Abstract. Introduction. All-tissue quadriceps tendon (QT) is becoming an increasingly popular alternative to hamstrings tendon (HT) and bone-tendon-bone (BTB) autograft for anterior cruciate ligament (ACL) reconstruction. The relatively short graft length however dictates that one, or both, ends rely on suture fixation. The strength of this construct is therefore extremely important. This study evaluates whether the use of a novel fixation technique can improve the tensile properties of the construct compared to a Krackow suture, and a looped tendon (suture free) gold standard. Methods. Eighteen porcine flexor tendons were tested, across three groups; suture-tape Krackow, looped tendon, and the novel ‘strain suture’.
Introduction. Identifying knee osteoarthritis patient phenotypes is relevant to assessing treatment efficacy.
This study compared biomechanical and functional parameters of a total knee arthroplasty (TKA) implant (Cemented Zimmer Hi-Flex) against healthy older adults to determine whether knee biomechanics was restored in this patient population. Patients with a primary TKA and healthy adults >55 years old with no musculoskeletal deficits or arthritis participated. Bilateral knee range of motion (RoM) was assessed with a goniometer, then gait patterns were analysed with a 3D motion-capture system. An arthrometer then quantified anterior-posterior laxity of each knee. Statistical analyses were performed in SPSS (α=0.05; required sample size: n=21 per group).Abstract
Introduction
Methodology
Autologous chondrocyte implantation (ACI) is a common procedure, primarily performed in active, young patients to treat knee pain and functional limitations resulting from cartilage injury. Nevertheless, the functional outcomes of ACI remain poorly understood. Thus, the aim of this systematic review was to evaluate the biomechanical outcomes of ACI. Ovid MEDLINE, Embase, and Web of Science were systematically searched using the terms ‘Knee OR Knee joint AND Autologous chondrocyte implantation OR ACI’. Strict inclusion and exclusion criteria were used to screen publications by title, abstract, and full text. Study quality and bias were assessed by two reviewers. PROSPERO ID: CRD42021238768.Abstract
Introduction
Methodology
MCL injuries often occur concurrently with ACL rupture – most noncontact ACL injuries occur in valgus and external rotation (ER) - and conservative MCL treatment leads to increased rate of ACL reconstruction failure. There has been little work developing effective MCL reconstructions. Cadaveric work measured MCL attachments by digitisation and radiographically, relating them to anatomical landmarks. The isometry of the superficial and deep MCL (sMCL and dMCL) and posterior oblique ligament (POL) was measured using fine sutures led to displacement transducers. Contributions to stability (restraint) were measured in a robotic testing system. Two MCL reconstructions were designed and tested: 3-strand reconstruction (sMCL+dMCL+POL), and 2-strand method (sMCL+dMCL) addressing anteromedial rotatory instability (AMRI). The resulting stability was measured in a kinematics test rig, and compared to the ‘anatomic’ sMCL+POL reconstruction of LaPrade.Abstract
Introduction
Methods
Previous research has shown that, notwithstanding ligament healing, properly selected MCL reconstruction can restore normal knee stability after MCL rupture. The hypothesis of this work was that it is possible to restore knee stability (particularly valgus and AMRI) with simplified and/or less-invasive MCL reconstruction methods. Nine unpaired human knees were cleaned of skin and fat, then digitization screws and optical trackers were attached to the femur and tibia. A Polaris stereo camera measured knee kinematics across 0o-100o flexion when the knee was unloaded then with 90N anterior-posterior force, 9Nm varus-valgus moment, 5Nm internal-external rotation, and external+anterior (AMRI) loading. The test was conducted for the following knee conditions: intact, injured: transected superficial and deep MCL (sMCL and dMCL), and five reconstructions: (long sMCL, long sMCL+dMCL, dMCL, short sMCL+dMCL, short sMCL), all based on the medial epicondyle isometric point and using 8mm tape as a graft, with long sMCL 60mm below the joint line (anatomical), short sMCL 30mm, dMCL 10mm (anatomical).Abstract
Introduction
Methods
Tibial tubercle osteotomy (TTO) is a complex surgical procedure with a significant risk of complications, which include nonunion and tibial fracture. To determine whether an additional suture tape augmentation can provide better biomechanical stability compared with standard screw fixation. Five matched pairs of human cadaveric knees were divided into 2 groups: the first group underwent standard TTO fixation with 2 parallel screws. The second group underwent a novel fixation technique, in which a nonabsorbable suture tape (FiberTape) in a figure-of-8 construct was added to the standard screw fixation. Tubercular fragment migration of >50% of the initial distalization length was defined as clinical failure Tubercular fragment displacement during cyclic loading and pull-to-failure force were recorded and compared between the 2 groups.Abstract
Introduction
Methods
Unicompartmental knee arthroplasty (UKA) has become a popular method of treating knee localized osteoarthritis (OA). Additionally, the posterior cruciate ligament (PCL) is essential to maintaining the physiological kinematics and functions of the knee joint. Considering these factors, the purpose of this study was to investigate the biomechanical effects on PCL-deficient knees in medial UKA. Computational simulations of five subject-specific models were performed for intact and PCL-deficient UKA with tibial slopes. Anteroposterior (AP) kinematics and contact stresses of the patellofemoral (PF) joint and the articular cartilage were evaluated under the deep-knee-bend condition.Aims
Methods
Aseptic loosening of the femoral component is
an important indication for revision surgery in unicompartmental knee
replacement (UKR). A new design of femoral component with an additional
peg was introduced for the cemented Oxford UKR to increase its stability.
