header advert
Results 1 - 50 of 2094
Results per page:
The Bone & Joint Journal
Vol. 104-B, Issue 4 | Pages 504 - 509
1 Apr 2022
Kennedy JW Farhan-Alanie OM Young D Kelly MP Young PS

Aims. The aim of this study was to assess the clinical and radiological outcomes of an antiprotrusio acetabular cage (APC) when used in the surgical treatment of periacetabular bone metastases. Methods. This retrospective cohort study using a prospectively collected database involved 56 patients who underwent acetabular reconstruction for periacetabular bone metastases or haematological malignancy using a single APC between January 2009 and 2020. The mean follow-up was 20 months (1 to 143). The primary outcome measure was implant survival. Postoperative radiographs were analyzed for loosening and failure. Patient and implant survival were assessed using a competing risk analysis. Secondary parameters included primary malignancy, oncological treatment, surgical factors, length of stay in hospital, and postoperative complications. Results. A total of 33 patients (59%) died during the study period at a mean of 15 months postoperatively (1 to 63). No patient had radiological evidence of loosening or failure. Acetabular component survival was 100%. Three patients (5.4%) had further surgery; one (1.8%) underwent revision of the femoral component for dislocation, one required debridement with implant retention for periprosthetic joint infection, and one required closed reduction for dislocation. Using death as a competing risk, at 100 months, the probability of revision was 0.036 and the risk of death was 0.84. Conclusion. With appropriate patient selection, the antiprotrusio cage offers good implant survival, with a reasonable perioperative complication rate in this high-risk group of patients when managing metastatic disease or haematological malignancy around the acetabulum. Cite this article: Bone Joint J 2022;104-B(4):504–509


The Bone & Joint Journal
Vol. 104-B, Issue 7 | Pages 767 - 774
1 Jul 2022
Nakashima Y Ishibashi S Kitamura K Yamate S Motomura G Hamai S Ikemura S Fujii M

Aims. Although periacetabular osteotomies are widely used for the treatment of symptomatic dysplastic hips, long-term surgical outcomes and patient-reported outcome measures (PROMs) are still unclear. Accordingly, we assessed hip survival and PROMs at 20 years after transpositional osteotomy of the acetabulum (TOA). Methods. A total of 172 hips in 159 patients who underwent TOA were followed up at a mean of 21.02 years (16.6 to 24.6) postoperatively. Kaplan-Meier analysis was used to assess survivorship with an endpoint of total hip arthroplasty (THA). PROMs included the visual analogue scale (VAS) Satisfaction, VAS Pain, Oxford Hip Score (OHS), and Forgotten Joint Score-12 (FJS-12). Thresholds for favourable outcomes for OHS (≥ 42) and FJS-12 (≥ 51) were obtained using the receiver operating characteristic curve with VAS Satisfaction ≥ 50 and VAS Pain < 20 as anchors. Results. THA was performed on 37 hips (21.5%) by the latest follow-up. Kaplan-Meier analysis indicated that the hip survival rate at 20 years was 79.7% (95% confidence interval (CI) 73.7 to 86.3). Multivariate analysis showed that preoperative Tönnis grade significantly influenced hip survival. Tönnis grades 0, 1, and 2 were associated with 20-year survival rates of 93.3% (95% CI 84.8 to 100), 86.7% (95% CI 79.8 to 94.3), and 54.8% (95% CI 41.5 to 72.3), respectively. More than 60% of the patients exhibited favourable PROMs. An advanced Tönnis grade at the latest follow-up and a higher BMI were both significantly associated with unfavourable OHS, but not with other PROMs. Conclusion. This study demonstrated the durability of TOA for hips with Tönnis grades 0 to 1 at 20 years. While the presence of advanced osteoarthritis and higher BMI was associated with lower hip functions (OHS), it was not necessarily associated with worse patient satisfaction and joint awareness. Cite this article: Bone Joint J 2022;104-B(7):767–774


The Bone & Joint Journal
Vol. 106-B, Issue 8 | Pages 783 - 791
1 Aug 2024
Tanaka S Fujii M Kawano S Ueno M Nagamine S Mawatari M

Aims. The aim of this study was to determine the clinical outcomes and factors contributing to failure of transposition osteotomy of the acetabulum (TOA), a type of spherical periacetabular osteotomy, for advanced osteoarthritis secondary to hip dysplasia. Methods. We reviewed patients with Tönnis grade 2 osteoarthritis secondary to hip dysplasia who underwent TOA between November 1998 and December 2019. Patient demographic details, osteotomy-related complications, and the modified Harris Hip Score (mHHS) were obtained via medical notes review. Radiological indicators of hip dysplasia were assessed using preoperative and postoperative radiographs. The cumulative probability of TOA failure (progression to Tönnis grade 3 or conversion to total hip arthroplasty) was estimated using the Kaplan-Meier product-limited method. A multivariate Cox proportional hazards model was used to identify predictors of failure. Results. This study included 127 patients (137 hips). Median follow-up period was ten years (IQR 6 to 15). The median mHHS improved from 59 (IQR 52 to 70) preoperatively to 90 (IQR 73 to 96) at the latest follow-up (p < 0.001). The survival rate was 90% (95% CI 82 to 95) at ten years, decreasing to 21% (95% CI 7 to 48) at 20 years. Fair joint congruity on preoperative hip abduction radiographs and a decreased postoperative anterior wall index (AWI) were identified as independent risk factors for failure. The survival rate for the 42 hips with good preoperative joint congruity and a postoperative AWI ≥ 0.30 was 100% at ten years, and remained at 83% (95% CI 38 to 98) at 20 years. Conclusion. Although the overall clinical outcomes of TOA in patients with advanced osteoarthritis are suboptimal, favourable results can be achieved in selected cases with good preoperative joint congruity and adequate postoperative anterior acetabular coverage. Cite this article: Bone Joint J 2024;106-B(8):783–791


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_15 | Pages 59 - 59
7 Nov 2023
Antoni A Laubscher K Blankson B Berry K Swanepoel S Laubscher M Maqungo S
Full Access

Acetabulum fractures caused by civilian firearms represent a unique challenge for orthopaedic surgeons. Treatment strategies should include the assessment of infection risk due to frequently associated abdominal injuries and maintenance of joint function. Still, internationally accepted treatment algorithms are not available. The aim of the study was to increase knowledge about civilian gunshot fractures of the acetabulum by describing their characteristics and management at a high-volume tertiary hospital. All adult patients admitted to our hospital between January 2009 and December 2022 with civilian gunshot fractures of the acetabulum were included in this descriptive retrospective study. In total our institution treated 301 patients with civilian gunshot fractures of the hip joint and pelvis during the observation period, of which 54 involved the acetabulum. Most patients were young males (88,9%) with a mean age of 29 years. Thirty patients (55,6%) had associated intraabdominal or urological injuries. Fracture patterns were mostly stable fractures with minor joint destruction amenable to conservative fracture treatment (n=48, 88,9%). Orthopaedic surgical interventions were performed in 21 patients (38,9%) with removal of bullets in contact with the hip joint via arthrotomy or surgical hip dislocation as most frequent procedures. Most patients received antibiotics on admission (n=49, 90,7%). Fracture related infections of the acetabulum were noted in six patients (11,1%) while the mortality in the study population was low with one demised patient (1,9%) due to the trauma burden. Most civilian acetabulum gunshot fractures are associated with intraabdominal or urological injuries. In comparison to the literature on extremity gunshot fractures, there is an increased risk of infection in our study population. The decision for surgical wash-out and bullet removal should be based on contamination and anticipated joint destruction, while osteosynthesis or primary arthroplasty are rarely necessary for these injuries


The Bone & Joint Journal
Vol. 106-B, Issue 3 Supple A | Pages 59 - 66
1 Mar 2024
Karunaseelan KJ Nasser R Jeffers JRT Cobb JP

Aims. Surgical approaches that claim to be minimally invasive, such as the direct anterior approach (DAA), are reported to have a clinical advantage, but are technically challenging and may create more injury to the soft-tissues during joint exposure. Our aim was to quantify the effect of soft-tissue releases on the joint torque and femoral mobility during joint exposure for hip resurfacing performed via the DAA. Methods. Nine fresh-frozen hip joints from five pelvis to mid-tibia cadaveric specimens were approached using the DAA. A custom fixture consisting of a six-axis force/torque sensor and motion sensor was attached to tibial diaphysis to measure manually applied torques and joint angles by the surgeon. Following dislocation, the torques generated to visualize the acetabulum and proximal femur were assessed after sequential release of the joint capsule and short external rotators. Results. Following initial exposure, the ischiofemoral ligament (7 to 8 o’clock) was the largest restrictor of exposure of the acetabulum, contributing to a mean 25% of overall external rotational restraint. The ischiofemoral ligament (10 to 12 o’clock) was the largest restrictor of exposure of the proximal femur, contributing to 25% of overall extension restraint. Releasing the short external rotators had minimal contribution in torque generated during joint exposure (≤ 5%). Conclusion. Adequate exposure of both proximal femur and acetabulum may be achieved with minimal torque by performing a full proximal circumferential capsulotomy while preserving short external rotators. The joint torque generated and exposure achieved is dependent on patient factors; therefore, some cases may necessitate further releases. Cite this article: Bone Joint J 2024;106-B(3 Supple A):59–66


The Bone & Joint Journal
Vol. 103-B, Issue 4 | Pages 795 - 803
1 Apr 2021
Fujiwara T Medellin Rincon MR Sambri A Tsuda Y Clark R Stevenson J Parry MC Grimer RJ Jeys L

