Advertisement for orthosearch.org.uk
Results 1 - 19 of 19
Results per page:
Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_9 | Pages 40 - 40
17 Apr 2023
Saiz A Kong S Bautista B Kelley J Haffner M Lee M
Full Access

With an aging population and increase in total knee arthroplasty, periprosthetic distal femur fractures (PDFFs) have increased. The differences between these fractures and native distal femur fractures (NDFF) have not been comprehensively investigated. The purpose of this study was to compare the demographic, fracture, and treatment details of PDFFs compared to NDFFs. A retrospective study of patients ≥ 18 years old who underwent surgical treatment for either a NDFF or a PDFF from 2010 to 2020 at a level 1 trauma center was performed. Demographics, AO/OTA fracture classification, quality of reduction, fixation constructs, and unplanned revision reoperation were compared between PDFF patients and NDFF patients using t-test and Fisher's exact test. 209 patients were identified with 70 patients having a PDFF and 139 patients having a NDFF. Of note, 48% of NDFF had a concomitant fracture of the ipsilateral knee (14%) or tibial plateau (15%). The most common AO/OTA classification for PDFFs was 33A3.3 (71%). NDFFs had two main AO/OTA classifications of 33C2.2 (28%) or 33A3.2. (25%). When controlling for patient age, bone quality, fracture classification, and fixation, the PDFF group had increased revision reoperation rate compared to NDFF (P < 0.05). PDFFs tend to occur in elderly patients with low bone quality, have complete metaphyseal comminution, and be isolated; whereas, NDFF tend to occur in younger patients, have less metaphyseal comminution, and be associated with other fractures. When controlling for variables, PDFF are at increased risk of unplanned revision reoperation. Surgeons should be aware of these increased risks in PDFFs and future research should focus on these unique fracture characteristics to improve outcomes


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_15 | Pages 45 - 45
1 Nov 2018
Barlow C Dominguez E Dixon G Crouch-Smith H Wallace R Simpson H Al-Hourani K
Full Access

Femoral shaft fractures are potentially devastating injuries. Despite this, clinical studies of the biomechanics of this injury are lacking. We aimed to clinically evaluate bone behaviour under high and low energy trauma in paediatric, adult and older patients. Single-centre retrospective study identifying all diaphyseal femoral fractures between Feb 2015-Feb 2017. Peri-prosthetic and pathological fractures were excluded. Patients were subdivided into groups 1 (paediatric, <16yo), 2 (adult, 17–55yo) and 3 (older, >55yo) to reflect immature, peak bone age and osteoporotic bone respectively. Chi-Squared analysis assessed significance of bone age to degree of comminution and fracture pattern. A p-value <0.05 was significant. A total 4130 radiographs were analysed with 206 femoral shaft fractures identified. Forty-three patients were excluded with 163 remaining. Group 1, 2 and 3 included 38, 37 and 88 patients respectively. Mean age 50.8 (SD 32.8) with male-to-female ratio of 1:1.2. Groups 1 and 3 included majority simple fractures (35/38 and 62/88 respectively). Group 2 included more comminuted injuries (33/37). Bone age to degree of comminution proved significant (p<0.05) with a bimodal distribution of simple fractures noted in groups 1 and 3. Energy to fracture was significant in group 2, where a high energy injury was associated with comminution (p<0.05). This study is the first to demonstrate an association between fracture comminution and age. Simple femoral shaft fractures showed a bimodal age distribution in paediatric and older patients regardless of mechanism energy. High energy mechanism trauma was directly related to fracture comminution at peak bone age


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_1 | Pages 41 - 41
2 Jan 2024
Singh S Dhar S Kale S
Full Access

