A retrospective review of 80 patients with unilateral slipped capital femoral epiphysis from 1998–2012 was undertaken to determine the outcome of the unaffected hip. All patients were treated with either prophylactic single Richards screw fixation or observation of the uninvolved hip and were followed up for at least 12 months. The unaffected hip of 44 patients (mean age 12.6 years, range 9–17) had simultaneous prophylactic fixation and 36 patients (mean age 13.4 years, range 9–17.4) were managed with observation. Sequential slip of the unaffected hip was noted in 10 patients (28 per cent) in the observation group and only in 1 patient (2 per cent) in the group managed with prophylactic fixation. A Fisher's exact test showed significantly high incidence of sequential slip in unaffected hips when managed with regular observation (p-value 0.002). Only 3 cases had symptomatic hardware on the unaffected side after prophylactic fixation with one requiring revision of the metal work; one had superficial wound infection treated with antibiotics. No cases had AVN or chondrolysis.Methods
Results
Abstract. Objective. To assess the prevalence of acetabular retroversion in patients presenting with Slipped Upper Femoral Epiphysis using both validated radiological signs and CT-angle measurements. Methods. A retrospective review of all cases involving surgical management for acute SUFE presenting to the Royal Children's Hospital, Melbourne were assessed from 2012–2018. Pre-operative plain radiographs were assessed for slip angle, validated radiological signs of retroversion (post wall/crossover/ischial spine sign) and standardised post-operative CT Scans were used to assess cranial and mid-acetabular version. Results. 116 SUFEs presented in 107 patients who underwent surgical intervention; 47 females and 60 boys, with an average age of 12.7 years (range 7.5–16.6 years). Complete radiological data was available for 91 patients (99 hips) with adequate axial CT imaging of both hips. 82% patients underwent pinning in situ (PIS) with subcapital realignment surgery (SRS) performed in 18% (slip angles >75°).
The high risk and the associated high mortality of secondary,
Fragility fractures are an increasing cause of morbidity and mortality in the elderly population. Their association with reduced bone mineral density (BMD) is well documented. It is a reasonable assumption that hip fracture severity is linked to the magnitude of bone loss, (the lower the BMD, the more severe the fracture), however it is not known whether this correlation exists. Our aim therefore was to investigate the relationship between BMD and hip fracture severity. We reviewed 142 patients, 96 females and 46 males, mean age 74 years (49-92), who had sustained a hip fracture following a simple ground level fall. All had subsequently undergone DEXA bone scanning of the
Introduction. Patients with knee osteoarthritis (OA) often tell us that they put extra load on the joints of the opposite leg as they walk. Multiple joint OA is common and has previously been related to gait changes due to hip OA (Shakoor et al 2002). The aim of this study was to determine whether patients with medial compartment knee OA have abnormal biomechanics of the unaffected knee and both hips during normal level gait. Methods. Twenty patients (11 male, 9 female), with severe medial compartment knee OA and no other joint pain were recruited. The control group comprised 20 adults without musculoskeletal pain. Patients were reviewed, x-rays were examined and WOMAC and Oxford knee scores were completed. A 12 camera Vicon (Vicon, Oxford) system was used to collect kinematic data (100Hz) on level walking and the ground reaction force was recorded using three AMTI force plates (1000Hz). Surface electrodes were placed over medial and lateral quadriceps and hamstrings bilaterally to record EMG data (1000Hz). Kinematics and kinetics were calculated using the Vicon ‘plug-in-gait’ model. A co-contraction index was calculated for the EMG signals on each side of the knee, representing the magnitude of the combined readings relative to their maximum contraction during the gait cycle. Statistical comparisons were performed using t-tests with Bonferroni's correction for two variables and ANOVA for more than two variables (SPSS v16). Results. The mean age of the patients was 69 (SD 8.8). Mean gait speed was 0.95m/s (study group) and 1.44m/s (control group). Peak adduction moments for the OA group [OA Knee; Unaffected Knee; Ipsilateral
Second-generation metal-on-metal (MoM) articulations in total hip arthroplasty (THA) were introduced in order to reduce wear-related complications. The current study reports on the serum cobalt levels and the clinical outcome at a minimum of 20 years following THA with a MoM (Metasul) or a ceramic-on-polyethylene (CoP) bearing. The present study provides an update of a previously published prospective randomized controlled study, evaluating the serum cobalt levels of a consecutive cohort of 100 patients following THA with a MoM or a CoP articulation. A total of 31 patients were available for clinical and radiological follow-up examination. After exclusion of 11 patients because of other cobalt-containing implants, 20 patients (MoM (n = 11); CoP (n = 9)) with a mean age of 69 years (42 to 97) were analyzed. Serum cobalt levels were compared to serum cobalt levels five years out of surgery.Aims
