With greater numbers of younger patients undergoing
total hip replacement (THR), the effect of patient age on the diameter
of the femoral canal may become more relevant. This study aimed
to investigate the relationship between the diameter of the diaphysis
of the femoral canal with increasing age in a large number of patients
who underwent THR. A total of 1685 patients scheduled for THR had
their femoral dimensions recorded from calibrated radiographs. There
were 736 males and 949 females with mean ages of 67.1 years (34
to 92) and 70.2 years (29 to 92), respectively. The mean diameter
of the femoral canal was 13.3 mm (8.0 to 23.0) for males and 12.7
mm (6.0 to 26.0) for females. There was a poor correlation between
age and the diameter of the canal in males (r = 0.071, p = 0.05)
but a stronger correlation in females (r = 0.31, p <
0.001). The diameter of the
Absorbable cement restrictors have been in use over the last few years. They have been shown to be as effective as the standard non-absorbable cement restrictors in achieving cement pressurisation and stopping distal cement migration in in vitro studies. The aim of this study is to compare in vivo, the effectiveness of absorbable with non-absorbable cement restrictors. One hundred and thirty-six consecutive patients who had total hip replacement performed using charnley cemented femoral prosthesis were selected and randomly divided in to two groups pre operatively. One group received Hardinge TM non-absorbable cement restrictor and the second group received Biostop TM absorbable cement restrictor. Type of the prosthesis, the surgical approach, the time from start of mixing of the cement to insertion of the cement (measure of viscosity of the cement), the cementing technique and the distance at which the cement restrictor was inserted were noted intraoperatively, the canal diameter was measured from the preoperative AP radiograph of the hip. The distance at which the cement restrictor was inserted was measured on the AP radiograph of the hip taken twenty-four hours postoperatively. All the above factors were statistically assessed as to their effect in the distal migration on cement restrictor using multiple regression analysis. There was no statistical difference between the two types of cement restrictors (P= 0.44). Surgeon, Surgical approach,
Background. Cement restrictors are used for maintaining good filling and pressurization of bone cement during hip and knee arthroplasties. The limitations of certain cement restrictors include the inability to accommodate for large medullary canals particularly in revision procedures. We describe a technique using SurgicelTM (Johnson & Johnson) and SPONGOSTAN™ (Johnson & Johnson) (Fig 1) to form a cement restrictor that can accommodate for large canal diameters and provide excellent pressurisation. Technique. The technique involves the application of SPONGOSTAN™ (Johnson & Johnson) foam onto a SurgicelTM (Johnson & Johnson) mesh which is then rolled onto the SPONGOSTAN™ foam forming a uniform cylindrical structure Figs 2,3. The diameter of the restrictor can be adjusted according to the desired
Introduction: Following the introduction of a hip hemiarthroplasty monobloc a number of unusual problems occurred in our unit. These included the need for narrow stem prostheses, on table revision for excessive anteversion and intra-operative fracture, revision for irreducible dislocation and excision arthroplasty. It was noted that the trial component fitted easily whereas there were problems with insertion of the actual prostheses. Methods: To investigate the issue of differences in the trial component versus the actual prosthesis the following methods were employed. Digital micrometer measurements were taken from the trial and real components. Differences in the antero-posterior and medial-lateral dimensions of the components were analysed. Cross-sectional area analysis was also performed. The effect of
Introduction: The anatomy of the proximal femur is an important factor in the design of uncemented femoral prostheses for which the quality of fixation and the associated bony remodelling depend on the primary stability and optimal transmission of forces to the proximal femur. This study looks at the variation in the diameter of the proximal femur with age and sex in a homogeneous population. Materials and Methods: We studied standardised pre-operative antero-posterior radiographs of the proximal femur of 2,777 patients who have undergone total hip arthroplasty using a custom implant over a 10 year period. The radiographs were corrected for magnification and a measurement made of the endosteal diameter at the narrowest point of the proximal femur. These measurements were used in the design and manufacture of the custom femoral implant. Results: Of 2777 patients, 1588 were female and 1189 male. The mean age for females was 69.9 years (Range 30–92) and for males 67.2 years (Range 34–92). The mean proximal
Introduction: Intramedullary nailing is an acceptable method of treatment for femoral shaft fractures today. We present our experience from the use-of four different nails. Patients and Methods: Thirty fractures of the femoral shaft were treated by intramedullary nailing from Jan98–DecOl in our department. The patients’ age ranged from 19 to 87 (avg 36 ys). Twelve fractures were in poly-trauma patients. In 6 patients, due to an intense comminution, an external fixation was initially applied and a delayed intramedullary nailing was performed. Four different types of nails were used 8 Grosse &
