Advertisement for orthosearch.org.uk
Results 1 - 6 of 6
Results per page:
Bone & Joint Open
Vol. 5, Issue 10 | Pages 843 - 850
8 Oct 2024
Greve K Ek S Bartha E Modig K Hedström M

Aims. The primary aim of this study was to compare surgical methods (sliding hip screw (SHS) vs intramedullary nailing (IMN)) for trochanteric hip fracture in relation to death within 120 days after surgery and return to independent living. The secondary aim was to assess whether the associations between surgical method and death or ability to return to independent living varied depending on fracture subtype or other patient characteristics. Methods. A total of 27,530 individuals from the Swedish Hip Fracture Register RIKSHÖFT (SHR) aged ≥ 70 years, admitted to hospital between 1 January 2014 and 31 December 2019 with trochanteric hip fracture, were included. Within this cohort, 12,041 individuals lived independently at baseline, had follow-up information in the SHR, and were thus investigated for return to independent living. Death within 120 days after surgery was analyzed using Cox regression with SHS as reference and adjusted for age and fracture type. Return to independent living was analyzed using logistic regression adjusted for age and fracture type. Analyses were repeated after stratification by fracture type, age, and sex. Results. Overall, 2,171 patients (18%) who were operated with SHS and 2,704 patients (18%) who were operated with IMN died within 120 days after surgery. Adjusted Cox regression revealed no difference in death within 120 days for the whole group (hazard ratio 0.97 (95% CI 0.91 to 1.03)), nor after stratification by fracture type. In total, 3,714 (66%) patients who were operated with SHS and 4,147 (64%) patients who were operated with IMN had returned to independent living at follow-up. There was no significant difference in return to independent living for the whole group (odds ratio 0.95 (95% CI 0.87 to 1.03)), nor after stratification by fracture type. Conclusion. No overall difference was observed in death within 120 days or return to independent living following surgery for trochanteric hip fracture, depending on surgical method (SHS vs IMN) in this recent Swedish cohort, but there was a suggested benefit for SHS in subgroups of patients. Cite this article: Bone Jt Open 2024;5(10):843–850


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_11 | Pages 13 - 13
7 Jun 2023
Diffley T Ferry J Sumarlie R Beshr M Chen B Clement N Farrow L
Full Access

Appropriate surgical management of hip fractures has major clinical and economic consequences. Recently IMN use has increased compared to SHS constructs, despite no clear evidence demonstrating superiority of outcome. We therefore set out to provide further evidence about the clinical and economic implications of implant choice when considering hip fracture fixation strategies. A retrospective cohort study using Scottish hip fracture audit (SHFA) data was performed for the period 2016–2022. Patients ≥50 with a hip fracture and treated with IMN or SHS constructs at Scottish Hospitals were included. Comparative analyses, including adjustment for confounders, were performed utilising Multivariable logistic regression for dichotomous outcomes and Mann-Whitney-U tests for non-parametric data. A sub-group analysis was also performed focusing on AO-A1/A2 configurations which utilised additional regional data. Cost differences in Length of Stay (LOS) were calculated using defined costs from the NHS Scotland Costs book. In all analyses p<0.05 denoted significance. 13638 records were included (72% female). 9867 received a SHS (72%). No significant differences were identified in 30 or 60-day survival (Odds Ratio [OR] 1.05, 95%CI 0.90–1.23; p=0.532), (OR 1.10, 95%CI 0.97–1.24; p=0.138) between SHS and IMN's. There was however a significantly lower early mobilisation rate with IMN vs SHS (OR 0.64, 95%CI 0.59–0.70; p<0.001), and lower likelihood of discharge to domicile by day-30 post-admission (OR 0.77, 95%CI 0.71–0.84; p<0.001). Acute and overall, LOS were significantly lower for SHS vs IMN (11 vs 12 days and 20 vs 24 days respectively; p<0.001). Findings were similar across a sub-group analysis of 559 AO A1/A2 fracture configurations. Differences in LOS potentially increases costs by £1230 per-patient, irrespective of the higher costs of IMN's v SHS. Appropriate SHS use is associated with early mobilisation, reduced LOS and likely with reduced cost of treatment. Further research exploring potential reasons for the identified differences in early mobilisation are warranted


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_12 | Pages 53 - 53
23 Jun 2023
Schemitsch EH Nowak LL De Beer J Brink O Poolman R Mehta S Stengel D Bhandari M
Full Access