Aims. Limb salvage for pelvic sarcomas involving the acetabulum is a major surgical challenge. There remains no consensus about what is the optimum type of reconstruction after resection of the tumour. The aim of this study was to evaluate the surgical outcomes in these patients according to the methods of periacetabular reconstruction. Methods. The study involved a consecutive series of 122 patients with a periacetabular bone sarcoma who underwent limb-salvage surgery involving a custom-made prosthesis in 65 (53%), an ice-cream cone prosthesis in 21 (17%), an extracorporeal irradiated autograft in 18 (15%), and nonskeletal reconstruction in 18 (15%). Results. The rates of major complications necessitating further surgery were 62%, 24%, 56%, and 17% for custom-made prostheses, ice-cream cone prostheses, irradiated autografts and nonskeletal reconstructions, respectively (p = 0.001). The ten-year cumulative incidence of failure of the reconstruction was 19%, 9%, 33%, and 0%, respectively. The major cause of failure was deep infection (11%), followed by local recurrence (6%). The mean functional Musculoskeletal Tumour Society (MSTS) scores were 59%, 74%, 64%, and 72%, respectively. The scores were significantly lower in patients with major complications than in those without complications (mean 52% (SD 20%) vs 74% (SD 19%); p < 0.001). For periacetabular resections involving the ilium, the mean score was the highest with custom-made prostheses (82% (SD 10%)) in patients without any major complication; however, nonskeletal reconstruction resulted in the highest mean scores (78% (SD 12%)) in patients who had major complications. For periacetabular resections not involving the ilium, significantly higher mean scores were obtained with ice-cream cone prostheses (79% (SD 17%); p = 0.031). Conclusion. Functional outcome following periacetabular reconstruction is closely associated with the occurrence of complications requiring further surgery. For tumours treated with periacetabular and iliac resection, skeletal reconstruction may result in the best outcomes in the absence of complications, whereas nonskeletal reconstruction is a reasonable option if the risk of complications is high. For tumours requiring periacetabular resection without the ilium, reconstruction using an ice-cream cone prosthesis supported by antibiotic-laden cement is a reliable option. Cite this article: Bone Joint J 2021;103-B(4):795–803


The Bone & Joint Journal
Vol. 105-B, Issue 7 | Pages 743 - 750
1 Jul 2023
Fujii M Kawano S Ueno M Sonohata M Kitajima M Tanaka S Mawatari D Mawatari M

Aims. To clarify the mid-term results of transposition osteotomy of the acetabulum (TOA), a type of spherical periacetabular osteotomy, combined with structural allograft bone grafting for severe hip dysplasia. Methods. We reviewed patients with severe hip dysplasia, defined as Severin IVb or V (lateral centre-edge angle (LCEA) < 0°), who underwent TOA with a structural bone allograft between 1998 and 2019. A medical chart review was conducted to extract demographic data, complications related to the osteotomy, and modified Harris Hip Score (mHHS). Radiological parameters of hip dysplasia were measured on pre- and postoperative radiographs. The cumulative probability of TOA failure (progression to Tönnis grade 3 or conversion to total hip arthroplasty) was estimated using the Kaplan–Meier product-limited method, and a multivariate Cox proportional hazard model was used to identify predictors for failure. Results. A total of 64 patients (76 hips) were included in this study. The median follow-up period was ten years (interquartile range (IQR) five to 14). The median mHHS improved from 67 (IQR 56 to 80) preoperatively to 96 (IQR 85 to 97) at the latest follow-up (p < 0.001). The radiological parameters improved postoperatively (p < 0.001), with the resulting parameters falling within the normal range in 42% to 95% of hips. The survival rate was 95% at ten years and 80% at 15 years. Preoperative Tönnis grade 2 was an independent risk factor for TOA failure. Conclusion. Our findings suggest that TOA with structural bone allografting is a viable surgical option for correcting severely dysplastic acetabulum in adolescents and young adults without advanced osteoarthritis, with favourable mid-term outcomes. Cite this article: Bone Joint J 2023;105-B(7):743–750


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 2 | Pages 257 - 261
1 Feb 2011
Rejholec M

In late developmental dysplasia of the hip in childhood, the deformed dysplastic acetabulum is malaligned and has lost its shape due to pressure from the subluxed femoral head. The outer part of the acetabulum involves the upper part of the original acetabulum, thereby giving a bipartite appearance. A clear edge separates the outer from inner part which represents the lower part of the original acetabulum and has no direct contact with the femoral head. Combined pelvic osteotomy (CPO) using a Lance acetabuloplasty with either a Salter or a Pemberton procedure restores the original shape and realigns the acetabulum. A total of 20 children (22 hips), with a mean age of 46 months (28 to 94) at primary operation underwent CPO with follow-up for between 12 and 132 months. In each case concentric stable reduction with good acetabular cover was achieved and maintained throughout the period of follow-up


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 8 | Pages 1127 - 1133
1 Aug 2005
Cho T Choi IH Chung CY Yoo WJ Lee KS

The bicompartmental acetabulum is one of the morphological changes which may be seen in children with Legg-Calvé-Perthes’ disease. Three-dimensional CT and MRI were used to analyse the detailed morphology of the acetabulum with special reference to its inner surface, in 16 patients with Perthes’ disease and a bicompartmental acetabulum. The bicompartmental appearance was seen on the coronal plane image through the acetabular fossa. The lunate surface was seen to grow laterally resulting in an increased mediolateral thickness of the triradiate cartilage. On the horizontal plane images, the acetabular fossa had deepened and had a distinct prominence at its posterior border. The combination of these morphological changes resulted in a bicompartmental appearance on plain radiography. Acetabular bicompartmentalisation appears to be the result of an imbalance of growth between the cartilage-covered lunate surface and the cartilage-devoid acetabular fossa


The Bone & Joint Journal
Vol. 106-B, Issue 5 Supple B | Pages 74 - 81
1 May 2024
Callary SA Broekhuis D Barends J Ramasamy B Nelissen RGHH Solomon LB Kaptein BL

Aims. The aim of this study was to compare the biomechanical models of two frequently used techniques for reconstructing severe acetabular defects with pelvic discontinuity in revision total hip arthroplasty (THA) – the Trabecular Metal Acetabular Revision System (TMARS) and custom triflange acetabular components (CTACs) – using virtual modelling. Methods. Pre- and postoperative CT scans from ten patients who underwent revision with the TMARS for a Paprosky IIIB acetabular defect with pelvic discontinuity were retrospectively collated. Computer models of a CTAC implant were designed from the preoperative CT scans of these patients. Computer models of the TMARS reconstruction were segmented from postoperative CT scans using a semi-automated method. The amount of bone removed, the implant-bone apposition that was achieved, and the restoration of the centre of rotation of the hip were compared between all the actual TMARS and the virtual CTAC implants. Results. The median amount of bone removed for TMARS reconstructions was significantly greater than for CTAC implants (9.07 cm. 3. (interquartile range (IQR) 5.86 to 21.42) vs 1.16 cm. 3. (IQR 0.42 to 3.53) (p = 0.004). There was no significant difference between the median overall implant-bone apposition between TMARS reconstructions and CTAC implants (54.8 cm. 2. (IQR 28.2 to 82.3) vs 56.6 cm. 2. (IQR 40.6 to 69.7) (p = 0.683). However, there was significantly more implant-bone apposition within the residual acetabulum (45.2 cm. 2. (IQR 28.2 to 72.4) vs 25.5 cm. 2. (IQR 12.8 to 44.1) (p = 0.001) and conversely significantly less apposition with the outer cortex of the pelvis for TMARS implants compared with CTAC reconstructions (0 cm. 2. (IQR 0 to 13.1) vs 23.2 cm. 2. (IQR 16.4 to 30.6) (p = 0.009). The mean centre of rotation of the hip of TMARS reconstructions differed by a mean of 11.1 mm (3 to 28) compared with CTAC implants. Conclusion. In using TMARS, more bone is removed, thus achieving more implant-bone apposition within the residual acetabular bone. In CTAC implants, the amount of bone removed is minimal, while the implant-bone apposition is more evenly distributed between the residual acetabulum and the outer cortex of the pelvis. The differences suggest that these implants used to treat pelvic discontinuity might achieve short- and long-term stability through different biomechanical mechanisms. Cite this article: Bone Joint J 2024;106-B(5 Supple B):74–81


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_14 | Pages 52 - 52
1 Nov 2021
Nakashima Y Ishibashi S Kitamura K Yamate S Motomura G Hamai S Ikemura S Fujii M Yamaguchi R
Full Access

Although periacetabular osteotomies are widely used for the treatment of symptomatic acetabular dysplasia, the surgical outcomes after long term follow-up are still limited. Thus, we assessed hip survival and patient-reported outcomes (PROMs) at 20 years after the transposition osteotomy of acetabulum (TOA). Among 260 hips in 238 patients treated with TOA, 172 hips in 160 patients were evaluated at average 20.8 years, excluding patients who died or lost to follow-up. Kaplan-Meier analysis was used to assess survivorship with an end-point of THA. PROMs were evaluated using the VAS satisfaction, VAS pain, Oxford hip score (OHS), and Forgotten joint score (FJS). The thresholds of favorable outcomes of FJS and OHS were obtained using the receiver-operating characteristic curve with VAS satisfaction ≥ 50 and VAS pain < 20 as anchors. Thirty-three hips (19.2%) underwent THA at average 13.3 years after TOA. Kaplan-Meier analysis revealed hip survival rate at 20 years was 79.7%. Multivariate analysis showed the preoperative Tönnis grade significantly influenced hip survival. Survival rates with Tönnis grade 0, grade 1, and grade 2 were 93.3%, 86.7%, and 54.8% at 20 years, respectively. More than 60% of the patients showed favorable PROMs (VAS satisfaction ≥ 50, VAS pain < 20, OHS ≥ 42, FJS ≥ 51). Advanced Tönnis grade at the latest follow-up and higher BMI were significantly associated with unfavorable OHS, but not with other PROMs. This study demonstrated the durability of TOA for hips with Tönnis grade 0–1 and favorable satisfaction in majority of the patients at 20 years after surgery. Current presence of advanced osteoarthritis is associated with the lower hip function (OHS), but not necessarily associated with subjective pain and satisfaction. Higher BMI also showed a negative impact on postoperative function


Bone & Joint Research
Vol. 10, Issue 9 | Pages 611 - 618
27 Sep 2021
Ali E Birch M Hopper N Rushton N McCaskie AW Brooks RA

Aims. Accumulated evidence indicates that local cell origins may ingrain differences in the phenotypic activity of human osteoblasts. We hypothesized that these differences may also exist in osteoblasts harvested from the same bone type at periarticular sites, including those adjacent to the fixation sites for total joint implant components. Methods. Human osteoblasts were obtained from the acetabulum and femoral neck of seven patients undergoing total hip arthroplasty (THA) and from the femoral and tibial cuts of six patients undergoing total knee arthroplasty (TKA). Osteoblasts were extracted from the usually discarded bone via enzyme digestion, characterized by flow cytometry, and cultured to passage three before measurement of metabolic activity, collagen production, alkaline phosphatase (ALP) expression, and mineralization. Results. Osteoblasts from the acetabulum showed lower proliferation (p = 0.034), cumulative collagen release (p < 0.001), and ALP expression (p = 0.009), and produced less mineral (p = 0.006) than those from the femoral neck. Osteoblasts from the tibia produced significantly less collagen (p = 0.021) and showed lower ALP expression than those from the distal femur. Conclusion. We have demonstrated for the first time an anatomical regional variation in the biological behaviours of osteoblasts on either side of the hip and knee joint. The lower osteoblast proliferation, matrix production, and mineralization from the acetabulum compared to those from the proximal femur may be reflected in differences in bone formation and implant fixation at these sites. Cite this article: Bone Joint Res 2021;10(9):611–618


