Advertisement for orthosearch.org.uk
Results 1 - 7 of 7
Results per page:
The Bone & Joint Journal
Vol. 104-B, Issue 4 | Pages 472 - 478
1 Apr 2022
Maccario C Paoli T Romano F D’Ambrosi R Indino C Federico UG

Aims

This study reports updates the previously published two-year clinical, functional, and radiological results of a group of patients who underwent transfibular total ankle arthroplasty (TAA), with follow-up extended to a minimum of five years.

Methods

We prospectively evaluated 89 patients who underwent transfibular TAA for end-stage osteoarthritis. Patients’ clinical and radiological examinations were collected pre- and postoperatively at six months and then annually for up to five years of follow-up. Three patients were lost at the final follow-up with a total of 86 patients at the final follow-up.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_21 | Pages 26 - 26
1 Apr 2013
Ahluwalia R Cooke P Rogers M Sharp R
Full Access

Introduction. Ankle replacement is now common in the UK. In a tertiary referral NHS practice, between 1997–2011 we implanted two types of cementless mobile bearing total ankle replacements (TAR). Methods. We reviewed our operative database and electronic patient records and confirmed the number of prosthesis with our theatre records. All case notes and radiographs were reviewed. Failure was taken as revision, and patients were censored due to death or loss to follow-up. The survivorship was calculated using a life table (the Kaplan-Meier method), with 95% confidence intervals. Results. We found a total of 358 NHS patients had a TAR from Jan 1997 to April 2012 total ankle replacements; the mean follow up was 76 months. The principle indications for surgery included primary OA (n=146) and inflammatory arthritis in (n=79). Overall survival was 90.9% (94–84) at 10 years. A complication requiring revision developed in 42 ankles and 36 were revised or fused. Thirty-two TAR's underwent further hind foot fusions which were not attributed as a failure of the prosthesis. We arthroscoped 6 TAR's for hetrotrophic calcification. When we separated the implants we found the STAR (implanted from 1997–2004) had a 5-year survival of 95.2% (98–91) and the Mobility (implanted from 2004–11) of 92.6% (96–88). We found early failures (within 2 years of implantation) were higher within 2 years of introduction of TAR and on changing our prosthesis. Conclusion. In a study of TAR undertaken at one centre principally by an experienced surgeon and team, we have shown a learning curve. Cementless mobile bearing total ankle replacements (TAR) conducted on a routine basis with careful patient selection has a 90.9% survivorship over a 10-year period. The difference in survival for two implants is not statistically significant


The Bone & Joint Journal
Vol. 103-B, Issue 4 | Pages 696 - 703
1 Apr 2021
Clough TM Ring J

Aims

We report the medium-term outcomes of a consecutive series of 118 Zenith total ankle arthroplasties (TAAs) from a single, non-designer centre.

Methods

Between December 2010 and May 2016, 118 consecutive Zenith prostheses were implanted in 114 patients. Demographic, clinical, and patient-reported outcome measures (PROMs) data were collected. The endpoint of the study was failure of the implant requiring revision of one or all of the components. Kaplan-Meier survival curves were generated with 95% confidence intervals (CIs) and the rate of failure calculated for each year.


The Bone & Joint Journal
Vol. 102-B, Issue 12 | Pages 1689 - 1696
1 Dec 2020
Halai MM Pinsker E Mann MA Daniels TR

Aims

Preoperative talar valgus deformity ≥ 15° is considered a contraindication for total ankle arthroplasty (TAA). We compared operative procedures and clinical outcomes of TAA in patients with talar valgus deformity ≥ 15° and < 15°.

Methods

A matched cohort of patients similar for demographics and components used but differing in preoperative coronal-plane tibiotalar valgus deformity ≥ 15° (valgus, n = 50; 52% male, mean age 65.8 years (SD 10.3), mean body mass index (BMI) 29.4 (SD 5.2)) or < 15° (control, n = 50; 58% male, mean age 65.6 years (SD 9.8), mean BMI 28.7 (SD 4.2)), underwent TAA by one surgeon. Preoperative and postoperative radiographs, Ankle Osteoarthritis Scale (AOS) pain and disability and 36-item Short Form Health Survey (SF-36) version 2 scores were collected prospectively. Ancillary procedures, secondary procedures, and complications were recorded.


