Advertisement for orthosearch.org.uk
Results 1 - 20 of 238
Results per page:
Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_9 | Pages 58 - 58
1 Oct 2020
Mihalko WM Heise G Morrow B Arnholt C Kurtz S
Full Access

Introduction. Pitting damage on implants has been reported and attributed to use of electrocautery. This study aimed to distinguish how different TKA bearing surfaces are susceptible to this type of damage and whether surgeons were aware that this damage can occur. Methods. A survey was sent to Hip and Knee Society members to determine what percentage of adult reconstructive surgeons use electrocautery after implantation of components. Three bearing surfaces for primary TKA were selected: CoCr, Oxinium, and zirconium nitride (ZrN) to be damaged by electrocautery with a monopolar (MP, Bovie) and bipolar (BP, Aquamantys) electrocautery with three different energy settings. A comparison of surface damage and backscatter elemental analysis using SEM was performed. Average roughness (Ra), maximal peak-to-valley height (Rz,), kurtosis (Rk), and skewness (Rsk) measurements were collected using a profilometer (DektakXT, Bruker, Tucson, AZ) with a 2.5µm radius stylus to assess an area of 3.8mm by 3.2mm in the central portion of the area for each MP and BP energy setting used to impart damage to the bearing surfaces. A similar undamaged area for each bearing surface was also measured for roughness parameter comparison. Results. Median Rz and Ra measurements were larger for BP damaged areas compared to MP for all bearing surfaces.(Table 1) The Oxinium surface had the greatest increase in roughness parameters of all three bearing surfaces tested. Survey results indicate that a significant percentage of adult reconstructive surgeons use the electrocautery after implants are in place and are not aware of this type of damage. Backscatter SEM analysis found significant changes for BP damage compared to MP. Conclusion. Our in vitro study determined surface damage caused by electrocautery can have significant effects on the bearing surfaces of implants. Our survey determined many arthroplasty experts are unaware that this damage can occur. For any figures or tables, please contact the authors directly


Bone & Joint Research
Vol. 8, Issue 2 | Pages 65 - 72
1 Feb 2019
Cowie RM Aiken SS Cooper JJ Jennings LM

Objectives. Bone void fillers are increasingly being used for dead space management in arthroplasty revision surgery. The aim of this study was to investigate the influence of calcium sulphate bone void filler (CS-BVF) on the damage and wear of total knee arthroplasty using experimental wear simulation. Methods. A total of 18 fixed-bearing U2 total knee arthroplasty system implants (United Orthopedic Corp., Hsinchu, Taiwan) were used. Implants challenged with CS-BVF were compared with new implants (negative controls) and those intentionally scratched with a diamond stylus (positive controls) representative of severe surface damage (n = 6 for each experimental group). Three million cycles (MC) of experimental simulation were carried out to simulate a walking gait cycle. Wear of the ultra-high-molecular-weight polyethylene (UHMWPE) tibial inserts was measured gravimetrically, and damage to articulating surfaces was assessed using profilometry. Results. There was no significant difference (p  >  0.05) between the wear rate of implants challenged with CS-BVF (3.3 mm. 3. /MC (95% confidence interval (CI) 1.8 to 4.8)) and the wear rate of those not challenged (2.8 mm. 3. /MC (95% CI 1.3 to 4.3)). However, scratching the cobalt-chrome (CoCr) significantly (p < 0.001) increased the wear rate (20.6 mm. 3. /MC (95% CI 15.5 to 25.7)). The mean surface roughness of implants challenged with CS-BVF was equivalent to negative controls both after damage simulation (p = 0.98) and at the conclusion of the study (p = 0.28). Conclusion. When used close to articulating surfaces, a low-hardness, high-purity CS-BVF had no influence on wear. When trapped between the articulating surfaces of a total knee arthroplasty, CS-BVF did not scratch the surface of CoCr femoral components, nor did it increase the wear of UHMWPE tibial inserts compared with undamaged negative controls. Cite this article: R. M. Cowie, S. S. Aiken, J. J. Cooper, L. M. Jennings. The influence of a calcium sulphate bone void filler on the third-body damage and polyethylene wear of total knee arthroplasty. Bone Joint Res 2019;8:65–72. DOI: 10.1302/2046-3758.82.BJR-2018-0146.R1


