Advertisement for orthosearch.org.uk
Results 1 - 17 of 17
Results per page:
Bone & Joint Research
Vol. 7, Issue 1 | Pages 36 - 45
1 Jan 2018
Kleinlugtenbelt YV Krol RG Bhandari M Goslings JC Poolman RW Scholtes VAB

Objectives. The patient-rated wrist evaluation (PRWE) and the Disabilities of the Arm, Shoulder and Hand (DASH) questionnaire are patient-reported outcome measures (PROMs) used for clinical and research purposes. Methodological high-quality clinimetric studies that determine the measurement properties of these PROMs when used in patients with a distal radial fracture are lacking. This study aimed to validate the PRWE and DASH in Dutch patients with a displaced distal radial fracture (DRF). Methods. The intraclass correlation coefficient (ICC) was used for test-retest reliability, between PROMs completed twice with a two-week interval at six to eight months after DRF. Internal consistency was determined using Cronbach’s α for the dimensions found in the factor analysis. The measurement error was expressed by the smallest detectable change (SDC). A semi-structured interview was conducted between eight and 12 weeks after DRF to assess the content validity. Results. A total of 119 patients (mean age 58 years (. sd. 15)), 74% female, completed PROMs at a mean time of six months (. sd. 1) post-fracture. One overall meaningful dimension was found for the PRWE and the DASH. Internal consistency was excellent for both PROMs (Cronbach’s α 0.96 (PRWE) and 0.97 (DASH)). Test-retest reliability was good for the PRWE (ICC 0.87) and excellent for the DASH (ICC 0.91). The SDC was 20 for the PRWE and 14 for the DASH. No floor or ceiling effects were found. The content validity was good for both questionnaires. Conclusion. The PRWE and DASH are valid and reliable PROMs in assessing function and disability in Dutch patients with a displaced DRF. However, due to the high SDC, the PRWE and DASH are less useful for individual patients with a distal radial fracture in clinical practice. Cite this article: Y. V. Kleinlugtenbelt, R. G. Krol, M. Bhandari, J. C. Goslings, R. W. Poolman, V. A. B. Scholtes. Are the patient-rated wrist evaluation (PRWE) and the disabilities of the arm, shoulder and hand (DASH) questionnaire used in distal radial fractures truly valid and reliable? Bone Joint Res 2018;7:36–45. DOI: 10.1302/2046-3758.71.BJR-2017-0081.R1


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_9 | Pages 90 - 90
17 Apr 2023
Kale S Singh S Dhar S
Full Access

To evaluate the functional outcome of open humerus diaphyseal fractures treated with the Three-stitch technique of antegrade humerus nailing. This is a retrospective study conducted at the Department of Orthopaedics in D. Y. Patil University, School of Medicine, Navi Mumbai, India. The study included 25 patients who were operated on from January 2019 to April 2021 and follow-ups done till May 2022. Inclusion criteria were adult patients with open humerus diaphyseal fractures (Gustilo-Anderson Classification). All patients with closed fractures, skeletally immature patients, and patients with associated head injury were excluded from the study. All patients were operated on with a minimally invasive Three-stitch technique for antegrade humerus nailing. All patients were evaluated based on DASH score. Out of the 25 patients included in the study, all patients showed complete union. The mean age of the patients was 40.4 years (range 23–66 years). The average period for consolidation of fracture was 10.56 weeks (range 8–14 weeks). The DASH score ranged from 0 to 15.8 with an average score of 2.96. Five patients reported complications with three patients of post-operative infection and delayed wound healing and two patients with screw loosening. All complications were resolved with proper wound care and the complete union was noted. None of the patients had an iatrogenic neurovascular injury. Three-stitch antegrade nailing technique is a novel method to treat diaphyseal humerus fractures and provides excellent results. It has various advantages such as minimal invasiveness, minimal injury to the rotator cuff, fewer infection rates, minimal iatrogenic injuries, and good functional outcomes. Therefore, this treatment modality can be effectively used for open humerus diaphyseal fractures


