Total joint arthroplasty (TJA) is one of the commonest and most successful orthopaedic procedures, used for the management of end-stage arthritis. With the recent introduction of robotic assisted joint replacement, Computed Tomography (CT) has become part of required pre-operative planning. The aim of this study is to quantify and characterise incidental CT findings, their clinical significance, and their effect on planned joint arthroplasty. All consecutive patients undergoing an elective TJR (hip or knee arthroplasty) were retrospectively identified, over a 3-year period (December 2019 and December 2022). Data documented and analysed included patient demographics, type of joint arthroplasty, CT findings, their clinical significance, as well as potential delays to the planned arthroplasty because of these findings and subsequent further investigation.Abstract
Introduction
Methodology
Although knee osteoarthritis (OA) is diagnosed and monitored radiologically, actual full-thickness cartilage loss (FTCL) has rarely been correlated with radiological classification. This study aims to analyze which classification system correlates best with FTCL and to assess their reliability. A prospective study of 300 consecutive patients undergoing unilateral total knee arthroplasty (TKA) for OA (mean age 69 years (44 to 91; standard deviation (SD) 9.5), 178 (59%) female). Two blinded examiners independently graded preoperative radiographs using five common systems: Kellgren-Lawrence (KL); International Knee Documentation Committee (IKDC); Fairbank; Brandt; and Ahlbäck. Interobserver agreement was assessed using the intraclass correlation coefficient (ICC). Intraoperatively, anterior cruciate ligament (ACL) status and the presence of FTCL in 16 regions of interest were recorded. Radiological classification and FTCL were correlated using the Spearman correlation coefficient.Aims
Methods
The purpose of this study was to determine the accuracy of MRI scan for the detection of meniscal pathology in our unit. There are published data which show that both sensitivity and specificity can approach 90% when compared to arthroscopic findings. We retrospectively analysed a single surgeon series of 240 scopes for all indications The arthroscopic reports included an outline diagram of the meniscus upon which the surgeon recorded operative findings. 112 of these patients had also had recent MRI. We looked at whether the MRI report showed a tear, and this was graded Y/N. The arthroscopic report was graded for tear: Y/N. 66 patients had a positive scan. 64 of these were found to have a tear at surgery. 37 scans were reported as “no tear”, of which 4 were found to have a tear at surgery. Nine scans were not easy to classify as they were descriptive. In our series of 112 knees, MRI was 90.5% sensitive, 89.5% specific and 90.1% accurate. When a definite diagnosis of “tear”, or “no tear” was made at scan, there were two false positives and four false negatives. False positives may be unnecessarily exposed to the risks of surgery. Patients with negative scans had a mean delay to surgery of 33 weeks compared to 18 weeks for patients with positive scans. False negatives may wait longer for their surgery. Two of the false negative scans clearly showed meniscus tears which were missed by the reporting radiographer. In our series the scan itself was more accurate than the reporting. It is important to have an experienced musculoskeletal radiologist to minimise the number of missed tears. It is also important for surgeon to check the scan as well as the report.
The radiological and MRI appearances of 24 knees with patellar tendonitis resistant to conservative therapy were analysed to identify the characteristic MRI appearance and to determine if the patellar morphology was abnormal. A significant thickening of the tendon was found in all cases; this was a more reliable diagnostic feature than a high signal within the superior posterior and central aspect of the tendon at its proximal attachment The site of the lesion shown by MRI is more compatible with impingement of the inferior pole of the patella against the patellar tendon than a stress overload of the tendon. There were no significant differences in the length of the patella, inferior pole or length of the articular surface when the patellar morphology was compared with that of a matched control group.
The aim of this study was to review the early
outcome of the Femoro-Patella Vialla (FPV) joint replacement. A
total of 48 consecutive FPVs were implanted between December 2007
and June 2011. Case-note analysis was performed to evaluate the
indications, operative histology, operative findings, post-operative
complications and reasons for revision. The mean age of the patients
was 63.3 years (48.2 to 81.0) and the mean follow-up was
25.0 months (6.1 to 48.9). Revision was performed in seven (14.6%)
at a mean of 21.7 months, and there was one re-revision. Persistent
pain was observed in three further patients who remain unrevised.
The reasons for revision were pain due to progressive tibiofemoral
disease in five, inflammatory arthritis in one, and patellar fracture following
trauma in one. No failures were related to the implant or the technique.
Trochlear dysplasia was associated with a significantly lower rate
of revision (5.9% Focal patellofemoral osteoarthritis secondary to trochlear dysplasia
should be considered the best indication for patellofemoral replacement.
