Results 1 - 50 of 1716
Results per page:
The Bone & Joint Journal
Vol. 102-B, Issue 6 Supple A | Pages 24 - 30
1 Jun 2020
Livermore AT Erickson JA Blackburn B Peters CL

Aims. A significant percentage of patients remain dissatisfied after total knee arthroplasty (TKA). The aim of this study was to determine whether the sequential addition of accelerometer-based navigation for femoral component preparation and sensor-guided ligament balancing improved complication rates, radiological alignment, or patient-reported outcomes (PROMs) compared with a historical control group using conventional instrumentation. Methods. This retrospective cohort study included 371 TKAs performed by a single surgeon sequentially. A historical control group, with the use of intramedullary guides for distal femoral resection and surgeon-guided ligament balancing, was compared with a group using accelerometer-based navigation for distal femoral resection and surgeon-guided balancing (group 1), and one using navigated femoral resection and sensor-guided balancing (group 2). Primary outcome measures were Patient-Reported Outcomes Measurement Information System (PROMIS) and Knee injury and Osteoarthritis Outcome (KOOS) scores measured preoperatively and at six weeks and 12 months postoperatively. The position of the components and the mechanical axis of the limb were measured postoperatively. The postoperative range of motion (ROM), haematocrit change, and complications were also recorded. Results. There were 194 patients in the control group, 103 in group 1, and 74 in group 2. There were no significant differences in baseline demographics between the groups. Patients in group 2 had significantly higher baseline mental health subscores than control and group 1 patients (53.2 vs 50.2 vs 50.2, p = 0.041). There were no significant differences in any PROMs at six weeks or 12 months postoperatively (p > 0.05). There was no difference in the rate of manipulation under anaesthesia (MUA), complication rates, postoperative ROM, or blood loss. There were fewer mechanical axis outliers in groups 1 and 2 (25.2%, 14.9% respectively) versus control (28.4%), but this was not statistically significant (p = 0.10). Conclusion. The sequential addition of navigation of the distal femoral cut and sensor-guided ligament balancing did not improve short-term PROMs, radiological outcomes, or complication rates compared with conventional techniques. The costs of these added technologies may not be justified. Cite this article: Bone Joint J 2020;102-B(6 Supple A):24–30


The Bone & Joint Journal
Vol. 99-B, Issue 2 | Pages 261 - 266
1 Feb 2017
Laitinen MK Parry MC Albergo JI Grimer RJ Jeys LM

Aims. Due to the complex anatomy of the pelvis, limb-sparing resections of pelvic tumours achieving adequate surgical margins, can often be difficult. The advent of computer navigation has improved the precision of resection of these lesions, though there is little evidence comparing resection with or without the assistance of navigation. Our aim was to evaluate the efficacy of navigation-assisted surgery for the resection of pelvic bone tumours involving the posterior ilium and sacrum. . Patients and Methods. Using our prospectively updated institutional database, we conducted a retrospective case control study of 21 patients who underwent resection of the posterior ilium and sacrum, for the treatment of a primary sarcoma of bone, between 1987 and 2015. The resection was performed with the assistance of navigation in nine patients and without navigation in 12. We assessed the accuracy of navigation-assisted surgery, as defined by the surgical margin and how this affects the rate of local recurrence, the disease-free survival and the effects on peri-and post-operative morbidity. . Results. The mean age of the patients was 36.4 years (15 to 66). The mean size of the tumour was 10.9 cm. In the navigation-assisted group, the margin was wide in two patients (16.7%), marginal in six (66.7%) and wide-contaminated in one (11.1%) with no intralesional margin. In the non-navigated-assisted group; the margin was wide in two patients (16.7%), marginal in five (41.7%), intralesional in three (25.0%) and wide-contaminated in two (16.7%). Local recurrence occurred in two patients in the navigation-assisted group (22.2%) and six in the non-navigation-assisted group (50.0%). The disease-free survival was significantly better when operated with navigation-assistance (p = 0.048). The blood loss and operating time were less in the navigated-assisted group, as was the risk of a foot drop post-operatively. Conclusion . The introduction of navigation-assisted surgery for the resection of tumours of the posterior ilium and sacrum has increased the safety for the patients and allows for a better oncological outcome. . Cite this article: Bone Joint J 2017;99-B:261–6


The Bone & Joint Journal
Vol. 102-B, Issue 1 | Pages 5 - 10
1 Jan 2020
Cawley DT Rajamani V Cawley M Selvadurai S Gibson A Molloy S

Aims. Intraoperative 3D navigation (ION) allows high accuracy to be achieved in spinal surgery, but poor workflow has prevented its widespread uptake. The technical demands on ION when used in patients with adolescent idiopathic scoliosis (AIS) are higher than for other more established indications. Lean principles have been applied to industry and to health care with good effects. While ensuring optimal accuracy of instrumentation and safety, the implementation of ION and its associated productivity was evaluated in this study for AIS surgery in order to enhance the workflow of this technique. The aim was to optimize the use of ION by the application of lean principles in AIS surgery. Methods. A total of 20 consecutive patients with AIS were treated with ION corrective spinal surgery. Both qualitative and quantitative analysis was performed with real-time modifications. Operating time, scan time, dose length product (measure of CT radiation exposure), use of fluoroscopy, the influence of the reference frame, blood loss, and neuromonitoring were assessed. Results. The greatest gains in productivity were in avoiding repeat intraoperative scans (a mean of 248 minutes for patients who had two scans, and a mean 180 minutes for those who had a single scan). Optimizing accuracy was the biggest factor influencing this, which was reliant on incremental changes to the operating setup and technique. Conclusion. The application of lean principles to the introduction of ION for AIS surgery helps assimilate this method into the environment of the operating theatre. Data and stakeholder analysis identified a reproducible technique for using ION for AIS surgery, reducing operating time, and radiation exposure. Cite this article: Bone Joint J. 2020;102-B(1):5–10


The Bone & Joint Journal
Vol. 98-B, Issue 5 | Pages 696 - 702
1 May 2016
Theologis AA Burch S Pekmezci M

Aims. We compared the accuracy, operating time and radiation exposure of the introduction of iliosacral screws using O-arm/Stealth Navigation and standard fluoroscopy. Materials and Methods. Iliosacral screws were introduced percutaneously into the first sacral body (S1) of ten human cadavers, four men and six women. The mean age was 77 years (58 to 85). Screws were introduced using a standard technique into the left side of S1 using C-Arm fluoroscopy and then into the right side using O-Arm/Stealth Navigation. The radiation was measured on the surgeon by dosimeters placed under a lead thyroid shield and apron, on a finger, a hat and on the cadavers. Results. There were no neuroforaminal breaches in either group. The set-up time for the O-Arm was significantly longer than for the C-Arm, while total time for placement of the screws was significantly shorter for the O-Arm than for the C-Arm (p = 0.001). The mean absorbed radiation dose during fluoroscopy was 1063 mRad (432.5 mRad to 4150 mRad). No radiation was detected on the surgeon during fluoroscopy, or when he left the room during the use of the O-Arm. The mean radiation detected on the cadavers was significantly higher in the O-Arm group (2710 mRem standard deviation (. sd. ) 1922) than during fluoroscopy (11.9 mRem . sd 14.8). (p < 0.01). Conclusion. O-Arm/Stealth Navigation allows for faster percutaneous placement of iliosacral screws in a radiation-free environment for surgeons, albeit with the same accuracy and significantly more radiation exposure to cadavers, when compared with standard fluoroscopy. Take home message: Placement of iliosacral screws with O-Arm/Stealth Navigation can be performed safely and effectively. Cite this article: Bone Joint J 2016;98-B:696–702


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 9 | Pages 1234 - 1240
1 Sep 2012
Willcox NMJ Clarke JV Smith BRK Deakin AH Deep K

We compared lower limb coronal alignment measurements obtained pre- and post-operatively with long-leg radiographs and computer navigation in patients undergoing primary total knee replacement (TKR). A series of 185 patients had their pre- and post-implant radiological and computer-navigation system measurements of coronal alignment compared using the Bland-Altman method. The study included 81 men and 104 women with a mean age of 68.5 years (32 to 87) and a mean body mass index of 31.7 kg/m. 2. (19 to 49). Pre-implant Bland–Altman limits of agreement were -9.4° to 8.6° with a repeatability coefficient of 9.0°. The Bland–Altman plot showed a tendency for the radiological measurement to indicate a higher level of pre-operative deformity than the corresponding navigation measurement. Post-implant limits of agreement were -5.0° to 5.4° with a repeatability coefficient of 5.2°. The tendency for valgus knees to have greater deformity on the radiograph was still seen, but was weaker for varus knees. . The alignment seen or measured intra-operatively during TKR is not necessarily the same as the deformity seen on a standing long-leg radiograph either pre- or post-operatively. Further investigation into the effect of weight-bearing and surgical exposure of the joint on the mechanical femorotibial angle is required to enable the most appropriate intra-operative alignment to be selected


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_5 | Pages 77 - 77
1 Apr 2019
Sawada N Yabuno K Ikeda S Kanazawa M
Full Access

INTRODUCTION. In gap balancing technique, we decided the femoral component rotation according to the ligament balance in flexion. Component and limb alignment are important considerations during TKA. Three-dimensional positioning of TKA implants and exact mechanical axis has an effect on implant loosening, polyethylene stresses, and gait. According to the recent report, the navigation system made it possible to achieve aligned implants more than conventional TKA. Hybrid Navigation technique which is our procedure is combination of navigation system and modified gap technique. In other words, exact mechanical axis is gained by navigation system, stable stability of knee joint is gained by modified gap technique. PURPOSE. The purpose of this study is to carry out clinical evaluation and image evaluation of the patients who underwent hybrid navigation technique TKA. METHODS. We performed TKA using the hybrid navigation technique in 100 knees from April 2012 to April 2015. We evaluated hybrid navigation TKA which we were able to follow up more than five years. 33 knees were available for follow up. We investigated the mid-term results of TKA after a mean follow up period of 5 years and 8 months. We evaluated range of motion(ROM), Japan Orthopaedic Association (JOA)score, complications, revision rate as clinical evaluations. And we evaluated radiolucent line(RLL), loosening in X-ray, implantation accuracy in computed tomography(CT) as image evaluations. Surgical technique was that the knees were exposed using a medial parapatellar approach without patella turnover, and the anterior and posterior cruciate ligaments were resected. And next osteotomy distal femur and proximal tibia using CT-free Navigation, step-wise medial soft tissue release was performed to make the rectangular extension joint gap using gap tensor space (off set balancer) at 40 pounds of distraction force. Flextion gap was made at the same distraction force, thereby we determined external rotation angle of femur osteotomy in a patella reduction position. CT of the whole leg was taken preoperation and postoperation the first postoperative week in all cases. RESULTS. In CT evaluation, coronal and sagittal alignments of femoral componet were mean 90.92° and mean flex 3.02°. These alignment of tibial componet were 90.54° and mean posterior slope 3.0°. Outliers(>3°)of coronal aligment were 6% (2 knees)in femoral componet, and 6%(2 knees) in tibial componet. In clinical evaluation, mean preoperative ROM(flex) was 105 degrees which improved 122 degrees at final follow up. Mean preoperative JOA score was 46.3 which improved 85.8 at final follow up. In image evaluation, there were no incidence of component loosening(RLL>2mm). We experienced two complications(1 deep infection and 1 intraoperative fracture), but there were no postoperative fracture and DVT/PE. The revision arte was 3%(1 knee) due to deep infection. DISCUSSION AND CONCLUSION. Mid-term postoperative results has shown a good prognosis. We will not understand that we do not observe long-term results in future, neverthless we believe that this technique should be considered as an alternative means of conducting TKA


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_4 | Pages 53 - 53
1 Feb 2017
Kawamoto T Iida S Suzuki C
Full Access

