The purposes of this study were to review retrospectively the 25-year survival of cemented and
Introduction. Long term results of Total Hip Arthroplasty (THA) are affected by wear of articulation. Ceramic on ceramic articulation have been used especially for young patients because of its low wear and bio-inert property. However, because of its hardness, it is concerned that ceramic fracture, chipping, or squeaking might happen with ceramic on ceramic articulation. Objective. The purpose of this study was to investigate over 10-years clinical and radiographic results of ceramic bearing
Introduction:. The outcome of previous cemented total hip arthroplasty has been reported to be inferior in renal transplant patients because of poor bone stock resulting from long-term steroid use. Moreover, as renal transplant patients remain on immunosuppressant therapy for life, higher levels of overall morbidity must be considered. We evaluated the mid-term results of
Introduction. The success of
Total hip arthroplasty (THA) is frequently performed as a salvage procedure for the acetabular fracture when posttraumatic osteoarthritis, posttraumatic avascular necrosis, or fixation failure with subluxation develop. Special considerations for this situation include previous surgical exposure with dense scar tissue, the type and location of implants, the location and amount of heterotopic ossification, indolent infection, previous sciatic nerve palsy, and the pathoanatomy of existing acetabular defect. These factors can influence the choice of surgical exposure and the reconstructive method. The outcomes of THA after acetabular fracture are generally less favorable than those of the nontraumatic degenerative arthritis. Reason for this high failure is the low mean age and the high activity level of the patient. Other important reasons for failure include the problem of acetabular bone deficiency and compromised bone quality. We evaluated the results of
Although there are several reports of excellent long-term survival after cemented total hip arthroplasty (THA), cemented acetabular components are prone to become loose when compared with femoral components. On the other hand, the survival of cementless acetabular components has been reported to be equal or better than cemented ones and the use of cementless acetabular components is increasing. However, most of the reports on survival after THA are for patients with primary hip osteoarthritis (OA) and there is no report of 20-year survival of
Introduction. Preoperative planning is an essential procedure for successful total hip arthroplasty. Many studies reported lower accuracy of two-dimensional analogue or digital templating for developmentally dysplastic hips (DDH). There have been few studies regarding the utility of three-dimensional (3D) templating for DDH. The aim of the present study is to assess the accuracy and reliability of 3D templating of
Background. Nutrient arteries appear as radiolucent lines (Fig. 1) on account of their topography and may erroneously suggest fracture lines. Question/purpose. (1) How frequently the nutrient artery canals of the femur are seen after
Total hip arthroplasty (THA) is associated with high intraoperative and postoperative blood loss. Antifibrinolytic drugs have been used to minimize the potential risks of bleeding and blood transfusion. Studies on the effect of tranexamic acid on decreasing blood loss in THA have revealed interesting results, but most have focused on cemented THA. Yet its benefits in THA, especially in
Background. Although thigh pain is an annoying problem after total hip arthroplasty (THA), little information has been known about its natural course. Methods. To determine the frequency, time of onset, and duration of thigh pain after
The study aims to compare the short-term results of cemented and
‘Getting It Right First Time’ guidance recommends the universal use of cemented prostheses in patients aged over 65 within the UK. This cut off has since been raised to 70. The report claims that the increased cost of uncemented technology is not justifiable in terms of patient outcomes. Our aim was to evaluate any disparity between patients across these age thresholds, in terms of functional outcomes, complication and costs following elective uncemented THR. We utilised a single surgeon prospectively updated database, to compare functional outcome of patients aged over and under 65 and again at 70 following elective uncemented THR. We measured functional outcome using Oxford Hip Score (OHS). Patients were followed routinely for up to 2 years and subsequently up to 6 years. Patient ages ranged from 23–89. Over 97% of patients reported an improvement in hip function, with an average increase of 24.1 in OHS. There was no statistical significance between patient age and functional hip outcome, p=0.108 with a cut off at 65 and p=0229 at 70. 1.1% of under 65s required revision surgery, compared to 2.3% of over 65s. 1.4% of patients under 70 required revision surgery, compared to 2.5% in those above. The most common reason for revision surgery was debridement, antibiotics and implant retention. Patients under 65 had a 1.4% chance of experiencing a fracture or dislocation, compared to 2.5% of patients over 65. 2.0% of patients under 70 experienced a fracture or dislocation, in comparison to 2.2% in those over 70. There was 1 recorded mortality, a patient aged over 70. Cost analysis is challenging accounting for all variables between techniques. Cementing invariably requires additional operating time and diminished theatre efficiency, with direct cost estimated at £364 in theatre running fees per case. Within the series, uncemented THRs was found to be a safe and efficacious procedure irrespective of age. Functional hip outcome was not correlated to patient age, conflicting with GIRFT recommendations. The extra duration of cemented surgery may equilibrate the financial disparity of uncemented practice.
