Advertisement for orthosearch.org.uk
Results 1 - 20 of 1444
Results per page:
The Bone & Joint Journal
Vol. 102-B, Issue 7 Supple B | Pages 85 - 89
1 Jul 2020
Barrack TN Abu-Amer W Schwabe MT Adelani MA Clohisy JC Nunley RM Lawrie CM

Aims. Routine surveillance of primary hip and knee arthroplasties has traditionally been performed with office follow-up visits at one year postoperatively. The value of these visits is unclear. The present study aims to determine the utility and burden of routine clinical follow-up at one year after primary arthroplasty to patients and providers. Methods. All patients (473) who underwent primary total hip (280), hip resurfacing (eight), total knee (179), and unicompartmental knee arthroplasty (six) over a nine-month period at a single institution were identified from an institutional registry. Patients were prompted to attend their routine one-year postoperative visit by a single telephone reminder. Patients and surgeons were given questionnaires at the one-year postoperative visit, defined as a clinical encounter occurring at nine to 15 months from the date of surgery, regarding value of the visit. Results. Compliance with routine follow-up at one year was 35%. The response rate was over 80% for all questions in the patient and clinician surveys. Overall, 75% of the visits were for routine surveillance. Patients reported high satisfaction with their visits despite the general time for attendance, including travel, being over four hours. Surgeons found the visits more worthwhile when issues were identified or problems were addressed. Conclusion. Patient compliance with follow-up at one year postoperatively after primary hip and knee is low. Routine visits of asymptomatic patients deliver little practical value and represent a large time and cost burden for patients and surgeons. Remote strategies should be considered for routine postoperative surveillance primary hip and knee arthroplasties beyond the acute postoperative period. Cite this article: Bone Joint J 2020;102-B(7 Supple B):85–89


The Bone & Joint Journal
Vol. 102-B, Issue 7 | Pages 832 - 837
1 Jul 2020
Dover C Kuiper JH Craig P Shaylor P

Aims. We have previously demonstrated raised cobalt and chromium levels in patients with larger diameter femoral heads, following metal-on-polyethylene uncemented total hip arthroplasty. Further data have been collected, to see whether these associations have altered with time and to determine the long-term implications for these patients and our practice. Methods. Patients from our previous study who underwent Trident-Accolade primary total hip arthroplasties using a metal-on-polyethylene bearing in 2009 were reviewed. Patients were invited to have their cobalt and chromium levels retested, and were provided an Oxford Hip Score. Serum ion levels were then compared between groups (28 mm, 36 mm, and 40 mm heads) and over time. Results. Metal ion levels were repeated in 33 patients. When comparing the results of serum metal ion levels over time, regardless of head size, there was a significant increase in both cobalt and chromium levels (p < 0.001). Two patients with larger head sizes had undergone revision arthroplasty with evidence of trunnion damage at surgery. Two patients within the 40 mm subgroup had metal ion levels above the MHRA (Medicines and Healthcare Products Regulatory Agency) threshold for detailed investigation. The increase in cobalt and chromium, when comparing the 36 mm and 40 mm groups with those of the 28 mm group, was not significant (36 mm vs 28 mm; p = 0.092/p = 0.191; 40 mm vs 28 mm; p = 0.200/p = 0.091, respectively). There was no difference, between femoral head sizes, when comparing outcome as measured by the Oxford Hip Score. Conclusion. This study shows an increase in cobalt and chromium levels over time for all modular femoral head sizes in patients with metal-on-polyethylene bearings, with two patients demonstrating ion levels above the MHRA threshold for failure, and a further two patients requiring revision surgery. These results may have clinical implications regarding longer term follow-up of patients and future implant choice, particularly among younger patients. Cite this article: Bone Joint J 2020;102-B(7):832–837


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_12 | Pages 12 - 12
23 Jun 2023
Yee AHF Chan VWK Chiu K
Full Access

Uncemented femoral components have been used in total hip arthroplasties (THAs) for over three decades. Data on long-term performance of hydroxyapatite-coated femoral stems is however limited. This study reports the survivorship of a collarless, straight, hydroxyapatite-coated femoral stem (Omnifit HA, Osteonic) with a minimum of 20 years of follow-up. We reviewed the results of 165 THAs using Omnifit HA in 138 patients performed between August 1993 and December 1999. The mean age at surgery was 46 years (range 20 – 77 years). Avascular necrosis was the most common cause of THA, followed by ankylosing spondylitis and primary osteoarthritis. The mean follow-up was 22 years (range 20–31 years). At 20 and 25 years, 113 arthroplasties (91 patients) and 63 arthroplasties (55 patients) were available for follow-up respectively, while others had deceased or were lost to follow-up. Kaplan-Meier survivorship analysis was performed to evaluate the survival of the femoral component. Radiographs were reviewed at regular intervals, and implant stability was evaluated using Engh classification. Seven out of 165 stems were revised upon the latest follow-up; that included one case of aseptic loosening with revision done at 15 years, three peri-prosthetic fractures, two infections, and one recurrent dislocation. At 20 years, survivorship with revision of the femoral stem for any cause and aseptic loosening as the endpoint was 96.0% (95% CI, 92.6 – 99.5%) and 98.4% (95% CI, 96.2 – 100%) respectively. At 25 years, the corresponding survivorship rates were 94.5% (95% CI, 91.9 – 97.3%) and 98.1% (95% CI, 95.7 – 99.6%) respectively. Radiographic findings of stable bony fixation were seen in 86 stems (76.1%) and those of loosening in 4 stems (3.5%) at 20 years. All patients with radiographic signs of loosening were asymptomatic and did not require revision. The Omnifit HA femoral stem offered promising long-term survivorship into the third decade


