Aims. Autologous bone graft (ABG) is considered the ‘gold standard’ among graft materials for bone regeneration. However, complications including limited availability, donor site morbidity, and deterioration of regenerative capacity over time have been reported. P-15 is a synthetic peptide that mimics the cell binding domain of Type-I collagen. This peptide stimulates new bone formation by enhancing osteogenic cell attachment, proliferation, and differentiation. The objective of this study was to conduct a systematic literature review to determine the clinical efficacy and safety of P-15 peptide in bone regeneration throughout the skeletal system. Methods. PubMed, Embase, Web of Science, and Cochrane Library were searched for relevant articles on 13 May 2023. The systematic review was reported according to the PRISMA guidelines. Two reviewers independently screened and assessed the identified articles. Quality assessment was conducted using the methodological index for non-randomized studies and the risk of bias assessment tool for randomized controlled trials. Results. After screening, 28 articles were included and grouped by surgical indication, e.g. maxillofacial procedures (n = 18), spine (n = 9), and trauma (n = 1). Published results showed that P-15 peptide was effective in spinal fusion (n = 7) and maxillofacial (n = 11), with very few clinically relevant adverse events related to P-15 peptide. Conclusion. This systematic literature review concluded that moderate- (risk of bias, some concern: 50%) to high-quality (risk of bias, low: 46%) clinical evidence exists showing equivalent safety and efficacy in bone regeneration using a P-15 peptide enhanced
Aims. The purpose of this study was to assess the success rate and functional outcomes of
4 years of follow-up study on 27 patients who had biological reverse total shoulder replacement 12 patients who had Bio-RSA by using Tonier Aequalis reversed implants with
Aims. This study aims to report the outcomes in the treatment of unstable proximal third scaphoid nonunions with arthroscopic curettage, non-vascularized
Aims. Large acetabular bone defects encountered in revision total hip arthroplasty (THA) are challenging to restore. Metal constructs for structural support are combined with
Introduction. The purpose of this study was to analyse the efficacy and complications associated with the use of Calcium Sulphate synthetic
Objective. To determine differences in fracture stability and functional outcome between synthetic
Aims. The purpose of this systematic review was to determine the rates of union for vascularized versus non-vascularized grafting techniques in the operative management of scaphoid nonunion. Secondary aims were to determine the effect of the fixation techniques used, the source of grafting, as well as the influence of fracture location (proximal pole) and avascular necrosis (AVN). Methods. A search of PubMed, MEDLINE, and Embase was performed in June 2021 using the Preferred Reporting Items for Systematic Review and Meta-Analyses statement and registered using the PROSPERO International prospective register of systematic reviews. The primary outcome was union rate. Results. There were 78 studies that met the inclusion criteria with a total of 7,671 patients (87.8% male, 12.2% female). The mean age was 27.9 years (SD 3.8) and the mean follow-up was 30.9 months (SD 25.9). The mean union rate was 88.7% (95% confidence interval (CI) 85.0 to 92.5) for non-vascularized grafts versus 87.5% (95% CI 82.8 to 92.2) for vascularized grafts (p = 0.685). Pooled analysis of trial data alone found a mean union rate of 82.4% (95% CI 66.9% to 97.9%) for non-vascularized grafts and 89.4% (95% CI 84.1% to 94.7%) for vascularized grafts (p = 0.780). No significant difference was observed in union rates between any of the fixation techniques used in the studies (p = 0.502). Distal radius and iliac crest graft source had comparable mean union rates (86.9% (95% CI 83.1 to 90.7) vs 87.6% (95% CI 82.2 to 92.9); p = 0.841). Studies that excluded patients with both proximal pole fractures and AVN (n = 14) had a mean union rate of 96.5% (95% CI 94.2 to 98.9) that was significantly greater than the mean union rate of 86.8% (95% CI 83.2 to 90.4) observed in the remaining studies (p < 0.001). Conclusion. Current evidence suggests vascularized