Background. Variability in component alignment continues to be a major in total knee arthroplasty(TKA). In the long term, coronal plane malalignment has been associated with an increased risk of loosening, insatability, and wear. Recently portable navigation system(PNS) in TKA have been introduced. The goal of PNS are to improve the accuracy of post operative alignment and eliminate outlier cases. The aim of this study is to evaluate clinical results and quantify the coronal plane alignment between a group of patients who underwent TKA using PNS versus CT-free large-console navigation system. Patients and Method. An unselected consecutive series of ninety-four patients undergoing primary TKA using the cruciate retaining cemented total knee system between April 2012 and August 2015 were studied. Patients were included only if they were deemed to be candidates for a Cruciate retaining TKA. Patients were excluded if they had a flexion contracture greater than 40°, or severe valgus or varus deformity. Forty eight knees was operated a TKA with CT-free large-console navigation system(The OrthoPilot system; Aesculap, Tuttlingen, Germany). Subsequently forty six knees was received a TKA using portable navigation system (KneeAlign2. TM. ). Postoperatively standing AP hip-to-ankle radiographs were obtained, from which the lower extremity mechanical axis, component angle were measured. The alignment goals were a neutral mechanical axis defined as a hip-to-ankle angle of 0°with the femoral and tibial components aligned perpendicular to the mechanical axis. The total operating time were quantified utilising an operating room database. The total operating time between TKAs performed with CT-free navigation system and those performed with portable navigation system was compared in each group. All patients postoperatively was evaluated of clinical results the Japan Orthopedics Association(JOA) Knee scores. Results. The mechanical axis angle in PNS group was 0.8°, while the CT-free navigation system group was 1.6°and there was no statistical significance. The number of outliers for mechanical axis angle was PNS group 39.1%, the large-console navigation group 22.9%, between the two groups there was statistical significance. The operative time in PNS was 130.0 minutes and significantly less compared to the time of the large-console group 150.4 minutes. The JOA Knee score of navigation group was 83.9 points, and the score of PNS group was 81.0 points., there was no statistical significance between the two groups on the clinical score. Conclusion. portable navigation system improved operative time in TKA, this study demonstrates portable navigation system to obtain same angle of overall mechanical axis angle as large-console group navigation system


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_10 | Pages 17 - 17
1 May 2016
Sawada N Yabuno K Kanazawa M
Full Access

INTRODUCTION. Soft-tissue balancing of the knee is fundamental to the success of total knee arthroplasty(TKA). Preparing rectangular extension and flexion joint gaps in the most important goal in TKA, because it facilitates functional stability of the knee. In gap balancing technique, we decided the femoral component rotation according to the ligament balance in flexion. Component and limb alignment are important considerations during TKA. Three-dimensional positioning of TKA implants and exact mechanical axis has an effect on implant loosening, polyethylene stresses, and gait. According to the recent reports, the navigation system made it possible to achieve aligned implants more than conventional TKA. Hybrid Navigation technique which is our procedure is combination of navigation system and modified gap technique. In other words, exact mechanical axis is gained by navigation system, stable stability of knee joint is gained by modified gap technique. PURPOSE. The purpose of this study is to carry out clinical evaluation and image assenssment using computed tomography (CT) of the patients who underwent hybrid navigation technique TKA. METHODS. We performed TKA using the hybrid navigation technique in 100 knees from April 2012. Surgical technique was that the knees were exposed using a medial parapatellar approach without patella turnover, and the anterior and posterior cruciate ligaments were resected. And next osteotomy distal femur and proximal tibia using CT-free Navigation, step-wise medial soft tissue release was performed to make the rectangular extension joint gap using gap tensor space(off set balancer) at 40 pounds of distraction force. Flextion gap was made at the same distraction force, thereby we determined external rotation angle of femur osteotomy in a patella reduction position. See Figure 1. CT of the whole leg was taken preoperation and postoperation in all cases. RESULTS. Coronal and sagittal alignments of femoral componet angle were mean 91.05° and mean flex anglewere 2.98°. These alignment of tibial componet angle were 91.08° and mean posterior slope angle were 3.38°. Outliers(>3°)of coronal aligment were 9% in femoral componet, and 8% in tibial componet. Mean operation times(skin incision to skin closure) were 108 minutes. We experienced two complications(1 deep infection and 1 peroneal nerve palsy), but there were no intraoperative fracture, postoperative fracture and DVT/PE. DISCUSSION AND CONCLUSION. 100 patients underwent hybrid navigation TKA which has advantage of both navigation and gap technique. CT assessment of components has shown good results. (outlier>3°femoral component: 9%, tibial component 8%) Short-term postoperative results has shown a good prognosis. We will not understand that we do not observe long-term results in future, neverthless we believe that this technique should be considered as an alternative means of conducting TKA


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_2 | Pages 105 - 105
10 Feb 2023
Xu J Veltman W Chai Y Walter W
Full Access

Navigation in total hip arthroplasty has been shown to improve acetabular positioning and can decrease the incidence of mal-positioned acetabular components. The aim of this study was to assess two surgical guidance systems by comparing intra-operative measurements of acetabular component inclination and anteversion with a post-operative CT scan. We prospectively collected intra-operative navigation data from 102 hips receiving conventional THA or hip resurfacing arthroplasty through either a direct anterior or posterior approach. Two guidance systems were used simultaneously: an inertial navigation system (INS) and optical navigation system (ONS). Acetabular component anteversion and inclination was measured on a post-operative CT. The average age of the patients was 64 years (range: 24-92) and average BMI was 27 kg/m. 2. (range 19-38). 52% had hip surgery through an anterior approach. 98% of the INS measurements and 88% of the ONS measurements were within 10° of the CT measurements. The mean (and standard deviation) of the absolute difference between the post-operative CT and the intra-operative measurements for inclination and anteversion were 3.0° (2.8) and 4.5° (3.2) respectively for the ONS, along with 2.1° (2.3) and 2.4° (2.1) respectively for the INS. There was significantly lower mean absolute difference to CT for the INS when compared to ONS in both anteversion (p<0.001) and inclination (p=0.02). Both types of navigation produced reliable and reproducible acetabular cup positioning. It is important that patient-specific planning and navigation are used together to ensure that surgeons are targeting the optimal acetabular cup position. This assistance with cup positioning can provide benefits over free-hand techniques, especially in patients with an altered acetabular structure or extensive acetabular bone loss. In conclusion, both ONS and INS allowed for adequate acetabular positioning as measured on postoperative CT, and thus provide reliable intraoperative feedback for optimal acetabular component placement


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_IV | Pages 456 - 457
1 Nov 2011
Garvin KL Barrera OA Haider H
Full Access

Computer aided orthopaedic surgical (CAOS) technology has been around for over 20 years, and while it appears to provide better outcomes compared to conventional jigs, less than 1% of orthopaedic surgeons in USA have adopted it. This study surveyed the arguments against CAOS usage, highlighting those reasons which may continue to prevent CAOS from becoming truly widely accepted. The survey has identified several concerns with navigation systems. For example, the pin tracts from navigation reference frames cause stress risers that increase the risk of bone fracture and soft tissue/muscle damage. Additionally, infrared trackers take footprint space (as they require line of sight access to the tracking camera), increase risk of infection, and present a potential distraction to the surgical team. With current CAOS systems, even more nstrumentation is needed than with non-navigated surgical systems, and it is arguable that navigation makes surgery more complex, requiring a knowledge of anatomic landmarks, an increased number of tasks prior to and during surgery, and an assortment of different and perhaps unfamiliar instruments. These complexities very likely result in a slow learning curve on current CAOS systems, a learning curve that is mostly not started by the majority of surgeons. Other items of concern are the accuracy of morphed/generated bones in imageless systems (and how these models assume non-deformed anatomy), inaccuracies or distortion of the measurements (operating room lighting interfering with infrared trackers or field deformation of electromagnetic systems due to ferromagnetic instruments at the surgical site) and computer reliability. Considering the high cost (or low cost-effectiveness) of integrating CAOS into arthroplasty, and the lack of enough studies documenting truly better long term clinical results or fewer actual complications, it is evident why navigation is not yet a popular option for TKR. As a result of the critical findings from this study, it is our view that any successful new technique/tool in surgery should make the overall procedure easier, faster, cheaper and better (or at least equally as good) as the current techniques. While robotic surgery seems to be re-emerging, we hypothesize that the next real breakthrough will come from newer more utilitarian light weight small foot print technologies actuated by surgeons themselves, with enhanced computer guidance that will allow them to reduce instrumentation, complexity, and surgical time such as navigated free-hand bone cutting. Alternative navigation technologies (e.g. UWB 3D positioning radar) where line of sight becomes less crucial, image based systems (rather than image free), artificial vision, and smart instrumentation are likely to play a major role in achieving widespread future acceptance of CAOS in TKR


Orthopaedic Proceedings
Vol. 91-B, Issue SUPP_III | Pages 394 - 394
1 Sep 2009
Seon J Song E Park S Cho S Cho S Yoon T
Full Access

Correct alignment of the leg and positioning of the implant has shown to be an important factor in the successful long term outcome of total knee arthroplasty and navigation systems enable an accuracy of corrections and alignment within intervals of 1 mm or 1 degree. This study is to test if there is any discrepancy in accuracy which was sometimes observed in clinical trials between Orthopilot (Aesculap, Tuttlingen, German) and AxiEM (Medtronic Navigation, CoalCreek, Colo., USA). A synthetic bone model (Sawbones, Pacific Laboratories, Vashon, Washington) including pelvis and leg with mobile joint made up of titanium which does not affect the electromagnetic field was constructed. Mechanical axis was checked by ORTHODOC system (Integrated Surgical System, CA, USA) that is a preplanning system for ROBODOC (ISS, CA, USA) assisted total knee arthroplasty (TKA) and total hip arthroplasty (THA). The CT images were scanned with 1.25 mm or less slice interval. The CT images were converted to 3-dimensional (3D) volume-rendered model in ORTHODOC. Two orthopaedic surgeons measured it ten times independently. For the measurement of mechanical axis using navigation, 4 orthopaedic surgeons (two experts having more than 100 navigation experiences and two residents) registered anatomical landmarks and kinematic center of bone model ten times using Orthopilot as well as AxiEM. After that, one surgeon intentionally registered the wrong anatomical landmarks (10 mm medial and lateral to the center of distal femur, proximal tibial and ankle, and both malleoli) in both navigation system and observed the change of mechanical axis. True mechanical axis was varus 1.25° using Orthodoc, Orthopilot displayed varus 1.10±0.64° and AxiEM did varus 1.78±0.79°. The difference of mechanical axis between two navigations was not observed (P=0.12) and there were no intra and inter-observer variation in statistical analysis (Correlation=0.934, P=0.00). In the case of erroneous identification of the anatomical landmarks, Orthipilot showed much less variation compared to AxiEM. AxiEM altered the mechanical axis more in palpating center of the distal femur and ankle center and Orthopilot did in palpating the center of ankle. Both navigation systems provide high accuracy and reproducibility of mechanical axis of lower limb in experimental condition. But both were affected by the wrong identification of the anatomical landmarks. AxiEM had more variations. So surgeon should pay attention to register the precise anatomical landmarks


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_12 | Pages 62 - 62
23 Jun 2023
Inaba Y Tezuka T Choe H Ike H
Full Access