Bone & Joint Open
Vol. 4, Issue 2 | Pages 79 - 86
10 Feb 2023
McLaughlin JR Johnson MA Lee KR

Aims. The purpose of this study is to report our updated results at a minimum follow-up of 30 years using a first generation uncemented tapered femoral component in primary total hip arthroplasty (THA). Methods. The original cohort consisted of 145 consecutive THAs performed by a single surgeon in 138 patients. A total of 37 patients (40 hips) survived a minimum of 30 years, and are the focus of this review. The femoral component used in all cases was a first-generation Taperloc with a non-modular 28 mm femoral head. Clinical follow-up at a minimum of 30 years was obtained on every living patient. Radiological follow-up at 30 years was obtained on all but four. Results. Seven femoral components (18%) required revision, and none for septic loosening. Four well fixed stems were removed during acetabular revision and three were revised for late infection. One femoral component (3%) was loose by radiological criteria. The mean Harris Hip Score improved from 47 points (SD 4.62) preoperatively to 83 points (SD 9.27) at final follow-up. With revision for any reason as the endpoint, survival of the femoral component was 80% (95% confidence interval (CI) 61% to 90%) at 32 years. With revision for aseptic loosing femoral component, survival was 99% (95% CI 93% to 99%). Conclusion. With regards to aseptic loosening, the Taperloc femoral component provides excellent fixation at a mean follow-up of 32 years. Cite this article: Bone Jt Open 2023;4(2):79–86


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_12 | Pages 60 - 60
23 Jun 2023
Yasunaga Y Ohshima S Shoji T Adachi N
Full Access

Satisfactory intermediate and long-term results of rotational acetabular osteotomy (RAO) for the treatment of early osteoarthritis secondary to developmental dysplasia of the hip have been reported. The purpose of this study is to examine the 30-year results of RAO. Between 1987 and 1994, we treated 49 patients (55 hips) with RAO for diagnosis of pre- OA or early-stage OA. Of those patients, 35 patients (43 hips) were available at a minimum of 28 years. The follow-up rate was 78.2% and the mean follow-up was 30.5 years. The mean age at the time of surgery was 34 years. Clinical evaluation was performed with the Merle d'Aubigne and Postel rating scale, and radiographic analyses included measurements of the center-edge angle, acetabular roof angle, and head lateralization index on preoperative, postoperative AP radiographs of the pelvis. Postoperative joint congruency was classified into four grades. The radiographic evidence of progression of OA was defined as the minimum joint space less than 2.5mm. The mean preoperative clinical score was 14.0, which improved to a mean of 15.3 at the time of the latest follow-up. The mean center-edge angle improved from 0.6° preoperatively to 34° postoperatively, the mean acetabular roof angle improved from 28.4°preoperatively to 1.0°postoperatively, the mean head lateralization index improved from 0.642 preoperatively to 0.59 postoperatively. Postoperative joint congruency was excellent in 11 hips, good in 29 hips, and fair in 3 hips. Nineteen patients (20 hips) had radiographic OA progression, and 10 patients (11 hips) were converted to THA. Kaplan-Meier survivorship analysis, with radiographic OA progression as the end point, predicted survival of 75.6% at 20 years and 48.8% at 30 years, and with THA conversion as the end point, 90.2% at 20 years and 71.2% at 30 years. The RAO is an effective surgical procedure for symptomatic dysplastic hips of pre- and early-stage OA and could change the natural history of the dysplastic hip


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_16 | Pages 65 - 65
19 Aug 2024
Walter W Lin D Weinrauch P de Smet K Beaule P Young D Xu J Manktelow A
Full Access

