Aims. To evaluate whether an ultra-low-dose CT protocol can diagnose
selected
Aims. This study aimed to investigate the clinical characteristics and outcomes associated with culture-negative
Aims. Complex fractures of the femur and tibia with associated severe soft tissue injury are often devastating for the individual. The aim of this study was to describe the two-year patient-reported outcomes of patients in a civilian population who sustained a complex fracture of the femur or tibia with a Mangled
Introduction. This study evaluates the need for
Purpose. To review the natural history of posteromedial bowing of the tibia and the outcome of
Component malalignment has long been implicated in poor implant survival in Total Knee Arthroplasty (TKA). Malalignment can occur in orientation of bony cuts, and in component cementation/implantation. Several systems exist to aid bony cut alignment (navigation, shape matching), but final implantation technique is common to all TKA. Correction of errors in bony cut alignment at cementation/implantation by surgeons has been described. Changes in alignment at this stage are likely to result in asymmetrical cement penetration, which is implicated in early failure. This study reviewed a consecutive series of 150 primary cemented TKAs using an imageless navigation system (aiming for neutral overall
The aim of this study was to determine medium term functional outcomes in military casualties undergoing
Introduction. Distraction histogenesis is utilised for cosmetic reasons in patients with constitutional short stature, achondroplasias, or height dysphoria. One of the considerations of patients and surgeons alike, is the preservation of aesthetically acceptable body proportions after the lengthening i.e which segment of the lower limb to lengthen and by how much, in order to preserve the patient's proportions within -or as close as possible to- the normal range of human body proportions. Sound anthropometric data on the normal range of the human body proportions is currently lacking. The aim of this study is to calculate the normal range of the ratio between the lengths of the lower limb, upper limb, femur, tibia, stature and trunk. Methods. Data form standardized measurements of the lengths of the tibia, femur, arm, stature, lower limb, upper limb was obtained from a sample population of 6068 healthy men and women servicing in the US Army. The mean, median, range and standard deviation were calculated for the following ratios of lengths: whole lower limb/leg, Stature/leg, Whole lower limb/thigh, Stature/thigh, Siting height/whole lower limb, Stature/Whole lower limb, Arm Span/Stature, Whole upper limb/Whole lower limb. Results. The ratios show normal distribution. Results are presented separately for men and women for the total sample population and for subgroups based on ethnic origin (White, Black, Hispanic and Asian). Discussion. This study is one of the first to provide specific anthropometric data from a large sample population relevant to the evidence-based preoperative planning and patient counselling before cosmetic
Introduction. The Precice nail is the latest intramedullary lengthening nail with excellent early outcomes. Implant complications have led to modification of the nail design. The aim of this study was to perform a retrieval study of Precice nails following lower limb lengthening. To assess macroscopic and microscopic changes to the implants and assess differences following design modification, with identification of potential surgical, implant and patient risk factors. Method. 15 nails were retrieved from 13 patients following lower limb lengthening. Macroscopic and microscopic surface damage to the nails were identified. Further analysis included radiology and micro-CT prior to sectioning. The internal mechanism was then analysed with Scanning Electron Microscopy and Energy Dispersive X-ray Spectroscopy to identify corrosion. Results. 7 male and 3 females underwent 12 femoral lengthenings, 9 antegrade and 3 retrograde. 3 females underwent tibial lengthening. All patients obtained the desired length with no implant failure and full regenerate consolidation. Surface degradation was noted on the telescopic part of every nail design, less on the latest implants. Microscopic analysis confirmed fretting and pitting corrosion. Following sectioning black debris was noted in all implants. The early designs were found to have fractured actuator pins and the pin and bearings had evidence of corrosive debris. The latest designs had evidence of biological deposits suggestive of fluid ingress within the nail. Conclusion. This study suggests fluid ingress occurs with every generation of Precice nail despite modifications. The presence of biological fluid could be an early warning sign of potential corrosion. This in theory could lead to actuator pin fracture and implant failure. The clinical relevance is the potential re-use of a “dormant” nail in patients requiring secondary
Care of complex and open fractures may provide better results if undertaken in larger units, typically Major Trauma Centres (MTCs) or Orthoplastic units. Some ‘complex injuries’ may still be admitted to units lacking specialist services potentially delaying definitive treatment. The aim of this study was to analyse the referral pattern for acute inpatient transfer in an adult