Rotational acetabular osteotomy (RAO), one of periacetabular osteotomies, is an effective joint-preserving surgical treatment for developmental dysplasia of the hip. Since 2013, we have been using a CT-based navigation for RAO to perform safe and accurate osteotomy. CT-based navigation allows precise osteotomy during surgery but cannot track the bony fragment after osteotomy. Thus, it is an issue to achieve successful reorientation in accordance with preoperative planning. In this presentation, we introduce a new method to achieve reorientation and evaluate its accuracy. Thirty joints in which CT-based navigated RAO was performed were included in this study. For the first 20 joints, reorientation was confirmed by tracing the lateral aspect of rotated fragment with navigation and checked if it matched with the preoperative planning. For the latter 10 joints, a new method was adopted. Four fiducial points were made on lateral side of the acetabulum in the preoperative 3-dimensional model and intraoperatively, rotation of the osteotomized bone was performed so that the 4 fiducial points match the preoperative plan. To assess the accuracy of position of rotated fragment in each group, preoperative planning and postoperative CT were compared. A total of 24 radial reformat images of postoperative CT were obtained at a half-hour interval following the clockface system around the acetabulum. In every radial image, femoral head coverage of actual postop- and planned were measured to evaluate the accuracy of acetabular fragment repositioning. The 4-fiducial method significantly reduced the reorientation error. Especially in the 12:00 to 1:00 position of the acetabulum, there were significantly fewer errors (p<0.01) and fewer cases with under-correction of the lateral acetabular coverage. With the new method with 4 reference fiducials, reorientation of the acetabulum could be obtained as planned with lesser errors


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_15 | Pages 339 - 339
1 Mar 2013
Nam D Weeks D Reinhardt K Nawabi DH Cross MB Mayman DJ Su E
Full Access

Introduction. Computer assisted surgery (CAS) systems have been shown to improve alignment accuracy in total knee arthroplasty (TKA), yet concerns regarding increased costs, operative times, pin sites, and the learning curve associated with CAS techniques have limited its widespread acceptance. The purpose of this study was to compare the alignment accuracy of an accelerometer-based, portable navigation device (KneeAlignÒ 2) to a large console, imageless CAS system (AchieveCAS). Our hypothesis is that no significant difference in alignment accuracy will be appreciated between the portable, accelerometer-based system, and the large-console, imageless navigation system. Methods. 62 consecutive patients, and a total of 80 knees, received a posterior cruciate substituting TKA using the Achieve CAS computer navigation system. Subsequently, 65 consecutive patients, and a total of 80 knees, received a posterior cruciate substituting TKA using the KneeAlignÒ 2 to perform both the distal femoral and proximal tibial resections (femoral guide seen in Figure 1, and tibial guide seen in Figure 2). Postoperatively, standing AP hip-to-ankle radiographs were obtained for each patient, from which the lower extremity mechanical axis, tibial component varus/valgus mechanical alignment, and femoral component varus/valgus mechanical alignment were digitally measured. Each measurement was performed by two, blinded independent observers, and interclass correlation for each measurement was calculated. All procedures were performed using a thigh pneumatic tourniquet, and the total tourniquet time for each procedure was recorded. Results. In the KneeAlignÒ 2 cohort, 92.5% of patients had an alignment within 3° of a neutral mechanical axis (vs. 86.3% with AchieveCAS, p<0.01), 96.2% had a tibial component alignment within 2° of perpendicular to the tibial mechanical axis (vs. 97.5% with AchieveCAS, p=0.8), and 94.9% had a femoral component alignment within 2° of perpendicular to the femoral mechanical axis (vs. 92.5% with AchieveCAS, p<0.01). The mean tourniquet time in the KneeAlignÒ 2 cohort was 48.1 + 10.2 minutes, versus 54.1 + 10.5 in the AchieveCAS cohort (p<0.01). The interclass correlation coefficient for measurement of the postoperative tibial alignment was 0.92, for femoral alignment was 0.85, and for overall lower extremity alignment was 0.94. Conclusion. Accelerometer-based, portable navigation can provide the same degree of alignment accuracy as large console, imageless CAS system in TKA, while also decreasing operative times. The KneeAlignÒ 2 successfully combines the benefits and accuracy of large-console, CAS systems, while avoiding the use of extra pin sites, decreasing operative times, and providing a level of familiarity with conventional alignment methods


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_2 | Pages 64 - 64
10 Feb 2023
Lourens E Kurmis A Harries D de Steiger RN
Full Access

Total hip arthroplasty (THA) is an effective treatment for symptomatic hip osteoarthritis (OA). While computer-navigation technologies in total knee arthroplasty show survivorship advantages and are widely used, comparable applications within THA show far lower utilisation. Using national registry data, this study compared patient reported outcome measures (PROMs) in patients who underwent THA with and without computer navigation. Data from Australian Orthopaedic Association National Joint Replacement Registry (AOANJRR) PROMs program included all primary THA procedures performed for OA up to 31 December 2020. Procedures using the Intellijoint HIP® navigation system were identified and compared to procedures using other computer navigation systems or conventional instrumentation only. Changes in PROM scores between pre-operative and 6-month post-operative time points were analysed using multiple regression model, adjusting for pre-operative score, patient age, gender, ASA score, BMI, surgical approach, and hospital type. There were 65 primary THA procedures that used the Intellijoint HIP® system, 90 procedures used other types of computer navigation, and the remaining 5,284 primary THA procedures used conventional instrumentation. The estimated mean changes in the EuroQol visual analogue scale (EQ VAS) score and Oxford Hip score did not differ significantly when Intellijoint® was compared to conventional instruments (estimated differences of 2.4, 95% CI [-1.7, 6.5], p = 0.245, and −0.5, 95% CI [-2.5, 1.4], p = 0.592, respectively). The proportion of patients who were satisfied with their procedure was also similar when Intellijoint® was compared to conventional instruments (rate ratio 1.06, 95% CI [0.97, 1.16], p = 0.227). The preliminary data demonstrate no significant difference in PROMs when comparing the Intellijoint HIP® THA navigation system with both other navigation systems and conventional instrumentation for primary THAs performed for OA. Level of evidence: III (National registry analysis)


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_9 | Pages 5 - 5
1 Jun 2021
Muir J Dundon J Paprosky W Schwarzkopf R Barlow B Vigdorchik J
Full Access

Introduction. Re-revision due to instability and dislocation can occur in up to 1 in 4 cases following revision total hip arthroplasty (THA). Optimal placement of components during revision surgery is thus critical in avoiding re-revision. Computer-assisted navigation has been shown to improve the accuracy and precision of component placement in primary THA; however, its role in revision surgery is less well documented. The purpose of our study was to evaluate the effect of computer-assisted navigation on component placement in revision total hip arthroplasty, as compared with conventional surgery. Methods. To examine the effect of navigation on acetabular component placement in revision THA, we retrospectively reviewed data from a multi-centre cohort of 128 patients having undergone revision THA between March 2017 and January 2019. An imageless computer navigation device (Intellijoint HIP®, Intellijoint Surgical, Kitchener, ON, Canada) was utilized in 69 surgeries and conventional methods were used in 59 surgeries. Acetabular component placement (anteversion, inclination) and the proportion of acetabular components placed in a functional safe zone (40° inclination/20° anteversion) were compared between navigation assisted and conventional THA groups. Results. Mean inclination decreased post-operatively versus baseline in both the navigation (44.9°±12.1° vs. 43.0°±6.8°, p=0.65) and control (45.8°±19.4° vs. 42.8°±7.1°, p=0.08) groups. Mean anteversion increased in both study groups, with a significant increase noted in the navigation group (18.6°±8.5° vs. 21.6°±7.8°, p=0.04) but not in the control group (19.4°±9.6° vs. 21.2°±9.8°, p=0.33). Post-operatively, a greater proportion of acetabular components were within ±10° of a functional target (40° inclination, 20° anteversion) in the navigation group (inclination: 59/67 (88%), anteversion: 56/67 (84%)) than in the control group (49/59 (83%) and 41/59, (69%), respectively). Acetabular component precision in both study groups improved post-operatively versus baseline. Variance in inclination improved significantly in both control (50.6° vs. 112.4°, p=0.002) and navigation (46.2° vs. 141.1°, p<0.001) groups. Anteversion variance worsened in the control group (96.3° vs. 87.6°, p=0.36) but the navigation group showed improvement (61.2° vs. 72.7°, p=0.25). Post-operative variance amongst cup orientations in the navigation group (IN: 46.2°; AV: 61.2°) indicated significantly better precision than that observed in the control group (IN: 50.6°, p=0.36; AV: 96.3°, p=0.04). Discussion. Re-revision is required in up to 25% of revision THA cases, of which 36% are caused by instability. This places a significant burden on the health care system and highlights the importance of accurate component placement. Our data indicate that the use of imageless navigation in revision THA – by minimizing the likelihood of outliers – may contribute to lower rates of re-revision by improving component orientation in revision THA. Conclusion. Utilizing imageless navigation in revision THAs results in more consistent placement of the acetabular component as compared to non-navigated revision surgeries


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_9 | Pages 4 - 4
1 Jun 2021
Jenny J Banks S Baldairon F
Full Access

INTRODUCTION. The restoration of physiological kinematics is one of the goals of a total knee arthroplasty (TKA). Navigation systems have been developed to allow an accurate and precise placement of the implants. But its application to the intraoperative measurement of knee kinematics has not been validated. The hypothesis of this study was that the measurement of the knee axis, femoral rotation, femoral translation with respect to the tibia, and medial and lateral femorotibial gaps during continuous passive knee flexion by the navigation system would be different from that by fluoroscopy taken as reference. MATERIAL – METHODS. Five pairs of knees of preserved specimens were used. The e.Motion FP ® TKA (B-Braun Aesculap, Tuttlingen, Germany) was implanted using the OrthoPilot TKA 4.3 version and Kobe version navigation system (B-Braun Aesculap, Tuttlingen, Germany). Kinematic recording by the navigation system was performed simultaneously with fluoroscopic recording during a continuous passive flexion-extension movement of the prosthetic knee. Kinematic parameters were extracted from the fluoroscopic recordings by image processing using JointTrack Auto ® software (University of Florida, Gainesville, USA). The main criteria were the axis of the knee measured by the angle between the center of the femoral head, the center of the knee and the center of the ankle (HKA), femoral rotation, femoral translation with respect to the tibia, and medial and lateral femorotibial gaps. The data analysis was performed by a Kappa correlation test. The agreement of the measurements was assessed using the intraclass correlation coefficient (ICC) and its 95% confidence interval. RESULTS. The respective CCIs were as follows: HKA angle 0.839 [0.820; 0.856]; femoral translation 0.560 [0.517; 0.600]; femoral rotation 0.652 [0.616; 0.686]; medial femorotibial gap 0.905 [0.894; 0.916]; lateral femorotibial gap 0.767 [0.740; 0.791]. DISCUSSION. Measurements of TKA kinematics by the navigation system and by fluoroscopy were consistent for HKA angle and medial and lateral femorotibial gaps, but not for femoral translation and femoral rotation. These differences can be explained by a methodological bias. At the end of this work, the specific navigation system cannot be considered as a reliable instrument for measuring the kinematics of a TKA


Bone & Joint Open
Vol. 3, Issue 6 | Pages 475 - 484
13 Jun 2022
Jang SJ Vigdorchik JM Windsor EW Schwarzkopf R Mayman DJ Sculco PK

Aims. Navigation devices are designed to improve a surgeon’s accuracy in positioning the acetabular and femoral components in total hip arthroplasty (THA). The purpose of this study was to both evaluate the accuracy of an optical computer-assisted surgery (CAS) navigation system and determine whether preoperative spinopelvic mobility (categorized as hypermobile, normal, or stiff) increased the risk of acetabular component placement error. Methods. A total of 356 patients undergoing primary THA were prospectively enrolled from November 2016 to March 2018. Clinically relevant error using the CAS system was defined as a difference of > 5° between CAS and 3D radiological reconstruction measurements for acetabular component inclination and anteversion. Univariate and multiple logistic regression analyses were conducted to determine whether hypermobile (. Δ. sacral slope(SS). stand-sit. > 30°), or stiff (. ∆. SS. stand-sit. < 10°) spinopelvic mobility contributed to increased error rates. Results. The paired absolute difference between CAS and postoperative imaging measurements was 2.3° (standard deviation (SD) 2.6°) for inclination and 3.1° (SD 4.2°) for anteversion. Using a target zone of 40° (± 10°) (inclination) and 20° (± 10°) (anteversion), postoperative standing radiographs measured 96% of acetabular components within the target zone for both inclination and anteversion. Multiple logistic regression analysis controlling for BMI and sex revealed that hypermobile spinopelvic mobility significantly increased error rates for anteversion (odds ratio (OR) 2.48, p = 0.009) and inclination (OR 2.44, p = 0.016), whereas stiff spinopelvic mobility increased error rates for anteversion (OR 1.97, p = 0.028). There were no dislocations at a minimum three-year follow-up. Conclusion. Despite high reliability in acetabular positioning for inclination in a large patient cohort using an optical CAS system, hypermobile and stiff spinopelvic mobility significantly increased the risk of clinically relevant errors. In patients with abnormal spinopelvic mobility, CAS systems should be adjusted for use to avoid acetabular component misalignment and subsequent risk for long-term dislocation. Cite this article: Bone Jt Open 2022;3(6):475–484