The management of comminuted metaphyseal fractures is a technical challenge and satisfactory outcomes of such fixations often remain elusive. The small articular fragments and bone loss often make it difficult for standard fixation implants for proper fixation. We developed a novel technique to achieve anatomical reduction in multiple cases of comminuted metaphyseal fractures at different sites by employing the cantilever mechanism with the help of multiple thin Kirschner wires augmented by standard fixation implants. We performed a retrospective study of 10 patients with different metaphyseal fractures complicated by comminution and loss of bone stock. All patients were treated with the help of cantilever mechanism using multiple Kirschner wires augmented by compression plates. All the patients were operated by the same surgeon between November 2020 to March 2021 and followed up till March 2023. Surgical outcomes were evaluated according to the clinical and radiological criteria. A total of 10 patients were included in the study. Since we only included patients with highly unstable and comminuted fractures which were difficult to fix with traditional methods, the number of patients in the study were less. All 10 patients showed satisfactory clinical and radiological union at the end of the study with good range of motion. One of the patient in the study had post-operative wound complication which was managed conservatively with regular dressings and oral antibiotics. Comminuted metaphyseal fractures might differ in pattern and presentation with every patient and there can be no standard treatment for all. The cantilever technique of fracture fixation is based on the principle of cantilever mechanism used in bridges and helps achieve good anatomical reduction and fixation. It provides a decent alternative when standard modes of fixation don't give desired result owing to comminuted nature of fractures and deficiency of bone stock


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_7 | Pages 44 - 44
4 Apr 2023
Knopp B Harris M
Full Access

Our study seeks to determine whether characteristics of radiographs taken post-reduction of a forearm fracture can indicate future risk of refracture or loss of reduction. We hypothesize that reducing forearm fractures too precisely may be counterproductive and provide less benefit than reductions left slightly offset prior to cast immobilization. We conducted a retrospective review of 1079 pediatric patients treated for forearm fractures between January 2014 and September 2021 in a 327 bed regional medical center. Percent fracture displacement, location, orientation, comminution, fracture line visibility and angle of angulation were determined by AP and lateral radiographs. Percent fracture displacement was derived by: (Displacement of Bone Shafts / Diameter) x 100% = %Fracture Displacement. Patients treated with closed reduction were reduced from a mean displacement of 29.26±36.18% at an angulation of 22.67±16.57 degrees to 7.88±9.07% displacement and 3.89±6.68 degrees angulation post-reduction. Patients developing complications including a loss of reduction or refracture were found to have post-operative radiographs with a lower percent displacement (0.50±1.12) than those not developing complications (8.65±9.21)(p=0.0580). Post-reduction angulation (p=1.000), average reduction in angulation (p=1.000) and average reduction in displacement percent(p=0.2102) were not significantly associated with development of complications. Percent displacement of radial shafts was seen to be the most important metric to monitor in post-operative radiographs for patients undergoing closed reduction of a forearm fracture. We theorize a slight displacement provides greater surface area for osteoblastic expansion and callus formation leading to a decreased risk of refracture or loss of reduction. While our sample size precludes our ability to measure the ideal amount of post-reduction displacement for optimal healing, our results demonstrate that some degree of shaft displacement is required for optimal healing conditions


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_1 | Pages 56 - 56
2 Jan 2024
Zderic I Warner S Stoffel K Woodburn W Castle R Penman J Saura-Sanchez E Helfet D Gueorguiev B Sommer C
Full Access

Treatment of both simple and complex patella fractures is a challenging clinical problem. The aim of this study was to investigate the biomechanical performance of recently developed lateral rim variable angle locking plates versus tension band wiring used for fixation of simple and complex patella fractures. Twelve pairs of human anatomical knees were used to simulate either two-part transverse simple AO/OTA 34C1 or five-part complex AO/OTA 34C3 patella fractures by means of osteotomies, with each fracture model created in six pairs. The complex fracture pattern was characterized by a medial and a lateral proximal fragment, together with an inferomedial, an inferolateral, and an inferior fragment mimicking comminution around the distal patellar pole. The specimens with simple fractures were pairwise assigned for fixation with either tension band wiring through two parallel cannulated screws, or a lateral rim variable angle locking plate. The knees with complex fractures were pairwise treated with either tension band wiring through two parallel cannulated screws plus circumferential cerclage wiring, or a lateral rim variable angle locking plate. Each specimen was tested over 5000 cycles by pulling on the quadriceps tendon, simulating active knee extension and passive knee flexion within the range of 90° flexion to full knee extension. Interfragmentary movements were captured via motion tracking. For both fracture types, the longitudinal and shear articular displacements measured between the proximal and distal fragments at the central patella aspect between 1000 and 5000 cycles, together with the relative rotations of these fragments around the mediolateral axis were all significantly smaller following the lateral rim variable angle locked plating compared with tension band wiring, p<0.01. Lateral rim locked plating of both simple and complex patella fractures provides superior construct stability versus tension band wiring under dynamic loading