To analyse the efficacy and safety of cellular therapy utilizing Mesenchymal Stromal Cells (MSCs) in the management of rotator cuff(RC) tears from clinical studies available in the literature. We conducted independent and duplicate electronic database searches including PubMed, Embase, Web of Science, and Cochrane Library on August 2021 for studies analyzing the efficacy and safety of cellular therapy (CT) utilizing MSCs in the management of RC tears. VAS for pain, ASES Score, DASH Score, Constant Score, radiological assessment of healing and complications and adverse events were the outcomes analyzed. Analysis was performed in R-platform using OpenMeta [Analyst] software. RESULTS:. 6 studies involving 238 patients were included for analysis. We noted a significant reduction in VAS score for pain at 3 months (WMD=-2.234,p<0.001) and 6 months (WMD=-3.078,p<0.001) with the use of CT. Concerning functional outcomes, utilization of CT produced a significant short-term improvement in the ASES score (WMD=17.090,p<0.001) and significant benefit in functional scores such as Constant score (WMD=0.833,p=0.760) at long-term. Moreover, we also observed a significantly improved radiological tendon healing during the long-term follow-up (OR=3.252,p=0.059). We also noted a significant reduction in the retear rate upon utilization of CT in RC tears both at short- (OR=0.079,p=0.032) and long-term (OR=0.434,p=0.027). We did not observe any significant increase in the adverse events as compared with the control group (OR=0.876,p=0.869). Utilization of CT in RC tear is safe and it significantly reduced pain severity, improved functional outcome, enhanced radiological tendon healing, and mitigated retear rates at short- and long-term follow-up


Introduction. This study aims to investigate the relationship between ulnar fixation and postoperative satisfaction among patients with distal radius fractures accompanied by ulna styloid fractures, with a particular focus on how sociodemographic factors influence outcomes. Method. A retrospective cohort study was conducted involving 120 patients aged 26-53 who underwent surgical treatment for distal radius fractures with concomitant ulna styloid fractures between January 2018 and December 2022. Patients were divided into two groups based on whether ulnar fixation was performed. Sociodemographic data, including age, gender, socioeconomic status, education level, and occupation, were collected. All patients underwent similar physical therapy protocols in the postoperative period, and no complications were observed in any patient. Postoperative satisfaction was assessed using the Patient-Rated Wrist Evaluation (PRWE) and the Disabilities of the Arm, Shoulder, and Hand (DASH) scores at 6 and 12 months post-surgery. Statistical analysis was conducted to evaluate the influence of ulnar fixation and sociodemographic factors on patient satisfaction. Result. Patients who underwent ulnar fixation (n=60) reported significantly higher satisfaction levels compared to those who did not (n=60), as evidenced by lower PRWE and DASH scores (p < 0.05). Age, gender, and socioeconomic status were significant predictors of postoperative satisfaction. Younger patients, females, and those with higher socioeconomic status exhibited greater improvements in functional outcomes and satisfaction. However, education level and occupation did not significantly influence satisfaction scores. Conclusion. Ulnar fixation in the surgical treatment of distal radius fractures accompanied by ulna styloid fractures is associated with improved postoperative satisfaction. Sociodemographic factors, particularly age, gender, and socioeconomic status, play a crucial role in patient-reported outcomes. Tailoring postoperative care to address these sociodemographic differences may enhance overall patient satisfaction and recovery


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_7 | Pages 57 - 57
4 Apr 2023
Tariq M Uddin Q Amin H Ahmed B
Full Access