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_1 | Pages 9 - 9
2 Jan 2024
Vadalà G Papalia G Russo F Ambrosio L Franco D Brigato P Papalia R Denaro V
Full Access

The use of intraoperative navigation and robotic surgery for minimally invasive lumbar fusion has been increasing over the past decade. The aim of this study is to evaluate postoperative clinical outcomes, intraoperative parameters, and accuracy of pedicle screw insertion guided by intraoperative navigation in patients undergoing lumbar interbody fusion for spondylolisthesis. Patients who underwent posterior lumbar fusion interbody using intraoperative 3D navigation since December 2021 were included. Visual Analogue Scale (VAS), Oswestry Disability Index (ODI), and Short Form Health Survey-36 (SF-36) were assessed preoperatively and postoperatively at 1, 3, and 6 months. Screw placement accuracy, measured by Gertzbein and Robbins classification, and facet joint infringement, measured by Yson classification, were assessed by intraoperative Cone Beam CT scans performed at the end of instrumentation. Finally, operation time, intraoperative blood loss, hospital stay, and screw insertion time were evaluated. This study involved 50 patients with a mean age of 63.7 years. VAS decreased from 65.8±23 to 20±22 (p<.01). ODI decreased from 35.4%±15 to 11.8%±14 (p<.01). An increase of SF-36 from 51.5±14 to 76±13 (p<.01) was demonstrated. The accuracy of “perfect” and “clinically acceptable” pedicle screw fixation was 89.5% and 98.4%, respectively. Regarding facet violation, 96.8% of the screws were at grade 0. Finally, the average screw insertion time was 4.3±2 min, hospital stay was 4.2±0.8 days, operation time was 205±53 min, and blood loss was 169±107 ml. Finally, a statistically significant correlation of operation time with hospital stay, blood loss and placement time per screw was found. We demonstrated excellent results for accuracy of pedicle screw fixation and violation of facet joints. VAS, ODI and SF-36 showed statistically significant improvements from the control at one month after surgery. Navigation with intraoperative 3D images represents an effective system to improve operative performance in the surgical treatment of spondylolisthesis


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_2 | Pages 34 - 34
10 Feb 2023
Farey J Chai Y Xu J Sadeghpour A Marsden-Jones D Baker N Vigdorchik J Walter W
Full Access

Imageless computer navigation systems have the potential to improve acetabular cup position in total hip arthroplasty (THA), thereby reducing the risk of revision surgery. This study aimed to evaluate the accuracy of three alternate registration planes in the supine surgical position generated using imageless navigation for patients undergoing THA via the direct anterior approach (DAA). Fifty-one participants who underwent a primary THA for osteoarthritis were assessed in the supine position using both optical and inertial sensor imageless navigation systems. Three registration planes were recorded: the anterior pelvic plane (APP) method, the anterior superior iliac spines (ASIS) functional method, and the Table Tilt (TT) functional method. Post-operative acetabular cup position was assessed using CT scans and converted to radiographic inclination and anteversion. Two repeated measures analysis of variance (ANOVA) and Bland-Altman plots were used to assess errors and agreement of the final cup position. For inclination, the mean absolute error was lower using the TT functional method (2.4°±1.7°) than the ASIS functional method (2.8°±1.7°, ρ = .17), and the ASIS anatomic method (3.7°±2.1, ρ < .001). For anteversion, the mean absolute error was significantly lower for the TT functional method (2.4°±1.8°) than the ASIS functional method (3.9°±3.2°, ρ = .005), and the ASIS anatomic method (9.1°±6.2°, ρ < .001). All measurements were within ± 10° for the TT method, but not the ASIS functional or APP methods. A functional registration plane is preferable to an anatomic reference plane to measure intra-operative acetabular cup inclination and anteversion accurately. Accuracy may be further improved by registering patient location using their position on the operating table rather than anatomic landmarks, particularly if a tighter target window of ± 5° is desired


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_9 | Pages 17 - 17
1 Jun 2021
Lane P Murphy W Harris S Murphy S
Full Access

Problem. Total hip replacement (THA) is among the most common and highest total spend elective operations in the United States. However, up to 7% of patients have 90-day complications after surgery, most frequently joint dislocation that is related to poor acetabular component positioning. These complications lead to patient morbidity and mortality, as well as significant cost to the health system. As such, surgeons and hospitals value navigation technology, but existing solutions including robotics and optical navigation are costly, time-consuming, and complex to learn, resulting in limited uptake globally. Solution. Augmented reality represents a navigation solution that is rapid, accurate, intuitive, easy to learn, and does not require large and costly equipment in the operating room. In addition to providing cutting edge technology to specialty orthopedic centers, augmented reality is a very attractive solution for lower volume and smaller operative settings such as ambulatory surgery centers that cannot justify purchases of large capital equipment navigation systems. Product. HipInsight™ is an augmented reality solution for navigation of the acetabular component in THA. HipInsight is a navigation solution that includes preoperative, cloud based surgical planning based on patient imaging and surgeon preference of implants as well as intraoperative guidance for placement of the acetabular component. Once the patient specific surgical plan is generated on the cloud-based planning system, holograms showing the optimal planned position of the acetabular component are exported in holographic format to a Microsoft HoloLens 2™, which the surgeon wears during placement of the acetabular component in total hip arthroplasty. The pelvis is registered using the HipXpert™ mechanical registration device, which takes 2–3 minutes to dock in the operating room. The surgeon then is able to view the patient's anatomy and optimal placement of the acetabular component under the skin in augmented reality. The surgeon then aligns the real cup impactor with the augmented reality projection of the cup impactor resulting in precise placement of the cup. Timescales. HipInsight was FDA cleared on January 28, 2021 for intraoperative use for placement of the acetabular component in total hip arthroplasty. The first case was performed in February 2021, and the product was launched to a select group of orthopedic surgeons in March 2021. Funding. HipInsight has been self-funded to date, and is beginning to engage in discussions to raise capital for a rapidly scaling commercial launch


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_I | Pages 110 - 111
1 Mar 2010
Iwaki H Minoda Y Ikebuchi M Fukunaga K Iida T Takaoka K
Full Access

Cup orientation of total hip arthroplasty (THA) is critical for dislocation, range of motion, polyethylene wear, pelvic osteolysis, and component migration. But, substantial error under manual technique has been reported. Therefore, various navigation systems were introduced to reduce outliers. CT based navigation (CTN) was reported to reduce outliers in cup orientation. Recently, a noble technique, fluoroscopy-CT-based navigation (FCTN), has recently been developed using 2D-3D matching technique. Because of much less registration points, FCTN might be friendly to MIS THA and cases with sever bone deformity. Between October 2006 and April 2008, 33 THAs were performed through MIS approach with navigations. We prospectively randomized those into two groups, CTN and FCTN groups. We implanted cementless hemispherical cups in 18 hips using CTN (VectorVision CT Hip 3.1) and in 15 hips using FCTN (VectorVision CT Hip 3.5). For all the patients, volumetric post-operative CT scan was performed to measure 3D cup orientation. using 3D image-processing software (JMM, Japan). The difference from target angles of anteversion was 2.7 ± 2.4 degrees in FCTN group, and 12.1 ± 5.7 degrees in CTN group (p < 0.001). The absolute value of difference from target angles of inclination was 2.7 ± 2.4 degrees in FCTN group, and 6.5 ± 4.5 degrees in CTN group (p = 0.006). FCTN does not need surface registration around acetabulum, which is great advantage to MIS THA. Our study clearly showed that FCTN significantly improved a cup orientation to CTN


Bone & Joint Research
Vol. 6, Issue 3 | Pages 137 - 143
1 Mar 2017
Cho HS Park YK Gupta S Yoon C Han I Kim H Choi H Hong J

Objectives. We evaluated the accuracy of augmented reality (AR)-based navigation assistance through simulation of bone tumours in a pig femur model. Methods. We developed an AR-based navigation system for bone tumour resection, which could be used on a tablet PC. To simulate a bone tumour in the pig femur, a cortical window was made in the diaphysis and bone cement was inserted. A total of 133 pig femurs were used and tumour resection was simulated with AR-assisted resection (164 resection in 82 femurs, half by an orthropaedic oncology expert and half by an orthopaedic resident) and resection with the conventional method (82 resection in 41 femurs). In the conventional group, resection was performed after measuring the distance from the edge of the condyle to the expected resection margin with a ruler as per routine clinical practice. Results. The mean error of 164 resections in 82 femurs in the AR group was 1.71 mm (0 to 6). The mean error of 82 resections in 41 femurs in the conventional resection group was 2.64 mm (0 to 11) (p < 0.05, one-way analysis of variance). The probabilities of a surgeon obtaining a 10 mm surgical margin with a 3 mm tolerance were 90.2% in AR-assisted resections, and 70.7% in conventional resections. Conclusion. We demonstrated that the accuracy of tumour resection was satisfactory with the help of the AR navigation system, with the tumour shown as a virtual template. In addition, this concept made the navigation system simple and available without additional cost or time. Cite this article: H. S. Cho, Y. K. Park, S. Gupta, C. Yoon, I. Han, H-S. Kim, H. Choi, J. Hong. Augmented reality in bone tumour resection: An experimental study. Bone Joint Res 2017;6:137–143


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_2 | Pages 63 - 63
10 Feb 2023
Lourens E Kurmis A Holder C de Steiger RN
Full Access

Total hip arthroplasty (THA) is an effective treatment for symptomatic hip osteoarthritis (OA). Computer-navigation technologies in total knee arthroplasty show evidence-supported survivorship advantages and are used widely. The aim of this study was to determine the revision outcome of hip commercially available navigation technologies. Data from the Australian Orthopaedic Association National Joint Replacement Registry from January 2016 to December 2020 included all primary THA procedures performed for osteoarthritis (OA). Procedures using the Intellijoint HIP® navigation were identified and compared to procedures inserted using ‘other’ computer navigation systems and to all non-navigated procedures. The cumulative percent revision (CPR) was compared between the three groups using Kaplan-Meier estimates of survivorship and hazard ratios (HR) from Cox proportional hazards models, adjusted for age and gender. A prosthesis specific analysis was also performed. There were 1911 procedures that used the Intellijoint® system, 4081 used ‘other’ computer navigation, and 160,661 were non-navigated. The all-cause 2-year CPR rate for the Intellijoint HIP® system was 1.8% (95% CI 1.2, 2.6), compared to 2.2% (95% CI 1.8, 2.8) for other navigated and 2.2% (95% CI 2.1, 2.3) for non-navigated cases. A prosthesis specific analysis identified the Paragon/Acetabular Shell THAs combined with the Intellijoint HIP® system as having a higher (3.4%) rate of revision than non-navigated THAs (HR = 2.00 (1.01, 4.00), p=0.048). When this outlier combination was excluded, the Intellijoint® system group demonstrated a two-year CPR of 1.3%. There was no statistical difference in the CPR between the three groups before or after excluding Paragon/Acetabular Shell system. The preliminary data presented demonstrate no statistical difference in all cause revision rates when comparing the Intellijoint HIP® THA navigation system with ‘other’ navigation systems and ‘non-navigated’ approaches for primary THAs performed for OA. The current sample size remains too small to permit meaningful subgroup statistical comparisons


