Advertisement for orthosearch.org.uk
Results 1 - 8 of 8
Results per page:
Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_16 | Pages 18 - 18
1 Apr 2013
Augat P Betz V Schroeder C Goettlinger M Jansson V Mueller PE Betz OB
Full Access

Common cell based strategies for treating bone defects require time-consuming and expensive isolation and expansion of autologous cells. We developed a novel expedited technology creating gene activated muscle grafts. We hypothesized that BMP-2 activated muscle grafts provide healing capabilities comparable to autologous bone grafting, the clinical gold standard. Two male, syngeneic Fischer 344 rats served as tissue donors. Muscle tissue was harvested from hind limbs and incubated with an adenoviral vector carrying the cDNA encoding BMP-2. Bone tissue was harvested from the iliac crest. Segmental bone defects were created in the right femora of 12 rats and were filled with either BMP-2 activated muscle tissue or bone grafts. After 8 weeks, femora were evaluated by radiographs, microCT, and biomechanical tests. BMP-2 activated muscle grafts and autologous bone grafts resulted in complete mineralization and healing, as documented by radiographs and microCT. Bone volume in the muscle graft defects (33+/-12mm3) was similar to autologous bone graft defects (39+/-5mm3). Torque at failure of the two groups was statistically indistinguishable (240+/-115 Nmm vs. 232+/-108Nmm). In previous experiments we demonstrated that the large segmental defect model in this study will not heal with either empty defects or non-activated muscle grafts. Our findings therefore demonstrate that BMP-2 gene activation of muscle tissue effectively stimulates defect healing similar to autologous bone grafts


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_3 | Pages 2 - 2
1 Feb 2020
Shields D Llopis-Hernandez V Jayawarna V Gonzales-Garcia C Marshall W Dalby M Salmeron-Sanchez M
Full Access

Osteoinductive bone substitutes are in their developmental infancy and a paucity of effective grafts options persists despite clinical demand. Bone mineral substitutes such as hydroxyapatite cause minimal biological activity when compared to osteoinductive systems present biological growth factors in order to drive bone regeneration. We have previously demonstrated the in-vitro efficacy of a bioengineered system at presenting growth factors at ultra low-doses. This study aimed to translate this growth factor delivery system towards a clinically applicable implant. Osteoinductive surfaces were engineered using plasma polymerisation of poly(ethyl acrylate) onto base materials followed by adsorption of fibronectin protein and subsequently growth factor (BMP-2). Biological activity following ethylene oxide (EO) sterilisation was evaluated using ELISAs targeted against BMP-2, cell differentiation studies and atomic force microscopy. Scaffolds were 3D printed using polycaprolactone/hydroxyapatite composites and mechanically tested using a linear compression models to calculate stress/strain. In-vivo analysis was performed using a critical defect model in 23 mice over an 8 week period. Bone formation was assessed using microCT and histological analysis. Finally, a computer modelling process was developed to convert patient CT images into surface models, then formatted into 3D-printable scaffolds to fill critical defects. Following EO sterilisation, there was no change in scaffold surface and persistent availability of growth factors. Scaffolds showed adequate porosity for cell migration with mechanical stiffness similar to cancellous bone. Finally, the in vivo murine model demonstrated rapid bone formation with evidence of trabecular remodelling in samples presenting growth factors compared to controls


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_16 | Pages 54 - 54
1 Apr 2013
Cheng TL Valchev P Dehghani F Little DG Schindeler A
Full Access

Introduction. Bone tissue engineering approaches are an emerging strategy to treat bone defects, and commonly involve the delivery of osteogenic cells and/or drugs via a porous scaffold. We have been exploring an alternative injectable approach for drug delivery that would obviate the need for invasive surgery. Hypothesis. Sucrose Acetate Isobutyrate (SAIB) is a sucrose-based ester that is a highly viscous semi-solid. Diluting SAIB with 10–20% ethanol markedly reduces its viscosity, with ethanol diffusing rapidly after in vivo injection. This phase transitioning property makes SAIB an ideal candidate for bone tissue engineering. Materials and methods. The capacity of SAIB to act as a delivery system for recombinant human BMP-2 (rhBMP-2) was tested in a mouse ectopic bone formation model. In this model SAIB was used to deliver 0 to 10μg rhBMP-2. Next, SAIB was compared with porous collagen scaffold used clinically to delivery rhBMP-2 in a head-to-head trial. Commercial SAIB and SAIB produced in-house were also compared. Bone volumes were quantified by μCT. Discussion. Bone was found to form with as little as 2μg rhBMP-2 when delivered with SAIB. Injected SAIB also showed minimal inflammatory response and rapid breakdown, with bone formation occurring between one and two weeks. Conclusion. SAIB was found to be an effective delivery system for rhBMP-2 with translational utility. Future work will be required to examine the upscaling of this delivery system