Hip resurfacing arthroplasty (HRA) is a bone conserving alternative to total hip arthroplasty. We present the early 2-year clinical and radiographic follow-up of a novel ceramic-on-ceramic (CoC) HRA in an international multi-centric cohort. Patients undergoing HRA between September 2018 and January 2021 were prospectively included. Patient-reported outcome measures (PROMS) in the form of the Forgotten Joint Score (FJS), HOOS Jr, WOMAC, Oxford Hip Score (OHS) and UCLA Activity Score were collected preoperatively and at 1- and 2-years post-operation. Serial radiographs were assessed for migration, component alignment, evidence of osteolysis/loosening and heterotopic ossification formation. 200 patients were identified to have reached 2-year follow-up. Of these, 185 completed PROMS follow-up at 2 years. There was significant improvement in HOOS (p< 0.001) and OHS (p< 0.001) and FJS (p< 0.001) between the pre-operative and 2-year outcomes. Patients reported improved pain (p<0.001), function (p<0.001) and reduced stiffness (p<0.001) as measured by the WOMAC score. Patients had improved activity scores on the UCLA Active Score (P<0.001) with 53% reporting return to impact activity at 2 years. There was no osteolysis and the mean acetabular cup inclination angle was 41deg and the femoral component shaft angle was 137deg. No fractures were reported over but there was one sciatic nerve palsy with partial recovery. Two patients were revised; one at 3 months for pain due to a misdiagnosed back problem and another at 33 months for loosening of the acetabular component with delamination of the titanium ingrowth surface. CoC resurfacing at 2-years post-operation demonstrate promising results with satisfactory PROMS


The Paprosky acetabular bone defect classification system and related algorithms for acetabular reconstruction cannot properly guide cementless acetabular reconstruction in the presence of porous metal augments. We aimed to introduce a rim, points, and column (RPC)-oriented cementless acetabular reconstruction algorithm and its clinical and radiographic outcomes. A total of 123 patients (128 hips) were enrolled. A minimum 5-year radiographic follow-up was available for 96 (75.8%) hips. The mean clinical and radiographic follow-up durations were 6.8±0.9 (range: 5.2–9.2) and 6.3±1.9 (range: 5.0–9.2) years, respectively. Harris hip score (HHS) improved significantly from 35.39±9.91 preoperatively to 85.98±12.81 postoperatively (P<0.001). Among the fixation modes, 42 (32.8%) hips were reconstructed with rim fixation, 42 (32.8%) with three-point fixation without point reconstruction, 40 (31.3%) with three-point fixation combined with point reconstruction, and 4 (3.1%) with three-point fixation combined with pelvic distraction. Complementary medial wall reconstruction was performed in 20 (15.6%) patients. All acetabular components were radiographically stable. Nine-year cumulative Kaplan–Meier survival rates for 123 patients with the endpoint defined as periprosthetic joint infection, any reoperation, and dissatisfaction were 96.91% (confidence interval [CI]: 86.26%, 99.34%), 97.66% (CI: 92.91%, 99.24%), and 96.06% (CI: 86.4%, 98.89%), respectively. Cup stability in cementless acetabular reconstruction depends on rim or three-point fixation. The continuity of the anterior and posterior columns determines whether the points provide adequate stability to the cup. Medial wall reconstruction is an important complementary fixation method for rim or three-point fixation. The patients who underwent cementless acetabular reconstruction guided by the RPC decision-making algorithm demonstrated satisfactory mid-term clinical function, satisfaction levels, radiographic results, and complication rates


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_16 | Pages 60 - 60
19 Aug 2024
Lau LCM Cheung MH Ng FY Fu H Chan PK Chiu P
Full Access

In total hip arthroplasty (THA), cementless cup without screw holes has the putative benefits of maximizing host bone contact and reducing osteolysis by eliminating channels to backside wear particles. However, supplemental trans-acetabular screws cannot be used. 74 hips in 60 patients receiving same model of cementless cup without screw holes (Depuy Duraloc 100 HA cup) from 6/1999 to 3/2003 were prospectively followed up. All patients were allowed to have immediate full weight bearing. Age at THA was 53 ± 13 (range 24–74) years. Osteonecrosis was the leading hip disease (45% of hips). Survivorship was assessed using revision of the cup as the end point. Radiological parameters, including lateral opening angle, vertical and horizontal migration distances of the cups were measured. Paired t-test was used to compare between the measurements in early postoperative period and at final follow up. 51 hips were assessed at minimum 20 years follow-up. The mean follow-up was 22.6 (range 21 – 25) years. All the cups were well fixed. There were two cup revisions. Conventional polyethylene (PE) was used in both hips; osteolysis occurred 17 and 18 years later. Both cups were well fixed but were revised, one due to cup mal-positioning, one due to need in upsizing the articulation. 14 other hips were revised but these cups were well fixed and not revised; 9 loosened stems (most were cemented Elite plus stems), 5 PE wear and osteolysis (all were conventional PE). At 20 years, the survivorship of cups was 96.1%. Changes in lateral opening angle, vertical and horizontal migration distances were 0.44±1.59°, 0.01±1.52mm and -0.32±1.47mm respectively, without statistical significance. This study provided evidence of excellent long-term survivorship of cementless cup without screw holes. Immediate postoperative weight-bearing also did not lead to cup migration in the long-term


