In recent years there has been growing interest in enhanced recovery regimes in lower limb arthroplasty due to potential clinical benefits of early mobilisation along with cost-savings. Following adoption of this regime in a district general hospital, it was observed that traditional
Abstract. Objective. In this systematic review we aim to analyse the economical impact of using Negative Pressure Wound Therapy (NPWT) in primary total knee arthroplasty (TKA). Methods. Four medical electronic databases were searched. Eligible studies included those investigating the costs of NPWT in primary TKA. Exclusion criteria included studies investigating cost of NPWT not related to primary TKA. We also excluded studies with poor scientific methodology. We retrieved and analysed data on
Abstract. Objective. In this systematic review we aim to compare wound complication rates from Negative Pressure Wound Therapy (NPWT) to dry sterile surgical
Between 2016–2019, 4 patients developed hip infections post-hemiarthroplasty. However, between 2020–2021 (Covid-19 pandemic period), 6 patients developed hip infections following hip hemiarthroplasty. The purpose of the investigation is to establish the root causes and key learning from the incident and use the information contained within this report to reduce the likelihood of a similar incident in the future. 65 patients presented with a neck of femur fracture during Covid-19 pandemic period between 2020–2021, 26 had hip hemiarthroplasty of which 6 developed hip infections. Medical records, anaesthetic charts and post-hip infections guidelines from RCS and NICE were utilised. Proteus, Enterococci and Strep. epidermis were identified as the main organisms present causing the hip infection. The average number of ward moves was 4 with 90% of patients developing COVID-19 during their hospital stay. The chance of post-operative wound infection were multifactorial. Having had 5 of 6 patients growing enterococci may suggest contamination of wound either due to potential suboptimal hygiene measures, inadequate wound management /
The management of comminuted metaphyseal fractures is a technical challenge and satisfactory outcomes of such fixations often remain elusive. The small articular fragments and bone loss often make it difficult for standard fixation implants for proper fixation. We developed a novel technique to achieve anatomical reduction in multiple cases of comminuted metaphyseal fractures at different sites by employing the cantilever mechanism with the help of multiple thin Kirschner wires augmented by standard fixation implants. We performed a retrospective study of 10 patients with different metaphyseal fractures complicated by comminution and loss of bone stock. All patients were treated with the help of cantilever mechanism using multiple Kirschner wires augmented by compression plates. All the patients were operated by the same surgeon between November 2020 to March 2021 and followed up till March 2023. Surgical outcomes were evaluated according to the clinical and radiological criteria. A total of 10 patients were included in the study. Since we only included patients with highly unstable and comminuted fractures which were difficult to fix with traditional methods, the number of patients in the study were less. All 10 patients showed satisfactory clinical and radiological union at the end of the study with good range of motion. One of the patient in the study had post-operative wound complication which was managed conservatively with regular
To describe clinical situations for use of modified VAC in POC based on: diagnosis, comorbidities, BMI, wound size in cm, days following trauma when VAC was first applied, total duration of uninterrupted use, frequency of change, settings, bacterial growth, outcomes. To report the outcomes of mVAC use in POC within 6 months to help improve and standardize its application in the institution. This study involves data gathering from inpatients handled by orthopedic surgeons in training and subspecialty rotations in POC. The data collected are highly dependent on the doctors-in-charge's complete charting, thorough reporting and accurate documentation.
