Advertisement for orthosearch.org.uk
Results 1 - 20 of 347
Results per page:
Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 2 - 2
1 Sep 2012
Wuestemann T Bastian A Parvizi J Nessler J Kolisek F Nevelos J
Full Access

Introduction. The origins of the uncemented tapered wedge hip stem design currently offered by several orthopaedic device companies can be linked back to the cemented Straight Mueller type stem design first used in 1977. The design, a wedge shape with a taper angle of 6 degrees, maintains a single medial curvature for all sizes and increases laterally in the width to accommodate different size femurs. Although evolutionary improvements have been made over the years the basic body geometry of the stem has stayed mainly unchanged with excellent clinical survivorship. Over the past decade, the demographics of hip replacement have changed, with a large increase in younger male patients in the age range of 40 to 60 years. In this study the femoral fit of a novel tapered stem, designed to fit a wide array of patient types, is compared to a standard predicate tapered stem design. Methods. A bone morphology study was performed on a patient population of 556 patients using three dimensional digital data from CT-scans. To characterize the fit of the stem designs we analyzed the ratio of a distal (60mm below lesser trochanter) and a proximal (10mm above lesser trochanter) cross section. The same measurements were taken with the standard tapered stem design and the novel tapered stem design, with a given constant implantation height of 20mm above the lesser trochanter. The fit of the stems was classified as Type 1, where there was both proximal and distal engagement, Type 2, proximal engagement only, Type 3, distal engagement only. The distal and proximal engagement, Type 1, was specified with a maximum engagement difference of 2mm proximal to distal. Results. The standard tapered stem showed a well balanced distal to proximal ratio in the median sizes. However, with increasing stem size the distal engagement increases. The novel tapered stem design showed a well balanced proximal to distal ratio throughout the complete size range. With respect to Type 3 fit classification the novel tapered stem design showed a reduced percentage of distal engagements (2.8%) compared to the predicate standard stem (17.2%). In the 40 to 60 year old male group the distal engagements for the standard stem increases (28.2%), whereas the distal engagements for the novel stem remains unchanged (1.3%). Discussion. The cementless, tapered wedge stem design is used in large numbers globally due to its ease of use and reproducibility. However, changing patient demographics and associated bone morphology represents a challenge for existing designs to achieve a proximal fit. The novel tapered stem design presented here was adapted to these influencing factors by optimizing the proximal to distal ratio with respect to the whole patient group resulting in a particularly marked improvement in proximal fit in the male 40–60 age group compared to predicate stem designs


The Bone & Joint Journal
Vol. 97-B, Issue 1 | Pages 94 - 99
1 Jan 2015
Grammatopoulos G Wilson HA Kendrick BJL Pulford EC Lippett J Deakin M Andrade AJ Kambouroglou G

National Institute of Clinical Excellence guidelines state that cemented stems with an Orthopaedic Data Evaluation Panel (ODEP) rating of > 3B should be used for hemiarthroplasty when treating an intracapsular fracture of the femoral neck. These recommendations are based on studies in which most, if not all stems, did not hold such a rating. . This case-control study compared the outcome of hemiarthroplasty using a cemented (Exeter) or uncemented (Corail) femoral stem. These are the two prostheses most commonly used in hip arthroplasty in the UK. Data were obtained from two centres; most patients had undergone hemiarthroplasty using a cemented Exeter stem (n = 292/412). Patients were matched for all factors that have been shown to influence mortality after an intracapsular fracture of the neck of the femur. Outcome measures included: complications, re-operations and mortality rates at two, seven, 30 and 365 days post-operatively. Comparable outcomes for the two stems were seen. . There were more intra-operative complications in the uncemented group (13% vs 0%), but the cemented group had a greater mortality in the early post-operative period (n = 6). There was no overall difference in the rate of re-operation (5%) or death (365 days: 26%) between the two groups at any time post-operatively. This study therefore supports the use of both cemented and uncemented stems of proven design, with an ODEP rating of 10A, in patients with an intracapsular fracture of the neck of the femur. Cite this article: Bone Joint J 2015;97-B:94–9