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_7 | Pages 23 - 23
4 Apr 2023
Stoffel K Zderic I Pastor T Woodburn W Castle R Penman J Saura-Sanchez E Gueorguiev B Sommer C
Full Access

Treatment of simple and complex patella fractures represents a challenging clinical problem. Controversy exists regarding the most appropriate fixation method. Tension band wiring, aiming to convert the pulling forces on the anterior aspect of the patella into compression forces across the fracture site, is the standard of care, however, it is associated with high complication rates. Recently, anterior variable-angle locking plates have been developed for treatment of simple and comminuted patella fractures. The aim of this study was to investigate the biomechanical performance of the novel anterior variable-angle locking plates versus tension band wiring used for fixation of simple and complex patella fractures. Sixteen pairs of human cadaveric knees were used to simulate either two-part transverse simple AO/OTA 34-C1 or five-part complex AO/OTA 34-C3 patella fractures by means of osteotomies, with each fracture model created in eight pairs. The complex fracture pattern was characterized with a medial and a lateral proximal fragment, together with an inferomedial, an inferolateral and an inferior fragment mimicking comminution around the distal patellar pole. The specimens with simple fractures were pairwise assigned for fixation with either tension band wiring through two parallel cannulated screws, or an anterior variable-angle locking core plate. The knees with complex fractures were pairwise treated with either tension band wiring through two parallel cannulated screws plus circumferential cerclage wiring, or an anterior variable-angle locking three-hole plate. Each specimen was tested over 5000 cycles by pulling on the quadriceps tendon, simulating active knee extension and passive knee flexion within the range from 90° flexion to full knee extension. Interfragmentary movements were captured by motion tracking. For both fracture types, the articular displacements, measured between the proximal and distal fragments at the central aspect of the patella between 1000 and 5000 cycles, together with the relative rotations of these fragments around the mediolateral axis were all significantly smaller following the anterior variable-angle locked plating compared with the tension band wiring, p < 0.01. From a biomechanical perspective, anterior locked plating of both simple and complex patella fractures provides superior construct stability versus tension band wiring


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_4 | Pages 94 - 94
1 Apr 2018
Patel A Li L Qureshi A Deierl K
Full Access

Introduction. Hoffa fractures are rare, intra-articular fractures of the femoral condyle in the coronal plane and involving the weight-bearing surface of the distal femur. Surgical fixation is warranted to achieve stability, early mobilisation and satisfactory knee function. We describe a unique type of Hoffa fracture in the coronal plane with sagittal split and intra-articular comminution. There is scant evidence in current literature with regards to surgical approaches, techniques and implants. We report of our case with a review of the literature. Case report. A 40 year old male motorcyclist was involved in a high speed road traffic collision. X-rays confirmed displaced unicondylar fracture of the lateral femoral condyle. CT showed sagittal split of the Hoffa fragment and intra-articular comminution. MRI showed partial rupture of the anterior cruciate ligament. The patient underwent definitive surgical treatment via a midline skin incision and lateral parapatellar approach using cannulated screws, headless compression screws and anti-glide plate. Weightbearing was commenced at 8 weeks. Arthroscopy and adhesiolysis was performed at 12 weeks to improve range of motion. The patient was discharged at one year with a pain-free, functional knee. Discussion. Hoffa fractures are high-energy fractures, often seen in young male motorcyclists with flexed and slightly abducted knee. Most papers recommend surgical fixation, however there is no widely accepted surgical method or rehabilitation regime. Varying surgical approaches, screw direction, choice of implants, and post-operative care have been described. Surgical approach depends on the configuration of the fracture. The medial/lateral parapatellar approach is commonly used as it does not compromise future arthroplasty, but it does not allow access to fix posterior comminution. Arthroscopic-assistance may be used with good outcomes and less tissue dissection. AP screws are widely reported in the literature, most likely due to easier access to the fracture site. PA screws may provide better stability, but access is more difficult. Fixation often involves passing screws through the articular surface, therefore the area damaged should be kept to a minimum by using the smallest possible screw; headless compression screws leave a smaller footprint in the articular cartilage. Locking plate augmentation generally gives good outcomes. Conclusion. Hoffa fractures are rare and difficult to treat. Surgical treatment is the best choice for optimum post-operative knee function. There is no consensus on choice of surgical approaches, techniques and implants, as these are dependent on fracture configuration. In this particular case we emphasise the importance of using an anti-glide plate to address the sagittal component. Despite the need for a secondary procedure, the treatment has had positive outcomes and may be used as a guide for treatment of future Hoffa fractures of a similar sub-type