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_1 | Pages 137 - 137
1 Jan 2016
Fujii Y Fujiwara K Endou H Kagawa Y Ozaki T Abe N Sugita N Mitsuishi M Inoue T Nakashima Y
Full Access

Background. CT-based navigation system in total hip arthroplasty(THA) is widely used to achieve accurate implant placement. The purpose of this study was to evaluate the influence of initial error correction according to the differences in the shape of the acetabulum, and correction accuracy associated with operation approach after localization of registration points at anterior or posterior area of the acetabulum. Methods. We set the anterior pelvic plane(APP) as the reference plane, and defined the coordinates as follows: X-axis for external direction, Y-axis for anterior direction, and Z-axis for proximal direction. APP is defined by the anterior superior iliac spines and anterior border of the pubic symphysis. We made a bone model of bilateral acetabular dysplasia of the hip, after rotational acetabulum osteotomy(RAO) on one side, and performed registration using infrared-reflective markers. At first, we registered the initial error on navigation system, and calculated the accuracy of the error correction based on each shape of the acetabulum as we increased the surface matching points. Based on the actual operation approach, we also examined the accuracy of the error correction when concentrating the matching points in anterior or posterior areas of the acetabulum. Results. For the rotational acetabular osteotomy model, the range of possible initial error correction increased as the surface matching points increased on both X-axis and Y-axis: On the X-axis, the range increased from 6mm to 10mm as the surface matching point increased from 10 to 20; and on the Y-axis, the range increased from 2mm to 10mm as the point increased 10 to 50. The range did not increase on the Z-axis. For the acetabular dysplasia model, the range of possible initial error correction increased on the X-axis(the range increased from 2mm to 8mm as the point increased from 10 to 50); however, no increase was observed for the Y- and Z-axis. Furthermore, concentrating the surface matching points in the posterior area around the acetabulum was more effective for the correction of the initial rotational error. Discussion. Because of the different anatomical shapes of the acetabulum, the error directions that were difficult to correct tended to vary between dysplasia and post-RAO. The error correction of Z-axis was difficult on both shapes of the acetabulum. Thus, the careful initial setting on Z-axis is important to minimize the error. Surface matching point on the posterior part of the acetabulum is more effective in correcting the initial rotational error compared with the anterior part of the acetabulum. It was shown that the difference in the error correction was affected by the localization of the registration points around the acetabulum. We presumed that using surface matching points on posterior area of the acetabulum improves the accuracy of the CT-based navigation system on the anterior approach. When using the system, it is important to understand the tendency that the shape of the acetabulum and the localization of the surface matching points have influence on correction of the initial error


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_20 | Pages 13 - 13
1 Apr 2013
Goudie S Deep K Picard F
Full Access

Introduction. The success of total hip replacement (THR) is closely linked to the positioning of the acetabular component. Malalignment increases rates of dislocation, impingement, acetabular migration, pelvic osteolysis, leg length discrepancy and polyethylene wear. Many surgeons orientate the cup to inherent anatomy of the acetabulum. Detailed understanding of the anatomy and orientation of the acetabulum in arthritic hips is therefore very important. The aim of this study was to describe the anteversion and inclination of the inherent acetabulum in arthritic hips and to identify the number that fall out with the ‘safe zone’ of acetabular position described by Lewinnek et al. (anteversion 15°±10°; inclination 40°±10°). Materials and Methods. A series of 65 hips all with symptomatic osteoarthritis undergoing THR were investigated. Patients with dysplastic hips were excluded. All patients had a navigated THR as part of their normal clinical treatment. A commercially available non image based computer navigation system (Orthopilot BBraun Aesculap, Tuttlingen, Germany) was used. Anterior pelvic plane was registered using the two anterior superior iliac spines and pubic symphysis. Inner size of the empty acetabulum was sized with cup trials and appropriately size trial fixed with a computer tracker was then aligned in the orientation of the natural acetabulum as defined by the acetabular rim ignoring any osteophytes. The inclination and anteversion were calculated by the software. The acetabular inclination in all hips was also measured on pre-operative anteroposterior pelvic digital radiographs. Acetabular inclination was measured using as the angle between a line passing through the superior and inferior rim of the acetabulum and a line parallel to the pelvis as identified by the tear drops, using the method described by Atkinson et al. Results. All patients were Caucasian and had primary osteoarthritis. There were 29 males and 36 females. The average age was 68 years (SD 8). The inclination was 50.4(SD 7.4) and 58.8(SD 5.7) on navigation and radiographs respectively. The anteversion was 9.3(SD 10.3) on navigation. Anteversion for males was significantly lower than females with a mean difference of −5.5° (95% CI −10.5°, −0.5°) with a p value of 0.033. There was no significant difference with respect to inclination. Overall 69% of patients had a combined inclination and anteversion of the native acetabulum that fell outside the “safe zone” of Lewinnek. Conclusions. Inherent acetabular orientation in arthritic hips falls out with the safe zone defined by Lewinnek in 69% of cases. When using the natural acetabular orientation as a guide for positioning implants it should therefore not be assumed this will fall with in the safe zone although the validity of safe zones itself is questionable. Variation between patients must be taken into account. The difference between males and females, particularly in terms of anteversion, should also be considered


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XLIV | Pages 61 - 61
1 Oct 2012
Goudie S Deep K
Full Access

The success of total hip replacement (THR) is closely linked to the positioning of the acetabular component. Malalignment increases rates of dislocation, impingement, acetabular migration, pelvic osteolysis, leg length discrepancy and polyethylene wear. Many surgeons orientate the cup in the same anteversion and inclination as the inherent anatomy of the acetabulum. The transverse acetabular ligament and acetabular rim can be used as a reference points for orientating the cup this way. Low rates of dislocation have been reported using this technique. Detailed understanding of the anatomy and orientation of the acetabulum in arthritic hips is therefore very important. The aim of this study was to describe the anteversion and inclination of the inherent acetabulum in arthritic hips and to identify the number that fall out with the ‘safe zone’ of acetabular position described by Lewinnek et al. (anteversion 15°±10°; inclination 40°±10°). A series of 65 hips, all with symptomatic osteoarthritis undergoing THR were investigated. Patients with developmental dysplastia of hip (DDH) were excluded. All patients had a navigated THR as part of their normal clinical treatment. A posterior approach to the hip was used. A commercially available non image based computer navigation system (Orthopilot BBraun Aesculap, Tuttlingen, Germany) was used. Rigid bodies (using active trackers) were attached to pelvis and femur. Anterior pelvic plane was registered using the two anterior superior iliac spines and pubic symphysis. The femoral head dislocated and removed and the labrum and soft tissue were excised to clear floor and rim of the acetabulum. Inner size of the empty acetabulum was sized with cup trials and appropriately size trial fixed with a computer tracker was then aligned in the orientation of the natural acetabulum as defined by the acetabular rim ignoring any osteophytes. The inclination and anteversion were calculated by the software. Surgery then proceeded with guidance of the computer navigation system. The computer software defines the anatomical values of orientation, to allow comparison with radiographs these were converted to radiological values as described by Murray et al. The acetabular inclination in all hips was also measured on pre-operative anteroposterior pelvic radiographs. This was done using digital radiographs analysed with the PACS system (Kodak, Carestream PACS Client, version 10.0). Acetabular inclination was measured using as the angle between a line passing through the superior and inferior rim of the acetabulum and a line parallel to the pelvis as identified by the tear drops, using the method described by Atkinson et al. All patients were Caucasian and had primary osteoarthritis. There were 29 males and 36 females. The average age was 68 years (SD 8). Mean anteversion was 9.3° (SD 10.3°). Anteversion for males was significantly lower than females with a mean difference of −5.5° (95%CI −10.5°,−0.5°) p = 0.033 but there was no significant difference in the number falling outside the “safe zone”. Mean inclination was 50.4° (SD 7.4°). There was no significant difference between males and females with respect to inclination angle or the number that fell outside the “safe zone”. Overall 69% of patients had a combined inclination and anteversion of the native acetabulum that fell outside the “safe zone” of Lewinnek. Mean acetabular inclination falls out with the ‘safe zone’. This trend has been seen in a recent study of arthritic hips using CT scans which found that the average angle of inclination in both males and females was greater than the upper limit of the safe zone. This study using CT also demonstrated a statistically significant 5.5° difference between males and females in terms of anteversion. This is the same as the figure we have found in our work. Inherent acetabular orientation in arthritic hips falls out with the safe zone defined by Lewinnek in 69% of cases. When using the natural acetabular orientation as a guide for positioning implants it should therefore not be assumed this will fall with in the safe zone although the validity of safe zones itself is questionable. Variation between patients must be taken into account and the difference between males and females, particularly in terms of anteversion, should also be considered


Orthopaedic Proceedings
Vol. 90-B, Issue SUPP_I | Pages 22 - 22
1 Mar 2008
Madan S Fernandes J Taylor J
Full Access

Thirty-four patients were studied through the whole of the Perthes’ disease in Alder Hey Children’s Hospital, Liverpool. The acetabular changes included osteopaenia of the roof, irregularity of its contour, and decrease in the depth. These changes were proportional to the femoral head involvement. The purpose of the study was to know the effect of the morphological changes of the femoral head on the acetabulum and its outcome. Radioisotope scans of the hip were examined in fourteen children with unilateral Perthes’ disease and comparison was made with the contralateral hip. These scans showed increased uptake on the lateral part of the acetabulum and no uptake over the avascular part of the femoral head. Average follow-up was ten years and on an average children were followed up from six years to fifteen years of age. Six readings of the measurements of various dimensions of the acetabulum and the femoral head were done. CT scan also showed irregularity in the acetabulum. Statistical tests lead to the conclusion that the decrease in the depth of the acetabulum was secondary to the femoral head involvement and the extent of its dimensional changes affected the final congruity between the femoral head and the acetabulum. Also the remodelling potential of acetabulum decreases as the child grows older. Therefore containment procedures could be done by femoral osteotomy in younger children and acetabular osteotomy may benefit older children


Orthopaedic Proceedings
Vol. 85-B, Issue SUPP_III | Pages 259 - 259
1 Mar 2003
Grzegorzewski A Synder M Szymczak W Bowen J
Full Access