Introduction. Short-segment posterior instrumentation for spine fractures is threatened by unacceptable failure rates. Two important design objectives of pedicle screws, bending and pullout strength, may conflict with each other. Hypothesis. Multiobjective optimization study with artificial neural network (ANN) algorithm and genetic algorithm (GA). Materials & Methods. Three-dimensional finite element (FE) methods were applied to investigate the optimal designs of pedicle screws with an outer diameter of 7 mm using a multiobjective approach for these two objectives. Based on the FE results on an L25 orthogonal array, two objective functions were developed by an ANN algorithm. Then, the trade-off solutions known as Pareto optima were explored by a GA. The optimal design was validated by mechanical tests. Results. The knee solutions of the Pareto fronts had simultaneous high bending and pullout strength ranging from 92 to 94 percent of their maxima. The corresponding range of the design parameters was 3.8 to 4.06 mm for inner diameter and 3.21 to 3.3 mm for pitch; 0 mm for beginning position of conical angle, 0.4 mm for proximal root radius, 5 degrees for proximal half angle, and 0.1 mm for thread width. The optimal design was well validated by mechanical tests, comparing with commercially available pedicle screws. Discussion & Conclusions. The optimal design of pedicle screws obtained could achieve an ideal with high mechanical performance in both bending and pullout tests


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_16 | Pages 13 - 13
1 Apr 2013
Hoffmann S Paetzold R Mair S Stephan D Buehren V Augat P
Full Access

Hypothesis. The proximal geometry and design of trochanteric nails affects initial construct stiffness, fatigue survival, and preservation of biomechanical stability over time. Materials & Methods. Eight pairs of human cadaveric femora were implanted with two different short intramedullary nails with (Intertan, (S&N)) and without (Gamma 3, (Stryker)) interlocking lag screws. Femoral osteotomies were performed to generate a pertrochanteric multifragmentary unstable fracture (OTA 31-A 2.2). The bones were tested in a cyclic testing protocol with increasing loads of 100 N every 20.000 cycles (start point 50/500 N) simulating one leg stance. The position of the femur was 10° adduction and 10° extension. Stiffness, failure load, and cycles to failure were measured. Results. Initially, stiffness of the interlocking lag screw nail was 40 % higher (p < 0,05) than for the non-interlocking nail. During the test, the difference in stiffness gradually decreased. Load to failure (9 %, p < 0,05) and cycles to failure (13 %, p < 0,05) were also higher for the interlocking nail construct. Discussion & Conclusion. The interlocking screw design of intramedullary nail constructs improves the mechanical performance in unstable trochanteric fractures. This may result in improved clinical performance


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 241 - 241
1 Sep 2012
Field R Rajakulendran K Rushton N
Full Access

Introduction. The MITCH PCR is an anatomic, flexible, horse-shoe shaped acetabular component, with 2 polar fins. The rationale of the PCR cup design is to reproduce a near-physiological stress distribution in the bone adjacent to the prosthesis. The thin composite cup is designed to fuse and flex in harmony with the surrounding bony structure. Only the pathological acetabular cartilage and underlying subchondral bone of the horseshoe-shaped, load-bearing portion of the acetabular socket is replaced, thus preserving viable bone stock. The PCR is manufactured from injection moulded carbon fibre reinforced polyetheretherketone (PEEK), with a two layer outer surface comprising hydroxyapatite and plasma sprayed commercially pure titanium. It is implanted in conjunction with a large diameter low wear femoral head, producing a bearing that will generate minimal wear debris with relatively inert particles. Pre-clinical mechanical testing, finite element analysis and biocompatibility studies have been undertaken. FEA evaluation predicts preservation of host bone density in the load bearing segments. A pilot clinical study was completed on a proto-type version of the PCR cup (the “Cambridge” cup), achieving excellent 5 and 10 year results. Subjects and Methods. We report the three-year results from a two-centre, prospective clinical evaluation study of the MITCH PCR cup. Patient outcome has been assessed using standardised clinical and radiological examinations and validated questionnaires. The change in physical level of activity and quality of life has been assessed using the Oxford Hip Score, Harris Hip score and the EuroQol-5D score, at scheduled time-points. Serial radiographs have been analysed to monitor the fixation and stability of the components. Results and Conclusions. In total 25 PCR cups were implanted by 3 surgeons. There were 12 men and 13 women. The mean patient age at time of surgery was 67 years (range 57–74). An Accolade TMZF stem was used as the femoral component in 19 patients and an Exeter stem in 6. The mean Oxford Hip score improved from 19.8 pre-operatively to 45 at the latest follow-up. The mean Euroqol-5D score improved from 62.6 to 83.6 and the Harris Hip score improved from 49.9 to 90.6. Three adverse events were noted in 2 patients (2 chest infections and 1 deep vein thrombosis). One revision of the acetabular component was performed at 21 months for squeaking. This has been investigated and modification of the articular geometry has resolved the problem on in-vitro testing