This study aims to compare the outcomes of Volar locking plating (VLP) versus percutaneous Kirschner wires (K-wire) fixation for surgical management of distal radius fractures. We systematically searched multiple databases, including MEDLINE for randomized controlled trials (RCTs) comparing outcomes of VLP fixation and K-wire for treatment of distal radius fracture in adults. The methodological quality of each study was assessed by the Cochrane Risk of Bias tool. Patient-reported outcomes, functional outcomes, and complications at 1 year follow up were evaluated. Meta-analysis was performed using random-effects models and results presented as risk ratios (RRs) or mean differences (MDs) with 95% confidence interval (CI). 13 RCTs with 1336 participants met the inclusion criteria. Disabilities of the Arm, Shoulder and Hand (DASH) scores were significantly better for VLP fixation (MD= 2.15; 95% CI, 0.56-3.74; P = 0.01; I2=23%). No significant difference between the two procedures for grip strength measured in kilograms (MD= −3.84; 95% CI,-8.42-0.74; P = 0.10; I2=52%) and Patient-Rated Wrist Evaluation (PRWE) scores (MD= −0.06; 95% CI,-0.87-0.75; P = 0.89; I2=0%). K-wire treatment yielded significantly improved extension (MD= −4.30; P=0.04) but with no differences in flexion, pronation, supination, and radial deviation (P >0.05). The risk of complications and rate of reoperation were similar for the two procedures (P >0.05). This meta-analysis suggests that VLP fixation improves DASH score at 12 months follow up, however, the difference is small and unlikely to be clinically important. Existing literature does not provide sufficient evidence to demonstrate the superiority of either VLP or K-wire treatment in terms of patient-reported outcomes, functional outcomes, and complications


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_14 | Pages 11 - 11
1 Dec 2022
Bergomi A Adriani M De Filippo F Manni F Motta M Saccomanno M Milano G
Full Access

Rotator cuff repair has excellent clinical outcomes but continues to be a challenge when it comes to large and massive tears as well as revision procedures. Reported symptomatic retear rates are still too high to be acceptable. The purpose of the present study was to evaluate the effectiveness of a combination of augmentation techniques consisting of microfractures of the greater tuberosity, extracellular matrix (ECM) patch graft and subsequent platelet concentrate (PC) subacromial injections in revision rotator cuff repair. The study was designed as a retrospective comparative study on prospectively collected data from a consecutive cohort of patients. All patients who underwent arthroscopic revision rotator cuff repair for symptomatic failure of previous posterosuperior rotator cuff repair were considered eligible for the study. Symptomatic failure had been diagnosed according to clinical examination and confirmed by magnetic resonance imaging (MRI). Structural integrity had been assessed on MRI and classified according to Sugaya classification. Only patients affected by stage IV-V were considered eligible. Tear reparability was confirmed during arthroscopy. Only patients with a minimum 2 years follow-up were included. Patients were divided in two groups. In group 1 (control group) a standard arthroscopic revision and microfractures of the greater tuberosity were performed; in group 2 (experimental group), microfractures of the greater tuberosity and a ECM patch graft were used to enhance tendon repair, followed by postoperative PC injections. Minimum follow-up was 12 months. Primary outcome was the Constant-Murley score (CMS) normalized for age and gender. Subjective outcome was assessed with the Disabilities of the Arm, Shoulder and Hand (DASH) score in its short version (Quick-DASH). Tendon integrity was assessed with MRI at 6 months after surgery. Comparison between groups for all discrete variables at baseline and at follow-up was carried out with the Student's t-test for normally distributed data, otherwise Mann-Whitney U-test was used. Within-group differences (baseline vs follow-up) for discrete variables were analyzed by paired t-test, or by Wilcoxon signed-rank test in case of data with non-normal distribution. Differences for categorical variables were assessed by chi-squared test. Significance was considered for p values < 0.05. Forty patients were included in the study (20 patients for each group). The mean follow-up was 13 ± 1.6 months. No patients were lost at the follow up. Comparison between groups did not show significant differences for baseline characteristics. At follow-up, mean CMS was 80.7 ± 16.6 points in group 1 and 91.5 ± 11.5 points in group 2 (p= 0.022). Mean DASH score was 28.6 ± 21.6 points in group 1 and 20.1 ± 17.4 points in group 2 (p= 0.178). Post-operative MRI showed 6 healed shoulders in Group 1 and 16 healed shoulders in Group 2 (p<0.004). No postoperative complications were reported in both groups. The combination of microfractures of the greater tuberosity, ECM patch graft, and subsequent PC subacromial injections is an effective strategy in improving tendon healing rate