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_2 | Pages 86 - 86
1 Mar 2021
Bommireddy L Granville E Davies-Jones G Gogna R Clark DI
Full Access

Abstract. Objectives. Clavicle fractures are common, yet debate exists regarding which patients would benefit from conservative versus operative management. Traditionally shortening greater than 2cm has been accepted as an indicator for surgery. However, clavicle length varies between individuals. In a cadaveric study clavicle shortening greater than 15% was suggested to affect outcomes. There is no clinical correlation of this in the literature. In this study we investigate outcomes following middle third clavicle fractures and the effect of percentage shortening on union rates. Methods. We identified a consecutive series of adults with primary midshaft clavicle fractures presenting to our institution from April 2015-March 2017. Clinical records and radiographs were reviewed to elicit outcomes. Time to union was measured against factors including; percentage shortening, displacement, comminution and smoking. Statistical significance was calculated. Results. 127 patients were identified, of whom 90 were managed conservatively and 37 operatively. Fractures were displaced in 86 patients (68%). Mean age was 41.7 years (range 18–89). Mean time to union for displaced fractures was longer than for undisplaced at 13.4 and 8.9 weeks respectively (p=0.0948). Displaced fractures treated operatively had mean time to union of 12.8 weeks, three weeks shorter than those managed conservatively (p=0.0470). Mean time to union for fractures with >15% shortening was 16.0 weeks, nearly double the 8.7 weeks with <15% shortening (p= 0.0241). Smokers had 8 weeks longer time to union (p=0.0082). Nonunion rate was 10% in fractures managed conservatively and 0% in those treated operatively. Complications following operative management were plate removal (13.5%), frozen shoulder (8.1%) and infection (2.9%). Conclusions. Nonunion rate is higher in fractures managed conservatively. Shortening >15% leads to significantly longer union time and should therefore be used as an indicator for surgery. Displacement and smoking also lengthen time to union and should be considered in the operative decision process. Declaration of Interest. (b) declare that there is no conflict of interest that could be perceived as prejudicing the impartiality of the research reported:I declare that there is no conflict of interest that could be perceived as prejudicing the impartiality of the research project


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_4 | Pages 23 - 23
1 Mar 2021
Schopper C Zderic I Menze J Muller D Rocci M Knobe M Shoda E Richards G Gueorguiev B Stoffel K
Full Access

