and complications of TAA implants.Aims
Patients and Methods
To examine the mid-term outcome and cost utility of the BioPro
metallic hemiarthroplasty for the treatment of hallux rigidius. We reviewed 97 consecutive BioPro metallic hemiarthroplasties
performed in 80 patients for end-stage hallux rigidus, with a minimum
follow-up of five years. There were 19 men and 61 women; their mean
age was 55 years (22 to 74). No patient was lost to follow-up.Aims
Patients and Methods
Few reports compare the contribution of the talonavicular articulation
to overall range of movement in the sagittal plane after total ankle
arthroplasty (TAA) and tibiotalar arthrodesis. The purpose of this
study was to assess changes in ROM and functional outcomes following
tibiotalar arthrodesis and TAA. Patients who underwent isolated tibiotalar arthrodesis or TAA
with greater than two-year follow-up were enrolled in the study.
Overall arc of movement and talonavicular movement in the sagittal
plane were assessed with weight-bearing lateral maximum dorsiflexion
and plantarflexion radiographs. All patients completed Short Form-12
version 2.0 questionnaires, visual analogue scale for pain (VAS)
scores, and the Foot and Ankle Ability Measure (FAAM).Aims
Patients and Methods