Advertisement for orthosearch.org.uk
Results 1 - 20 of 48
Results per page:
Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_13 | Pages 48 - 48
1 Nov 2021
Bundkirchen K Ye W Xu B Krettek C Relja B Neunaber C
Full Access

Introduction and Objective. In multiple trauma patients, as well as in the healing of isolated fractures (Fx) with heavy bleeding (trauma haemorrhage, TH), complications occur very often. This is particularly evident in elderly patients over 65 years of age. Since these accompanying circumstances strongly influence the clinical course of treatment, the influence of age on bone regeneration after femoral fracture and severe blood loss was investigated in this study. Materials and Methods. 12 young (17–26 weeks) and 12 old (64–72 weeks) male C57BL / 6J mice per group were examined. The fracture group Fx underwent an osteotomy after applying an external fixator. The THFx group also received blood pressure-controlled trauma hemorrhage (35 mmHg for 90 minutes) and reperfusion with Ringer's solution for 30 minutes. The Sham group received only the catheter and one external fixator. μCT scans of the femora were performed in vivo after 2 weeks and ex vivo after 3 weeks. Histological and biomechanical examinations were also carried out. The statistical significance was set at p ≤ 0.05. The non-normally distributed data were analyzed using the Mann-Whitney-U or Kruskal-Wallis test. Results. The histology showed less mineralized bone in the fracture gap in old animals of the Fx (25.41% [1.68%]) and THFx groups (25.50% [4.07%]) compared with the young ones (34.20% [6.36%], p = 0.003; 34.31% [5.12%], p=0.009). Moreover, a severe blood loss lead to more cartilage in both young (6.91% [5.08%]) and old animals (4.17% [1.42%]) compared to animals with only a fracture (2, 45% [1.04%], p=0.004; 2.95% [1.12%], p=0.032). In old animals (11.37 / nm. 2. [17.17 / nm. 2. ]) in contrast the young mice with an isolated fracture (33.6/nm. 2. [8.83/nm. 2. ]) fewer osteoclasts were present (p=0.009). Therefore, the severe blood loss further reduced the number of osteoclasts only in young animals (16.83/nm. 2. [6.07/nm. 2. ]) (p=0.004). In the in vivo μCT, after 2 weeks, a lower volume of bone, cortex and callus was found in old THFx animals (3.14 mm. 3. [0.64 mm. 3. ]); 1.01 mm. 3. [0.04 mm. 3. ]; 2.07 mm. 3. [0.57 mm. 3. ]) compared with the Fx animals (4.29 mm. 3. [0.74 mm. 3. ], p=0.008; 1.18 mm. 3. [0, 25 mm. 3. ], p=0.004; 3.02 mm. 3. [0.77 mm. 3. ], p=0.008) After 3 weeks, the ex vivo μCT scans also showed a reduced callus percentage in old THFx animals (61.18% [13.9 9%]), as well as a low number of trabeculae (1.81 mm. -1. [0.23 mm. -1. ]) compared to animals without blood loss (68.72% [15.71%], p = 0.030; 2.06mm. -1. [0.37mm. -1. ], p=0.041). In the biomechanical test, a reduced elasticity limit of the old THFx mice (7.75 N [3.33 N]) in contrast to the old Fx (10.24 N [3.32 N]) animals was shown (p=0.022). Conclusions. A severe blood loss has a higher negative effect on the healing, morphometry, and biomechanical properties of previously fractured femora in old compared to young individuals


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_11 | Pages 309 - 309
1 Jul 2014
Chen Y Tai B Nayak D Kumar N Goy R Wong H
Full Access

Summary. Our meta-analysis showed that pooled mean blood loss during spinal tumour surgeries was 2180 ml. Standardised methods of calculating and reporting intra-operative blood loss are needed as it would be beneficial in the pre-operative planning of blood replenishment during surgery. Introduction. The vertebral column is the commonest site of bony metastasis, accounting for 18,000 new cases in North America yearly. Patients with spinal metastasis are often elderly, have compromised cardiovascular status, poor physiological reserve and altered immune status, all of which render them more susceptible to the complications of intra-operative blood loss and associated transfusion. Currently no consensus exists regarding the expected volume of blood lost during metastatic spine tumour surgery with various papers quoting anywhere between 1L to 6L. Knowledge of the expected blood loss prior to surgery however is important as it facilitates pre-operative planning, intra- and post-operative management of fluid balance and blood transfusion. We conducted a meta-analysis of published literature on spine tumour surgery to answer the question: “What is the expected blood loss in major spinal tumour surgery for metastatic spinal disease?”. Methods. A comprehensive online search of the English literature using Medline, Embase, and the Cochrane Central Register of Controlled Trials was performed. We included articles published from 31 January 1992 until 31 January 2012. This initial online search yielded 98 relevant articles. Two senior investigators independently reviewed all abstracts. The full text of articles that were deemed eligible for further consideration obtained and reviewed. Eighty five articles were excluded at this stage, largely due to lack of clear blood loss data, leaving 13 eligible articles. A hand search of the reference lists of relevant articles yielded 5 more articles. A total of 18 articles were included in the final meta-analysis of blood loss data. Disagreements regarding eligibility of articles for analysis were resolved by consensus. Selected articles for final analysis were independently graded according to the Centre for Evidence-Based Medicine (CEBM) Levels of Evidence. We evaluated the possibility of publication bias by obtaining a funnel plot (created by plotting the sample size against the effect estimate). The Egger's regression asymmetry test was used to assess the existence of publication bias. Results. Eighteen selected articles had a total of 785 patients who had undergone major spine tumour surgery for metastatic spinal disorders. The pooled estimate of the blood loss occurring during spinal tumour surgeries was calculated to be 2180ml (95%CI: 1805–2554ml). Apart from two studies which reported significant mean blood loss of more than 5500 ml, the resulting funnel plot suggested absence of publication bias. This was confirmed by Egger's test which did not show any small-study effects (p=0.119). However, there was strong evidence of heterogeneity between studies with I2=90% (p<0.001). Conclusions. The expected blood loss of a patient undergoing major surgery for spinal tumour constitutes more than a third of the circulating blood volume in a typical cancer patient with significantly impaired physiological reserve. Moreover, cases of catastrophic blood loss exceeding 5L exist in almost every series evaluated in this paper, with some reaching as much as 17–18L. Blood loss is a significant problem during spine tumour surgery and concerted effort is needed to address it