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 3 | Pages 374 - 379
1 Mar 2010
Kendrick BJL Rout R Bottomley NJ Pandit H Gill HS Price AJ Dodd CAF Murray DW

With medial unicompartmental osteoarthritis (OA) there is occasionally a full-thickness ulcer of the cartilage on the medial side of the lateral femoral condyle. It is not clear whether this should be considered a contraindication to unicompartmental knee replacement (UKR). The aim of this study was to determine why these ulcers occur, and whether they compromise the outcome of UKR. Case studies of knees with medial OA suggest that cartilage lesions on the medial side of the lateral condyle are caused by impingement on the lateral tibial spine as a result of the varus deformity and tibial subluxation. Following UKR the varus and the subluxation are corrected, so that impingement is prevented and the damaged part of the lateral femoral condyle is not transmitting load. An illustrative case report is presented. Out of 769 knees with OA of the medial compartment treated with the Oxford UKR, 59 (7.7%) had partial-thickness cartilage loss and 20 (2.6%) had a full-thickness cartilage deficit on the medial side of the lateral condyle. The mean Oxford Knee Score (OKS) at the last follow-up at a mean of four years was 41.9 (13 to 48) in those with partial-thickness cartilage loss and 41.0 (20 to 48) in those with full-thickness loss. In those with normal or superficially damaged cartilage the mean was 39.5 (5 to 48) and 39.7 (8 to 48), respectively. There were no statistically significant differences between the pre-operative OKS, the final review OKS or of change in the score in the various groups. We conclude that in medial compartment OA, damage to the medial side of the lateral femoral condyle is caused by impingement on the tibial spine and should not be considered a contraindication to an Oxford UKR, even if there is extensive full-thickness ulceration of the cartilage


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXIX | Pages 15 - 15
1 Jul 2012
O'Daly B Morris E Gavin G O'Keane C McGuinness G O'Byrne J
Full Access

This study evaluates high power low frequency ultrasound transmitted via a flat vibrating probe tip as an alternative technology for meniscal debridement in the knee. A limitation of this technology is thermal damage in residual meniscal tissue. An experimental force controlled testing rig was constructed using a 20kHz ultrasonic probe suspended vertically from a load cell. Ex-vivo bovine meniscus samples were harvested from knee joints and cut into uniform 16mm discs. Effect of variation in force (2.5-4.5N) and amplitude of distal tip displacement (242-494μm peak-peak) settings on tissue removal rate (TRR) and penetration rate (PR) was analysed. Temperature elevation in the residual meniscus was measured by embedded thermocouples and residual meniscus histological analysis. The experiment was designed using a response surface quadratic model with input variables treated as continuous, using Design-Expert v.8.0 (Stat-Ease Inc., Minneapolis, MN). Statistical analysis was conducted using PASW Statistics v.18.0 (IBM SPSS Inc., Chicago, IL). As either force or amplitude increases, there is a linear increase in TRR (Mean±SD: 0.9±0.4 to 11.2±4.9mg/s). A corresponding increase is observed in PR (Mean±SD: 0.08±0.04 to 0.73±0.18mm/s). Maximum mean temperatures of 84.6±12.1°C and 52.3±10.9°C were recorded in residual tissue at 2mm and 4mm from the ultrasound probe-tissue interface. Minimum depth of the zone of thermal alteration in residual tissue was 177.4μm. There is an inverse relationship between both amplitude and force, and temperature elevation, with higher amplitude and force settings resulting in less thermal damage. Ultrasonic debridement shows comparable thermal damage to existing meniscal debridement technologies


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_IX | Pages 26 - 26
1 Mar 2012
Gulati A Pandit H Gill HS Price AJ Dodd CAF Murray DW
Full Access

