Aims. Despite limited clinical scientific backing, an additional trochanteric stabilizing plate (TSP) has been advocated when treating unstable trochanteric fractures with a sliding hip screw (SHS). We aimed to explore whether the TSP would result in less post operative fracture motion, compared to SHS alone. Methods. Overall, 31 patients with
Aims. This study aimed to compare mortality in trochanteric
We evaluated the impact of stereo-visualisation of three-dimensional volume-rendering CT datasets on the inter- and intraobserver reliability assessed by kappa values on the
Purpose: To evaluate the intra and inter-observer variation of the Schatzker and
Background. Current literature of definition, classification and outcomes of fractures of talar body remains controversial. Our primary purpose is to present an unusual combination of fractures of talar body with pantalar involvement / dislocation / extension as a basis for modification of Müller
Aims. To investigate if preoperative CT improves detection of unstable trochanteric hip fractures. Methods. A single-centre prospective study was conducted. Patients aged 65 years or older with trochanteric hip fractures admitted to Stavanger University Hospital (Stavanger, Norway) were consecutively included from September 2020 to January 2022. Radiographs and CT images of the fractures were obtained, and surgeons made individual assessments of the fractures based on these. The assessment was conducted according to a systematic protocol including three classification systems (AO/Orthopaedic Trauma Association (OTA), Evans Jensen (EVJ), and Nakano) and questions addressing specific fracture patterns. An expert group provided a gold-standard assessment based on the CT images. Sensitivities and specificities of surgeons’ assessments were estimated and compared in regression models with correlations for the same patients. Intra- and inter-rater reliability were presented as Cohen’s kappa and Gwet’s agreement coefficient (AC1). Results. We included 120 fractures in 119 patients. Compared to radiographs, CT increased the sensitivity of detecting unstable trochanteric fractures from 63% to 70% (p = 0.028) and from 70% to 76% (p = 0.004) using
Introduction: The
Open reduction and internal fixation using plate osteosynthesis for midshaft clavicle fractures is often associated with hardware prominance. Although clinical studies have suggested a role for the use of thinner 2.7mm plates as a means of increasing cosmetic acceptability this still remains an area of controversy. We investigated the effect of plate size (2.7mm vs. 3.5mm), plate treatment (annealed vs. cold worked) and number of screws on the stiffness and yield point. Twenty-four synthetic clavicles were randomly divided into four treatment groups - Synthes (Synthes, Paoli, PA) 2.7mm cold-worked calcaneal reconstruction plate with six or eight bicortical screws; 3.5mm LCP reconstruction plate (RP) and 3.5mm LCP pre-contoured superior-anterior clavicle plate (PCSA). After measuring the baseline stiffness of the intact specimens, all clavicles were plated, a wedge-shaped inferior defect was created and testing performed using a cantilever-bending model. Statistical analysis was performed using one-way ANOVA with Tukey's multiple comparison test with significance set at a P value <0.05.Background
Methods
Controversy exists whether to treat unstable pertrochanteric hip fractures with either intra-medullary or extra-medullary devices. A prospective randomised control trial was performed to compare the outcome of unstable pertrochanteric hip fractures stabilised with either a sliding hip screw or long Gamma Nail. The hypothesis was that there is no difference in outcome between the two modes of treatment. Over a four year period, 210 patients presenting with an unstable pertrochanteric hip fracture (AO/OTA 31 A2) were recruited into the study. Eligible patients were randomised on admission to either long Gamma Nail or sliding hip screw. Follow-up was arranged for three, six, and twelve months. Primary outcome measures were implant failure or ‘cut-out’. Secondary measures included mortality, length of hospital stay, transfusion rate, change in mobility and residence, and EuroQol outcome score. Five patients required revision surgery for implant cut-out (2.5%), of which three were long Gamma Nails and two were sliding hip screws (no significant difference). There were no incidences of implant failure or deep infection. Tip apex distance was found to correlate with implant cut-out. There was no statistically significant difference in either the EuroQol outcome scores or mortality rates between the two groups when corrected for mini mental score. There was no difference in transfusion rates, length of hospital stay, and change in mobility or residence. There was a clear cost difference between the implants. The sliding hip screw remains the gold standard in the treatment of unstable pertrochanteric fractures of the proximal femur.
