Aims. The current evidence comparing the two most common approaches for reverse total shoulder arthroplasty (rTSA), the deltopectoral and anterosuperior approach, is limited. This study aims to compare the rate of loosening, instability, and implant survival between the two approaches for rTSA using data from the Dutch National Arthroplasty Registry with a minimum follow-up of five years. Methods. All patients in the registry who underwent a primary rTSA between January 2014 and December 2016 using an anterosuperior or
Despite the expansion of arthroscopic surgery
of the shoulder, the open
The October 2023 Shoulder & Elbow Roundup. 360. looks at: Arthroscopic capsular shift surgery in patients with atraumatic shoulder joint instability: a randomized, placebo-controlled trial; Superior capsular reconstruction partially restores native glenohumeral loads in a dynamic model; Gene expression in glenoid articular cartilage varies in acute instability, chronic instability, and osteoarthritis; Intra-articular injection versus interscalene brachial plexus block for acute-phase postoperative pain management after arthroscopic shoulder surgery; Level of pain catastrophizing rehab in subacromial impingement: secondary analyses from a pragmatic randomized controlled trial (the SExSI Trial); Anterosuperior versus
Aims. Despite the expansion of arthroscopic surgery of the shoulder,
the open
Treatment of proximal humerus fractures (PHF) is controversial in many respects, including the choice of surgical approach for fixation when using a locking plate. The classic
Aim. Clavicular osteotomy was described as an adjunct to
The
Fractures and nonunions of the proximal humerus are increasingly treated by open reduction and internal fixation. The extended
Proximal humeral fractures are common fractures that may lead to severe functional disability. In open reduction and internal fixation of these fractures
Purpose: The purpose of this multicentric study was to report results obtained with the Aequalis system using the simple humeral or total prosthesis, at at least two years follow-up in patients with shoulder joint degeneration and non-repairable rotator cuff tears. Material and methods: Sixty-eight Aequalis arthroplasties were performed between 1992 and 1998. Outcome was assessed on the basis of the Constant score and radiological findings. Female gender predominated (78%) in this series with a mean age of 72 years. There were 62 simple humeral implantations and six total shoulder arthroplasties. The
Anatomic and accurate placement of components is a primary goal in all arthroplasty procedures. Unique to total shoulder arthroplasty, challenging glenoid exposure and osteoarthritic glenoid deformity offer significant challenges and impediments to this goal. Despite thorough pre-operative planning strategies and contemporary cannulated pin-based shoulder systems, it is often times still difficult to accurately aim the guide pin to the medial border of the scapula when the deformity is substantial or exposure is difficult. Even small errors in guide pin position can result in problems with final component version, inclination and glenoid vault perforation. In addition, a malpositioned glenoid component has been shown to have a negative impact on implant longevity and clinical performance. Image-based patient specific instrumentation has been available in the lower extremity for nearly a decade with reliable results. The application of similar technology in the shoulder has demonstrated reliable positioning of the guide pin to a pre-operative plan with subsequent accurate placement of the glenoid component. This surgical demonstration will feature one of the currently available CT-based patient specific glenoid guides using a standard
Hemi shoulder arthroplasty is a rather successful procedure although revision surgery due to secondary glenoid erosion is reported in more than 25%. The downside of common shoulder arthroplasty is that in a
Aim. Recent studies have indicated that the presence of P. acnes in the skin of the shoulder and around the acromion is higher than other body regions like the knee or the hip. The aim of this study was to estimate the presence of P. acnes in a real set of primary shoulder arthroplasty, after skin preparation with chlorhexidine and administration of empirical antibiotic therapy. Method. A prospective observational study involving 63 patients undergoing primary shoulder arthroplasty was designed. In all patients two skin biopsies with a 3 mm dermal punch and one subcutaneous tissue sample after surgical incision were obtained. Skin biopsies were obtained at the most anterior part of the surgical wound in case of superior approach and at the upper part in the
Introduction. The use of reverse total shoulder arthroplasty (RSA) is becoming increasingly common in the treatment of rotator cuff arthropathy. In recent years indications for use have expanded to include elderly patients in whom either internal fixation is not possible due to fracture configuration, poor bone quality, or presence of a rotator cuff deficiency. There is however relatively little evidence to support its use in these circumstances. Objective. This study aims to assess the viability of RSA as a salvage procedure in the treatment of complex proximal humeral fractures or irreducible dislocations, quantified in terms of functional outcome, complication rates and patient reported satisfaction. Methods. All patients presenting between January 2011 and December 2013 with a complex 3- or 4-part humeral fracture or a delayed presentation with an irreducible non-acute dislocation, treated with salvage RSA were eligible for inclusion. All operations were performed in a single centre by one of two specialist upper limb surgeons. Standard
This study reviews the use of intramedullary fibular allograft in treating nonunion of the humeral neck in 11 patients. Nine women and two men with a mean age of 76 years (63 to 89) were followed up for a mean of 61 months (14 to 72). The nonunion was exposed through a
Purpose. While reverse shoulder arthroplasty (RSA) corrects vertical muscle imbalance, it cannot restore the horizontal imbalance seen in cuff-deficient shoulders with combined loss of active elevation and external rotation (CLEER). We report the medium-term results of the modified latissimus dorsi/teres major tendon transfer (L'Episcopo procedure) associated with RSA, performed via a single
Introduction: Surgical treatment of most displaced proximal humerus fractures is challenging due to osteoporosis, which makes stable fixation difficult. Locking plates are intended to provide superior mechanical stability. The NCB. ®. -PH (Non-Contact-Bridging for the Proximal Humerus) plate is a locking plate of the latest generation that allows both open and minimally invasive (MI) application. Methods: In a prospective multicenter study 131 patients were treated (n = 78 open, n = 53 MI). The open procedure was performed using a standard
Aims: The purpose of this study was to evaluate the efficacy of the inverted Delta 3 prosthesis in nonreconstructable massive rotator cuff tear. Methods: 31 inverted Delta 3 prostheses were performed between October 1999 and February 2002. The average age was 72.8 years old (65–84) and the average follow-up was 17.8 months (3–36). A
The purpose of this study was to look at the results of using the Copeland surface replacement in the treatment of arthritis of the shoulder. We report the results of 61 Type 3 Copeland surface replacements in 57 patients. Operations were performed in 33 cases of Rheumatoid Arthritis, 27 cases of Osteoarthritis and 1 case of posttraumatic arthritis. Hemiar-throplasty was performed via a
Background. Total Shoulder Arthroplasty (TSA) has been shown to improve the function and pain of patients with severe degeneration. Recently, TSA has been of interest for younger patients with higher post-operative expectations; however, they are treated using traditional surgical approaches and techniques, which, although amenable to the elderly population, may not achieve acceptable results with this new demographic. Specifically, to achieve sufficient visualization, traditional TSA uses the highly invasive