header advert
Results 1 - 5 of 5
Results per page:
Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_1 | Pages 51 - 51
1 Feb 2021
Smith L Cates H Freeman M Nachtrab J Komistek R
Full Access

Background

While posterior cruciate retaining (PCR) implants are a more common total knee arthroplasty (TKA) design, newer bi-cruciate retaining (BCR) TKAs are now being considered as an option for many patients, especially those that are younger. While PCR TKAs remove the ACL, the BCR TKA designs keep both cruciate ligaments intact, as it is believed that the resection of the ACL greatly affects the overall kinematic patterns of TKA designs. Various fluoroscopic studies have focused on determination of kinematics but haven't defined differentiators that affect motion patterns. This research study assesses the importance of the cruciate ligaments and femoral geometry for Bi-Cruciate Retaining (BCR) and Posterior Cruciate Retaining (PCR) TKAs having the same femoral component, compared to the normal knee.

Methods

The in vivo 3D kinematics were determined for 40 subjects having a PCR TKA, 10 having a BCR TKA, and 10 having a normal knee, in a retrospective study. All TKA subjects had the same femoral component. All subjects performed a deep knee bend under fluoroscopic surveillance. The kinematics were determined during early flexion (ACL dominant), mid flexion (ACL/PCL transition) and deep flexion (PCL dominant).


Introduction

Many fluoroscopic studies on total knee arthroplasty (TKA) have identified kinematic variabilities compared to the normal knee, with many subjects experiencing paradoxical motion patterns. The intent of this study was to investigate the results of a newly designed PCR TKA to determine kinematic variabilities and assess these kinematic patterns with those previously documented for the normal knee.

Methods

The study involves determining the in vivo kinematics for 80 subjects compared to the normal knee. 10 subjects have a normal knee, 40 have a Journey II PCR TKA and 40 subjects with the Journey II XR TKA (BCR). Although all PCR subjects have been evaluated, we are continuing to evaluate subjects with a BCR TKA. All TKAs were performed by a single surgeon and deemed clinically successful. All subjects performed a deep knee bend from full extension to maximum flexion while under fluoroscopic surveillance. Kinematics were calculated via 3D-to-2D registration at 30° increments from full extension to maximum flexion. Anterior/posterior translation of the medial (MAP) and lateral (LAP) femoral condyles and femorotibial axial rotation were compared during ranges of motion in relation to the function of the cruciate ligaments.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_3 | Pages 56 - 56
1 Feb 2017
Buzhardt P Smith L Bhowmik-Stoker M Stimac J
Full Access

Introduction

The use of cementless TKA's has been gradually increasing over the past several years given the increasing life expectancy of our patient population. Cementless TKA's have not been rapidly adopted due to the challenges and uncertainty of tibial fixation especially in elderly patients. With the advent of new technologies, the results of cementless TKA's with the potential for long term biologic fixation may now be equivalent or better than cemented TKA's. A highly porous tibial baseplate was developed based on proximal tibial anatomy using CT scans using 3D printing technology with focus on length, location and design of press-fit pegs.

Objectives

The purpose of this study was to review the early results with respect to fixation and complications using a new, highly porous cementless tibial baseplate designed for biologic fixation.


Orthopaedic Proceedings
Vol. 97-B, Issue SUPP_7 | Pages 21 - 21
1 May 2015
Pulido PG Smith L Honeyman C Langkamer V
Full Access

Presence of superficial wound infection following total joint replacement (TJR) increases risk of deep prosthetic infection and revision surgery. Early identification and management are advocated.

We conducted an audit to identify the number of suspected wound infections, treatment received, and whether diagnosis was supported by microbiological evidence. Early complication data were collected for all TJRs completed in a 12-month period (2012, n=314). Medical records were reviewed for all complications and summarised data were compared with data from 2010/11.

Forty-nine complications were recorded (47 in 2010/11) with increase in number of bacteriologically confirmed wound infections (from 2 to 6) and in number of serious wound infections (n=3).

Review of medical records showed that patients were treated in the community with antibiotics despite lack of objective microbiological evidence. Two of three serious wound infections were preceded by prolonged antibiotic prescription in the community.

Analysis of these results led to a new system for management of suspected wound infection in TJR patients. A ‘wound care card’ is issued at time of discharge and early assessment by a specialist orthopaedic nurse is available. Early results indicate a beneficial effect with potential to improve patient experience and long-term outcome, and to reduce overuse of antibiotics.


Orthopaedic Proceedings
Vol. 97-B, Issue SUPP_7 | Pages 14 - 14
1 May 2015
Smith L Wong J Cowie S Radford M Price M Langkamer V
Full Access

Unicompartmental knee replacement (UKR) is associated with higher revision rates than total knee replacement and it has been suggested that surgeons should receive specific training for this prosthesis. We investigated the outcome of all UKR in a district general hospital over ten years.

All patients who had received UKR from 2003 to 2013 were identified from theatre records, as were all revision knee arthroplasties. We contacted all patients (or their GP) with no known revision to ascertain UKR status. A life table analysis was used for three categories: all surgeons and types of UKR, Oxford UKR only and Oxford UKR by surgeons with specific training.

There were 319 UKR (one loss to follow up), four types of prosthesis, 21 failures and a 5-year cumulative survival rate of 91.54%. There were 310 Oxford UKR with 17 failures and 5-year survival 93.56%. Surgeons with training in use of Oxford UKR completed 242 replacements with 10 failures and 5-year survival of 95.68%.

In comparison with results for Oxford UKR in 11th annual NJR report, our results are satisfactory and support continued use of this prosthesis in a non-specialist centre. Our established programme of surveillance will monitor the survival of UKR in our hospital.