Advertisement for orthosearch.org.uk
Results 1 - 13 of 13
Results per page:
The Bone & Joint Journal
Vol. 103-B, Issue 6 Supple A | Pages 94 - 101
1 Jun 2021
Roy ME Whiteside LA Ly KK Gauvain MJ

Aims. The aims of this study were to evaluate wear on the surface of cobalt-chromium (CoCr) femoral components used in total knee arthroplasty (TKA) and compare the wear of these components with that of ceramic femoral components. Methods. Optical profilometry was used to evaluate surface roughness and to examine the features created by the wear process in a knee wear simulator. We developed a method of measuring surface changes on five CoCr femoral components and quantifying the loss of material from the articular surface during the wear process. We also examined the articular surface of three ceramic femoral components from a previous test for evidence of surface damage, and compared it with that of CoCr components. Results. We found that the surface roughness of CoCr components rapidly increased during the first 1,000 wear cycles, then reached a steady state, but material loss from the surface continued at a rate of 1,778,000 μm. 3. per million cycles as carbides were removed from its matrix. These carbides formed third-body wear particles, leading to the formation of new scratches even as older scratches were worn away. In contrast, no scratching, loss of material, or other surface damage, when evaluated with one nanometer resolution, was found on the surface of the ceramic components after a 15 M wear cycle test. Conclusion. This study showed wear and loss of CoCr material from scratching and microabrasive wear in TKA. The material loss from the surface continued in a linear relationship with increasing cycles. We also found the absence of scratching and roughening of ceramic femoral components in simulated wear, suggesting an advantage in wear rate and avoiding metal sensitivity. This may have implications in the management of persistent pain after TKA. Cite this article: Bone Joint J 2021;103-B(6 Supple A):94–101


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_7 | Pages 31 - 31
1 Jul 2022
Lodge C Matar H Berber R Radford P Bloch B
Full Access

Abstract. Aims. Ceramic coatings in total knee arthroplasty have been introduced with the aim of reducing wear and consequently improving implant survivorship. We studied both cobalt-chrome-molybdenum and ceramic-coated components of the same implant design from a single centre to identify if the ceramic coating conferred any benefit at mid-term review. Patients and Methods. We identified 1641 Columbus TKAs (Aesculap AG, Tüttlingen, Germany) from a prospectively collected arthroplasty database. 983 were traditional CoCrMo and 659 had the AS ceramic coating. Patients were followed up until death or revision of the implant. Results. A slightly younger patient population was seen in the AS ceramic cohort which was statistically significant, mean 68.3 (p=<0.0001). There was no significant difference in implant survivorship between the CoCrMo femur and the ceramic coated femur at a mean of 9.2 years follow-up for the CoCrMo group and 5 years for the ceramic coated group (p=0.76). There was no reduction in the proportion of components revised for aseptic loosening or infection in the ceramic coated cohort. Conclusion. The reported benefits of ceramic coatings are note clearly demonstrated within our current cohort. All knee replacements within our cohort were performed by a user of both CoCrMo and AS and therefore implant familiarity does not explain the revision rate within the AS cohort. At mid-term follow-up, there was no benefit in terms of implant survivorship in using a ceramic coating