INTRODUCTION. Mobile bearing unicompartmental knee replacement (UKR) is an accepted treatment for patients with isolated medial unicompartmental knee osteoarthritis (OA) with a full thickness cartilage loss. The aim of this study was to determine if this recommendation was correct and if the procedure could be used for partial-thickness cartilage loss. METHODS. 1053 Oxford medial UKRs were studied prospectively. The knees were divided into two groups; partial-thickness cartilage loss (PTCL) group and the full thickness-cartilage loss (FTCL) group. The primary outcome measure was the total Oxford Knee Score (OKS, 0 to 48) at the time of final follow up. The groups were also compared for the change in OKS (?OKS) and the proportion of patients that were considered to have benefited substantially from surgery (?OKS >5). RESULTS. There were 21 knees in the PTCL group, with a mean age of 61 years (SD 13) and mean follow-up of 1.7 years (SD 1.0). There were 1032 knees in the FTCL group, with a mean age of 66 years (SD 10) and mean follow-up of 3.9 years (SD 2.5). The PTCL group had a significantly lower (p=0.03) total OKS (mean 35.8, SD 10.7) at final review than the FTCL group (mean 39.8, SD 8.5). There was no significant difference in pre-operative or ?OKS between the groups. However the proportion of patients that did not have substantial benefit from surgery (?OKS>5) was significant lower (p=0.04) in the PTCL group. CONCLUSIONS. The results confirm that a good outcome can routinely be achieved with UKR if there is bone-on-bone. If there is partial loss of cartilage the results are less predictable. Although some patients do well, a higher proportion do not benefit from the surgery. It may be that in a subgroup of these patients the pain did not initially arise from the partially damaged cartilage. We therefore recommend that the Oxford Knee should only be used for medial OA if there is bone on bone


The Bone & Joint Journal
Vol. 97-B, Issue 12 | Pages 1634 - 1639
1 Dec 2015
Faschingbauer M Renner L Waldstein W Boettner F

We studied whether the presence of lateral osteophytes on plain radiographs was a predictor for the quality of cartilage in the lateral compartment of patients with varus osteoarthritic of the knee (Kellgren and Lawrence grade 2 to 3).

The baseline MRIs of 344 patients from the Osteoarthritis Initiative (OAI) who had varus osteoarthritis (OA) of the knee on hip-knee-ankle radiographs were reviewed. Patients were categorised using the Osteoarthritis Research Society International (OARSI) osteophyte grading system into 174 patients with grade 0 (no osteophytes), 128 grade 1 (mild osteophytes), 28 grade 2 (moderate osteophytes) and 14 grade 3 (severe osteophytes) in the lateral compartment (tibia). All patients had Kellgren and Lawrence grade 2 or 3 arthritis of the medial compartment. The thickness and volume of the lateral cartilage and the percentage of full-thickness cartilage defects in the lateral compartment was analysed.

There was no difference in the cartilage thickness or cartilage volume between knees with osteophyte grades 0 to 3. The percentage of full-thickness cartilage defects on the tibial side increased from < 2% for grade 0 and 1 to 10% for grade 3.

The lateral compartment cartilage volume and thickness is not influenced by the presence of lateral compartment osteophytes in patients with varus OA of the knee. Large lateral compartment osteophytes (grade 3) increase the likelihood of full-thickness cartilage defects in the lateral compartment.

Cite this article: Bone Joint J 2015;97-B:1634–9.


The Journal of Bone & Joint Surgery British Volume
Vol. 83-B, Issue 4 | Pages 513 - 516
1 May 2001
Hoser C Fink C Brown C Reichkendler M Hackl W Bartlett J

We evaluated the outcome of partial lateral meniscectomy of 31 knees in 29 patients whose knees were otherwise normal. The mean follow-up was 10.3 years.

According to the Lysholm score, 14 knees were rated as excellent, four as good, five as fair and eight as poor, with a mean score of 80.5 points. Radiologically, only one lateral compartment was classified as grade 0, eight as grade 1, nine as grade 2, 11 as grade 3, and two as grade 4 according to Tapper and Hoover. No significant (p < 0.05) correlation was found between the amount of tissue resected and the subjective, clinical and radiological outcome.

Although early results of lateral meniscectomy may be satisfactory, we have demonstrated that in the long term there was a high incidence of degenerative changes, a high rate of reoperation (29%) and a relatively low functional outcome score.