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_II | Pages 99 - 99
1 May 2011
Mueller M Belei P Strake M Kabir K Radermacher K Wirtz D
Full Access

Introduction: Femoral neck fractures are common and percutaneous insertion of three cannulated screws is an accepted method of surgical treatment. The accuracy of surgical performance is highly correlated with the cut-out percentages of the screws. The conventional technique relies heavily on fiuoroscopy and could lead to inappropriate implant placement. Further, multiple guidewire passes might prolong the operation time and weaken the cancellous bone. A computer-assisted planning and navigation system based on 2D-fiuoroscopy has been developed for guidewire insertion in order to perform insertion of a guidewire to perform screw insertion. The image acquisition process was supported by a radiation-saving procedure called “Zero-dose C-arm navigation”. The purpose of this experimental study was to compare this technique with conventional C-arm fiuoroscopy with respect to the number of fiuoroscopic images, the number of drilling attempts and operation time. We used two operative settings, with sawbones and with cadavers. For the sawbone study, we also compared the femoral neck and head perforation and the neck-width coverage (the relative area of the femoral neck held by screws). Methods: Three cannulated hip screws were inserted into 12 femoral sawbones simulating femoral neck fractures and into 6 cadaveric femurs guided by the computer-based navigation. We compared them to the conventional fiuoroscopic technique also using 12 femoral sawbones and 6 cadaveric femurs. Results: The computer-assisted technique significantly reduced the amount of intraoperative fiuoroscopy (sawbone study: P< 0.001; cadaver study: P< 0.001) and the number of guidewire passes (sawbone study: P< 0.05; cadaver study: P< 0.05) in the sawbone and the cadaver setting. Operation time was significantly longer (sawbone study: P< 0.001; cadaver study: P< 0.05) in the navigation assisted group also in both settings. In the sawbone study, there was no significant difference in the femoral neck and head perforation, whereas the relative neck area held by the screws was significantly (P< 0.05) larger than that in the conventional group. Discussion: The addition of computer-assisted planning and surgical guidance supported by “Zero-dose C-arm navigation” may be useful for the fixation of femoral neck fractures by cannulated screws as it reduces the amount of intraoperative fiuoroscopy, requires fewer drill tracks and achieves a better neck coverage. Further studies with the goal of reducing the operation time by improving the learning curve are indispensable before integrating this navigation system into the clinical workfiow


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_4 | Pages 84 - 84
1 Apr 2019
Saravanja D Roger G
Full Access

Image guided surgery (IGS), or “Navigation,” is now widely used in many areas of surgery including arthroplasty. However, the options for establishing, in real time, the veracity of the navigation information are limited. Manufacturers recommend registering with a “prominent anatomical feature” to confirm accurate navigation is being presented. In their fine print, they warrant the accuracy proximate to the navigation array attached to the body. In multi-level spine surgery where it is most sorely needed, this limits the warrants to the vertebra of reference array attachment. In arthroplasty surgery, the accuracy of the system can be erroneous through technical errors and a delay may occur prior to verification of such innacuracy. In response to this situation surgeons have taken to using K-wires, FaxMax screws and a variety of other “Fiducial Markers”, but these were not specifically designed for this purpose and in many ways are inadequate for the task of verification of navigation accuracy. We have developed a fiducial marker that is designed to address these unmet needs. The Precision Screw is clearly visible on imaging modalities and the central registration point is identifiable at any angle of viewing, with accuracy of fractions of a millimeter. It does not interfere with surgery, being low profile and securely fixed to bone. Finally, in use, it is secure in capturing the navigation probe so that the surgeon does not need to focus on keeping the probe located while reviewing the navigation data. We believe these features make this a useful and worthwhile addition to IGS


The Bone & Joint Journal
Vol. 97-B, Issue 2 | Pages 258 - 264
1 Feb 2015
Young PS Bell SW Mahendra A

We report our experience of using a computer navigation system to aid resection of malignant musculoskeletal tumours of the pelvis and limbs and, where appropriate, their subsequent reconstruction. We also highlight circumstances in which navigation should be used with caution. We resected a musculoskeletal tumour from 18 patients (15 male, three female, mean age of 30 years (13 to 75) using commercially available computer navigation software (Orthomap 3D) and assessed its impact on the accuracy of our surgery. Of nine pelvic tumours, three had a biological reconstruction with extracorporeal irradiation, four underwent endoprosthetic replacement (EPR) and two required no bony reconstruction. There were eight tumours of the bones of the limbs. Four diaphyseal tumours underwent biological reconstruction. Two patients with a sarcoma of the proximal femur and two with a sarcoma of the proximal humerus underwent extra-articular resection and, where appropriate, EPR. One soft-tissue sarcoma of the adductor compartment which involved the femur was resected and reconstructed using an EPR. Computer navigation was used to aid reconstruction in eight patients. Histological examination of the resected specimens revealed tumour-free margins in all patients. Post-operative radiographs and CT showed that the resection and reconstruction had been carried out as planned in all patients where navigation was used. In two patients, computer navigation had to be abandoned and the operation was completed under CT and radiological control. The use of computer navigation in musculoskeletal oncology allows accurate identification of the local anatomy and can define the extent of the tumour and proposed resection margins. Furthermore, it helps in reconstruction of limb length, rotation and overall alignment after resection of an appendicular tumour. . Cite this article: Bone Joint J 2015;97-B:258–64


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_8 | Pages 96 - 96
1 May 2019
Su E
Full Access

Acetabular implant position is important for the stability, function, and long-term wear properties of a total hip arthroplasty (THA). Prior studies of acetabular implant positioning have demonstrated a high percentage of outliers, even in experienced hip surgeons, when conventional instruments are used. Computer navigation is an attractive tool for use in (THA, as it has been shown to improve the precision of acetabular component placement and reduce the incidence of outliers. However, computer navigation with imageless, large-console systems is costly and often interrupts the surgeon's workflow, and thus, has not been widely adopted. Another method to improve acetabular component positioning during THA is the use of fluoroscopy with the direct anterior approach. Studies have demonstrated that the supine position of the patient during surgery facilitates the use of fluoroscopic guidance, thus improving acetabular component position. A handheld, accelerometer based navigation unit for use in total hip replacement has recently become available to assist the surgeon in positioning the acetabular component during anterior approach THA, potentially reducing the need for intraoperative fluoroscopic studies. We sought to compare the radiographic results of direct anterior THA performed with conventional instrumentation vs. handheld navigation to determine the accuracy of the navigation unit, and to see whether or not there was a reduction in the fluoroscopic time used during surgery. Furthermore, we timed the use of the navigation unit to see whether or not it required a substantial addition to surgical time. Our results demonstrate that a handheld navigation unit used during anterior approach THA had no difference with regard to acetabular cup positioning when compared to fluoroscopically assisted THA, but led to a reduction in the use of intraoperative fluoroscopy time


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_14 | Pages 9 - 9
1 Nov 2021
Farey J Chai Y Xu J Sadegpour A Jones DM Baker N Vigdorchik J Walter W
Full Access

Imageless computer navigation systems in total hip arthroplasty (THA) improve acetabular cup position, thereby reducing the risk of revision surgery for all causes as well as dislocation. We aimed to evaluate the registration accuracy of 3 alternate registration planes. A prospective, observational study was conducted with 45 THA in the supine position using two imageless navigation systems and 3 registration planes. Patient position was registered sequentially using an optical system (Stryker OrthoMap) and an inertial sensor-based system (Navbit Sprint) with 3 planes of reference: (Plane 1) an anatomical plane using the anterior superior iliac spines (ASISs) and the pubic symphysis; (Plane 2) a functional plane parallel to the line between the ASISs and the table plane; and, (Plane 3) a functional plane that was perpendicular to the gravity vector and aligned with the longitudinal axis of the patient. The 3 measurements of acetabular cup inclination and anteversion were compared with the measurements from postoperative computed tomography (CT) scans. For inclination, the mean absolute error was significantly lower for Plane 3 (1.80°) than for Plane 2 (2.74°), p = .038 and was lower for both functional planes than for the anatomical plane (3.75°), p < .001. For anteversion, the mean absolute error was significantly lower for Plane 3 (2.00°) than for Plane 2 (3.69°), p = .004 and was lower for both functional planes than for the anatomical plane (8.58°), p < .001. Patient registration using functional planes more accurately measured the acetabular cup position than registration using anatomic planes


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_10 | Pages 55 - 55
1 Jun 2018
Su E
Full Access

Acetabular implant position is important for the stability, function, and long-term wear properties of a total hip arthroplasty (THA). Prior studies of acetabular implant positioning have demonstrated a high percentage of outliers, even in experienced hip surgeons, when conventional instruments are used. Computer navigation is an attractive tool for use in THA, as it has been shown to improve the precision of acetabular component placement and reduce the incidence of outliers. However, computer navigation with imageless, large-console systems is costly and often interrupts the surgeon's workflow, and thus, has not been widely adopted. Another method to improve acetabular component positioning during THA is the use of fluoroscopy with the direct anterior approach. Studies have demonstrated that the supine position of the patient during surgery facilitates the use of fluoroscopic guidance, thus improving acetabular component position. A handheld, accelerometer-based navigation unit for use in total hip replacement has recently become available to assist the surgeon in positioning the acetabular component during anterior approach THA, potentially reducing the need for intra-operative fluoroscopic studies. We sought to compare the radiographic results of direct anterior THA performed with conventional instrumentation vs. handheld navigation to determine the accuracy of the navigation unit, and to see whether or not there was a reduction in the fluoroscopic time used during surgery. Furthermore, we timed the use of the navigation unit to see whether or not it required a substantial addition to surgical time. Our results demonstrate that a handheld navigation unit used during anterior approach THA had no difference with regard to acetabular cup positioning when compared to fluoroscopically assisted THA, but led to a reduction in the use of intra-operative fluoroscopy time


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_4 | Pages 40 - 40
1 Apr 2019
Vigdorchik J Cizmic Z Elbuluk A Jerabek SA Paprosky W Sculco PK Meere P Schwarzkopf R Mayman DJ
Full Access

Introduction. Computer-assisted hip navigation offers the potential for more accurate placement of hip components, which is important in avoiding dislocation, impingement, and edge-loading. The purpose of this study was to determine if the use of computer-assisted hip navigation reduced the rate of dislocation in patients undergoing revision THA. Methods and Materials. We retrospectively reviewed 72 patients who underwent computer-navigated revision THA [Fig. 1] between January 2015 and December 2016. Demographic variables, indication for revision, type of procedure, and postoperative complications were collected for all patients. Clinical follow-up was performed at 3 months, 1 year, and 2 years. Dislocations were defined as any episode that required closed or open reduction or a revision arthroplasty. Data are presented as percentages and was analyzed using appropriate comparative statistical tests (z-tests and independent samples t- tests). Results. All 72 patients (48% female; 52% male) were included in the final analysis [Fig. 2]. Mean age of patients undergoing revision THA was 70.4 ± 11.2 years. Mean BMI was 26.4 ± 5.2 kg/m. 2. The most common indications for revision THA were instability (31%), aseptic loosening (29%), osteolysis/eccentric wear (18%), infection (11%), and miscellaneous (11%). During revision procedure, polyethylene component was most commonly changed (46%), followed by femoral head (39%), and acetabular component (15%). At 3 months, 1 year, and final follow-up, there were no dislocations among all study patients (0%). Compared to preoperative dislocation values, there was a significant reduction in the rate of dislocation with the use of computer-assisted hip navigation (31% vs. 0%; p<0.05). Discussion. Our study demonstrates a significant reduction in the rate of dislocation following revision THA with the use of computer navigation. Although the cause of postoperative dislocation is often multifactorial, the use of computer-assisted surgery may help to curtail femoral and acetabular malalignment in revision THA