Introduction. Total knee arthroplasty (TKA) femoral components are known to wear and roughen with clinical use, and reaction to metal is a well-documented complication of TKA. Ceramic materials are resistant to wear and corrosion, but the surface wear of ceramic femoral components in TKA has not been reported. This study measured the changes in roughness and mass lost from cobalt-chromium (CoCr) femoral components tested in a knee simulator, and compared them to those observed in ceramic components. Methods. Six cast CoCr femoral components were tested in a knee simulator bearing against UHMWPE, with high-kinematics/high-load waveforms. Roughness and scratches were measured via optical profilometry. Scratch volume was equated to mass lost from abrasive wear, while nano-particulate wear and corrosion were estimated from the change in the distance of the surface to the depth of the scratches after increasing numbers of cycles. Three magnesia-stabilized zirconia femoral components that had been wear tested to 15 million cycles were compared with the CoCr components. Results. After 500,000 cycles, the CoCr femoral components were visibly scratched and measurably roughened (average roughness Sa = 38.4nm, vs. 22.2nm for never-implanted components; p < 0.0001). The ceramic components were not scratched or roughened (Sa = 18.5nm). The CoCr components had an average of 7.5μg lost due to scratches (0.0018mm. 3. per million cycles). The material lost due to nanoparticulate wear and corrosion was estimated at 1.5μg. Discussion. This study demonstrates rapid loss of CoCr material from wear in TKA, and reports absence of scratching and roughening of ceramic TKA femoral components in simulated wear. This observation suggests a mechanism for the lower polyethylene wear rate against ceramic femoral components, and suggests an advantage in avoiding metal sensitivity


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_IX | Pages 95 - 95
1 Mar 2012
Wilding CP Maruthainar K Malikian R Stammers J Blunn GW
Full Access

Purpose. To determine the effect that Titanium Nitride (TiN) coatings have on wear rates of ultra high molecular weight polyethylene (UHMWPE). Background. Ceramic coatings have been shown to confer advantageous countersurface scratch resistance in knee arthroplasty. This may reduce UHMWPE wear rates and revision rates. Dermal hypersensitivity is a common problem with metals; TiN, a ceramic surface, has been used to prevent it. There is little data in the literature regarding the effect of TiN on UHMWPE. Materials and methods. A six station pin-on-plate testing machine cycled three cobalt chrome pins and three TiN-coated cobalt chrome pins against six gamma-irradiated UHMWPE plates at 1 Hz at 20°C. A lubricating solution of 30% bovine calf serum, 1% sodium azide and deionised water was used. Three gamma-irradiated UHMWPE plates served as soak controls. Average surface roughness of the pins was measured by surface profilometry. Scanning electron micrographs were taken after 0, 10, 100, 1000, 10000, 100000 and 1000000 cycles, with plate mass measured at 0, 10000, 100000 and 1000000 cycles. Results. There was a significant effect of cycles upon surface roughness, with increased number of cycles leading to an increase in surface roughness (p<0.01). No significant main effect was found of coating group upon average surface roughness of pins (p>0.07). There was no observed significant main effect of increasing number of cycles upon plate mass (p>0.05) or of pin group upon plate mass (p>0.05). Conclusion. A significant effect was shown of cycles upon surface roughness. However, a lack of other significant findings indicates additional research is required to fully determine titanium nitride's potential in knee arthroplasty


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_9 | Pages 1 - 1
1 Oct 2020
Springer B Haddad FS
Full Access

