Recently, several smartphone applications (apps) have been developed and validated for ankle ROM measurement tools like the universal
The aim is to investigate if there is a relation between patellar height and knee flexion angle. For this purpose we retrospectively evaluated the radiographs of 500 knees presented for a variety of reasons. We measure knee flexion angle using a computer-generated
Total knee arthroplasty (TKA) aims to alleviate pain and restore joint biomechanics to an equivalent degree to age-matched peers. Zimmer Biomet's Nexgen TKA was the most common implant in the UK between 2003 and 2016. This study compared the biomechanical outcomes of the Nexgen implant against a cohort of healthy older adults to determine whether knee biomechanics is restored post-TKA. Patients with a primary Nexgen TKA and healthy adults >55 years old with no musculoskeletal deficits or diagnosis of arthritis were recruited locally. Eligible participants attended one research appointment. Bilateral knee range of motion (RoM) was assessed with a
Plantar fasciitis (PF) is one of the widespread conditions causing hindfoot pain. The most common presenting symptoms are functional limitation and pain (first step and activity) on plantar surface of the foot. The non-operative treatments provide complete resolution of pain in 90% of patients, but functional limitation still remains as a risk factor for recurrency of PF. Although the number of non-operative treatment options showing efficacy on pain and functional limitation are excessive, the evidences are limited for functional limitation. Additionally, Mulligan mobilization with movement (MMWM) in Chronic Plantar Fasciitis has been poorly studied in the literature. According to these findings, the study was aimed to determine effectiveness of Mulligan mobilization with movement on Chronic Plantar Fasciitis. A total of 25 patients (40 feet) with chronic PF were included in the study. The patients were randomly divided into Mulligan concept rehabilitation group (PF-M, n=20 feet) and Home Rehabilitation group (PF-H, n=20 feet). (MMWM), Foot and ankle exercises program were applied to PF-M, twice a week totally 8 week (16 sessions) and foot- ankle exercises as a home program were given for PF-H, 8 weeks. The range of motion (ROM) for dorsiflexion and plantar flexion was measured by using a manual
Background. Severe hallux rigidus can be treated with total or hemi arthroplasty to preserve motion in the 1st metatarsophalangeal joint (MTPJ). Decreased dorsiflexion impairs the rollover motion of the 1st MTPJ and recent studies of patients with 1st MTPJ osteoarthritis show increased plantar forces on the hallux. Objectives. Our aim was to examine the plantar force variables under the hallux and the 1st, 2nd, and 3rd – 5th distal metatarsal head (MH) on patients operated with a proximal hemiarthroplasty (HemiCap) in the 1st MTPJ and compare to a control group of healthy patients. Secondary aims: To examine correlations between the force and the 1st MTPJ range of motion (ROM) and pain. Study Design & Methods. Seventy patients operated with HemiCap were invited. 41 were included, (10 men, 31 women), median operation date 2011(range 2007–2014), age 63(47–78), 37 unilateral and 4 bilateral. Dorsal ROM of the 1st MTPJ was measured by
Foot pain and related problems are quite common in the community. It is reported that 24% of individuals older than 45 experienced foot pain. Also, it is stated that at least two thirds of individuals experiences moderate physical disability due to foot problems. In the absence of evaluation of risk factors such as limited ankle dorsiflexion in the early period of the diseases (Plantar fasciitis, Achilles Tendinopathy e.g.) and the lack of mobile systems with portable remote access, foot pain becomes refractory/chronic foot pain, secondary pathologies and ends with workload of 1., 2. and 3rd level healthcare services. In the literature, manuel and dijital methods have been used to analyze the ankle range of motion (ROM). These studies are generally based on placing protractors on the image and / or angle detection from inclination measurement by using the gyroscope sensor of the mobile device. Some of these applications are effective and they are designed to be suitable for measuring in a clinical setting by a physician or physiotherapist. To the best of our knowledge, there is no system developed to measure real-time ankle ROM remotely with collaboration of the patients. In this research, we proposed to develop an ankle ROM analyze system with smart phone application that can be used comfortably by subjects. We present a case of a 22-year-old male with a symptomatic pes planus. The mobile application, which was used for data collection, was designed and implemented for Android devices. Initially, before the mobile application home page is opened, a consent page was submitted to the acceptance of individual within the scope of Law (KVKK) data privacy. Then, the participant was asked to state his sociodemographic characteristics [age, gender, height, weight] and dominant side. No history of foot-ankle injury, trauma, and surgery was recorded. Activity pain of the foot was 6 according to visual anolog scale (VAS) in the mobile application. His ankle dorsiflexion was 15 ° by manuel
