Advertisement for orthosearch.org.uk
Results 1 - 20 of 453
Results per page:
Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_18 | Pages 24 - 24
14 Nov 2024
Petersen ET Linde KN Burvil CCH Rytter S Koppens D Dalsgaard J Hansen TB Stilling M
Full Access

Introduction. Knee osteoarthritis often causes malalignment and altering bone load. This malalignment is corrected during total knee arthroplasty surgery, balancing the ligaments. Nonetheless, preoperative gait patterns may influence postoperative prosthesis load and bone support. Thus, the purpose is to investigate the impact of preoperative gait patterns on postoperative femoral and tibial component migration in total knee arthroplasty. Method. In a prospective cohort study, 66 patients with primary knee osteoarthritis undergoing cemented Persona total knee arthroplasty were assessed. Preoperative knee kinematics was analyzed through dynamic radiostereometry and motion capture, categorizing patients into four homogeneous gait patterns. The four subgroups were labeled as the flexion group (n=20), the abduction (valgus) group (n=17), the anterior drawer group (n=10), and the tibial external rotation group (n=19). The femoral and tibial component migration was measured using static radiostereometry taken supine on the postoperative day (baseline) and 3-, 12-, and 24- months after surgery. Migration was evaluated as maximum total point motion. Result. Of the preoperatively defined four subgroups, the abduction group with a valgus-characterized gait pattern exhibited the highest migration for both the femoral (1.64 mm (CI95% 1.25; 2.03)) and tibial (1.21 mm (CI95% 0.89; 1.53)) components at 24-month follow-up. For the femoral components, the abduction group migrated 0.6 mm (CI95% 0.08; 1.12) more than the external rotation group at 24 months. For the tibial components, the abduction group migrated 0.43 mm (CI95% 0.16; 0.70) more than the external rotation group at 3 months. Furthermore, at 12- and 24-months follow-up the abduction group migrated 0.39 mm (95%CI 0.04; 0.73) and 0.45 mm (95%CI 0.01; 0.89) more than the flexion group, respectively. Conclusion. A preoperative valgus-characterized gait pattern seems to increase femoral and tibial component migration until 2 years of follow-up. This suggests that the implant fixation depends on load distributions originating from specific preoperative gait patterns


Although remnant-preserved ACL reconstruction (ACLR) restores knee joint stability and dampens the problem of acute ACL rupture-induced knee pain, an increasing number of patients still develop post-traumatic osteoarthritis (PTOA) after 10 to 15 years of ACLR. We previously found that remnant-preserved ACLR with concomitant medial and lateral meniscus repair may not prevent cartilage degeneration and weaken muscle strength, while the clinical features of PTOA are not clear. We hypothesized that remnant-preserved ACLR with concomitant medial and lateral meniscus tears is related to early cartilage damage, worse function recovery, patient-reported outcomes (PROs) and delayed duration to return to sports. The aim is to evaluate the remnant-preserved ACLR with complicated meniscal injuries in predicting which patients are at higher risk of osteoarthritic changes, worse function and limited activities after ACLR for 12 months. Human ethical issue was approved by a committee from Xi'an Jiaotong University. 26 young and active patients (24 male, 2 female) with ACL injuries (Sherman type I and II) with concomitant medial and lateral meniscus within 2 months were included from January 2014 to March 2022. The average age of the ACLR+ meniscus repair was 26.77±1.52 (8 right, 5 left) and isolated ACLR control was 31.92±2.61 years old (7 left, 6 right). Remnant-preserved ACLR with a 5- to 6-strand hamstring tendon graft was operated on by the same sports medicine specialists. MRI CUBE-T. 2. scanning with 48 channels was conducted by a professional radiologist. The volume of the ACL graft was created through 3 dimensional MRI model (Mimics 19, Ann Arbor). Anterior Cruciate Ligament OsteoArthritis Score (ACLOAS) was applied to score visible cartilage damage. IKDC 2000 score and VAS were assessed by two blinded researchers. Results were presented as mean± SEM of each group. The cross-sectional area and 3D volume of the ACL graft were greater in the remnant-preserved ACLR+meniscus group compared with isolated ACLR (p=0.01). It showed that ACLR+ meniscus group had early signs of joint damage and delayed meniscus healing regarding ACLOAS compared to control group (p=0.045). MRI CUBE-T. 2. prediction of radiographic cartilage degeneration was not obvious in both groups post remnant-preserved ACLR over 12 months (p>0.05). However, higher VAS scores, lower IKDC scores, and long-last joint swelling were reported in the ACLR+ meniscus repair group at the end of 12 months follow-up. Although remnant-preserved ACLR+ meniscus was able to maintain the restore the knee function, it showed delayed timing (>12 months) to return to play at the pre-injury stage, while no difference between the timing of returning to the normal daily routine of their ACLR knee compared to control (p=0.30). The cost of ACLR+ meniscus (average 10,520.76$) was higher than the control group (6,452.92$, p=0.018). Remnants-preserved ACLR with concomitant injured medial and lateral meniscus repair shows a higher risk of cartilage damage, greater cost, worse functional performance, and longer time for young male patients to return to sports after 12-month follow-up compared to isolated ACLR. Further evidence and long-term follow-up are needed to better understand the association between these results and the risk of development of PTOA in this patient cohort