The Bone & Joint Journal
Vol. 99-B, Issue 4 | Pages 503 - 507
1 Apr 2017
White TO Mackenzie SP Carter TH Jefferies JG Prescott OR Duckworth AD Keating JF

Aims

Fracture clinics are often characterised by the referral of large numbers of unselected patients with minor injuries not requiring investigation or intervention, long waiting times and recurrent unnecessary reviews. Our experience had been of an unsustainable system and we implemented a ‘Trauma Triage Clinic’ (TTC) in order to rationalise and regulate access to our fracture service. The British Orthopaedic Association’s guidelines have required a prospective evaluation of this change of practice, and we report our experience and results.

Patients and Methods

We review the management of all 12 069 patients referred to our service in the calendar year 2014, with a minimum of one year follow-up during the calendar year 2015.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_33 | Pages 8 - 8
1 Sep 2013
Scott C Eaton M Nutton R Wade F Pankaj P Evans S
Full Access

Joint registries report that 25–40% of UKR revisions are performed for pain. Proximal tibial strain and microdamage are possible causes of this “unexplained” pain. The aim of this study was to examine the effect of UKR implant design and material on proximal tibial cortical strain and cancellous microdamage. Composite Sawbone tibias were implanted with cemented UKR components: 5 fixed bearing all-polyethylene (FB-AP), 5 fixed bearing metal backed (FB-MB), and 5 mobile bearing metal backed implants (MB-MB). Five intact tibias were used as controls. Tibias were loaded in 500N increments to 2500N. Cortical surface strain was measured using digital image correlation (DIC). Cancellous microdamage was measured using acoustic emission (AE), a technique which detects elastic waves produced by the rapid release of energy during microdamage events. DIC showed significant differences in anteromedial cortical strain between implants at 1500N and 2500N in the proximal 10mm only (p<0.001) with strain shielding in metal backed implants. AE showed significant differences in cancellous microdamage (AE hits), between implants at all loads (p=0.001). FB-AP implants displayed significantly more hits at all loads than both controls and metal backed implants (p<0.001). FB-AP implants also differed significantly by displaying AE hits on unloading (p=0.01), reflecting a lack of implant stiffness. Compared to controls, the FB-AP implant displayed 15x the total AE hits, the FB-MB 6x and the MB-MB 2.7x. All-polyethylene medial UKR implants are associated with greater cancellous bone microdamage than metal backed implants even at low loads


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 509 - 509
1 Sep 2012
Thomas G Hossain M Monk A Gill H Glyn-Jones S Andrew J Murray D Beard D Epos Group N
Full Access

Introduction. Malalignment of some designs of stem is associated with an increased risk of aseptic loosening and revision. We investigated whether the alignment of the cemented polished, double-taper design adversely affected outcome, in a multicentre prospective study. Methods. A multicentre prospective study of 1189 total hip replacements was undertaken to investigate whether there is an association between surgical outcome and femoral stem alignment. All patients underwent a primary THR with the Exeter femoral stem (Stryker Howmedica Osteonics, Mahwah, NJ) and a variety of acetabular components. The primary outcome measure was the Oxford hip score (OHS) and change in OHS at five years. Secondary outcomes included rate of dislocation and revision. Radiographic evaluation of the femoral component was also undertaken. The long axis of the Exeter femoral component and the long axis of the femoral canal were located, and the angle at the point of intersection measured. The cementing quality was determined as defined by Barrack et al. Radiolucent lines at the cement-stem and cement-bone interface in the five year radiographs were defined using the zones described by Gruen et al. Subsidence was measured as the vertical dimension of the radiolucency craniolateral to the shoulder of the stem in Gruen zone 1 as described by Fowler et al. Cement fractures were recorded. Results. The incidence of varus (>5 ° to the femoral axis), and valgus (>5 °) malignment were 3.7% and 0.8% respectively. Pre-operative demographics and OHS were similar in all groups (p > 0.4). There was no significant difference in OHS or change in OHS between neutral and malaligned groups at 5 years (neutral, mean=40.1, change=23.1; varus, mean=40.1, change=23.7; valgus, mean=42.0, change=26.6; p=0.46 and p=0.45 respectively). There was no significant difference in dislocation rate between the groups (p=0.66). There was also no significant difference in revision rate (p=0.34). There were no statistically significant differences in the incidence of femoral radiolucency, stem subsidence or cement fracture (p > 0.1). Conclusion. This study provides evidence that both varus and valgus implantation does not compromise the short to medium term clinical results of the cemented, polished, double-taper stems. Longer follow-up is required to establish the influence of stem alignment on the incidence of aseptic loosening and revision