Standardised radiological imaging, with MRI to exclude overt tibiofemoral
disease should be part of the pre-operative assessment, especially
for the non-dysplastic knee. Cite this article:
A feasibility study of the use of an MRI based patient specific knee arthroplasty system within the NHS. Introducing new technologies within a public funded health system can be challenging. We assess the use and potential benefit of customised jigs for knee arthroplasty. Outcomes assessed were safety and accuracy of implantation. Eight knee replacements using custom jigs were compared to 11 conventionally instrumented replacements matched to surgeon and operative day. Parameters measured include tourniquet time; drain output; hospital stay; adjusted change in haemoglobin; complications; and component position on post-operative long-leg alignment films None of the parameters observed demonstrated a statistically significant difference from the conventional arthroplasty group. No complications were seen in either group. No significant differences were seen in alignment. Our early experiences show that this technology appears safe and allows accurate implantation of the prosthesis. There was a trend for decreased stay and blood loss. The health economic benefits of navigational arthroplasty have been demonstrated in other studies and come from the lack of instrumentation of the intramedullary canal. MRI based patient specific instrumentation is considered technically easier and more convenient than intra-operative navigation. A larger study is planned to assess the health economic implications of adopting this new technology.
To assess the performance of an acellular synthetic scaffold in the treatment of painful partial meniscal tissue loss. Subjects recruited (n=52) had irreparable medial or lateral meniscus partial meniscus loss, intact rim, presence of both horns and a stable well aligned knee. Diagnostic imaging was used to assess tissue ingrowth at 3 months post-implantation by evidence of vascularisation in the scaffold using DCE-MRI with intravenous gadolinium contrast material (n=42). All DCE-MRI scans were assessed centrally for neovascularisation in the peripheral half of the scaffold meniscus and integration of the implanted device. Stability of tissue ingrowth and cartilage scores in the index compartment were assessed at 12 and 24 months post-implantation using anatomic MRI scans.Purposes of the study
Methods
Abstract. Introduction. Previous research has demonstrated no clinically significant benefit of arthroscopic meniscectomy in patients with a meniscal tear, however, patients included in these studies would not meet current treatment recommendations. Prior to further randomised controlled trials (RCTs) research is needed to understand a younger population in more detail. Aim. To describe the baseline characteristics of patients with a meniscal tear and explore any association between baseline characteristics and outcome. Methodology. A prospective, national multicentre cohort study was performed recruiting patients aged 18 to 55 presenting to secondary care. MRI analysis of arthritis was performed using Whole Organ Magnetic Resonance
Unicompartmental knee arthroplasty (UKA) is the preferred treatment for anterior medial knee osteoarthritis (OA) owing to the rapid postoperative recovery. However, the risk factors for UKA failure remain controversial. The clinical data of Oxford mobile-bearing UKAs performed between 2011 and 2017 with a minimum follow-up of five years were retrospectively analyzed. Demographic, surgical, and follow-up data were collected. The Cox proportional hazards model was used to identify the risk factors that contribute to UKA failure. Kaplan-Meier survival was used to compare the effect of the prosthesis position on UKA survival.Aims
Methods
Patient dissatisfaction is not uncommon following primary total knee arthroplasty. One proposed method to alleviate this is by improving knee kinematics. Therefore, we aimed to answer the following research question: are there significant differences in knee kinematics based on the design of the tibial insert (cruciate-retaining (CR), ultra-congruent (UC), or medial congruent (MC))? Overall, 15 cadaveric knee joints were examined with a CR implant with three different tibial inserts (CR, UC, and MC) using an established knee joint simulator. The effects on coronal alignment, medial and lateral femoral roll back, femorotibial rotation, bony rotations (femur, tibia, and patella), and patellofemoral length ratios were determined.Aims
Methods
Total knee arthroplasty (TKA) is a common and safe orthopaedic procedure. Zimmer Biomet's NexGen is the second most popular brand of implant used in the UK. The primary cause of revision after the first year is aseptic loosening. We present our experience of using this implant, with significant concerns around its performance with regards early aseptic loosening of the tibial component. A retrospective, single-surgeon review was carried out of all of the NexGen Legacy Posterior Stabilized (LPS) TKAs performed in this institute. The specific model used for the index procedures was the NexGen Complete Knee System (Legacy Knee-Posterior Stabilized LPS-Flex Articular Surface, LPS-Flex Femoral Component Option, and Stemmed Nonaugmentable Tibial Component Option).Aims
Methods
Patient specific cutting guides generated by
preoperative Magnetic Resonance
Background. The management of chondral lesions in the knee, especially in young fit patients, remains an area of considerable controversy. Articular cartilage repair or reconstruction techniques may offer these patients alternatives to arthroplasty or realignment osteotomy. The TruFit plug (Smith & Nephew, London, UK) is a synthetic biphasic polymer scaffold that is designed for implantation at the site of a focal chondral defect. It is intended to resorb and allow tissue ingrowth 6-9 months following implantation and may be placed either arthroscopically or via an open approach depending on the site of the lesion. Methods. 11 patients with focal chondral defects in the knee underwent TruFit plug implantation. Postoperative management entailed a period of 6 weeks of restricted weight bearing or restricted knee flexion according to implantation site. Radiological evaluation with MRI or CT arthrogram (or both) was conducted at various time points postoperatively according to clinical indication. Functional scoring with the Oxford knee score (OKS), Tegner activity scale and Lysholm score were completed. Results. 35 TruFit plugs were implanted in 12 knees of 11 patients (4 men, 7 women) between June 2007 and December 2009. Mean age at time of surgery 46.9 years (range32-72years). Mean change in OKS 1.33 (range -13 to 29), Lysholm 13.8 (range -19 to 61), Tegner 0.33 (range -2 to 2 levels).