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_13 | Pages 34 - 34
1 Nov 2021
Larsen JB Østergaard HK Thillemann TM Falstie-Jensen T Reimer L Noe S Jensen SL Mechlenburg I
Full Access

Introduction and Objective. Only few studies have investigated the outcome of exercises in patients with glenohumeral osteoarthritis (OA) or rotator cuff tear arthropathy (CTA), and furthermore often excluded patients with a severe degree of OA. Several studies including a Cochrane review have suggested the need for trials comparing shoulder arthroplasty to non-surgical treatments. Before initiation of such a trial, the feasibility of progressive shoulder exercises (PSE) in patients, who are eligible for shoulder arthroplasty should be investigated. The aim was to investigate whether 12 weeks of PSE is feasible in patients with OA or CTA eligible for shoulder arthroplasty. Moreover, to report changes in shoulder function and range of motion (ROM) following the exercise program. Materials and Methods. Eighteen patients (11 women, 14 OA), mean age 70 years (range 57–80), performed 12 weeks of PSE with 1 weekly physiotherapist-supervised and 2 weekly home-based sessions. Feasibility was measured by drop-out rate, adverse events, pain and adherence to PSE. Patients completed Western Ontario Osteoarthritis of the Shoulder (WOOS) score and Disabilities of the Arm, Shoulder and Hand (DASH). Results. Two patients dropped out and no adverse events were observed. Sixteen patients (89%) had high adherence to the physiotherapist-supervised sessions. Acceptable pain levels were reported. WOOS improved mean 23 points (95%CI:13;33), and DASH improved mean 13 points (95%CI:6;19). Conclusions. PSE is feasible, safe and may improve shoulder pain, function and ROM in patients with OA or CTA eligible for shoulder arthroplasty. PSE is a feasible treatment that may be compared with arthroplasty in a RCT setting


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_13 | Pages 119 - 119
1 Nov 2021
Facchini A Troiano E Saviori M Meglio MD Ghezzi R Mondanelli N Giannotti S
Full Access

Introduction and Objective. The aim of this study was to evaluate whether CT-based pre-operative planning, integrated with intra-operative navigation could improve glenoid baseplate fixation and positioning by increasing screw length, reducing number of screws required to obtain fixation and increasing the use of augmented baseplate to gain the desired positioning. Reverse total shoulder arthroplasty (RSA) successfully restores shoulder function in different conditions. Glenoid baseplate fixation and positioning seem to be the most important factors influencing RSA survival. When scapular anatomy is distorted (primitive or secondary), optimal baseplate positioning and secure screw purchase can be challenging. Materials and Methods. Twenty patients who underwent navigated RSA (oct 2018 and feb 2019) were compared retrospectively with twenty patients operated on with a conventional technique. All the procedures were performed by the same surgeon, using the same implant in cases of eccentric osteoarthritis or complete cuff tear. Exclusion criteria were: other diagnosis as proximal humeral fractures, post-traumatic OA previously treated operatively with hardware retention, revision shoulder arthroplasty. Results. The NAV procedure required mean 11 (range 7–16) minutes more to performed than the conventional procedure. Mean screw length was significantly longer in the navigation group (35.5+4.4 mm vs 29.9+3.6 mm; p . .001). Significant higher rate of optimal fixation using 2 screws only (17 vs 3 cases, p . .019) and higher rate of augmented baseplate usage (13 vs 4 cases, p . .009) was also present in the navigation group. Signficant difference there is all in function outcomes, DASH score is 15.7 vs 29.4 and constant scale 78.1 vs 69.8. Conclusions. The glenoid component positioning in RSA is crucial to prevent failure, loosening and biomechanical mismatch, coverage by the baseplate of the glenoid surface, version, inclination and offset are all essential for implant survival. This study showed how useful 3D CT-based planning helps in identifying the best position of the metaglena and the usefulness of receiving directly in the operation theater real-time feedback on the change in position. This study shows promising results, suggesting that improved baseplate and screw positioning and fixation is possible when computer-assisted implantation is used in RSA comparing to a conventional procedure