Orthopaedic Proceedings
Vol. 91-B, Issue SUPP_II | Pages 342 - 342
1 May 2009
Tang N Leung K
Full Access

Intra-operative 3-D fluoroscopy has limitations, including low resolution images, little soft tissue information and small working volume. Fusion of 3D data sets (MRI/ CT) had been developed in pre-operative planners. We employed the same principle and developed a new technique of navigation with fused images of pre-operative MRI/CT and intra-operative 3D fluoroscopy. Pre-op CT/MRI in DICOM was imported to the Stryker Leibinger Spine 3-D and segmentation of the intended bone performed. Patient tracker was mounted and 3-D fluoroscopy performed using Siemens ISO-C 3D. Fusion of CT/MRI with 3D fluoroscopy was performed using “surface matching image correlation” and this automatically registered the bone with MRI/CT. The fused images were then ready for 3D navigation procedures. Nine patients were included in the series. There were eight fracture cases and seven performed with fused CT and 3-D fluoroscopy (two PCL avulsion fractures, two tibial plateau fractures, one femoral condyle fracture and three pelvic-acetabular fractures). Total of twenty-three screws had been inserted without complication. One tibial plateau fracture fixation and one core decompression for avascular necrosis of femoral head were performed with fused MRI to 3D fluoroscopy. In conclusion, intra-operative 3-D navigated procedures with fused pre-operative MRI/CT and intra-operative 3-D fluoroscopy were all successful with (1) extended working volume (2) higher resolution images (3) more soft tissue information. We foresee more applications of this new technique in other areas of computer aided surgery


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_4 | Pages 99 - 99
1 Apr 2019
Wahrburg J Gieseler O Roth H
Full Access

Total hip replacement procedures are among the most frequent surgical interventions in all industrialized countries. Although it is a routine operationliterature reports that important parameters regarding for example cup orientation and leg length discrepancy often turn out to be not satisfying after surgery. This paper presents a novel concept to improve the reproducibility and accuracy for implantation of cup and stem prosthesis at exactly the desired locations. Existing computer- based commercial products either offer software solutions for just pre-operative planning, or imageless navigation systems that are only used during surgery in the operating theatre. The innovation of our approach is based on an integrated computer-assisted solution that combines pre-operative planning and intra-operative navigation to support THR procedures. The software for pre-operative planning can process both, 3D CT images and standard 2D x-ray images. A custom-built navigation system using optical 3D localizing technology has been developed to transfer planning results to the OR. The main objective of our approach is to implant the artificial joint in a way to restore the natural anatomy of the joint before surgery as close as possible, or with exactly planned modifications. In particular, cup inclination, cumulative anteversion of cup and stem, CCD angle and lateral offset, centre of rotation, leg length discrepancy, and joint range of motion are considered. It is not necessary to determine numerical values for all of these parameters because our approach uses a unique procedure to record the natural anatomical situation by combining pre-operative planning and intra-operative navigation, and subsequently supports implantation of the prosthesis components by surgical navigation in order to restore this situation. In case planar 2D x-ray images are used for pre-operative planning accurate scaling of these images is a prerequisite for exact determination of relevant parameters. The patient-specific scaling factor depends on the distance of the hip joint rotation centre from the x-ray detector or film. We have designed a low-cost localization system to be mounted close to the x-ray apparatus. It localizes the 3D position of the rotation centre by small motions of the leg and eliminates uncertainties of conventional methods that are caused by improper positioning of a calibration body. Easy and robust setup and application have been key objectives for the development of our custom-built navigation system. Acquisition of intraoperative parameters for example includes the determination of the acetabular centre axis by localizing selected landmarks at the acetabular rim. Intra-operative parameters are combined with pre-operative parameters without needing sophisticated matching procedures with the pre-operative images. A preliminary surgical workflow that will be detailed in the conference presentation has been designed for evaluation of the concept using sawbones models. Based on the promising results of our laboratory tests we have started to prepare first clinical experiments in close cooperation with surgeons


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_1 | Pages 40 - 40
1 Feb 2020
Tarallo L Porcellini G Giorgini A Pellegrini A Catani F
Full Access

Introduction. Total shoulder replacement is a successful treatment for gleno-humeral osteoarthritis. However, components loosening and painful prostheses, related to components wrong positioning, are still a problem for those patients who underwent this kind of surgery. CT-based intraoperative navigation system is a suitable option to improve accuracy and precision of the implants as previously described in literature for others district. Method. Eleven reverse shoulder prostheses were performed at Modena Polyclinic from October 2018 to April 2019 using GPS CT-based intraoperative navigation system (Exactech, Gainsville, Florida). In the preoperative planning, Walch classification was used to assess glenoid type. The choice of inclination of the glenoid component, the screw length, as well as the inclination of the reamer was study and recorded using specific software using the CT scan of shoulder of each patient (Fig.1, Fig.2). Intraoperative and perioperative complications were recorded. Three patients were male, eight were female. Mean age was 72 years old (range 58=84). Three glenoid were type B2, six cases were B1, two case were type C1. Results. In all cases treated by reverse shoulder prostheses we had obtain good functional results at preliminary follow up. Eight degree posterior augment was used in seven case. Planned version was 0° in eight case, an anti-version of 3° was planned in the other three cases. Final reaming was as preoperatively planned in all cases except one. Mean surgical time was 71 minutes (range 51–82). One case of coracoid rupture has been reported. In all cases the system worked in proper manner without failures, no case of infection was reported. Discussion. It is well known as the more accurate placement of the glenoid led to enhanced long-term survivorship of the implant and decrease complication rates in RSTA. Our first experience with GPS navigation system has been satisfied. Good components’ positioning has been reached in all cases, without deviation from the preoperative planning. Pre-operative preparation using software has been always respected except in one case in which we decided to ream 1mm less to avoid excessive bone loss. In 3 case we decide to increase glenoid anti-version to allow a good cage containment in the scapula. No failure of the system has been recorded, with a little increase in the surgical time respect to traditional surgeries performed in our institute. The first case performed reported coracoid fracture, probably due to lack of experience in coracoid tracker positioning. It is very important to set the surgical theatre and the position of the patient in order to make the coracoid tracker visible for the computer. Screw positioning and length is decisively improved with GPS system compared with traditional implant. The most important advantage is to avoid the malposition of the glenoid component, solving problems like loosening or restriction in shoulder range of motion. We believe that a final cross check between preoperative planning and final control of the prostheses implanted, should be used in the future, but by now the GPS navigation system is a useful way to improve our surgery, especially in difficult cases. For any figures or tables, please contact the authors directly


The Bone & Joint Journal
Vol. 95-B, Issue 4 | Pages 493 - 497
1 Apr 2013
Hino K Ishimaru M Iseki Y Watanabe S Onishi Y Miura H

There are several methods for evaluating stability of the joint during total knee replacement (TKR). Activities of daily living demand mechanical loading to the knee joint, not only in full extension, but also in mid-flexion. The purpose of this study was to compare the varus-valgus stability throughout flexion in knees treated with either cruciate-retaining or posterior-stabilised TKR, using an intra-operative navigation technique. A total of 34 knees underwent TKR with computer navigation, during which the investigator applied a maximum varus-valgus stress to the knee while steadily moving the leg from full extension to flexion both before and after prosthetic implantation. The femorotibial angle was measured simultaneously by the navigation system at every 10° throughout the range of movement. It was found that posterior-stabilised knees had more varus-valgus laxity than cruciate-retaining knees at all angles examined, and the differences were statistically significant at 10° (p = 0.0093), 20° (p = 0.0098) and 30° of flexion (p = 0.0252). Cite this article: Bone Joint J 2013;95-B:493–7


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 2 | Pages 163 - 167
1 Feb 2006
Kalteis T Handel M Bäthis H Perlick L Tingart M Grifka J

In a prospective randomised clinical study acetabular components were implanted either freehand (n = 30) or using CT-based (n = 30) or imageless navigation (n = 30). The position of the component was determined post-operatively on CT scans of the pelvis. Following conventional freehand placement of the acetabular component, only 14 of the 30 were within the safe zone as defined by Lewinnek et al (40° inclination . sd. 10°; 15° anteversion . sd. 10°). After computer-assisted navigation 25 of 30 acetabular components (CT-based) and 28 of 30 components (imageless) were positioned within this limit (overall p < 0.001). No significant differences were observed between CT-based and imageless navigation (p = 0.23); both showed a significant reduction in variation of the position of the acetabular component compared with conventional freehand arthroplasty (p < 0.001). The duration of the operation was increased by eight minutes with imageless and by 17 minutes with CT-based navigation. Imageless navigation proved as reliable as that using CT in positioning the acetabular component


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_15 | Pages 111 - 111
1 Aug 2017
Su E
Full Access

Acetabular implant position is important for the stability, function, and long-term wear properties of a total hip arthroplasty (THA). Prior studies of acetabular implant positioning have demonstrated a high percentage of outliers, even for experienced hip surgeons, when conventional instruments are used. Computer navigation is an attractive tool for use in THA, as it has been shown to improve the precision of acetabular component placement and reduce the incidence of outliers. However, computer navigation with imageless, large-console systems is costly and often interrupts the surgeon's workflow, and thus has not been widely adopted. Another method to improve acetabular component positioning during THA is the use of fluoroscopy with the direct anterior approach. Studies have demonstrated that the supine position of the patient during surgery facilitates the use of fluoroscopic guidance, thus improving acetabular component position. A handheld, accelerometer based navigation unit for use in total hip replacement has recently become available to assist the surgeon in positioning the acetabular component during anterior approach THA, potentially reducing the need for intra-operative fluoroscopic studies. We sought to compare the radiographic results of direct anterior THA performed with conventional instrumentation vs. handheld navigation to determine the accuracy of the navigation unit, and to see whether or not there was a reduction in the fluoroscopic time used during surgery. Furthermore, we timed the use of the navigation unit to see whether or not it required a substantial addition to surgical time. Our results demonstrate that a handheld navigation unit used during anterior approach THA had no difference with regard to acetabular cup positioning when compared to fluoroscopically assisted THA, but led to a reduction in the use of intra-operative fluoroscopy time


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 5 | Pages 601 - 605
1 May 2006
Pitto RP Graydon AJ Bradley L Malak SF Walker CG Anderson IA

The object of this study was to develop a method to assess the accuracy of an image-free total knee replacement navigation system in legs with normal or abnormal mechanical axes. A phantom leg was constructed with simulated hip and knee joints and provided a means to locate the centre of the ankle joint. Additional joints located at the midshaft of the tibia and femur allowed deformation in the flexion/extension, varus/valgus and rotational planes. Using a digital caliper unit to measure the coordinates precisely, a software program was developed to convert these local coordinates into a determination of actual leg alignment. At specific points in the procedure, information was compared between the digital caliper measurements and the image-free navigation system. Repeated serial measurements were undertaken. In the setting of normal alignment the mean error of the system was within 0.5°. In the setting of abnormal plane alignment in both the femur and the tibia, the error was within 1°. This is the first study designed to assess the accuracy of a clinically-validated navigation system. It demonstrates in vitro accuracy of the image-free navigation system in both normal and abnormal leg alignment settings


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_9 | Pages 8 - 8
1 Jun 2021
Giorgini A Tarallo L Porcellini G Micheloni G
Full Access