Background. Non-contact anterior cruciate ligament (ACL) injuries occurs with a higher incidence in female athletes compared with males after the onset of puberty. One anatomical factor with clinically observable differences between males and females is lower extremity alignment. The knee joint valgus in the coronal plane, which is associated with ACL injury risk, is composed of rotation of the tibia around the stationary femur and hip rotation combined with knee flexion. The purpose of this study was to prove the difference of hip rotation between female and male handball players with or without history of ACL injury. Methods. Elite collegiate athletes on the varsity handball team (17 females and 24 males) were recruited. Whereas 8 females and 1 male had a history of ACL injury, there were 9 females and 23 males with no history of ACL injury. The 6 measures of hip joint motion [flexion, extension, abduction, adduction, external rotation (ER), and internal rotation (IR)] and the 2 measures of knee joint motion (flexion and extension) were measured with the standard procedure using a
The management of displaced forearm diaphyseal fractures in adults is predominantly operative. Anatomical reduction is necessary to infer optimal motion and strength. The authors have observed an intraoperative technique where passive pronosupination is examined to assess quality of reduction as a surrogate marker for active movement. We aimed to assess the value of this technique, but intentionally malreducing a simulated diaphyseal fracture of a radius in a cadaveric model, and measuring the effect on pronosupination. A single cadaveric arm was prepared and pronation/supination was examined according to American Academy of Orthopaedic Surgeons guidance. A Henry approach was then performed and a transverse osteotomy achieved in the radial diaphysis. A volar locking plate was used to hold the radius in progressive amounts of translation and rotation, with pronosupaintion measured with a
Summary Statement. The circle theorem is a simple and effective measurement tool for estimating acetabular version after total hip arthroplasty. Introduction. Position of the acetabular cup is a major factor in the range of motion and risk of dislocation after total hip arthroplasty. However, there is no well established technique for accurately and easily estimating acetabular cup version intraoperatively or postoperatively. The objective of this study was to evaluate a recently proposed method for measuring acetabular cup version on a single plain radiograph of the hip, which is based on one of the circle theorems in basic geometry. Patients & Methods. Radiographic version is defined as the angle between the cup face plane and a plane perpendicular to the body coronal plane. Using this definition, a metal hemispheric cup was placed in a pelvic sawbone model at a series of known angles of radiographic version (based on direct
To study the effect of ligament injuries and surgical repair we investigated the three-dimensional kinematics of the ankle joint complex and the talocrural and the subtalar joints in seven fresh-frozen lower legs before and after sectioning and reconstruction of the ligaments. A foot movement simulator produced controlled torque in one plane of movement while allowing unconstrained movement in the remainder. After testing the intact joint the measurements were repeated after simulation of ligament injuries by cutting the anterior talofibular and calcaneofibular ligaments. The tests were repeated after the Evans, Watson-Jones and Chrisman-Snook tenodeses. The range of movement (ROM) was measured using two
There are various pin-in-plaster methods for treating fractures
of the distal radius. The purpose of this study is to introduce
a modified technique of ‘pin in plaster’. Fifty-four patients with fractures of the distal radius were
followed for one year post-operatively. Patients were excluded if
they had type B fractures according to AO classification, multiple
injuries or pathological fractures, and were treated more than seven
days after injury. Range of movement and functional results were
evaluated at three and six months and one and two years post-operatively.
Radiographic parameters including radial inclination, tilt, and
height, were measured pre- and post-operatively.Objectives
Methods
Different calcaneal plates with locked screws were compared in an experimental model of a calcaneal fracture. Four plate models were tested, three with uniaxially-locked screws (Synthes, Newdeal, Darco), and one with polyaxially-locked screws (90° ± 15°) (Rimbus). Synthetic calcanei were osteotomised to create a fracture model and then fixed with the plates and screws. Seven specimens for each plate model were subjected to cyclic loading (preload 20 N, 1000 cycles at 800 N, 0.75 mm/s), and load to failure (0.75 mm/s). During cyclic loading, the plate with polyaxially-locked screws (Rimbus) showed significantly lower displacement in the primary loading direction than the plates with uniaxially-locked screws (mean values of maximum displacement during cyclic loading: Rimbus, 3.13 mm ( The increased stability of a plate with polyaxially-locked screws demonstrated during cyclic loading compared with plates with uniaxially-locked screws may be beneficial for clinical use.
We have investigated the anatomy of the proximal part of the ulna to assess its influence on the use of plates in the management of fractures at this site. We examined 54 specimens from cadavers. The mean varus angulation in the proximal third was 17.5° (11° to 23°) and the mean anterior deviation 4.5° (1° to 14°). These variations must be considered when applying plates to the dorsal surface of the ulna for Monteggia-type fractures. A pre-operative radiograph of the contralateral elbow may also be of value.
The aim of this randomised, controlled