Aims. This study evaluates risk factors influencing fracture characteristics for postoperative periprosthetic femoral fractures (PFFs) around cemented stems in total hip arthroplasty. Methods. Data were collected for PFF patients admitted to eight UK centres between 25 May 2006 and 1 March 2020. Radiographs were assessed for Unified Classification System (UCS) grade and
With an aging population and increase in total knee arthroplasty, periprosthetic distal femur fractures (PDFFs) have increased. The differences between these fractures and native distal femur fractures (NDFF) have not been comprehensively investigated. The purpose of this study was to compare the demographic, fracture, and treatment details of PDFFs compared to NDFFs. A retrospective study of patients ≥ 18 years old who underwent surgical treatment for either a NDFF or a PDFF from 2010 to 2020 at a level 1 trauma center was performed. Demographics,
Treatment of both simple and complex patella fractures is a challenging clinical problem. The aim of this study was to investigate the biomechanical performance of recently developed lateral rim variable angle locking plates versus tension band wiring used for fixation of simple and complex patella fractures. Twelve pairs of human anatomical knees were used to simulate either two-part transverse simple
Treatment of simple and complex patella fractures represents a challenging clinical problem. Controversy exists regarding the most appropriate fixation method. Tension band wiring, aiming to convert the pulling forces on the anterior aspect of the patella into compression forces across the fracture site, is the standard of care, however, it is associated with high complication rates. Recently, anterior variable-angle locking plates have been developed for treatment of simple and comminuted patella fractures. The aim of this study was to investigate the biomechanical performance of the novel anterior variable-angle locking plates versus tension band wiring used for fixation of simple and complex patella fractures. Sixteen pairs of human cadaveric knees were used to simulate either two-part transverse simple
Aims. The aim of this study was to compare the functional and radiological outcomes and the complication rate after nail and plate fixation of unstable fractures of the ankle in elderly patients. Methods. In this multicentre study, 120 patients aged ≥ 60 years with an acute unstable
Aims. To compare operative and nonoperative treatment for displaced distal radius fractures in patients aged over 65 years. Methods. A total of 100 patients were randomized in this non-inferiority trial, comparing cast immobilization with operation with a volar locking plate. Patients with displaced
To conduct a meta-analysis for intertrochanteric hip fractures comparing in terms of efficacy and safety short versus long intralomedullary nails. A pubmed search of the last 10 years for intertrochanteric fracture 31A1-31A3 according to the
The lateral wall thickness (LWT) in trochanteric femoral fractures is a known predictive factor for postoperative fracture stability. Currently, the
Lag screw cut-out is a serious complication of dynamic hip screw fixation in trochanteric hip fractures. Lag screw position is recognised as a crucial factor influencing the occurrence of lag screw cut-out. We propose a modification of the Tip Apex Distance (TAD) and hypothesize that it could enhance the reliability of predicting lag screw cut-out in these injuries. A retrospective study of hip fracture cases was conducted from January 2018 to July 2022. A total of 109 patients were eligible for the final analysis. The modified TAD was measured in millimetres, based on the sum of the traditional TAD in the lateral view and the net value of two distances in the anteroposterior (AP) view. The first distance is from the lag screw tip to the opposite point on the femoral head along the lag screw axis, while the second distance is from that point to the femoral head apex. The first distance is a positive value, whereas the second distance is positive if the lag screw is superior and negative if it is inferior. Receiver operating characteristic (ROC) curve analysis was used to assess the reliability of various parameters for evaluating the lag screw position within the femoral head. Factors such as reduction quality, fracture pattern according to the
Introduction. A subset of patients in cast awaiting fixation of ankle fractures require conversion to delayed external fixation (dEF). We aimed to evaluate the effect of delayed versus planned external fixation (pEF), then identify objective characteristics contributing to need for conversion. Method. We extracted data from our booking system to identify all ankle external fixation procedures between 2010 to 2022. Exclusions included open fractures, the skeletally immature, and pilon or talus fractures. Fractures were classified using the
Introduction: The use of intramedullary nailing (IMHS) has increased at the expense of the dynamic hip screw (DHS), although the outcome is not different in the studies of pertrochanteric fractures (PTF), known as