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 58 - 58
1 Sep 2012
Migaud H Amzallag M Pasquier G Gougeon F Vasseur L Miletic B Girard J
Full Access

Introduction. In valgus knees, ligament balance remain difficult when implanting a total knee arthroplasty (TKA), this leads some authors to systematically propose the use of constrained devices. Others prefer reserving higher constraints to cases where it is not possible to obtain final satisfactory balance: less than 5 of residual frontal laxity in extension in each compartment, and a tibiofemoral gap difference not in excess to 3mm between flexion and extension. The goal of the study was to assess if is possible to establish preoperative criteria that can predict a constrained design prosthetic implantation at surgery. Materials and Methods. A consecutive series of 93 total knee prostheses, implanted to treat a valgus deformity of more than 5 was retrospectively analysed. Preoperatively, full weight bearing long axis AP views A-P were performed: hip knee angle (HKA) averaged 195 (186 to 226), 36 knees had more than 15 of valgus, and 19 others more than 20 of valgus. Laxity was measured by stress radiographies with a TelosTM system at 100 N. Fifty-two knees had preoperative laxity in the coronal plane of more than 10. Fourteen knees had more than 5 laxity on the convex (medial) side, 21 knees had more than 10 laxity on the concave (lateral) side. Statistical assessment, using univariate analysis, identified the factors that led, at surgery, to an elevated constraint selection level; these factors of independence were tested by multivariate analysis. Logistical regression permitted the classification of the said factors by their odds ratios (OR). Results. High-constraints prostheses (CCK type) were used in 26 out of 93 TKA, the other TKA were regular posterostabilized (PS) prostheses. Statistically, the preoperative factors that led to the choice of a constrained prosthesis were: (1) valgus severity as measured by HKA (PS = (PS = 193, CCK = 198), (2) increased posterior tibial slope (PS = 4.8, CCK = 6.5), (3) low patellar height (using Blackburne and Peel index PS = 0.89, CCK = 0.77), (4) severity of laxity in valgus (PS = 2.3, CCK = 4.3). Among all these factors, the only independent one was laxity in valgus (convex side laxity) (p = 0.0008). OR analysis showed a two-fold increased probability of implanting an elevated constraints prosthesis for each one degree increment of laxity in valgus. Discussion. This study demonstrated that it was not the valgus angle severity but rather the convex medial side laxity that increased the frequency of constrained prostheses implantation. Other factors, as a low patellar height or an elevated posterior tibial slope, when associated, potentiate this possible prosthetic switch (to higher constraints) and should make surgeons aware, in these situations, of encountering difficulties when establishing ligament balance


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_8 | Pages 15 - 15
1 Feb 2013
Ramasamy A Masouros S Newell N Bonner T West A Hill A Clasper J Bull A
Full Access

Current military conflicts are characterised by the use of the Improvised Explosive Device (IED). Improvements in personal protection, medical care and evacuation logistics have resulted in increasing numbers of casualties surviving with complex musculoskeletal injuries, often leading to life-long disability. Thus, there exists an urgent requirement to investigate the mechanism of extremity injury caused by these devices in order to develop mitigation strategies. In addition, the wounds of war are no longer restricted to the battlefield; similar injuries can be witnessed in civilian centres following a terrorist attack.

