Advertisement for orthosearch.org.uk
Results 1 - 3 of 3
Results per page:
Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 139 - 139
1 Sep 2012
Topolovec M Milosev I Coer A Bloebaum R
Full Access

Background. Wear particles are considered to be the major culprit for the aseptic loosening. Their characterization is thus crucial for the understanding of their bioreactivity and contribution to the development of aseptic loosening. Methods. Metal wear debris particles were analyzed directly in periprosthetic tissue resins by scanning electron microscopy (SEM) combined with back-scattered electron imaging (BSE) and energy dispersive X-ray spectroscopy (EDS). Four groups of tissue samples retrieved at revision operations of loosened hip implants with different bearing surfaces (metal-on-metal, ceramic-on-polyethylene and metal-on-polyethylene), and different material of the femoral stem (Ti alloy, CoCrMo and polymer combined with stainless steel) were investigated. Tissue samples were first analyzed histologicaly. Sections from the same paraffin blocks were then carbon coated and analyzed using SEM/BSE/EDS method. Results. Metal particles were detected in all samples. Their composition corresponded to the composition of the implant components. The gradation of metal particles ranged from +1 to +3. A considerable number of big metal particles were actually agglomerates of submicron particles visible only at higher magnification. The clustering of particles was observed primarily for CoCrMo and, to a lesser extent, for stainless steels particles. The median sizes of CoCrMo clusters in two groups of samples were 2.9 1.8 m (range, 0.5 to 7.6 m) and 3.2 1.0 m (range, 1.9 to 5.4 m). The effect of clustering was not observed for Ti particles. The median sizes of individual Ti particles determined in two groups of samples were 2.5 3.6 m (range, 0.4 to 17.3 m) and 4.3 2.8 m (range, 0.8 to 11.0 m). Conclusion. Scanning electron microscopy combined with back-scattered electron imaging is an appropriate and selective method to recognize metal particles in tissue sections, without being destructive to specimens. When the size of the particles is considered, however, it should be differed between the size of individual particles and size of clusters of particles. Besides its benefits, this study has some limitations: the detection of particles smaller than 0.4 m is difficult, and this method cannot be used to identify polyethylene particles


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 323 - 323
1 Sep 2012
Li C Hussain A Joseph P Kamali A
Full Access

INTRODUCTION. One of the recent advances in the hard-on-hard hip arthroplasty is the development of a new material of diffusion hardened oxidised zirconium (DHOxZr). The DHOxZr material consists of a ceramic layer on the top surface which is supported by a thick oxygen diffusion hardened (DH) zone underneath. With the desired properties of metal substrate, ceramic surface and a gradient structure of the oxygen diffusion zone, the DHOxZr-on-DHOxZr bearing combination is expected to produce low wear and minimal metal ions. This can possibly address the concerns associated with metal hypersensitivity associated with metal on metal bearings and fracture risk associated with ceramics. The aim of this study was to evaluate the wear of DHOxZr-on-DHOxZr as a possible hard on hard bearing combination in hips. METHODS. Three pairs of 50 mm DHOxZr prototype hip joint devices, each consisting of a DHOxZr modular head and a DHOxZr liner were wear tested in a ProSim hip joint simulator under standard testing conditions used by the Implant Development Centre (IDC), Smith & Nephew, Leamington Spa for 5 million cycles (Mc). The flexion/extension was 30° and 15°. The internal/external rotation was ± 10°. The force was Paul-type stance phase loading, with a maximum load of 3 kN and a standard ISO swing phase load of 0.3 kN. The test frequency was 1 Hz. Gravimetric analysis was carried out at 0, 0.5, 1, 2, 3, 4 & 5 million cycles. The lubricant was new born calf serum with 2 g/l sodium azide concentration diluted with de-ionised water to achieve average protein concentration of 20 g/l. Lubricant was changed every 0.25Mc during the first million cycles of the test and at every 0.33 Mc from 1 to 5Mc. RESULTS. A biphasic wear pattern was observed for the DHOxZr on DHOxZr devices during the test, with a running in phase from 0–1 Mc and a steady state phase from 1–5 Mc. At a confidence level of 95%, the mean wear rate was 0.21 ±0.06 mm3/Mc during the running-in stage, and the wear rate was reduced to 0.01 ±0.03 mm3/Mc during the steady state for the device tested. The wear volume loss of the DHOxZr on DHOxZr devices was significantly lower than that generated by CoCrMo metal on metal (MoM) devices (p < 0.05) under identical simulator test conditions


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 142 - 142
1 Sep 2012
Traynor A Simpson D Ellison P Collins S
Full Access

Introduction. Cobalt chrome on polyethylene remains a widely used bearing combination in total joint replacement. However wear induced osteolysis, bulk material property degradation of highly cross-linked polyethylene (HXLPE) [1], and oxidation after implantation (thought to be as a result of lipid absorption or cyclic loading [2]) remains a concern. ECIMA is a cold-irradiated, mechanically annealed, vitamin E blended next generation HXLPE developed to maintain mechanical properties, minimise wear and to improve the oxidation resistance in the long-term. The aim of this study was to compare the in-vitro wear rate and mechanical properties of three different acetabular liners; conventional UHMWPE, HXLPE and ECIMA. Methods. Twelve liners (Corin, UK) underwent a 3 million cycle (mc) hip simulation. Three conventional UHMWPE liners (GUR1050, Ø32 mm, 30 kGy sterilised in Nitrogen), three HXLPE liners (GUR1020, Ø40 mm, 75 kGy cross-linking and EtO sterilised) and six ECIMA liners (0.1 wt% vitamin E GUR1020, Ø40 mm, 120 kGy cross-linking, mechanically deformed and annealed, and EtO sterilised) articulated against CoCrMo alloy femoral heads to ASTM F75 (Corin, UK). Wear testing was performed in accordance with ISO 14242 parts 1 and 2, with a maximum force of 3.0 kN and at a frequency of 1 Hz. The test lubricant used was calf serum with a protein content of 30 g/l and 1% (v/v) patricin added as an antibacterial agent. Volumetric wear rate was determined gravimetrically after the first 0.5 mc and every 1 mc thereafter. ASTM D638 type V specimens (3.2 mm thick) were machined from ECIMA material for uniaxial tension testing to ASTM D638. Ultimate tensile strength (UTS), yield strength and elongation values were measured. These values were compared to mechanical data available for the other material types. Results. There was a 94% and a 68% reduction in the wear rate for the ECIMA liners compared to the conventional UHMWPE and HXLPE liners respectively. There was an increase in UTS, yield strength and elongation of 11%, 11% and 15% respectively, for ECIMA compared to HXLPE. Discussion. The wear results reported in this study indicate that ECIMA is a very low wearing material which has the potential to reduce wear related osteolysis in-vivo. Importantly, the mechanical properties were generally maintained unlike the degradation found in many modified polyethylene materials and were more comparable to conventional UHMWPE than HXLPE. The reduced wear rate during in-vitro hip simulation of ECIMA compared to conventional UHMWPE, coupled with improved mechanical properties in comparison to HXLPE, makes ECIMA a promising next generation, advanced bearing material