The COVID-19 pandemic has led to unprecedented times worldwide. From lockdowns to masks now being part of our everyday routine, to the halting of elective surgeries, the virus has touched everyone and every part of our personal and professional lives. Perhaps, now more than ever, our ability to adapt, change and persevere is critical to our survival. This year's closed meeting of The Knee Society demonstrated exactly those characteristics. When it became evident that an in-person meeting would not be feasible, The Knee Society leadership, under the direction of President John Callaghan, MD and Program Chair Craig Della Valle, MD created a unique and engaging meeting held on September 10–12, 2020. Special recognition should be given to Olga Foley and Cynthia Garcia at The Knee Society for their flexibility and creativeness in putting together a world-class flawless virtual program. The Bone & Joint Journal is very pleased to partner with The Knee Society to once again publish the proceedings of the closed meeting of the Knee Society. The Knee Society is a United States based society of highly selected members who have shown leadership in education and research in knee surgery. It invites up to 15% international members; this includes some of the key opinion leaders in knee surgery from outside the USA. Each year, the top research papers from The Knee Society meeting will be published and made available to the wider orthopaedic community in The Bone & Joint Journal. The first such proceedings were published in BJJ in 2019. International dissemination should help to fulfil the mission and vision of the Knee Society of advancing the care of patients with knee disorders through leadership, education and research. The quality of dissemination that The Bone & Joint Journal provides should enhance the profile of this work and allow a larger body of surgeons, associated healthcare professionals and patients to benefit from the expertise of the members of The Knee Society. The meeting is one of the highlights of the annual academic calendar for knee surgeons. With nearly every member in attendance virtually throughout the 3 days, the top research papers from the membership were presented and discussed in a virtual format that allowed for lively interaction and discussion. There are 75 abstracts presented. More selective proceedings with full papers will be available after a robust peer review process in 2021, both online and in The Bone & Joint Journal. The meeting commenced with the first group of scientific papers focused on Periprosthetic Joint Infection. Dr Berry and colleagues from the Mayo Clinic further help to clarify the issue of serology and aspirate results to diagnose TKA PJI in the acute postoperative setting. 177 TKA's had an aspiration within 12 weeks and 22 were proven to have PJI. Their results demonstrated that acute PJI after TKA should be suspected within 6 weeks if CRP is ≥81 mg/L, synovial WBCs are ≥8500 cells/μL, and/or synovial neutrophils≥86%. Between 6– 12 weeks, concerning thresholds include a CRP ≥ 32 mg/L, synovial WBC ≥7450, and synovial neutrophils ≥ 84%. While historically the results of a DAIR procedure for PJI have been variable, Tom Fehring's study showed promise with the local delivery of vancomycin through the Intraosseous route improved early results. New member Simon Young contrasted the efficacy of the DAIR procedure when comparing early infections to late acute hematogenous PJI. DAIR failed in 63% of late hematogenous PJIs (implant age>1 year) compared to 36% of early (<1year) PJIs. Dr Masri demonstrated in a small group of patients that those with well-functioning articulating spacers can retain their spacers for over 12 months with no difference in infection from those that had a formal two stage exchange. The mental toll of PJI was demonstrated in a longitudinal study by Doug Dennis, where patient being treated with 2 stage exchange had 4x higher rates of depression compared to patient undergoing aseptic revision. The second session focused on both postoperative issues with regards to anticoagulation and manipulation. Steven Haas demonstrated high complication rates with utilization of anticoagulation for treatment of postoperative pulmonary embolism with modern therapeutic anticoagulation (warfarin, enoxaparin, Xa inhibitors) with the Xa inhibitors demonstrating lower complication rates. Two papers focused on the topic of manipulation. Mark Pagnano presented data on timing of manipulation under anesthesia up to even past 12 months. While gains were modest, a subset of patients did achieve substantial gains in ROM > 20degrees even after 3 months post op. Dr Westrich's study demonstrated no difference in MUA outcomes with either IV sedation or neuraxial anesthesia although the length of stay was shorter in the IV sedation group. Several studies in Session II focused on kinematics and femoral component position. Dr Li's in vivo kinematic study during weightbearing flexion and gait demonstrated that several knees rotated with a lateral pivot motion and not all knees can be described with a