MRI has been suggested as an objective method of assessing anterior crucate ligament (ACL) graft “ligamentization” after reconstruction. It has been proposed that the MRI appearances could be used as an indicator of graft maturity and used as part of a return-to-sport assessment. The aim of this study was to evaluate the correlation between MRI graft signal and postoperative functional scores, anterior knee laxity, and patient age at operation. A consecutive cohort of 149 patients who had undergone semitendinosus autograft ACL reconstruction, using femoral and tibial adjustable loop fixations, were evaluated retrospectively postoperatively at two years. All underwent MRI analysis of the ACL graft, performed using signal-to-noise quotient (SNQ) and the Howell score. Functional outcome scores (Lysholm, Tegner, International Knee Documentation Committee (IKDC) subjective, and IKDC objective) were obtained and all patients underwent instrumented side-to-side anterior laxity differential laxity testing.Aims
Methods
Introduction. Peri-prosthetic infections due to P. acnes may present as Prosthesis dysfunction without any obvious sepsis. We present our experience of efficient management of total knee prosthesis infection secondary to P. acnes which is one of the biggest case series. Materials and methods. From 2008 to 2009, 9 patients diagnosed with P. acnes infection after knee arthroplasty were retrospectively reviewed and analysed for clinical diagnosis; laboratory data (ESR, CRP); Radiological
The objective of this study is to assess the use of ultrasound (US) as a radiation-free imaging modality to reconstruct 3D anatomy of the knee for use in preoperative templating in knee arthroplasty. Using an US system, which is fitted with an electromagnetic (EM) tracker that is integrated into the US probe, allows 3D tracking of the probe, femur, and tibia. The raw US radiofrequency (RF) signals are acquired and, using real-time signal processing, bone boundaries are extracted. Bone boundaries and the tracking information are fused in a 3D point cloud for the femur and tibia. Using a statistical shaping model, the patient-specific surface is reconstructed by optimizing bone geometry to match the point clouds. An accuracy analysis was conducted for 17 cadavers by comparing the 3D US models with those created using CT. US scans from 15 users were compared in order to examine the effect of operator variability on the output.Aims
Methods
In the last decade, interest in partial knee arthroplasties and bicruciate retaining total knee arthroplasties has increased. In addition, patient-related outcomes and functional results such as range of movement and ambulation may be more promising with less invasive procedures such as bicompartmental arthroplasty (BCA). The purpose of this study is to evaluate clinical and radiological outcomes after a third-generation patellofemoral arthroplasty (PFA) combined with a medial or lateral unicompartmental knee arthroplasty (UKA) at mid- to long-term follow-up. A total of 57 procedures were performed. In 45 cases, a PFA was associated with a medial UKA and, in 12, with a lateral UKA. Patients were followed with validated patient-reported outcome measures (Oxford Knee Score (OKS), EuroQol five-dimension questionnaire (EQ-5D), EuroQoL Visual Analogue Scale (EQ-VAS)), the Knee Society Score (KSS), the Forgotten Joint Score (FJS), and radiological analysis.Aims
Methods
Stiffness is a common complication after total knee arthroplasty (TKA). Pathogenesis is not understood, treatment options are limited, and diagnosis is challenging. The aim of this study was to investigate if MRI can be used to visualize intra-articular scarring in patients with stiff, painful knee arthroplasties. Well-functioning primary TKAs (n = 11), failed non-fibrotic TKAs (n = 5), and patients with a clinical diagnosis of fibrosisAims
Methods
The aim of this study was to compare robotic arm-assisted bi-unicompartmental knee arthroplasty (bi-UKA) with conventional mechanically aligned total knee arthroplasty (TKA) in order to determine the changes in the anatomy of the knee and alignment of the lower limb following surgery. An analysis of 38 patients who underwent TKA and 32 who underwent bi-UKA was performed as a secondary study from a prospective, single-centre, randomized controlled trial. CT imaging was used to measure coronal, sagittal, and axial alignment of the knee preoperatively and at three months postoperatively to determine changes in anatomy that had occurred as a result of the surgery. The hip-knee-ankle angle (HKAA) was also measured to identify any differences between the two groups.Aims
Methods
The Oswestry-Bristol Classification (OBC) was recently described as an MRI-based classification tool for the femoral trochlear. The authors demonstrated better inter- and intraobserver agreement compared to the Dejour classification. As the OBC could potentially provide a very useful MRI-based grading system for trochlear dysplasia, it was the aim to determine the inter- and intraobserver reliability of the classification system from the perspective of the non-founder. Two orthopaedic surgeons independently assessed 50 MRI scans for trochlear dysplasia and classified each according to the OBC. Both observers repeated the assessments after six weeks. The inter- and intraobserver agreement was determined using Cohen’s kappa statistic and S-statistic nominal and linear weights.Aims
Methods