Key to mitigating such injuries is the ability to deconstruct the complexities of an explosive event into a controlled, laboratory-based environment. In this study, an anti-vehicle underbelly injury simulator, capable of recreating in the laboratory the impulse from an anti-vehicle (AV) explosion, is presented and characterised. Tests were then conducted to assess the simulator's ability to interact with human cadaveric legs. Two mounting conditions were assessed, simulating a typical seated and standing vehicle passenger using instrumented cadaveric lower limbs.

This experimental device, will now allow us (a) to gain comprehensive understanding of the load-transfer mechanisms through the lower limb, (b) to characterise the dissipating capacity of mitigation technologies, and (c) to assess the biofidelity of surrogates.


Bone & Joint Open
Vol. 4, Issue 9 | Pages 659 - 667
1 Sep 2023
Nasser AAHH Osman K Chauhan GS Prakash R Handford C Nandra RS Mahmood A

Aims. Periprosthetic fractures (PPFs) following hip arthroplasty are complex injuries. This study evaluates patient demographic characteristics, management, outcomes, and risk factors associated with PPF subtypes over a decade. Methods. Using a multicentre collaborative study design, independent of registry data, we identified adults from 29 centres with PPFs around the hip between January 2010 and December 2019. Radiographs were assessed for the Unified Classification System (UCS) grade. Patient and injury characteristics, management, and outcomes were compared between UCS grades. A multinomial logistic regression was performed to estimate relative risk ratios (RRR) of variables on UCS grade


The Bone & Joint Journal
Vol. 106-B, Issue 4 | Pages 401 - 411
1 Apr 2024
Carrothers A O'Leary R Hull P Chou D Alsousou J Queally J Bond SJ Costa ML

Aims. To assess the feasibility of a randomized controlled trial (RCT) that compares three treatments for acetabular fractures in older patients: surgical fixation, surgical fixation and hip arthroplasty (fix-and-replace), and non-surgical treatment. Methods. Patients were recruited from seven UK NHS centres and randomized to a three-arm pilot trial if aged older than 60 years and had a displaced acetabular fracture. Feasibility outcomes included patients’ willingness to participate, clinicians’ capability to recruit, and dropout rates. The primary clinical outcome measure was the EuroQol five-dimension questionnaire (EQ-5D) at six months. Secondary outcomes were Oxford Hip Score, Disability Rating Index, blood loss, and radiological and mobility assessments. Results. Between December 2017 and December 2019, 60 patients were recruited (median age 77.4 years, range 63.3 to 88.5) (39/21 M/F ratio). At final nine-month follow-up, 4/60 (7%) had withdrawn, 4/60 (7%) had died, and one had been lost to follow-up; a 98% response rate (50/51) was achieved for the EQ-5D questionnaire. Four deaths were recorded during the three-year trial period: three in the non-surgical treatment group and one in the fix-and-replace group. Conclusion. This study has shown a full-scale RCT to be feasible, but will need international recruitment. The Acetabular Fractures in older patients Intervention Trial (AceFIT) has informed the design of a multinational RCT sample size of 1,474 or 1,974 patients for a minimal clinically important difference of 0.06 on EQ-5D, with a power of 0.8 or 0.9, and loss to follow-up of 20%. This observed patient cohort comprises a medically complex group requiring multidisciplinary care; surgeon, anaesthetist, and ortho-geriatrician input is needed to optimize recovery and rehabilitation. Cite this article: Bone Joint J 2024;106-B(4):401–411


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_5 | Pages 12 - 12
13 Mar 2023
Harding T Dunn J Haddon A Fraser E Sinnerton R Davies P Clift B
Full Access

COVID 19 led to massive disruption of elective services across Scotland. This study was designed to assess the impact on elective service that the COVID-19 pandemic had, to what extent services have been restarted and the associated risks are in doing so. This is a retrospective observational study. The primary outcomes are the number of operations completed, 30-day mortality, 30-day complication rates and nosocomial infection with COVID-19 compared to previous years. Data was collected from 4 regions across Scotland from 27th March 2020 - 26th March 2021. This was compared to the same time period the previous year. 3431 elective operations were completed in the year post-pandemic compared with 12255, demonstrating a reduction of 72%. Both groups had comparable demographics. Major joint arthroplasty saw a 72% reduction, with TKR seeing a reduction of 82%. Each of the 4 health boards were affected in a similar fashion. Nosocomial COVID-19 infection was 0.4% in the post covid group. 30 day mortality was the same at 0.1%. Total complications rose from 5.7% to 10.1% post covid. This study shows that there has been a substantial reduction in elective activity across Scotland that is disproportionate to the level of COVID-19. The risk of developing COVID-19 from elective surgery is low at 0.4%, however all complications saw a significant rise. This is likely multifactorial. This study will inform decision makers in future pandemics, that it is safe to continue elective orthopaedic surgery and of the potential impact of cessation of services