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_8 | Pages 117 - 117
11 Apr 2023
Roser M Izatt M Labrom R Askin G Little P
Full Access

Anterior vertebral body tethering (AVBT) is a growth modulating procedure used to manage idiopathic scoliosis by applying a flexible tether to the convex surface of the spine in skeletally immature patients. The purpose of this study is to determine the preliminary clinical outcomes for an adolescent patient cohort. 18 patients with scoliosis were selected using a narrow selection criteria to undergo AVBT. Of this cohort, 11 had reached a minimum follow up of 2 years, 4 had reached 18 months, and 3 had reached 6 months. These patients all demonstrated a primary thoracic deformity that was too severe for bracing, were skeletally immature, and were analysed in this preliminary study of coronal plane deformity correction. Using open-source image analysis software (ImageJ, NIH) PA radiographs taken pre-operatively and at regular follow-up visits post-operatively were used to measure the coronal plane deformity of the major and compensatory curves. Pre-operatively, the mean age was 12.0 years (S.D. 10.7 – 13.3), mean Sanders score 2.6 (S.D. 1.8-3.4), all Risser 0 and pre-menarchal, with mean main thoracic Cobb angle of 52° (S.D. 44.2-59.8°). Post-operatively the mean angle decreased to 26.4° (S.D. 18.4-32°) at 1 week, 30.4° (S.D. 21.3-39.6°) at 2 months, 25.7° (S.D. 18.7-32.8°) at 6 months, 27.9° (S.D. 16.2-39.6°) at 12 months, and 36.8° (S.D. 22.6– 51.0°) at 18 months and 38.2° (S.D. 27.6-48.7°) at 2 years. The change in curve at 2 years post-operative was statistically significant (P=0.004). There were 4 tether breakages identified that did not require return to theatre as yet, one patient underwent a posterior spinal instrumented fusion due to curve progression. AVBT is a promising new growth modulation technique for skeletally immature patients with progressive idiopathic scoliosis. This study has demonstrated a reduction in scoliosis severity


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_7 | Pages 63 - 63
4 Apr 2023
Rashid M Cunningham L Walton M Monga P Bale S Trail I
Full Access

The purpose of this study is to report the clinical and radiological outcomes of patients undergoing primary or revision reverse total shoulder arthroplasty using custom 3D printed components to manage severe glenoid bone loss with a minimum of 2-year follow-up. After ethical approval (reference: 17/YH/0318), patients were identified and invited to participate in this observational study. Inclusion criteria included: 1) severe glenoid bone loss necessitating the need for custom implants; 2) patients with definitive glenoid and humeral components implanted more than 2 years prior; 3) ability to comply with patient reported outcome questionnaires. After seeking consent, included patients underwent clinical assessment utilising the Oxford Shoulder Score (OSS), Constant-Murley score, American Shoulder and Elbow Society Score (ASES), and quick Disabilities of the Arm, Shoulder, and Hand Score (quickDASH). Radiographic assessment included AP and axial projections. Patients were invited to attend a CT scan to confirm osseointegration. Statistical analysis utilised included descriptive statistics (mean and standard deviation) and paired t test for parametric data. 3 patients had revision surgery prior to the 2-year follow-up. Of these, 2/3 retained their custom glenoid components. 4 patients declined to participate. 5 patients were deceased at the time of commencement of the study. 21 patients were included in this analysis. The mean follow-up was 36.1 months from surgery (range 22–60.2 months). OSS improved from a mean 16 (SD 9.1) to 36 (SD 11.5) (p < 0.001). Constant-Murley score improved from mean 9 (SD 9.2) to 50 (SD 16.4) (p < 0.001). QuickDASH improved from mean 67 (SD 24) to 26 (SD 27.2) (p = 0.004). ASES improved from mean 28 (SD 24.8) to 70 (SD 23.9) (p = 0.007). Radiographic evaluation demonstrated good osseointegration in all 21 included patients. The utility of custom 3D-printed components for managing severe glenoid bone loss in primary and revision reverse total shoulder arthroplasty yields significant clinical improvements in this complex patient cohort


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_7 | Pages 52 - 52
4 Apr 2023
García-Rey E Saldaña L
Full Access