Aim. This retrospective study evaluated the outcome of treatment for unhealed fracture-related infections (FRI). Methods. We identified a consecutive, single-centre cohort of patients having treatment for an FRI Consensus confirmed FRI. All fractures were unhealed at the time of treatment. Patients were followed up for at least one year. Successful outcome was a healed fracture without recurrent infection. Lack of union, persistent infection and/or unplanned reoperation defined failure. Results. Demographics: 183 patients (184 FRIs) with mean age 52.1 years (range 17-96) were treated and followed up for a mean of 2.8 years (range 1-9.4). Mean duration of FRI was 1.1 years with 65 (35.5 %) presenting within 6 months of injury. 118 patients had established infected non-union. FRI was most frequent in the tibia (74), femur (48) and humerus (24). 171 patients were BACH Complex. 75.5% of FRIs were culture positive, with Staph. aureus being the most frequent organism. Polymicrobial infection and Gram negative cultures were common (25.5% and 33.6%). Treatment: 98.3% of surgeries were performed in one stage with just 3 planned 2-stage procedures (2 endoprosthetic replacements and 1 free fibular flap). No
Problems associated with allograft are well known. The addition of hydroxyapatite (HA) to allograft has various mechanical advantages, especially within revision arthroplasty. The mixing of bone and HA results in mechanical properties different from the individual parts. However, at present the changes in material properties the mix have not been fully investigated and the optimum mixing ratio not characterized. A compressive uniaxial chamber was used to investigate the change in mechanical properties occurring with the addition of HA in varying proportions to morcellised
The continual cycle of bone formation and resorption
is carried out by osteoblasts, osteocytes, and osteoclasts under
the direction of the bone-signaling pathway. In certain situations
the host cycle of bone repair is insufficient and requires the assistance
of
Biphasic calcium phosphate (BCP) with a characteristic needle-shaped submicron surface topography (MagnetOs) has attracted much attention due to its unique bone-forming ability which is essential for repairing critical-size bone defects such as those found in the posterolateral spine. Previous in vitro and ex-vivo data performed by van Dijk LA and Yuan H demonstrated that these specific surface characteristics drive a favorable response from the innate immune system. This study aimed to evaluate and compare the in vivo performance of three commercially-available synthetic
Aims. Our objective was to conduct a systematic review and meta-analysis, to establish whether differences arise in clinical outcomes between autologous and synthetic
Aims. Bone stock restoration of acetabular bone defects using impaction
Bone defects require implantable graft substitutes, especially porous and biodegradable biomaterial for tissue regeneration. The aim of this study was to fabricate and assess a 3D-printed biodegradable hydroxyapatite/calcium carbonate scaffold for bone regeneration. Materials and methods:. A 3D-printed biodegradable biomaterial containing calcium phosphate and aragonite (calcium carbonate) was fabricated using a Bioplotter. The physicochemical properties of the material were characterised. The materials were assessed in vitro for cytotoxicity and ostegenic potential and in vivo in rat intercondylar Φ3mm bone defect model for 3 months and Φ5mm of mini pig femoral bone defects for 6 months. The results showed that the materials contained hydroxyapatite and calcium carbonate, with the compression strength of 2.49± 0.2 MPa, pore size of 300.00 ± 41mm, and porosity of 40.±3%. The hydroxyapatite/aragonite was not cytotoxic and it promoted osteogenic differentiation of human umbilical cord matrix mesenchymal stem cells in vitro. After implantation, the bone defects were healed in the treatment group whereas the defect of controlled group with gelatin sponge implantation remained non-union. hydroxyapatite/aragonite fully integrated with host bone tissue and bridged the defects in 2 months, and significant biodegradation was followed by host new bone formation. After implantation into Φ5mm femoral defects in mini pigs hydroxyapatite/aragonite were completed degraded in 6 months and fully replaced by host bone formation, which matched the healing and degradation of porcine allogenic
Aims. The aim of this study is to report the long-term outcomes of instrumented femoral revisions with impaction allograft
Cervical and lumbar spine fusion procedures are increasing every year. Nonetheless, these procedures are associated with high infection rates, resulting in additional cost burden. The conundrum of achieving efficient spinal fusions with minimum complications requires an ideal
Nonunion of the tibia associated with bone loss, previous infection, obliteration of the intramedullary canal or located in the distal metaphysis poses a challenge to the surgeon and significant morbidity to patients. We retrospectively reviewed the records of 24 patients who were treated by central
Post-traumatic osteonecrosis of the femoral head (ONFH) is a major complication of femoral neck fractures that require numerous solutions. The purpose of the current study is to investigate the effects of platelet-rich plasma (PRP) incorporated autologous granular
Purpose. The aim of this study was to assess the clinical and radiological result of the usage of chip