Aims. This study aimed to compare mortality in trochanteric AO/OTA A1 and
Aims. Patients with A1 and A2 trochanteric hip fractures represent a substantial proportion of trauma caseload, and national guidelines recommend that sliding hip screws (SHS) should be used for these injuries. Despite this, intramedullary nails (IMNs) are routinely implanted in many hospitals, at extra cost and with unproven patient outcome benefit. We have used data from the National Hip Fracture Database (NHFD) to examine the use of SHS and IMN for A1 and
Appropriate surgical management of hip fractures has major clinical and economic consequences. Recently IMN use has increased compared to SHS constructs, despite no clear evidence demonstrating superiority of outcome. We therefore set out to provide further evidence about the clinical and economic implications of implant choice when considering hip fracture fixation strategies. A retrospective cohort study using Scottish hip fracture audit (SHFA) data was performed for the period 2016–2022. Patients ≥50 with a hip fracture and treated with IMN or SHS constructs at Scottish Hospitals were included. Comparative analyses, including adjustment for confounders, were performed utilising Multivariable logistic regression for dichotomous outcomes and Mann-Whitney-U tests for non-parametric data. A sub-group analysis was also performed focusing on AO-A1/A2 configurations which utilised additional regional data. Cost differences in Length of Stay (LOS) were calculated using defined costs from the NHS Scotland Costs book. In all analyses p<0.05 denoted significance. 13638 records were included (72% female). 9867 received a SHS (72%). No significant differences were identified in 30 or 60-day survival (Odds Ratio [OR] 1.05, 95%CI 0.90–1.23; p=0.532), (OR 1.10, 95%CI 0.97–1.24; p=0.138) between SHS and IMN's. There was however a significantly lower early mobilisation rate with IMN vs SHS (OR 0.64, 95%CI 0.59–0.70; p<0.001), and lower likelihood of discharge to domicile by day-30 post-admission (OR 0.77, 95%CI 0.71–0.84; p<0.001). Acute and overall, LOS were significantly lower for SHS vs IMN (11 vs 12 days and 20 vs 24 days respectively; p<0.001). Findings were similar across a sub-group analysis of 559 AO A1/
Aims. This study evaluated variation in the surgical treatment of stable (A1) and unstable (A2) trochanteric hip fractures among an international group of orthopaedic surgeons, and determined the influence of patient, fracture, and surgeon characteristics on choice of implant (intramedullary nailing (IMN) versus sliding hip screw (SHS)). Methods. A total of 128 orthopaedic surgeons in the Science of Variation Group evaluated radiographs of 30 patients with Type A1 and A2 trochanteric hip fractures and indicated their preferred treatment: IMN or SHS. The management of Type A3 (reverse obliquity) trochanteric fractures was not evaluated. Agreement between surgeons was calculated using multirater kappa. Multivariate logistic regression models were used to assess whether patient, fracture, and surgeon characteristics were independently associated with choice of implant. Results. The overall agreement between surgeons on implant choice was fair (kappa = 0.27 (95% confidence interval (CI) 0.25 to 0.28)). Factors associated with preference for IMN included USA compared to Europe or the UK (Europe odds ratio (OR) 0.56 (95% CI 0.47 to 0.67); UK OR 0.16 (95% CI 0.12 to 0.22); p < 0.001); exposure to IMN only during training compared to surgeons that were exposed to both (only IMN during training OR 2.6 (95% CI 2.0 to 3.4); p < 0.001); and A2 compared to A1
The lateral wall thickness (LWT) in trochanteric femoral fractures is a known predictive factor for postoperative fracture stability. Currently, the AO/OTA classification uses a patient non-specific measure to assess the absolute LWT (aLWT) and distinguish stable A1.3 from unstable
Objectives. Distal humerus fractures in elderly population are often comminuted and presents multiple challenges. When managed with fixation the results are often complicated with stiffness, pain, and reduced function while total elbow replacement is fraught with lifelong restrictions on load bearing which can significantly affect elderly patients who rely assistive devices for ambulation. Elbow hemiarthroplasty however, presents a viable alternative in these cases. This series evaluates the results of the distal humerus hemiarthroplasty in a single centre. Designs and methods. Data was collected retrospectively. Comprehensive case reviews were done to collect demographic, intra-operative and post-operative data. Fractures were classified as per AO classification. The primary outcome was functional outcome and range of motion (ROM). The secondary outcomes were complications and patient satisfaction. Results. 22 cases were included in this study from 2016 – 2023 majority being females (n=18). Mean age was 74years (SD −11.2). Majority fractures were AO type C3 (n=15) with two
Purpose. To evaluate outcome after cementless bipolar hemiarthroplasties using a standard(tapered, rectangular) stem for the treatment of above type
Introduction: Loss of the cervical lordosis is a common finding on the emergency department in patients who have been involved in a car accident as well as in those who have suffered head and neck injury. The difficult circumstances, under which the plain films are usually taken, make the use of CT indispensable. Our study presents the CT findings from the cervical spine in patients with loss of the cervical lordosis. Method-Patients We studied 120 patients from February 2003 to January 2004. Their mean age was 37 years old. Our protocol included the lateral-AP view, while in the absence of findings, except loss of cervical lordosis, from the plain films, the patients underwent spiral CT within 24 h. Results: Fractures of the cervical spine were found in 7 patients (5,8%). In 5 of them these involved the A1–A2 level. In two patients fractures of the occipital condyles were found. One A7 fracture coexisted with an