Pelvic tilt can vary over time due to aging and the possible appearance of sagittal spine disorders. Cup position in total hip arthroplasty (THA) can be influenced due to these changes. We assessed the evolution of pelvic tilt and cup position after THA and the possible appearance of complications for a minimum follow-up of ten years. 343 patients received a THA between 2006 and 2009. All were diagnosed with primary osteoarthritis and their mean age was 63.3 years (range, 56 to 80). 168 were women and 175 men. 250 had no significant lumbar pathology, 76 had significant lumbar pathology and 16 had lumbar fusion. Radiological analysis included sacro-femoral-pubic (SFP), acetabular abduction (AA) and anteversion cup (AV) angles. Measurements were done pre-operatively and at 6 weeks, and at five and ten years post-operatively. Three measurements were recorded and the mean obtained at all intervals. All radiographs were evaluated by the same author, who was not involved in the surgery. There were nine dislocations: six were solved with closed reduction, and three required cup revision. All the mean angles changed over time; the SFP angle from 59.2º to 60º (p=0.249), the AA angle from 44.5º to 46.8º (p=0.218), and the AV angle from 14.7º to 16.2º (p=0.002). The SFP angle was lower in older patients at all intervals (p<0.001). The SFP angle changed from 63.8 to 60.4º in women and from 59.4º to 59.3º in men, from 58.6º to 59.6º (p=0.012). The SFP angle changed from 62.7º to 60.9º in patients without lumbar pathology, from 58.6º to 57.4º in patients with lumbar pathology, and from 57.0º to 56.4º in patients with a lumbar fusion (p=0.919). The SFP cup angle was higher in patients without lumbar pathology than in the other groups (p<0.001), however, it changed more than in patients with lumbar pathology or fusion at ten years after THA (p=0.04). Posterior pelvic tilt changed with aging, influencing the cup position in patients after a THA. Changes due to lumbar pathology could influence the appearance of complications long-term


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_7 | Pages 44 - 44
4 Apr 2023
Knopp B Harris M
Full Access

Our study seeks to determine whether characteristics of radiographs taken post-reduction of a forearm fracture can indicate future risk of refracture or loss of reduction. We hypothesize that reducing forearm fractures too precisely may be counterproductive and provide less benefit than reductions left slightly offset prior to cast immobilization.

We conducted a retrospective review of 1079 pediatric patients treated for forearm fractures between January 2014 and September 2021 in a 327 bed regional medical center. Percent fracture displacement, location, orientation, comminution, fracture line visibility and angle of angulation were determined by AP and lateral radiographs. Percent fracture displacement was derived by: (Displacement of Bone Shafts / Diameter) x 100% = %Fracture Displacement.

Patients treated with closed reduction were reduced from a mean displacement of 29.26±36.18% at an angulation of 22.67±16.57 degrees to 7.88±9.07% displacement and 3.89±6.68 degrees angulation post-reduction. Patients developing complications including a loss of reduction or refracture were found to have post-operative radiographs with a lower percent displacement (0.50±1.12) than those not developing complications (8.65±9.21)(p=0.0580). Post-reduction angulation (p=1.000), average reduction in angulation (p=1.000) and average reduction in displacement percent(p=0.2102) were not significantly associated with development of complications.

Percent displacement of radial shafts was seen to be the most important metric to monitor in post-operative radiographs for patients undergoing closed reduction of a forearm fracture. We theorize a slight displacement provides greater surface area for osteoblastic expansion and callus formation leading to a decreased risk of refracture or loss of reduction. While our sample size precludes our ability to measure the ideal amount of post-reduction displacement for optimal healing, our results demonstrate that some degree of shaft displacement is required for optimal healing conditions.


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_16 | Pages 59 - 59
1 Dec 2021
Vemulapalli KV Kumar KHS Khanduja V
Full Access

Abstract. Purpose. Clinical registries are an important aspect of orthopaedic research in assessing the outcomes of surgical intervention and track medical devices. This study aimed to explore the research methodology available to account for patients lost to follow-up (LTFU) specifically in studies related to arthroscopic intervention and whether the rates of patient LTFU are within the acceptable margins for survey studies. Methods. A scoping review, where a literature search for studies from nine arthroscopy registries, was performed on EMBASE, MEDLINE, and the annual reports of each registry. Inclusion criteria included studies with information on patient-reported outcome measures and being based on nine national registries identified. Exclusion criteria included review articles, conference abstracts, studies not based on registry data, and studies from regional, claims-based, or multi-centre registries. Studies were then divided into categories based on method of LTFU analysis used. Results. Thirty-six articles were identified for the final analysis. Categories for LTFU analysis included dropout analyses (n=10), referencing validation studies (n=12), contacting non-responders (n=4), and sensitivity analyses (n=1). Referencing validation studies was the most common method (n=12). Majority (n=35) of the studies exceeded the recommended maximum rates for LTFU. Conclusions. Most arthroscopy studies have rates of LTFU higher than traditionally acceptable. Therefore, any conclusions drawn from these research papers may not be sufficiently valid or free from non-response bias