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_12 | Pages 13 - 13
23 Jun 2023
Furnes O Lygre SHL Hallan G Fenstad AM
Full Access

The Norwegian Arthroplasty Register (NAR) started collecting data on total hip arthroplasty (THA) in 1987. Very long-term results of implants for THA are scarce. We aimed to show long-term results for the three most used femoral stems, operated from 1987. We included the uncemented Corail femoral stem (n=66,309) and the cemented Exeter stem (n=35,050) both of which are currently in frequent use. In addition, we included the Charnley stem (n=32,578, in use until 2014). To ensure comparable conditions, stems fixated with low viscosity cement and stems revised due to infections were excluded. Differences in risk of revision (all reasons and stem revisions) were assessed with Kaplan-Meier and Cox regression analyses with adjustment for possible confounding from age, sex and diagnosis (OA, other). Stem revision was defined as a revision caused by loosening of the stem, dislocation, osteolysis in the femur, or periprosthetic femur fracture, and in which the femoral component was removed or exchanged. The median and max follow-up for Corail, Exeter and Charnley were 6.3 (33.1), 8.0 (34.2) and 13.1 (34.3) respectively. Thirty years survival estimates for Corail, Exeter and Charnley stems were 88.6% (CI:85.8–90.9%), 86.7% (83.7–89.2%) and 87.1% (85.4–88.5%) respectively with stem revision as endpoint, and 56.1% (CI:53.1–59.1%), 73.3% (70.5–76.1%) and 80.2% (78.4–82.0%) with all THA revisions as endpoint. Compared to the Corail, the Exeter (HRR=1.3, CI:1.2–1.4) and the Charnley (HRR=1.9, CI:1.7–2.1) had a significant higher risk of stem revision. Women 75 years and older had better results with the cemented stems. Analyses accounting for competing risk from other causes of revision did not alter the findings. The uncemented Corail stem performed well in terms of stem revisions for stem-related revision causes compared to two frequently used cemented stems with very long follow-up. The differences between the three stems were small


Bone & Joint Open
Vol. 2, Issue 1 | Pages 33 - 39
14 Jan 2021
McLaughlin JR Lee KR Johnson MA

Aims. We present the clinical and radiological results at a minimum follow-up of 20 years using a second-generation uncemented total hip arthroplasty (THA). These results are compared to our previously published results using a first-generation hip arthroplasty followed for 20 years. Methods. A total of 62 uncemented THAs in 60 patients were performed between 1993 and 1994. The titanium femoral component used in all cases was a Taperloc with a reduced distal stem. The acetabular component was a fully porous coated threaded hemispheric titanium shell (T-Tap ST). The outcome of every femoral and acetabular component with regard to retention or revision was determined for all 62 THAs. Complete clinical follow-up at a minimum of 20 years was obtained on every living patient. Radiological follow-up was obtained on all but one. Results. Two femoral components (3.2%) required revision. One stem was revised secondary to a periprosthetic fracture one year postoperatively and one was revised for late sepsis. No femoral component was revised for aseptic loosening. Six acetabular components had required revision, five for aseptic loosening. One additional acetabular component was revised for sepsis. Radiologically, all femoral components remained well fixed. One acetabular was judged loose by radiological criteria. The mean Harris Hip Score improved from 46 points (30 to 67) preoperatively to 89 points (78 to 100) at final follow-up. With revision for aseptic loosening as the endpoint, survival of the acetabular component was 95% (95% confidence interval (CI) 90 to 98) at 25 years. Femoral component survival was 100%. Conclusion. The most significant finding of this report was the low prevalence of aseptic loosening and revision of the femoral component at a mean follow-up of 22 years. A second important finding was the survival of over 90% of the hemispheric threaded ring acetabular components. While these shells remain controversial, in this series they performed well. Cite this article: Bone Jt Open 2021;2(1):33–39


The Bone & Joint Journal
Vol. 104-B, Issue 7 | Pages 833 - 843
1 Jul 2022
Kayani B Baawa-Ameyaw J Fontalis A Tahmassebi J Wardle N Middleton R Stephen A Hutchinson J Haddad FS