Modified Vacuum Assisted Closure (mVAC) is used frequently in this study and is defined as a form of revised, adapted and reformed use of VAC based on available materials in the involved institution. The materials that are included are, but not limited to the following: sterile Uratex™ blue foam, nasogastric or suction tubing, phlegm suction machine, Bactigras™ and Opsite™ or Ioban™. A total of 58 patients were included in the study. The average age of the population was 35 and are predominantly male. The most common mechanism of injury was motorcycle accident and 37 of the patients were diagnosed with an open fracture of the lower extremity with open tibia fractures (22) being the most common. Average wound area measured was 24.12 cm. 3. All patients yield a bacteria growth with e. coli being the most frequent. Average during of uninterrupted use was 39 days. Of the 58 included in the study, 8 patients underwent STSG, 2 had a flap coverage surgery, 4 patients eventually underwent amputation and 33 with complete resolution of soft tissue defect after conversion to biologic
Standard fixation for intra-articular distal humerus fracture is open reduction and internal fixation (ORIF). However, high energy fractures of the distal humerus are often accompanied with soft tissue injuries and or vascular injuries which limits the use of internal fixation. In our report, we describe a highly complex distal humerus fracture that showed promising healing via a ring external fixator. A 26-year-old man sustained a Gustillo Anderson Grade IIIB intra-articular distal humerus fracture of the non-dominant limb with bone loss at the lateral column. The injury was managed with aggressive wound debridement and cross elbow stabilization via a hinged ring external fixator. Post operative wound managed with foam
Abstract. Objective. Open fracture management in the United Kingdom and several other countries is guided by the British Orthopaedic Association's Standards for Trauma Number 4 (BOAST-4). This is updated periodically and is based on the best available evidence at the time. The aim of this study is to evaluate the evidence base forming this guidance and to highlight new developments since the last version in 2017. Methods. Searches have been performed using the PubMed, Embase and Medline databases for time periods a) before December 31, 2017 and from 01/01/2018–01/02/2021. Results have been summarised and discussed. Results. Several contentious issues remain within the 2017 guideline. Antibiotic guidance, the use of antibiotic impregnated PMMA beads and intramedullary devices, irrigation in the emergency department, time to theatre and the use of negative pressure
We compared the postoperative wound discharge rates and 3 months clinical results of three types of wound closure and
Invasive intraneural electrodes implanted in peripheral nerves are neural prosthetic devices that are exploied to control advanced neural-interfaced prostheses in human amputees. One of the main issues to be faced in chronic implants is represented by the gradual loss of functionality of such intraneural interfaces due to an electrical impedance increase caused by the progressive formation of a fibrotic capsule around the electrodes, which is originally due to a nonspecific inflammatory response called foreign body reaction (FBR). In this in vitro work, we tested the biocompatibility and ultra-low fouling features of the synthetic coating - poly(ethylene glycol) (PEG) - compared to the organic polymer - zwitterionic sulfated poly(sulfobetaine methacrylate) (SBMA) hydrogel - to prevent or reduce the first steps of the FBR: plasma protein adsorption and cell adhesion to the interface. Synthesis and characterization of the SBMA hydrogel was done. Preliminary biocompatibility analysis of the zwitterionic hydrogel, using hydrogel-conditioned medium, showed no cytotoxicity at all vs. control. We seeded GFP-labelled human myofibroblasts on PEG- and SBMA hydrogel-coated polyimide surfaces and evaluated their adhesion and cell viability at different time-points. Because of the high hydration, low stiffness reflecting the one of neural tissue, and ultra-low fouling characteristics of the SBMA hydrogel, this polymer showed lower myofibroblast adhesion and different cell morphology compared to adhesion controls, thereby representing a better coating than PEG for potentially mitigating the FBR. We conclude that soft SBMA hydrogels could outperform PEG coatings in vitro as more suitable
High-intensity narrow-spectrum (HINS) light is
a novel violet-blue light inactivation technology which kills bacteria through
a photodynamic process, and has been shown to have bactericidal
activity against a wide range of species. Specimens from patients
with infected hip and knee arthroplasties were collected over a
one-year period (1 May 2009 to 30 April 2010). A range of these
microbial isolates were tested for sensitivity to HINS-light. During
testing, suspensions of the pathogens were exposed to increasing
doses of HINS-light (of 123mW/cm. 2. irradiance). Non-light exposed
control samples were also used. The samples were then plated onto
agar plates and incubated at 37°C for 24 hours before enumeration.
Complete inactivation (greater than 4-log. 10. reduction)
was achieved for all of the isolates. The typical inactivation curve
showed a slow initial reaction followed by a rapid period of inactivation.
The doses of HINS-light required ranged between 118 and 2214 J/cm. 2.