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_13 | Pages 17 - 17
1 Nov 2021
Sosio C Sirtori P Ciliberto R Lombardo MDM Mangiavini L Peretti G
Full Access

Introduction and Objective. Kinematic Alignment (KA) is a surgical technique that restores the native knee alignment following Total Knee Arthroplasty (TKA). The association of this technique with a medial pivot implant design (MP) attempts to reestablish the physiological kinematics of the knee. Aim of this study is to analyze the clinical and radiological outcomes of patients undergoing MP-TKA with kinematic alignment, and to assess the effect of the limb alignment and the orientation of the tibial component on the clinical outcomes. Materials and Methods. We retrospectively analyzed 63 patients who underwent kinematic aligned medial pivot TKA from September 2018 to January 2020. Patient-Related Outcomes (PROMs) and radiological measures were collected at baseline, 3 months and 12 months after surgery. Results. We demonstrated a significant improvement in the clinical and functional outcomes starting from 3 months after surgery. This finding was also confirmed at the longest follow-up. The clinical improvement was independent from the limb alignment and from the orientation of the tibial component. The radiological analysis showed that the patient's native limb alignment was restored, and that the joint line orientation maintained the parallelism to the floor when standing. This latter result has a particular relevance, as it may positively influence the outcomes, reducing the risk of wear and mobilization of the implant. Conclusions. The association of kinematic alignment and a medial pivot TKA implant allows for a fast recovery, good clinical and functional outcomes, independently from the final limb alignment and the tibial component orientation


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_2 | Pages 77 - 77
1 Mar 2021
Wang J Roberts S McCarthy H Tins B Gallacher P Richardson J Wright K
Full Access

Abstract. Objectives. Meniscus allograft and synthetic meniscus scaffold (Actifit. ®. ) transplantation have shown promising outcomes for symptoms relief in patients with meniscus deficient knees. Untreated chondral defects can place excessive load onto meniscus transplants and cause early graft failure. We hypothesised that combined ACI and allograft or synthetic meniscus replacement might provide a solution for meniscus deficient individuals with co-existing lesions in cartilage and meniscus. Methods. We retrospectively collected data from 17 patients (16M, 1F, aged 40±9.26) who had ACI and meniscus allograft transplant (MAT), 8 patients (7M, 1F, aged 42±11) who underwent ACI and Actifit. ®. meniscus scaffold replacement. Other baseline data included BMI, pre-operative procedures and cellular transplant data. Patients were assessed by pre-operative, one-year and last follow-up Lysholm score, one-year repair site biopsy, MRI evaluations. Results. In the MAT group, the final post-operative evaluation was 7±4.5 years. The mean pre-operative Lysholm score was 49±17, rose to 66.6±16.4 1 year post-op and dropped to 58±26 at final evaluation. Four of the 17 patients had total knee replacements (TKRs) at average 6.4 years after treatment. In the Actifit. ®. group, the final post-operative assessment was 5.6±2.7years. The pre-operative Lysholm score was 53.7±21.3, increasing to 72.8±15.2 at 1 year and 70.4±27.6 at final clinical follow-up. None of the patients in the Actifit® group had received TKRs. Conclusions. Both MAT and Actifit. ®. groups were effective in improving patients symptoms and knee function according to one-year post-operative assessments. However, the knee function of patients in MAT group dropped at final follow-up, whereas the Actifit® group maintained their knee function. These preliminary findings warrant further investigations, to include more patients and alongside comparisons to ACI alone and allograft/Actifit. ®. alone as comparator groups before accurate conclusions may be drawn on the comparative efficacy of each technique. Declaration of Interest. (b) declare that there is no conflict of interest that could be perceived as prejudicing the impartiality of the research reported:I declare that there is no conflict of interest that could be perceived as prejudicing the impartiality of the research project


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_1 | Pages 23 - 23
2 Jan 2024
Ciatti C Quattrini F Asti C Maniscalco P
Full Access

Previous scientific studies have highlighted how coupling is an important element affecting total hip arthroplasty's survival.

This study aims to evaluate whether metal-on-metal (MOM) coupling could be a statistically significant risk factor.

The data from the regional joint registry (Registro dell'Impiantologia Protesica Ortopedica, RIPO) was used for analysis. The data collection accuracy of this registry was 97.2% in 2017.

We retrospective evaluate all MOM total hip arthroplasties (THAs) implanted in our department between January 01st 2000 and December 31st 2011. We used a control group composed by all other prosthesis implanted in our Department in the same time lapse.

