Advertisement for orthosearch.org.uk
Results 1 - 5 of 5
Results per page:
Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_2 | Pages 91 - 91
10 Feb 2023
Schwer E Grant J Taylor D Hewitt J Blyth P
Full Access

The triangular fibrocartilage complex (TFCC) is a known stabiliser of the distal radioulnar joint (DRUJ). An injury to these structures can result in significant disability including pain, weakness and joint stiffness. The contribution each of its components makes to the stability of the TFCC is not well understood. This study was undertaken to investigate the role of the individual ligaments of the TFCC and their contribution to joint stability. The study was undertaken in two parts. 30 cadaveric forearms were studied in each group. The ligaments of the TFCC were progressively sectioned and the resulting effect on the stability of the DRUJ was measured. A custom jig was created to apply a 20N force through the distal radius, with the ulna fixed. Experiment one measured the effect on DRUJ translation after TFCC sectioning. Experiment two added the measurement of rotational instability. Part one of the study showed that complete sectioning of the TFCC caused a mean increase in translation of 6.09(±3) mm. Sectioning the palmar radioulnar ligament of the TFCC caused the most translation. Part two demonstrated a change in rotation with a mean of 18 (± 6) degrees following sectioning of the TFCC. There was a progressive increase in rotational instability until the palmar radioulnar ligament was also sectioned. Linear translation consistently increased after sectioning all of the TFCC ligaments, confirming its importance for DRUJ stability. Sectioning of the palmar radioulnar ligament most commonly caused the greatest degree of translation. This suggests injury to this ligament would more likely result in a greater degree of translational instability. The increase in rotation also suggests that this type of instability would be symptomatic in a TFCC injury


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_21 | Pages 49 - 49
1 Dec 2016
Lalone E Gammon B Willing R Nishiwaki M Johnson J King G
Full Access

Altered distal radioulnar joint contact (DRUJ) mechanics are thought to cause degenerative changes in the joint following injury. Much of the current research examining DRUJ arthrokinematics focuses on the effect of joint malalignment and resultant degenerative changes. Little is known regarding native cartilage contact mechanics in the distal radioulnar joint. Moreover, current techniques used to measure joint contact rely on invasive procedures and are limited to statically loaded positions. The purpose of this study was to examine native distal radioulnar joint contact mechanics during simulated active and passive forearm rotation using a non-invasive imaging approach. Testing was performed using 8 fresh frozen cadaveric specimens (6 men: 2 women, mean age 62 years) with no CT evidence of osteoarthritis. The specimens were thawed and surgically prepared for biomechanical testing by isolating the tendons of relevant muscles involved in forearm rotation. The humerus was then rigidly secured to a wrist simulator allowing for simulated active and passive forearm rotation. Three-dimensional (3D) cartilage surface reconstructions of the distal radius and ulna were created using volumetric data acquired from computed tomography after joint disarticulation. Using optically tracked motion data and 3D surface reconstructions, the relative position of the cartilage models was rendered and used to measure DRUJ cartilage contact mechanics. The results of this study indicate that contact area was maximal in the DRUJ at 10 degrees of supination (p=0.002). There was more contact area in supination than pronation for both active (p=0.005) and passive (p=0.027) forearm rotation. There was no statistically significant difference in the size of the DRUJ contact patch when comparing analogous rotation angles for simulated active and passive forearm motion (p=0.55). The contact centroid moved 10.5±2.6 mm volar along the volar-dorsal axis during simulated active supination. Along the proximal-distal axis, the contact centroid moved 5.7±2.4 mm proximal during simulated active supination. Using the technique employed in this study, it was possible to non-invasively examine joint cartilage contact mechanics of the distal radioulnar joint while undergoing simulated, continuous active and passive forearm rotation. Overall, there were higher contact area values in supination compared with pronation, with a peak at 10 degrees of supination. The contact centroid moved volarly and proximally with supination. There was no difference in the measured cartilage contact area when comparing active and passive forearm rotation. This study gives new insight into the changes in contact patterns at the native distal radioulnar joint during simulated forearm rotation, and has implications for increasing our understanding of altered joint contact mechanics in the setting of deformity


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_13 | Pages 5 - 5
1 Dec 2022
Li T Beaudry E Westover L Chan R
Full Access

The Adams-Berger reconstruction is an effective technique for treating distal radioulnar joint (DRUJ) instability. Graft preparation techniques vary amongst surgeons with insufficient evidence to support one technique over another. Our study evaluated the biomechanical properties of four graft preparation techniques. Extensor tendons were harvested from fresh frozen porcine trotters obtained from a local butcher shop and prepared in one of three configurations (n=5 per group): tendon only; tendon prepared with non-locking, running suture (2-0 FiberLoop, Arthrex, Naples, FL) spaced at 6 mm intervals; and tendon prepared with suture spaced at 12 mm intervals. A fourth configuration of suture alone was also tested. Tendons were allocated in a manner to ensure comparable average diameters amongst groups. Biomechanical testing occurred using custom jigs simulating radial and ulnar tunnels attached to a Bose Electroforce 3510 mechanical testing machine (TA Instruments). After being woven through the jigs, all tendons were sutured end-to-end with 2-0 PROLENE suture (Ethicon). Tendons then underwent a staircase cyclic loading protocol (5-25 Newtons [N] at 1 hertz [Hz] for 1000 cycles, then 5-50 N at 1 Hz for 1000 cycles, then 5-75 N at 1 Hz for 1000 cycles) until graft failure; if samples did not fail during the protocol, they were then loaded to failure. Samples were visually inspected for mode of failure after the protocol. A one-way analysis of variance was used to compare average tendon diameter; post-hac Tuhey tests were used to compare elongation and elongation rate. Survival to cyclic loading was analyzed using Kaplan-Meier survival curves with log rank. Statistical significance was set at a = 0.05. The average tendon diameter of each group was not statistically different [4.17 mm (tendon only), 4.33 mm (FiberLoop spaced 6 mm), and 4.30 mm (FiberLoop spaced 12 mm)]. The average survival of tendon augmented with FiberLoop was significantly higher than tendon only, and all groups had significantly improved survival compared to suture only. There was no difference in survival between FiberLoop spaced 6 mm and 12 mm. Elongation was significantly lower with suture compared to tendon augmented with FiberLoop spaced 6 mm. Elongation rate was significantly lower with suture compared to all groups. Modes of failure included rupture of the tendon, suture, or both at the simulated bone and suture and/or tendon interface, and elongation of the entire construct without rupture. In this biomechanical study, augmentation of porcine tendons with FiberLoop suture spaced at either 6 or 12 mm for DRUJ reconstruction significantly increased survival to a staircase cyclic loading protocol, as suture material was significantly stiffer than any of the tendon graft configurations