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_13 | Pages 60 - 60
1 Mar 2013
Bakhsh H Ibrahim I Khan W Smitham P Goddard N
Full Access

In recent years, there has been an increase in using self- admistrated questionnaires to accurately assess intervention outcomes in hand surgery to determine the quality of healthcare. This study aims to evaluate whether the Manchester Modified Disabilities of the Arm, Shoulder and Hand (M2DASH) questionnaire is a valid, reliable, responsive, and unbiased outcome measure for Carpal Tunnel syndrome compared to the Disability of Arm, Shoulder, and Hand (DASH) questionnaire, Boston questionnaire (BQ), and Nerve Conduction Studies (NCS). Method. 48 patients with CTS confirmed by NCS completed the M2DASH, original DASH, and the BQ, at least twice at different time intervals. The scores obtained from M2DASH were compared and correlated with the DASH, BQ, and NCS to assess validity, reliability, responsiveness, and bias of the questionnaires. Results. Validity analysis for M2DASH showed strong positive correlations with the Original DASH and BQ. No significant correlation was obtained from correlating with NCS. Reliability testing confirmed that the M2DASH is internally consistent and reproducible outcome. Significant results for responsiveness were noted in BQ symptom severity scale only. There was no age, gender, hand dominance, or side affected bias in all three questionnaires. Conclusions. The M2DASH is a valid, reliable, and unbiased outcome measure for CTS. In terms of responsiveness this study demonstrated that M2DASH & DASH is weak in detecting the clinical change for CTS, except for the BQ. Further assessment of responsiveness specifically for CTS is required in order to implement this questionnaire in clinical practice to accurately obtain results reflecting the patients progression


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_31 | Pages 12 - 12
1 Aug 2013
Elias-Jones C MacLeod C
Full Access

In 2012 collagenase Clostridium histolyticum (Xiapex) was approved by the SMC for restricted use for the treatment of Dupuytren's contracture. Xiapex was approved on a case by case basis for patients with a palpable pretendinous cord, giving rise to MCPJ contracture of greater than 30 degrees. As of September 2012 we began to offer Xiapex injections to patients in Ayrshire who enquired about the injection, and met the SMC criteria. To date injections have been performed on 3 patients, in a total of 7 digits. Patients were assessed prior to injection and manipulation, with the degree of contracture recorded and DASH scores noted. Each patient then underwent a standard injection of 0.58 mg of Xiapex. 48 hours post injection each patient underwent manipulation under local anaesthetic, with contractures remeasured, pain scored using a visual analogue scale and complications noted. Each patient was then reviewed at 4 weeks post injection where the residual degree of contracture was recorded and a further DASH score completed. Mean contracture at the MCPJ prior to injection was 57° (range 34–80), and mean DASH score of 20.8 (range 16.7–24.2). Following manipulation mean residual contracture at the MCPJ measured 21° (range 18–28). The average pain score following was manipulation was rated at 1.1. Mild bruising and swelling were reported in all cases following injection, and manipulation resulted in 2 minor skin tears. At the 4 week review prolonged improvement of contracture was achieved with a mean residual contracture of 14° (range −2–40); with a significant improvement in DASH scores – mean 0.6 (range 0–1.8). Despite small numbers, we have found Xiapex injections to be a successful and well tolerated treatment for moderate Dupuytren's disease. Further follow up is required to assess the longevity of the correction and ensure the cost effectiveness of Xiapex


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_4 | Pages 19 - 19
1 Apr 2018
Martens S Lipperts M Samijo S Walbeehm R Grimm B
Full Access