We registered 660 MOM THAs. Mean age of patients was 66.9 years. 603 patients have a >36mm head, while 78 a <36 mm one. Neck modularity was present in half of patients. 676 implants were cementless. We registered 69 revisions, especially due to aseptic mobilization (16 THAs), implant breakage (9 THAs) and periprosthetic fracture (6 THAs).

The MOM THAs overall Kaplan-Meier survival rate was 87.2 at 15 years, and the difference between MOM THAs and other implants two curves is statistically significant (p<0.05). Male sex is a significant risk factors. Further evaluations are in progress to establish the presence of any additional risk factors. We think weight and/or BMI may be included in this category.

Our study confirms the data currently present in the literature regarding a lower survival of metal-on-metal hip prostheses.

The male sex is a statistically significant risk factor (p<0.05), while age, head size and modularity of the prosthetic neck are not statistically significant (p>0.05).

Any new finds will be presented at the congress venue.


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_11 | Pages 36 - 36
1 Dec 2020
Genechten WV Vuylsteke K Martinez PR Swinnen L Verdonk P
Full Access

Autologous micro-fragmented adipose tissue (MFAT) for the treatment of symptomatic knee osteoarthritis (OA) is gaining interest although there is still a lack of supportive data on safety and clinical efficacy. This study primarily aimed to identify patient- and pathology-related parameters to tighten patient selection criteria for future clinical MFAT application. Secondly, the overall (1) therapeutic response rate (TRR), (2) short-term clinical effect, (3) effect durability and (4) therapeutic safety was investigated at a minimal follow-up of 1 year. Sixty-four subjects (91 knees) with symptomatic knee OA (mild-severe on MRI) were enrolled in a prospective single-centre case series. Ethical approval was obtained from the local and academic ethical committee (#B300201733775). After liposuction, the adipose tissue was mechanically processed in a Lipogem® device which eventually produced 6–9cc MFAT. Subjects were clinically assessed by means of the KOOS, NRS, UCLA and EQ-5D at baseline and 1, 3, 6 and 12 months after injection. Adverse events were meticulously recorded. The TRR was defined according to the OMERACT-OARSI criteria. A baseline MRI was scored following the MOAKS system. Paired sample t-tests, independent t-test and Fischer's exact test were applied on appropriate variables. Multiple regression models were fit separately for patient-and pathology-specific factors. Significance level was set at α=0.05. The overall TRR was 66% at 3 months and 50% at 12 months after injection. Subgroup analysis revealed that specifically patients with no-mild bone marrow lesions (BML) had a TRR of 88% at 3 months and 75% at 12 months after MFAT injection. Therapy responders at these timepoints improved with 29.3±14.1 points and 30.8±15.3 points on KOOS pain, while non-responders deteriorated mildly. All clinical scores were significantly higher at follow-up compared to baseline (p<0.05). BMI (factor 0.17, p=0.002) and age (factor −0.48, p=0.048) were prognosticators for the TRR% at 1 month and for absolute KOOS pain improvement at 6 months, respectively. Posterior horn lesions (PHL) in the medial meniscus (p<0.001) and bone marrow lesions (p=0.003) were negative prognosticators for the TRR at respectively 6 and 12 months post-injection. An inflammatory reaction (pain, swelling or stiffness) to MFAT was reported in 79% knees and resolved spontaneously within 16.6±13.5 days after administration. The study showed a durable and satisfying TRR (up to 75% at 1 year in selected patients without BML) and clinical improvement after a single intra-articular injection with autologous MFAT. The availability of an index knee MRI is mandatory to select MFAT patients, preferably with no or mild BML and without PHL of the medial meniscus. High BMI and younger age are associated with better early outcomes. In comparison to other injection therapies such as cortisone, hyaluronic acid and PRP, MFAT appears very attractive with an effect durability of at least 1 year


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_2 | Pages 84 - 84
1 Mar 2021
James C Matthews T
Full Access

