header advert
Results 1 - 1 of 1
Results per page:
Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXI | Pages 111 - 111
1 May 2012
R. WM R. BB K. DJC S. JM C. HR
Full Access

Hypothesis

The Synergy femoral component was introduced in 1996 as a second generation titanium proximally porous-coated tapered stem with dual offsets to help better restore femoral offset at THR. The purpose of this prospective study was to evaluate the long-term (minimum 10 year) clinical and radiographic results and survivorship of this femoral component at our institution.

Methods & Analysis

From 1996 to 1999, 256 cementless Synergy femoral components were inserted and followed prospectively in 254 patients requiring THR. 185 were standard offset stems (72.3%) while 71 stems (27.7%) were high offset. The average follow-up was 11.2 years (range 10.0 to 12.9 years). Average age at index THR was 58.9 year. Two hundred and eight stems had standard porous coating while 48 had additional HA coating. Fifty-two cases were either lost to follow-up or had died prior to 10 years follow-up. Patients were followed prospectively using validated clinical outcome scores and radiographs. Kaplan-Meier survival analysis was performed.