Bone & Joint Research
Vol. 13, Issue 7 | Pages 342 - 352
9 Jul 2024
Cheng J Jhan S Chen P Hsu S Wang C Moya D Wu Y Huang C Chou W Wu K

Aims. To explore the efficacy of extracorporeal shockwave therapy (ESWT) in the treatment of osteochondral defect (OCD), and its effects on the levels of transforming growth factor (TGF)-β, bone morphogenetic protein (BMP)-2, -3, -4, -5, and -7 in terms of cartilage and bone regeneration. Methods. The OCD lesion was created on the trochlear groove of left articular cartilage of femur per rat (40 rats in total). The experimental groups were Sham, OCD, and ESWT (0.25 mJ/mm. 2. , 800 impulses, 4 Hz). The animals were euthanized at 2, 4, 8, and 12 weeks post-treatment, and histopathological analysis, micro-CT scanning, and immunohistochemical staining were performed for the specimens. Results. In the histopathological analysis, the macro-morphological grading scale showed a significant increase, while the histological score and cartilage repair scale of ESWT exhibited a significant decrease compared to OCD at the 8- and 12-week timepoints. At the 12-week follow-up, ESWT exhibited a significant improvement in the volume of damaged bone compared to OCD. Furthermore, immunohistochemistry analysis revealed a significant decrease in type I collagen and a significant increase in type II collagen within the newly formed hyaline cartilage following ESWT, compared to OCD. Finally, SRY-box transcription factor 9 (SOX9), aggrecan, and TGF-β, BMP-2, -3, -4, -5, and -7 were significantly higher in ESWT than in OCD at 12 weeks. Conclusion. ESWT promoted the effect of TGF-β/BMPs, thereby modulating the production of extracellular matrix proteins and transcription factor involved in the regeneration of articular cartilage and subchondral bone in an OCD rat model. Cite this article: Bone Joint Res 2024;13(7):342–352


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_7 | Pages 67 - 67
1 Jul 2022
Bhamber N Chaudhary A Middleton S Walmsley K Nelson A Powell R Mandalia V
Full Access

Abstract. Introduction. High posterior tibial slope (PTS) has been recognised as a risk factor for anterior cruciate ligament rupture and graft failure. This prospective randomised study looked at intra-operative findings of concomitant intra-articular meniscal and chondral injuries during a planned ACL reconstruction. Material and Methods. Prospective data was collected as part of a randomised trial for ACL reconstruction techniques. Intra-operative data was collected and these findings were compared with the PTS measured on plain radiograph by a single person twice through a standardised technique and intra-observer analysis was performed. Results. 49 confirmed ACL rupture patients were in the trial. The average age was 34 (23–66) years and 12 patients were female. 17 patients (34%) had PTS of 12 degrees or more. The intra-observer analysis for PTS measurements in a 2-sided paired T test, showed a mean difference of 0.03 degrees with a P value = 0.83. 23 patients had medial meniscal pathology identified, 15 (65%) had a PTS <12 degrees. 16 patients had lateral meniscus pathology and 9 (56%) had a PTS <12 degrees. Chondral damage did not appear significantly different in the two groups (<12 degrees 15% vs >12 degrees 23%). Conclusion. In this sample, a PTS >12 degrees was not associated with a higher incidence of meniscal or chondral damage after a confirmed ACL rupture


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_7 | Pages 17 - 17
1 Jul 2022
Naskar R Poletti F O'Leary S
Full Access

Abstract. Introduction. The outcome of revision anterior cruciate ligament reconstruction (ACL-R) is guarded, particularly their return to sports activities. It is important to know the factors affecting the functional outcomes following a revision ACL-R. Methods. We analysed results from 39 patients, who underwent a revision ACL reconstruction by a single surgeon and was followed up over a year. Some of them were treated in 2-stage revision while the rest were single-stage revision, depending upon their size of bone tunnel or osteolysis as assessed by pre-operative CT scan. Result. We analysed data from 39 patients with a mean age of 31 (17–52) and an average follow-up of 3.6 years (2–5 years). The average KOOS quality of life score was 58.94 (±23.02) and the mean Lysholm score was 89.48 (±10.1). Medial meniscal tear was significantly correlated with Lysholm score (p<0.005), but not with KOOS-QOL. Tear in lateral meniscus was not related significantly. Patients having Grade II or above cartilage damage showed inferior outcomes in terms of Lysholm score and poor return to sports, and it was statistically significant (p<0.02). There was no significant differences in outcomes between single stage revision and 2-stage revision (p=0.336). 15 patients (42.5%) returned to their pre-injury sports activities after revision surgery with the mean return to sports score of 58.65 (±16.1). Conclusions. The long-term functional outcome after revision ACL reconstruction is satisfactory, but not the return to sports. Expectations on outcome should be carefully managed particularly those having concomitant medial meniscal injury or cartilage damage