The purpose of this study is to determine how the lateral shape of the acetabulum changes during Perthes disease and if there is any correlation between the lateral acetabulum shape and final result and type of treatment. The study population consisted of 243 patients with unilateral involvement who had reached skeletal maturity at last follow up. There were 35 (14.4%) female and 208 (85.6%) male patients. The mean age at the onset of symptoms was 7 years and 1 month. AP X-ray films were estimated during fragmentation, reossification and last follow up. Group A consisted of 56 hips, 126 hips were classified as group B and 61 hips as group C according to the Herring classification. For the lateral acetabular shape we proposed a classification: group A – a normal concave acetabular roof, group B – a horizontal flat roof and group C – a roof convexly rounded and up going. All hips were treated by containment methods (bed rest and traction in abduction-78 hips, Petri cast-31 hips, brace-94 hips, varus osteotomy-20 hips, Salter oste-otomy-12 hips and shelf arthroplasty-8 hips). The outcomes of treatment were evaluated according to the Stulberg classification. During fragmentation stage we found 78 (32.1%) hips with normal lateral acetabular shape-type A. Horizontal roof-type B was noted in 136 (56%) hips and in 29 (11.9%) type C was observed. We observed improvement in the shape of lateral acetabulum after treatment. At the last follow up there were 124 (51%) hips with type A, 81 (33.3%) with type B and 38 (15.7%) with type C. Statistical analysis revealed significant correlation between lateral acetabular shape and Stulberg classification. A normal concave acetabular roof at the fragmentation stage leaded mainly to Stulberg group 1and 2 whereas a roof convexly rounded and up going leaded to Stulberg group 3, 4 or 5 (p< 0.0001). Analysis showed no statistical significant correlation between treatment by using bed rest and traction in abduction, Petri cast, braces and development the lateral acetab-ular shape (p=0.09). Only treatment by using surgical methods improved the lateral acetabular shape at the last follow up (p=0.0015). The acetabulum is a mould for remodeling of the deformed femoral head in Perthes disease and the lateral acetabulum plays the most important role. We can expect that normal shape of the acetabulum gives good result at final follow up whereas a roof convexly rounded usually follows to Stulberg group 3, 4 or 5. Only surgical treatment improves the shape of the acetabulum


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_IV | Pages 541 - 541
1 Nov 2011
Poitout D Volpi R Maman P Merger A
Full Access

Purpose of the study: Reconstruction of the acetabulum is becoming increasingly necessary due to the longer life expectancy of patients with a total hip arthroplasty (THA); it can also be needed after trauma or resection of a bone tumour. Material and methods: For 39 cases, we used a bone bank acetabulum with variable size for simple reconstruction of a part of the acetabulum (n=6) or to replace the entire acetabulum (n=19) or even an entire hemi-pelvis (n=14) in patients with more or less extensive bone loss. For 18 cases, resection was necessary to remove a bone tumour (16 chondrosarcomas and two giant-cell tumours), in 19 cases the reconstruction was necessary after multiple operations, and in four others due to traumatic destruction. Results: Allograft integration was successful in nearly all patients (two cases of necrosis required a secondary prosthesis, 12.5%) and in two cases we noted immunological reactions with a serous effusion. There were no local infections. For osteocartilaginous acetabuli (n=7) the integration was quite satisfactory, certain patients have been followed for more than 26 years with no evidence of osteoarthritis. Discussion: Use of a well-established protocol for hypothermia and the absence of secondary sterilisation yields grafts with preserved mechanical properties. The use of cyropreserved osteocartilaginous allografts offers hip for good integration free from degenerative osteoarthritis


The Bone & Joint Journal
Vol. 105-B, Issue 4 | Pages 361 - 364
15 Mar 2023
Vallier HA

Benefits of early stabilization of femoral shaft fractures, in mitigation of pulmonary and other complications, have been recognized over the past decades. Investigation into the appropriate level of resuscitation, and other measures of readiness for definitive fixation, versus a damage control strategy have been ongoing. These principles are now being applied to fractures of the thoracolumbar spine, pelvis, and acetabulum. Systems of trauma care are evolving to encompass attention to expeditious and safe management of not only multiply injured patients with these major fractures, but also definitive care for hip and periprosthetic fractures, which pose a similar burden of patient recumbency until stabilized. Future directions regarding refinement of patient resuscitation, assessment, and treatment are anticipated, as is the potential for data sharing and registries in enhancing trauma system functionality. Cite this article: Bone Joint J 2023;105-B(4):361–364


The Bone & Joint Journal
Vol. 101-B, Issue 4 | Pages 365 - 371
1 Apr 2019
Nam D Salih R Nahhas CR Barrack RL Nunley RM

Aims. Modular dual mobility (DM) prostheses in which a cobalt-chromium liner is inserted into a titanium acetabular shell (vs a monoblock acetabular component) have the advantage of allowing supplementary screw fixation, but the potential for corrosion between the liner and acetabulum has raised concerns. While DM prostheses have shown improved stability in patients deemed ‘high-risk’ for dislocation undergoing total hip arthroplasty (THA), their performance in young, active patients has not been reported. This study’s purpose was to assess clinical outcomes, metal ion levels, and periprosthetic femoral bone mineral density (BMD) in young, active patients receiving a modular DM acetabulum and recently introduced titanium, proximally coated, tapered femoral stem design. Patients and Methods. This was a prospective study of patients between 18 and 65 years of age, with a body mass index (BMI) < 35 kg/m. 2. and University of California at Los Angeles (UCLA) activity score > 6, who received a modular cobalt-chromium acetabular liner, highly crosslinked polyethylene mobile bearing, and cementless titanium femoral stem for their primary THA. Patients with a history of renal disease and metal hardware elsewhere in the body were excluded. A total of 43 patients (30 male, 13 female; mean age 52.6 years (. sd. 6.5)) were enrolled. All patients had a minimum of two years’ clinical follow-up. Patient-reported outcome measures, whole blood metal ion levels (ug/l), and periprosthetic femoral BMD were measured at baseline, as well as at one and two years postoperatively. Power analysis indicated 40 patients necessary to demonstrate a five-fold increase in cobalt levels from baseline (alpha = 0.05, beta = 0.80). A mixed model with repeated measures was used for statistical analysis. Results. Mean Harris Hip Scores improved from 54.1 (. sd. 20.5) to 91.2 (. sd. 10.8) at two years postoperatively (p < 0.001). All patients had radiologically well-fixed components, no patients experienced any instability, and no patients required any further intervention. Mean cobalt levels increased from 0.065 ug/l (. sd. 0.03) preoperatively to 0.30 ug/l (. sd. 0.51) at one year postoperatively (p = 0.01) but decreased at two years postoperatively to 0.16 ug/l (. sd. 0.23; p = 0.2). Four patients (9.3%) had a cobalt level outside the reference range (0.03 ug/l to 0.29 ug/l) at two years postoperatively, with values from 0.32 ug/l to 0.94 ug/l. The mean femoral BMD ratio was maintained in Gruen zones 2 to 7 at both one and two years postoperatively using this stem design. At two years postoperatively, mean BMD in the medial calcar was 101.5% of the baseline value. Conclusion. Use of a modular DM prosthesis and cementless, tapered femoral stem has shown encouraging results in young, active patients undergoing primary THA. Elevation in mean cobalt levels and the presence of four patients outside the reference range at two years postoperatively demonstrates the necessity of continued surveillance in this cohort. Cite this article: Bone Joint J 2019;101-B:365–371


The Bone & Joint Journal
Vol. 100-B, Issue 6 | Pages 725 - 732
1 Jun 2018
Gibon E Barut N Courpied J Hamadouche M

Aims. The purpose of this retrospective study was to evaluate the minimum five-year outcome of revision total hip arthroplasty (THA) using the Kerboull acetabular reinforcement device (KARD) in patients with Paprosky type III acetabular defects and destruction of the inferior margin of the acetabulum. Patients and Methods. We identified 36 patients (37 hips) who underwent revision THA under these circumstances using the KARD, fresh frozen allograft femoral heads, and reconstruction of the inferior margin of the acetabulum. The Merle d’Aubigné system was used for clinical assessment. Serial anteroposterior pelvic radiographs were used to assess migration of the acetabular component. Results. At a mean follow-up of 8.2 years (5 to 19.3), the mean Merle d’Aubigné score increased from 12.5 (5 to 18) preoperatively to 16.5 (10 to 18) (p < 0.0001). The survival rate at ten years was 95.3% (. sd. 4.5; 95% confidence interval (CI) 86.4 to 100) and 76.5% (. sd. 9.9, 95% CI 57.0 to 95.9) using aseptic loosening and radiological loosening as the endpoints, respectively. Conclusion. These results show that the use of the KARD with reconstruction of the inferior margin of the acetabulum in revision THA is associated with acceptable clinical results and survival at mid-term follow-up with, however, a high rate of migration of the acetabular component of 21.6%. Cite this article: Bone Joint J 2018;100-B:725–32


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 9 | Pages 1197 - 1203
1 Sep 2006
Madhu R Kotnis R Al-Mousawi A Barlow N Deo S Worlock P Willett K

This is a retrospective case review of 237 patients with displaced fractures of the acetabulum presenting over a ten-year period, with a minimum follow-up of two years, who were studied to test the hypothesis that the time to surgery was predictive of radiological and functional outcome and varied with the pattern of fracture. Patients were divided into two groups based on the fracture pattern: elementary or associated. The time to surgery was analysed as both a continuous and a categorical variable. The primary outcome measures were the quality of reduction and functional outcome. Logistic regression analysis was used to test our hypothesis, while controlling for potential confounding variables. For elementary fractures, an increase in the time to surgery of one day reduced the odds of an excellent/good functional result by 15% (p = 0.001) and of an anatomical reduction by 18% (p = 0.0001). For associated fractures, the odds of obtaining an excellent/good result were reduced by 19% (p = 0.0001) and an anatomical reduction by 18% (p = 0.0001) per day. When time was measured as a categorical variable, an anatomical reduction was more likely if surgery was performed within 15 days (elementary) and five days (associated). An excellent/good functional outcome was more likely when surgery was performed within 15 days (elementary) and ten days (associated). The time to surgery is a significant predictor of radiological and functional outcome for both elementary and associated displaced fractures of the acetabulum. The organisation of regional trauma services must be capable of satisfying these time-dependent requirements to achieve optimal patient outcomes


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_IV | Pages 598 - 598
1 Oct 2010
Albert LM Boehrensen S
Full Access