Background. Shoulder pain limits range of motion (ROM) and reduces performing activities of daily living (ADL). Objective assessment of shoulder function could be of interest for diagnosing shoulder pathology or functional assessment of the shoulder after therapy. The feasibility of 2 wearable inertial sensors for functional assessment to differentiate between healthy subjects and patients with unilateral shoulder pathology is investigated using parameters as asymmetry. Methods. 75 subjects were recruited into this study and were measured for at least 8 h a day with the human activity monitor (HAM) sensor. In addition, patients completed the Disability of the Arm, Should and Hand (DASH) score and the Simple Shoulder Test (SST) score. From 39 patients with a variety of shoulder pathologies 24 (Age: 53.3 ± 10.5;% male: 62.5%) complete datasets were successfully collected. From the 36 age-matched healthy controls 28 (Age: 54.9 ± 5.8;% male = 57.1%) full datasets could be retrieved. Activity parameters were obtained using a self-developed algorithm (Matlab). Outcome parameters were gyroscope and accelerometry-based relative and absolute asymmetry scores (affected/unaffected; dominant/non-dominant) of movement intensity. Results & Discussion. The absolute and relative asymmetry scores of the accelerometry-based intensity results for a threshold of > 0.1 g (AUC 0.821 and AUC 0.827) proved to be slightly more distinctive to the gyroscope-based intensity results for a threshold of > 10 deg/s (AUC 0.807 and 0.795) to distinguish between the healthy group and the shoulder group. Asymmetry (< 1%) was nearly absent in healthy controls (5/56 subjects) using the accelerometry-based intensity (> 0.1g) results but common in patients (29/48 subjects). A moderate, significant correlation was found between the asymmetry scores and the DASH score, thus complementary use is advised. The asymmetry scores had no correlation to the SST score. Conclusion. Ambulant assessment of shoulder activity using human activity monitors, containing a gyroscope and accelerometer, during ADL is feasible. The accelerometry-based and gyroscope-based absolute and relative asymmetry scores are promising parameters to diagnose or assess function of the shoulder. A moderate correlation was found between the DASH score and the activity monitor parameters, suggesting both could be used complementary to assess function


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_11 | Pages 351 - 351
1 Jul 2014
Ouellette E Yang S Morris J Makowski A Fung W
Full Access

Summary. Arthroscopic decompression of the lunate decreases clinical symptoms and slows progression of Kienböck's Disease. Introduction. The purpose of this study was to investigate the outcomes of patients suffering from avascular necrosis of the lunate, or Kienböck's Disease, who received arthroscopic decompression to treat the ischemic lunate. Previous studies have demonstrated an elevated intraosseus pressure in the ischemic lunate, and it has been hypothesised that ischemia in the lunate is secondary to this elevated pressure and subsequent venous congestion, as opposed to diminished arterial supply. Based on this work we have used decompression of the lunate to prevent progression of the disease. Patients and Methods. 21 patients, (22 wrists), reported to a single surgeon with a chief complaint of unremitting wrist pain and the subsequent diagnosis was Kienböck's disease, stages I, II, IIIA or IIIB. Range of motion measurement and grip strength, as well as self-reported outcome measures such as Disabilities of the Arm, Shoulder and Hand (DASH) and Modified Mayo, were obtained preoperatively and post operatively at 2, 7 and 12 months. The patients were treated operatively with arthroscopic decompression of the lunate. The lunate was approached dorsally at the interosseous lunotriquetral and the scapholunate ligament areas with an arthroscopic shaver until brisk bleeding was achieved upon deflating the tourniquet. In some cases, the core of the lunate had to be penetrated with a 45 k-wire until bleeding was obtained. Of the 22 wrists treated arthroscopically with lunate decompression, 18 had both pre-surgical and post-surgical follow-up evaluations. Results. The patients who underwent lunate arthroscopic decompression surgery demonstrated a statistically significant improvement in DASH score at 7 and 12 months postoperatively (p<0.05). The preoperative DASH score average for this cohort was 51, while post-operative DASH scores averaged 23 and 17 at 7 and 12 months, respectively. The patients also demonstrated some overall improvement in pain, functionality, range of motion, and grip strength as demonstrated by the Modified Mayo wrist score. Notably, the patients demonstrated statistically significant improvement in grip strength post-operatively at 7-months (p<0.05) and 12-months (p<0.01). In addition, there was noted to be improvement in supination and ulnar deviation measurements post-operatively at 7 months and 12 months, respectively. Conclusion. This study demonstrates the clinical outcome of arthroscopic decompression of the lunate in patients suffering from Kienböck's Disease using the patient's subjective evaluations as well as range of motion and grip strength measurements. Arthroscopic decompression of the lunate decreases clinical symptoms and slows progression of Kienböck's Disease using a less invasive surgical intervention