Gram-positive bacteria were generally found to be more susceptible
than Gram-negative. As HINS-light uses visible wavelengths, it can be safely used
in the presence of patients and staff. This unique feature could
lead to its possible use in the prevention of infection during surgery
and post-operative
Background. The incidence of bleeding following primary TKR has increased with the use of chemical thromboprophylaxis. Our aim was to compare Clexane, Apixaban and Rivaroxaban in terms of frequency and volume of bleeding episodes, need for blood transfusion, return to theatre and incidence of VTE events. Methods. Between February and May 2014, a consecutive series of 132 primary TKRs were studied prospectively. The wound
Carpal tunnel decompression is one of the most commonly performed orthopaedic operations. Last year 160 patients attended our department for surgery. There have been reports in the literature of good results and improved patient satisfaction for wound closure with Vicryl Rapide following Dupuytren's surgery. We looked at 200 consecutive patients who underwent carpal tunnel decompression. Wounds were closed using either non-absorbable monofilament sutures (first 97 patients) or interrupted Vicryl Rapide (next 103 patients). We compared the incidence of wound problems in the early post operative period, scar sensitivity and the number of patients requiring a further outpatient appointment because of ongoing problems associated with these issues. There was a higher incidence of early wound problems (p=0.0359) in patients whose wounds were closed with nylon. There was no difference in the rates of scar tenderness (p=1) or in the number of patients requiring further clinic appointments (p=0.356). There are also potential cost savings in using absorbable sutures as they require fewer sundry items at the
Infection rates following arthroplasty surgery are between 1–4%, with higher rates in revision surgery. The associated costs of treating infected arthroplasty cases are considerable, with significantly worse functional outcomes reported. New methods of infection prevention are required. HINS-light is a novel blue light inactivation technology which kills bacteria through a photodynamic process. The aim of this study was to investigate the efficacy of HINS-light for the inactivation of bacteria isolated from infected arthoplasty cases. Specimens from hip and knee arthroplasty infections are routinely collected to identify causative organisms. This study tested a range of these isolates for sensitivity to HINS-light. During testing, bacterial suspensions were exposed to increasing doses of HINS-light of (123mW/cm. 2. irradiance). Non-light exposed control samples were also set-up. Bacterial samples were then plated onto agar plates and incubated at 37°C for 24 hours before enumeration. Complete inactivation was achieved for all Gram positive and negative microorganisms. More than a 4-log reduction in Staphylococcus epidermidis and Staphylococcus aureus populations were achieved after exposure to HINS-light for doses of 48 and 55 J/cm. 2. , respectively. Current investigations using Escherichia coli and Klebsiella pneumoniae show that gram-negative organisms are also susceptible, though higher doses are required. This study has demonstrated that HINS-light successfully inactivated all clinical isolates from infected arthroplasty cases. As HINS-light utilises visible-light wavelengths it can be safely used in the presence of patients and staff. This unique feature could lead to possible applications such as use as an infection prevention tool during surgery and post-operative
Infection rates following arthroplasty surgery are between 1–4%, with higher rates in revision surgery. The associated costs of treating infected arthroplasty cases are considerable, with significantly worse functional outcomes reported. New methods of infection prevention are required. HINS-light is a novel blue light inactivation technology which kills bacteria through a photodynamic process. The aim of this study was to investigate the efficacy of HINS-light for the inactivation of bacteria isolated from infected arthroplasty cases. Specimens from hip and knee arthroplasty infections are routinely collected to identify causative organisms. This study tested a range of these isolates for sensitivity to HINS-light. During testing, bacterial suspensions were exposed to increasing doses of HINS-light of (123 mW/cm. 2. irradiance). Non-light exposed control samples were also set-up. Bacterial samples were then plated onto agar plates and incubated at 37°C for 24 hours before enumeration. Complete inactivation (greater than a 4-log reduction) was achieved for all of the clinical isolates from infected arthroplasty cases. The typical inactivation curve showed a slow initial reaction followed by a period of rapid inactivation. The doses of HINS-light exposure required ranged from 118–2214 J/cm. 2. respectively. Gram-positive bacteria were generally found to be more susceptible than Gram-negative. This study has demonstrated that HINS-light successfully inactivated all clinical isolates from infected arthroplasty cases. As HINS-light utilises visible-light wavelengths it can be safely used in the presence of patients and staff. This unique feature could lead to possible applications such as use as an infection prevention tool during surgery and post-operative
