header advert
Results 1 - 2 of 2
Results per page:

Abstract

Objective

Radial to axillary nerve and spinal accessory (XI) to suprascapular nerve (SSN) transfers are standard procedures to restore function after C5 brachial plexus dysfunction. The anterior approach to the SSN may miss concomitant pathology at the suprascapular notch and sacrifices lateral trapezius function, resulting in poor restoration of shoulder external rotation. A posterior approach allows decompression and visualisation of the SSN at the notch and distal coaptation of the medial XI branch. The medial triceps has a double fascicle structure that may be coapted to both the anterior and posterior division of the axillary nerve, whilst preserving the stabilising effect of the long head of triceps at the glenohumeral joint. Reinnervation of two shoulder abductors and two external rotators may confer advantages over previous approaches with improved external rotation range of motion and strength.

Methods

Review of the clinical outcomes of 22 patients who underwent a double nerve transfer from XI and radial nerves. Motor strength was evaluated using the MRC scale and grade 4 was defined as the threshold for success.


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_11 | Pages 55 - 55
1 Nov 2022
Jimulia D Saad A Malik A
Full Access

Abstract

Background

Anterior cruciate ligament (ACL) injuries with coinciding posterolateral tibial plateau (PLTP) depression fractures are rare. According to the most up to date literature, addressing the PLTP is crucial in preventing failure of the ACL. However, the surgical management of these injuries pose a great challenge to orthopaedic surgeons, given the anatomical location of the depressed PTP fragment. We report a case of a 17-year-old patient presenting to our department with this injury and describe a novel fixation method, that has not been described in the literature.

Surgical Technique

A standard 2-portal arthroscopy is used to visualise the fractures. The PLTP is addressed first. With the combined use of arthroscopy and fluoroscopy, a guide pin is triangulated from the anteromedial aspect of the tibia, towards the depressed plateau fragment. Once the guide pin is approximately 1cm from the centre of the fragment, it is over-drilled with a cannulated drill, and simultaneously bluntly punched up to its original anatomical location. Bone graft is then used to fill the void, supported by two subchondral screws. Both fluoroscopy and arthroscopy are used to confirm adequacy of fixation. Finally, the tibial spine avulsion fracture is repaired arthroscopically using the standard suture bridging technique.