Introduction and Objective. Ceramic on Ceramic bearings in Total Hip Arthroplasty (THA) afford a low friction coefficient, low wear rates and extreme hardness. Significant complications include hip squeak,
This was a retrospective study of registry data from a National Orthopaedic Hospital for all THRs with 10-year follow-up data. Inclusion criteria were all THRs with a minimum of 10-year follow-up data. All metal-on-metal (MoM) THRs and MoM resurfacings were excluded from the analysis due to the high rate of revision associated with these bearings. Univariate and multivariate analyses controlling for confounding variables were performed to compare outcomes. A total of 1,697 THRs were performed in 1,553 patients. The four significant predictors for revision were fixation type (p<0.01), surface bearing type (p<0.01), age (P<0.05) and head size (p<0.05). Gender, BMI and approach had no effect on revision rates. The lowest 10-year all-cause revision rates were seen in cemented THRs at 1.7%. Ceramic-on-poly bearings had the lowest revision rate at only 1.2%. Metal-on-poly bearings had a 1.7% revision rate. Ceramic on ceramic bearings had a 7.1% revision rate with 1 revision for squeak and 1 revision for
Introduction. The purpose of this study was to evaluate the functional and radiographical results in patients younger than 30 years who underwent cementless third generation ceramic-on-ceramic total hip arthroplasty for osteonecrosis of the femoral head. Methods. Forty one patients (55 hips) who underwent total hip arthroplasty with third generation ceramic-on-ceramic bearings for osteonecrosis of the femoral head with a minimum 4-year follow-up were included in this study. There were 26 men and 15 women who had a mean age of 26 years (range, 16 to 29 years). The average duration of follow-up was 6 years (range, 4 to 7 years). All surgeries were done by a single hip surgeon and third generation ceramic-on-ceramic articulations were used. Securefit (Stryker) acetabular components were used in 46 hips and Duraloc (Depuy) in 9 hips. Accolade (Stryker) femoral stems were used in 33 hips, cone prosthesis (Zimmer) in 18 hips and CLS (Zimmer) in 4 hips. Functional results were measured by Harris hip (HHS) and WOMAC scores. Radiographic evaluation was assessed for loosening and osteolysis according to Gruen and Delee and Charnley criteria. Results. The average HHS improved from 53 points (range, 24 to 59 points) pre-operatively to 95 points (range, 88 to 100 points) at last follow-up. WOMAC scores improved from 72 points (range, 50 to 98 points) to 25 points (range, 21 to 37 points). Thirty nine patients (51 hips) continued their normal occupation. There was no aseptic loosening, osteolysis, and no prosthesis had been revised. There was one patient who complained of continuous squeaking and two patients with Brooker grade I heterotopic ossification. There were no other major complications such as
Ceramic-on-ceramic (CoC) total hip arthroplasty (THA) can produce articular noise during the normal activities, generating discomfort to the patient. THA noise has to be investigated also as a potential predictor and a clinical sign of prosthetic failure. An observational study has been carried out to characterize the noise in CoC cementless THA, and to analyze the related factors. A total of 46 patients with noisy hip have been enrolled in 38 months, within the follow-up protocol normally applied for the early diagnosis of
Our study aimed to examine not only the incidence but also the
impact of noise from two types of total hip replacement articulations:
ceramic-on-ceramic and ceramic-on-polyethylene. We performed a case-controlled study comparing subjective and
objective questionnaire scores of patients receiving a ceramic-on-ceramic
or a ceramic-on-polyethylene total hip replacement by a single surgeon.Objectives
Methods