There are a number of classification systems for intracapsular fractures of the proximal femur, but none has been shown to be practical with satisfactory reproducibility and accurate predictive value. We have investigated the
Interobserver reliability of the AO system of classification of fractures of the distal radius was assessed using plain radiographs and CT. Five observers classified 30 Colles’-type fractures using only plain radiographs; two months later they were reclassified using CT in addition. Interobserver reliability was poor in both series when detailed classification was used. By reducing the categories to five, interobserver reliability was slightly improved, but was still poor. When only two AO types were used, the reliability was moderate using plain radiographs and good to excellent with the addition of CT. The use of CT as well as plain radiographs brings interobserver reliability to a good level in assessment of the presence or absence of articular involvement, but is otherwise of minor value in improving the interobserver reliability of the AO system of classification of fractures of the distal radius.
We sought to quantify agreement by different assessors of the
In this study, we describe a morphological classification
for greater tuberosity fractures of the proximal humerus. We divided
these fractures into three types: avulsion, split and depression.
We retrospectively reviewed all shoulder radiographs showing isolated
greater tuberosity fractures in a Level I trauma centre between
July 2007 and July 2012. We identified 199 cases where records and
radiographs were reviewed and included 79 men and 120 women with
a mean age of 58 years (23 to 96). The morphological classification
was applied to the first 139 cases by three reviewers on two occasions
using the Kappa statistic and compared with the AO and Neer classifications.
The inter- and intra-observer reliability of the morphological classification
was 0.73 to 0.77 and 0.69 to 0.86, respectively. This was superior
to the Neer (0.31 to 0.35/0.54 to 0.63) and AO (0.30 to 0.32/0.59
to 0.65) classifications. The distribution of avulsion, split and
depression type fractures was 39%, 41%, and 20%, respectively. This
classification of greater tuberosity fractures is more reliable
than the Neer or
INTRODUCTION. Short femoral nail is the most popular instrumentation for femoral trochanteric fractures. PFNA is in widely use and good results are reported. In these papers, fracture classification and evaluation of surgical results were based on plain X-ray. However, some cases of delayed union, non-union, and blade cut out showed no critical problems in immediate postoperative X-ray. Cause of these complications was not able to solve in X-ray analysis. CT scan provides more information about fracture pattern and position of nail and blade. CT analysis is likely to solve the cause of these complications. MATERIALS & METHODS. 20 cases of 36 femoral trochanteric fractures treated with PFNA-II were evaluated by CT scan (pre and post surgery). Four males and 16 females, and average age at surgery was 80.5 (65–100). Eleven cases were A1 fracture and 9 cases were A2 fracture in
There is much debate regarding the use of continuous-compartment-pressure-monitoring (CCM) in the diagnosis of acute compartment syndrome (ACS). We retrospectively reviewed the management of all patients (aged 15 and over) who were admitted with a fracture of the tibial diaphysis, across 3 centres, during 2013–2015. Patient demographics, pre-existing medical problems, initial treatment, subsequent complications, methods of compartment monitoring, and follow-up were all included in the data collection. We separated patients into monitored (MG) and non-monitored groups (NMG), and compared the outcomes of their treatment. Data analysis was performed using SPSS and statistical significance was set as p < 0.05. 287 patients were included in this study (116 NMG vs. 171 MG). There were no significant differences observed in age, sex, previous medical problems, length of stay,
Several previously identified patient-, injury-, and treatment-related factors are associated with the development of nonunion in distal femur fractures. However, the predictive value of these factors is not well defined. We aimed to assess the predictive ability of previously identified risk factors in the development of nonunion leading to secondary surgery in distal femur fractures. We conducted a retrospective cohort study of adult patients with traumatic distal femur fracture treated with lateral locking plate between 2009 and 2018. The patients who underwent secondary surgery due to fracture healing problem or plate failure were considered having nonunion. Background knowledge of risk factors of distal femur fracture nonunion based on previous literature was used to form an initial set of variables. A logistic regression model was used with previously identified patient- and injury-related variables (age, sex, BMI, diabetes, smoking, periprosthetic fracture, open fracture, trauma energy, fracture zone length, fracture comminution, medial side comminution) in the first analysis and with treatment-related variables (different surgeon-controlled factors, e.g. plate length, screw placement, and proximal fixation) in the second analysis to predict the nonunion leading to secondary surgery in distal femur fractures.Aims