Aims. This study reports the ten-year wear rates, incidence of osteolysis, clinical outcomes, and complications of a multicentre randomized controlled trial comparing oxidized zirconium (OxZr) versus cobalt-chrome (CoCr) femoral heads with ultra-high molecular weight polyethylene (UHMWPE) and highly cross-linked polyethylene (XLPE) liners in total hip arthroplasty (THA). Methods. Patients undergoing primary THA were recruited from four institutions and prospectively allocated to the following treatment groups: Group A, CoCr femoral head with XLPE liner; Group B, OxZr femoral head with XLPE liner; and Group C, OxZr femoral head with UHMWPE liner. All study patients and assessors recording outcomes were blinded to the treatment groups. The outcomes of 262 study patients were analyzed at ten years’ follow-up. Results. Patients in Group C were associated with increased mean liner wear rates compared to patients in Group A (0.133 mm/yr (SD 0.21) vs 0.031 mm/yr (SD 0.07), respectively; p < 0.001) and Group B (0.133 mm/yr (SD 0.21) vs 0.022 mm/yr (SD 0.05), respectively; p < 0.001) at ten years’ follow-up. Patients in Group C were also associated with increased risk of osteolysis and aseptic loosening requiring revision surgery, compared with patients in Group A (7/133 vs 0/133, respectively; p = 0.007) and Group B (7/133 vs 0/135, respectively; p = 0.007). There was a non-statistically significant trend towards increased mean liner wear rates in Group A compared with Group B (0.031 mm/yr (SD 0.07) vs 0.022 mm/yr (SD 0.05), respectively; p = 0.128). All three groups were statistically comparable preoperatively and at ten years’ follow-up when measuring normalized Western Ontario and McMaster Universities Osteoarthritis Index (p = 0.410), 36-Item Short Form Health Survey (p = 0.465 mental, p = 0.713 physical), and pain scale scores (p = 0.451). Conclusion. The use of UHMWPE was associated with progressively increased annual liner wear rates after THA compared to XLPE. At ten years’ follow-up, the group receiving UHMWPE demonstrated an increased incidence of osteolysis and aseptic loosening requiring revision surgery compared to XLPE. Femoral heads composed of OxZr were associated with trend towards reduced wear rates compared to CoCr, but this did not reach statistical significance and did not translate to any differences in osteolysis, functional outcomes, or revision surgery between the two femoral head components. Cite this article: Bone Joint J 2022;104-B(7):833–843


Highly cross-linked polyethylene (HXLPE) has decreased wear and revision rates in total hip replacement (THR) at a long-term. However, the effect of HXLPE manufacturing characteristics on femoral head penetration has not been clearly defined yet. We report this single-institution study to investigate the clinical and radiological results of different HXLPE liners in THR. In this retrospective cohort analysis of our prospective database, we identified 904 THRs performed between 2000 and 2013. Seven different HXLPE liner types were assessed: remelted (3), annealed (2), sequentially annealed (1) and vitamin E-infused (1). The linear femoral head penetration rate was measured at six weeks, one year, and annually thereafter, using the Roman Software v1.70 package. Thirty hips were revised for the following reasons: aseptic loosening (11), dislocation (12), periprosthetic femoral fracture (6), and infection (1). No hip was revised for wear or osteolysis. 741 THRs were evaluated for a mean follow-up of 15 years (range, 10 to 20). The mean total penetration 15 years after THR was 0.17 mm in the sequentially annealed, and 0.16 mm in the vitamin E-infused groups, whereas it was 0.26 mm in the melted 95 kGy, 0.27 mm in the melted 5 Mrad and 0.25 mm in the melted 100 kGy groups (p=0.001). From one to 15 years after surgery, the mean wear was 0.206 mm in cups with an acetabular inclination greater than 50º and 0.105 mm in those placed between 35º and 50º (p<0.001). Although HXLPE characteristics can result in a different wear performance in patients undergoing THR at a mean follow-up of 15 years, the clinical results are excellent. The position of the acetabular component can influence on the femoral head penetration of modern HXLPEs. Nevertheless, these patients should continue to be monitored to detect future problems


The Bone & Joint Journal
Vol. 105-B, Issue 1 | Pages 29 - 34
1 Jan 2023
Fransen BL Bengoa FJ Neufeld ME Sheridan GA Garbuz DS Howard LC

Aims. Several short- and mid-term studies have shown minimal liner wear of highly cross-linked polyethylene (HXLPE) in total hip arthroplasty (THA), but the safety of using thinner HXLPE liners to maximize femoral head size remains uncertain. The objective of this study was to analyze clinical survival and radiological wear rates of patients with HXLPE liners, a 36 mm femoral head, and a small acetabular component with a minimum of ten years’ follow-up. Methods. We retrospectively identified 55 patients who underwent primary THA performed at a single centre, using HXLPE liners with 36 mm cobalt-chrome heads in acetabular components with an outer diameter of 52 mm or smaller. Patient demographic details, implant details, death, and all-cause revisions were recorded. Cox regression and Kaplan-Meier survival was used to determine all-cause and liner-specific revision. Of these 55 patients, 22 had a minimum radiological follow-up of seven years and were assessed radiologically for linear and volumetric wear. Results. Overall survival rate for all-cause revision was 94.5% (95% confidence interval (CI) 81.7% to 97.2%) at a mean follow-up of 12.8 years (10.9 to 18.7). Three patients were revised, none for liner wear, fracture, or dissociation. A total of 22 patients were included in the radiological analysis (mean follow-up 9.9 years (7.5 to 13.7)). Mean linear liner wear was 0.085 mm (95% CI -0.086 to 0.257) and the volumetric wear rate was 11.097 mm. 3. /year (95% CI -6.5 to 28.7). Conclusion. Using HXLPE liners with 36 mm heads in 52 mm acetabular components or smaller is safe, with excellent survival and low rates of linear and volumetric wear at medium-term follow-up. Patients did not require revision surgery for liner complications such as fracture, dissociation, or wear. Our results suggest that the advantages of using larger heads outweigh the potential risks of using thin HXLPE liners. Cite this article: Bone Joint J 2023;105-B(1):29–34