Purpose: Coxa magna is well known in Perthes’ disease but a quantitative evaluation of the early, in particular cartilaginous, enlargement of the femoral head and the necessary adaptive changes of the acetabulum (widening and/or growth) does not exist. We would like to present MR-based volumetric data. Methods: We measured the volume of the femoral head and the acetabulum in MRI by means of a software established for the sizing of tumours before therapy and the determination of liver lobe volume prior to transplantation. We evaluated MRI exams in 47 children with Perthes’ disease and 72 normal children from 4 to 9 years and present data of the affected hip in comparison to the unaffected hip and to normal hips. Results:. Femoral head:. On the average the affected head had a volume that was 47% (range 42 – 57%) larger than on the unaffected side and 44 % (range 13 – 59%) larger than in hips of healthy children. Cases with serial exams showed that the volume of the affected head increased in the course of time. Acetabulum:. On the average the acetabular volume was 21% (range 13 to 30%) larger on the affected side than on the unaffected side and 20% (range 10 to 29%) larger than in healthy children. In patients who underwent surgery (pelvic osteotomy, alone or together with intertrochanteric varus osteotomy) the acetabular volume was 24% larger (range 9 – 33%) on the affected side than on the unaffected side. In patients without surgery the acetabular volume was 16% larger (range 10 to 33%) on the affected side. Conclusions:. We found that Perthes’ disease is associated with an average increase of femoral head volume of 47% in comparison to the unaffected side and of 44% in comparison to healthy children. There was an average increase of the acetabular volume of 21% in comparison to the unaffected side and of 20% in comparison to healthy children. These data may allow a better understanding of the disease and a reappraisal of current forms of treatment. Significance: Given a chronic disproportion between the size of the femoral head and the acetabulum therapy should aim at:. Retardation of the (cartilaginous) enlargement of the femoral head. Promotion of widening or growth of the acetabulum. We believe that current conservative modes of treatment are effective through rationale A and B. Operative modalities, in particular pelvic osteotomies and/or intertrochanteric varus osteotomy, seem to be mainly effective through rationale B. By reorientation of the acetabulum and/or the proximal femur they should favour a better distribution of forces through the hip joint allowing for a gradual widening of the acetabulum. In addition, the operative trauma in the vicinity of the triradiate cartilage may have a stimulating effect on acetabular growth


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_19 | Pages 15 - 15
1 Apr 2013
Nalwad H Goudie S Deep K
Full Access

Introduction. Success of total hip replacement (THR) is closely linked to positioning of the acetabular component. Malalignment increases complication rates. Our aim was to describe the anteversion and inclination of the inherent acetabulum in arthritic hips and identify the number that fall out with the ‘safe zone’ of acetabular position described by Lewinnek et al. (anteversion 15±10 degrees; inclination 40±10 degrees). Materials/Methods. A series of 65 hips undergoing non-image based computer navigated THR for Osteoarthritis were investigated. Anteversion and inclination was measured with the help of cup trials fixed with computer trackers aligned in orientation of the natural acetabulum. The acetabular inclination in all hips was measured on pre-operative digital radiographs. Results. There were 29 males and 36 females with average age of 68 years. Anteversion of males was significantly lower than females with a mean difference of −5.5 degrees (95% CI-10.5–0.5 degrees) with p value of 0.033. There was no significant difference with respect to inclination. Overall 69 % of patients had a combined inclination and anteversion that fell outside the ‘safe zone’. Conclusion. Mean acetabular inclination falls outwith the ‘safe zone’ but mean anteversion falls within. The inherent acetabular anatomy of arthritic hips varies widely. Females have significantly more anteversion. Care should be taken when using inherent anatomy of acetabulum as a guide when doing a THR


The Bone & Joint Journal
Vol. 106-B, Issue 2 | Pages 128 - 135
1 Feb 2024
Jenkinson MRJ Cheung TCC Witt J Hutt JRB

Aims. The aim of this study is to evaluate whether acetabular retroversion (AR) represents a structural anatomical abnormality of the pelvis or is a functional phenomenon of pelvic positioning in the sagittal plane, and to what extent the changes that result from patient-specific functional position affect the extent of AR. Methods. A comparative radiological study of 19 patients (38 hips) with AR were compared with a control group of 30 asymptomatic patients (60 hips). CT scans were corrected for rotation in the axial and coronal planes, and the sagittal plane was then aligned to the anterior pelvic plane. External rotation of the hemipelvis was assessed using the superior iliac wing and inferior iliac wing angles as well as quadrilateral plate angles, and correlated with cranial and central acetabular version. Sagittal anatomical parameters were also measured and correlated to version measurements. In 12 AR patients (24 hips), the axial measurements were repeated after matching sagittal pelvic rotation with standing and supine anteroposterior radiographs. Results. Acetabular version was significantly lower and measurements of external rotation of the hemipelvis were significantly increased in the AR group compared to the control group. The AR group also had increased evidence of anterior projection of the iliac wing in the sagittal plane. The acetabular orientation angles were more retroverted in the supine compared to standing position, and the change in acetabular version correlated with the change in sagittal pelvic tilt. An anterior pelvic tilt of 1° correlated with 1.02° of increased cranial retroversion and 0.76° of increased central retroversion. Conclusion. This study has demonstrated that patients with symptomatic AR have both an externally rotated hemipelvis and increased anterior projection of the iliac wing compared to a control group of asymptomatic patients. Functional sagittal pelvic positioning was also found to affect AR in symptomatic patients: the acetabulum was more retroverted in the supine position compared to standing position. Changes in acetabular version correlate with the change in sagittal pelvic tilt. These findings should be taken into account by surgeons when planning acetabular correction for AR with periacetabular osteotomy. Cite this article: Bone Joint J 2024;106-B(2):128–135


The Bone & Joint Journal
Vol. 104-B, Issue 7 | Pages 775 - 780
1 Jul 2022
Kołodziejczyk K Czubak-Wrzosek M Kwiatkowska M Czubak J

Aims. Developmental dysplasia of the hip (DDH) describes a pathological relationship between the femoral head and acetabulum. Periacetabular osteotomy (PAO) may be used to treat this condition. The aim of this study was to evaluate the results of PAO in adolescents and adults with persistent DDH. Methods. Patients were divided into four groups: A, adolescents who had not undergone surgery for DDH in childhood (25 hips); B, adolescents who had undergone surgery for DDH in childhood (20 hips); C, adults with DDH who had not undergone previous surgery (80 hips); and D, a control group of patients with healthy hips (70 hips). The radiological evaluation of digital anteroposterior views of hips included the Wiberg angle (centre-edge angle (CEA)), femoral head cover (FHC), medialization, distalization, and the ilioischial angle. Clinical assessment involved the Harris Hip Score (HHS) and gluteal muscle performance assessment. Results. Significant improvements in radiological parameters were achieved in all measurements in all groups (p < 0.05). The greatest improvement was in CEA (mean of 19° (17.2° to 22.3°) in Group B), medialization (mean of 3 mm (0.9 to 5.2) in Group C), distalization (mean of 6 mm (3.5 to 8.2) in Group B), FHC (mean of 17% (12.7% to 21.2%) in Group B), and ilioischial angle (mean of 5° (2.3° to 8.1°) in Group B). There were significant improvements in the mean HHS and gluteal muscle performance scores postoperatively in all three groups. Conclusion. The greatest correction of radiological parameters and clinical outcomes was found in patients who had undergone hip surgery in childhood. Although the surgical treatment of DDH in childhood makes subsequent hip surgery more difficult due to scarring, adhesions, and altered anatomy, it requires less correction of the deformity and has a beneficial effect on the outcome of PAO in adolescence and early adulthood. Cite this article: Bone Joint J 2022;104-B(7):775–780


The Journal of Bone & Joint Surgery British Volume
Vol. 81-B, Issue 2 | Pages 281 - 288
1 Mar 1999
Reynolds D Lucas J Klaue K

We describe a little-known variety of hip dysplasia, termed ‘acetabular retroversion’, in which the alignment of the mouth of the acetabulum does not face the normal anterolateral direction, but inclines more posterolaterally. The condition may be part of a complex dysplasia or a single entity. Other than its retroversion, the acetabulum is sited normally on the side wall of the pelvis, and its articular surface is of normal extent and configuration. The retroverted orientation may give rise to problems of impingement between the femoral neck and anterior acetabular edge. We define the clinical and radiological parameters and discuss pathological changes which may occur in the untreated condition. A technique of management is proposed


The Bone & Joint Journal
Vol. 105-B, Issue 7 | Pages 760 - 767
1 Jul 2023
Tanaka S Fujii M Kawano S Ueno M Sonohata M Kitajima M Mawatari D Mawatari M

Aims. The aims of this study were to validate the Forgotten Joint Score-12 (FJS-12) in the postoperative evaluation of periacetabular osteotomy (PAO), identify factors associated with joint awareness after PAO, and determine the FJS-12 threshold for patient-acceptable symptom state (PASS). Methods. Data from 686 patients (882 hips) with hip dysplasia who underwent transposition osteotomy of the acetabulum, a type of PAO, between 1998 and 2019 were reviewed. After screening the study included 442 patients (582 hips; response rate, 78%). Patients who completed a study questionnaire consisting of the visual analogue scale (VAS) for pain and satisfaction, FJS-12, and Hip disability and Osteoarthritis Outcome Score (HOOS) were included. The ceiling effects, internal consistency, convergent validity, and PASS thresholds of FJS-12 were investigated. Results. The median follow-up was 12 years (interquartile range 7 to 16). The ceiling effect of FJS-12 was 7.2%, the lowest of all the measures examined. FJS-12 correlated with all HOOS subscales (ρ = 0.72 to 0.77, p < 0.001) and pain and satisfaction-VAS (ρ = -0.63 and 0.56, p < 0.001), suggesting good convergent validity. Cronbach’s α was 0.95 for the FJS-12, which indicated excellent internal consistency. The median FJS-12 score for preoperative Tönnis grade 0 hips (60 points) was higher than that for grade 1 (51 points) or 2 (46 points). When PASS was defined as pain-VAS < 21 and satisfaction-VAS ≥ 77, the FJS-12 threshold that maximized the sensitivity and specificity for detecting PASS was 50 points (area under the curve (AUC) = 0.85). Conclusion. Our results suggest that FJS-12 is a valid and reliable assessment tool for patients undergoing PAO, and the threshold of 50 points may be useful to determine patient satisfaction following PAO in clinical settings. Further investigation of the factors influencing postoperative joint awareness may enable improved prediction of treatment efficacy and informed decision-making regarding the indication of PAO. Cite this article: Bone Joint J 2023;105-B(7):760–767


