Advertisement for orthosearch.org.uk
Results 1 - 100 of 2177
Results per page:
The Bone & Joint Journal
Vol. 101-B, Issue 6_Supple_B | Pages 116 - 122
1 Jun 2019
Whiteside LA Roy ME

Aims. The aims of this study were to assess the exposure and preservation of the abductor mechanism during primary total hip arthroplasty (THA) using the posterior approach, and to evaluate gluteus maximus transfer to restore abductor function of chronically avulsed gluteus medius and minimus. Patients and Methods. A total of 519 patients (525 hips) underwent primary THA using the posterior approach, between 2009 and 2013. The patients were reviewed preoperatively and at two and five years postoperatively. Three patients had mild acute laceration of the gluteus medius caused by retraction. A total of 54 patients had mild chronic damage to the tendon (not caused by exposure), which was repaired with sutures through drill holes in the greater trochanter. A total of 41 patients had severe damage with major avulsion of the gluteus medius and minimus muscles, which was repaired with sutures through bone and a gluteus maximus flap transfer to the greater trochanter. Results. Abductor strength was maintained in the normal hips, but lateral hip pain progressed significantly, five years postoperatively (p < 0.0001). In the 54 patients with mild abductor tendon damage treated with simple repair, lateral hip pain also increased significantly during follow-up (p = 0.002). In the 35 patients with severe avulsion but good muscle repaired using a gluteus maximus flap transfer, abductor function was restored. The six patients with complete avulsion and poor muscle did not regain strong abductor power, but lateral hip pain decreased. Conclusion. The posterior approach offered excellent exposure and preservation of the abductor mechanism during primary THA. Augmentation of the repair with a gluteus maximus flap provided stable reconstruction of the abductor muscles and seemed to restore function in the hips with functioning muscles. Cite this article: Bone Joint J 2019;101-B(6 Supple B):116–122


The Bone & Joint Journal
Vol. 100-B, Issue 11 | Pages 1524 - 1532
1 Nov 2018
Angélico ACC Garcia LM Icuma TR Herrero CF Maranho DA

Aims. The aims of this study were to evaluate the abductor function in moderate and severe slipped capital femoral epiphysis (SCFE), comparing the results of a corrective osteotomy at the base of the femoral neck and osteoplasty with 1) in situ epiphysiodesis for mild SCFE, 2) contralateral unaffected hips, and 3) hips from healthy individuals. Patients and Methods. A total of 24 patients (mean age 14.9 years (. sd. 1.6); 17 male and seven female patients) with moderate or severe SCFE (28 hips) underwent base of neck osteotomy and osteoplasty between 2012 and 2015. In situ epiphysiodesis was performed in seven contralateral hips with mild slip. A control cohort was composed of 15 healthy individuals (mean age 16.5 years (. sd. 2.5); six male and nine female patients). The abductor function was assessed using isokinetic dynamometry and range of abduction, with a minimum one-year follow-up. Results. We found no differences in mean peak abductor torque between the hips that underwent osteotomy and those that received in situ epiphysiodesis (p = 0.63), but the torque was inferior in comparison with contralateral hips without a slip (p < 0.01) and hips from control individuals (p < 0.001). The abduction strength was positively correlated with the range of hip abduction (R = 0.36; p < 0.001). Conclusion. Although the abductor strength was not restored to normal levels, moderate and severe SCFE treated with osteotomy at the base of the femoral neck and osteoplasty showed abductor function similar to in situ epiphysiodesis in hips with less severe displacement. Cite this article: Bone Joint J 2018;100-B:1524–32


The Bone & Joint Journal
Vol. 95-B, Issue 3 | Pages 343 - 347
1 Mar 2013
Odak S Ivory J

Deficiency of the abductor mechanism is a well-recognised cause of pain and limping after total hip replacement (THR). This can be found incidentally at the time of surgery, or it may arise as a result of damage to the superior gluteal nerve intra-operatively, or after surgery owing to mechanical failure of the abductor muscle repair or its detachment from the greater trochanter. The incidence of abductor failure has been reported as high as 20% in some studies. The management of this condition remains a dilemma for the treating surgeon. We review the current state of knowledge concerning post-THR abductor deficiency, including the aetiology, diagnosis and management, and the outcomes of surgery for this condition. Cite this article: Bone Joint J 2013;95-B:343–7


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 11 | Pages 1579 - 1582
1 Nov 2012
Abdelaziz TH Samir S Magdy W

A total of 35 children with Erb’s palsy and shoulder abduction of < 90° underwent transfer of teres major. In 18 cases (group 1) a trapezius transfer was added (combined procedure). In 17 cases (group 2) teres major transfer was carried out in isolation (single procedure). The mean gain in abduction was 67.2° (60° to 80°) in group 1 and 37.6° (20° to 70°) in group 2, which reached statistical significance (p < 0.001). Group 2 was further divided into those who had deltoid power of < M3 (group 2a) and those with deltoid power ≥ M3 (group 2b). The difference in improvement of abduction between groups 2a and group 2b was statistically significant (p < 0.001) but the difference between group 2b and group 1 was not (p = 0.07). We recommend the following protocol of management: in children with abduction ≥ 90° a single procedure is indicated. In children with abduction < 90°: a combined procedure is indicated if deltoid power is < M3 and a single procedure is indicated if deltoid power is ≥ M3. If no satisfactory improvement is achieved, the trapezius can be transferred at a later stage.


The Bone & Joint Journal
Vol. 97-B, Issue 8 | Pages 1050 - 1055
1 Aug 2015
Drexler M Abolghasemian M Kuzyk PR Dwyer T Kosashvili Y Backstein D Gross AE Safir O

This study reports the clinical outcome of reconstruction of deficient abductor muscles following revision total hip arthroplasty (THA), using a fresh–frozen allograft of the extensor mechanism of the knee. A retrospective analysis was conducted of 11 consecutive patients with a severe limp because of abductor deficiency which was confirmed on MRI scans. The mean age of the patients (three men and eight women) was 66.7 years (52 to 84), with a mean follow-up of 33 months (24 to 41). . Following surgery, two patients had no limp, seven had a mild limp, and two had a persistent severe limp (p = 0.004). The mean power of the abductors improved on the Medical Research Council scale from 2.15 to 3.8 (p < 0.001). Pre-operatively, all patients required a stick or walking frame; post-operatively, four patients were able to walk without an aid. Overall, nine patients had severe or moderate pain pre-operatively; ten patients had no or mild pain post-operatively. . At final review, the Harris hip score was good in five patients, fair in two and poor in four. . We conclude that using an extensor mechanism allograft is relatively effective in the treatment of chronic abductor deficiency of the hip after THA when techniques such as local tissue transfer are not possible. . Longer-term follow-up is necessary before the technique can be broadly applied. Cite this article: Bone Joint J 2015;97-B:1050–5


Bone & Joint Open
Vol. 3, Issue 10 | Pages 795 - 803
12 Oct 2022
Liechti EF Attinger MC Hecker A Kuonen K Michel A Klenke FM