Methods
Financial and human cost effectiveness is an increasing evident outcome measure of surgical innovation. Considering the human element, the aim is to restore the individual to their “normal” state by sparing anatomy without compromising implant performance. Gait lab studies have shown differences between different implants at top walking speed, but none to our knowledge have analysed differing total hip replacement patients through the entire range of gait speed and incline to show differences. The purpose of this gait study was to 1) determine if a new short stem femoral implant would return patients back to normal 2) compare its performance to established hip resurfacing and long stem total hip replacement (THR) implants. 110 subjects were tested on an instrumented treadmill (Kistler Gaitway, Amherst, NY), 4 groups (short-stem THR, long-stem THR, hip resurfacing and healthy controls) of 28, 29, 27, and 26 respectively. The new short femoral stem patients (Furlong Evolution, JRI) were taken from the ongoing Evolution Hip trial that have been tested on the treadmill with minimum 12months postop. The long stem total hip replacements and hip resurfacing groups were identified from out 800 patient gait database. They were only chosen if they were 12 months postop and had no other joint disease or medical comorbidities which would affect gait performance. All subjects were tested through their entire range of gait speeds and incline after having a 5 minute habituation period. Speed intervals were at 0.5kms increments until maximum walking speed achieved and inclines at 4kms for 5, 10, 15%. At all incremental intervals of speed, the vertical component of the ground reaction forces, center of pressure and temporal measurements were collected for both limbs with a sampling frequency of 100Hz. Body weight scaling was applied to correct for mass differences and a symmetry index to compare the implanted hip to the
Intramedullary fixation is considered the most stable treatment for pertrochanteric fractures of the proximal femur and cut-out is one of the most frequent mechanical complications. In order to determine the role of clinical variables and radiological parameters in predicting the risk of this complication, we analysed the data pertaining to a group of patients recruited over the course of six years. A total of 571 patients were included in this study, which analysed the incidence of cut-out in relation to several clinical variables: age; gender; the AO Foundation and Orthopaedic Trauma Association classification system (AO/OTA); type of nail; cervical-diaphyseal angle; surgical wait times; anti-osteoporotic medication; complete post-operative weight bearing; and radiological parameters (namely the lag-screw position with respect to the femoral head, the Cleveland system, the tip-apex distance (TAD), and the calcar-referenced tip-apex distance (CalTAD)).Objectives
Methods
In order to evaluate the relationship between acetabular and proximal femoral alignment in the initiation and evolution of osteoarthritis of the dysplastic hip, the acetabular and femoral angles were calculated geometrically from radiographs of 62 patients with pre-arthrosis and early osteoarthritis. The sum of the lateral opening angle of the acetabulum and the neck-shaft angle was defined as the lateral instability index (LII), and the sum of the anterior opening angle of the acetabulum and the anteversion angle of the femoral neck as the anterior instability index (AII). These two indices were compared in dysplastic and unaffected hips. A total of 22 unilateral hips with pre-arthrosis were followed for at least 15 years to determine whether the two indices were associated with the progression of osteoarthritis. The LII of the affected hips (197.4 (
Post-mortem retrieval of canine, cemented femoral components was analysed to assess the performance of these implants in the dog as a model for human total hip replacement (THR). Mechanical testing and radiological analysis were performed to determine the stability of the implant and the quality of the cement. Thirty-eight implants from 29 dogs were retrieved after time intervals ranging from 0.67 to 11.67 years. The incidence of aseptic loosening was 63.2%, much higher than in human patients (6% in post-mortem studies). Failure of the femoral implants began with debonding at the cement-metal interface, similar to that in implants in man. The incidence of aseptic loosening was much lower in bilateral than in unilateral implants. Significant differences were observed for three different designs of implant. While the dog remains the animal model of choice for THR, results from this study provide insight into interspecies differences in the performance of implants. For example, the performance of THR in dogs should be compared with that in young rather than in elderly human patients.