Advertisement for orthosearch.org.uk
Results 1 - 2 of 2
Results per page:
Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_13 | Pages 63 - 63
7 Aug 2023
Kumar D Agarwal A Kushwaha N
Full Access

Abstract. Purpose. Since arthroscopic reconstruction of the anterior cruciate ligament (ACL) started, the use of peroneus longus grafts for primary ACL reconstruction (ACLR) was never thought of as there is very scant literature on it. So, our study aims to compare the functional outcome and complications in patients with ACL injury managed by ACLR with peroneus longus tendon (PLT) and hamstring tendons (HT) respectively. Materials and Methods. Patients with 16–50 years of either gender presenting with symptomatic ACL deficiency were admitted for arthroscopic single bundle ACLR and allocated into two groups (PLT and HT) operated and observed. Functional scores (IKDC and Lysholm score), clinical knee evaluation, donor site morbidity (AOFAS score) and thigh circumference were recorded preoperatively and at six months, one year post-operatively. The same post-op rehabilitation protocol was followed in both groups. Results. 194 patients (hamstring n=96, peroneus n=98) met the inclusion criteria. There were no significant differences between the pre-op, six months post-op and one-year postoperative score between the hamstring and peroneus longus groups in the IKDC (p=0.356) and Lysholm knee score (p=0.289). The mean for the AOFAS was 99.05±3.56 and 99.80±0.70 in the PLT and HT group respectively showing no statistical difference, with a significant improvement in thigh muscle wasting among the PLT group at final follow-up (p<0.001). Conclusion. We observed similar knee stability, functional outcome and no obvious donor site morbidity among both groups and recommend that a PL graft may be a safe, effective, and viable option for arthroscopic single bundle ACL reconstruction


The Bone & Joint Journal
Vol. 99-B, Issue 1 | Pages 59 - 65
1 Jan 2017
Krause F Barandun A Klammer G Zderic I Gueorguiev B Schmid T

Aims

To assess the effect of high tibial and distal femoral osteotomies (HTO and DFO) on the pressure characteristics of the ankle joint.

Materials and Methods

Varus and valgus malalignment of the knee was simulated in human cadaver full-length legs. Testing included four measurements: baseline malalignment, 5° and 10° re-aligning osteotomy, and control baseline malalignment. For HTO, testing was rerun with the subtalar joint fixed. In order to represent half body weight, a 300 N force was applied onto the femoral head. Intra-articular sensors captured ankle pressure.