Femoral neck fractures account for half of all hip fractures and are recognized as a major public health problem associated with a high socioeconomic burden. Whilst internal fixation is preferred over arthroplasty for physiologically younger patients, no consensus exists about the optimal fixation device yet. The recently introduced implant Femoral Neck System (FNS) (DePuy Synthes, Zuchwil, Switzerland) was developed for dynamic fixation of femoral neck fractures and provides angular stability in combination with a minimally invasive surgical technique. Alternatively, the Hansson Pin System (HPS) (Swemac, Linköping, Sweden) exploits the advantages of internal buttressing. However, the obligate peripheral placement of the pins, adjacent to either the inferior or posterior cortex, renders the instrumentation more challenging. The aim of this study was to evaluate the biomechanical performance of FNS versus HPS in a Pauwels II femoral neck fracture model with simulated posterior comminution. Forty-degree Pauwels II femoral neck fractures AO 31-B2.1 with 15° posterior wedge were simulated in fourteen paired fresh-frozen human cadaveric femora, followed by instrumentation with either FNS or HPS in pair-matched fashion. Implant positioning was quantified by measuring the shortest distances between implant and inferior cortex (DI) as well as posterior cortex (DP) on anteroposterior and axial X-rays, respectively. Biomechanical testing was performed in 20° adduction and 10° flexion of the specimens in a novel setup with simulated iliopsoas muscle tension. Progressively increasing cyclic loading was applied until construct failure. Interfragmentary femoral head-to-shaft movements, namely varus deformation, dorsal tilting and rotation around the neck axis were measured by means of motion tracking and compared between the two implants. In addition, varus deformation and dorsal tilting were correlated with DI and DP. Cycles to 5/10° varus deformation were significantly higher for FNS (22490±5729/23007±5496) versus HPS (16351±4469/17289±4686), P=0.043. Cycles to 5/10° femoral head dorsal tilting (FNS: 10968±3052/12765±3425; HPS: 12244±5895/13357±6104) and cycles to 5/10° rotation around the femoral neck axis (FNS: 15727±7737/24453±5073; HPS: 15682±10414/20185±11065) were comparable between the implants, P≥0.314. For HPS, the outcomes for varus deformation and dorsal tilting correlated significantly with DI and DP, respectively (P=0.025), whereas these correlations were not significant for FNS (P≥0.148). From a biomechanical perspective, by providing superior resistance against varus deformation and performing in a less sensitive way to variations in implant placement, the angular stable Femoral Neck System can be considered as a valid alternative to the Hansson Pin System for the treatment of Pauwels II femoral neck fractures


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_9 | Pages 71 - 71
1 May 2017
Formoy E Ekpo E Thomas T Kocialkowski C Pillai A
Full Access

Background. Reduced bone mineral density is recognised as a risk factor for hip fractures and fragility fractures in general. Vitamin D is important in maintaining healthy bone mineral levels and can therefore affect risk of hip fracture. We investigated the correlation between vitamin D levels and bone mineral density, as well as fracture type, in neck of femur fractures and also assessed the relationship of vitamin D and social deprivation. Method. We included all patients admitted to our department, with a neck of femur fracture over one year (October 2013 to October 2014). We analysed vitamin D levels for all patients during admission and compared these to bone mineral density scores, based on DEXA scan results; hip fracture type & comminution, based on admission radiographs; and levels of social deprivation, based on the patient's address. Results. In total 360 patients were admitted over the study period, with a neck of femur fracture, of which 298 had vitamin D assessed and 76 had DEXA scans. Of these cohorts, 71% were found to be vitamin D deficient and 7% had osteoporosis. No significant correlation was found between vitamin D scores and bone density, or with level of vitamin D deficiency and fracture type or comminution. A significant correlation was however identified, between low vitamin D levels and decreasing levels of social deprivation (R=0.11, p=0.04). Conclusion. No relationship was identified between vitamin D levels and hip fracture type, suggesting that vitamin D cannot be used to predict patients at risk of more comminuted fractures. Although no relationship was also identified for bone mineral density and vitamin D, this may be because the sample size of DEXA scans was relatively small. Interestingly the relationship between vitamin D and social deprivation was the reverse of what was expected and suggests that affluent individuals may be at greater risk of low vitamin D


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVI | Pages 116 - 116
1 Aug 2012
Theobald P Qureshi A Jones M
Full Access

Long bone fractures are a commonly presented paediatric injury. Whilst the possibility of either accidental or non-accidental aetiology ensures significant forensic relevance, there remain few clinical approaches that assist with this differential diagnosis. The aim of this current study was to generate a reproducible model of spiral fracture in immature bone, allowing investigation of the potential relationship between the rotational speed and the angle of the subsequent spiral fracture. Seventy bovine metacarpal bones were harvested from 7 day old calves. Sharp dissection ensured removal of the soft tissue, whilst preserving the periosteum. The bones were then distributed evenly before eleven groups, before being aligned along their central axis within a torsional testing machine. Each group of bones were then tested to failure at a different rotational speed (0.5, 1, 15, 20, 30, 40, 45, 60, 75, 80 and 90 degrees s-1). The angle of spiral fracture, relative to the long axis, was then measured, whilst the fracture location, the extent of comminution and periosteal disruption, were all recorded. Sixty-two out of 70 specimens failed in spiral fracture, with the remaining tests failing at the anchorage site. All bone fractures centred on the narrowest waist diameter, with 5 specimens (all tested at 90 degrees s-1) demonstrating comminution and periosteal disruption. The recorded spiral fracture angles ranged from 30 - 45 degrees, and were dependant on the rotational speed. This study has established a relationship between the speed of rotation and the angle of spiral fracture in immature bovine bone. It is anticipated that further study will enable investigation of this trend in paediatric bone, ultimately providing an additional diagnostic tool for clinicians trying to verify the proposed mechanism of injury