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_12 | Pages 17 - 17
23 Jun 2023
Schreurs BW van Veghel MH van der Koelen RE Hannink G Rijnen WH
Full Access

Although data on uncemented short stems are available, studies on cemented short-stemmed THAs are limited. These cemented short stems may have inferior long-term outcomes and higher femoral component fracture rates. Hence, we examined the long-term follow-up of cemented short Exeter stems used in primary THA. Within the Exeter stem range, 7 stems have a stem length of 125 mm or less. These stems are often used in small patients, in young patients with a narrow femoral canal or patients with anatomical abnormalities. Based on our local database, we included 394 consecutive cemented stems used in primary THA (n=333 patients) with a stem length ≤125 mm implanted in our tertiary referral center between 1993 and December 2021. We used the Dutch Arthroplasty Registry (LROI) to complete and cross-check the data. Kaplan-Meier survival analyses were performed to determine 20-year survival rates with stem revision for any reason, for septic loosening, for aseptic loosening and for femoral component fracture as endpoints. The proportion of male patients was 21% (n=83). Median age at surgery was 42 years (interquartile range: 30–55). The main indication for primary THA was childhood hip diseases (51%). The 20-year stem survival rate of the short stem was 85.4% (95% CI: 73.9–92.0) for revision for any reason and 96.2% (95%CI: 90.5–98.5) for revision for septic loosening. No stems were revised for aseptic femoral loosening. However, there were 4 stem fractures at 6.6, 11.6, 16.5 and 18.2 years of follow-up. The stem survival with femoral component fracture as endpoint was 92.7% (CI: 78.5–97.6) at 20 years. Cemented short Exeter stems in primary THA show acceptable survival rates at long-term follow-up. Although femoral component fracture is a rare complication of a cemented short Exeter stem, orthopaedic surgeons should be aware of its incidence and possible risk factors


The Bone & Joint Journal
Vol. 103-B, Issue 7 Supple B | Pages 66 - 72
1 Jul 2021
Hernandez NM Hinton ZW Wu CJ Lachiewicz PF Ryan SP Wellman SS

Aims. Modular dual mobility (MDM) acetabular components are often used with the aim of reducing the risk of dislocation in revision total hip arthroplasty (THA). There is, however, little information in the literature about its use in this context. The aim of this study, therefore, was to evaluate the outcomes in a cohort of patients in whom MDM components were used at revision THA, with a mean follow-up of more than five years. Methods. Using the database of a single academic centre, 126 revision THAs in 117 patients using a single design of an MDM acetabular component were retrospectively reviewed. A total of 94 revision THAs in 88 patients with a mean follow-up of 5.5 years were included in the study. Survivorship was analyzed with the endpoints of dislocation, reoperation for dislocation, acetabular revision for aseptic loosening, and acetabular revision for any reason. The secondary endpoints were surgical complications and the radiological outcome. Results. The overall rate of dislocation was 11%, with a six-year survival of 91%. Reoperation for dislocation was performed in seven patients (7%), with a six-year survival of 94%. The dislocations were early (at a mean of 33 days) in six patients, and late (at a mean of 4.3 years) in four patients. There were three intraprosthetic dissociations. An outer head diameter of ≥ 48 mm was associated with a lower risk of dislocation (p = 0.013). Lumbrosacral fusion was associated with increased dislocation (p = 0.004). Four revision THAs (4%) were further revised for aseptic acetabular loosening, and severe bone loss (Paprosky III) at the time of the initial revision was significantly associated with further revision for aseptic acetabular loosening (p = 0.008). Fourteen acetabular components (15%) were re-revised for infection, and a pre-revision diagnosis of reimplantation after periprosthetic joint infection (PJI) was associated with subsequent PJI (p < 0.001). Two THAs had visible metallic changes on the backside of the cobalt chromium liner. Conclusion. When using this MDM component in revision THA, at a mean follow-up of 5.5 years, there was a higher rate of dislocation (11%) than previously reported. The size of the outer bearing was related to the risk of dislocation. There was a low rate of aseptic acetabular loosening. Longer follow-up of this MDM component and evaluation of other designs are warranted. Cite this article: Bone Joint J 2021;103-B(7 Supple B):66–72