Aim. Simultaneous application of Ilizarov frames and free muscle flaps to treat osteomyelitis or infected non-unions is currently not standard practice in the UK, in part related to logistical issues, surgical duration and challenging access for microvascular anastomosis. We present the outcomes for 56 such patients. Methods. Retrospective single centre consecutive series between 2005–2017. We recorded comorbidities, Cierny-Mader and Weber-Cech classification, the Ilizarov method used, flap and anastomosis used, follow-up duration, time to union and complications. Results. 56 patients (55 tibiae and 1 forearm) were included (mean age 48 years). Thirty-four cases had osteomyelitis (20/34 Cierny-Mader Stage IV) and 22 had an infected non-union (14/22 Weber-Cech Type E or F). Forty-six patients had a segmental defect after resection. Monofocal compression was used in 14, monofocal distraction in 15, bifocal compression/distraction in 8, bone transport in 9 and a protective frame in 10. 8/56 had an ankle fusion, 7/56 had an angular deformity corrected at the same time and 32 also had local antibiotic carrier inserted. Forty-six gracilis, 9 latissimus dorsi and 1 rectus abdominus flaps were used. Six cases required urgent flap re-exploration (5 anastomotic revisions and 1 haematoma washout) with 4/6 successfully salvaged. Two cases suffered total flap failure (3.6%). Both had successful revision free muscle flaps with the frame in situ at 10 and 16 days respectively. There were no partial flap failures and no failures in bone transport frames. Mean follow-up was 22 months (4–89). Excluding three cases that still have a frame on, 42/43 (97.7%) achieved bony union. Recurrence of infection occurred in 8.9%. All were infection free at final follow-up after further surgery. Conclusions. With the right expertise, simultaneous Ilizarov frame and free muscle flap is safe and effective in treating complex
Objectives. The biomembrane (induced membrane) formed around polymethylmethacrylate (PMMA) spacers has value in clinical applications for bone defect reconstruction. Few studies have evaluated its cellular, molecular or stem cell features. Our objective was to characterise induced membrane morphology, molecular features and osteogenic stem cell characteristics. Methods. Following Institutional Review Board approval, biomembrane specimens were obtained from 12 patient surgeries for management of segmental bony defects (mean patient age 40.7 years, standard deviation 14.4). Biomembranes from nine tibias and three femurs were processed for morphologic, molecular or stem cell analyses. Gene expression was determined using the Affymetrix GeneChip Operating Software (GCOS). Molecular analyses compared biomembrane gene expression patterns with a mineralising osteoblast culture, and gene expression in specimens with longer spacer duration (> 12 weeks) with specimens with shorter durations. Statistical analyses used the unpaired student t-test (two tailed; p < 0.05 was considered significant). Results. Average PMMA spacer in vivo time was 11.9 weeks (six to 18). Trabecular bone was present in 33.3% of the biomembrane specimens; bone presence did not correlate with spacer duration. Biomembrane morphology showed high vascularity and collagen content and positive staining for the key bone forming regulators, bone morphogenetic protein 2 (BMP2) and runt-related transcription factor 2 (RUNX2). Positive differentiation of cultured biomembrane cells for osteogenesis was found in cells from patients with PMMA present for six to 17 weeks. Stem cell differentiation showed greater variability in pluripotency for osteogenic potential (70.0%) compared with chondrogenic or adipogenic potentials (100% and 90.0%, respectively). Significant upregulation of BMP2 and 6, numerous collagens, and bone gla protein was present in biomembrane compared with the cultured cell line. Biomembranes with longer resident PMMA spacer duration (vs those with shorter residence) showed significant upregulation of bone-related, stem cell, and vascular-related genes. Conclusion. The biomembrane technique is gaining favour in the management of complicated bone defects. Novel data on biological mechanisms provide improved understanding of the biomembrane’s osteogenic potential and molecular properties. Cite this article: Dr H. E. Gruber. Osteogenic, stem cell and molecular characterisation of the human induced membrane from
Aim To develop a militarily relevant complex
A 7-day randomised controlled pre-clinical trial utilising an existing
Introduction. Since 2001 we use the flexible intramedullary nailing (FIN) in bone lengthening in children. This study estimates results of EF+FIN association considering the duration of external fixation and complications. Materials and Methods. Since 2001 we performed 294 bone lengthenings (338 segments of UL and LL) in 250 children 3 to 16 years old (11.01±0.23 in average). The length discrepancy was congenital in 163 cases, the sequelae of trauma or osteomyelitis were observed in 87 patients. In group I (195 cases) the Ilizarov fixator alone was applied, in group II the Ilizarov fixator (91 cases) or TSF® (8cases) were combined with FIN. The healing index was compared between the groups of the same etiology with similar type of distraction osteosynthesis. The date of consolidation corresponded to the day of removal of the external fixator, while intramedullary nails remained in place thus protecting the bone. Healing index was calculated by relating the duration of wearing of the external fixator (in days) and the amount of lengthening (in cm). Results. Reduction of the healing index is noted in each compared category. Thus, in congenital shortening in monofocal distraction osteosynthesis of the femur the healing index decreased from 29.8 (group I) to 20.4 days per cm, in bifocal tibial lengthening from 22.7 (group I) to 16.3d/cm (group II), in humeral lengthening – from 30.2 to 21.3 d/cm. In fact, it appears that the association of the external fixator of the Ilizarov type or TSF® with FIN allows to reduce the healing index significantly: in 12 of 16 compared categories the reduction of the index was from 20% to 40% or from 4.0 to 19.1 days per cm. In group I four cases of deep infection of soft tissues, 2 osteomyelitis, 21 fractures or deformities after frame removal were manifested. In group II – onlyone case of deformation after frame removal, absence of severe infectious complications, 8 cases of migration of the intramedullary wires. Discussion. FIN creates an elastic and resistant system during the lengthening. We even suggest that it stimulates the formation considering an apparent decrease of the healing index. On the other hand, the elasticity of nails prevents secondary fractures or deformations after frame removal. Conclusion. Combination of the circular EF and FIN in