The purpose of this study was to compare the primary stability of
the two designs of component. Medial Oxford UKR was performed in 12 pairs of human cadaver
knees. In each pair, one knee received the single peg and one received
the twin peg design. Three dimensional micromotion and subsidence
of the component in relation to the bone was measured under cyclical
loading at flexion of 40° and 70° using an optical measuring system.
Wilcoxon matched pairs signed-rank test was performed to detect
differences between the two groups. There was no significant difference in the relative micromotion
(p = 0.791 and 0.380, respectively) and subsidence (p = 0.301 and
0.176, respectively) of the component between the two groups at
both angles of flexion. Both designs of component offered good strength
of fixation in this cadaver study. Cite this article:
This study explores whether subjects with bicruciate retaining TKRs (BiCR) have more normal knee biomechanics during level walking and stair ascent than subjects with posterior cruciate retaining TKRs (PCR). Due to anterior cruciate ligament (ACL) preservation, we expect BiCR subjects will not show the reduced flexion and altered muscle activation patterns characteristic of persons with TKRs. Motion and electromyography (EMG) data were collected during level walking and stair climbing for 16 BiCR subjects (4/12 m/f, 65±3 years, 30.7±7.0 BMI, 8/8 R/L), 17 PCR subjects (2/15 m/f, 65±7 years, 30.4±5.1 BMI, 7/10 R/L), and 17 elderly healthy control subjects (8/9 m/f, 55±10 years, 25.8±4.0 BMI, 10/7 R/L), using the point cluster marker set. Surface EMG electrodes were placed on the vastus medialis obliquus (VMO), rectus femoris (RF), biceps femoris (BF), and semitendinosus (ST) muscles. EMG data are reported as percent relative voluntary contraction (%RVC), normalized to the average peak EMG signals during level walking. Statistical nonparametric mapping was used for waveform analysis.Introduction
Methods
To determine the tensile forces across the knee extensor mechanism during walking, in simulated conditions of treatment. Gait analysis of six normal subjects was performed, with full weight bearing unilateral immobilisation of the knee during walking. Measurements were taken without then with a brace, unlocked then locked at 0°, 0-10°, 0-20° and 0-30° of flexion. Mean and maximum knee flexion angles were measured, followed by calculation of the mean and maximum forces across the extensor mechanism during loading, supporting and propulsion phases of gait.Aim
Methods
Aims. As has been shown in larger animal models, knee immobilization can lead to arthrofibrotic phenotypes. Our study included 168 C57BL/6J female mice, with 24 serving as controls, and 144 undergoing a knee procedure to induce a contracture without osteoarthritis (OA). Methods. Experimental knees were immobilized for either four weeks (72 mice) or eight weeks (72 mice), followed by a remobilization period of zero weeks (24 mice), two weeks (24 mice), or four weeks (24 mice) after suture removal. Half of the experimental knees also received an intra-articular injury.
Advances in polyethylene (PE) in total hip arthroplasty
have led to interest and increased use of highly crosslinked PE
(HXLPE) in total knee arthroplasty (TKA).
