header advert
Results 1 - 4 of 4
Results per page:
Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_3 | Pages 103 - 103
23 Feb 2023
Gupta V Van Niekerk M Hirner M
Full Access

Scapular notching is a common problem following reverse shoulder arthroplasty (RSA). This is due to impingement between the humeral polyethylene cup and scapular neck in adduction and external rotation. Various glenoid component strategies have been described to combat scapular notching and enhance impingement-free range of motion (ROM). There is limited data available detailing optimal glenosphere position in RSA with an onlay configuration. The purpose of this study was to determine which glenosphere configurations would maximise impingement free ROM using an onlay RSA prosthesis.

A three-dimensional (3D) computed tomography (CT) scan of a shoulder with Walch A1, Favard E0 glenoid morphology was segmented using validated software. An onlay RSA prosthesis was implanted and a computer model simulated external rotation and adduction motion of the virtual RSA prosthesis. Four glenosphere parameters were tested; diameter (36mm, 41mm), lateralization (0mm, 3mm, 6mm), inferior tilt (neutral, 5 degrees, 10 degrees), and inferior eccentric positioning (0.5mm, 1.5mm. 2.5mm, 3.5mm, 4.5mm). Eighty-four combinations were simulated. For each simulation, the humeral neck-shaft angle was 147 degrees and retroversion was 30 degrees.

The largest increase in impingement-free range of motion resulted from increasing inferior eccentric positioning, gaining 15.0 degrees for external rotation and 18.8 degrees for adduction. Glenosphere lateralization increased external rotation motion by 13. 6 degrees and adduction by 4.3 degrees. Implanting larger diameter glenospheres increased external rotation and adduction by 9.4 and 10.1 degrees respectively. Glenosphere tilt had a negligible effect on impingement-free ROM.

Maximizing inferior glenosphere eccentricity, lateralizing the glenosphere, and implanting larger glenosphere diameters improves impingement-free range of motion, in particular external rotation, of an onlay RSA prosthesis. Surgeons’ awareness of these trends can help optimize glenoid component position to maximise impingement-free ROM for RSA. Further studies are required to validate these findings in the context of scapulothoracic motion and soft tissue constraints.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_3 | Pages 104 - 104
23 Feb 2023
Gupta V Zhou Y Manson J Watt J
Full Access

Surgical site infections (SSIs) after spinal fusion surgery increase healthcare costs, morbidity and mortality. Routine measures of obesity fail to consider site specific fat distribution. We aimed to assess the association between the spine adipose index and deep surgical site infection and determine a threshold value for spine adipose index that can assist in preoperative risk stratification in patients undergoing posterior instrumented lumbar fusion (PILF).

A multicentre retrospective case-control study was completed. We reviewed patients who underwent PILF from January 1, 2010 to December 31, 2018. All patients developing a deep primary incisional or organ-space SSI within 90 days of surgery as per US Centre for Disease Control and Prevention criteria were identified. We gathered potential pre-operative and intra-operative deep infection risk factors for each patient. Spine adipose index was measured on pre-operative mid-sagittal cuts of T2 weighted MRI scans. Each measurement was repeated twice by three authors in a blinded fashion, with each series of measurement separated by a period of at least six weeks.

Forty-two patients were included in final analysis, with twenty-one cases and twenty-one matched controls. The spine adipose index was significantly greater in patients developing deep SSI (p =0.029), and this relationship was maintained after adjusting for confounders (p=0.046). Risk of developing deep SSI following PILF surgery was increased 2.0-fold when the spine adipose index was ≥0.51. The spine adipose index had excellent (ICC >0.9; p <0.001) inter- and intra-observer reliabilities.

The spine adipose index is a novel radiographic measure and an independent risk factor for developing deep SSI, with 0.51 being the ideal threshold value for pre-operative risk stratification in patients undergoing PILF surgery.


Bone & Joint Open
Vol. 1, Issue 8 | Pages 494 - 499
18 Aug 2020
Karia M Gupta V Zahra W Dixon J Tayton E

Aims

The aim of this study is to determine the effects of the UK lockdown during the COVID-19 pandemic on the orthopaedic admissions, operations, training opportunities, and theatre efficiency in a large district general hospital.

Methods

The number of patients referred to the orthopaedic team between 1 April 2020 and 30 April 2020 were collected. Other data collected included patient demographics, number of admissions, number and type of operations performed, and seniority of primary surgeon. Theatre time was collected consisting of anaesthetic time, surgical time, time to leave theatre, and turnaround time. Data were compared to the same period in 2019.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_IV | Pages 153 - 153
1 Mar 2012
Pradhan N Gupta V Clarke V
Full Access

Aim

To evaluate the costs of performing revision hip and knee surgery at a District General Hospital.

Methods

A retrospective review of all revision hip and knee surgery between October 2004 and October 2006 was performed. Information was obtained from the notes and theatre log books. Each case was fully costed. The breakdown costs included implant choice, theatre time, length of stay, allograft, blood products and post-operative physiotherapy/OT. The costs were obtained from the hospital financial department and theatre invoices. Payment to the hospital is based on a specific tariff which in turn is determined by coding each patient episode. We individually coded every case, using the OPCS 4.3 coding system, and applied the appropriate tariff. The tariffs that the financial department had applied to each case were also available. A comparison was made between actual costs incurred, the expected reimbursement (from our study coding) and the actual reimbursement received (from finance department).