Flexion Deformity of knee is the most common deformity in post polio residual deformity. Wilson's release, supracondylar osteotomy etc have been described for its treatment. We present our result of fractional hamstring lengthening followed by gradual distraction using threaded rod in hollow tube to treat flexion deformity of knee. This retrospective study included 150 cases (80 males and 70 females) with the mean of 15 years (8-22yrs). The mean duration of deformity was 6 years (2 – 14yrs) with mean follow up 0f 3 years. The mean preoperative flexion deformity was 45degree (110 – 30 degree) with a mean pre operative further flexion of 110 degree (130 – 90) .20 cases were had a crawling gait and 10 cases were wheel chair bound. Flexion got corrected to 0 degree in 110 cases (P value <0.01). Post operative mean arc of motion was 80degree We had 10 cases who could not tolerate plaster and hence were put on traction . 20 cases had knee stiffness on removal of plaster which could not improve on physiotherapy. 10 cases had superficial infection cured with
Introduction. Primary Total Elbow Replacement (TER) is gaining popularity as a primary treatment option for osteoporotic fractures of the elbow, particularly in patients with low demand. The aim of this study was to assess the clinical and functional efficacy of TER as a primary treatment for comminuted distal humerus fractures in the elderly. Methods. We retrospectively reviewed twenty-three patients (22 females and 1 male) who were treated with primary total elbow replacement for complex, intra-articular fractures of the distal humerus in the elderly between March 2000 and January 2010. The average age of the patients was seventy-five years (ranging from 66 to 94 years). Postoperative elbow function was assessed using the Mayo Elbow Performance Score. The radiological assessment was performed using antero-posterior and lateral radiographs done at follow-up appointments. Results. The average duration of follow up was 6 years. Overall, the mean Mayo elbow performance score was 93 points out of 100. The arc of flexion averaged at 94.3degrees. One patient developed blisters at her arm postoperatively but resolved with
Crown copyright 2009. Published with the (permission of the Defence Science and Technology Laboratory on behalf of the Controller of HMSO. Introduction. The optimum strategy for the care of war wounds is yet to be established. A need exists to model complex extremity injury, allowing investigation of wound management options. Aim. To develop a model of militarily relevant extremity wounding. Study Design. Laboratory study with New Zealand White Rabbits. Methods. Phase 1. Development of injury. Following induction of general anaesthesia, a muscle belly on the flexor aspect of the forelimb of the rabbit was exposed. This was achieved by creating a fascial tunnel under the belly of flexor carpi ulnaris (FCU). Utilising a custom built drop test rig a high energy, short duration impact was delivered. To replicate casualty evacuation timelines, the animal was maintained under anaesthesia for three hours and recovered. The wound was dressed with saline soaked gauze and supportive bandaging. 48 hrs later, the animal was culled and the muscle harvested for histological analysis. Analgesia was administered once a day. Animals were checked by experienced staff at least twice a day and body temperature recorded by a subcutaneous transponder. Phase 2. Contamination of muscle injury. Sequential animals had inoculums of 1×102/100μl, 1×106/100μl and 1×108/100μl of Staphylococcus aureus administered to the muscle immediately after injury. Animals were recovered from anaesthetic and monitored as per phase 1. Delivery was evaluated by droplet spread and via injection by fine bore needle into the muscle belly. At the 48 hour point, the animals were culled,
The period of post-operative treatment before surgical wounds
are completely closed remains a key window, during which one can
apply new technologies that can minimise complications. One such
technology is the use of negative pressure wound therapy to manage
and accelerate healing of the closed incisional wound (incisional
NPWT). We undertook a literature review of this emerging indication
to identify evidence within orthopaedic surgery and other surgical
disciplines. Literature that supports our current understanding
of the mechanisms of action was also reviewed in detail. Objectives
Methods