Introduction. Reverse shoulder Arthroplasty is a successful treatment for gleno-humeral osteoarthritis. However, components loosening and painful prostheses, related to components wrong positioning, are still a problem for those patients who underwent this kind of surgery. Several new technology has been developed the improve the implant positioning. CT-based intraoperative navigation system is a suitable technology that allow the surgeon to prepare the implant site exactly as planned with preoperative software. Method. Thirty reverse shoulder prostheses were performed at Modena Polyclinic using GPS CT-based intraoperative navigation system (Exactech, Gainsville, Florida). Walch classification was used to assess glenoid type. Planned version and inclination of the glenoid component, planned seating, final version and inclination of the reamer were recorded. Intraoperative and perioperative complication were recorded. Planned positioning was conducted aiming to the maximum seating, avoiding retroversion >10° and superior inclination. Results. Eight patients were male, 22 were female. Mean age was 75 years old (range 58–87). 4 glenoid were type B3, four were B2, 10 cases were B1, 12 case were A1/A2. Posterior or superior augment was used in 15 cases. Mean planned seating was 93%. Mean preoperative version was -7.5±6.9°; Mean planned version was -2±2.8°; Mean intraoperative measured version was -1.9±2.8°; no statistical difference was found between planned and intraoperative version (p=0.16). Mean preoperative inclination was 1.8±6.°; Mean planned inclination was -2.2±2.4°; Mean intraoperative measured inclination was -2.1.9±2.3°; no statistical difference was found between planned and intraoperative version or inclination (respectively p=0.16 and p=0.32). Mean surgical time was 71 minute (range 51–82). Three cases of coracoid ruptures were reported, 1 failure of the system occurred. Discussion. GPS navigation system allows the surgeon to prepare the implant site as planned on Preoperative software in Reverse shoulder arthroplasty, with no statistical difference between planned orientation and intraoperative measured orientation. That means that even in the most difficult cases the surgeon is able to find a good positioning (93% seating)and to replicate it in the operative room. Only one failure of the system occurred, because too much time was passed between CT scan and surgery (9 months). Three coracoid fractures occurred in the first 10 cases: these could be addressed to a lack of confidence with the double lateralization of this prosthesis which increase tensioning on the coracoid and a lack of confidence in tracker positioning, which should be made as proximal as it is possible. Finally, the system needs several improvements to be considered a breakthrough technology, such as humeral component positioning and final control of the implant, but by now is a useful way to improve our surgery, especially in difficult cases


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_12 | Pages 57 - 57
23 Jun 2023
Konishi T Sato T Motomura G Hamai S Kawahara S Hara D Utsunomiya T Nakashima Y
Full Access

Accurate cup placement in total hip arthroplasty (THA) for the patients with developmental dysplasia of the hip (DDH) is one of the challenges due to distinctive bone deformity. Robotic-arm assisted system have been developed to improve the accuracy of implant placement. This study aimed to compare the accuracy of robotic-arm assisted (Robo-THA), CT-based navigated (Navi-THA), and manual (M-THA) cup position and orientation in THA for DDH. A total of 285 patients (335 hips) including 202 M-THAs, 45 Navi-THAs, and 88 Robo-THA were analyzed. The choice of procedure followed the patient's preferences. Horizontal and vertical center of rotation (HCOR and VCOR) were measured for cup position, and radiographic inclination (RI) and anteversion (RA) were measured for cup orientation. The propensity score-matching was performed among three groups to compare the absolute error from the preoperative target position and angle. Navi-THA showed significantly smaller absolute errors than M-THA in RI (3.6° and 5.4°) and RA (3.8° and 6.0°), however, there were no significant differences between them in HCOR (2.5 mm and 3.0 mm) or VCOR (2.2 mm and 2.6 mm). In contrast, Robo-THA showed significantly smaller absolute errors of cup position than both M-THA and Navi-THA (HCOR: 1.7 mm and 2.9 mm, vs. M-THA, 1.6 mm and 2.5 mm vs. Navi-THA, VCOR:1.7 mm and 2.4 mm, vs. M-THA, 1.4 mm and 2.2 mm vs. Navi-THA). Robo-THA also showed significantly smaller absolute errors of cup orientation than both M-THA and Navi-THA (RI: 1.4° and 5.7°, vs. M-THA, 1.5° and 3.6°, vs. Navi-THA, RA: 1.9° and 5.8° vs. M-THA, 2.1° and 3.8° vs. Navi-THA). Robotic-arm assisted system showed more accurate cup position and orientation compared to manual and CT-based navigation in THA for DDH. CT-based navigation increased the accuracy of cup orientation compared to manual procedures, but not cup position


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_1 | Pages 93 - 93
1 Feb 2020
Cipparone N Robinson M Chen J Muir J Shah R
Full Access

Acetabular cup positioning remains a real challenge and component malpositioning after total hip arthroplasty (THA) can lead to increased rates of dislocation and wear. It is a common cause for revision THA. A novel 3D imageless mini-optical navigation system was used during THA to provide accurate, intraoperative, real-time, and non-fluoroscopic data including component positioning to the surgeon. This retrospective comparative single surgeon and single approach study examined acetabular component positioning between traditional mini-posterolateral THA and mini-posterolateral THA using the 3D mini-optical navigation system. A retrospective chart review was conducted of 157 consecutive (78 3D mini-optical navigation and 79 traditional non-navigation methods) THAs performed by the senior author using a mini-posterolateral approach at an ambulatory surgery center and hospital setting. Two independent reviewers analyzed postoperative radiographs in a standardized fashion to measure acetabular component positioning. Demographic, clinical, surgical, and radiographic data were analyzed. These groups were found to have no statistical difference in age, gender, and BMI (Table I). There was no difference between groups in acetabular components in the Lewinnek safe zone, 31.2% vs 26.6% (p = 0.53). Cup anteversion within the safe zone did not differ, 35.1% vs 40.5% (p = 0.48); while cup inclination within the safe zone differed, with more in the navigation group, 77.9% vs 51.9% (p < 0.01). Change in leg length was significantly different with the navigation group's leg length at 1.9 ± 6.3, less than the traditional at 5.4 ± 7.0 (p < 0.01). There was no difference in mean change in offset between groups (4.5 ± 5.9 vs 6.2 ± 7.9, p = 0.12); navigation, traditional) (Table II). The 3D mini-optical navigation group did have significantly longer operative time (98.4 ± 17.5 vs 89.3 ± 15.5 p < 0.01). Use of the novel 3D Mini-optical Navigation System significantly improved cup inclination compared to traditional methods while increasing operative time. For any figures or tables, please contact the authors directly


Bone & Joint Open
Vol. 2, Issue 3 | Pages 191 - 197
1 Mar 2021
Kazarian GS Barrack RL Barrack TN Lawrie CM Nunley RM

Aims. The purpose of this study was to compare the radiological outcomes of manual versus robotic-assisted medial unicompartmental knee arthroplasty (UKA). Methods. Postoperative radiological outcomes from 86 consecutive robotic-assisted UKAs (RAUKA group) from a single academic centre were retrospectively reviewed and compared to 253 manual UKAs (MUKA group) drawn from a prior study at our institution. Femoral coronal and sagittal angles (FCA, FSA), tibial coronal and sagittal angles (TCA, TSA), and implant overhang were radiologically measured to identify outliers. Results. When assessing the accuracy of RAUKAs, 91.6% of all alignment measurements and 99.2% of all overhang measurements were within the target range. All alignment and overhang targets were simultaneously met in 68.6% of RAUKAs. When comparing radiological outcomes between the RAUKA and MUKA groups, statistically significant differences were identified for combined outliers in FCA (2.3% vs 12.6%; p = 0.006), FSA (17.4% vs 50.2%; p < 0.001), TCA (5.8% vs 41.5%; p < 0.001), and TSA (8.1% vs 18.6%; p = 0.023), as well as anterior (0.0% vs 4.7%; p = 0.042), posterior (1.2% vs 13.4%; p = 0.001), and medial (1.2% vs 14.2%; p < 0.001) overhang outliers. Conclusion. Robotic system navigation decreases alignment and overhang outliers compared to manual UKA. Given the association between component placement errors and revision in UKA, this strong significant improvement in accuracy may improve implant survival. Level of Evidence: III. Cite this article: Bone Jt Open 2021;2-3:191–197


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_16 | Pages 23 - 23
1 Oct 2014
Taki N Mitsugi N Mochida Y Aratake M Ota H Shinohara K Saito T
Full Access

Imageless navigation is useful in acetabular cup orientation during total hip arthroplasty (THA). There is a limitation of accuracy in the imageless navigation system because of the registration method, that is, to palpate bony landmarks over the skin. To improve this limitation, ultrasound-based navigation was introduced for more precise registration of bony landmarks. We evaluated the accuracy of placement of the implant, which was measured by CT in 66 patients. 22 patients underwent THA with imageless navigation, and 44 patients underwent THA with ultrasound-based navigation. The accuracy was evaluated by comparison of the navigation values obtained during surgery with the CT measured values. For the 44 patients with ultrasound-based navigation system, the mean CIA was 39.6+4.1 degrees (mean+SD) and the CAA was 18.5+6.1 degrees with CT evaluation. Ultrasound-based navigation showed 39.0+3.2 degrees in CIA and 18.8+5.9 degrees in CAA during surgery. The mean absolute difference in cup inclination angle (CIA) between ultrasound-based navigation and CT was 2.4+2.1 degrees (range 0.1–9.2 degrees). The mean absolute difference in cup anteversion angle (CAA) between navigation and CT was 2.2+2.7 degrees (0.04–12.2 degrees). The rasp ante-torsion angle was 28.6+10.0 degrees in the ultrasound-based navigation system. The mean SAA was 28.8+9.3 degrees in CT. Strong correlation was found between the rasp ante-torsion angle and SAA (r=0.858). The mean absolute difference between the rasp ante-torsion angle and SAA was 4.3+3.6 degrees (0.2-17.2 degrees). For the 22 patients with imageless navigation system, the mean absolute difference between imageless navigation and CT in CIA, CAA, and SAA were 2.5+1.8 degrees (0.1–5.8 degrees), 5.4+3.8 degrees (0.1–17.2 degrees), and 5.2+3.0 degrees (1.1-12 degrees) respectively. The thickness of subcutaneous tissue at the pubic symphysis was correlated to the difference in CAA between the imageless navigation and CT (r=0.456). Ultrasound-based navigation showed higher accuracy in CAA compare to imageless navigation. Moreover, ultrasound-based navigation showed almost the same accuracy of placement of the implant compare to the reported accuracy with CT-based navigation. Ultrasound-based navigation system improved the limitation of accuracy in the imageless navigation system


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_2 | Pages 103 - 103
1 Feb 2020
Herrero C Lavery J Anoushiravani A Davidovitch R
Full Access

We investigated whether a novel, real-time fluoroscopy based navigation system optimized component positioning and leg length in fluoroscopically aided Direct Anterior Approach Total Hip Arthroplasty (DAA-THA). We retrospectively reviewed 75 fluoroscopically assisted DAA-THA performed by a single surgeon: 37 procedures used the software intraoperatively to overlay anteversion, inclination, and leg length information over the existing fluoroscopic radiograph with the aim of enhancing component positioning. The control group consisted of 38 procedures from the single surgeon's patient pool who had undergone non-navigated fluoroscopic assisted DAA-THA one month prior to the system's trial. We used the software to compute each data point on an immediate post operative AP radiograph to replicate the intra operative measurement process. Our results demonstrate that the navigation group measurements were significantly closer to the target numbers with less variation. The mean values were significantly closer to target values anteversion (control: 14°, navigated: 19.1°), inclination (control: 37.7°, navigated: 40.8°) and leg length discrepancy (control: 4.7mm, navigated: 0.1mm). The mean difference from target value were also statistically significant: for anteversion (control: −6.0°, navigated: −0.9°), inclination (control: −2.3°, navigated: 0.8°) and leg length discrepancy (control: 2.7°, navigated: −1.9°). In addition, surgical time was shorter in the navigation group (75.7 vs. 74 minutes; p=0.001). The p values were all statistically significant (anteversion 0.0001, inclination 0.0019, LLD < 0.001 and surgical time 0.001). The real-time feedback and calculations provided by the navigation software provided a reproducible precision for component positioning and leg length measurement during DAA-THA. For any figures or tables, please contact authors directly