Abstract. Background. Lateral and medial epicondylitis, more commonly known as Tennis and Golfer's elbow, can cause chronic pain and significant functional impairment in working-age patients. For patients with refractory epicondylitis, platelet rich plasma (PRP) of which ACP is a type, is commonly used as an alternative to surgical intervention, but its efficacy is unproven. Objective. To assess the mid-term outcomes of ultrasound guided ACP injections for patients with refractory epicondylitis who have failed conventional conservative treatment. Methods. 77 patients who were treated with PRP for refractory epicondylitis were included in the study. The mean age of patients was 50.3 years (range 36–70), with 30% men and 70% women. The Oxford Elbow Score (OES) and progression to surgery were used to assess the mid-term outcomes. Results. The mean follow up duration was 2.1 years (range 1.0 – 4.2). Post-procedure OES was recorded for thirty-three patients, of these, thirty-one patients (94.0%) demonstrated an improvement in their OES at mid-term follow-up compared to their pre-op score. The mean change in OES was +16 (range −7 to +34), 81.8% exhibited a minimally important change (MIC) in OES of greater than 8.2 points. Of all seventy-seven patients, seventeen (22.1%) underwent open release and twenty-seven (35.1%) patients were lost to follow up. Conclusion. Ultrasound guided ACP injections can be an effective treatment for refractory epicondylitis and is likely to prevent the need for surgery. Declaration of Interest. (b) declare that there is no conflict of interest that could be perceived as prejudicing the impartiality of the research reported:I declare that there is no conflict of interest that could be perceived as prejudicing the impartiality of the research project


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_4 | Pages 9 - 9
1 Mar 2021
To K Khan W
Full Access

The current standard of practice following knee arthroplasty is to demonstrate the appropriate alignment of knee replacements using knee radiographs. Recent studies have suggested that standard knee radiographs provide adequate accuracy for tibial prosthesis alignment assessment as compared with long knee view radiographs which are more technically demanding and carry greater radiation exposure. In this study, we aim to address whether alignment measured on standard knee radiographs are reliable and reproducible over time. We examined a cohort of 80 patients 37 male (46%), 43 females (54%), mean age = 68 years) who underwent total knee arthroplasty (TKA). Standard knee anteroposterior radiographs performed within 2 days following surgery were compared to standard knee anteroposterior radiographs taken 1 year following the surgery in patients with well-functioning prosthesis. Tibial prosthesis alignment angles between the longitude of the tibial shaft and the tibial baseplate were calculated using Centricity Enterprise Web V3.0 software. The data was examined using R software. In well-functioning primary knee arthroplasties, tibial prosthesis alignment angles measured in the 1-year follow-up standard view knee radiographs were found to deviate from measurements obtained with the same radiographic specifications in the immediate post-operative period. A significant mean percentage difference was found between the two radiographs. Long knee view radiographs may be required in order to accurately assess tibial prothesis alignment following total knee arthroplasty


The current study aims to compare the clinico radiological outcomes between Non-Fusion Anterior Scoliosis (NFASC) Correction and Posterior Spinal Fusion (PSF) for Lenke 5 curves at 2 years follow up. Methods:38 consecutive Lenke 5 AIS patients treated by a single surgeon with NFASC (group A) or PSF (group B) were matched by age, Cobb's angle, and skeletal maturity. Intraoperative blood loss, operative time, LOS, coronal Cobbs, and SRS22 scores at 2 years were compared. Flexibility was assessed by modified Schober's test. Continuous variables were compared using student t-tests and categorical variables were compared using chi-square. The cohort included 19 patients each in group A and B . Group A had M:F distribution of 1:18 while group B had 2:17. The mean age in group A and group B were 14.8±2.9 and 15.3±3.1 years respectively. The mean follow-up of patients in groups A and B were 24.5±1.8 months and 27.4±2.1 months respectively. Mean pre-op thoracolumbar/lumbar (TL/L) cobbs for group A and group B were 55°±7° and 57.5°±8° respectively. At two years follow up, the cobbs for group A and B were 18.2°±3.6° and 17.6°±3.5° respectively (p=0.09). The average operating time for groups A and B were 169±14.2 mins and 219±20.5 mins respectively (p<0.05). The average blood loss of groups A and B were 105.3±15.4 and 325.3±120.4 respectively (p<0.05). The average number of instrumented vertebra between groups A and B were 6.2 and 8.5 respectively (p<0.05). The average LOS for NFASC and PSF was 3.3±0.9 days and 4.3±1.1 days respectively (p<0.05). No statistically significant difference in SRS 22 score was noted between the two groups. No complications were recorded. Our study shows no significant difference in PSF and NFASC in terms of Cobbs correction and SRS scores, but the NFASC group had significantly reduced blood loss, operative time, and fewer instrumented levels. NFASC is an effective alternative technique to fusion to correct and stabilize Lenke 5 AIS curves with preservation of spinal motion


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_15 | Pages 66 - 66
1 Nov 2018
Jethwa KR Abdelhaq A Sanghrajka AP
Full Access