Aims. Traditionally, total hip arthroplasty (THA) templating has been performed on anteroposterior (AP) pelvis radiographs. Recently, additional AP hip radiographs have been recommended for accurate measurement of the femoral offset (FO). To verify this claim, this study aimed to establish quantitative data of the measurement error of the FO in relation to leg position and X-ray source position using a newly developed geometric model and clinical data. Methods. We analyzed the FOs measured on AP hip and pelvis radiographs in a prospective consecutive series of 55 patients undergoing unilateral primary THA for hip osteoarthritis. To determine sample size, a power analysis was performed. Patients’ position and X-ray beam setting followed a standardized protocol to achieve reproducible projections. All images were calibrated with the KingMark calibration system. In addition, a geometric model was created to evaluate both the effects of leg position (rotation and abduction/adduction) and the effects of X-ray source position on FO measurement. Results. The mean FOs measured on AP hip and pelvis radiographs were 38.0 mm (SD 6.4) and 36.6 mm (SD 6.3) (p < 0.001), respectively. Radiological view had a smaller effect on FO measurement than inaccurate leg positioning. The model showed a non-linear relationship between projected FO and femoral neck orientation; at 30° external neck rotation (with reference to the detector plane), a true FO of 40 mm was underestimated by up to 20% (7.8 mm). With a neutral to mild external neck rotation (≤ 15°), the underestimation was less than 7% (2.7 mm). The effect of abduction and adduction was negligible. Conclusion. For routine THA templating, an AP pelvis radiograph remains the gold standard. Only patients with femoral neck malrotation > 15° on the AP pelvis view, e.g. due to external rotation contracture, should receive further imaging. Options include an additional AP hip view with elevation of the entire affected hip to align the femoral neck more parallel to the detector, or a CT scan in more severe cases. Cite this article: Bone Jt Open 2022;3(10):795–803


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 5 | Pages 620 - 626
1 May 2007
Nath RK Paizi M

Residual muscle weakness in obstetric brachial plexus palsy results in soft-tissue contractures which limit the functional range of movement and lead to progressive glenoid dysplasia and joint instability. We describe the results of surgical treatment in 98 patients (mean age 2.5 years, 0.5 to 9.0) for the correction of active abduction of the shoulder. The patients underwent transfer of the latissimus dorsi and teres major muscles, release of contractures of subscapularis pectoralis major and minor, and axillary nerve decompression and neurolysis (the modified Quad procedure). The transferred muscles were sutured to the teres minor muscle, not to a point of bony insertion. The mean pre-operative active abduction was 45° (20° to 90°). At a mean follow-up of 4.8 years (2.0 to 8.7), the mean active abduction was 162° (100° to 180°) while 77 (78.6%) of the patients had active abduction of 160° or more. No decline in abduction was noted among the 29 patients (29.6%) followed up for six years or more. This procedure involving release of the contracted internal rotators of the shoulder combined with decompression and neurolysis of the axillary nerve greatly improves active abduction in young patients with muscle imbalance secondary to obstetric brachial plexus palsy


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXIX | Pages 233 - 233
1 Sep 2012
Thomson S Napier R Thompson N
Full Access

Introduction. Dislocation is one of the most common complications following total hip arthroplasty. The literature suggests a frequency of 1–3% for primary total hip replacement (THR) and 7–10% for revision procedures. No definitive treatment algorithm exists for their management, with some surgeons attempting to constrain hip motion with casting or bracing initially. The evidence for this practice is limited. The purpose of this study was to determine the current practice for managing THR dislocation within our unit, and to determine the effectiveness of abduction bracing. Method. A retrospective case-note analysis was performed on all patients admitted with a dislocated THR between 01/01/08 and 31/12/10. Patients were categorised into three groups: first time dislocators, recurrent dislocators, or dislocation occurring following revision surgery. The following data was collected; time from original surgery, closed or open reduction, surgical approach, prescription of abduction brace post-operatively, and the number of subsequent dislocations. Any patients who underwent open reduction were excluded from the study. Results. A total of 45 patients were included in the study. Of the first time dislocators, 75% treated with abduction brace re-dislocated, and 26% of patients treated without bracing re-dislocated. In the recurrent group 63% had been braced after their initial dislocation. Conclusion. Based on this study the benefit of abduction braces is limited and patient compliance tends to be poor. The cost of these appliances is significant (£450/£525) and patients typically have a prolonged hospital stay for ordering and application. Our unit has subsequently discontinued the use of such braces. Goals to reducing THR dislocation remain; meticulous preoperative planning and patient selection, accurate component positioning with intraoperative stability testing, good soft tissue repair, and early patient education


The Journal of Bone & Joint Surgery British Volume
Vol. 80-B, Issue 2 | Pages 284 - 287
1 Mar 1998
Giurea A Paternostro T Heinz-Peer G Kaider A Gottsauner-Wolf F

We compared two methods of reconstruction of the abductor mechanism in 15 patients after prosthetic replacement of the upper femur, to assess abductor strength and function. Six patients in group I had direct fixation of the gluteus medius tendon and a segment of the original bone to the prosthesis. Nine patients in group 2 had the abductor tendon fixed to the iliotibial band. We assessed clinical function, isometric muscle strength and muscle cross-sectional area for each patient. The patients in group 1 had better clinical and functional results (p = 0.059), with average peak torques for hip abduction of 92% of that in the non-operated leg in group 1, and of 57% in group 2. Group 1 had a mean muscle cross-sectional area of 69% and a mean value of strength per cross-sectional area of 134% when compared with the control side. The respective values for group 2 were 52% and 91%. Direct fixation of the abductor muscles to the prostheses gave improved function and higher isometric abductor muscle force


The Journal of Bone & Joint Surgery British Volume
Vol. 70-B, Issue 4 | Pages 561 - 565
1 Aug 1988
Rietveld A Daanen H Rozing P Obermann W

Fourteen cases of hemiarthroplasty for four-part fractures of the proximal humerus were reviewed. Pain relief was satisfactory, but function was limited, mainly due to loss of glenohumeral abduction despite electromyographic proof of actively contracting abductors in all cases. Analysis of special radiographs of nine cases showed a direct relationship between the clinical results and the "humeral offset", or distance between the geometric centre of the humeral head and the lateral aspect of the greater tuberosity. This offset affects the lever arms of the glenohumeral abductor muscles. The implications for surgical technique and for the design of shoulder prostheses are discussed


Bone & Joint Research
Vol. 13, Issue 9 | Pages 485 - 496
13 Sep 2024
Postolka B Taylor WR Fucentese SF List R Schütz P

