Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_14 | Pages 47 - 47
1 Mar 2013
Blake C Van Der Merwe J Human B
Full Access

Background

Using digital X-rays to plan a hip replacement can cause problems with sizing and templating the prosthesis. Using an AP view of both hips is desirable as this allows the use of the sometimes unaffected contralateral hip for templating.

Method

We devised a method of using a 20mm ball bearing as a marker positioned at the same depth as the greater trochanter, but between the patient's legs. Placing the marker between the patient's legs avoids the problem of the marker disappearing off the side of the X-ray, as is seen when placing the marker at the side of the obese patient. The marker is then used to calibrate the size of the digital X-ray. We used a hundred consecutive post-operative X-rays, comparing the size of the head of the femoral prosthesis used at surgery with the size measured pre-operatively using the marker.