Orthopaedic Proceedings
Vol. 97-B, Issue SUPP_14 | Pages 15 - 15
1 Dec 2015
Walter R Harries W Hepple S Winson I
Full Access

The Zenith. TM. total ankle replacement (Corin, Cirencester) is a mobile-bearing implant based on the Buechal Pappas design. Key features are the simple fully-jigged instrumentation aiming to improve accuracy and reproducibility of implant positioning, cementless calcium phosphate coated surfaces for improved early osseointegration, and titanium nitride-coated bearing surfaces to resist wear. We present early to mid-term survival data for 155 total ankle replacements implanted by three surgeons in our institute. Case records of all patients undergoing Zenith. TM. Total Ankle Replacement by three senior surgeons, including a member of the design team, between 2007 and 2014 were examined. Patients were examined clinically and radiographically annually after the early postoperative period. The primary outcome measure was implant survival. Secondary outcome measures included complication rates, parameters of radiographic alignment, and radiographic evidence of cysts and loosening. One hundred and fifty-five cases were performed for a mixture of primary pathologies, predominantly primary or posttraumatic arthrosis. Mean follow-up was 50 months. Implant survival was 99.0% at 3 years (n=103), 94.0% at 5 years (n=50), and 93.8% at 7 years (n=16). One patient was revised to arthrodesis for aseptic loosening, one arthrodesis was performed for periprosthetic infection with loosening, and one below-knee amputation was performed for chronic pain. Three cases underwent further surgery to address cysts, and 7 malleolar fractures were reported. Medial gutter pain was experienced by 9% of patients. Overall, our data show excellent early and mid-term survivorship for the Zenith. TM. Total Ankle Replacement. Simple fully-jigged instrumentation allows accurate and reproducible implant alignment


The Bone & Joint Journal
Vol. 101-B, Issue 6 | Pages 695 - 701
1 Jun 2019
Yang H Wang S Lee K

Aims

The purpose of this study was to determine the functional outcome and implant survivorship of mobile-bearing total ankle arthroplasty (TAA) performed by a single surgeon.

Patients and Methods

We reviewed 205 consecutive patients (210 ankles) who had undergone mobile-bearing TAA (205 patients) for osteoarthritis of the ankle between January 2005 and December 2015. Their mean follow-up was 6.4 years (2.0 to 13.4). Functional outcome was assessed using the Ankle Osteoarthritis Scale, American Orthopaedic Foot and Ankle Society (AOFAS) ankle-hindfoot score, 36-Item Short-Form Health Survey (SF-36) score, visual analogue scale, and range of movement. Implant survivorship and complications were also evaluated.


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 1 | Pages 61 - 65
1 Jan 2010
Morgan SS Brooke B Harris NJ

We present the outcomes in 38 consecutive patients who had total ankle replacement using the Ankle Evolution System with a minimum follow-up of four years. Pain and function were assessed using the American Orthopaedic Foot and Ankle Society (AOFAS) score and regular standardised anteroposterior and lateral weight-bearing radiographs were obtained. Patient satisfaction and complications were recorded and the survival of the implants was demonstrated by the Kaplan-Meier method.

The mean follow-up was for 57.8 months (48 to 80). The cumulative survival rate at six years was 94.7% (95% confidence interval 80.3 to 98.7). The mean total AOFAS score was 88.1 (53 to 100). The mean score for pain was 35.8 (20 to 40). Ten patients presented with edge-loading of whom nine had corrective surgery. Two ankles were revised, one to an arthrodesis and the other to replace the tibial component. Nine patients showed radiological evidence of osteolysis. They had minimal non-progressive symptoms and further surgery was not undertaken. Nevertheless, the concerns about osteolysis led to the implant being withdrawn by the manufacturer.

The medium-term results of the ankle evolution system ankle replacement are satisfactory with high patient satisfaction, but the rate of osteolysis is of some concern. The long-term benefit of this procedure has yet to be determined.