Aims. This study aimed to analyze kinematics and kinetics of the tibiofemoral joint in healthy subjects with valgus, neutral, and varus limb alignment throughout multiple gait activities using dynamic videofluoroscopy. Methods. Five subjects with valgus, 12 with neutral, and ten with varus limb alignment were assessed during multiple complete cycles of level walking, downhill walking, and stair descent using a combination of dynamic videofluoroscopy, ground reaction force plates, and optical motion capture. Following 2D/3D registration, tibiofemoral kinematics and kinetics were compared between the three limb alignment groups. Results. No significant differences for the rotational or translational patterns between the different limb alignment groups were found for level walking, downhill walking, or stair descent. Neutral and varus aligned subjects showed a mean centre of rotation located on the medial condyle for the loaded stance phase of all three gait activities. Valgus alignment, however, resulted in a centrally located centre of rotation for level and downhill walking, but a more medial centre of rotation during stair descent. Knee adduction/abduction moments were significantly influenced by limb alignment, with an increasing knee adduction moment from valgus through neutral to varus. Conclusion. Limb alignment was not reflected in the condylar kinematics, but did significantly affect the knee adduction moment. Variations in frontal plane limb alignment seem not to be a main modulator of condylar kinematics. The presented data provide insights into the influence of anatomical parameters on tibiofemoral kinematics and kinetics towards enhancing clinical decision-making and surgical restoration of natural knee joint motion and loading. Cite this article: Bone Joint Res 2024;13(9):485–496


The Bone & Joint Journal
Vol. 105-B, Issue 12 | Pages 1303 - 1313
1 Dec 2023
Trammell AP Hao KA Hones KM Wright JO Wright TW Vasilopoulos T Schoch BS King JJ

Aims. Both anatomical and reverse total shoulder arthroplasty (aTSA and rTSA) provide functional improvements. A reported benefit of aTSA is better range of motion (ROM). However, it is not clear which procedure provides better outcomes in patients with limited foward elevation (FE). The aim of this study was to compare the outcome of aTSA and rTSA in patients with glenohumeral osteoarthritis (OA), an intact rotator cuff, and limited FE. Methods. This was a retrospective review of a single institution’s prospectively collected shoulder arthroplasty database for TSAs undertaken between 2007 and 2020. A total of 344 aTSAs and 163 rTSAs, which were performed in patients with OA and an intact rotator cuff with a minimum follow-up of two years, were included. Using the definition of preoperative stiffness as passive FE ≤ 105°, three cohorts were matched 1:1 by age, sex, and follow-up: stiff aTSAs (85) to non-stiff aTSAs (85); stiff rTSAs (74) to non-stiff rTSAs (74); and stiff rTSAs (64) to stiff aTSAs (64). We the compared ROMs, outcome scores, and complication and revision rates. Results. Compared with non-stiff aTSAs, stiff aTSAs had poorer passive FE and active external rotation (ER), whereas there were no significant postoperative differences between stiff rTSAs and non-stiff rTSAs. There were no significant differences in preoperative function when comparing stiff aTSAs with stiff rTSAs. However, stiff rTSAs had significantly greater postoperative active and passive FE (p = 0.001 and 0.004, respectively), and active abduction (p = 0.001) compared with stiff aTSAs. The outcome scores were significantly more favourable in stiff rTSAs for the Shoulder Pain and Disability Index, Simple Shoulder Test, American Shoulder and Elbow Surgeons score, University of California, Los Angeles score, and the Constant score, compared with stiff aTSAs. When comparing the proportion of stiff aTSAs versus stiff rTSAs that exceeded the minimal clinically important difference and substantial clinical benefit, stiff rTSAs achieved both at greater rates for all measurements except active ER. The complication rate did not significantly differ between stiff aTSAs and stiff rTSAs, but there was a significantly higher rate of revision surgery in stiff aTSAs (p = 0.007). Conclusion. Postoperative overhead ROM, outcome scores, and rates of revision surgery favour the use of a rTSA rather than aTSA in patients with glenohumeral OA, an intact rotator cuff and limited FE, with similar rotational ROM in these two groups. Cite this article: Bone Joint J 2023;105-B(12):1303–1313


The Journal of Bone & Joint Surgery British Volume
Vol. 77-B, Issue 6 | Pages 865 - 869
1 Nov 1995
McGrory B Morrey B Cahalan T An K Cabanela M

At a minimum of one year after operation, we studied 64 patients with 86 total hip arthroplasties (THA) by standard anteroposterior hip and pelvic radiographs and measurement of range of motion and of isometric abduction strength. The femoral offset correlated positively with the range of abduction (p = 0.046). Abduction strength correlated positively with both femoral offset (p = 0.0001) and the length of the abductor lever arm (p = 0.005). Using multiple regression, abduction strength correlated with height (p = 0.017), gender (p = 0.0005), range of flexion (p = 0.047) and the abductor lever arm (p = 0.060). Our findings suggest that greater femoral offset after THA allows both an increased range of abduction and greater abductor strength


The Bone & Joint Journal
Vol. 97-B, Issue 3 | Pages 405 - 411
1 Mar 2015
Fukiage K Futami T Ogi Y Harada Y Shimozono F Kashiwagi N Takase T Suzuki S

We describe our experience in the reduction of dislocation of the hip secondary to developmental dysplasia using ultrasound-guided gradual reduction using flexion and abduction continuous traction (FACT-R). During a period of 13 years we treated 208 Suzuki type B or C complete dislocations of the hip in 202 children with a mean age of four months (0 to 11). The mean follow-up was 9.1 years (five to 16). The rate of reduction was 99.0%. There were no recurrent dislocations, and the rate of avascular necrosis of the femoral head was 1.0%. The rate of secondary surgery for residual acetabular dysplasia was 19.2%, and this was significantly higher in those children in whom the initial treatment was delayed or if other previous treatments had failed (p = 0.00045). The duration of FACT-R was significantly longer in severe dislocations (p = 0.001) or if previous treatments had failed (p = 0.018). . This new method of treatment is effective and safe in these difficult cases and offers outcomes comparable to or better than those of standard methods. Cite this article: Bone Joint J 2015;97-B:405–11


The Journal of Bone & Joint Surgery British Volume
Vol. 84-B, Issue 1 | Pages 104 - 107
1 Jan 2002
Jari S Paton RW Srinivasan MS

Between 1992 and 1997, we undertook a prospective, targeted clinical and ultrasonographic hip screening programme to assess the relationship between ultrasonographic abnormalities of the hip and clinical limitation of hip abduction. A total of 5.9% (2 of 34) of neonatal dislocatable hips and 87.5% (7 of 8) of ‘late’ dislocated hips seen after the age of six months, presented with unilateral limitation of hip abduction. All major (Graf type III) and 44.5% of minor (Graf type II) dysplastic hips presented with this sign. Statistically, bilateral limitation of hip abduction was not a useful clinical indicator of underlying hip abnormality because of its poor sensitivity, but unilateral limitation of abduction of the hip was a highly specific (90%) and reasonably sensitive sign (70%). It was more sensitive than the neonatal Ortolani manoeuvre, which has been considered to be the method of choice. It was, however, not sensitive enough to be of value as a routine screening test in developmental dysplasia of the hip. We consider unilateral limitation of hip abduction to be an important clinical sign and its presence in an infant over the age of three to four months makes further investigation essential


