Advertisement for orthosearch.org.uk
Results 1 - 3 of 3
Results per page:
Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_10 | Pages 12 - 12
1 Feb 2013
Clement A Baird K
Full Access

A review of current literature describes varying 10-year survival rates for the Oxford Unicompartmental Knee Replacement (Biomet Orthopedics Inc, Warsaw, Ind). Application of rigorous indications and meticulous surgical technique are two factors considered to reduce revision rates. A retrospective case-note review was conducted for 96 patients (128 knees) aged 42–89 (mean 57) who had an Oxford unicompartmental knee replacement for medial compartment osteoarthritis between January 2000 and January 2011. All procedures were performed, or directly supervised, by one 5 surgeons. The aim of the study was to ascertain the rate of revision to bicompartmental knee replacement and any associated contributory factors. Of the 128 unicompartmental knees, 10.9% were revised to either mobile- or fixed-bearing total knee replacements due to septic (0.5%) and aseptic (1.5%) loosening, patello-femoral pain (3.9%), periprosthetic fracture (0.8%) and bearing dislocation (3.1%). Of those knees requiring revision, mean patient age was 73 years, 50% had wound complications and 42% were performed by senior trainees. All patients had intact ACL and medial osteoarthritis. Mean time to revision was 2.7 years. In conclusion, revision of the unicompartmental knee was related to patient age > 65 years and early post-operative complications; grade of operating surgeon had little apparent effect


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 422 - 422
1 Sep 2012
Weston-Simons J Pandit H Kendrick B Beard D Gibbons M Jackson W Gill H Price A Dodd C Murray D
Full Access

Introduction. The options for the treatment of the young active patient with unicompartmental symptomatic osteoarthritis and pre-existing Anterior Cruciate Ligament (ACL) deficiency are limited. Patients with ACL deficiency and end-stage medial compartment osteoarthritis are usually young and active. The Oxford Unicompartmental Knee Replacement (UKA) is a well established treatment option in the management of symptomatic end-stage medial compartmental osteoarthritis, but a functionally intact ACL is a pre-requisite for its satisfactory outcome. If absent, high failure rates have been reported, primarily due to tibial loosening. Previously, we have reported results on a consecutive series of 15 such patients in whom the ACL was reconstructed and patients underwent a staged or simultaneous UKA. The aim of the current study is to provide an update on the clinical and radiological outcomes of a large, consecutive cohort of patients with ACL reconstruction and UKA for the treatment of end-stage medial compartment osteoarthritis and to evaluate, particularly, the outcome of those patients under 50. Methods. This study presents a consecutive series of 52 patients with ACL reconstruction and Oxford UKA performed over the past 10 years (mean follow-up 3.4 years). The mean age was 51 years (range: 36–67). Procedures were either carried out as Simultaneous (n=34) or Staged (n=18). Changes in clinical outcomes were measured using the Oxford Knee Score (OKS), the change in OKS (OKS=Post-op − Pre-op) and the American Knee Society Score (AKSS). Fluoroscopy assisted radiographs were taken at each review to assess for evidence of loosening, radiolucency progression, (if present), and component subsidence. Results. Five year survival was 90%. At last follow-up, the mean outcome scores for the group were: OKS 40 (SD: 8.3), objective AKSS 77 (SD: 16.1), functional AKSS 93 (SD: 13.7) and OKS of 11. Complications were recorded in three patients, (one early infection requiring a two-stage revision, a bearing dislocation and progression of OA in the lateral compartment). 25 patients, whose procedure occurred under the age of 50, had mean outcome scores of: OKS 38 (SD: 7.7), objective AKSS 73 (SD: 20.2), functional AKSS 93 (SD: 11.9) and OKS 12. No patients had radiological evidence of component loosening. Discussion and Conclusion. This study has demonstrated that combined ACL reconstruction and Oxford UKA provide good medium-term clinical and radiological results. The mobile bearing used in the Oxford knee minimises wear and our radiographic study has seen no suggestions of loosening


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 249 - 249
1 Sep 2012
Kendrick B Weston-Simons J Sim F Gibbons M Pandit H Gill H Price A Dodd C Murray D
Full Access

Introduction. Radiolucencies beneath the tibial component are well recognized in knee arthroplasty; the aetiology and significance are poorly understood. Non-progressive narrow radiolucencies with a sclerotic margin are thought not to be indicative of loosening. Factors which decrease the incidence of radiolucencies include cementless fixation and the use of pulse lavage. Leg/component alignment or BMI do not influence radiolucency. We are not aware of any studies that have looked at the effect of load type on radiolucency. The Oxford domed lateral tibial component was introduced to decrease the bearing dislocation rate that was unacceptably high with the flat tibial tray. However, the introduction of the domed tibial component alters the forces transmitted through the implant-cement-bone interface. As the Oxford UKR uses a fully congruent mobile bearing, the forces transmitted through the interface with a flat tray are compressive, except for the effect of friction. However, with the domed tibial component shear forces are introduced. The aim of this study was to assess the prevalence of radiolucency beneath the previous flat design and the new domed tibial tray. Patients and methods. A consecutive series of 248 cemented lateral UKRs (1999–2009) at a single institution were assessed. The first 55 were with a flat tibia and the subsequent 193 with a domed component. One year post-op radiographs were assessed, by two observers, for the presence (full or partial) and distribution of radiolucency. The distribution and thickness of each radiolucency. Cases were excluded for missing or poorly aligned radiographs. Results. In the flat group there were 42 patients (17 male, 25 female) with 42 joints. In the domed group there were 139 patients (44 male, 95 female) with 146 joints. There was a statistical significant difference between groups for the presence and extent of radiolucency (p<0.001). In the flat group, 6 (14%) had a full radiolucency and 18 (43%) had a partial radiolucency. 14 of the 18 partial radiolucencies involved the far lateral zones (1&2) and 3 partial radiolucencies involved the keel. In the domed group 6, (4.1%) had a full radiolucency and 13 (8.9%) had a partial radiolucency. All radiolucencies observed were less than 1 mm thick. Intra-class correlation for inter-observer agreement for assessment of radiolucency was 0.679. Discussion. The introduction the domed lateral tibial component results in a reduction in prevalence of radiolucency compared to a flat component. This suggests, as the mode of fixation is identical, that the forces across the tibial-cement-bone interface have a significant effect on the development of the tissue at that interface. In particular it suggests that compressive forces alone tend to cause soft tissue to be formed at the interface, whereas shear force causes bone