The Bone & Joint Journal
Vol. 106-B, Issue 2 | Pages 136 - 143
1 Feb 2024
van der Lelij TJN Marang-van de Mheen PJ Kaptein BL Koster LA Ljung P Nelissen RGHH Toksvig-Larsen S

Aims. The objective of this study was to compare the two-year migration and clinical outcomes of a new cementless hydroxyapatite (HA)-coated titanium acetabular shell with its previous version, which shared the same geometrical design but a different manufacturing process for applying the titanium surface. Methods. Overall, 87 patients undergoing total hip arthroplasty (THA) were randomized to either a Trident II HA or Trident HA shell, each cementless with clusterholes and HA-coating. All components were used in combination with a cemented Exeter V40 femoral stem. Implant migration was measured using radiostereometric analysis (RSA), with radiographs taken within two days of surgery (baseline), and at three, 12, and 24 months postoperatively. Proximal acetabular component migration was the primary outcome measure. Clinical scores and patient-reported outcome measures (PROMs) were collected at each follow-up. Results. Mean proximal migrations at three, 12, and 24 months were 0.08 mm (95% confidence interval (CI) 0.03 to 0.14), 0.11 mm (95% CI 0.06 to 0.16), and 0.14 mm (95% CI 0.09 to 0.20), respectively, in the Trident II HA group, versus 0.11 mm (95% CI 0.06 to 0.16), 0.12 mm (95% CI 0.07 to 0.17), and 0.14 mm (95% CI 0.09 to 0.19) in the Trident HA group (p = 0.875). No significant differences in translations or rotations between the two designs were found in any other direction. Clinical scores and PROMs were comparable between groups, except for an initially greater postoperative improvement in Hip disability and Osteoarthritis Outcome Symptoms score in the Trident HA group (p = 0.033). Conclusion. The Trident II clusterhole HA shell has comparable migration with its predecessor, the Trident hemispherical HA cluster shell, suggesting a similar risk of long-term aseptic loosening. Cite this article: Bone Joint J 2024;106-B(2):136–143


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_12 | Pages 67 - 67
23 Jun 2023
Yamamoto T Fujita J
Full Access

Injury of the lateral femoral cutaneous nerve (LFCN) is one of the known complications after periacetabular osteotomy (PAO) using anterior approach. We previously reported that the incidence of LFCN injury was 48% at 1 year after PAO. However, there was no study examining the sequential changes of LFCN injury status. In this study, we performed a prospective over 3-year follow-up study as to the incidence of LFCN injury as well as its clinical outcomes. This study included 40 consecutive hips in 40 patients (3 males and 37 females) who underwent PAO from May 2016 to July 2018. The mean age at surgery was 36.7 years (17 to 60). The mean observation period was 47.3 months (36 to 69). The incidence and severity of LFCN injury was evaluated, while clinical scores, including the Harris Hip Score (HHS), Short-Form 36 Health Survey (SF-36), and Japanese Orthopaedic Association Hip Disease Evaluation Questionnaire (JHEQ), were also investigated. At 3 years after PAO, LFCN injury was observed in 13 of 40 (33%) patients, in which 7 patients who had a symptom at 1 year have completely recovered. There was no significant difference in the HHS and SF-36 between patients with and without LFCN injury at 3 years. Regarding the JHEQ, a significant difference was recognized in the patient satisfaction and mental score between patients with and without LFCN injury, but there were no significant differences in the other clinical scores. The incidence of LFCN injury gradually decreased to 33% at 3 years after CPO. LFCN injury did not influence the clinician-reported outcome, while it had a negative impact on patient satisfaction and mental score based on the patient-reported outcome


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_4 | Pages 18 - 18
1 Apr 2022
Kayani B Baawa J Fontalis A Tahmassebi J Wardle N Middleton R Hutchinson J Haddad FS
Full Access