single motion character. Dr Mayman and his group utilized a computational knee model to demonstrate that additional distal femoral resection results in increasing levels of mid -flexion instability and cautioned against the use of additional bony resection as the first line for flexion contractures. Using computer navigation, Dr Huddleston's study nicely outlined the variability in femoral component rotation to achieve a rectangular flexion gap utilizing a gap balanced method. The third session opened the meeting on Friday morning. The focus was on unicompartmental knee arthroplasty and the increasing utilization of robotic assisted total knee arthroplasty. David Murray showed using registry data that for patient with higher comorbidities (ASA >3), UKA was safer and more cost effective than TKA while Dr Della Valle's group demonstrated overall lower average healthcare costs in UKA patients compared to TKA in the first 10 years after surgery. Dr Geller assessed UKA survivorship among 3 international registries. While survivorship varied by nation and designs, certain designs consistently had better overall performance. Dr Nunley and his group showed robotic navigation UKA significantly reduced outliers in alignment and overhang compared to manual UKA. Dr Catani's data demonstrated that full thickness cartilage loss should still be considered a requirement for UKA success even with robotic assistance. Despite a high dislocation rate of 4%, Mr Dodd demonstrated high survivorship for lateral UKA despite historical contraindications. The growing evidence for robotics TKA was demonstrated in two studies. Professor Haddad showed less soft tissue injury, reduced bone trauma and improved accuracy or rTKA compared to manual TKA while Dr Gustke single surgeon study showed his rTKA had improved forgotten joint scores and less ligament releasing required for balancing. Despite these finding, Dr Lee's study demonstrated that a robotic TKA could not guarantee excellent pain relief and other factors such a patient expectations and psychological factors play a role. Our fourth session was devoted to machine learning and smart tools and modeling. Dr Meneghini used machine learning algorithms to identify optimal alignment outcomes that correlated with patient outcomes. Several parameters such as native tibial slope, femoral sagittal position and coronal limb alignment correlated with outcomes. Along the same lines, Bozic and coauthors demonstrated that using AI algorithms incorporated with PROM's improved levels of shared decision making and patient satisfaction. Dr Lombardi demonstrated that a mobile patient engagement platform that provided smart phone-based exercise and education was comparable to traditional methods. Dr Mahfouz demonstrated the accuracy of using ultrasound to produce 3D models of the bone compared to conventional CT based strategies and Dr Mahoney showed the valued of a preop 3D model in reproducing more normal knee kinematics. The last two talks of the session focused on some of the positives of the COVID-19 pandemic, namely the embracing of telemedicine by patients and surgeons as demonstrated by Dr Slover and the increasing and far reaching educational opportunities made available to residents and fellows during the pandemic. Session five focused on risk stratification and optimization prior to TKA. Dr O'Connor demonstrated that that the implementation of an optimization program preoperatively reduced length of stay and ED visits, and Charles Nelson's study showed that risk stratification tool can lower complication rates in obese patients undergoing TKA comparable to those that are nonobese. Dr Markel's study demonstrated that those who have preoperative depression and anxiety are at higher risk of complications and readmissions after surgery and these issues should be addressed preoperatively. Interestingly, a study by Dr Callaghan demonstrated that care improvement pathways have not lowered the gap in complications for morbidly obese patients undergoing TKA, Dr Barsoum argued that the overall complication rates were low and this patient cohort had significant gains in PROMS after TKA that would not be experienced if arbitrary cutoff for limited surgery were established. The final session on Friday, Session six, had several well done and interesting studies. There continues to be mounting evidence that liposomal bupivacaine has little effect on managing post-operative pain to warrant its increased use. Bill Macaulay and colleagues showed no change in pain scores, opioid consumption and functional scores when liposomal bupivacaine was discontinued at a large academic medical center. Dr Bugbee importantly demonstrated that a supervised ambulation program reduced falls in the early postoperative period. Several paper on healthcare economics were presented. Rich Iorio showed that stratifying complexity of total joint cases between hospitals with a system can be efficient and cost savings while Dr Jiranek demonstrated in his study that complex TKAs can be identified preoperatively and are associated with prolonged operative