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_16 | Pages 33 - 33
1 Dec 2021
Kakadiya G Chaudhary K
Full Access

Abstract. Objectives. to evaluate the efficacy and safety of topically applied tranexamic acid (TXA) in thoracolumbar spinal tuberculosis surgery, posterior approach. Methods. Thoracolumbar spine tuberculosis patients who requiring debridement, pedicle screw fixation and fusion surgery were divided into two groups. In the TXA group (n=50), the wound surface was soaked with TXA (1 g in 100 mL saline solution) for 3 minutes after exposure, after decompression, and before wound closure, and in the control group (n=116) using only saline. Intraoperative blood loss, drain volume 48 hours after surgery, amount of blood transfusion, transfusion rate, the haemoglobin, haematocrit after the surgery, the difference between them before and after the surgery, incision infection and the incidence of deep vein thrombosis between the two groups. Results. EBL for the control group was 783.33±332.71 mL and for intervention group 410.57±189.72 mL (p<0.001). The operative time for control group was 3.24±0.38 hours and for intervention group 2.99±0.79 hours (p<0.695). Hemovac drainage on days1 and 2 for control group was 167.10±53.83mL and 99.33±37.5 mL, respectively, and for intervention group 107.03±44.37mL and 53.38±21.99mL, respectively (p<0.001). The length of stay was significantly shorter in the intervention group (4.8±1.1 days) compared to control group (7.0±2.3 days). There was bo different in incision side infection and DVT. Conclusions. Topical TXA is a viable, cost-effective method of decreasing perioperative blood loss in major spine surgery with fewer overall complications than other methods. Further studies are required to find the ideal dosage and timing


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_4 | Pages 38 - 38
1 Mar 2021
Nikolaou V Floros T Sourlas I Pappa E Kaseta M Babis G
Full Access

This study aims to investigate that a single dose of tranexamic acid (TXA) will reduce blood loss and transfusion rates in elderly patients, undergoing intertrochanteric (IT) or femoral neck fractures surgery. Consecutive elderly patients receiving hip fracture surgery for stable or unstable IT fracture, treated with short intramedullary nail (IMN) insertion as well as cemented hemiarthroplasty for acute femoral neck (subcapital) hip fracture, were screened for inclusion in this single-centre randomized trial. Patients were randomly allocated to a study group by sealed envelope. One TXA dose of 15 mg/kg i.v. diluted in 100 ml N/S or one placebo dose i.v. in 100 ml N/S were administered 5 mins before the skin cut. Haemoglobin (Hb) concentration was measured at admission time and prior to surgery. Post-operatively it was measured on a daily basis until day 4, giving a total of four Hb measurements (days 1 to 4). The transfusion trigger point was determined in accordance with the French guidelines for erythrocyte blood transfusion. The transfusion trigger was 10 g/dl for patients at risk, while in all other cases, it was 9 g/dl. Information regarding the transfusions number was assessed directly by the hospital blood bank database. Blood loss was calculated by the Hb dilution method. Nadler's formula was used to calculate patients' blood volume. For calculation of total blood loss (TBL) expressed to total Hb loss and total Volume loss, the number of transfusions (55 grams of Hb per transfusion), the Hb concentration on preoperatively (Hgbi) and the Hb concentration on the last measure (Hgbe) were used. (Hb balance method). The primary efficacy outcome was the number of transfusions of allogeneic RBC from surgery up to day 4. The secondary ones were the total blood loss from surgery to day 4 as it was calculated by Hb-balance method. After randomization, 35 patients with femoral neck fracture and 30 patients with IT fracture received TXA prior to surgery. Respectively, 30 patients with femoral neck fracture and 55 with IT fracture didn't receive TXA. The groups did not differ significantly in their basic demographics (age, gender, BMI, injury mechanism, ASA score, co-morbidities). Results showed that patients undergoing hemiarthroplasty after receiving TXA, were transfused with less allogeneic RBC and had less total blood loss than patients that didn't receive TXA, but without statistical significance. While patients treated with IMN in the TXA group received a significantly lower number of RBC units than the control group (1.28 ± 1.049 vs 2.075 ± 1.685), (P = 0.0396), had a significantly lower loss of Hb (98.59 ± 55.24 vs 161.6 ± 141.7), (P = 0.0195) and a lower total blood volume loss (951.3 ± 598.9 ml vs 1513 ± 1247 ml), (P = 0.023). This trial confirmed TXA administration efficacy in reducing blood loss and transfusion rate in elderly patients undergoing hip fracture surgery. A TXA single dose may be a safer option, taking into account these patients' physiological status and co-morbidities