The Journal of Bone & Joint Surgery British Volume
Vol. 68-B, Issue 2 | Pages 275 - 277
1 Mar 1986
Elsworth C Walker G

The Denis Browne abduction harness was used in the management of 127 abnormal hips in 104 children at Queen Mary's Hospital for Children from 1966 to 1980, both as the initial treatment for unstable hips recognised soon after birth, and for children presenting later and whose hips first required reduction by gradual abduction in traction. The incidence of significant avascular necrosis was 3.1%, and occurred only in the primary treatment group, emphasising again the need for gentle care of infant hips. There have been no other significant complications and the appliance has functioned well


Bone & Joint Open
Vol. 2, Issue 12 | Pages 1067 - 1074
1 Dec 2021
El-Bakoury A Khedr W Williams M Eid Y Hammad AS

Aims. After failed acetabular fractures, total hip arthroplasty (THA) is a challenging procedure and considered the gold standard treatment. The complexity of the procedure depends on the fracture pattern and the initial fracture management. This study’s primary aim was to evaluate patient-reported outcome measures (PROMs) for patients who underwent delayed uncemented acetabular THA after acetabular fractures. The secondary aims were to assess the radiological outcome and the incidence of the associated complications in those patients. Methods. A total of 40 patients underwent cementless acetabular THA following failed treatment of acetabular fractures. The postoperative clinical and radiological outcomes were evaluated for all the cohort. Results. The median (interquartile range (IQR)) Oxford Hip Score (OHS) improved significantly from 9.5 (7 to 11.5), (95% confidence interval (CI) (8 to 10.6)) to 40 (39 to 44), (95% CI (40 to 43)) postoperatively at the latest follow-up (p < 0.001). It was worth noting that the initial acetabular fracture type (simple vs complex), previous acetabular treatment (ORIF vs conservative), fracture union, and restoration of anatomical centre of rotation (COR) did not affect the final OHS. The reconstructed centre of rotation (COR) was restored in 29 (72.5%) patients. The mean abduction angle in whom acetabular fractures were managed conservatively was statistically significantly higher than the surgically treated patients 42.6° (SD 7.4) vs 38° (SD 5.6)) (p = 0.032). We did not have any case of acetabular or femoral loosening at the time of the last follow-up. We had two patients with successful two-stage revision for infection with overall eight-year survival rate was 95.2% (95% CI 86.6% to 100%) with revision for any reason at a median (IQR) duration of follow-up 50 months (16 to 87) months following THA. Conclusion. Delayed cementless acetabular THA in patients with previous failed acetabular fracture treatments produces good clinical outcomes (PROMS) with excellent survivorship, despite the technically demanding nature of the procedure. The initial fracture treatment does not influence the outcome of delayed THA. In selected cases of acetabular fractures (either nondisplaced or with secondary congruency), the initial nonoperative treatment neither resulted in large acetabular defects nor required additional acetabular reconstruction at the time of THA. Cite this article: Bone Jt Open 2021;2(12):1067–1074


The Journal of Bone & Joint Surgery British Volume
Vol. 68-B, Issue 1 | Pages 61 - 64
1 Jan 1986
Quain S Catterall A

Hinge abduction is an abnormal movement of the hip which occurs when a femoral head, deformed as a result of avascular necrosis or Perthes' disease, fails to slide within the acetabulum. Patients with this condition present with pain and shortening and in some cases arthrodesis has been recommended. We report 27 cases in which the diagnosis had been established by arthrography. The satisfactory results of abduction-extension osteotomy of the femur in 26 hips with this condition are reported


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 9 | Pages 1256 - 1259
1 Sep 2008
Kedgley AE DeLude JA Drosdowech DS Johnson JA Bicknell RT

This study compared the effect of a computer-assisted and a traditional surgical technique on the kinematics of the glenohumeral joint during passive abduction after hemiarthroplasty of the shoulder for the treatment of fractures. We used seven pairs of fresh-frozen cadaver shoulders to create simulated four-part fractures of the proximal humerus, which were then reconstructed with hemiarthroplasty and reattachment of the tuberosities. The specimens were randomised, so that one from each pair was repaired using the computer-assisted technique, whereas a traditional hemiarthroplasty without navigation was performed in the contralateral shoulder. Kinematic data were obtained using an electromagnetic tracking device. The traditional technique resulted in posterior and inferior translation of the humeral head. No statistical differences were observed before or after computer-assisted surgery. Although it requires further improvement, the computer-assisted approach appears to allow glenohumeral kinematics to more closely replicate those of the native joint, potentially improving the function of the shoulder and extending the longevity of the prosthesis


The Journal of Bone & Joint Surgery British Volume
Vol. 86-B, Issue 5 | Pages 726 - 730
1 Jul 2004
Yoo WJ Choi IH Chung CY Cho T Kim HY

We studied, clinically and radiologically, the growth and remodelling of 21 hips after valgus femoral osteotomy with both rotational and sagittal correction for hinge abduction in 21 patients (mean age, 9.7 years) with Perthes’ disease. The exact type of osteotomy performed was based on the pre-operative clinical and radiological assessment and the results of intra-operative dynamic arthrography. The mean IOWA hip score was 66 (34 to 76) before surgery and 92 (80 to 100) at a mean follow-up of 7.1 years (3.0 to 15.0). Radiological measurements revealed favourable remodelling of the femoral head and improved hip joint mechanics. Valgus osteotomy, with both rotational and sagittal correction, can improve symptoms, function and remodelling of the hip in patients with Perthes’ disease


The Journal of Bone & Joint Surgery British Volume
Vol. 76-B, Issue 5 | Pages 834 - 836
1 Sep 1994
Itoi E Newman Kuechle D Morrey B An K

The stabilising effects on the glenohumeral joint of each of the rotator-cuff muscles and of the biceps were studied with the arm in abduction and external rotation in 13 cadaver shoulders. The muscles were loaded one at a time with forces proportional to their cross-sectional areas. We recorded the positions of the humeral head before and after the application to the humerus of an anterior force of 1.5 kg. When the capsule was intact, the anterior displacement with the subscapularis loaded was significantly larger than with the other muscles loaded (p = 0.0009). With the capsule vented, the displacement with the biceps loaded was significantly smaller than that with the subscapularis loaded (p = 0.0052). After creating an imitation Bankart lesion, the displacement with the biceps loaded was significantly less than with any of the rotator-cuff muscles loaded (p = 0.0132). We conclude that in the intact shoulder, the subscapularis is the least important anterior stabiliser, and that the biceps becomes more important than the rotator-cuff muscles as stability from the capsuloligamentous structure decreases. Strengthening of the biceps as well as the rotator-cuff muscles should be part of the rehabilitation programme for anterior shoulder instability


The Journal of Bone & Joint Surgery British Volume
Vol. 82-B, Issue 4 | Pages 548 - 554
1 May 2000
Bankes MJK Catterall A Hashemi-Nejad A

