Aim. To investigate the validity of threshold values for the Oxford
Administration of perioperative antibiotic prophylaxis (AP) reduces the risk of prosthetic joint infection (PJI) following primary total
Ruling out an infection in one-stage
The role of digital radiography has evolved in recent years. In many hospitals, radiographs have been completely digitised and moved to Picture Archiving and Communications System (PACS). Pre-operative templating for arthroplasty has been a major problem as a result. We investigate the accuracy of Orthoview™ software in templating for hip and knee arthroplasty. A retrospective review of 20 Stryker-Exter hip and 20 Biomet-Vanguard knee arthroplasties was conducted. Anonymised preoperative radiographs were reviewed by experienced orthopaedic surgeons. Templated component sizes were compared with actual implanted component sizes. All radiographs were digitised on Kodak Carestream PACS. Five surgeons were asked to separately review the radiographs to avoid intra-observer error. In templating for hip arthroplasty, Orthoview™ was 80% accurate in predicting the femoral stem size within one size of the actual component used. It predicted the offset with 100% accuracy. In 90% of patients, the actual head implant was within one size of the templated head. The system was able to predict the acetabular component size in only 30%. In knee arthroplasty, Orthoview™ was 80% accurate within one size of the actual component used for the femur and 90% for the tibia. Orthoview™ enables the flexibility of digitised films to be used for pre-operative templating. It is reasonably accurate in prediction of femoral sizing in both hip and knee arthroplasty and tibial size in knee arthroplasty. It is considerably less useful for acetabular sizing. Surgeons should keep this variability in mind until more accurate systems are available.
Patient reported outcome measures (PROMs) are important for assessing the results of lower limb arthroplasty. Unrealistic or uneducated expectations may have a significant negative impact on PROMs even when surgery is technically successful. This study's aim was to quantify pre-operative expectations of Scottish patients undergoing total hip and knee replacement (THR/TKR). 100 THR and 100 TKR patients completed validated questionnaires (from the Hospital for Special Surgery) prior to their operation after receiving standard pre-operative information (booklet, DVD, consultations). Each patient rated expectations from very important to not having the expectation. A total score was calculated using a numerical scale for the grading of each expectation. Univariate regression analysis was used to investigate the relationship between demographics and expectation score. The THR cohort had mean age 66.2 (SD 10.5), 53% female, mean BMI 29.0 (SD 5.1) and mean Oxford score 44 (SD 7). The TKR cohort had mean age 67.6 (SD 8.5), 59% female, mean BMI 32.8 (SD 5.8) and mean Oxford score 44 (SD 8). 100% THR and 96% TKR patients had 10 or more expectations of their operation. All expected pain relief. Other improvements expected were: walking for 100% THA and 99% TKA patients; daily activities for 100% THAs and 96% TKAs; recreational activities for 96% THAs and 93% TKAs; sexual activity for 66% THAs and 59% TKAs; psychological well-being for 98% THAs and 91% TKAs. Regression analysis showed increasing age lowered expectations in both THR (p=0.025) and TKR (p=0.031) patients but that gender, BMI and Oxford score were not significantly related to expectations. This study highlights that patients expect far more than pain relief and improved post-operative mobility from their operation. It is important to discuss and manage these expectations with patients prior to surgery. By doing so, patient satisfaction and PROMs should further improve.