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_8 | Pages 65 - 65
1 Apr 2017
Patel A Li L Rashid A
Full Access

Background. Radial head fractures are the commonest fractures involving the elbow. The goals of treatment are to restore stability, preserve motion, and maintain the relative length of the radius. Fortunately, most simple uncomplicated fractures can be treated non-operatively. Choosing between fixation and radial head replacement for comminuted fractures remains difficult. Excision of radial head fractures is not an ideal option in unstable elbow injuries. The purpose of this systematic review was to search for and critically appraise articles directly comparing functional outcomes and complications for fixation (open reduction internal fixation, ORIF) versus arthroplasty for comminuted radial head fractures (Mason type 3) in adults. Method. A comprehensive search of Medline, Embase and Cochrane databases using specific search terms and limits was conducted. Strict eligibility criteria were applied to stringently screen resultant articles. Three comparative studies were identified and reviewed. Results. Three comparative studies were identified and reviewed: two studies found significantly better Broberg & Morrey functional scores after replacement compared with ORIF in Mason type 3 fractures. The third study found no significant differences in Mayo functional score or range of motion, but did find that grip strength was better after ORIF. Complication rates were too heterogenous for conclusion. Conclusion. Fixation with good reduction may be attempted in unstable Mason type 3 fractures, and arthroplasty may be considered if this is not possible. Further randomised comparative trials are required to clarify the decision-making between fixation and replacement. Functional outcomes and complications were conflicting in the studies included here. Ideally, treatment decision should take into account elbow stability and degree of comminution


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_1 | Pages 87 - 87
1 Jan 2017
Basci O Erduran M Acan A Uzun B Karakasli A
Full Access

Basic engineering principles dictate that unplugged screw holes serve as sites of the concentration of stress and the initiation and growth of cracks (1,2). The idea of filling the holes were tested previously in the literature showing promising results (3). However there's either adverse results which might be a design mistake (4). The purpose of this study was to determine if the use of specially designed screw hole inserts in empty locking screw holes improves the strength and failure characteristics of locking plates. Forty two 7-hole locking LC/DCP plates were mounted on cylindric UHMW Polyethylene blocks with a 1-cm gap between blocks, simulating a fracture with comminution and bone loss. 21 plates had a screw hole insert placed in the center hole (centered over the simulated fracture), while 21 of the plates remained empty in the center hole. The plate–block constructs were placed in a mechanical testing machine and subjected to a series of loading conditions. The axial, bending and torsional stiffness and displacements needed for failure of each plate-block construct was calculated. The Statistical analysis was performed by Mann Whitney-U test for independent variables. All plates were then loaded to failure. There were significant difference in the axial load to failure (p=0.017), bending load to failure (p<0.01) and bending diplacements (p<0.01) of the test groups favoring the screw hole insert group as a higher mechanical strength. In conclusion the study demonstrates that the addition of the specially designed locking screw hole insert does significantly change the stength of the locking LC/DCP plates and might be suggested in the clinical application


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_8 | Pages 103 - 103
1 Apr 2017
Kocialkowski C Peach C
Full Access