The Bone & Joint Journal
Vol. 103-B, Issue 6 Supple A | Pages 94 - 101
1 Jun 2021
Roy ME Whiteside LA Ly KK Gauvain MJ

Aims. The aims of this study were to evaluate wear on the surface of cobalt-chromium (CoCr) femoral components used in total knee arthroplasty (TKA) and compare the wear of these components with that of ceramic femoral components. Methods. Optical profilometry was used to evaluate surface roughness and to examine the features created by the wear process in a knee wear simulator. We developed a method of measuring surface changes on five CoCr femoral components and quantifying the loss of material from the articular surface during the wear process. We also examined the articular surface of three ceramic femoral components from a previous test for evidence of surface damage, and compared it with that of CoCr components. Results. We found that the surface roughness of CoCr components rapidly increased during the first 1,000 wear cycles, then reached a steady state, but material loss from the surface continued at a rate of 1,778,000 μm. 3. per million cycles as carbides were removed from its matrix. These carbides formed third-body wear particles, leading to the formation of new scratches even as older scratches were worn away. In contrast, no scratching, loss of material, or other surface damage, when evaluated with one nanometer resolution, was found on the surface of the ceramic components after a 15 M wear cycle test. Conclusion. This study showed wear and loss of CoCr material from scratching and microabrasive wear in TKA. The material loss from the surface continued in a linear relationship with increasing cycles. We also found the absence of scratching and roughening of ceramic femoral components in simulated wear, suggesting an advantage in wear rate and avoiding metal sensitivity. This may have implications in the management of persistent pain after TKA. Cite this article: Bone Joint J 2021;103-B(6 Supple A):94–101


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_13 | Pages 1 - 1
7 Aug 2023
Scheepers W Held M von Bormann R Wascher D Richter D Schenck R Harner C
Full Access

Abstract. Introduction. Knee dislocations (KDs) are complex injuries which are often associated with damage to surrounding soft tissues or neurovascular structures. A classification system for these injuries should be simple and reproducible and allow communication among surgeons for surgical planning and outcome prediction. The aim of this study was to formulate a list of factors, prioritised by high-volume knee surgeons, that should be included in a KD classification system. Methods. A global panel of orthopaedic knee surgery specialists participated in a Delphi process. A list of factors to be included in a KD classification system was formulated by 91 orthopaedic surgeons, which was subsequently prioritised by 27 experts from 6 countries. The items were analysed to find factors that had at least 70% consensus for inclusion in a classification system. Results. The four factors that reached consensus agreement and thus deemed critical for inclusion in a classification system were vascular injuries (89%), common peroneal nerve injuries (78%), number of torn ligaments (78%), and open injuries (70%). Conclusion. The wide geographic distribution of participants provides diverse insight and makes the results of the study globally applicable. The most important factors to include in a classification system as determined by the Delphi technique were vascular injuries, common peroneal nerve injuries, number of torn ligaments, and open injuries. The Schenck anatomic classification system most accurately identifies these patient variables with the addition of open injuries. The authors propose to update the Schenck classification system with the inclusion of open injuries as an additional modifier


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_13 | Pages 73 - 73
7 Aug 2023
Shatrov J Jones M Ball S Williams A
Full Access

Abstract. Introduction. The aim of this study was to determine the factors affecting return to sport (RTS) and career longevity of elite athletes after microfracture of the knee. Methods. A retrospective review of a consecutive series of elite athletes with chondral injuries in the knee treated with microfracture was undertaken. RTS was defined as competing in at least one event at professional level or national/ international level in amateur sport. Demographic, pre, intra and post operative factors affecting RTS were analysed. Results. Fifty six athletes, including 35 (62.5%) footballers and 14 (25.0 %) rugby players, with a mean age 24.8 (+/− 3.9) years, were included. 18 (32.1 %) of chondral injuries were secondary to trauma, 20 (35.7 %) post meniscectomy, 9 (16.1%) post anterior cruciate ligament (ACL) reconstruction and 9 (16.1%) idiopathic. Fifty (89.3%) of athletes RTS at a mean time of 10.0 (+/−5.8) months. 43 (86.0%) athletes were still playing at 2 years. At 5 years 25 (59.5%) of the players who had RTS and had surgery more than 5 years ago were still playing professional sport. Factors associated with not playing at 5 years were cartilage lesions >1.5cm2(52.4% vs 66.7%), more than 1 lesion (35.7% vs74.1%), lateral meniscal surgery (42.1% vs 73.7%) and effusion on RTS (47.7% vs 72.2%). Conclusion. Over 89 % of elite athletes returned to professional sport after microfracture in the knee. However, the ability to continue playing is affected by several factors such as the extent of the chondral damage and recurrent effusions