Valgus extension osteotomy (VGEO) is a salvage procedure for ‘hinge abduction’ in Perthes’ disease. The indications for its use are pain and fixed deformity. Our study shows the clinical results at maturity of VGEO carried out in 48 children (51 hips) and the factors which influence subsequent remodelling of the hip. After a mean follow-up of ten years, total hip replacement has been carried out in four patients and arthrodesis in one. The average Iowa Hip Score in the remainder was 86 (54 to 100). Favourable remodelling of the femoral head was seen in 12 hips. This was associated with three factors at surgery; younger age (p = 0.009), the phase of reossification (p = 0.05) and an open triradiate cartilage (p = 0.0007). Our study has shown that, in the short term, VGEO relieves pain and corrects deformity; as growth proceeds it may produce useful remodelling in this worst affected subgroup of children with Perthes’ disease


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 5 | Pages 700 - 704
1 May 2011
Janicki JA Wright JG Weir S Narayanan UG

The Ponseti method of clubfoot management requires a period of bracing in order to maintain correction. This study compared the effectiveness of ankle foot orthoses and Denis Browne boots and bar in the prevention of recurrence following successful initial management. Between 2001 and 2003, 45 children (69 feet) with idiopathic clubfeet achieved full correction following Ponseti casting with or without a tenotomy, of whom 17 (30 clubfeet) were braced with an ankle foot orthosis while 28 (39 clubfeet) were prescribed with Denis Browne boots and bar. The groups were similar in age, gender, number of casts and tenotomy rates. The mean follow-up was 60 months (50 to 72) in the ankle foot orthosis group and 47 months (36 to 60) in the group with boots and bars. Recurrence requiring additional treatment occurred in 25 of 30 (83%) of the ankle foot orthosis group and 12 of 39 (31%) of the group with boots and bars (p < 0.001). Additional procedures included repeat tenotomy (four in the ankle foot orthosis group and five in the group treated with boot and bars), limited posterior release with or without tendon transfers (seven in the ankle foot orthosis group and two in the group treated with boots and bars), posteromedial releases (nine in the orthosis group) and midfoot osteotomies (five in the orthosis group, p < 0.001). Following initial correction by the Ponseti method, children managed with boots and bars had far fewer recurrences than those managed with ankle foot orthoses. Foot abduction appears to be important to maintain correction of clubfeet treated by the Ponseti method, and this cannot be achieved with an ankle foot orthosis


The Bone & Joint Journal
Vol. 105-B, Issue 4 | Pages 455 - 464
15 Mar 2023
de Joode SGCJ Meijer R Samijo S Heymans MJLF Chen N van Rhijn LW Schotanus MGM

Aims

Multiple secondary surgical procedures of the shoulder, such as soft-tissue releases, tendon transfers, and osteotomies, are described in brachial plexus birth palsy (BPBP) patients. The long-term functional outcomes of these procedures described in the literature are inconclusive. We aimed to analyze the literature looking for a consensus on treatment options.

Methods

A systematic literature search in healthcare databases (PubMed, Embase, the Cochrane library, CINAHL, and Web of Science) was performed from January 2000 to July 2020, according to the Preferred Reporting Items for Systematic Reviews and Meta-Analysis guidelines. The quality of the included studies was assessed with the Cochrane ROBINS-I risk of bias tool. Relevant trials studying BPBP with at least five years of follow-up and describing functional outcome were included.


Bone & Joint Open
Vol. 4, Issue 7 | Pages 496 - 506
5 Jul 2023
Theunissen WWES Van der Steen MC Van Veen MR Van Douveren FQMP Witlox MA Tolk JJ

Aims

The aim of this study was to identify the information topics that should be addressed according to the parents of children with developmental dysplasia of the hip (DDH) in the diagnostic and treatment phase during the first year of life. Second, we explored parental recommendations to further optimize the information provision in DDH care.

Methods

A qualitative study with semi-structured interviews was conducted between September and December 2020. A purposive sample of parents of children aged younger than one year, who were treated for DDH with a Pavlik harness, were interviewed until data saturation was achieved. A total of 20 interviews with 22 parents were conducted. Interviews were audio recorded, transcribed verbatim, independently reviewed, and coded into categories and themes.


The Journal of Bone & Joint Surgery British Volume
Vol. 66-B, Issue 2 | Pages 180 - 183
1 Mar 1984
Nutton R Checketts R

A series of 167 patients with Charnley-type total hip replacements were studied retrospectively to determine the incidence of trochanteric non-union, the degree of postoperative trochanteric displacement, and the relation between these two complications. The power in the hip abductor muscles, measured with a load-cell device, was significantly reduced if the trochanteric fragment had displaced proximally by more than 3 cm; 12% of those studied fell into this group and, as a consequence, had a poorer result. It was concluded that displacement of the trochanter was of greater importance than bony union in determining function in the replaced hip. Because these unwanted problems may compromise an otherwise successful operation, it is suggested tentatively that trochanteric osteotomy should be abandoned except for difficult primary operations or for revision procedures.


The Journal of Bone & Joint Surgery British Volume
Vol. 69-B, Issue 3 | Pages 479 - 480
1 May 1987
Bhansali R Bhansali R


The Bone & Joint Journal
Vol. 105-B, Issue 12 | Pages 1327 - 1332
1 Dec 2023
Morris WZ Kak A Mayfield LM Kang MS Jo C Kim HKW

Aims. Abduction bracing is commonly used to treat developmental dysplasia of the hip (DDH) following closed reduction and spica casting, with little evidence to support or refute this practice. The purpose of this study was to determine the efficacy of abduction bracing after closed reduction in improving acetabular index (AI) and reducing secondary surgery for residual hip dysplasia. Methods. We performed a retrospective review of patients treated with closed reduction for DDH at a single tertiary referral centre. Demographic data were obtained including severity of dislocation based on the International Hip Dysplasia Institute (IHDI) classification, age at reduction, and casting duration. Patients were prescribed no abduction bracing, part-time, or full-time wear post-reduction and casting. AI measurements were obtained immediately upon cast removal and from two- and four-year follow-up radiographs. Results. A total of 243 hips underwent closed reduction and 82% (199/243) were treated with abduction bracing. There was no difference between those treated with or without bracing with regard to sex, age at reduction, severity of dislocation, spica duration, or immediate post-casting AI (all p > 0.05). There was no difference in hips treated with or without abduction brace with regard to AI at two years post-reduction (32.4° (SD 5.3°) vs 30.9° (SD 4.6°), respectively; p = 0.099) or at four years post-reduction (26.4° (SD 5.2°) vs 25.4° (SD 5.1°), respectively; p = 0.231). Multivariate analysis revealed only IHDI grade predicted AI at two years post-reduction (p = 0.004). There was no difference in overall rate of secondary surgery for residual dysplasia between hips treated with or without bracing (32% vs 39%, respectively; p = 0.372). However, there was an increased risk of early secondary surgery (< two years post-reduction) in the non-braced group (11.4% vs 2.5%; p = 0.019). Conclusion. Abduction bracing following closed reduction for DDH treatment is not associated with decreased residual dysplasia at two or four years post-reduction but may reduce rates of early secondary surgery. A prospective study is indicated to provide more definitive recommendations. Cite this article: Bone Joint J 2023;105-B(12):1327–1332