time and cost of care and consideration should be given in future reimbursement models to a complexity modifier. Dr Springer, in their evaluation of Medicare bundled payment models, demonstrated that providers and hospitals in historical bundled models that became efficient were penalized in the new model, forcing many groups to drop out and return to a fee for service model. Ron Delanois important work showed that social determinants can have a major negative impact on outcomes following TKA. Our final day on Saturday opened with Session seven, and several interesting paper on metal ions/debris in TKA. Dr Whitesides simulator study showed the absence of scratches and material loss in a ceramic TKA compared with Co-Cr TKA and suggested an advantage to this material in patients with metal sensitivity. Conversely, in a histological study of failed TKA, perivascular lymphocytic infiltration was not associated with worse clinical outcomes or differences in revision in a series of 617 aseptic revisions, 19% of which had PVLI found on histology. The Mayo group and Dr Trousdale however, noted that serum metal ion levels can be helpful in identifying implant failure in a group of revision TKAs, especially those with metallic junctions. Dr Dalury demonstrated nicely that use of maximally conforming inserts did not have a negative effect on implant loosening in a series of 76 revision TKA's at an average follow up of 7 years, while Kevin Garvin and his group showed no difference in end of stem pain between cemented and cementless stems in revision TKA. The final two studies in the session by Bolognesi and Peters respectively showed that metaphyseal cones continue to demonstrate excelled survivorship in rTKA setting despite extensive bone loss. Session eight was highlighted by a large series of revision reported by new member Dr Schwarzkopf, who showed that revision TKA done by high volume surgeons demonstrated better outcomes and lower revision rates compared to surgeon who did less than 18 rTKA's per year. Dr Maniar importantly showed that preoperatively, patients with high activity level and low pain and indicated by a high preop forgotten joint score did poorly following TKA while David Ayers nicely demonstrated that KOOS scores that assess specific postoperative outcomes can predict patient dissatisfaction after TKA. The final paper in this session by Max Courtney showed that the majority of surgical cancellations are due to medical issues, yet a minority of these undergo any intervention specifically for that condition, but they resulted in a delay of 5 months. The first two studies of Session nine focused on polyethylene thickness. Dr Backstein demonstrated no difference in KSS scores, change in ROM and aseptic revision rates based on polyethylene thickness in a series of 195 TKA's. An interesting lab study by Dr Tim Wright showed a surprising consistency in liner thickness choice among varying levels of surgeon experience that did not correlate with applied forces or gap stability estimates. Two studies looked specifically at the issue of tibial loosening and implant design. Nam and colleagues were not able to demonstrate concerning findings for increasing tibial loosening in a tibial baseplate with a shortened tibial keel at short term follow up, while Lachiewicz demonstrated a 19% revision or revision pending rate in 223 cemented fixed bearing ATTUNE TKA at a mean of 30 months. Our final session of the meeting, began with encouraging news, that despite only currently capturing about 40% of TJA's done in the US, the American Joint Replacement Registry data is representative of data in other representative US databases. An interesting study presented by Robert Barrack looked at bone remodeling in the proximal tibia after cemented and cementless TKA of two different designs. No significant difference was noted among the groups with the exception of the cemented thicker cobalt chrome tray which demonstrated significantly more bone mineral density loss. Along the same lines, a study out of Dr Bostrom's lab demonstrated treatment of a murine tibial model with iPTH prevents fibrous tissue formation and enhances bone formation in cementless implants. New Member Jamie Howard showed no difference in implant migration and kinematics of a single radius cementless design using either a measured resection or gap balancing technique and Dr Cushner show no difference in blood loss with cemented or cementless TKA with the use of TKA. The final two studies looked at staging and bilateral TKA's. Peter Sharkey showed that simultaneous TKA's were associated with higher complication compared to staged TKA and that staged TKA with less than a 90-day interval was not associated with higher risk. However, Mark Figgie showed that patients undergoing simultaneous TKA compared to staged TKA, missed 17 fewer days of work. In spite of the virtual nature of the meeting, there were some outstanding scientific interactions and the material presented will continue to generate debate and to guide the direction of knee arthroplasty as we move forwards