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_3 | Pages 14 - 14
1 Mar 2021
Au K Gammon B Undurraga S Culliton K Louati H D'Sa H
Full Access

The clinical diagnosis of distal radioulnar joint (DRUJ) instability remains challenging. The current diagnostic gold standard is a dynamic computerized topography (CT) scan. This investigation compares the affected and normal wrists in multiple static positions of forearm rotation.. However, its accuracy has been questioned, as the wrist is unloaded and not placed under stress. This may fail to capture DRUJ instability that does not result in static malalignment between the ulnar head and sigmoid notch. The purpose of this biomechanical study was to evaluate the effectiveness of both dynamic and stress CT scans in detecting DRUJ instability. A customized DRUJ arthrometer was designed that allows for both static positioning, as well as dorsal and volar loading at the DRUJ in various degrees of forearm rotation. Ten fresh frozen cadavers were prepared and mounted in the apparatus. CT scans were performed both in the unloaded condition (dynamic CT) and with each arm subjected to a standardized 50N volar and dorsal force (stress CT) in neutral and maximum pronation/ supination. The TFCC (triangular fibrocartilage complex)was then sectioned peripherally to simulate DRUJ instability and the methodology was repeated. CT scans were then evaluated for displacement using the radioulnar ratio method. When calculating the radioulnar ratio for intact wrists using the dynamic CT technique, values were 0.50, 0.64, 0.34 for neutral, pronation and supination, respectively. When the TFCC was sectioned and protocol repeated, the values for the simulated unstable wrist for dynamic CT were 0.54, 0.62, 0.34 for neutral, pronation and supination, respectively. There was no statistically significant difference between the intact and sectioned states for any position of forearm rotation using dynamic CT. Usingstress CT, mean radioulnar ratios for the intact specimens were calculated to be 0.44, 0.36 and 0.31 for neutral, pronation and supination, respectively. After sectioning the TFCC, the radioulnar ratios increased to 0.61, 0.39 and 0.46 for neutral, pronation and supination. There was a statistically significant difference between intact and simulated-unstable wrists in supination (p = 0.002) and in neutral (p=0.003). The radioulnar ratio values used to measure DRUJ translation for dynamic CT scans were unable to detect a statistically significant difference between stable and simulated unstable wrists. This was true for all positions of forearm rotation. However, when a standard load was placed across the DRUJ, statically significant changes in the radioulnar ratio were seen in neutral and supination between stable and simulated unstable wrists. This discrepancy challenges the current gold standard of dynamic CT in its ability to accurately diagnosis DRUJ instability. It also introduces stress CT as a possible solution for diagnosing DRUJ instability from peripheral TFCC lesions


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_1 | Pages 82 - 82
1 Jan 2013
Mahajan R Sung-Jae K Rajgopalan S Mestha P
Full Access

The recognition of the role of TFCC as a major distal radioulnar joint stabilizer and a buffer to compressive forces indicates the importance of preserving as much of this structure as possible. We developed arthroscopic technique for repair of Palmer I B tears of TFCC using a hypodermic needle which obviates the need of any additional skin incision. With wrist under traction important landmarks like radial styloid process, ulnar styloid process, Lister's tubercle and extensor tendons are marked using skin marker. For placement of the arthroscope, 3–4 portal is used and for instruments 6 R and 6 U portals are used. An outside-in technique is used. A 19 G needle is inserted upward from 5mm proximal to the level of the 6 R portal through skin, subcutaneous tissue, capsular tissue and then through the 2mm inner side of detached area of TFCC, while stabilizing it with probe. A 2–0 polydioxanone-PDS suture is passed through needle and caught by grasper placed in the 6 R portal. Now needle is withdrawn and then suture is retrieved out of the joint through the 6 R portal. The procedure is repeated for required number of sutures for dorsal part of peripheral tear. Thus we have stitches with one limb exiting the joint through portal and the other limb entering the joint percutaneously. A small mosquito forceps is passed through the 6 R portal undermining subcutaneous area and these percutaneously passing limbs of sutures are withdrawn through the portal. Now we have sutures entering and exiting through the 6 R portal. Similar procedure is done for ulnar part of peripheral tear through the 6 U portal. Knots are tied and slid beneath the subcutaneous tissue. It offers advantages of a lower risk of neurovascular damage, reduced postoperative pain, faster rehabilitation and better cosmesis