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_5 | Pages 76 - 76
1 Apr 2018
Su E Khan I Kiser C
Full Access

INTRODUCTION. Traditionally, acetabular component insertion in direct anterior approach (DAA) total hip arthroplasty (THA) has been performed using fluoroscopic guidance. Handheld navigation systems can be used to address issues of alignment, cup placement and accuracy of measurements. Previous navigation systems have been used successfully in total knee arthroplasty (TKA) and has now been introduced in THA. We investigated the use of a new accelerometer-based, handheld navigation system during DAA THA to compare it to traditional means. This study aims to determine accuracy of acetabular cup placement as well as fluoroscopy times between two groups of patients. METHODS. Data was prospectively collected for a group of consecutive DAA THA procedures using a handheld navigation system (n=45) by a single surgeon. This was compared to data retrospectively collected for a group that underwent the same procedure without use of the navigation system(n=50). The time for use of the navigation system, including insertion of pins/registration, guiding cup position, and removal of pins, was recorded intraoperatively. Postoperative anteroposterior and cross-table lateral radiographs were used to measure acetabular inclination and anteversion angles. Targeted angles for all cases were 40° ±5 for inclination and 20° ±5 for anteversion. Intraoperative fluoroscopy exposure times were obtained from post-anesthesia care unit radiographs. RESULTS. Mean time of pin insertion/registration, cup positioning and removal was 180.5 seconds, 127.7 seconds and 26 seconds, giving a mean total time of 5.6 minutes. There were no significant differences in mean postoperative acetabular inclination angles between the navigation group as compared to the non-navigation group (39.8° vs 40.6°) (p = .2). There were no significant differences in mean postoperative acetabular anteversion angles between the navigation group as compared to the non-navigation group (24.3° vs 23.7°) (p=.5). Mean intraoperative fluoroscopy exposure times were significantly lower in the navigation group as compared to the non-navigation group (12.6 vs 22.2 seconds) (p<.0001). CONCLUSION. The findings demonstrated that a new handheld navigation system required minimal increase in operative time and was as accurate for cup positioning as fluoroscopically assisted DAA THA. Furthermore, there was a 45% reduction in fluoroscopy exposure time. Reduction in fluoroscopy time will lower radiation exposure for the surgeon and patients


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 4 | Pages 455 - 460
1 Apr 2007
Sugano N Nishii T Miki H Yoshikawa H Sato Y Tamura S

We have developed a CT-based navigation system using infrared light-emitting diode markers and an optical camera. We used this system to perform cementless total hip replacement using a ceramic-on-ceramic bearing couple in 53 patients (60 hips) between 1998 and 2001. We reviewed 52 patients (59 hips) at a mean of six years (5 to 8) postoperatively. The mid-term results of total hip replacement using navigation were compared with those of 91 patients (111 hips) who underwent this procedure using the same implants, during the same period, without navigation. There were no significant differences in age, gender, diagnosis, height, weight, body mass index, or pre-operative clinical score between the two groups. The operation time was significantly longer where navigation was used, but there was no significant difference in blood loss or navigation-related complications. With navigation, the acetabular components were placed within the safe zone defined by Lewinnek, while without, 31 of the 111 components were placed outside this zone. There was no significant difference in the Merle d’Aubigne and Postel hip score at the final follow-up. However, hips treated without navigation had a higher rate of dislocation. Revision was performed in two cases undertaken without navigation, one for aseptic acetabular loosening and one for fracture of a ceramic liner, both of which showed evidence of neck impingement on the liner. A further five cases undertaken without navigation showed erosion of the posterior aspect of the neck of the femoral component on the lateral radiographs. These seven impingement-related mechanical problems correlated with malorientation of the acetabular component. There were no such mechanical problems in the navigated group. We conclude that CT-based navigation increased the precision of orientation of the acetabular component and control of limb length in total hip replacement, without navigation-related complications. It also reduced the rate of dislocation and mechanical problems related to impingement


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_13 | Pages 119 - 119
1 Nov 2021
Facchini A Troiano E Saviori M Meglio MD Ghezzi R Mondanelli N Giannotti S
Full Access

Introduction and Objective. The aim of this study was to evaluate whether CT-based pre-operative planning, integrated with intra-operative navigation could improve glenoid baseplate fixation and positioning by increasing screw length, reducing number of screws required to obtain fixation and increasing the use of augmented baseplate to gain the desired positioning. Reverse total shoulder arthroplasty (RSA) successfully restores shoulder function in different conditions. Glenoid baseplate fixation and positioning seem to be the most important factors influencing RSA survival. When scapular anatomy is distorted (primitive or secondary), optimal baseplate positioning and secure screw purchase can be challenging. Materials and Methods. Twenty patients who underwent navigated RSA (oct 2018 and feb 2019) were compared retrospectively with twenty patients operated on with a conventional technique. All the procedures were performed by the same surgeon, using the same implant in cases of eccentric osteoarthritis or complete cuff tear. Exclusion criteria were: other diagnosis as proximal humeral fractures, post-traumatic OA previously treated operatively with hardware retention, revision shoulder arthroplasty. Results. The NAV procedure required mean 11 (range 7–16) minutes more to performed than the conventional procedure. Mean screw length was significantly longer in the navigation group (35.5+4.4 mm vs 29.9+3.6 mm; p . .001). Significant higher rate of optimal fixation using 2 screws only (17 vs 3 cases, p . .019) and higher rate of augmented baseplate usage (13 vs 4 cases, p . .009) was also present in the navigation group. Signficant difference there is all in function outcomes, DASH score is 15.7 vs 29.4 and constant scale 78.1 vs 69.8. Conclusions. The glenoid component positioning in RSA is crucial to prevent failure, loosening and biomechanical mismatch, coverage by the baseplate of the glenoid surface, version, inclination and offset are all essential for implant survival. This study showed how useful 3D CT-based planning helps in identifying the best position of the metaglena and the usefulness of receiving directly in the operation theater real-time feedback on the change in position. This study shows promising results, suggesting that improved baseplate and screw positioning and fixation is possible when computer-assisted implantation is used in RSA comparing to a conventional procedure


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XL | Pages 80 - 80
1 Sep 2012
Jenny J
Full Access

Surgical navigation in joint replacement has been developed for more than 10 years. After the initial enthusiastic period, it appears that few surgeons have included this technology into their routine practice. The reasons for this backflow are lack of evidence of any clinical superiority for navigation implanted prostheses, higher costs and longer operative time. However, navigation systems have evolved, and might still belong to the future of joint replacement. Although most studies did not observe clinically relevant differences between navigated and conventional joint replacement, some registry studies identified significant advantages in favor of navigation: less blood loss, less early revision, subtle but relevant functional improvement… If TKR may be more forgiving, there is a trend to use less invasive implants (UKR), which are technically more demanding and may benefit from navigation. Ligamentous balancing may be more accurate and more reproducible with the help of navigation, and in that way patient specific templates may benefit from navigation. New techniques (short stem hip implants, hip resurfacing) have a relevant learning curve which may be fastened with navigation support. Another key point may be the individual joint reconstruction: anatomy is different from one patient to the other, and navigation may help detecting these subtle differences to adapt a more physiological joint reconstruction, instead reconstructing all joints on the same model. New navigation systems now available are designed in a more user-friendly style, with more straightforward workflow, and may be adapted to every surgeon's need. Finally, navigation system may act as documentation and quality control system for health care providers, as well as a very powerful research tool for scientists and manufacturers


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_18 | Pages 19 - 19
1 Dec 2014
Khan H Goudie S Deep K
Full Access

Introduction:. Restoration of normal hip biomechanics is vital for success of total hip arthroplasty (THA). This requires accurate placement of implants and restoration of limb length and offset. The purpose of this study was to assess the accuracy of computer navigation system in predicting cup placement and restoring limb length and offset. Material and Methods:. An analysis of 259 consecutive patients who had THA performed with imageless computer navigation system was carried out. Acetabular cup abduction and anteversion, medialisation or lateralisation of offset and limb length change were compared between navigation measurements and follow-up radiographs. Sensitivity, specificity, accuracy and PPV were calculated to assess navigation for cup orientation and student t-test used for evaluation of offset and limb length change. Results:. Mean cup abduction and anteversion was 40.35° (SD, 5.81) and 18.46° (SD, 6.79) in postop radiographs compared to 41° (SD, 5.03) and 14.76°(SD, 6.11) for navigation measurements. Intraoperative navigation measurements had high PPV and specificity for determining cup abduction and anteversion (PPV >95%, specificity >90%). Accuracy for determining cup abduction was 96.13% compared to 72.2% for cup anteversion. Change in limb length and offset was mean 6.46 mm (SD, 5.68) and −1.07 mm (SD, 5.75) on radiograph evaluation and 5.41 mm (SD, 5.11) and −2.24 mm (SD, 5.87) from navigation measurements respectively, the difference being not significant in both (p value >0.2). Radiograph and navigation had a mean difference of 1.01 mm (SD, 2.83) for offset measurements and a mean difference of 1.05 mm (SD, 4.37) for postop limb length assessment. Discussion:. To conclude, navigation can serve as an excellent tool for appropriate placement of implants and restoring limb length and offset in THA


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_34 | Pages 191 - 191
1 Dec 2013
Lavernia C Iacobelli D Villa J
Full Access

INTRODUCTION. Computer navigation has been shown to decrease the variance of component positioning in primary THR. The cost of a navigation system in the U.S. however can exceed $200,000 in capital costs and $300–850 a case for disposables. Our objective was to assess the cost-utility of a hip navigation system. METHODS. A review of the literature on costs and times for primary THR was done. Consecutive THR were done with an infrared navigation system. Total surgical time from incision to final skin closure and intra-operative time associated with the navigation process were recorded. Professional fees and the costs of revision surgery were estimated. RESULTS. The average total surgical time for THR was 96.6 minutes ± 8.4 SE for the navigated cohort and 77 minutes ± 1.3 SE for the THR without navigation. Setup of patient trackers and surgical landmarks registration averaged 14.4 minutes for the navigated surgery. The total additional costs (increase in OR time, anesthesia professional fees and the disposable expenses) were $813 for a primary THR using navigation. Reduction by 50% in dislocation and revision rates will yield savings where the system will pay for itself in 5 years doing only 30 cases per year. DISCUSSION AND CONCLUSION. Assuming 30% of all primary cases are performed with navigation, the incremental cost to the health care system would exceed $300 million a year. Depending on the model and assumptions used to calculate reduction in revisions and dislocations this system could be cost-effective for society if used in high-volume centers


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 10 | Pages 1414 - 1420
1 Oct 2012
Cho HS Oh JH Han I Kim H

We evaluated the oncological and functional outcome of 18 patients, whose malignant bone tumours were excised with the assistance of navigation, and who were followed up for more than three years. There were 11 men and seven women, with a mean age of 31.8 years (10 to 57). There were ten operations on the pelvic ring and eight joint-preserving limb salvage procedures. The resection margins were free of tumour in all specimens. The tumours, which were stage IIB in all patients, included osteosarcoma, high-grade chondrosarcoma, Ewing’s sarcoma, malignant fibrous histiocytoma of bone, and adamantinoma. The overall three-year survival rate of the 18 patients was 88.9% (95% confidence interval (CI) 75.4 to 100). The three-year survival rate of the patients with pelvic malignancy was 80.0% (95% CI 55.3 to 100), and of the patients with metaphyseal malignancy was 100%. The event-free survival was 66.7% (95% CI 44.9 to 88.5). Local recurrence occurred in two patients, both of whom had a pelvic malignancy. The mean Musculoskeletal Tumor Society functional score was 26.9 points at a mean follow-up of 48.2 months (22 to 79). We suggest that navigation can be helpful during surgery for musculoskeletal tumours; it can maximise the accuracy of resection and minimise the unnecessary sacrifice of normal tissue by providing precise intra-operative three-dimensional radiological information