Background. Polyethylene wear in both cemented and
Femoral stem design affects periprosthetic bone mineral density (BMD), which may impact long term survival of cementless implants in total hip arthroplasty (THA). The aim of this study was to examine proximal femoral BMD in three morphologically different uncemented femoral stems designs to investigate whether one particular design resulted in improved preservation of BMDMethods: 119 patients were randomised to receive either a proximally coated dual taper wedge stem, a proximally coated anatomic stem or a fully coated collarless triple tapered stem. All surgeries were performed via the posterior approach with mobilization on the day of surgery. Dual energy x-ray absorptiometry scans (Lunar iDXA, GE Healthcare, Madison, WI) assessed BMD across the seven Gruen zones pre-operatively, and post-operatively at 6-weeks, 1-year, and 2-years and compared to the unoperated contralateral femur as a control. Patient reported outcome measures of pain, function and health were also included at these corresponding follow-ups. BMD increased in zones one (2.5%), two (17.1%), three (13.0%), five (10%) and six (17.9%) for all stems. Greater preservation of BMD was measured on the lateral cortex (zone 2) for both the dual taper wedge and anatomic stems (p = 0.019). The dual taper wedge stem also demonstrated preservation of BMD in the medial calcar (zone 7) whilst the anatomic and triple taper stem declined in this region, however this was not statistically significant (p = 0.059). BMD decreased on average by 2.1% inthe mid-diaphysis region, distal to the stem tip (zone 4) for all implants. All stems performed equivalently at final follow-up in all patient reported outcome measures. This study demonstrated maintenance of femoral BMD in three different cementless femoral stem designs, with all achieving excellent improvements in patient reported outcomes. There was no significant stress shielding observed, however longer follow-up is required to elucidate the impact of this finding on implant survivorship.
Introduction. The optimal bearing for hip arthroplasty is still a matter of debate. in younger and more active patients ceramic-on-polyethylene (CoP) bearings are frequently chosen over metal-on-polyethylene (MoP) bearings to reduce wear and increase biocompatibility. However, the fracture risk of ceramic heads is higher than that of metal heads. This can cause serious issue, as ceramic fractures pose a serious complication often necessitating major revision surgery – a complication more frequently seen in ceramic-on-ceramic bearings. To date, there are no long-term data (> 20 years of follow-up) reporting fracture rates of the ceramic femoral heads in CoP bearings. Patients and Methods. We retrospectively evaluated the clinical and radiographic results of 348 cementless THAs treated with 2nd generation Biolox® Al2O3 Ceramic-on-Polyethylene (CoP) bearings, which had been consecutively implanted between January 1985 and December 1989. At implantation the mean patient age was 57 years. The cohort was subsequently followed for a minimum of 20 years. At the final follow-up 111 patients had died, and 5 were lost to follow-up (Fig. 1). A Kaplan-Meier survivorship analysis was used to estimate the cumulative incidence of ceramic head fractures over the long-term. Results. (Figs. 2, 3):. After 22-years the cumulative incidence of ceramic head fracture was estimated at 0.3% (95%-CI, 0–2.4%; 38 hips at risk). No impending failures could be noted on radiographic analysis at final follow-up. Discussion. The fracture rate of second-generation ceramic heads using a CoP articulation remains very low into the third decade after
Introduction and Aims. The 21. st. Century has seen ceramic bearings become an increasingly popular choice in total hip arthroplasty due to their high wear resistance and inert wear debris without osteolysis promising a long term bearing solution. Early ceramic bearings were hindered by fracture but improved manufacturing processes and materials subsequently produced stronger ceramics. These third generation ceramics showed greatly reduced fracture rates but there is limited evidence in the literature reporting their long term survival and wear characteristics. The purpose of this study was to determine osteolysis and survival rates of Alumina ceramic bearings in
A prospective, randomized, double-blind study was done on 50 patients undergoing primary
Background. Subtrochanteric femoral shortening and corrective osteotomy are considered to be an integral part of total hip arthroplasty for a completely dislocated hip or severe deformity of the proximal femur. A number of alternative femoral osteotomy techniques, transverse, oblique, step-cut, and V-shaped, have been described. Becker and Gustilo reported the “double-chevron subtrochanteric shortening derotational femoral osteotomy,” which is reasonable in that the osteotomy site is torsionally more stable and can be stabilized with a shorter stem. We have simplified this procedure, and performed it without a trochanteric osteotomy. We describe a simplified double-chevron osteotomy and provide the clinical results from a series of 22 successful procedures. Methods. In this series, we performed 22
A prospective, randomized, double-blind study was done on 50 patients undergoing primary
Introduction:. Demand for total hip arthroplasty (THA) continues to rise and as such there is a concurrent presumed increase in the incidence of periprosthetic femoral fractures. Several studies have previously demonstrated differences in fixation technique and biomechanical advantages of various cerclage constructs in fixation of femoral periprosthetic fractures. The purpose of this study is to determine the most effective combination of cerclage materials and technique in fixation of of periprosthetic fractures during