Background. Functional outcomes of conservatively managed, valgus impacted proximal humeral fractures are poor. Operative fixation can improve results but can be technically challenging. We prospectively assessed outcomes following fixation of valgus unstable proximal humeral fractures with a novel hybrid fixed angle blade plate, at a minimum of 12 months follow up. Methods. A new hybrid fixed angle blade plate design (Fx Plate, Exactech, Gainesville, USA) was used by the senior author to treat patients with displaced and potentially valgus unstable proximal humeral fractures, at our institution between November 2012 and March 2014. The study was approved by the research and development department. Outcomes were prospectively assessed using the Oxford and Constant shoulder scores and quality of life was assessed using the SF-36 questionnaire. Radiographs were taken at regular intervals to assess fracture healing. Results. In total 12 patients were identified and included in the study. All patients had comminution of the medial calcar, with potentially valgus unstable fracture patterns. Six of the patients had two-part displaced fractures, whereas six had three and four-part fractures. One patient died for reasons unrelated to surgery and three others were lost to follow up. Average follow up after surgery was 15.4 months (Range 12–20 months). At final follow up the average Oxford Shoulder Score was 41 (35 to 48) and Constant Score 73 (60 to 87), indicating a good functional outcome of the operated side. The average physical and mental component scores of the SF-36 questionnaire were 49 and 52 respectively, suggesting a good overall quality of life. Radiographs, taken at final follow up, confirmed fracture union in all cases. No significant complications occurred following surgery. Conclusions. Patients with displaced, potentially valgus unstable, proximal humeral fractures remain a challenging cohort to treat. Our results, however, indicate good functional and radiographic outcomes when using a novel hybrid fixed angle blade plate


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_13 | Pages 5 - 5
1 Mar 2013
Wallace R Simpson A
Full Access

Aim. To investigate the effects of strain rate and mineral level on the stress at failure, stiffness and toughness of whole bones. Methods. 40 ovine femurs were harvested and subjected to either slow [8.56 × 10−3 s−1 (± 1.42 × 10−3 SD)] or dynamic [17.14 s−1 (± 8.20 SD)] loading. Half the bones were demineralised by 20% compared to the original mineral content. These were allocated evenly between the high and low strain rate groups. Dynamic loading was achieved by custom designed comminution device. Slow rate testing was carried out on a Zwick/Roell z005 testing machine. Results. Strain rate was found to increase the Young's modulus in both the normal and demineralised bone. Additionally the toughness of the bones at failure was found to reduce with increasing strain rate. When comparing bone of normal quality the stress at failure was found to increase with strain rate. However, this effect was greatly reduced when comparing the effect of strain rate on the stress occurring in demineralised bones. Discussion. These results show that bone has an ability to withstand higher than normal stresses if these are applied quickly and for a short duration (such as would occur in a traumatic event). This ability is greatly reduced when the bone is of reduced mineral content, such as is found in aged or diseased bone


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_11 | Pages 74 - 74
1 Jul 2014
Brandolini N Kapur N Hall R
Full Access

Summary Statement. Burst fractures were simulated in vitro on human cadaveric spine segments. Displacement of the facet joints and pedicles were measured throughout the fracture process showing how these bony structures behave when an impact load is delivered. Introduction. Burst fractures account for almost 30% of all spinal injuries, which may result in severe neurological deficit, spinal instability and hence life impairment. 1. The onset of the fracture is usually traumatic, caused by a high-energy impact loading. Comminution of the endplates and vertebral body, retropulsion of fragments within the canal and increase of the intrapedicular distance are typical indicators of the injury. Experimental and numerical studies have reported strain concentration at the base of the pedicles, suggesting that the posterior processes play a fundamental role in the fracture initiation. 2,3. However, little is known about the dynamic behaviour of the vertebra undergoing an impact load. The aim of this study was to provide an in vitro cadaveric investigation on burst fracture, focusing on the widening of the facet joints and pedicles during the fracture development. Methods. Eight three-adjacent-vertebrae segments (T9-T10-T11, T12-L1-L2, L3-L4-L5) were harvested from three human spines preserving the ligaments and intervertebral discs. A testing frame was designed to hold the sample whilst undergoing an axial impact load (delivered through a drop-weight rig). Lateral displacement was recorded by two transducers (LVDT) sampled at 5000 Hz and data were used to calculate the percent maximum dynamic widening (MW) and percent residual widening after the impact (RW). LVDTs were positioned in contact with the most lateral region of the cranial facet joints where the central vertebra was lumbar; or posteriorly to the base of the pedicles for thoracic. Samples were divided into two groups to achieve two different grade of severity of the fracture by delivering two different amount of energy: High (HE) and Low (LE). Samples underwent HR-pQCT scanning prior and after fracturing to assess percent canal narrowing (CN), intrapedicular distance and grade the fracture. Differences between results were assessed using Mann-Whitney U test. Results. Burst fractures were induced in all the samples (fragment retropulsion was present in all HE samples). The median energy delivered to each group was 206J (HE) and 148J (LE) which led to a significant difference in the median CN (HE: 32.4%; LE: 11.8%; p=0.029). No significant difference was found between HE and LE in terms of MW (p=0.11), or RW (p=0.85). Furthermore, MW and CN were poorly correlated (R. 2. =0.13). In all the cases, the first peak in the widening data coincided with MW (median 12.8%, range 4.3–21.8%). RW measurements (median 2.8%, range −1.3–11.5%) were validated against HR-pQCT scans showing excellent agreement (R. 2. =0.93). Discussion/Conclusion. Results from this study provided further insight on the burst fracture process supporting the wedging effect of the adjacent facet joints when the impact load is transmitted. Indeed, the pedicles were forced to widen up to a critical value (MW), after which they fractured. Further experiments will help clarifying the influence of the amount of energy delivered