Methods
Introduction. Sacral fractures were previously treated with transiliac bars, sacroiliac screws or posterior plates. Sacroiliac screws are not as invasive, but the risk of intra-operative neurovascular damage must be considered. Posterior plate fixation is slightly invasive. In 2006, we conceived a new fixation method with spinal instrumentation system, and I will introduce it. Procedure. We make 5cm skin incisions just above each side of post. sup. spine of ilium and make a tunnel under the soft tissue. Then, we insert 4 screws to ilium, pass two rods through the tunnel and fix them. If needed we make reduction or compression. Finally, set the transvers connecting device on both sides. Material and Method. We indicate this method for type C1 and C2 sacral fracture on
Pneumatic tourniquets are often used during the surgical treatment of unstable traumatic ankle fractures. The aim of this study was to assess the risk of reoperation after open reduction and internal fixation of ankle fractures with and without the use of pneumatic tourniquets. This was a population-based cohort study using data from the Danish Fracture Database with a follow-up period of 24 months. Data were linked to the Danish National Patient Registry to ensure complete information regarding reoperations due to complications, which were divided into major and minor. The relative risk of reoperations for the tourniquet group compared with the non-tourniquet group was estimated using Cox proportional hazards modelling.Aims
Methods
Objective. We reviewed clinical results with minimally invasive method and using a new developed plate for unstable pelvic ring fractures, especially vertically unstable sacral fractures. Materials & Methods. Between 2002 and 2010, 35 patients with vertically unstable sacral fractures were treated with minimally invasive method and using an M-Shaped transiliac plate which was developed by the author. This plate is anatomically designed for posterior pelvic ring, and achieved rigid fixation. Patients included 19 male and 16 female, with the mean age of 46.2 (range, 17∼79) years old. According to the
To investigate if preoperative CT improves detection of unstable trochanteric hip fractures. A single-centre prospective study was conducted. Patients aged 65 years or older with trochanteric hip fractures admitted to Stavanger University Hospital (Stavanger, Norway) were consecutively included from September 2020 to January 2022. Radiographs and CT images of the fractures were obtained, and surgeons made individual assessments of the fractures based on these. The assessment was conducted according to a systematic protocol including three classification systems (AO/Orthopaedic Trauma Association (OTA), Evans Jensen (EVJ), and Nakano) and questions addressing specific fracture patterns. An expert group provided a gold-standard assessment based on the CT images. Sensitivities and specificities of surgeons’ assessments were estimated and compared in regression models with correlations for the same patients. Intra- and inter-rater reliability were presented as Cohen’s kappa and Gwet’s agreement coefficient (AC1).Aims
Methods
Fracture classification of femoral trochanteric fracture is usually based on plain X-ray. However, complications such as delayed union, non-union, and cut out are seen in stable fracture on X-ray. In this study, fracture was classified by 3D-CT and relationship to X-ray classification was investigated. 48 femoral trochanteric fractures (15 males, 33 female, average age: 82.6) treated with PFNA-II were investigated. Fracture was classified to 2part, 3part(5 subgroups), and 4part with combination of 4 fragments in CT; Head (H), Greater trochanter (G), Lesser trochanter (L), and Shaft (S). 5 subgroups of 3 part fracture were (1) H+G (S: small fragment) + L-S, (2) H + G (B:big fragment) + L-S, (3) H + G-L + S, (4) H + G (W:whole) + S, and (5) H + L + G-S. Numbers of each group were as follows; 2 part: 11, 3 part (1) : 7, 3 part (2) : 12, 3 part (3) : 10, 3 part (4) : 2, 3 part (5) : 3, 4 part : 3. 3 part (3), (4), (5) and 4 part are considered as unstable, however, 6 cases in these groups were classified in A1–1 or A1–2 stable fracture in