To determine differences in knee valgus angles produced during a single leg squat and hip muscle strength between healthy subjects and patients with patellofemoral pain (PFP). To determine correlations between variables of hip muscle strength, knee valgus angle and pain. Study design: Observational study of 20 (8 male 12 female) healthy (H) subjects, matched for age height and weight with 20 (8 male 12 female) PFP patients (mean symptom duration 46.75 weeks). All subjects fulfilled specific inclusion and exclusion criteria. Appropriate Ethical approval was obtained. Measures for both groups were Knee valgus angle during a single leg squat using 2D motion capture and SiliconCoach software for measurement of knee valgus angles, hip abduction, internal and external rotation muscle strength using hand held dynamometry, visual analogue scale for pain. Strength was reported as a percentage of body weight. All measures were taken on the affected leg for PFP subjects and matched for the equivalent leg in healthy group. SiliconCoach was determined to be reliable for intra-rater reliability of knee valgus angle (ICC.996). There were no significant differences in age, height and weight (p=.59,.51,.26 respectively). Significant differences existed in hip abduction strength p=.001(PFP 19.93(9.2), H 32.22(8.26)), Hip internal rotation p=0.001 (PFP 12.94(4.35), H 19.53(6.36)), Hip external rotation p=0.001(PFP 10.00(3.07), H 16.26 (4.62)), Knee Valgus Angles p=0.001(PFP 5.31(2.59), H 2.29 (2.35)). No correlations existed between any of the variables including pain. This preliminary study shows that patients with PFP have larger knee valgus angles when doing a single leg squat and significantly weaker hip muscle strength when compared to healthy subjects. The reason for larger knee angles during single leg squat could be hypothesised as being due to weak hip abductor muscles not sufficiently controlling the alignment of the femur. However no correlations were found for these measures, nor were they found for any of the other variables including pain level. In summary the results indicate that hip musculature strengthening of the rotators and abductors and measures to reduce knee valgus angle should be included in the rehabilitation programme of patients with PFP. Further research with larger numbers of subjects should be developed to investigate this subject.Aim
Results
To investigate if the countermovement jump height differs between ACL injured and uninjured female adolescents and to explore kinematic differences between limbs. Additionally, the association between isometric knee extension strength and jump height was investigated. Thirty-one ACL injured female adolescents (ACLi, 15.3 ± 1.4yrs, 163.9 ± 6.6cm, 63.0 ± 9.3kg) and thirty-eight uninjured (CON, 13.2±1.7yrs, 161.7 ± 8.1cm, 50.6 ± 11.1kg) participated in this study. All participants performed a countermovement jump task, with 3D kinematics collected using a motion analysis system (Vicon, Nexus, Oxford, UK) at 200Hz, and a maximum isometric knee extension task on an isokinetic dynamometer (Biodex Medical Systems, New York, USA) for three trials. The peak torque was extracted from the isometric trials. Independent samples t-test compared the maximum jump height normalised by the dominant leg length between groups, paired samples t-test compared the maximum
Abstract. There are numerous advantages of discharging patients early after any surgery. Day case arthroplasty in
Anterior cruciate ligament reconstruction (ACLR) using a semitendinosus (ST) autograft, with or without gracilis (GR), results in donor muscle atrophy and varied tendon regeneration. The effects of harvesting these muscles on muscle moment arm and torque generating capacity have not been well described. This study aimed to determine between-limb differences (ACLR vs uninjured contralateral) in muscle moment arm and torque generating capacity across a full range of
Fracture related infections (FRI) are debilitating complications of musculoskeletal trauma surgery that can result in permanent functional loss or amputation. This study aims to determine risk factors associated with FRI treatment failure, allowing clinicians to optimise them prior to treatment and identify patients at higher risk. A major trauma centre database was retrospectively reviewed over a six-year period. Of the 102 patients identified with a FRI (66 male, 36 female), 29.4% (n=30) had acute infections (onset <6 weeks post-injury), 34.3% (n=35) had an open fracture. Open fractures were classified using Gustilo-Anderson (GA) classification (type 2:n=6, type 3A:n=16, type 3B:n=10, type 3C:n=3). Patients with periprosthetic infections of the
Several emerging reports suggest an important involvement of the hindfoot alignment in the outcome of knee osteotomy. At present, studies lack a comprehensive overview. Therefore, we aimed to systematically review all biomechanical and clinical studies investigating the role of the hindfoot alignment in the setting of osteotomies around the knee. A systematic literature search was conducted on multiple databases combining “knee osteotomy” and “hindfoot/ankle alignment” search terms. Articles were screened and included according to the PRISMA guidelines. A quality assessment was conducted using the Quality Appraisal for Cadaveric Studies (QUACS) - and modified methodologic index for non-randomized studies (MINORS) scales. Three cadaveric, fourteen retrospective cohort and two case-control studies were eligible for review. Biomechanical hindfoot characteristics were positively affected (n=4), except in rigid subtalar joint (n=1) or talar tilt (n=1) deformity. Patient symptoms and/or radiographic alignment at the level of the hindfoot did also improve after knee osteotomy (n=13), except in case of a small pre-operative lateral distal tibia- and
