The authors are not aware of any research comparing computed tomography (CT) and avascular necrosis (AVN) of the scaphoid bone. The primary aim of our study was to investigate the use of longitudinal CT in predicting AVN of the proximal pole of the scaphoid, and subsequent fracture nonunion following internal fixation.

Thirty-two patients operated on by the senior author for scaphoid fracture were included. Preoperative CT scans were independently assessed for deformity, comminution, fracture position, proximal pole sclerosis, and bridging trabeculae. Intra-operative biopsy of the proximal pole was assessed independently by a blinded musculoskeletal histologist. AVN was determined by histology of a proximal pole biopsy, using the criteria described by Ficat. Post-operative CT scan was utilised to determine fracture union.

Preoperative CT features which significantly correlated with AVN were, increased radiodensity of the proximal pole, the absence of any bridging trabeculae comminution, dorsal cortical angle, proximal fracture and age less than 20. Features predictive of subsequent nonunion were fractures of the proximal, increased radiodensity of the proximal pole, and AVN.

Preoperative CT scan findings are significantly correlated with histologically confirmed AVN and fracture union. Preoperative longitudinal CT scan is of significant prognostic value and should be considered to assist in predicting outcome and assessing treatment options.