Bone & Joint Research
Vol. 8, Issue 10 | Pages 495 - 501
1 Oct 2019
Hampp EL Sodhi N Scholl L Deren ME Yenna Z Westrich G Mont MA

Objectives. The use of the haptically bounded saw blades in robotic-assisted total knee arthroplasty (RTKA) can potentially help to limit surrounding soft-tissue injuries. However, there are limited data characterizing these injuries for cruciate-retaining (CR) TKA with the use of this technique. The objective of this cadaver study was to compare the extent of soft-tissue damage sustained through a robotic-assisted, haptically guided TKA (RATKA) versus a manual TKA (MTKA) approach. Methods. A total of 12 fresh-frozen pelvis-to-toe cadaver specimens were included. Four surgeons each prepared three RATKA and three MTKA specimens for cruciate-retaining TKAs. A RATKA was performed on one knee and a MTKA on the other. Postoperatively, two additional surgeons assessed and graded damage to 14 key anatomical structures in a blinded manner. Kruskal–Wallis hypothesis tests were performed to assess statistical differences in soft-tissue damage between RATKA and MTKA cases. Results. Significantly less damage occurred to the PCLs in the RATKA versus the MTKA specimens (p < 0.001). RATKA specimens had non-significantly less damage to the deep medial collateral ligaments (p = 0.149), iliotibial bands (p = 0.580), poplitei (p = 0.248), and patellar ligaments (p = 0.317). The remaining anatomical structures had minimal soft-tissue damage in all MTKA and RATKA specimens. Conclusion. The results of this study indicate that less soft-tissue damage may occur when utilizing RATKA compared with MTKA. These findings are likely due to the enhanced preoperative planning with the robotic software, the real-time intraoperative feedback, and the haptically bounded saw blade, all of which may help protect the surrounding soft tissues and ligaments. Cite this article: Bone Joint Res 2019;8:495–501


The Bone & Joint Journal
Vol. 100-B, Issue 10 | Pages 1330 - 1335
1 Oct 2018
Ponzio DY Weitzler L deMeireles A Esposito CI Wright TM Padgett DE

Aims. The aim of this study was to evaluate the surface damage, the density of crosslinking, and oxidation in retrieved antioxidant-stabilized highly crosslinked polyethylene (A-XLPE) tibial inserts from total knee arthroplasty (TKA), and to compare the results with a matched cohort of standard remelted highly crosslinked polyethylene (XLPE) inserts. Materials and Methods. A total of 19 A-XLPE tibial inserts were retrieved during revision TKA and matched to 18 retrieved XLPE inserts according to the demographics of the patients, with a mean length of implantation of 15 months (1 to 42). The percentage areas of PE damage on the articular surfaces and the modes of damage were measured. The density of crosslinking of the PE and oxidation were measured at loaded and unloaded regions on these surfaces. Results. A-XLPE inserts had higher rates of burnishing and lower rates of pitting and scratching compared with XLPE. There were no differences in the density of crosslinking at loaded and unloaded regions. A-XLPE showed higher oxidation indices in the unloaded surface region compared with XLPE. There were no differences in the levels of oxidation in the loaded regions. Conclusion. Retrieval analysis of A-XLPE did not reflect a clinically relevant difference in surface damage, density of crosslinking, or oxidation compared with XLPE tibial inserts at short-term evaluation. Cite this article: Bone Joint J 2018;100-B:1330–5


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_11 | Pages 49 - 49
1 Oct 2019
Noble PC
Full Access