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_4 | Pages 9 - 9
8 Feb 2024
Hall AJ Clement ND Farrow L Kennedy JW Harding T Duckworth AD Maclullich AMJ Walmsley P
Full Access

Periprosthetic femur fracture (PPF) are heterogeneous, complex, and thought to be increasingly prevalent. The aims were to evaluate PPF prevalence, casemix, management, and outcomes. This nationwide study included all PPF patients aged >50 years from 16 Scottish hospitals in 2019. Variables included: demographics; implant and fracture factors; management factors, and outcomes. There were 332 patients, mean age 79.5 years, and 220/332 (66.3%) were female. One-third (37.3%) were ASA1-2 and two-thirds (62.3%) were ASA3+, 91.0% were from home/sheltered housing, and median Clinical Frailty Score was 4.0 (IQR 3.0). Acute medical issues featured in 87/332 (26.2%) and 19/332 (5.7%) had associated injuries. There were 251/332 (75.6%) associated with a proximal femoral implant, of which 232/251 (92.4%) were arthroplasty devices (194/251 [77.3%] total hip, 35/251 [13.9%] hemiarthroplasty, 3/251 [1.2%] resurfacing). There were 81/332 (24.4%) associated with a distal femoral implant (76/81 [93.8%] were total knee arthroplasties). In 38/332 (11.4%) there were implants proximally and distally. Most patients (268/332; 80.7%) were treated surgically, with 174/268 (64.9%) requiring fixation only and 104/268 (38.8%) requiring an arthroplasty or combined solution. Median time to theatre was longer for arthroplasty versus fixation procedures (120 vs 46 hours), and those requiring inter-hospital transfer waited longer (94 vs 48 hours). Barriers to investigating PPF include varied classification, coding challenges, and limitations of existing registries. This is the first study to examine a national PPF cohort and presents important data to guide service design and research. Additional findings relating to fracture patterns, implant types, surgeon skill-mix, and outcomes are reported herein


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_12 | Pages 11 - 11
1 Oct 2021
Turnbull G Nicholson J Marshall C Macdonald D Breusch S Clement N
Full Access

The Olympia femoral stem is a stainless steel, anatomically shaped, polished and three-dimensionally tapered implant designed for use in cemented total hip arthroplasty (THA). The primary aim of this study was to determine the long-term survivorship, radiographic outcome, and patient reported outcome measures (PROMs) of the Olympia stem. Between May 2003 and December 2005, 239 patients (264 THAs) underwent a THA with an Olympia stem in our institution. PROMs were assessed using the Oxford Hip Score (OHS), EuroQol-5 dimensions (EQ-5D) score and patient satisfaction at mean 10-years following THA. Patient records and radiographs were then reviewed at a mean of 16.5 years (SD 0.7, 15.3 to 17.8) following THA to identify occurrence of complications or revision surgery for any cause. Mean patient age at surgery was 68.0 years (SD 10.9, 31–93 years). There were 156 women (65%, 176 THAs). Osteoarthritis was the indication for THA in 204 patients (85%). Stem survivorship at 10 years was 99.2% (95 % confidence interval [CI], 97.9%-100%) and at 15 years was 97.5% (94.6%–100%). The 15-year stem survival for aseptic loosening was 100%. Only one occurrence of peri-prosthetic fracture was identified, with no episodes of dislocation found. At a mean of 10 (SD 0.8, 8.7 –11.3) years follow-up, mean OHS was 39 (SD 10.3, range 7 – 48) and 94% of patients reported being very satisfied or satisfied. The Olympia stem demonstrated excellent 10-year PROMs, very high rates of stem survivorship and negligible peri-prosthetic fracture and dislocation rate at final follow-up beyond 15 years


Bone & Joint Open
Vol. 5, Issue 1 | Pages 46 - 52
19 Jan 2024
Assink N ten Duis K de Vries JPM Witjes MJH Kraeima J Doornberg JN IJpma FFA

Aims

Proper preoperative planning benefits fracture reduction, fixation, and stability in tibial plateau fracture surgery. We developed and clinically implemented a novel workflow for 3D surgical planning including patient-specific drilling guides in tibial plateau fracture surgery.