The tibial component of total knee arthroplasty can either be an all-polyethylene (AP) implant or a metal-backed (MB) implant. This study aims to compare the five-year functional outcomes of AP tibial components to MB components in patients aged over 70 years. Secondary aims are to compare quality of life, implant survivorship, and cost-effectiveness. A group of 130 patients who had received an AP tibial component were matched for demographic factors of age, BMI, American Society of Anesthesiologists (ASA) grade, sex, and preoperative Knee Society Score (KSS) to create a comparison group of 130 patients who received a MB tibial component. Functional outcome was assessed prospectively by KSS, quality of life by 12-Item Short-Form Health Survey questionnaire (SF-12), and range of motion (ROM), and implant survivorships were compared. The SF six-dimension (6D) was used to calculate the incremental cost effectiveness ratio (ICER) for AP compared to MB tibial components using quality-adjusted life year methodology.Aims
Methods
Mid-level constraint designs for total knee arthroplasty (TKA) are intended to reduce coronal plane laxity. Our aims were to compare kinematics and ligament forces of the Zimmer Biomet Persona posterior-stabilized (PS) and mid-level designs in the coronal, sagittal, and axial planes under loads simulating clinical exams of the knee in a cadaver model. We performed TKA on eight cadaveric knees and loaded them using a robotic manipulator. We tested both PS and mid-level designs under loads simulating clinical exams via applied varus and valgus moments, internal-external (IE) rotation moments, and anteroposterior forces at 0°, 30°, and 90° of flexion. We measured the resulting tibiofemoral angulations and translations. We also quantified the forces carried by the medial and lateral collateral ligaments (MCL/LCL) via serial sectioning of these structures and use of the principle of superposition.Aims
Methods
Patient dissatisfaction is not uncommon following primary total knee arthroplasty. One proposed method to alleviate this is by improving knee kinematics. Therefore, we aimed to answer the following research question: are there significant differences in knee kinematics based on the design of the tibial insert (cruciate-retaining (CR), ultra-congruent (UC), or medial congruent (MC))? Overall, 15 cadaveric knee joints were examined with a CR implant with three different tibial inserts (CR, UC, and MC) using an established knee joint simulator. The effects on coronal alignment, medial and lateral femoral roll back, femorotibial rotation, bony rotations (femur, tibia, and patella), and patellofemoral length ratios were determined.Aims
Methods
Introduction. Clinical observations suggest mid-flexion instability may occur more commonly with rotating platform (RP) total knee arthroplasty (TKA), including increased revision rates and patient-reported instability and pain. We propose that increased gap laxity leads to liftoff of the lateral femoral condyle with decreased conformity between the femoral component and polyethylene (PE) insert surface leading to PE subluxation or dislocation. The objectives of this study were to define “at risk” loading conditions that predispose patients to PE insert subluxation or spinout, and to quantify the margin of error for flexion/extension gap laxity in preventing these adverse events under physiologic loading conditions. Methods.
The aim of this study was to compare any differences in the primary outcome (biphasic flexion knee moment during gait) of robotic arm-assisted bi-unicompartmental knee arthroplasty (bi-UKA) with conventional mechanically aligned total knee arthroplasty (TKA) at one year post-surgery. A total of 76 patients (34 bi-UKA and 42 TKA patients) were analyzed in a prospective, single-centre, randomized controlled trial. Flat ground shod gait analysis was performed preoperatively and one year postoperatively. Knee flexion moment was calculated from motion capture markers and force plates. The same setup determined proprioception outcomes during a joint position sense test and one-leg standing. Surgery allocation, surgeon, and secondary outcomes were analyzed for prediction of the primary outcome from a binary regression model.Aims
Methods
Stemmed tibial components are frequently used in revision total knee arthroplasty (TKA). The purpose of this study was to evaluate patient satisfaction, overall pain, and diaphyseal tibial pain in patients who underwent revision TKA with cemented or uncemented stemmed tibial components. This is a retrospective cohort study involving 110 patients with revision TKA with cemented versus uncemented stemmed tibial components. Patients who underwent revision TKA with stemmed tibial components over a 15-year period at a single institution with at least two-year follow-up were assessed. Pain was evaluated through postal surveys. There were 63 patients with cemented tibial stems and 47 with uncemented stems. Radiographs and Knee Society Scores were used to evaluate for objective findings associated with pain or patient dissatisfaction. Postal surveys were analyzed using Fisher’s exact test and the independent-samples Aims
Methods
We investigated the clinical, arthroscopic and biomechanical outcome of transplanting autologous chondrocytes, cultured in atelocollagen gel, for the treatment of full-thickness defects of cartilage in 28 knees (26 patients) over a minimum period of 25 months. Transplantation eliminated locking of the knee and reduced pain and swelling in all patients. The mean Lysholm score improved significantly. Arthroscopic assessment indicated that 26 knees (93%) had a good or excellent outcome. There were few adverse features, except for marked hypertrophy of the graft in three knees, partial detachment of the periosteum in three and partial ossification of the graft in one.