The Bone & Joint Journal
Vol. 105-B, Issue 2 | Pages 198 - 208
1 Feb 2023
Cheok T Smith T Wills K Jennings MP Rawat J Foster B

Aims. We investigated the prevalence of late developmental dysplasia of the hip (DDH), abduction bracing treatment, and surgical procedures performed following the implementation of universal ultrasound screening versus selective ultrasound screening programmes. Methods. A systematic search of PubMed, Embase, The Cochrane Library, OrthoSearch, and Web of Science from the date of inception of each database until 27 March 2022 was performed. The primary outcome of interest was the prevalence of late detection of DDH, diagnosed after three months. Secondary outcomes of interest were the prevalence of abduction bracing treatment and surgical procedures performed in childhood for dysplasia. Only studies describing the primary outcome of interest were included. Results. A total of 31 studies were identified, of which 13 described universal screening and 20 described selective screening. Two studies described both. The prevalence of late DDH was 0.10 per 1,000 live births (95% confidence interval (CI) 0.00 to 0.39) in the universal screening group and 0.45 per 1,000 live births (95% CI 0.31 to 0.61) in the selective screening group. Abduction bracing treatment was performed on 55.54 per 1,000 live births (95% CI 24.46 to 98.15) in the universal screening group versus 0.48 per 1,000 live births (95% CI 0.07 to 1.13) in the selective screening group. Both the universal and selective screening groups had a similar prevalence of surgical procedures in childhood for dysplasia being performed (0.48 (95% CI 0.32 to 0.63) vs 0.49 (95% CI 0.31 to 0.71) per 1,000 live births, respectively). Conclusion. Universal screening showed a trend towards lower prevalence of late DDH compared to selective screening. However, it was also associated with a significant increase in the prevalence of abduction bracing without a significant reduction in the prevalence of surgical procedures in childhood for dysplasia being performed. High-quality studies comparing both treatment methods are required, in addition to studies into the natural history of missed DDH. Cite this article: Bone Joint J 2023;105-B(2):198–208


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_16 | Pages 32 - 32
19 Aug 2024
Caplash G Caplash Y Copson D Thewlis D Ehrlich A Solomon LB Ramasamy B
Full Access

Few surgical techniques to reconstruct the abductor mechanism of the hip have been reported, with outcomes reported only from case reports and small case series from the centres that described the techniques. As in many of our revision THA patients the gluteus maximus was affected by previous repeat posterior approaches, we opted to reconstruct the abductor mechanism using a vastus lateralis to gluteus medius transfer. We report the results of such reconstructions in seven patients, mean age 66 (range, 53–77), five females, presenting with severe abductor deficiency (MRC grade 1–2). Five patients had previous revision THA, two with a proximal femoral replacement, one patient had a primary THA after a failed malunited trochanteric fracture, and one patient had a native hip with idiopathic fatty infiltration of glutei of >90%. All patients had instrumented gait analysis, and surface electromyography (EMG) of the glutei, TFL, and vastus muscles simultaneously before surgery and at each post-op follow-up. Postoperatively, patients were allowed to weight bear as tolerated and were requested to wear an abduction brace for the first six weeks after surgery to protect the transfer. All patients improved after surgery and reached an abductor power of 3 or more. All patients walked without support six months after surgery and were satisfied with the result. Abductor function continued to improve beyond one year of follow-up, and some patients reached an abductor power of 5. EMG demonstrated that the transferred vastus lateralis started firing synchronously with gluteus medius after three months post-surgery, suggesting adaptation to its new function. No knee extension weakness was recorded. One patient complained of lateral thigh numbness and was dissatisfied with the cosmetic look of her thigh after surgery. Our preliminary results are encouraging and comparable with those achieved by the originators of the technique


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_12 | Pages 17 - 17
1 Dec 2022
Kowalski E Dervin G Lamontagne M
Full Access

One in five patients remain unsatisfied due to ongoing pain and impaired mobility following total knee arthroplasty (TKA). It is important if surgeons can pre-operatively identify which patients may be at risk for poor outcomes after TKA. The purpose of this study was to determine if there is an association between pre-operative measures and post-operative outcomes in patients who underwent TKA. This study included 28 patients (female = 12 / male = 16, age = 63.6 ± 6.9, BMI = 29.9 ± 7.4 kg/m2) with knee osteoarthritis who were scheduled to undergo TKA. All surgeries were performed by the same surgeon (GD), and a subvastus approach was performed for all patients. Patients visited the gait lab within one-month of surgery and 12 months following surgery. At the gait lab, patients completed the knee injury and osteoarthritis outcome score (KOOS), a timed up and go (TUG), and walking task. Variables of interest included the five KOOS sub-scores (symptoms, pain, activities of daily living, sport & recreation, and quality of life), completion time for the TUG, walking speed, and peak knee biomechanics variables (flexion angle, abduction moment, power absorption). A Pearson's product-moment correlation was run to assess the relationship between pre-operative measures and post-operative outcomes in the TKA patients. Preliminary analyses showed the relationship to be linear with all variables normally distributed, as assessed by Shapiro-Wilk's test (p > .05), and there were no outliers. There were no statistically significant correlations between any of the pre-operative KOOS sub-scores and any of the post-operative biomechanical outcomes. Pre-operative TUG time had a statistically significant, moderate positive correlation with post-operative peak knee abduction moments [r(14) = .597, p < .001] and peak knee power absorption [r(14) = .498, p = .007], with pre-operative TUG time explaining 36% of the variability in peak knee abduction moment and 25% of the variability in peak knee power absorption. Pre-operative walking speed had a statistically significant, moderate negative correlation with post-operative peak knee abduction moments [r(14) = -.558, p = .002] and peak knee power absorption [r(14) = -.548, p = .003], with pre-operative walking speed explaining 31% of the variability in peak knee abduction moment and 30% of the variability in peak knee power absorption. Patient reported outcome measures (PROMs), such as the KOOS, do indicate the TKA is generally successful at relieving pain and show an overall improvement. However, their pre-operative values do not correlate with any biomechanical indicators of post-operative success, such as peak knee abduction moment and knee power. Shorter pre-operative TUG times and faster pre-operative walking speeds were correlated with improved post-operative biomechanical outcomes. These are simple tasks surgeons can implement into their clinics to evaluate their patients. Future research should expand these findings to a larger sample size and to determine if other factors, such as surgical approach or implant design, improves patient outcomes


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_11 | Pages 57 - 57
1 Nov 2022
Prem R West B Jenner E Bolton L Deshmukh S
Full Access