.Kempf, 1 Orthofix ,2 ZMS (Zimmer), and 19 Marchetti Vicenzi. Results: All patients were followed up until complete union of the fracture. A 1.5 cm shortening was found in one patient and two patients presented a valgus 7° at the fracture site. One pseudarthosis with broken implant (Marchetti) was seen and treated with a new nail of the same type. The Orthofix nail was used only once due to its lack of anatomic curvature. The mean surgical time of the GK and ZMS nails was 30 minutes more than that of Marchetti nails, due to the distal locking screws required. Conclusions: In our own experience, GK and ZMS nails provide a larger contact area in the endosteum as well as the best conditions for biomechanically sound distribution of loading. The placement of distal locking screws constitutes a major problem, as it requires extended surgical time and increased exposure to irradiation. The important advantage of the Marchetti nail is that no distal screws are required, so the operation and fluoroscopy time are much shorter. The main disadvantages of the Marchetti nail are the absence of quidewire during nail insertion, the minimal 13mm
When performing revision total hip arthroplasty using diaphyseal-engaging titanium tapered stems (TTS), the recommended 3 to 4 cm of stem-cortical diaphyseal contact may not be available. In challenging cases such as these with only 2 cm of contact, can sufficient axial stability be achieved and what is the benefit of a prophylactic cable? This study sought to determine, first, whether a prophylactic cable allows for sufficient axial stability when the contact length is 2 cm, and second, if differing TTS taper angles (2° vs 3.5°) impact these results. A biomechanical matched-pair cadaveric study was designed using six matched pairs of human fresh cadaveric femora prepared so that 2 cm of diaphyseal bone engaged with 2° (right femora) or 3.5° (left femora) TTS. Before impaction, three matched pairs received a single 100 lb-tensioned prophylactic beaded cable; the remaining three matched pairs received no cable adjuncts. Specimens underwent stepwise axial loading to 2600 N or until failure, defined as stem subsidence > 5 mm.Aims
Methods
Femoral revision component subsidence has been identified as predicting early failure in revision hip surgery. This comparative cohort study assessed the potential risk factors of subsidence in two commonly used femoral implant designs. A comparative cohort study was undertaken, analyzing a consecutive series of patients following revision total hip arthroplasties using either a tapered-modular (TM) fluted titanium or a porous-coated cylindrical modular (PCM) titanium femoral component, between April 2006 and May 2018. Clinical and radiological assessment was compared for both treatment cohorts. Risk factors for subsidence were assessed and compared.Aims
Methods
The purpose of this study was to measure the
radiological parameters of femoral component alignment of the Oxford
Phase 3 unicompartmental knee replacement (UKR), and evaluate their
effect on clinical outcome. Multiple regression analysis was used
to examine the relative contributions of the radiological assessment
of femoral component alignment in 189 consecutive UKRs performed
by a single surgeon. The American Knee Society scores were compared
between groups, defined as being within or outside recommended tolerances
of the position of the femoral component. For the flexion/extension
position 21 UKRs (11.1%) lay outside the recommended limits, and for
posterior overhang of the femoral component nine (4.8%) lay outside
the range. The pre-operative hip/knee/ankle (HKA) angle, narrowest
canal distance from the distal femoral entry point of the alignment
jig and coronal entry-point position had significant effects on
the flexion/extension position. Pre-operative HKA angle had a significant
influence on posterior overhang of the femoral component. However,
there was no significant difference in American Knee Society scores
relative to the position of the femoral component.
The use of short stems has become more popular
with the increased interest in less invasive approaches for total hip
arthroplasty. The curved broaches and stem can be inserted along
a curved track to avoid the abductor attachments. Short stems have
the potential of being more bone conserving by allowing for higher
neck retention, maintenance of the medial greater trochanter, and
preferential stress transfer to the proximal femur. An initial experience with 500 new short stems (Fitmore, Zimmer
Orthopedics) stems used for total hip arthroplasty is reported.
No stems have been revised for aseptic loosening.
We report the results of 79 patients (81 hips)
who underwent impaction grafting at revision hip replacement using the
Exeter femoral stem. Their mean age was 64 years (31 to 83). According
to the Endoklinik classification, 20 hips had a type 2 bone defect,
40 had type 3, and 21 had type 4. The mean follow-up for unrevised
stems was 10.4 years (5 to 17). There were 12 re-operations due to intra- and post-operative
fractures, infection (one hip) and aseptic loosening (one hip).
All re-operations affected type 3 (6 hips) and 4 (6 hips) bone defects.
The survival rate for re-operation for any cause was 100% for type
2, 81.2% (95% confidence interval (CI) 67.1 to 95.3) for type 3,
and 70.8% (95% CI 51.1 to 90.5) for type 4 defects at 14 years.
The survival rate with further revision for aseptic loosening as
the end point was 98.6% (95% CI 95.8 to 100). The final clinical
score was higher for patients with type 2 bone defects than type
4 regarding pain, function and range of movement. Limp was most
frequent in the type 4 group (p <
0.001). The mean subsidence
of the stem was 2.3 mm ( The impacted bone grafting technique has good clinical results
in femoral revision. However, major bone defects affect clinical
outcome and also result in more operative complications.