Bone & Joint Open
Vol. 4, Issue 10 | Pages 782 - 790
18 Oct 2023
Hamilton DF Gaston P Macpherson GJ Simpson P Clement ND

Aims. The primary aim of this study is to assess the survival of the uncemented hydroxyapatite (HA) coated Trident II acetabular component as part of a hybrid total hip arthroplasty (THA) using a cemented Exeter stem. The secondary aims are to assess the complications, joint-specific function, health-related quality of life, and radiological signs of loosening of the acetabular component. Methods. A single-centre, prospective cohort study of 125 implants will be undertaken. Patients undergoing hybrid THA at the study centre will be recruited. Inclusion criteria are patients suitable for the use of the uncemented acetabular component, aged 18 to 75 years, willing and able to comply with the study protocol, and provide informed consent. Exclusion criteria includes patients not meeting study inclusion criteria, inadequate bone stock to support fixation of the prosthesis, a BMI > 40 kg/m. 2. , or THA performed for pain relief in those with severely restricted mobility. Results. Implant survival, complications, functional outcomes and radiological assessment up to ten years following index THA (one, two, five, seven, and ten years) will be performed. Functional assessment will include the Oxford Hip Score, Forgotten Joint Score, 12-Item Short Form Health Survey, EuroQol five-dimension health questionnaire, and pain and patient satisfaction. Radiological assessment with assess for acetabula lucent lines, lysis, and loosening according to DeLee and Charnley zones. Conclusion. This study is part of a stepwise introduction of a new device to orthopaedic practice, and careful monitoring of implants should be carried out as part of the Beyond Compliance principles. The results of this study will provide functional, radiological, and survival data to either support the ongoing use of the HA acetabulum or highlight potential limitations of this new implant before wide adoption. Cite this article: Bone Jt Open 2023;4(10):782–790


Orthopaedic Proceedings
Vol. 86-B, Issue SUPP_I | Pages 82 - 82
1 Jan 2004
Pradhan N Gambhir AK Leonard D Porter ML
Full Access

A secure bone/cement interface at the bone cement junction is an important requirement for the long-term success in the cemented hip arthroplasty. Cementing techniques have evolved and now involve pressurisation of the acetabulum and femur. It can be difficult to get a complete rim seal and hence adequate pressurisation due to the unique anatomy of the acetabulum and the contyloid notch. Several acetabular pressurisers are commercially available. We have developed an instrument for controlled and reproducible cement pressurisation in the acetabulum before socket insertion. It is a T-bar incorporating a central plunger, which protrudes from an outer sleeve when force is applied. The protrusion of the central plunger and hence the amount of force applied can be limited by a stop-sleeve. A laboratory saw bone model was designed to assess this system and compare it with two existing pressurisers. A polypropylene model of the acetabulum was used. Included in the model were two 1.3mm diameter capillary outlets, one at its pole and one at a point close to its rim opposite the cotyloid notch. Water was free to flow through the capillaries at a pressure of 13.5” WG to represent blood flow. 5 test per pressuriser were performed. CMW 1 Gentamicin bone cement was mixed as per manufacturers instruction in a Vacuum Mix system. The cement was then pressurised using one of three systems; the Depuy T handle pressuriser, the Exeter pressuriser and our new instrument. The cement mantle produced with the Depuy T-handle and the Exeter pressuriser was thicker at the pole than the rim and the cement intrusion was not consistent nor reproducible. The new pressurizer produced a cement mantle equal at the pole and the rim to within 1mm. A reproducible cement mantle compatible to the shape of the socket and with cement intrusion of 5mm (+/− 1mm) could be achieved. We recommend the use of this pressuriser


Orthopaedic Proceedings
Vol. 84-B, Issue SUPP_III | Pages 283 - 283
1 Nov 2002
Love B
Full Access

Various assumptions must be made during total hip replacement when placing the acetabular component within the reamed acetabulum with regards to its orientation. Various methods have been described for different acetabular components, some relying on knowledge of the existing anatomy and some relying on the use of jigs to align the component. Many of these assumptions are based on opinion rather than science and the current study was designed to define the position of the acetabulum in relation to a fixed position of the pelvis. A neutral position of the pelvis must be defined and this is represented by having a line from the anterior superior iliac spine to the pubis fixed in the coronal plane and taking measurements of the perpendicular axis of the pelvis taken from this. A variety of measurements were made using measurement techniques and the conclusion was reached that the average angle for operative inclination is 43 degrees ± 5 degrees and the average angle for operative anteversion is 29 degrees ± 8 degrees. These figures should give a preliminary guide to the correct placement of the acetabular socket in total hip replacement although other factors may need to be taken into account


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 5 | Pages 670 - 672
1 May 2006
Darmanis S Bircher M

We describe two patients aged 16 and 25 years with osteogenesis imperfecta who sustained displaced fractures of the acetabulum following minor trauma. The femoral heads were deformed by impact against the acetabular margin and both cases underwent surgical reconstruction. The quality of the bone and soft tissues made the operations challenging. There were potential complications specific to osteogenesis imperfecta, including bleeding, the creation of secondary fracture lines and shredding of the soft-tissue. The cases provide useful guidelines for addressing these difficulties


Bone & Joint Open
Vol. 3, Issue 2 | Pages 158 - 164
17 Feb 2022
Buddhdev P Vallim F Slattery D Balakumar J

Aims. Slipped upper femoral epiphysis (SUFE) has well documented biochemical and mechanical risk factors. Femoral and acetabular morphologies seem to be equally important. Acetabular retroversion has a low prevalence in asymptomatic adults. Hips with dysplasia, osteoarthritis, and Perthes’ disease, however, have higher rates, ranging from 18% to 48%. The aim of our study was to assess the prevalence of acetabular retroversion in patients presenting with SUFE using both validated radiological signs and tomographical measurements. Methods. A retrospective review of all SUFE surgical cases presenting to the Royal Children’s Hospital, Melbourne, Australia, from 2012 to 2019 were evaluated. Preoperative plain radiographs were assessed for slip angle, validated radiological signs of retroversion, and standardized postoperative CT scans were used to assess cranial and mid-acetabular version. Results. In all, 116 SUFEs presented in 107 patients who underwent surgical intervention; 47 (52%) were male, with a mean age of 12.7 years (7.5 to 16.6). Complete radiological data was available for 91 patients (99 hips) with adequate axial CT imaging of both hips. Overall, 82 patients (82%) underwent pinning in situ (PIS), with subcapital realignment surgery (SRS) performed in 17 patients (18%) (slip angles > 75°). Contralateral prophylactic PIS was performed in 72 patients (87%). On the slip side, 62 patients (68%) had one or more radiological sign of retroversion. Tomographical acetabular retroversion was more pronounced cranially than caudally of the acetabulum on both the affected side and the contralateral side (p < 0.001) as expected in the normal population. Increasing severity of the slip was found to be directly proportional to the degree of reduction in cranial and central acetabular version (p < 0.05) in the SUFE hips. Conclusion. Acetabular retroversion is more prevalent in patients with SUFE than previously reported, and have been shown be correlated to the severity of the slip presentation. The presence of radiological signs of acetabular retroversion could be used to justify prophylactic contralateral pinning. Cite this article: Bone Jt Open 2022;3(2):158–164


The Bone & Joint Journal
Vol. 106-B, Issue 4 | Pages 336 - 343
1 Apr 2024
Haertlé M Becker N Windhagen H Ahmad SS

Aims. Periacetabular osteotomy (PAO) is widely recognized as a demanding surgical procedure for acetabular reorientation. Reports about the learning curve have primarily focused on complication rates during the initial learning phase. Therefore, our aim was to assess the PAO learning curve from an analytical perspective by determining the number of PAOs required for the duration of surgery to plateau and the accuracy to improve. Methods. The study included 118 consecutive PAOs in 106 patients. Of these, 28 were male (23.7%) and 90 were female (76.3%). The primary endpoint was surgical time. Secondary outcome measures included radiological parameters. Cumulative summation analysis was used to determine changes in surgical duration. A multivariate linear regression model was used to identify independent factors influencing surgical time. Results. The learning curve in this series was 26 PAOs in a period of six months. After 26 PAO procedures, a significant drop in surgical time was observed and a plateau was also achieved. The mean duration of surgery during the learning curve was 103.8 minutes (SD 33.2), and 69.7 minutes (SD 18.6) thereafter (p < 0.001). Radiological correction of acetabular retroversion showed a significant improvement after having performed a total of 93 PAOs, including anteverting PAOs on 35 hips with a retroverted acetabular morphology (p = 0.005). Several factors were identified as independent variables influencing duration of surgery, including patient weight (β = 0.5 (95% confidence interval (CI) 0.2 to 0.7); p < 0.001), learning curve procedure phase of 26 procedures (β = 34.0 (95% CI 24.3 to 43.8); p < 0.001), and the degree of lateral correction expressed as the change in the lateral centre-edge angle (β = 0.7 (95% CI 0.001 to 1.3); p = 0.048). Conclusion. The learning curve for PAO surgery requires extensive surgical training at a high-volume centre, with a minimum of 50 PAOs per surgeon per year. This study defined a cut-off value of 26 PAO procedures, after which a significant drop in surgical duration occurred. Furthermore, it was observed that a retroverted morphology of the acetabulum required a greater number of procedures to acquire proficiency in consistently eliminating the crossover sign. These findings are relevant for fellows and fellowship programme directors in establishing the extent of training required to impart competence in PAO. Cite this article: Bone Joint J 2024;106-B(4):336–343


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_III | Pages 248 - 249
1 Jul 2011
Lubocsky O Hardisty MR Wright D Kreder HJ Whyne C
Full Access