INTRODUCTION. Short femoral nail is the most popular instrumentation for femoral trochanteric fractures. PFNA is in widely use and good results are reported. In these papers, fracture classification and evaluation of surgical results were based on plain X-ray. However, some cases of delayed union, non-union, and blade cut out showed no critical problems in immediate postoperative X-ray. Cause of these complications was not able to solve in X-ray analysis. CT scan provides more information about fracture pattern and position of nail and blade. CT analysis is likely to solve the cause of these complications. MATERIALS & METHODS. 20 cases of 36 femoral trochanteric fractures treated with PFNA-II were evaluated by CT scan (pre and post surgery). Four males and 16 females, and average age at surgery was 80.5 (65–100). Eleven cases were A1 fracture and 9 cases were
The aim of this study was to investigate if there are differences in outcome between sliding hip screws (SHSs) and intramedullary nails (IMNs) with regard to fracture stability. We assessed data from 17,341 patients with trochanteric or subtrochanteric fractures treated with SHS or IMN in the Norwegian Hip Fracture Register from 2013 to 2019. Primary outcome measures were reoperations for stable fractures (AO Foundation/Orthopaedic Trauma Association (AO/OTA) type A1) and unstable fractures (AO/OTA type A2, A3, and subtrochanteric fractures). Secondary outcome measures were reoperations for A2, A3, and subtrochanteric fractures individually, one-year mortality, quality of life (EuroQol five-dimension three-level index score), pain (visual analogue scale (VAS)), and satisfaction (VAS) for stable and unstable fractures. Hazard rate ratios (HRRs) for reoperation were calculated using Cox regression analysis with adjustments for age, sex, and American Society of Anesthesiologists score.Aims
Methods
Aim: Unstable lateral fractures of the proximal femur (type A2 and A3 of AO classiþcation) present a controversial problem for surgical treatment, due to the difþculty to achieve an adequate mechanically stable bone-device system, so to allow an early weight-bearing. To improve the stability of bone-device complex, a trochanteric stabilizing plate (TSP) has been introduced. The properties of TSP is to avoid shaft medialization in the postoperative. The aim of our study was report results of surgical treatment of unstable trochanteric fractures using a dynamic hip screws in association with TSP. Methods: From January 2000 to March 2002, 51 patients affected by this kind of
Our purpose is to use radiographs to compare callus formation with two types of intramedullary nailing for femoral shaft fractures: reamed interlocking (IL) and Ender nails. Femoral shaft type A fractures according to AO classification were studied. From 1991 to 1995, 27 patients with 27 fractures were treated with reamed IL nailing and 79 patients with 81 fractures were treated with Ender nailing. IL group included with an average of 22 (range, 16–28) years, and the Ender group included with an average of 28 (range, 15–72) years. Patients had been followed for an average of 1.8 (range, 1–2.8) years after surgery. In all cases of IL group, the femoral canal was reamed. For type A3 fractures, an interlocking screw was inserted only at the distal site. For type A1 and
In a prospective, consecutive study we reviewed the results of 32 supracondylar femoral fractures treated by Smith &
Nephew intramedullary supracondylar nailing between January 1996 and October 2002. The mean age of 23 women and nine men was 67 (58 to 89). All fractures were closed. Two patients had associated upper limb fractures. In four cases, fractures occurred around total knee prostheses. Four patients had previously undergone ipsilateral total hip replacement or had had a sliding hip screw. On the AO classification the majority of fractures were type-33A1 and
Aims: The pourpose of this study is to review a series of A2 intertrochanteric fractures in old, obese osteoporotic patients treated by total hip arthroplasty. Methods: 52 patients with A2 intertrochanteric fracture aged ≥ 75 years, mentally healthy, with BMD lower than 2.5 T score and Body Mass Index ≥30 were selected. They were 40 female and 12 males, aged 82±5 years with Body Mass Index of 32±2. Through a Hardinge approach to the hip, the femoral head was removed and a cemented cup and stem were implanted. Then the greater trochanter fragments were fixed by cerclage. The lesser trochanter fragment was not fixed. Medius gluteus muscle fibers were sutured to the greater trochanter and to the vastus lateralis muscle. All patients were allowed weight bearing as soon as possible after surgery. Results: No surgical complications were observed. Average Harris Hip Score at 1 month was 63±9 at 3 months 77±6 and at 1 year 78±7, at 5 years follow up 76±14 in the 24 patients still alive. None of the other died for causes related to the interthrocanteric fracture. Average return to normal daily activity time was 27±5 days. Conclusions: Total hip arthroplasty is a safe procedure for treatment of old, obese osteoporotic patients affected by
The aim of this paper is to review the evidence relating to the
anatomy of the proximal femur, the geometry of the fracture and
the characteristics of implants and methods of fixation of intertrochanteric
fractures of the hip. Relevant papers were identified from appropriate clinical databases
and a narrative review was undertaken.Aims
Materials and Methods
Although the importance of lateral femoral wall
integrity is increasingly being recognised in the treatment of intertrochanteric
fracture, little attention has been put on the development of a
secondary post-operative fracture of the lateral wall. Patients
with post-operative fractures of the lateral wall were reported
to have high rates of re-operation and complication. To date, no
predictors of post-operative lateral wall fracture have been reported.