The Bone & Joint Journal
Vol. 103-B, Issue 1 | Pages 98 - 104
1 Jan 2021
van Ooij B Sierevelt IN van der Vis HM Hoornenborg D Haverkamp D

Aims

For many designs of total knee arthroplasty (TKA) it remains unclear whether cemented or uncemented fixation provides optimal long-term survival. The main limitation in most studies is a retrospective or non-comparative study design. The same is true for comparative trials looking only at the survival rate as extensive sample sizes are needed to detect true differences in fixation and durability. Studies using radiostereometric analysis (RSA) techniques have shown to be highly predictive in detecting late occurring aseptic loosening at an early stage. To investigate the difference in predicted long-term survival between cemented, uncemented, and hybrid fixation of TKA, we performed a randomized controlled trial using RSA.

Methods

A total of 105 patients were randomized into three groups (cemented, uncemented, and hybrid fixation of the ACS Mobile Bearing (ACS MB) knee system, implantcast). RSA examinations were performed on the first day after surgery and at scheduled follow-up visits at three months, six months, one year, and two years postoperatively. Patient-reported outcome measures (PROMs) were obtained preoperatively and after two years follow-up. Patients and follow-up investigators were blinded for the result of randomization.


The Bone & Joint Journal
Vol. 102-B, Issue 6 Supple A | Pages 138 - 144
1 Jun 2020
Heckmann ND Nahhas CR Yang J Della Valle CJ Yi PH Culvern CN Gerlinger TL Nam D

Aims

In patients with a “dry” aspiration during the investigation of prosthetic joint infection (PJI), saline lavage is commonly used to obtain a sample for analysis. The aim of this study was to investigate prospectively the impact of saline lavage on synovial fluid analysis in revision arthroplasty.

Methods

Patients undergoing revision hip (THA) or knee arthroplasty (TKA) for any septic or aseptic indication were enrolled. Intraoperatively, prior to arthrotomy, the maximum amount of fluid possible was aspirated to simulate a dry tap (pre-lavage) followed by the injection with 20 ml of normal saline and re-aspiration (post-lavage). Pre- and post-lavage synovial white blood cell (WBC) count, percent polymorphonuclear cells (%PMN), and cultures were compared.


The Bone & Joint Journal
Vol. 101-B, Issue 2 | Pages 227 - 232
1 Feb 2019
Walker T Rutkowski L Innmann M Panzram B Herre J Gotterbarm T Aldinger PR Merle C

Aims

The treatment of patients with allergies to metal in total joint arthroplasty is an ongoing debate. Possibilities include the use of hypoallergenic prostheses, as well as the use of standard cobalt-chromium (CoCr) alloy. This non-designer study was performed to evaluate the clinical outcome and survival rates of unicondylar knee arthroplasty (UKA) using a standard CoCr alloy in patients reporting signs of a hypersensitivity to metal.

Patients and Methods

A consecutive series of patients suitable for UKA were screened for symptoms of metal hypersensitivity by use of a questionnaire. A total of 82 patients out of 1737 patients suitable for medial UKA reporting cutaneous metal hypersensitivity to cobalt, chromium, or nickel were included into this study and prospectively evaluated to determine the functional outcome, possible signs of hypersensitivity, and short-term survivorship at a minimum follow-up of 1.5 years.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 2 | Pages 205 - 209
1 Feb 2011
Willis-Owen CA Keene GC Oakeshott RD

Metallosis is a rare cause of failure after total knee replacement and has only previously been reported when there has been abnormal metal-on-metal contact. We describe 14 patients (15 knees) whose total knee replacement required revision for a new type of early failure caused by extensive metallosis. A modification of a cementless rotating platform implant, which had previously had excellent long-term survival, had been used in each case. The change was in the form of a new porous-beaded surface on the femoral component to induce cementless fixation, which had been used successfully in the fixation of acetabular and tibial components. This modification appeared to have resulted in metallosis due to abrasive two-body wear. The component has subsequently been recalled and is no longer in use. The presentation, investigation, and findings at revision are described and a possible aetiology and its implications are discussed.


The Bone & Joint Journal
Vol. 96-B, Issue 2 | Pages 217 - 223
1 Feb 2014
Namba RS Inacio MCS Cafri G

The outcome of total knee replacement (TKR) using components designed to increase the range of flexion is not fully understood. The short- to mid-term risk of aseptic revision in high flexion TKR was evaluated. The endpoint of the study was aseptic revision and the following variables were investigated: implant design (high flexion vs non-high flexion), the thickness of the tibial insert (≤ 14 mm vs > 14 mm), cruciate ligament (posterior stabilised (PS) vs cruciate retaining), mobility (fixed vs rotating), and the manufacturer (Zimmer, Smith & Nephew and DePuy). Covariates included patient, implant, surgeon and hospital factors. Marginal Cox proportional hazard models were used.