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_9 | Pages 99 - 99
1 May 2017
Bohler I Howse L Baird A Giles N
Full Access

Background. There are multiple documented advantages of undertaking total knee arthroplasty (TKA) without tourniquet, however, increased rates of blood loss and transfusion are often cited as contraindications to this approach. The aim of this study was to examine the effect of intra-operative TA administration on blood loss and transfusion rates in TKA without pneumatic tourniquet, using Rivaroxaban as thrombo-embolic prophylaxis. Method. 120 patients split into two continuous data sets, (A+B), underwent TKA without application of above knee tourniquet, receiving a post operative dose of oral Rivaroxaban within 8 hours. Group B patients received an intra-operative dose of 1 gram of Tranexamic Acid intravenously before the first cut, whilst those in group A did not. Haemoglobin and haematocrit levels were recorded peri-operatively. A revised Gross formula was used to calculate blood loss. Four patients were excluded from the study for incomplete data. Results. 58 patients (M34F24) in Group A, average age 6, had a mean haemoglobin drop of 33gram/litre, haematocrit drop of 0.097litre/litre (9.7%), with an average calculated blood loss of 1393ml. 58 (M34, F24) patients in group B, average age 67, had a haemoglobin drop of 25.2gram/litre, haemotocrit drop of 0.076litre/litre (7.6%) with an average calculated blood loss of1079ml. Thus Group A patients were seen to sustain significantly more blood loss without TA administration, with a 29.1% larger calculated blood loss, a 25.5% larger drop in haemoglobin and a 27.6% larger fall in haematocrit. Transfusion rate was 5.2% (3 patients) per group. Conclusion. TA was shown to be effective in reducing blood loss in TKA without tourniquet using Rivaroxaban. Transfusion rates of 5.2% across both groups is close to 1/10th of the transfusion rate reported for some major studies of TKA using Rivaroxaban with tourniquet application, and 1/8th of the transfusion rate in studies of TKA with administration of TA and use of tourniquet. Level of Evidence. Level-III. The authors report there are no relevant disclosures to make. Ethical approval was granted for the study


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_8 | Pages 50 - 50
1 Apr 2017
Wasko M Bobecka K Wesolowska Pokrzywnicka I Kowalczewski G Kowalczewski J
Full Access

Background. Hitherto, no study has compared blood loss (BL) after different thromoprophylactic regimes (TR). The objective of this study was to quantify and compare BL in total hip arthroplasty (THA) under three different TRs. Methods. Between September 2013 and July 2014, sixty primary, unilateral, same-implant THAs entered a randomised, double-blind clinical trial. The patients were randomised to receive manufacturers' recommended doses of enoxaparin, dabigatran or rivaroxaban. Complete blood counts were obtained preoperatively and on the third day postoperatively. BL was calculated according to the Nadler formula. We also evaluated the occurence of wound healing disturbances (WHDs). All data were analysed using R statistical software. Results. The mean BL and standard deviations were 844 ± 222 ml for enoxaparin, 854 ± 205 ml for dabigatran and 806 ± 227 ml for rivaroxaban. The BL did not significantly differ between groups (Kruskall-Wallis, p=0.92). More WHDs occured in the rivaroxaban group (5/20), compared to enoxaparin (2/20) and dabigatran (3/20). Conclusions. None of the chemical TR is superior to others in terms of reducing the BL. There seems to be more WHDs with the use of oral agents - this finding needs further studies. Level of evidence. 1b (Centre for Evidence Based Medicine, Oxford). Approval. This study was approved by The Medical Centre of Postgraduate Education Ethical Committee. Disclosure. The authors disclose no competing interests


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_7 | Pages 74 - 74
4 Apr 2023
Mariscal G Barrés M Barrios C Tintó M Baixauli F
Full Access

To conduct a meta-analysis for intertrochanteric hip fractures comparing in terms of efficacy and safety short versus long intralomedullary nails. A pubmed search of the last 10 years for intertrochanteric fracture 31A1-31A3 according to the AO/OTA classification was performed. Baseline characteristics of each article were obtained, complication measures were analyzed: Peri-implant fracture, reoperations, deep/superficial infection, and mortality. Clinical variables consisted of blood loss (mL), length of stay (days), time of surgery (min) and nº of transfusions. Functional outcomes were also recorded. A meta-analysis was performed with Review Manager 5.4. Twelve studies were included, nine were retrospective. The reoperations rate was lower in the short nail group and the peri-implant fracture rate was lower in the long nail group (OR 0.58, 95% CI 0.38 to 0.88) (OR 1.88, 95% CI 1.04 to 3.43). Surgery time and blood loss was significantly higher in the long nail group (MD −12.44, 95% CI −14.60 to −10.28) (MD −19.36, 95% CI −27.24 to −11.48). There were no differences in functional outcomes. The short intramedullary nail has a higher risk of peri-implant fracture; however, the reoperation rate is lower compared to the long nail. Blood loss and surgery time was higher in the long nail group