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXVIII | Pages 43 - 43
1 Jun 2012
McKenna R Winter A Leach W
Full Access

Distal radial fractures are amongst the most common trauma referrals, however controversy remains regarding their optimum management. We undertook a retrospective review of the management of distal radial fractures in our department. The prospectively maintained trauma database was used to identify patients admitted for operative management of a dorsally displaced distal radial fracture between June 2008 and June 2009. Only extra-articular or simple intra-articular fractures were included (AO classification A2/A3/C1/C2). Operation notes were reviewed to determine the method of fixation. Patients were contacted by post and asked to complete a functional outcome score - Disabilities of the Arm, Shoulder and Hand (DASH). A further 12 patients with similar fractures who had been managed conservatively were also asked to complete a DASH score to provide a comparison between operative and non-operative management. 98 patients were identified - 67 female, 31 male. Mean age was 51 years, range 15-85 years. All patients were at least 1 year post-op. 26 patients had manipulation under anaesthesia (MUA). 48 patients had MUA and K-wire fixation, which was supplemented with synthetic bone substitute in 16 cases. 3 patients had MUA and bone graft and 21 patients had open reduction and internal fixation (ORIF) with a volar plate. 34 correctly completed DASH scores were returned. A lower score equates to a better functional outcome. Mean DASH scores were: MUA 14.8; MUA+K-wire 13.1; ORIF 13.6; conservative 47.1. This data would indicate that patients with a significantly displaced distal radial fracture have a better functional outcome with operative management to improve the fracture alignment. However, all of the methods of fixation used resulted in similar functional outcomes at one year


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_31 | Pages 14 - 14
1 Aug 2013
Drury C Elias-Jones C Tait G
Full Access

Arthritis of the glenohumeral joint accompanied by an irreparable tear of the rotator cuff can cause severe pain, disability and loss of function, particularly in the elderly population. Anatomical shoulder arthroplasty requires a functioning rotator cuff, however, reverse shoulder arthroplasty is capable of addressing both rotator cuff disorders and glenohumeral deficiencies. The Aequalis Reversed Shoulder Prosthesis design is based on two bio-mechanical principles by Grammont; a medialized center of rotation located inside the glenoid bone surface and second, a 155 degree angle of inclination. Combined, they increase the deltoid lever arm by distalizing the humerus and make the prosthesis inherently stable. 24 consecutive primary reverse total shoulder arthroplasties were performed by a single surgeon for arthritis with rotator cuff compromise and 1 as a revision for a failed primary total shoulder replacement between December 2009 and October 2012. Patients were assessed postoperatively with the use of the DASH score, Oxford shoulder score, range of shoulder motion and plain radiography with Sirveaux score for scapular notching. Mean age at the time of surgery was 72.5 years (range 59 to 86). Average follow up time was 19.4 months (range 4 to 38). Functional outcome scores from our series were comparable with patients from other follow up studies of similar prosthesis design. All patients showed improvement in range of shoulder movement postoperatively. Complications included one dislocation, one acromion fracture and one humeral shaft fracture. No cases of deep infection were recorded. Overall, the short-term clinical results were promising for this series of patients and indicate reverse shoulder arthroplasty as an appropriate treatment for this group of patients


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_11 | Pages 274 - 274
1 Jul 2014
Hendriks G Senden R Heyligers I Meijer K Grimm B
Full Access