Pelvic bone defect in patients with severe congenital dysplasia of the hip (CDH) lead to abnormalities in lumbar spine and lower limb alignment that can determine total hip arthroplasty (THA) patients' outcome. These variables may be different in uni- or bilateral CDH. We compared the clinical outcome and the spinopelvic and lower limb radiological changes over time in patients undergoing THA due to uni- or bilateral CHD at a minimum follow-up of five years. Sixty-four patients (77 hips) undergoing THA due to severe CDH between 2006 and 2015 were analyzed: Group 1 consisted of 51 patients with unilateral CDH, and group 2, 113 patients (26 hips) with bilateral CDH. There were 32 females in group 1 and 18 in group 2 (p=0.6). The mean age was 41.6 years in group 1 and 53.6 in group 2 (p<0.001). We compared the
Varus malalignment increases the susceptibility of cartilage to mechanical overloading, which stimulates catabolic metabolism to break down the extracellular matrix and lead to osteoarthritis (OA). The altered mechanical axis from the
Introduction and Objective. Clinically, it is considered that spastic muscles of patients with cerebral palsy (CP) are shortened, and produce higher force in shorter muscle lengths. Yet, direct quantification of spastic muscles’ forces is rare. Remarkably, previous intraoperative tests in which muscle forces are measured directly as a function of joint angle showed for spastic gracilis (GRA) that its passive forces are low, and only a small percentage of its maximum active force is measured in flexed knee positions. However, the relationship of force characteristics of spastic GRA with its muscle-tendon unit length (l. MTU. ) is unknown. Combining intraoperative experiments with participants’ musculoskeletal models developed based on their gait analyses, we aimed to test if spastic GRA muscle (1) operates at short l. MTU. compared to that of typically developing (TD) children, and exerts higher (2) passive and (3) active forces at shorter lengths, within gait-relevant l. MTU. range. Materials and Methods. Ten limbs of seven children with CP (GMFCS-II) were tested. Pre-surgery, gait analyses were conducted. Intraoperatively, isometric spastic GRA distal forces were measured in ten hip-knee joint angle combinations, in two conditions: (i) passive state and (ii) maximal activation of the GRA exclusively. In OpenSim, gait_2392 model was used for each limb to calculate l. MTU. 's per each
Numerous implanted
Background. Spastic muscles of patients with cerebral palsy (CP) are considered structurally as shortened muscles, that produce high force in short muscle lengths. Yet, previous intraoperative studies in which muscles’ forces are measured directly as a function of joint angle showed consistently that spastic knee flexor muscles produce a low percentage of their maximum force in flexed knee positions. They also showed effects of epimuscular myofascial force transmission (EMFT): simultaneous activation of different muscles elevated target muscle's force. However, quantification of spastic muscle's force - muscle-tendon unit length (l. MTU. ) data during gait is lacking. Aim. Combining intraoperative experiments with participants’ musculoskeletal models developed based on their gait analyses, we aimed to test the following hypotheses: activated spastic semitendinosus (ST) muscle (1) operates at short l. MTU. 's during gait, forces are (2) low at short l. MTU. 's and (3) increase by co-activating other muscles. Methods. Ten limbs of seven children with CP (GMFCS-II) were tested. Pre-surgery, gait analyses were conducted. Intraoperatively, isometric spastic ST distal forces were measured in ten hip-knee joint angle combinations, in two conditions: (i) activation of the ST individually and (ii) simultaneously with the gracilis, biceps femoris, and rectus femoris muscles endorsing EMFT. In OpenSim, gait_2392 model was used for each limb to (a) calculate l. MTU. per each
Whilst home-based exercise rehabilitation plays a key role in determining patient outcomes following orthopaedic intervention (e.g. total knee replacement), it is very challenging for clinicians to objectively monitor patient progress, attribute functional improvement (or lack of) to adherence/non-adherence and ultimately prescribe personalised interventions. This research aimed to identify whether 4 knee rehabilitation exercises could be objectively distinguished from each other using lower body inertial measurement units (IMUs) and principle components analysis (PCA) in the hope to facilitate objective home monitoring of exercise rehabilitation. 5 healthy participants performed 4 repetitions of 4 exercises (knee flexion in sitting, knee extension, single leg step down and sit to stand) whilst wearing lower body IMU sensors (Xsens, Holland; sampling at 60 Hz). Anthropometric measurements and a static calibration were combined to create the biomechanical model, with 3D
Introduction. A deep squat (DS) is a challenging motion at the level of the hip joint generating substantial reaction forces (HJRF). During DS, the hip flexion angle approximates the functional range of hip motion. In some hip morphologies this femoroacetabular conflict has been shown to occur as early as 80° of hip flexion. So far in-vivo HJRF measurements have been limited to instrumented hip implants in a limited number of older patients performing incomplete squats (< 50° hip flexion and < 80° knee flexion). Clearly, young adults have a different kinetical profile with