Introduction. The association between CoCr joint replacements and adverse tissue reactions has led to increased interest in alternative materials that are both biocompatible and wear-resistant. One approach is to manufacture components from titanium alloys with a hardened articulating surface to increase resistance to scratching and surface damage caused by third-body particles. In this study we investigate methods for characterizing the performance of retrieved TiAlV components with nitrogen-hardened bearing surfaces. Methods. Surface-hardened titanium knee implants (TiNidium) were retrieved from 18 patients (7.7 ±6.8 years) at revision surgery. After processing, the bearing surface of each component was characterized by stereomicroscopy, SEM, optical profilometry, and incremental nano-indentation hardness testing. A case-matched set of 18 CoCr components (6.7 ±5.6 years) were characterized for comparison. Results. Each bearing surface was graded for microscopic damage classified as pitting, abrasion, scratching, and burnishing using an Injury Severity Score. The components were divided into slight, average, and severe damage groups based on the resulting ISS scores. Representative specimens from each group were then subjected to SEM imaging, 12 roughness measurements, and 3 incremental nano-indentation hardness tests. Conclusion. There was no difference between the severity of surface damage of the hardened and CoCr components ((p=0.67); Table 1). The rate of surface damage was greatest in the first 2 years then decreased exponentially (Figure 1). Surface roughness (Ra) values were similar for both groups (TiAlV: 0.771um; CoCr: 0.884um) but decreased with the severity of visual damage in the TiNidium implants due to secondary burnishing of scratches. The hardness of the TiNidium implants varied with depth below the bearing surface in contrast to the CoCr controls in which hardness did not vary with depth (Figure 2). Our findings show that multiple complementary methods of are needed to adequately characterize the performance of surface hardened implants. For figures, tables, or references, please contact authors directly


Bone & Joint Research
Vol. 9, Issue 6 | Pages 322 - 332
1 Jun 2020
Zhao H Yeersheng R Kang X Xia Y Kang P Wang W

Aims. The aim of this study was to examine whether tourniquet use can improve perioperative blood loss, early function recovery, and pain after primary total knee arthroplasty (TKA) in the setting of multiple-dose intravenous tranexamic acid. Methods. This was a prospective, randomized clinical trial including 180 patients undergoing TKA with multiple doses of intravenous tranexamic acid. One group was treated with a tourniquet during the entire procedure, the second group received a tourniquet during cementing, and the third group did not receive a tourniquet. All patients received the same protocol of intravenous tranexamic acid (20 mg/kg) before skin incision, and three and six hours later (10 mg/kg). The primary outcome measure was perioperative blood loss. Secondary outcome measures were creatine kinase (CK), CRP, interleukin-6 (IL-6), visual analogue scale (VAS) pain score, limb swelling ratio, quadriceps strength, straight leg raising, range of motion (ROM), American Knee Society Score (KSS), and adverse events. Results. The mean total blood loss was lowest in the no-tourniquet group at 867.32 ml (SD 201.11), increased in the limited-tourniquet group at 1024.35 ml (SD 176.35), and was highest in the tourniquet group at 1,213.00 ml (SD 211.48). The hidden blood loss was lowest in the no-tourniquet group (both p < 0.001). There was less mean intraoperative blood loss in the tourniquet group (77.48 ml (SD 24.82)) than in the limited-tourniquet group (137.04 ml (SD 26.96)) and the no-tourniquet group (212.99 ml (SD 56.35); both p < 0.001). Patients in the tourniquet group showed significantly higher levels of muscle damage and inflammation biomarkers such as CK, CRP, and IL-6 than the other two groups (p < 0.05). Outcomes for VAS pain scores, limb swelling ratio, quadriceps strength, straight leg raising, ROM, and KSS were significantly better in the no-tourniquet group at three weeks postoperatively (p < 0.05), but there were no significant differences at three months. No significant differences were observed among the three groups with respect to transfusion rate, thrombotic events, or the length of hospital stay. Conclusion. Patients who underwent TKA with multiple doses of intravenous tranexamic acid but without a tourniquet presented lower total blood loss and hidden blood loss, and they showed less postoperative inflammation reaction, less muscle damage, lower VAS pain score, and better early knee function. Our results argue for not using a tourniquet during TKA. Cite this article: Bone Joint Res 2020;9(6):322–332


The Bone & Joint Journal
Vol. 99-B, Issue 5 | Pages 632 - 639
1 May 2017
Hamilton TW Pandit HG Maurer DG Ostlere SJ Jenkins C Mellon SJ Dodd CAF Murray DW