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_1 | Pages 9 - 9
2 Jan 2024
Vadalà G Papalia G Russo F Ambrosio L Franco D Brigato P Papalia R Denaro V
Full Access

The use of intraoperative navigation and robotic surgery for minimally invasive lumbar fusion has been increasing over the past decade. The aim of this study is to evaluate postoperative clinical outcomes, intraoperative parameters, and accuracy of pedicle screw insertion guided by intraoperative navigation in patients undergoing lumbar interbody fusion for spondylolisthesis. Patients who underwent posterior lumbar fusion interbody using intraoperative 3D navigation since December 2021 were included. Visual Analogue Scale (VAS), Oswestry Disability Index (ODI), and Short Form Health Survey-36 (SF-36) were assessed preoperatively and postoperatively at 1, 3, and 6 months. Screw placement accuracy, measured by Gertzbein and Robbins classification, and facet joint infringement, measured by Yson classification, were assessed by intraoperative Cone Beam CT scans performed at the end of instrumentation. Finally, operation time, intraoperative blood loss, hospital stay, and screw insertion time were evaluated. This study involved 50 patients with a mean age of 63.7 years. VAS decreased from 65.8±23 to 20±22 (p<.01). ODI decreased from 35.4%±15 to 11.8%±14 (p<.01). An increase of SF-36 from 51.5±14 to 76±13 (p<.01) was demonstrated. The accuracy of “perfect” and “clinically acceptable” pedicle screw fixation was 89.5% and 98.4%, respectively. Regarding facet violation, 96.8% of the screws were at grade 0. Finally, the average screw insertion time was 4.3±2 min, hospital stay was 4.2±0.8 days, operation time was 205±53 min, and blood loss was 169±107 ml. Finally, a statistically significant correlation of operation time with hospital stay, blood loss and placement time per screw was found. We demonstrated excellent results for accuracy of pedicle screw fixation and violation of facet joints. VAS, ODI and SF-36 showed statistically significant improvements from the control at one month after surgery. Navigation with intraoperative 3D images represents an effective system to improve operative performance in the surgical treatment of spondylolisthesis


The current study aims to compare the clinico radiological outcomes between Non-Fusion Anterior Scoliosis (NFASC) Correction and Posterior Spinal Fusion (PSF) for Lenke 5 curves at 2 years follow up. Methods:38 consecutive Lenke 5 AIS patients treated by a single surgeon with NFASC (group A) or PSF (group B) were matched by age, Cobb's angle, and skeletal maturity. Intraoperative blood loss, operative time, LOS, coronal Cobbs, and SRS22 scores at 2 years were compared. Flexibility was assessed by modified Schober's test. Continuous variables were compared using student t-tests and categorical variables were compared using chi-square. The cohort included 19 patients each in group A and B . Group A had M:F distribution of 1:18 while group B had 2:17. The mean age in group A and group B were 14.8±2.9 and 15.3±3.1 years respectively. The mean follow-up of patients in groups A and B were 24.5±1.8 months and 27.4±2.1 months respectively. Mean pre-op thoracolumbar/lumbar (TL/L) cobbs for group A and group B were 55°±7° and 57.5°±8° respectively. At two years follow up, the cobbs for group A and B were 18.2°±3.6° and 17.6°±3.5° respectively (p=0.09). The average operating time for groups A and B were 169±14.2 mins and 219±20.5 mins respectively (p<0.05). The average blood loss of groups A and B were 105.3±15.4 and 325.3±120.4 respectively (p<0.05). The average number of instrumented vertebra between groups A and B were 6.2 and 8.5 respectively (p<0.05). The average LOS for NFASC and PSF was 3.3±0.9 days and 4.3±1.1 days respectively (p<0.05). No statistically significant difference in SRS 22 score was noted between the two groups. No complications were recorded. Our study shows no significant difference in PSF and NFASC in terms of Cobbs correction and SRS scores, but the NFASC group had significantly reduced blood loss, operative time, and fewer instrumented levels. NFASC is an effective alternative technique to fusion to correct and stabilize Lenke 5 AIS curves with preservation of spinal motion


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_8 | Pages 103 - 103
11 Apr 2023
Domingues I Cunha R Domingues L Silva E Carvalho S Lavareda G Carvalho R
Full Access

Patients who are Jehovah's witnesses do not accept blood transfusions. Thus, total hip arthroplasty can be challenging in this group of patients due to the potential for blood loss. Multiple strategies have been developed in order to prevent blood loss. A 76-year-old female, Jehovah's witness medicated with a platelet antiaggregant, presented to the emergency department after a fall from standing height. Clinically, she had pain mobilizing the right lower limb and radiological examination revealed an acetabular fracture with femoral head protrusion and ipsilateral isquiopubic fracture. Skeletal traction was applied to the femur during three weeks and no weight bearing was maintained during the following weeks. Posteriorly, there was an evolution to hip osteoarthritis with necrosis of the femoral head. The patient was submitted to surgery six months after the initial trauma, for a total hip arthroplasty. The surgery was performed with hypotensive anaesthesia, careful surgical technique and meticulous haemostasis and there was no need for blood transfusion. Posteriorly, there was a positive clinical evolution with progressive improvement on function and deambulation. Total hip arthroplasty may be safely carried out with good clinical outcomes in Jehovah's witnesses, without the need for blood transfusion, if proper perioperative precautions are taken, as has already been shown in previous studies