Methods

A prospective feasibility study was performed in which consecutive tibial plateau fracture patients were treated with 3D surgical planning, including patient-specific drilling guides applied to standard off-the-shelf plates. A postoperative CT scan was obtained to assess whether the screw directions, screw lengths, and plate position were performed according the preoperative planning. Quality of the fracture reduction was assessed by measuring residual intra-articular incongruence (maximum gap and step-off) and compared to a historical matched control group.


Bone & Joint Open
Vol. 5, Issue 6 | Pages 457 - 463
2 Jun 2024
Coviello M Abate A Maccagnano G Ippolito F Nappi V Abbaticchio AM Caiaffa E Caiaffa V

Aims

Proximal femur fractures treatment can involve anterograde nailing with a single or double cephalic screw. An undesirable failure for this fixation is screw cut-out. In a single-screw nail, a tip-apex distance (TAD) greater than 25 mm has been associated with an increased risk of cut-out. The aim of the study was to examine the role of TAD as a risk factor in a cephalic double-screw nail.

Methods

A retrospective study was conducted on 112 patients treated for intertrochanteric femur fracture with a double proximal screw nail (Endovis BA2; EBA2) from January to September 2021. The analyzed variables were age, sex, BMI, comorbidities, fracture type, side, time of surgery, quality of reduction, pre-existing therapy with bisphosphonate for osteoporosis, screw placement in two different views, and TAD. The last follow-up was at 12 months. Logistic regression was used to study the potential factors of screw cut-out, and receiver operating characteristic curve to identify the threshold value.


The Bone & Joint Journal
Vol. 105-B, Issue 9 | Pages 1013 - 1019
1 Sep 2023
Johansen A Hall AJ Ojeda-Thies C Poacher AT Costa ML

Aims

National hip fracture registries audit similar aspects of care but there is variation in the actual data collected; these differences restrict international comparison, benchmarking, and research. The Fragility Fracture Network (FFN) published a revised minimum common dataset (MCD) in 2022 to improve consistency and interoperability. Our aim was to assess compatibility of existing registries with the MCD.

Methods

We compared 17 hip fracture registries covering 20 countries (Argentina; Australia and New Zealand; China; Denmark; England, Wales, and Northern Ireland; Germany; Holland; Ireland; Japan; Mexico; Norway; Pakistan; the Philippines; Scotland; South Korea; Spain; and Sweden), setting each of these against the 20 core and 12 optional fields of the MCD.


Bone & Joint Open
Vol. 4, Issue 6 | Pages 463 - 471
23 Jun 2023
Baldock TE Walshaw T Walker R Wei N Scott S Trompeter AJ Eardley WGP

Aims

This is a multicentre, prospective assessment of a proportion of the overall orthopaedic trauma caseload of the UK. It investigates theatre capacity, cancellations, and time to surgery in a group of hospitals that is representative of the wider population. It identifies barriers to effective practice and will inform system improvements.

Methods

Data capture was by collaborative approach. Patients undergoing procedures from 22 August 2022 and operated on before 31 October 2022 were included. Arm one captured weekly caseload and theatre capacity. Arm two concerned patient and injury demographics, and time to surgery for specific injury groups.


Bone & Joint Open
Vol. 4, Issue 5 | Pages 378 - 384
23 May 2023
Jones CS Eardley WGP Johansen A Inman DS Evans JT

Aims

The aim of this study was to describe services available to patients with periprosthetic femoral fracture (PPFF) in England and Wales, with focus on variation between centres and areas for care improvement.

Methods

This work used data freely available from the National Hip Fracture Database (NHFD) facilities survey in 2021, which asked 21 questions about the care of patients with PPFFs, and nine relating to clinical decision-making around a hypothetical case.