In a cohort of 64 000 TKRs, high flexion components were used in 8035 (12.5%). The high flexion knees with tibial liners of thickness > 14 mm had a density of revision of 1.45/100 years of observation, compared with 0.37/100 in non-high flexion TKR with liners ≤ 14 mm thick. Relative to a standard fixed PS TKR, the NexGen (Zimmer, Warsaw, Indiana) Gender Specific Female high flexion fixed PS TKR had an increased risk of revision (hazard ratio (HR) 2.27 (95% confidence interval (CI) 1.48 to 3.50)), an effect that was magnified when a thicker tibial insert was used (HR 8.10 (95% CI 4.41 to 14.89)).

Surgeons should be cautious when choosing high flexion TKRs, particularly when thicker tibial liners might be required.

Cite this article: Bone Joint J 2014;96-B:217–23.


The Bone & Joint Journal
Vol. 95-B, Issue 3 | Pages 301 - 304
1 Mar 2013
Brennan SA Devitt BM O’Neill CJ Nicholson P

Focal femoral inlay resurfacing has been developed for the treatment of full-thickness chondral defects of the knee. This technique involves implanting a defect-sized metallic or ceramic cap that is anchored to the subchondral bone through a screw or pin. The use of these experimental caps has been advocated in middle-aged patients who have failed non-operative methods or biological repair techniques and are deemed unsuitable for conventional arthroplasty because of their age. This paper outlines the implant design, surgical technique and biomechanical principles underlying their use. Outcomes following implantation in both animal and human studies are also reviewed.

Cite this article: Bone Joint J 2013;95-B:301–4.


Bone & Joint Research
Vol. 1, Issue 11 | Pages 281 - 288
1 Nov 2012
Conlisk N Gray H Pankaj P Howie CR

Objectives

Orthopaedic surgeons use stems in revision knee surgery to obtain stability when metaphyseal bone is missing. No consensus exists regarding stem size or method of fixation. This in vitro study investigated the influence of stem length and method of fixation on the pattern and level of relative motion at the bone–implant interface at a range of functional flexion angles.

Methods

A custom test rig using differential variable reluctance transducers (DVRTs) was developed to record all translational and rotational motions at the bone–implant interface. Composite femurs were used. These were secured to permit variation in flexion angle from 0° to 90°. Cyclic loads were applied through a tibial component based on three peaks corresponding to 0°, 10° and 20° flexion from a normal walking cycle. Three different femoral components were investigated in this study for cementless and cemented interface conditions.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 9 | Pages 1221 - 1227
1 Sep 2012
Kim Y Park J Kim J

Despite many claims of good wear properties following total knee replacement (TKR) with an oxidised zirconium (OxZr) femoral component, there are conflicting clinical results. We hypothesised that there would be no difference in either the mid-term clinical and radiological outcomes or the characteristics of the polyethylene wear particles (weight, size and shape) in patients using an OxZr or cobalt-chrome (CoCr) femoral component. In all 331 patients underwent bilateral TKR, receiving an OxZr femoral component in one knee and a CoCr femoral component in the other. The mean follow-up was 7.5 years (6 to 8). Following aspiration, polyethylene wear particles were analysed using thermogravimetric methods and scanning electron microscopy. At the most recent follow-up, the mean Knee Society score, Western Ontario and McMaster Universities Osteoarthritis Index score, range of movement and satisfaction score were not significantly different in the two groups. The mean weight, size, aspect ratio and roundness of the aspirated wear particles were similar for each femoral component. Survivorship of the femoral, tibial and patellar components was 100% in both groups.

In the absence of evidence of an advantage in the medium term we cannot justify the additional expense of an OxZr femoral component.