Abstract. Aim. This study aims to Inter and intra observer reliability compare, use of a standard goniometer (SG) to measure intermetacarpal angle (degrees) vs use of a new technique of using a digital vernier calliper (DVC) (mm) to measure the distance between the first and second metacarpal head. Method. Maximal active abduction and extension of both thumbs was measured in 20 healthy volunteers on two occasions at least one week apart by two assessors. Results. The inter and intra-observer agreement was higher & the variance of the data was lower using the DVC with the new technique than the SG for both thumb abduction and extension. Additionally, the correlation between measurement of extension and abduction was higher using the DVC than the SG. Conclusion. Whilst both tools provide acceptable intra and inter-observer agreement, the new technique using a DVC is consistently better and more reliable than a SG in measuring thumb abduction and extension. The study also supports our hypothesis that the thumb rotates around the second metacarpal head with a consistent radius


The Bone & Joint Journal
Vol. 106-B, Issue 5 Supple B | Pages 105 - 111
1 May 2024
Apinyankul R Hong C Hwang KL Burket Koltsov JC Amanatullah DF Huddleston JI Maloney WJ Goodman SB

Aims. Instability is a common indication for revision total hip arthroplasty (THA). However, even after the initial revision, some patients continue to have recurrent dislocation. The aim of this study was to assess the risk for recurrent dislocation after revision THA for instability. Methods. Between 2009 and 2019, 163 patients underwent revision THA for instability at Stanford University Medical Center. Of these, 33 (20.2%) required re-revision due to recurrent dislocation. Cox proportional hazard models, with death and re-revision surgery for periprosthetic infection as competing events, were used to analyze the risk factors, including the size and alignment of the components. Paired t-tests or Wilcoxon signed-rank tests were used to assess the outcome using the Veterans RAND 12 (VR-12) physical and VR-12 mental scores, the Harris Hip Score (HHS) pain and function, and the Hip disability and Osteoarthritis Outcome score for Joint Replacement (HOOS, JR). Results. The median follow-up was 3.1 years (interquartile range 2.0 to 5.1). The one-year cumulative incidence of recurrent dislocation after revision was 8.7%, which increased to 18.8% at five years and 31.9% at ten years postoperatively. In multivariable analysis, a high American Society of Anesthesiologists (ASA) grade (hazard ratio (HR) 2.72 (95% confidence interval (CI) 1.13 to 6.60)), BMI between 25 and 30 kg/m. 2. (HR 4.31 (95% CI 1.52 to 12.27)), the use of specialized liners (HR 5.39 (95% CI 1.97 to 14.79) to 10.55 (95% CI 2.27 to 49.15)), lumbopelvic stiffness (HR 6.03 (95% CI 1.80 to 20.23)), and postoperative abductor weakness (HR 7.48 (95% CI 2.34 to 23.91)) were significant risk factors for recurrent dislocation. Increasing the size of the acetabular component by > 1 mm significantly decreased the risk of dislocation (HR 0.89 (95% CI 0.82 to 0.96)). The VR-12 physical and HHS (pain and function) scores improved significantly at mid term. Conclusion. Patients requiring revision THA for instability are at risk of recurrent dislocation. Higher ASA grades, being overweight, a previous lumbopelvic fusion, the use of specialized liners, and postoperative abductor weakness are significant risk factors. Cite this article: Bone Joint J 2024;106-B(5 Supple B):105–111


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_13 | Pages 91 - 91
1 Dec 2022
Rizkallah M Aoude A Turcotte R
Full Access

Resection of the proximal femur raises several challenges to the orthopedic oncology surgeon. Among these is the re-establishment of the abductor mechanism that might impacts on hip function. Extent of tumor resection and surgeons’ preferences dictate the reconstruction method of the abductors. While some surgeons advocate the necessity of greater trochanter (GT) preservation whenever possible, others attempt direct soft tissues reattachment to the prosthesis. Sparse data in the literature evaluated the outcomes of greater trochanter fixation to the proximal femur megaprosthesis. This is a retrospective monocentric study. All patients who received a proximal femoral replacement after tumor resection between 2005 and 2021 with a minimum follow-up of three months were included. Patients were divided into two groups: (1) those with preserved GT reattached to the megaprosthesis and (2) those with direct or indirect (tenodesis to fascia lata) abductor muscles reattachment. Both groups were compared for surgical outcomes (dislocation and revision rates) and functional outcomes (Trendelenburg gait, use of walking-assistive device and abductor muscle strength). Additionally patients in group 1 were subdivided into patients who received GT reinsertion using a grip and cables and those who got direct GT reinsertion using suture materials and studied for GT displacement at three, six and 12 months. Time to cable rupture was recorded and analyzed through a survival analysis. Fifty-six patients were included in this study with a mean follow-up of 45 months (3-180). There were 23 patients with reinserted GT (group 1) and 33 patients with soft tissue repair (group 2). Revision rate was comparable between both groups(p=0.23); however, there were more dislocations in group 2 (0/23 vs 6/33; p=0.037). Functional outcomes were comparable, with 78% of patients in group 1 (18/23) and 73% of patients in group 2 (24/33) that displayed a Trendelenburg gait (p=0.76). In group 1, 70% (16/23) used walking aids compared to 79% of group 2 (27/33) (p=0.34). Mean abductor strength reached 2.7 in group 1 compared to 2.3 in group 2 (p=0.06). In group 1, 16 of the 23 patients had GT reinsertion with grip and cables. Median survival of cables for these 16 patients reached 13 months in our series. GT displacement reached a mean of two mm, three mm, and 11 mm respectively at three, six and 12 months of follow-up in patients with grip and cables compared to 12 mm, 24 mm and 26 mm respectively at the same follow-up intervals in patients with GT stand-alone suture reinsertion(p<0.05). Although GT preservation and reinsertion did not improve functional outcomes after proximal femur resection and reconstruction with a megaprosthesis, it was significantly associated with lower dislocation rate despite frequent cable failure and secondary GT migration. No cable or grip revision or removal was recorded. Significantly less displacement was observed in patients for whom GT reattachment used plate and cables rather than sutures only. Therefore we suggest that GT should be preserved and reattached whenever possible and that GT reinsertion benefits from strong materials such as grip and cables


The Bone & Joint Journal
Vol. 106-B, Issue 5 Supple B | Pages 89 - 97
1 May 2024
Scholz J Perka C Hipfl C