This study reports the ten-year polyethylene liner wear rates, incidence of osteolysis, clinical outcomes and complications of a three-arm, multicentre randomised controlled trial comparing Cobalt-Chrome (CoCr) and Oxidised Zirconium (OxZr) femoral heads with ultra-high molecular weight polyethylene (UHMWPE) versus highly cross-linked polyethylene (XLPE) liners in total hip arthroplasty (THA). Patients undergoing THA from four institutions were prospectively randomised into three groups. Group A received a CoCr femoral head and XLPE liner; Group B received an OxZr femoral head and XLPE liner; and Group C received an OxZr femoral head and UHMWPE liner. Blinded observers recorded predefined outcomes in 262 study patients at regular intervals for ten years following THA. At ten years follow-up, increased linear wear rates were recorded in group C compared to group A (0.133 ± 0.21 mm/yr vs 0.031 ± 0.07 mm/yr respectively, p<0.001) and group B (0.133 ± 0.21 mm/yr vs 0.022 ± 0.05 mm/yr respectively, p<0.001). Patients in group C were associated with increased risk of osteolysis and aseptic loosening requiring revision surgery compared with group A (7/133 vs 0/133 respectively, p=0.007) and group B (7/133 vs 0/135 respectively, p=0.007). There was a non-significant trend towards increased liner wear rates in group A compared to group B (0.031 ± 0.07 mm/yr vs 0.022 ± 0.05 mm/yr respectively, p=0.128). All three groups were statistically comparable preoperatively and at ten years follow-up when measuring normalised Western Ontario and McMaster Universities Osteoarthritis Index(p=0.410), short-form-36 (p = 0.465 mental, p = 0.713 physical), and pain scale scores (p=0.451). The use of UHMWPE was associated with progressively increased annual liner wear rates after THA. At ten years follow-up, this translated to UHMWPE leading to an increased incidence of osteolysis and aseptic loosening requiring revision THA, compared with XLPE. Femoral heads composed of OxZr were associated with a non-significant trend towards reduced wear rates compared to CoCr, but this did not translate to any differences in osteolysis, functional outcomes, or revision surgery between the two treatments groups


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_5 | Pages 13 - 13
1 Jul 2020
Stone M Smith L Kingsbury S Czoski-Murray C Judge A Pinedo-Villanueva R West R Wright J Smith C Arden N Conaghan P
Full Access

Follow-up of arthroplasty varies widely across the UK. The aim of this NIHR-funded study was to employ a mixed-methods approach to examine the requirements for arthroplasty follow-up and produce evidence-based and consensus-based recommendations. It has been supported by BHS, BASK, BOA, ODEP and NJR. Four interconnected work packages have recently been completed: (1) a systematic literature review; (2a) analysis of routinely collected National Health Service data from four national data sets to understand when and which patients present for revision surgery; (2b) prospective data regarding how patients currently present for revision surgery; (3) economic modelling to simulate long-term costs and quality-adjusted life years associated with different follow-up care models and (4) a Delphi-consensus process, involving all stakeholders, to develop a policy document to guide appropriate follow-up care after primary hip and knee arthroplasty. We will present the following Recommendations:. For ODEP10A∗ minimum implants, it is safe to disinvest in routine follow-up from 1 to 10 years post non-complex hip and knee replacement provided there is rapid access to orthopaedic review. For ODEP10A∗ minimum implants in complex cases, or non-ODEP10A∗ minimum implants, periodic follow-up post hip and knee replacement may be required from 1 to 10 years. At 10 years post hip and knee replacement, we recommend clinical, which may be virtual, and radiographic evaluation. After 10 years post hip and knee replacement, frequency of further follow-up should be based on the 10-year assessment; ongoing rapid access to orthopaedic review is still required. Overarching statements. These recommendations apply to post primary hip and knee replacement follow-up. The 10-year time point in these recommendations is based on a lack of robust evidence beyond ten years. The term complex cases refer to individual patient and surgical factors that may increase the risk for replacement failure


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_10 | Pages 36 - 36
1 Oct 2020
Hernandez NM Hinton ZW Wu CJ Lachiewicz PF Ryan SP Wellman SS
Full Access

Background. Modular dual mobility (MDM) acetabular components are often used to prevent dislocation in revision total hip arthroplasty (THA). As there is insufficient data on these components, the outcomes were evaluated in a cohort with a mean follow-up time of greater than five years. Methods. Using the database of a single academic center, 126 revision THAs (117 patients) with one MDM were retrospectively reviewed. There were 94 hips in 88 patients with a mean follow-up time of 5.5 years. Survivorship analysis was performed with the endpoints of dislocation, reoperation for dislocation, cup revision for aseptic loosening, and cup revision for any reason. The secondary endpoints were perioperative complications and radiographic review. Results. The overall rate of dislocation was 11%, with a 6-year survival of 91%. Reoperation for dislocation was performed in 7 patients (7%), with a 6-year survival of 94%. The dislocations were early (mean 33 days) in 6 patients, and late (mean 4.3 years) in 4 patients. There were three intraprosthetic dissociations. An outer head diameter of 48 mm or greater was associated with a lower risk of dislocation (p=0.013). Four hips (4%) were revised for aseptic cup loosening, and 14 (15%) cups were revised for infection. Two hips had visible metallic changes of the backside of the cobalt chromium liner. Conclusion. Using this MDM component in revision THA, at mean follow-up time of 5.5 years, there was a higher rate of dislocation (11%) than previously reported. Outer bearing size was related to the risk of dislocation. There was a low rate of aseptic cup loosening. Longer follow-up of this MDM component and evaluation of other designs is warranted