In this study, we investigated the reliability of lateral wall thickness
as a predictor of lateral wall fracture after dynamic hip screw
(DHS) implantation. A total of 208 patients with AO/OTA 31-A1 and -A2 classified
intertrochanteric fractures who received internal fixation with
a DHS between January 2003 and May 2012 were reviewed. There were
103 men and 150 women with a mean age at operation of
78 years (33 to 94). The mean follow-up was 23 months (6 to 83).
The right side was affected in 97 patients and the left side in
111. Clinical information including age, gender, side, fracture
classification, tip–apex distance, follow-up time, lateral wall
thickness and outcome were recorded and used in the statistical
analysis. Fracture classification and lateral wall thickness significantly
contributed to post-operative lateral wall fracture (both p <
0.001). The lateral wall thickness threshold value for risk of developing
a secondary lateral wall fracture was found to be 20.5 mm. To our knowledge, this is the first study to investigate the
risk factors of post-operative lateral wall fracture in intertrochanteric
fracture. We found that lateral wall thickness was a reliable predictor
of post-operative lateral wall fracture and conclude that intertrochanteric
fractures with a lateral wall thickness <
20.5 mm should not
be treated with DHS alone. Cite this article:
The Sliding Hip Screw (SHS) is commonly used to treat trochanteric hip fractures. Fixation failure is a devastating complication requiring complex revision surgery. One mode of fixation failure is lag screw cut-out which is greatest in unstable fracture patterns and when the tip-apex distance of the lag screw is > 25 mm. The X-Bolt Dynamic Hip Plating System (X-Bolt Orthopaedics, Dublin, Ireland) is a new device which aims to reduce this risk of cut-out. However, some surgeons have reported difficulty minimising the tip-apex distance with subsequent concerns that this may lead to an increased risk of cut-out. We measured the tip-apex distance from the intra-operative radiographs of 93 unstable trochanteric hip fractures enrolled in a randomised controlled trial (Warwick Hip Trauma Evaluation, WHiTE One trial). Participants were treated with either the sliding hip screw or the X-Bolt dynamic hip plating system. We also recorded the incidence of cut-out in both groups, at a median follow-up time of 17 months.Objectives
Patients and Methods
There are various pin-in-plaster methods for treating fractures
of the distal radius. The purpose of this study is to introduce
a modified technique of ‘pin in plaster’. Fifty-four patients with fractures of the distal radius were
followed for one year post-operatively. Patients were excluded if
they had type B fractures according to AO classification, multiple
injuries or pathological fractures, and were treated more than seven
days after injury. Range of movement and functional results were
evaluated at three and six months and one and two years post-operatively.
Radiographic parameters including radial inclination, tilt, and
height, were measured pre- and post-operatively.Objectives
Methods
The aim of this study was to identify patient- and surgery-related
risk factors for sustaining an early periprosthetic fracture following
primary total hip arthroplasty (THA) performed using a double-tapered
cementless femoral component (Bi-Metric femoral stem; Biomet Inc.,
Warsaw, Indiana). A total of 1598 consecutive hips, in 1441 patients receiving
primary THA between January 2010 and June 2015, were retrospectively
identified. Level of pre-operative osteoarthritis, femoral Dorr
type and cortical index were recorded. Varus/valgus placement of
the stem and canal fill ratio were recorded post-operatively. Periprosthetic
fractures were identified and classified according to the Vancouver
classification. Regression analysis was performed to identify risk
factors for early periprosthetic fracture.Aims
Patients and Methods