Purpose: The distribution of weight bearing area within the acetabulum is of importance in addressing trauma to the acetabulum, hip joint deformities and causes of osteoarthritis. According to Wolf’s law, bone density can indicate loading patterns experienced. The objective of this study was to characterize distributions of acetabular bone density patterns by regions in the normal population. Method: CT scans of 22 subjects, mean age 70.6 with no evidence to hip joint pathologies were analysed. Bone density distribution maps were generated within AmiraDEV4.1 image analysis software using custom written plugins (Visage Imaging, Carlsbad, USA). Acetabular cup surfaces were semi-automatically segmented from the reconstructed CT volumes with an atlas-based approach. The acetabular cups were expanded 2.5 mm into the acetabular bone, and surface bone densities were calculated as the average bone density within ±2.5mm. The distribution maps were analysed using zones to spatially classify areas of high and low bone density in a healthy population. The acetabular cups were aligned using the acetabular rim plane that was landmarked, and by rotating the cups, such that a 900 abduction angle and a 00 anteversion angle were achieved. The grid used was divided to quadrants, and subdivided into radial thirds of the average rim radius. The correspondence of left and right density maps was investigated by comparing the average bone density in corresponding zones and across the population. Results: High bone densities were found around the roof of the acetabulum aligning with the femoral mechanical axis during standing. The highest average bone density were found to be the superior and posterior walls of the acetabulum, corresponding to regions 8, 9, and 12 compared to other regions of the acetabuli (P< 0.01). A strong correlation was found between left and right sides within subjects (R=0.91, P< 0.05); and weaker correlation was also found for overall average bone density, (R=0.77, P< 0.05). Conclusion: The location of the zones with the highest average bone density agrees with cadaveral studies of the maximum contact stress in the acetabulum (zones 9 and 12). [1,2]. It may explain why trauma to these areas carries a higher risk for early arthritic changes


Orthopaedic Proceedings
Vol. 91-B, Issue SUPP_I | Pages 1 - 1
1 Mar 2009
Botan N Fourie B Scott S Shaw N
Full Access

The JRI cemented total hip replacement consisted of an acetabulum with a gamma irradiated UHMW polyethylene cup encased in a titanium metal shell, a 32 mm titanium head, and forged titanium alloy stem. Revision of this implant for failure, in particular that of the acetabulum, and the lack of published survivorship prompted a retrospective review of the local series. Data was compiled from theatre log books, patient records and X-rays. During the period 1989–1997 a single surgeon performed 304 total hip replacements using this JRI prosthesis through an anterior lateral approach. The average age was 70 (48–96), with 186 (61%) female and 85% performed for osteoarthritis. Complete data was available in 236 cases to allow further analysis. The average follow up was 9.3 (1–17) years. During this period 37 hips had to be revised: 28 for a loose acetabulum, both components were loose in 5, and 3 had revision for infection. The mean time to revision was 7.4 (1–17) years. This data provides a revision rate of at least 16% at ten years. This data does not take potential earlier radiographic failure nor patient function into account. This prosthesis therefore fails to comply with modern benchmarks for survivorship of implants. Furthermore this study highlights the importance of ongoing review of patients who have undergone joint replacement, in particular those with implants that have problems with design, as has been demonstrated in other metal backed components


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 12 | Pages 1613 - 1617
1 Dec 2006
Karunakar MA Sen A Bosse MJ Sims SH Goulet JA Kellam JF

Our study was designed to compare the effect of indometacin with that of a placebo in reducing the incidence of heterotopic ossification in a prospective, randomised trial. A total of 121 patients with displaced fractures of the acetabulum treated by operation through a Kocher-Langenbeck approach was randomised to receive either indometacin (75 mg) sustained release, or a placebo once daily for six weeks. The extent of heterotopic ossification was evaluated on plain radiographs three months after operation. Significant ossification of Brooker grade III to IV occurred in nine of 59 patients (15.2%) in the indometacin group and 12 of 62 (19.4%) receiving the placebo. We were unable to demonstrate a statistically significant reduction in the incidence of severe heterotopic ossification with the use of indometacin when compared with a placebo (p = 0.722). Based on these results we cannot recommend the routine use of indometacin for prophylaxis against heterotopic ossification after isolated fractures of the acetabulum


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXV | Pages 5 - 5
1 Jun 2012
Asal MK
Full Access

Fracture of the acetabulum can lead to degenerative arthritis of the hip, avascular necrosis of the femoral head, or both. Total hip arthroplasty is a common form of surgical treatment when significant joint changes and pain are present. Ten patients with fracture acetabulum were treated in this study using metal on metal total hip arthoplasty. The initial fracture was posterior wall fracture in one patient, posterior column fracture in one patient, transverse fracture in 2 patients, fracture dislocation in 3 patients and fracture posterior wall and column in 3 patients. The indications of arthroplasty were secondry osteoarthritis after internal fixation or after conservative management or collapse of the femoral head. Arthroplasty was done after an average period of 1.8 years (range from 1 to 4 years). After a follow up period ranged from 3 to 7 years with a mean of 4.6 years, the Harris hip score was improved from a mean of 51 (range 20 to 65) to a mean of 92.5 (range 90 to 95). Infection occurred in one case and two stages revision was done. Another case developed loosening of the acetabular component and was revised using cementless cup fixed with screws and bone graft. Metal on metal THR after acetabular fracture are relatively uncomplicated and lead to a good outcome despite the difficulties faced during the procedure


Bone & Joint Research
Vol. 10, Issue 9 | Pages 594 - 601
24 Sep 2021
Karunaseelan KJ Dandridge O Muirhead-Allwood SK van Arkel RJ Jeffers JRT

Aims. In the native hip, the hip capsular ligaments tighten at the limits of range of hip motion and may provide a passive stabilizing force to protect the hip against edge loading. In this study we quantified the stabilizing force vectors generated by capsular ligaments at extreme range of motion (ROM), and examined their ability to prevent edge loading. Methods. Torque-rotation curves were obtained from nine cadaveric hips to define the rotational restraint contributions of the capsular ligaments in 36 positions. A ligament model was developed to determine the line-of-action and effective moment arms of the medial/lateral iliofemoral, ischiofemoral, and pubofemoral ligaments in all positions. The functioning ligament forces and stiffness were determined at 5 Nm rotational restraint. In each position, the contribution of engaged capsular ligaments to the joint reaction force was used to evaluate the net force vector generated by the capsule. Results. The medial and lateral arms of the iliofemoral ligament generated the highest inbound force vector in positions combining extension and adduction providing anterior stability. The ischiofemoral ligament generated the highest inbound force in flexion with adduction and internal rotation (FADIR), reducing the risk of posterior dislocation. In this position the hip joint reaction force moved 0.8° inbound per Nm of internal capsular restraint, preventing edge loading. Conclusion. The capsular ligaments contribute to keep the joint force vector inbound from the edge of the acetabulum at extreme ROM. Preservation and appropriate tensioning of these structures following any type of hip surgery may be crucial to minimizing complications related to joint instability. Cite this article: Bone Joint Res 2021;10(9):594–601


Bone & Joint Open
Vol. 4, Issue 10 | Pages 735 - 741
2 Oct 2023
Galloway AM Pini S Holton C Perry DC Redmond A Siddle HJ Richards S

Aims. Perthes’ disease is an idiopathic avascular necrosis of the developing femoral head, often causing deformity that impairs physical function. Current treatments aim to optimize the joint reaction force across the hip by enhancing congruency between the acetabulum and femoral head. Despite a century of research, there is no consensus regarding the optimal treatment. The aim of this study was to describe the experiences of children, their families, and clinicians when considering the treatment of Perthes’ disease. Methods. A qualitative study gathered information from children and their families affected by Perthes’ disease, along with treating clinicians. Interviews followed a coding framework, with the interview schedule informed by behavioural theory and patient and public involvement. Transcripts were analyzed using the framework method. Results. A total of 24 interviews took place, with 12 child/family dyads and 12 clinicians from UK NHS centres. Interviews identified widespread variation of routine care. Children/their families recounted positive experiences when included in the decision-making process for treatment. There is a strong desire from clinicians and children/families for consistent guidance from everyone involved in care, which should be based on clinical consensus. Conclusion. This is the first study to describe how children/families and clinicians experienced receiving or providing treatment in Perthes’ disease. The results indicate the need for robust evidence to support treatment decisions. Children and families valued feeling involved in the clinical decision-making process. Clinicians acknowledged the central importance of providing patient-centred care, particularly in the absence of robust evidence to guide the optimal treatment decisions. This study will inform a future Delphi project to develop clinical consensus guidelines for the treatment of Perthes’ disease. Cite this article: Bone Jt Open 2023;4(10):735–741


The Bone & Joint Journal
Vol. 104-B, Issue 7 | Pages 781 - 785
1 Jul 2022
Ferraro SL Williams DN Millis MB

Aims. The aim of this study was to understand the experience of mature patients who undergo a periacetabular osteotomy (PAO), a major hip-preserving surgical procedure that treats symptomatic hip dysplasia by realigning the acetabulum. Our aim was to improve our understanding of how the operation affected the lives of patients and their families, with a long-term goal of improving their experience. Methods. We used a phenomenological approach with in-depth, semi-structured interviews to investigate the experience of seven female patients, aged between 25 and 40 years, who underwent a PAO. A modified homogeneity sampling approach coupled with criterion sampling was used. Inclusion criteria involved having at least one child at home and being in a committed relationship with a spouse or partner. Results. Analysis of interview transcripts revealed five major themes: feelings of frustration before having a treatment plan; fear of the operation; the importance of understanding the procedure in order to feel in control of their care; feelings of helplessness, dependence, and depression during recovery; and the need for support during recovery. Conclusion. Our findings suggest that both the physical and psychosocial burdens of undergoing a PAO are great, with a major impact on the patient and their family. Many important issues lie outside the scope of what healthcare teams currently address. Cite this article: Bone Joint J 2022;104-B(7):781–785


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 1 | Pages 2 - 9
1 Jan 2005
Giannoudis PV Grotz MRW Papakostidis C Dinopoulos H

Over the past 40 years, the management of displaced fractures of the acetabulum has changed from conservative to operative. We have undertaken a meta-analysis to evaluate the classification, the incidence of complications and the functional outcome of patients who had undergone operative treatment of such injuries. We analysed a total of 3670 fractures. The most common long-term complication was osteoarthritis which occurred in approximately 20% of the patients. Other late complications, including heterotopic ossification and avascular necrosis of the femoral head, were present in less than 10%. However, only 8% of patients who were treated surgically needed a further operation, usually a hip arthroplasty, and between 75% and 80% of patients gained an excellent or good result at a mean of five years after injury. Factors influencing the functional outcome included the type of fracture and/or dislocation, damage to the femoral head, associated injuries and co-morbidity which can be considered to be non-controllable, and the timing of the operation, the surgical approach, the quality of reduction and local complications which are all controllable. The treatment of these injuries is challenging. Tertiary referrals need to be undertaken as early as possible, since the timing of surgery is of the utmost importance. It is important, at operation, to obtain the most accurate reduction of the fracture which is possible, with a minimal surgical approach, as both are related to improved outcome


The Journal of Bone & Joint Surgery British Volume
Vol. 78-B, Issue 6 | Pages 871 - 877
1 Nov 1996
Shindo H Igarashi H Taneda H Azuma H