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_13 | Pages 33 - 33
1 Nov 2021
Hartland A Teoh K Rashid M
Full Access

Introduction and Objective. Tranexamic acid (TXA) is used across surgical specialties to reduce perioperative bleeding. It has been shown to be effective in trauma, spinal surgery, and lower limb arthroplasty. The aim of this study is to investigate the clinical effectiveness of TXA in all types of shoulder surgery on bleeding and non-bleeding related outcomes. Materials and Methods. This study was registered prospectively on the PROSPERO database (ref: CRD42020185482). A systematic review and meta-analysis of randomised controlled trials (RCTs) investigating intra-operative use of TXA versus placebo in any type of surgery to the shoulder girdle. Electronic databases searched included MEDLINE, EMBASE, PsychINFO, and the Cochrane Library. Risk of bias within studies was assessed using the Cochrane risk of bias v2.0 tool and Jadad score. Certainty of findings were reported using the GRADE approach. The primary outcome was total blood loss. Secondary outcomes included patient reported outcome measures, adverse events, and rate of blood transfusion. Results. Eight RCTs were included in the systematic review and data from 7 of these studies pooled in the meta-analysis. A total of 708 patients were randomized across the studies (406 received TXA, 302 received placebo). Studies included patients undergoing anatomic or reverse total shoulder arthroplasty, open Latarjet surgery, and arthroscopic rotator cuff repair. Pooled analysis demonstrated significant reduction in perioperative bleeding with TXA compared to controls; estimated total blood loss (mean difference [MD], −209.66; 95% CI −389.11 to −30.21; p=0.02), and post-operative blood loss (via drain output) (MD, −84.8ml; 95% CI, −140.04 to −29.56; p=0.003). A mean difference in Visual Analogue Scale (VAS) of 2.93 was noted in favour of TXA (95% CI 0.2 to 5.66; p=0.04). Conclusions. Whilst noting some risk of bias within the studies, TXA was effective in reducing blood loss and pain in shoulder surgery. There may be a benefit of TXA use in both open and arthroscopic shoulder procedures. Larger, low risk of bias, RCTs for specific surgical shoulder procedures are required


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_4 | Pages 24 - 24
1 Mar 2021
Sephton B Cruz N Kantharuban S Naique S
Full Access

Blood management protocols attempt to reduce blood loss by strategies including autologous blood donation, red cell salvage, normovolaemic haemodilution and haemostatic agents such as tranexamic acid (TXA). TXA usage in particular has become increasingly commonplace with numerous studies demonstrating a significant reduction in peri-operative blood loss and proportion of patients requiring transfusion, without increasing the risk of venous thromboembolism. Tourniquet usage has now become ubiquitous in TKA operations with reported benefits of improved visualization, shorter operative time and decreased intra-operative bleeding. However, its use is not without considerable complications including wounding dehiscence, increased venous thromboembolism, superficial wound infection and skin blistering. It is therefore imperative that we review tourniquet usage in light of ever evolving blood management strategies. The aim of this study was to evaluate the effect of stopping tourniquet usage in primary TKRs, performed by an experienced surgeon, in light of new blood reduction measures, such as a TXA. A retrospective analysis identified a total of 31 patients who underwent primary TKR without the use of a tourniquet from January 2018 to March 2019. This was compared to an earlier group of patients from the same surgeon undergoing TKR with the use of a tourniquet; dating from July 2016 to November 2017. All surgeries were performed within the same hospital (CXH). Peri-operative factors and outcome measures were collected for analysis. There was no significant difference in post-operative haemoglobin drop (Tourniquet, 23.1 g/L; No Tourniquet, 24.4 g/: p=0.604) and fall in haematocrit (Tourniquet, 0.082; No Tourniquet, 0.087: p=0.604). Allogenic blood transfusion rates were the same in both groups at 12.9% (2 patients) and blood loss was not found to be significantly different (Tourniquet, 1067ml; No tourniquet, 1058mls). No significant difference was found in operative time (Tourniquet, 103 minutes; No Tourniquet, 111.7 minutes: p=0.152) or length of stay (Tourniquet, 5.5 days; No Tourniquet, 5.2 days: p=0.516). Tranexamic acid usage was not found to be significant (p=1.000). ROM of motion and analgesia requirement was significantly better in the no tourniquet group on one post-operative day out of five analysed (p=0.025, p=00.011). No post-operative thromboembolic events were reported in either group. There was no significant difference in readmission rates (p=0.492) or complications (p=0.238). The increase in minor complications and potential increased VTE risk with tourniquet usage must be balanced against an improved visual field and reduced blood loss in TKR patients. Our study found no difference in post-operative blood loss and transfusion rates between tourniquet and no tourniquet groups. With ever evolving and improving blood loss management strategies, including the use of TXA, the application of tourniquet may not be needed. Further prospective RCTs are needed to assess the impact of tourniquet usage in light of this