This study aimed to compare mortality in trochanteric AO/OTA A1 and A2 fractures treated with an intramedullary nail (IMN) or sliding hip screw (SHS). The primary endpoint was 30-day mortality, with secondary endpoints at 0 to 1, 2 to 7, 8 to 30, 90, and 365 days. We analyzed data from 26,393 patients with trochanteric AO/OTA A1 and A2 fractures treated with IMNs (n = 9,095) or SHSs (n = 17,298) in the Norwegian Hip Fracture Register (January 2008 to December 2020). Exclusions were made for patients aged < 60 years, pathological fractures, pre-2008 operations, contralateral hip fractures, fractures other than trochanteric A1/A2, and treatments other than IMNs or SHSs. Kaplan-Meier and Cox regression analyses adjusted for type of fracture, age, sex, cognitive impairment, American Society of Anesthesiologists (ASA) grade, and time period were conducted, along with calculations for number needed to harm (NNH).Aims
Methods
Background. Distal tibial metaphyseal fractures pose many complexities. This study assessed the outcomes of distal tibial fractures treated with percutaneously inserted medial locking plates. Methods. Eighteen patients were selected based on the fracture pattern and classified using the
PURPOSE. To evaluate the late radiographic and functional complications occurring after treatment of reverse oblique trochanteric fractures with the proximal femoral nail. PATIENTS. This is a retrospective study which was conducted between October 2004 and October 2009. 55 patients with a reverse oblique trochanteric fracture were treated with the Gamma 3 nail. According to the
Proper preoperative planning benefits fracture reduction, fixation, and stability in tibial plateau fracture surgery. We developed and clinically implemented a novel workflow for 3D surgical planning including patient-specific drilling guides in tibial plateau fracture surgery. A prospective feasibility study was performed in which consecutive tibial plateau fracture patients were treated with 3D surgical planning, including patient-specific drilling guides applied to standard off-the-shelf plates. A postoperative CT scan was obtained to assess whether the screw directions, screw lengths, and plate position were performed according the preoperative planning. Quality of the fracture reduction was assessed by measuring residual intra-articular incongruence (maximum gap and step-off) and compared to a historical matched control group.Aims
Methods
Introduction. The purpose of the present study was to identify risk factors for lag-screw cut-out following osteosynthesis of intertrochanteric fractures. Materials and methods. The study was a case-control study using a sex and age matched control group. The fractures were classified according to Evans and OTA/
Though most humeral shaft fractures heal nonoperatively, up to one-third may lead to nonunion with inferior outcomes. The Radiographic Union Score for HUmeral Fractures (RUSHU) was created to identify high-risk patients for nonunion. Our study evaluated the RUSHU’s prognostic performance at six and 12 weeks in discriminating nonunion within a significantly larger cohort than before. Our study included 226 nonoperatively treated humeral shaft fractures. We evaluated the interobserver reliability and intraobserver reproducibility of RUSHU scoring using intraclass correlation coefficients (ICCs). Additionally, we determined the optimal cut-off thresholds for predicting nonunion using the receiver operating characteristic (ROC) method.Aims
Methods
Between 1995 and 2000, 19 consecutive patients with fractures of the distal humerus were treated by primary total elbow replacement using the Coonrad-Morrey prosthesis. No patient had inflammatory or degenerative arthritis of the elbow. The mean age at the time of injury was 73 years (61 to 95). According to the
Understanding of open fracture management is skewed due to reliance on small-number lower limb, specialist unit reports and large, unfocused registry data collections. To address this, we carried out the Open Fracture Patient Evaluation Nationwide (OPEN) study, and report the demographic details and the initial steps of care for patients admitted with open fractures in the UK. Any patient admitted to hospital with an open fracture between 1 June 2021 and 30 September 2021 was included, excluding phalanges and isolated hand injuries. Institutional information governance approval was obtained at the lead site and all data entered using Research Electronic Data Capture. Demographic details, injury, fracture classification, and patient dispersal were detailed.Aims
Methods