Aims. It is not clear whether anterior knee pain and osteoarthritis (OA) of the patellofemoral joint (PFJ) are contraindications to medial unicompartmental knee arthroplasty (UKA). Our aim was to investigate the long-term outcome of a consecutive series of patients, some of whom had anterior knee pain and PFJ OA managed with UKA. Patients and Methods. We assessed the ten-year functional outcomes and 15-year implant survival of 805 knees (677 patients) following medial mobile-bearing UKA. The intra-operative status of the PFJ was documented and, with the exception of bone loss with grooving to the lateral side, neither the clinical or radiological state of the PFJ nor the presence of anterior knee pain were considered a contraindication. The impact of radiographic findings and anterior knee pain was studied in a subgroup of 100 knees (91 patients). Results. There was no relationship between functional outcomes, at a mean of ten years, or 15-year implant survival, and pre-operative anterior knee pain, or the presence or degree of cartilage loss documented intra-operatively at the medial patella or trochlea, or radiographic evidence of OA in the medial side of the PFJ. In 6% of cases there was full thickness cartilage loss on the lateral side of the patella. In these cases, the overall ten-year function and 15-year survival was similar to those without cartilage loss; however they had slightly more difficulty with descending stairs. Radiographic signs of OA seen in the lateral part of the PFJ were not associated with a definite compromise in functional outcome or implant survival. Conclusion. Severe damage to the lateral side of the PFJ with bone loss and grooving remains a contraindication to mobile-bearing UKA. Less severe damage to the lateral side of the PFJ and damage to the medial side, however severe, does not compromise the overall function or survival, so should not be considered to be a contraindication. However, if a patient does have full thickness cartilage loss on the lateral side of the PFJ they may have a slight compromise in their ability to descend stairs. Pre-operative anterior knee pain also does not compromise the functional outcome or survival and should not be considered to be a contraindication. Cite this article: Bone Joint J 2017;99-B:632–9


The Bone & Joint Journal
Vol. 100-B, Issue 3 | Pages 285 - 293
1 Mar 2018
Nakamae A Adachi N Deie M Ishikawa M Nakasa T Ikuta Y Ochi M

Aims. To investigate the risk factors for progression of articular cartilage damage after anatomical anterior cruciate ligament (ACL) reconstruction. Patients and Methods. A total of 174 patients who underwent second-look arthroscopic evaluation after anatomical ACL reconstruction were enrolled in this study. The graded condition of the articular cartilage at the time of ACL reconstruction was compared with that at second-look arthroscopy. Age, gender, body mass index (BMI), ACL reconstruction technique, meniscal conditions, and other variables were assessed by regression analysis as risk factors for progression of damage to the articular cartilage. Results. In the medial compartment, multivariable logistic regression analysis indicated that partial medial meniscectomy (odds ratio (OR) 6.82, 95% confidence interval (CI) 2.11 to 22.04, p = 0.001), pivot-shift test grade at the final follow-up (OR 3.53, CI 1.39 to 8.96, p = 0.008), BMI (OR 1.15, CI 1.03 to 1.28, p = 0.015) and medial meniscal repair (OR 3.19, CI 1.24 to 8.21, p = 0.016) were significant risk factors for progression of cartilage damage. In the lateral compartment, partial lateral meniscectomy (OR 10.94, CI 4.14 to 28.92, p < 0.001) and side-to-side differences in anterior knee laxity at follow-up (OR 0.63, p = 0.001) were significant risk factors. Conclusion. Partial meniscectomy was found to be strongly associated with the progression of articular cartilage damage despite r anatomical ACL reconstruction. Cite this article: Bone Joint J 2018;100-B:285–93


Bone & Joint Research
Vol. 12, Issue 1 | Pages 58 - 71
17 Jan 2023
Dagneaux L Limberg AK Owen AR Bettencourt JW Dudakovic A Bayram B Gades NM Sanchez-Sotelo J Berry DJ van Wijnen A Morrey ME Abdel MP

Aims

As has been shown in larger animal models, knee immobilization can lead to arthrofibrotic phenotypes. Our study included 168 C57BL/6J female mice, with 24 serving as controls, and 144 undergoing a knee procedure to induce a contracture without osteoarthritis (OA).

Methods

Experimental knees were immobilized for either four weeks (72 mice) or eight weeks (72 mice), followed by a remobilization period of zero weeks (24 mice), two weeks (24 mice), or four weeks (24 mice) after suture removal. Half of the experimental knees also received an intra-articular injury. Biomechanical data were collected to measure passive extension angle (PEA). Histological data measuring area and thickness of posterior and anterior knee capsules were collected from knee sections.