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_9 | Pages 47 - 47
17 Apr 2023
Akhtar R
Full Access

To compare the efficacy of intra-articular and intravenous modes of administration of tranexamic acid in primary total knee arthroplasty in terms of blood loss and fall in haemoglobin level. Study Design: Randomized controlled trial. Duration of Study: Six months, from May 2019 to Nov 2019. Seventy-eight patients were included in the study. All patients undergoing unilateral primary total knee replacement were included in the study. Exclusion criteria were patients with hepatitis B and C, history of previous knee replacement, bilateral total knee replacement, allergy to TXA, Hb less than 11g/dl in males and less than 10g/dl in females, renal dysfunction, use of anticoagulants for 7 days prior to surgery and history of thromboembolic diseases. Patients were randomly divided into group A and B. Group A patients undergoing unilateral primary total knee replacement (TKR) were given intravenous tranexamic acid (TXA) while group B were infiltrated with intra-articular TXA. Volume of drain output, fall in haemoglobin (Hb) level and need for blood transfusion were measured immediately after surgery and at 12 and 24 hours post operatively in both groups. The study included 35 (44.87%) male and 43 (55.13%) female patients. Mean age of patients was 61 ± 6.59 years. The mean drain output calculated immediately after surgery in group A was 45.38 ± 20.75 ml compared with 47.95 ± 23.86 ml in group B (p=0.73). At 24 hours post operatively, mean drain output was 263.21 ± 38.50 ml in intravenous group versus 243.59 ± 70.73 ml in intra-articular group (p=0.46). Regarding fall in Hb level, both groups showed no significant difference (p>0.05). About 12.82% (n=5) patients in group A compared to 10.26% (n=4) patients required blood transfusion post operatively (p=0.72). Intra-articular and intravenous TXA are equally effective in patients undergoing primary total knee arthroplasty in reducing post-operative blood loss


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_9 | Pages 49 - 49
17 Apr 2023
Cooper G Kennedy M Jamal B Shields D
Full Access

Our objective was to conduct a systematic review and meta-analysis, comparing differences in clinical outcomes between either autologous or synthetic bone grafts in the operative management of tibial plateau fractures: a traumatic pattern of injury, associated with poor long-term functional prognosis. A structured search of MEDLINE, EMBASE, The Bone & Joint and CENTRAL databases from inception until 07/28/2021 was performed. Randomised, controlled, clinical trials that compared autologous and synthetic bone grafts in tibial plateau fractures were included. Preclinical studies, clinical studies in paediatric patients, pathological fractures, fracture non-union or chondral defects were excluded. Outcome data was assessed using the Risk of Bias 2 (ROB2) framework and synthesised in random-effect meta-analysis. Preferred Reported Items for Systematic Review and Meta-Analysis guidance was followed throughout. Six comparable studies involving 352 patients were identified from 3,078 records. Following ROB2 assessment, five studies (337 patients) were eligible for meta-analysis. Within these studies, more complex tibia plateau fracture patterns (Schatzker IV-VI) were predominant. Primary outcomes showed non-significant reductions in articular depression at immediate postoperative (mean difference −0.45mm, p=0.25, 95% confidence interval (95%CI): −1.21-0.31mm, I. 2. =0%) and long-term (>6 months, standard mean difference −0.56, p=0.09, 95%CI: −1.20-0.08, I. 2. =73%) follow-up in synthetic bone grafts. Secondary outcomes included mechanical alignment, limb functionality, defect site pain, occurrence of surgical site infections, secondary surgery, perioperative blood loss, and duration of surgery. Blood loss was lower (90.08ml, p<0.001, 95%CI: 41.49-138.67ml, I. 2. =0%) and surgery was shorter (16.17minutes, p=0.04, 95%CI: 0.39-31.94minutes, I. 2. =63%) in synthetic treatment groups. All other secondary measures were statistically comparable. Our findings supersede previous literature, demonstrating that synthetic bone grafts are non-inferior to autologous bone grafts, despite their perceived disadvantages (e.g. being biologically inert). In conclusion, surgeons should consider synthetic bone grafts when optimising peri-operative patient morbidity, particularly in complex tibial plateau fractures, where this work is most applicable


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_4 | Pages 25 - 25
1 Mar 2021
Sephton B Edwards TC Bakhshayesh P Nathwani D
Full Access