Bone & Joint Research
Vol. 4, Issue 11 | Pages 176 - 180
1 Nov 2015
Mirghasemi SA Rashidinia S Sadeghi MS Talebizadeh M Rahimi N

Objectives

There are various pin-in-plaster methods for treating fractures of the distal radius. The purpose of this study is to introduce a modified technique of ‘pin in plaster’.

Methods

Fifty-four patients with fractures of the distal radius were followed for one year post-operatively. Patients were excluded if they had type B fractures according to AO classification, multiple injuries or pathological fractures, and were treated more than seven days after injury. Range of movement and functional results were evaluated at three and six months and one and two years post-operatively. Radiographic parameters including radial inclination, tilt, and height, were measured pre- and post-operatively.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 2 | Pages 265 - 272
1 Feb 2007
Ristiniemi J Flinkkilä T Hyvönen P Lakovaara M Pakarinen H Jalovaara P

External fixation of distal tibial fractures is often associated with delayed union. We have investigated whether union can be enhanced by using recombinant bone morphogenetic protein-7 (rhBMP-7).

Osteoinduction with rhBMP-7 and bovine collagen was used in 20 patients with distal tibial fractures which had been treated by external fixation (BMP group). Healing of the fracture was compared with that of 20 matched patients in whom treatment was similar except that rhBMP-7 was not used.

Significantly more fractures had healed by 16 (p = 0.039) and 20 weeks (p = 0.022) in the BMP group compared with the matched group. The mean time to union (p = 0.002), the duration of absence from work (p = 0.018) and the time for which external fixation was required (p = 0.037) were significantly shorter in the BMP group than in the matched group. Secondary intervention due to delayed healing was required in two patients in the BMP group and seven in the matched group.

RhBMP-7 can enhance the union of distal tibial fractures treated by external fixation.


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 2 | Pages 261 - 266
1 Feb 2005
Földhazy Z Arndt A Milgrom C Finestone A Ekenman I

Strains applied to bone can stimulate its development and adaptation. High strains and rates of strain are thought to be osteogenic, but the specific dose response relationship is not known. In vivo human strain measurements have been performed in the tibia to try to identify optimal bone strengthening exercises for this bone, but no measurements have been performed in the distal radial metaphysis, the most frequent site of osteoporotic fractures. Using a strain gauged bone staple, in vivo dorsal metaphyseal radial strains and rates of strain were measured in ten female patients during activities of daily living, standard exercises and falls on extended hands. Push-ups and falling resulted in the largest compression strains (median 1345 to 3146 με, equivalent to a 0.1345% to 0.3146% length change) and falling exercises in the largest strain rates (18 582 to 45 954 με/s). On the basis of their high strain and/or strain rates these or variations of these exercises may be appropriate for distal radial metaphyseal bone strengthening.