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_16 | Pages 17 - 17
1 Apr 2013
Giles E Nauth A Lin T Glick M Schemitsch E
Full Access

Introduction. Nonunion is a common and costly fracture outcome. Intricate reciprocity between angiogenesis and osteogenesis means vascular cell-based therapy offers a novel approach to stimulating bone regeneration. Hypothesis. The current study compared early and late outgrowth endothelial progenitor cell subtypes (EPCs vs OECs) for fracture healing potential in vitro and in vivo. Methods. Primary cell cultures were isolated and characterized by endothelial assays, immunosorbent assays, and multi-color flow cytometry. Co-cultures of EPC subtypes with/without primary osteoblasts (pObs) were analyzed for tube length and connectivity. In vivo, EPCs or OECs (1×10. 6. ) seeded on a gelfoam scaffold were implanted in a rat model of nonunion. Radiography was used to monitor callus formation. Results. OECs expressed more BMP-2 and less VEGF than EPCs (p<0.05). Analysis of surface markers showed decreased CD34+/CD133+/Flk-1+, CD133+ and CD45+ populations in OECs while CD34+/CD31+/Flk-1+ cells increased. pObs significantly inhibited the strong tubulogenesis of OECs while enhancing connectivity and sprout length of EPCs. In vivo, 0/6 scaffold-control and 1/5 OEC rats achieved union at 10 weeks. In comparison, all EPC rats achieved full or partial union. Discussion and Conclusion. Despite favorable tubulogenic and osteoconductive profiles of OECs, EPCs display enhanced fracture healing in vivo. Differences in CXCR4 expression and cell-mediated effects may contribute to this result


The Bone & Joint Journal
Vol. 102-B, Issue 12 | Pages 1723 - 1734
1 Dec 2020
Fung B Hoit G Schemitsch E Godbout C Nauth A

Aims

The purpose of this study was to: review the efficacy of the induced membrane technique (IMT), also known as the Masquelet technique; and investigate the relationship between patient factors and technique variations on the outcomes of the IMT.

Methods

A systematic search was performed in CINAHL, The Cochrane Library, Embase, Ovid MEDLINE, and PubMed. We included articles from 1 January 1980 to 30 September 2019. Studies with a minimum sample size of five cases, where the IMT was performed primarily in adult patients (≥ 18 years old), in a long bone were included. Multivariate regression models were performed on patient-level data to determine variables associated with nonunion, postoperative infection, and the need for additional procedures.


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 12 | Pages 1617 - 1622
1 Dec 2008
Axelrad TW Steen B Lowenberg DW Creevy WR Einhorn TA

Heterotopic ossification occurring after the use of commercially available bone morphogenetic proteins has not been widely reported. We describe four cases of heterotopic ossification in patients treated with either recombinant bone morphogenetic protein 2 or recombinant bone morphogenetic protein 7. We found that while some patients were asymptomatic, heterotopic ossification which had occurred around a joint often required operative excision with good results.


Bone & Joint Research
Vol. 1, Issue 8 | Pages 174 - 179
1 Aug 2012
Alfieri KA Forsberg JA Potter BK

Heterotopic ossification (HO) is perhaps the single most significant obstacle to independence, functional mobility, and return to duty for combat-injured veterans of Operation Enduring Freedom and Operation Iraqi Freedom. Recent research into the cause(s) of HO has been driven by a markedly higher prevalence seen in these wounded warriors than encountered in previous wars or following civilian trauma. To that end, research in both civilian and military laboratories continues to shed light onto the complex mechanisms behind HO formation, including systemic and wound specific factors, cell lineage, and neurogenic inflammation. Of particular interest, non-invasive in vivo testing using Raman spectroscopy may become a feasible modality for early detection, and a wound-specific model designed to detect the early gene transcript signatures associated with HO is being tested. Through a combined effort, the goals of early detection, risk stratification, and development of novel systemic and local prophylaxis may soon be attainable.


The Bone & Joint Journal
Vol. 95-B, Issue 5 | Pages 583 - 597
1 May 2013
Kurien T Pearson RG Scammell BE

We reviewed 59 bone graft substitutes marketed by 17 companies currently available for implantation in the United Kingdom, with the aim of assessing the peer-reviewed literature to facilitate informed decision-making regarding their use in clinical practice. After critical analysis of the literature, only 22 products (37%) had any clinical data. Norian SRS (Synthes), Vitoss (Orthovita), Cortoss (Orthovita) and Alpha-BSM (Etex) had Level I evidence. We question the need for so many different products, especially with limited published clinical evidence for their efficacy, and conclude that there is a considerable need for further prospective randomised trials to facilitate informed decision-making with regard to the use of current and future bone graft substitutes in clinical practice.

Cite this article: Bone Joint J 2013;95-B:583–97.