The use of external fixation in the management of long bone fractures has long been recognised. The aim of this study was to compare 3 differing constructs of Hoffman-2 and Hoffman-3 External Fixator systems to assess which potentially withstood the greatest load. Three different constructs (2, 3 and 4-bar) of Hoffman 2 and 3 External Fixation systems were tested. A UHMWPE tube was utilised as a bone substitute to construct a biomechanically reproducible model which could be tested on an MTS testing jig. Each construct was loaded to 3, 5, 8, 12 and 15mm of displacement at the fracture gap. Each construct was cyclically loaded 200 times for each test and repeated 5 times. The results demonstrate that the Hoffman-3 configurations withstood a load of at least twice that of the Hoffman 2 configurations across all displacements. Using a 2-way ANOVA test at all displacements the 2-bar configuration withstood greater load than the 3 bar (P<0.0001). With Hoffman 2 the 2-bar configuration withstood a greater load than the 4 bar diamond configuration. These results demonstrate that Hoffman-3 External Fixation Device has a greater axial loading capacity than its Hoffman-2 predecessor.
Leg length discrepancy (LLD) can adversely affect functional outcome and patient satisfaction after total hip arthroplasty. We describe a novel intraoperative technique for femoral component insertion. We aimed to determine if this technique resulted in the desired femoral placement, as templated, and if this was associated with a reduced LLD. A series of fifty consecutive primary total hip replacements were studied. Preoperative digital templating was performed on standardised PA radiographs of the hips by the senior surgeon. The preoperative LLD was calculated and the distance from the superior tip of the greater trochanter to the predicted shoulder of the stem was calculated (GT-S). Intraoperatively, this length was marked on the rasp handle and the stem inserted to the predetermined level by the surgeon. This level corresponded to the tip of the greater trochanter and formed a continuous line to the mark on the rasp handle. Three independent blinded observers measured the GT-S on the postoperative radiographs. We assessed the relationship between the senior author's GT-S (preoperative) and the observers' GT-S (postoperative) using a Person correlation. The observers also measured the preoperative and postoperative LLD, and the inter-observer variability was calculated as the intra-class correlation coefficient. There was a strong correlation of preoperative and postoperative GT-S (R=0.87), suggesting that the stem was inserted as planned. The mean preoperative and postoperative LLD were −4.3 mm (−21.4–4) and −0.9 mm (−9.8–8.6), respectively (p<0.001). This technique consistently minimised LLD in this series. This technique is quick, non-invasive and does not require supplementary equipment.
The aim of this study was to establish medium term outcomes in military casualties following severe open tibia fractures. Cases from a previously published series were contacted and assessed with the SF-36 outcome tool. Their results were then compared to a similar study of military trans-tibial amputees. Of the original data set of 49 patients, 30 patients were followed up and completed an SF-36 (61%) with a median follow-up of 4 years (49 months, IQR 397–63). Ten of the 30 required revision surgery, 3 of which involved conversion from initial fixation to a circular frame. Twenty-two of the 30 patients recovered sufficiently to complete a military basic fitness test. The median physical component of SF-36 in the tibia fracture group was 46 (IQR 35–54) which was similar to the trans-tibial amputation cohort (p=0.3057, Mann-Whitney). Similarly there was no difference in mental component scores (p=0.1595, Mann-Whitney). There was no significant difference in the proportion of patients in the amputation or fracture group reporting pain (p= 0.1157, Fisher's exact test) or with respect to SF-36 physical pain scores (p=0.5258, Mann-Whitney). We present the patient reported outcomes following combat open tibia fracture and show that they are similar to those achieved after trans-tibial amputation.
We present the results of 13 patients who suffered severe injuries to the lower leg. Five sustained a traumatic amputation and eight a Gustilo-Anderson type IIIC open fracture. All were treated with debridement, acute shortening and stabilisation of the fracture and vascular reconstruction. Further treatment involved restoration of tibial length by callus distraction through the distal or proximal metaphysis, which was commenced soon after the soft tissues had healed (n = 8) or delayed until union of the fracture (n = 5). All patients were male with a mean age of 28.4 years (17 to 44), and had sustained injury to the leg only. Chen grade II functional status was achieved in all patients. Although the number of patients treated with each strategy was limited, there was no obvious disadvantage in the early lengthening programme, which was completed more quickly.