In recent years, reduction in the length of stay in patients undergoing UKA has gained considerable interest. This has led to development of ‘fast-track' and even day-case protocols aimed at decreasing length of stay (LOS), enhancing post-operative recovery and decreasing post-operative morbidity. One potential barrier to faster discharge and patient recovery is the need for post-operative haemoglobin checks and allogenic blood transfusion; which has been shown to increase LOS. Allogenic blood transfusion itself is not without risk, including immunological reactions, transfusion associated lung injury, infection and transmission of disease, thus reducing blood loss and the need for transfusion is imperative. Currently there is a knowledge gap regarding post-operative transfusion need and blood loss following UKA. We aimed to investigate blood loss and transfusion rates following UKA. Our primary aim was to evaluate the extent of post-operative transfusion need following UKA and identify which patients are at higher risk of needing transfusion. Following institutional approval, a retrospective analysis of all patients undergoing unicompartmental knee arthroplasty (UKA) at our level one academic university hospital was conducted. Operative records of all patients undergoing primary UKA were reviewed between March 2016 and March 2019. Patients' pre-operative haemoglobin and haematocrit, BMI, co-morbidities, application of tourniquet, tourniquet time, administration of Tranexamic Acid, need for post-operative blood transfusion, hospital length of stay, complications and re-admission were all recorded. Blood loss was estimated using the post-operative haematocrit. A total number of 155 patients were included. There were 70 females (45%) and 85 males (55%). The mean age was 66±10 years. Median pre-op blood volume was 4700mls (IQR; 4200–5100). Median blood loss was 600 mls (IQR; 400–830). Mean pre-op Haemoglobin was 135±14g/L and mean post-op Haemoglobin was 122±13g/L. No patient had a post-op Haemoglobin under 80g/L (Range 93–154). No patients in our study needed transfusion. A further comparison group of high-blood loss and low-blood loss patients was included in analysis. High-blood loss patients were defined as those losing greater than 20% of their pre-operative blood volume whilst low-blood loss patients were defined as those losing ≤20% of their blood volume. Results of these groups are presented in Table 3. No significance was found between the two groups in patient's demographics and in terms of intra-operative factors including TXA usage (p=0.68) and tourniquet time (p=0.99). There was no difference in terms of post-operative complications (p=1.0), length of stay (p=0.36) or readmission rates (p=0.59). The results of our study indicated that post-operative haemoglobin and haematocrit check proved unnecessary in all of our patients and could have been omitted from post-operative routines. We conclude that routine post UKA check of haemoglobin and haematocrit can be avoided and be saved for special circumstances depending on patient's physiology


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_4 | Pages 5 - 5
1 Mar 2021
Kumar G Debuka E
Full Access

Increasing incidence of osteoporosis, obesity and an aging population have led to an increase in low energy hip fractures in the elderly. Perceived lower blood loss and lower surgical time, media coverage of minimal invasive surgery and patient expectations unsurprisingly have led to a trend towards intramedullary devices for fixation of extracapsular hip fractures. This is contrary to the Cochrane review of random controlled trials of intramedullary vs extramedullary implants which continues recommends the use of a sliding hip screw (SHS) over other devices. Furthermore, despite published literature of minimally invasive surgery (MIS) of SHS citing benefits such as reduced soft tissue trauma, smaller scar, faster recovery, reduced blood loss, reduced analgesia needs; the uptake of these approaches has been poor. We describe a novel technique one which remains minimally invasive, that not only has a simple learning curve but easily reproducible results. All patients who underwent MIS SHS fixation of extracapsular fractures were included in this study. Technique is shown in Figure 1. We collated data on all intertrochanteric hip fractures that were treated by a single surgeon series during period Jan 2014 to July 2015. Data was collected from electronic patient records and radiographs from Picture Archiving and Communication System (PACS). Surgical time, fluoroscopy time, blood loss, surgical incision length, post-operative transfusion, Tip Apex Distance (TAD) were analyzed. There were 10 patients in this study. All fractures were Orthopaedic Trauma Association (OTA) type A1 or A2. Median surgical time was 36 minutes (25–54). Mean fluoroscopy time was similar to standard incision sliding hip screw fixation. Blood loss estimation with MIS SHS can be undertaken safely and expeditiously for extracapsular hip fractures


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_11 | Pages 13 - 13
1 Dec 2020
Erinç S Kemah B Öz T
Full Access

Introduction. This study aimed to compare MIPO and IMNr in the treatment of supracondylar femur fracture following TKA in respect of fracture healing, complications and functional results. Materials and Methods. A retrospective analysis was made of 32 supracondylar femur fractures classified according to the Rorabeck classification, comprising 20 cases treated with MIPO and 12 with IMNr. The two techniques were compared in respect of ROM, KSS, SF-12 scores, intraoperative blood loss, surgery time, and radiological examination findings. Results. No significant difference was determined between the two groups in respect of age, gender and fracture type, or in the median time to union (MIPO 4.3 months, IMNr 4.2 mths) (p >0.05). In the MIPO group, 2 patients had delayed union, so revision surgery was applied. The mean postoperative ROM was comparable between IMNr and MIPO (86.2 °vs 86 °, p > 0.05). The mean Knee Society Score (KSS) and SF-12 score did not differ between the IMN and MIPO groups. (p>0.05). Reduction quality in the sagittal plane was better in the MIPO group and no difference was determined in coronal alignment. Greater shortening of the lower extremity was seen in the IMNr group than in the MIPO group. (20.3 vs 9.3mm, p<0.05). Perioperative blood loss was greater (2 units vs.1.2 units) and mean operating time was longerin the MIPO group. (126.5 min vs 102.2 min, p<0.05). Conclusion. In patients with good bone stock, supracondylar femur fracture following TKA can be treated successfully with IMN or MIPO. IMN has the advantage of less blood loss and a shorter operating time. Reduction quality may be improved with the MIPO technique. Both surgery techniques can be successfully used by orthopaedic surgeons taking a case-by-case approach


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_13 | Pages 109 - 109
1 Nov 2021
Rigney B Casey C Donald CM Pomeroy E Cleary M
Full Access

