Vol. 90-B, Issue SUPP_I | Pages 181 - 181
1 Mar 2008
Poggie R Christie M Eilers V Hanssen A Lewallen D Lewis R O’Keefe T Stulberg D Sutherland C Unger A Gruen T
Full Access

Press-fit acetabular reconstructions have become the standard THA; however, controversies remain. The purpose of this study was to critically evaluate serial radiographs for initial cup stability, i.e. gaps and signs of periacetabular interface changes for a porous tantalum monoblock socket.

A multicenter study evaluating 574 primary THRs (542 patients) performed by 9 surgeons at 7 hospitals, all with a monoblock cup without screws. Analyses included clinical outcomes and detailed 2-year minimum radiographic evaluation by one independent observer (mean follow-up, 33 months).

Complications included 9 intra-operative acetabular fractures. Among the 123 cases excluded from radiographic evaluations: deceased (19), lost-to-follow-up (8), 7 early revisions (recurrent dislocations (6) and one trauma-related loosening), and sepsis (3). Patient demographics (414 hips): mean age 65 years (19–93); 58 percent females. Baseline radiographs revealed 113 zones in 85 hips (21 percent) with acetabular gaps; 36 in zone I, 72 in zone II, and 5 in zone III. Of these radiolucencies, 57 zones were 1 mm or less and 56 zones ranged from 2 to 5 mm. At last follow-up, 64 hips (75 percent) had complete gap fill-in, including 100 percent of gaps greater than 3 mm.

There were no socket migrations, no evidence of lysis, no revisions for loosening, and no complete periacetabular interface radiolucencies. The fill-in of preexisting OA cysts and gaps is attributed to adequate initial stability and osteointegration into the porous tantalum. These results suggest that a monoblock cup without screws is an attractive option in THA.