Supracondylar fractures of the humerus (SCFH) are the most common type of paediatric elbow fractures. Due to beliefs that non-operatively managed SCFH may displace further from the original position, they are monitored with repeated radiographs and a large number are unnecessarily surgically pinned. Very limited evidence currently exists to support these beliefs. This study aimed to determine the incidence of late “significant” displacement (requiring surgical management) of non-operatively managed paediatric SCFH, and whether they necessitate close radiographic follow-up. Patients aged ≤16, with a SCFH, were included in this retrospective cohort study. All were initially managed non-operatively with at least one follow-up radiograph within six weeks of injury. Data from four consecutive years (2013–2016) was collected using the hospital's radiology database. Two observers independently analysed patient radiographs and classified fractures by the Gartland and AO systems. The incidence of late displacement was determined using follow-up radiographs and clinic notes. Of the 164 patients included in the study, one patient (Gartland Type II, AO Type III) suffered late displacement at two weeks, requiring surgical fixation. One further patient (AO Type II) had a persistent cubitus varus deformity (Baumann's angle 90°), with no long-term functional deficit. Incidence of late displacement was 0.6% (n=1). Our findings suggest that stable Gartland Type I/AO Type I and II fractures do not require repeated radiographic follow-up. However, some Gartland Type II/AO Type III fractures require monitoring. This could considerably reduce the financial costs for the healthcare system, and inconvenience to families, associated with repeated follow-ups


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_4 | Pages 52 - 52
1 Mar 2021
Harris A O'Grady C Sensiba P Vandenneucker H Huang B Cates H Christen B Hur J Marra D Malcorps J Kopjar B
Full Access

Patients ≤ 55 years have a high primary TKA revision rate compared to patients >55 years. Guided motion knee devices are commonly used in younger patients yet outcomes remain unknown. In this sub-group analysis of a large multicenter study, 254 TKAs with a second-generation guided motion knee implant were performed between 2011–2017 in 202 patients ≤ 55 years at seven US and three European sites. Revision rates were compared with Australian Joint Registry (AOANJRR) 2017 data. Average age 49.7 (range 18–54); 56.4% females; average BMI 34 kg/m2; 67.1% obese; patellae resurfaced in 98.4%. Average follow-up 4.2 years; longest follow-up six years; 27.5% followed-up for ≥ five years. Of eight revisions: total revision (one), tibial plate replacements (three), tibial insert exchanges (four). One tibial plate revision re-revised to total revision. Revision indications were mechanical loosening (n=2), infection (n=3), peri-prosthetic fracture (n=1), and instability (n=2). The Kaplan-Meier revision estimate was 3.4% (95% C.I. 1.7% to 6.7%) at five years compared to AOANJRR rate of 6.9%. There was no differential risk by sex. The revision rate of the second-generation guided motion knee system is lower in younger patients compared to registry controls


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_4 | Pages 10 - 10
1 Mar 2021
To K Khan W Marway P
Full Access

Companies manufacturing total knee arthroplasty (TKA) prostheses produce a variety of tibial and femoral components of different dimensions denoted by numbers or letters. Surgeons frequently implant components that are compatible but not of the same size on the femur and tibia. Recent studies suggest that equally sized femoral and tibial components produce better outcomes compared to size-mismatched components. In our study, we aim to explore the relationship between component size and outcome measured by oxford knee score at six weeks and one year following TKA.

A cohort of twenty-four patients who underwent TKA and had well-functioning prosthesis were studied. Thirteen (54%) had equally sized TKA components implanted, seventy-four patients (42%) had components that were mismatched by one size, and one (4%) had components that were mismatched by more than one size. The Oxford Knee Score (OKS) obtained preoperatively, at six weeks and one year postoperatively were retrieved from an electronic database. All data were analysed using R software.

A significant improvement in pre-operative and one-year postoperative OKS was observed. Patients who received one-size mismatched tibial and femoral components demonstrated a less pronounced improvement in OKS as compared with patients who received equally sized components.

When possible, it may be best to utilise equally sized prosthetic tibial and femoral components when performing total knee arthroplasty. Manufacturers may be able to produce better patient outcomes by including prostheses that are between sizes as part of their production line.


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_13 | Pages 73 - 73
1 Nov 2021
Camera A Tedino R Cattaneo G Capuzzo A Biggi S Tornago S
Full Access

Introduction and Objective

A proper restoration of hip biomechanics is fundamental to achieve satisfactory outcomes after total hip arthroplasty (THA). A global hip offset (GO) postoperatively reduction of more than 5 mm was known to impair hip functionality after THA. This study aimed to verify the restoration of the GO radiographic parameter after primary THA by the use of a cementless femoral stem available in three different offset options without length changing.

Materials and Methods

From a consecutive series of 201 patients (201 hips) underwent primary cementless THA in our centre with a minimum 3-year follow up, 80 patients (80 hips) were available for complete radiographic evaluation for GO and limb length (LL) and clinical evaluation with Harris hip score (HHS). All patients received the same femoral stem with three different offset options (option A with – 5 mm offset, option B and option C with + 5 mm offset, constant for each sizes) without changing stem length.