Introduction and Objective. Wide awake local anaesthetic no tourniquet (WALANT) is being used for a wide variety of hand and wrist surgery. It has recently been used in distal radius fracture fixation. The purpose of this systematic review and meta-analysis was to assess the effectiveness of the WALANT technique in open reduction internal fixation. Materials and Methods. Pubmed, Embase, and Scopus databases were searched on 02/03/21 with the following search terms: radius, WALANT, local anesthetic, wide awake surgery. The primary outcome measure was conversion to general anaesthetic and mean intra-operative visual analogue scale (VAS) pain scores. Secondary measures were operative times, mean intraoperative blood loss, post-operative functional and radiological outcomes. Results. 110 articles were identified; eight studies were deemed eligible with 212 in the WALANT group and 247 in the comparative groups of regional anaesthesia and general Anaesthesia (GA). Two patients in the WALANT group required conversion to general anaesthesia due to anxiety rather than pain. Intra-operative VAS pain scores in the WALANT and regional anaesthetic group were 1.75 and 2.86 respectively (p<0.001). There was no statistically significant difference in Q-DASH scores, range of motion or radiological outcomes. There was a slight increase in mean blood loss in the WALANT group compared with those given a GA or regional anaesthetic with tourniquet (22.5ml vs 12.15ml, p<0.001). Conclusions. The WALANT technique is a viable option for anaesthetic when performing distal radius fracture fixation. It is well tolerated, giving similar post-operative outcomes to other anaesthetic methods. It is a potentially useful technique in a centre with an underresourced anaesthetic department or for patients who may not tolerate regional and general anaesthetic methods. Adequate patient counselling prior to the procedure should be performed with appropriate patient selection


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_4 | Pages 48 - 48
1 Mar 2021
AlSaleh K Aldawsari K Alsultan O Awwad W Alrehaili O
Full Access

Posterior spinal surgery is associated with a significant amount of blood loss. The factors predisposing the patient to excessive bleeding-and therefore transfusion- are not well established nor is the effect of transfusion on the outcomes following spinal surgery. We had two goals in this study. First, we were to investigate any suspected risk factors of transfusion in posterior thoraco-lumbar fusion patients. Second, we wanted to observe the negative impact-if one existed- of transfusion on the outcomes of surgery. All adults undergoing posterior thoraco-lumbar spine fusion in our institution from May 2015 to May 2018 were included. Data collected included demographic data as well as BMI, preoperative hemoglobin, American Society of Anesthesiologists classification (ASA), delta Hemoglobin, estimated blood loss, incidence of transfusion, number of units transfused, number of levels fused, length of stay and re-admission within 30 days. The data was analyzed to correlate these variables with the frequency of transfusion and then to assess the association of adverse outcomes with transfusion. 125 patients were included in the study. Only 6 patients (4.8%) required re-admission within the first 30 days after discharge. Length of stay averaged 8.4 days (3–74). 18 patients (14.4%) required transfusion peri-operatively. When multiple variables were analyzed for any correlation, the number of levels fused, age and BMI had statistically significant correlation with the need for transfusion (P <0.005). Patients undergoing posterior thoraco-lumbar fusion are more likely to require blood transfusion if they were older, over-weight & obese or had a multi-level fusion. Receiving blood transfusion is associated with increased complication rates


The current study aims to find the role of Enhance Recovery Pathway (ERP) as a multidisciplinary approach aimed to expedite rapid recovery, reduce LOS, and minimize morbidity associated with Non Fusion Anterior Scoliosis Correction (NFASC) surgery. A retrospective analysis of 35 AIS patients who underwent NFASC with Lenke 1 and Lenke 5 curves with a minimum of 1 year of follow-up was done. Patient demographics, surgical details, postoperative analgesia, mobilization, length of stay (LOS), patient satisfaction survey score with respect to information and care, and 90 days complications were collected. The cohort included 34 females and 1 male with a mean age of 15.2 years at the time of surgery. There were 16 Lenke 1 and 19 Lenke 5 in the study. Mean preoperative major thoracic and thoracolumbar/lumbar Cobb's angle were 52˚±7.6˚ and 51˚±4.5˚ respectively. Average blood loss and surgical time were 102 ±6.4 ml and 168 ± 10.2 mins respectively. Average time to commencing solid food was 6.5±1.5 hrs. Average time to mobilization following surgery was 15.5± 4.3 hrs. The average duration to the stopping of the epidural was 42.5±3.5 hrs. The average dose of opioid consumption intraoperatively was 600.5±100.5 mcg of fentanyl i.v. and 12.5±4.5 mg morphine i.v. Postoperatively opioids were administered via an epidural catheter at a dose of 2 mg of morphine every 24 hours up to 2 days and an infusion of 2mcg/hr of fentanyl along with 0.12-0.15% ropivacaine. The average duration to transition to oral analgesia was 55.5±8.5 hrs .20 patients had urinary catheter and the average time to removal of the catheter was 17.5±1.4 hrs. 25 patients had a chest tube and the average time to remove of chest tube was 25.5±3.2 hrs. The average length of hospital stay was 3.1±0.5 days. No patient had postoperative ileus or requirement of blood transfusion or any other complications. No correlation was found between LOS and initial cobb angle. The application of ERP in AIS patients undergoing NFASC results in reduced LOS and indirectly the cost, reduced post-operative opioid use, and overall improve patient satisfaction score