Summary. Upper extremity activity was similar in patients and healthy subjects, showing no significant asymmetry between arms within subjects. Further improvements (e.g. thresholds, filters, inclinometer function) are needed to show the clinical value of AM for patients suffering shoulder complaints. Introduction. Activity monitoring is becoming a popular outcome tool especially in orthopaedics. The suitability of a single 3D acceleration-based activity monitor (AM) for patients with lower-extremity problems has been shown. However less is known about its feasibility to monitor upper-extremity activity. Insight into the amount and intensity of upper-extremity activity of the affected and non-affected arm (asymmetry) may be of added value for diagnostics, therapy choice and evaluating treatment effects. This study investigates the feasibility of a single AM to evaluate (asymmetry in) upper-extremity activity in daily life. Methods. Upper-extremity activity was measured in 12 patients with subacromial impingent syndrome (59±12yr) and 10 healthy subjects (29±11yrs). Subjects wore a single 3D accelerometer at both arms, just above the base of the Hueter triangle, for one day (min. 8 hours). Specific algorithms were used to derive quantity (activity duration, rest periods) and intensity (low-high) activity parameters (% of the day). The ratio in % activity between non-affected (dominant) and affected (non-dominant) arm was calculated. Asymmetry was expressed as the %-difference in activity between arms with regards to the non-affected (dominant) arm. Also popular PROMs were completed: DASH score (range 0–100;0=best) and SST score (range 0–12; 0=best). Independent t-test, Mann-Whitney U test, Pearson's r correlations were performed. Results. No significant differences in activity duration (Healthy: 50%, patients: 57% of the day) and intensity of upper-extremity activity were found between patients and healthy subjects, although PROMs were significantly worse in patients. Patients and healthy subjects use both arms in similar amounts of time per day. This corresponds to the ratio which almost equals 1 and the low asymmetry values (<10%) in both groups. Also the amount activity in low and high intensity was comparable between affected (non-dominant) and non-affected (dominant) arm. No correlations were found between AM data and PROMs. Discussion and Conclusion. Patients and healthy subjects move their upper arms approximately 53% of the day. No differences in amount and intensity of upper-extremity activity were found between healthy subjects and patients, neither between both arms. This suggests that subjects perform daily activities independent of pain, complaints or arm dominance. It could also hint at the algorithm operating with a too low activity threshold to include shuffling or misclassifying excitations from walking as intense arm movement. Both issues can be adjusted by adjusting thresholds and filter settings. The asymmetry in upper-extremity activity of healthy subjects (9.1%) assumes that a 10% asymmetry in arm activity seems natural, which coincides with similar values reported for functional shoulder tests (Koerver et al. CORS 2010). The lack of correlations between AM and PROMs suggests that both measure different outcome dimensions. The AM has some limitations which should be considered when improving the clinical feasibility of upper-extremity activity monitoring. The AM only allows to measure acceleration-related activities (speed, intensity), while upper-extremity activity often involves static force-related activities. However, the inclinometer capacity of accelerometers allows to measure upper-extremity activity at different elevations (upper arm above/below shoulder). This may add qualitative information, relevant for clinical purposes


Bone & Joint Research
Vol. 5, Issue 7 | Pages 287 - 293
1 Jul 2016
Ismail H Phedy P Kholinne E Djaja YP Kusnadi Y Merlina M Yulisa ND

Objectives

To explore the therapeutic potential of combining bone marrow-derived mesenchymal stem cells (BM-MSCs) and hydroxyapatite (HA) granules to treat nonunion of the long bone.

Methods

Ten patients with an atrophic nonunion of a long bone fracture were selectively divided into two groups. Five subjects in the treatment group were treated with the combination of 15 million autologous BM-MSCs, 5g/cm3 (HA) granules and internal fixation. Control subjects were treated with iliac crest autograft, 5g/cm3 HA granules and internal fixation. The outcomes measured were post-operative pain (visual analogue scale), level of functionality (LEFS and DASH), and radiograph assessment.


Bone & Joint 360
Vol. 3, Issue 4 | Pages 35 - 38
1 Aug 2014
Hammerberg EM