We have divided Severin group-V severely dysplastic hips with a false into three subtypes, based on the height and shape of the socket. We performed rotational acetabular osteotomy (RAO) in 19 hips in 17 young adults with a type-1 ‘low’ false acetabulum which had direct contact with the true acetabulum. This is a periacetabular osteotomy which gives acetabular coverage with articular cartilage and produces a nearly normal position of the head. Concomitant osteotomies of the proximal femur were carried out in 11 hips. We reviewed the patients clinically and radiologically at a mean of ten years (6 to 18) after operation. Of the 19 hips, 15 showed very good or good results. This operation is indicated in young adults with a dysplastic hip and a type-1 low false acetabulum. Subclassification of Severin group V is a convenient way of defining those patients who would benefit from the procedure


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 4 | Pages 503 - 509
1 Apr 2007
Giannoudis PV Tzioupis C Moed BR

Our aim was to evaluate the efficacy of a two-level reconstruction technique using subchondral miniscrews for the stabilisation of comminuted posterior-wall marginal acetabular fragments before applying lag screws and a buttress plate to the main overlying posterior fragment. Between 1995 and 2003, 29 consecutive patients with acute comminuted displaced posterior-wall fractures of the acetabulum were treated operatively using this technique. The quality of reduction measured from three standard plain radiographs was graded as anatomical in all 29 hips. The clinical outcome at a mean follow-up of 35 months (24 to 90) was considered to be excellent in five patients (17%), very good in 16 (55%), good in six (21%) and poor in two (7%). The use of the two-level reconstruction technique appears to provide stable fixation and is associated with favourable results in terms of the incidence of post-traumatic osteoarthritis and the clinical outcome. However, poor results may occur in patients over the age of 55 years


Orthopaedic Proceedings
Vol. 87-B, Issue SUPP_III | Pages 397 - 397
1 Sep 2005
Madan SS Boschetti D Ganz R
Full Access

The effects of NF-I on the hip have been underreported in literature. The bony changes in the hip can be mild to severe and are often present, but not diagnosed. Dislocation of the hip has been described but protrusio acetabulum is underdiagnosed and has only been reported from one institute. This is the first case where an open biopsy has been taken from the hip joint by surgical dislocation with preservation of the blood supply to the femoral head. Gross and microscopic pathology in the neurofibromatosis of the hip has been described for the first time in our report. A 16-year-old girl presented with history of pain, limp and stiffness in the right hip for several years. Radiographs, CT scan showed severe protrusio acetabulum. Histological analysis from the tissue taken from the hip was a neurofibroma. There was very minimal hyaline cartilage in the acetabulum at operation. Therefore the floor of the acetabulum was grafted with the autologous cancellous bone chips obtained from her greater trochanter. The aim of this was to lateralize the hip center to a normal position. At six months follow up she was doing well. Her range of movements had increased by 20%


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_31 | Pages 46 - 46
1 Aug 2013
McConaghie F Payne A Kinninmonth A
Full Access

Previous work has demonstrated vulnerability of the femoral nerve to damage by anterior acetabular retractors during THA. The aim of this study was to quantify the proximity of the femoral nerve to the anterior acetabulum, on cadaveric material and MRI studies. A standard posterior approach to the hip was carried out in 6 fresh frozen cadaveric hemipelves. Following dislocation and removal of the femoral head, measurements were taken from the anterior acetabular lip to the posterior aspect of the femoral nerve as it passed over this point. 14 MRI studies of the hip were obtained from the local PACS database (7 male, 7 female; mean age 58 (range 32–80)). T1 weighted axial scans were reviewed. Measurements were obtained from the anterior acetabular lip to the posterior surface of the femoral nerve and artery, and the cross-sectional area of iliopsoas was calculated. There was no significant difference between the mean distances to the femoral nerve in the cadaveric (24 mm) and MRI groups (25.3mm) (p=0.7). On MRI images, the distance between the acetabular wall and both the femoral artery (p=0.003) and femoral nerve (p=0.007) was significantly larger in men. The femoral artery is strikingly close to the acetabulum in females, passing a mean distance of 14.8 mm, whereas in males this was 23.9 mm. The mean femoral nerve distance was 28.7 mm in males and 21.9 mm in females. The cross-sectional area of iliopsoas was significantly smaller in women (5.97 cm. 2. compared to 11.37 cm. 2. , p<0.001). Both the femoral artery and nerve run in close proximity to the anterior acetabular lip. Care should be taken when placing instruments in this area to avoid neurovascular injury. The increased incidence of femoral nerve damage in women following THA may be due to the significantly smaller bulk of iliopsoas


Orthopaedic Proceedings
Vol. 86-B, Issue SUPP_I | Pages 37 - 37
1 Jan 2004
Beaule P Matta J
Full Access

Purpose: The surgical approach is an essential element for precise reduction and rigid fixation of fractures of the acetabulum. In cases where the anterior column is mainly involved and total hip arthroplasty (THA) is indicated, classical approaches do not allow double assess to the anterior column necessary for reduction and fixation and to the femoral canal for insertion of the prosthesis. Combining Heuter’s anterior approach and Letournel’s ilio-femoral approach provides access to the anterior column and to the often associated posterior hemi-transverse fracture, while allowing insertion of the total hip prosthesis. Material and method: This combined approach was used for ten among 60 THA performed for fracture of the acetabulum. Seven were primary procedures and three were differed reconstruction procedures. Mean patient age was 60.6 years (range 50 – 85 years). Fracture types were: acetabular wall and anterior column (n=8), anterior column and posterior hemi-transverse (n=2). All fresh fractures exhibited major acetabular damage associated with fracture of the femoral neck. A hybrid THA was used for all cases after fixation of the fracture. The femoral heads were used as graft material for deficient anterior columns in two patients and as “piecemeal” grafts for the others. Results: Mean follow-up was 36 months (range 24–35 months). At last follow-up all fractures had healed and all acetabular components exhibited solid fixation with no sign of migration. The mean outer diameter of the ace-tabular components inserted was 56 mm (52–64) using a 2 mm press-fit and one screw. The only complication was one postoperative anterior dislocation. Pain relief and function were satisfactory in all patients at last follow-up with a Postel Merle d’Aubigné score of 16 (13–18). Discussion: This anterior surgical approach enables good access to the acetabular walls and anterior columns, allowing solid fixation and relatively easy THA. The Kocher-Langenbech approach is still better in case of posterior deficiency or when posterior fixation requires space for inserting an acetabular component. We reserve it for THA used to treat fresh fractures of the acetabulum with major damage to the acetabulum and/or the femoral head, with or without neck fracture in patients aged 55 years or more. For differed reconstruction, we also use this approach if the acetabular damage involves the anterior column


Orthopaedic Proceedings
Vol. 86-B, Issue SUPP_II | Pages 168 - 168
1 Feb 2004
Peroulakis D Nikolakakis N Tintonis É Stamos K Chiotis I Eleuteropoulos A Mertzelos S Vandoros G
Full Access

Purpose: The use of femural head as an autograft in the reconstruction of dysplastic acetabulum is a fast, convinient and with excellent results throught time. Materlal-method: Since January 1986 until December 2002, 57 total hip replacements had taken place for dysplastic acetabulum. In all of them, the femural head has been used as an autograft. The age of the patients was between 42 to 75 years old (m.a. 63 ñ.Ï.). 45 of them were females and 12 males. 9 patients have been suggested to intertrïchanderic osteotomy in the past. One third of the patients had also the other hip affected. The surgical approach to the hip in all cases was made by the Harding’ s techique. The autograft in received from the femural neck. We prepared the acetabulum until we had bleeding bone. The bone graft is beared with two screws and if any gup exist is filled with cancellous autografts. In 41 operations of total hip replacements the cup was fixed with cement and in the rest 16 without. In our research we have included 43 hips with a follow-up from 3 to 14 years (m.a. 8,5 y.o.). Results: The results were evaluated with the Merle d’Aubigne and Postel scale. 5.6 pain, 4.1 wirdth of mobility. The callousness and the remodeling of the autograft were coplet in x-rays control. Íï case of absorbe of the bone graft. Until now no artrhoplasty has been revised. Conclusions: We consider that this is a satisflng method for filling and supporting the cup and in adittion it offers advantages in case that the artrhoplasty has to be revised


The Journal of Bone & Joint Surgery British Volume
Vol. 53-B, Issue 1 | Pages 23 - 29
1 Feb 1971
Hooper JC Jones EW

1. A study of fifty-nine patients with protrusion of the acetabulum showed that they fell into three age groups: those in their teens, those aged thirty-five to fifty years, and those presenting from fifty-one years onwards. 2. The juvenile age group was investigated clinically and biochemically but no causative metabolic factor was found. 3. The familial incidence was confirmed by radiological and biochemical surveys of several families. 4. The results of treatment show that when conservative treatment is insufficient a total hip replacement gives the best result from operation


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_IV | Pages 462 - 462
1 Nov 2011
Matsuo A Jingushi S Nakashima Y Yamamoto T Mawatari T Noguchi Y Shuto T Iwamoto Y
Full Access

Transposition osteotomy of the acetabulum (TOA) was the first periacetabular osteotomy for the osteoarthritis hips due to acetabular dysplasia, in which the acetabulum was transposed with articular cartilage. TOA improves coverage of the femoral head to restore congruity and stability, and also prevent further osteoarthritis deterioration and induce regeneration of the joint. Many good clinical outcomes have been reported for such periacetabular osteotomies for osteoarthritis of the hips at an early stage. In contrast, the clinical outcome is controversial for those hips at an advanced stage, in which the joint space has partly disappeared. The purpose of this study was to investigate whether TOA is an appropriate option for treatment of osteoarthritis of the hips at the advanced stage by comparing with matched control hips at the early stage. Between 1998 and 2001, TOA was performed in 104 hips of 98 patients. Sixteen of 17 hips (94%) with osteoarthritis at the advanced stage were examined and compared with 37 matched control hips at the early stage. The mean age at the operation was 48(38–56) and the mean follow-up period was 88 (65–107) months. TOA corrected the acetabular dysplasia and significantly improved containment of the femoral head. No hips had secondary operations including THA. Clinical scores were also significantly improved in both of the groups. In the advanced osteoarthritis cases, there was a tendency for abduction congruity before transposition osteotomy of the acetabulum to reflect the clinical outcome. TOA is a promising treatment option for the advanced osteoarthritis of the hips as well as for those patients at the early stage when preoperative radiographs show good congruity or containment of the joint