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_11 | Pages 273 - 273
1 Jul 2014
Alizadehkhaiyat O Vishwanathan K Frostick S
Full Access

Summary Statement. Discovery system produced effective functional improvement in both primary and revision total elbow replacement. The incidence of major complications was in an acceptable range. Introduction. The search for the ideal elbow prosthesis continues as instability and loosening remain the prime reasons for total elbow replacement (TER) failure. The Discovery Elbow System (Biomet) is one of the latest generations of linked prosthesis and has been used in UK since 2003. We report outcome of TER using this system. Methods. A total of 100 TERs (75 primary, 25 revisions) were performed between 2003 and 2010. The main primary underlying pathologies for TER were advanced rheumatoid arthritis (N=58), osteoarthritis (N=35), acute fractures (N=7). There were 60 female and 40 male patients with an average age of 62 years. The outcome assessment included pain, patient satisfaction, Liverpool Elbow Score (LES), range of movement, and imaging during a mean follow-up period of 48.5 months. Major complications are also reported. Results. For the whole patient group (primary + revision), the LES was significantly (p<0.001) improved from 3.79+/−1.71 to 6.36+/−1.85There were significant improvements in elbow flexion from 100°+/−24 to 118°+17, supination from 38°+/−26 to 50°+/−25 and pronation from 48°+/−22 to 61°+/−21. Mean improvement in flexion-extension and pronation-supination arc was 20° and 25°, respectively. 64% of cases were completely pain-free and at the final follow-up (compared to 7% preoperatively). Only 6% of patients scored “Not Satisfied” at the final follow-up. LES improvement was significantly higher in the primary TER compared to revision TER (p<0.05). Imaging reviewed for 60 cases showed loosening in 4% of patients. Other main complications included deep infection (N=2), ulnar neuropathy (N=3), pre-prosthetic fracture (N=2), and prosthetic failure (N=1). Discussion. TER using the Discovery Elbow System is an effective arthroplasty in terms of functional improvement, pain relief and range of motion in both primary and revision patients. TER resulted in no/mild pain in 78% of cases. Patients undergoing Acclaim, Souter-Strathclyde, GSB III, and Coonrad-Morrey TER have been reported to have no/mild pain in 64%, 67%, 50–92% and 60–100% of cases, respectively. A 20° improvement in flexion-extension arc is comparable to that of Acclaim (23°), Souter-Strathclyde (15°), GSBIII (19–33°), and Coonrad-Morrey (17–26°) TER. An improvement of 25° in pronation-supination arc in our series is also comparable to that of 21–28° reported the Coonrad-Morrey and 27–33° for Discovery prostheses. An infection rate of 2% is lower than several other reports for GSB III TER (7–11%) and Coonrad-Morrey (6–8%). The incidence of persistent ulnar neuropathy (3%) was lower compared to GSBIII TER (11–14%), Coonrad-Morrey (12–26%), and Acclaim (8%)


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_30 | Pages 39 - 39
1 Aug 2013
Baird E Macdonald D Gilmour A Kumar C
Full Access

We aimed to review the outcome of Agility total ankle replacements carried out in our institution between 2002 and 2006. Follow-up consisted of clinical and radiological review pre-operatively, then at 6 weeks, 6 and 12 months, and annually until 10 years post op. Clinical review included the American Orthopaedic Foot and Ankle Score, satisfaction and pain scores. Case notes were reviewed to determine intra and post-operative complications. 30 arthroplasties were performed in 30 consecutive patients. Pre-operative diagnosis was rheumatoid arthritis(16), primary osteoarthritis(12) and post-traumatic osteoarthritis(2). After a mean follow up of 6.2 years (1.4–10.1), 4 patients had died, and 22 out of the remaining 24 were available for follow-up. Intra operative complications included lateral malleoli fracture(3) and superficial peroneal nerve injury(2). Post operative complications included 1 early death, but this was not related to the surgical procedure. Two patients developed deep infections of the prosthesis. One underwent removal of the implant; the other is on long term oral antibiotic therapy. One patient had delayed union of the syndesmosis and six patients had non-union. On clinical assessment, patients' AOFAS scores improved from mean 40.4 pre-op to 83.5 post-op (p<0.001). Radiological assessment of the tibial component revealed 25 (93%) patients had lucency in at least one zone in the AP radiograph. We found a relatively high level of re-surgery and complications following Agility total ankle replacement. A 7% revision rate is much higher than would be tolerated in knee or hip arthroplasty, but compares favourably to other studies of TAR. Despite radiological features which suggest loosening, the high rate of re-surgery and complications; patients are generally satisfied with the procedure, reporting lower levels of pain and improved function. Overall we feel that the Agility ankle is an acceptable alternative to ankle arthrodesis, however patients need to be warned of the risk of re-surgery