We aimed to use data from a randomized controlled trial (RCT) comparing the sliding hip screw vs. intramedullary nailing (IMN) for trochanteric fractures to examine complication rates between those managed with a short vs. long IMN. This is a secondary analysis using one arm of an RCT of patients ≥18 years with trochanteric fractures. We examined differences in fracture-related (femoral shaft fracture, implant failure, surgical site infection (SSI), nonunion, limb shortening, and pain) and medical (organ failure, respiratory distress, stroke, deep vein thrombosis [DVT] gastrointestinal upset, pneumonia, myocardial infarction, sepsis, or urinary tract infection) adverse events (AE), and readmission between short vs. long IMNs. We included 412 trochanteric fracture patients, 339 (82.2%) of whom received a short (170mm–200mm) nail, while 73 (17.7%) received a long (260mm–460 mm) nail. Patients in the long group were more likely to be admitted from home (vs. an institution), and have comorbidities, or more complex fracture types. Patients in the long group had higher rates of fracture-related AE (12.3%) vs. the short group (3.5%). Specifically, SSI (5.5% vs. 0.3%) and pain (2.7% vs. 0.0%) were significantly higher in the long group. Patients in the long group were also more likely to develop DVT (2.7% vs. 0.3%), and be readmitted to the hospital (28.8% vs. 20.7%). Following covariable adjustment, long nails remained associated with a higher odds of fracture-related AE (5.11, 1.96–13.33) compared to short nails. We found no association between the adjusted odds of readmission and nail length (1.00, 0.52–1.94). Our analyses revealed that trochanteric fracture patients managed with long IMN nails may have a higher odds of fracture-related AE compared to short nails. Future research is required to validate these findings with larger event rates, and further optimize IMN for trochanteric fracture patients


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_6 | Pages 51 - 51
2 May 2024
Diffley T Yee T Letham C Ali M Cove R Mohammed I Kindi GA Samara A Cunningham C
Full Access

Extracapsular Hip Fractures (EHF's) are a significant health burden on healthcare services. Optimal treatment is controversial with conflicting evidence being reported. Currently treatment is undertaken with Intramedullary Nail (IMN) or Dynamic Hip Screw (DHS) constructs with a recent increase in IMN use (1). This study aims to conduct a systematic review of Randomised Control Trials published between 2020 and 2023 with particular focus on patient demographics and holistic patient outcomes. Using a unified search-protocol, RCT's published between 2020 and 2023 were collected from CENTRAL, PubMed, MEDLINE and EMBASE. Rayyan software screened duplicates. Using the CASP and Cochrane Risk of Bias Tool papers were critically examined twice, and Blood Loss, Infection and Mobility described the patient journey. Patient demographics were recorded and were contrasted with geographically diverse cohort studies to compare population differences. Parametric tests were used to determine significance levels between population demographics, namely Age and Sex. Eleven papers were included, representing 908 patients (436 Male). The mean age for patients was 64.39. There was considerable risk of bias in 7/11 studies owing to the randomization process and the recording of data. Four Cohort studies were selected for comparison representing 14314 patients. Mean age was significantly different between Cohort Studies and RCT's (Independent T-Test, df 13, t=7.8, p = <0.001, mean difference = 19.251, 95% CI = 13.888, 24.613). This was also true for sex ratios included in the studies (df 13, t = -2.268, p = 0.024, Mean Difference = -0.4884, 95% CI = -0.9702, -0.0066). To conclude, RCT's published in the post COVID-19 era are not representative of patient demographics. This has the potential to provide inaccurate information for implant selection. Additionally further research must be conducted in how to better improve RCT patient inclusion so as to be more representative of patients whilst balancing the risks of operations


Bone & Joint Open
Vol. 5, Issue 2 | Pages 123 - 131
12 Feb 2024
Chen B Duckworth AD Farrow L Xu YJ Clement ND

Aims

This study aimed to determine whether lateral femoral wall thickness (LWT) < 20.5 mm was associated with increased revision risk of intertrochanteric fracture (ITF) of the hip following sliding hip screw (SHS) fixation when the medial calcar was intact. Additionally, the study assessed the association between LWT and patient mortality.

Methods

This retrospective study included ITF patients aged 50 years and over treated with SHS fixation between 2019 and 2021 at a major trauma centre. Demographic information, fracture type, delirium status, American Society of Anesthesiologists grade, and length of stay were collected. LWT and tip apex distance were measured. Revision surgery and mortality were recorded at a mean follow-up of 19.5 months (1.6 to 48). Cox regression was performed to evaluate independent risk factors associated with revision surgery and mortality.


The Bone & Joint Journal
Vol. 98-B, Issue 6 | Pages 747 - 753
1 Jun 2016
Tengberg PT Foss NB Palm H Kallemose T Troelsen A

Aims

We chose unstable extra-capsular hip fractures as our study group because these types of fractures suffer the largest blood loss. We hypothesised that tranexamic acid (TXA) would reduce total blood loss (TBL) in extra-capsular fractures of the hip.

Patients and Methods

A single-centre placebo-controlled double-blinded randomised clinical trial was performed to test the hypothesis on patients undergoing surgery for extra-capsular hip fractures. For reasons outside the control of the investigators, the trial was stopped before reaching the 120 included patients as planned in the protocol.