Aims. There is little information in the literature about the use of dual-mobility (DM) bearings in preventing re-dislocation in revision total hip arthroplasty (THA). The aim of this study was to compare the use of DM bearings, standard bearings, and constrained liners in revision THA for recurrent dislocation, and to identify risk factors for re-dislocation. Methods. We reviewed 86 consecutive revision THAs performed for dislocation between August 2012 and July 2019. A total of 38 revisions (44.2%) involved a DM bearing, while 39 (45.3%) and nine (10.5%) involved a standard bearing and a constrained liner, respectively. Rates of re-dislocation, re-revision for dislocation, and overall re-revision were compared. Radiographs were assessed for the positioning of the acetabular component, the restoration of the centre of rotation, leg length, and offset. Risk factors for re-dislocation were determined by Cox regression analysis. The modified Harris Hip Scores (mHHSs) were recorded. The mean age of the patients at the time of revision was 70 years (43 to 88); 54 were female (62.8%). The mean follow-up was 5.0 years (2.0 to 8.75). Results. DM bearings were used significantly more frequently in elderly patients (p = 0.003) and in hips with abductor deficiency (p < 0.001). The re-dislocation rate was 13.2% for DM bearings compared with 17.9% for standard bearings, and 22.2% for constrained liners (p = 0.432). Re-revision-free survival for DM bearings was 84% (95% confidence interval (CI) 0.77 to 0.91) compared with 74% (95% CI 0.67 to 0.81) for standard articulations, and 67% (95% CI 0.51 to 0.82) for constrained liners (p = 0.361). Younger age (hazard ratio (HR) 0.92 (95% CI 0.85 to 0.99); p = 0.031), lower comorbidity (HR 0.44 (95% CI 0.20 to 0.95); p = 0.037), smaller heads (HR 0.80 (95% CI 0.64 to 0.99); p = 0.046), and retention of the acetabular component (HR 8.26 (95% CI 1.37 to 49.96); p = 0.022) were significantly associated with re-dislocation. All DM bearings which re-dislocated were in patients with abductor muscle deficiency (HR 48.34 (95% CI 0.03 to 7,737.98); p = 0.303). The radiological analysis did not reveal a significant relationship between restoration of the geometry of the hip and re-dislocation. The mean mHHSs significantly improved from 43 points (0 to 88) to 67 points (20 to 91; p < 0.001) at the final follow-up, with no differences between the types of bearing. Conclusion. We found that the use of DM bearings reduced the rates of re-dislocation and re-revision in revision THA for recurrent dislocation, but did not guarantee stability. Abductor deficiency is an important predictor of persistent instability. Cite this article: Bone Joint J 2024;106-B(5 Supple B):89–97


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_12 | Pages 79 - 79
1 Dec 2022
Langohr GD Mahaffy M Athwal G Johnson JA
Full Access

Patients receiving reverse total shoulder arthroplasty (RTSA) often have osseous erosions because of glenohumeral arthritis, leading to increased surgical complexity. Glenoid implant fixation is a primary predictor of the success of RTSA and affects micromotion at the bone-implant interface. Augmented implants which incorporate specific geometry to address superior erosion are currently available, but the clinical outcomes of these implants are still considered short-term. The objective of this study was to investigate micromotion at the glenoid-baseplate interface for a standard, 3 mm and 6 mm lateralized baseplates, half-wedge, and full-wedge baseplates. It was hypothesized that the mechanism of load distribution from the baseplate to the glenoid will differ between implants, and these varying mechanisms will affect overall baseplate micromotion. Clinical CT scans of seven shoulders (mean age 69 years, 10°-19° glenoid inclinations) that were classified as having E2-type glenoid erosions were used to generate 3D scapula models using MIMICS image processing software (Materialise, Belgium) with a 0.75 mm mesh size. Each scapula was then repeatedly virtually reconstructed with the five implant types (standard,3mm,6mm lateralized, and half/full wedge; Fig.1) positioned in neutral version and inclination with full backside contact. The reconstructed scapulae were then imported into ABAQUS (SIMULIA, U.S.) finite element software and loads were applied simulating 15°,30°,45°,60°,75°, and 90° of abduction based on published instrumented in-vivo implant data. The micromotion normal and tangential to the bone surface, and effective load transfer area were recorded for each implant and abduction angle. A repeated measures ANOVA was used to perform statistical analysis. Maximum normal micromotion was found to be significantly less when using the standard baseplate (5±4 μm), as opposed to the full-wedge (16±7 μm, p=0.004), 3 mm lateralized (10±6 μm, p=0.017), and 6 mm lateralized (16±8 μm, p=0.007) baseplates (Fig.2). The half-wedge baseplate (11±7 μm) also produced significantly less micromotion than the full-wedge (p=0.003), and the 3 mm lateralized produced less micromotion than the full wedge (p=0.026) and 6 mm lateralized (p=0.003). Similarly, maximum tangential micromotion was found to be significantly less when using the standard baseplate (7±4 μm), as opposed to the half-wedge (12±5 μm, p=0.014), 3 mm lateralized (10±5 μm, p=0.003), and 6 mm lateralized (13±6 μm, p=0.003) baseplates (Fig.2). The full wedge (11±3 μm), half-wedge, and 3 mm lateralized baseplate also produced significantly less micromotion than the 6 mm lateralized (p=0.027, p=012, p=0.02, respectively). Both normal and tangential micromotion were highest at the 30° and 45° abduction angles (Fig.2). The effective load transfer area (ELTA) was lowest for the full wedge, followed by the half wedge, 6mm, 3mm, and standard baseplates (Fig.3) and increased with abduction angle. Glenoid baseplates with reduced lateralization and flat backside geometries resulted in the best outcomes with regards to normal and tangential micromotion. However, these types of implants are not always feasible due to the required amount of bone removal, and medialization of the bone-implant interface. Future work should study the acceptable levels of bone removal for patients with E-type glenoid erosion and the corresponding best implant selections for such cases. For any figures or tables, please contact the authors directly


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_12 | Pages 24 - 24
23 Jun 2023
Byrd JWT Jones KS Bardowski EA
Full Access

Partial thickness abductor tendon tears are a significant source of recalcitrant laterally based hip pain. For those that fail conservative treatment, the results of endoscopic repair are highly successful with minimal morbidity. The principal burden is the protracted rehabilitation that is necessary as part of the recovery process. There is a wide gap between failed conservative treatment and successful surgical repair. It is hypothesized that a non-repair surgical strategy, such as a bioinducitve patch, could significantly reduce the burden associated recovery from a formal repair. Thus, the purpose of this study is to report the preliminary results of this treatment strategy. Symptomatic partial thickness abductor tendon tears are treated conservatively, including activity modification, supervised physical therapy and ultrasound guided corticosteroid injections. Beginning in January 2022, patients undergoing hip arthroscopy for intraarticular pathology who also had persistently symptomatic partial thickness abductor tendon tears, were treated with adjunct placement of a bioinducitve (Regeneten) patch over the tendon lesion from the peritrochanteric space. The postop rehab protocol is dictated by the intraarticular procedure performed. All patients are prospectively assessed with a modified Harris Hip Score (mHHS) and iHOT and the tendon healing response examined by ultrasound. Early outcomes will be presented on nine consecutive cases. Conclusions - Will be summarized based on the preliminary outcomes to be reported


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_9 | Pages 2 - 2
16 May 2024
Schwagten K
Full Access

Background. Iatrogenic hallux varus is a rare complication after hallux valgus surgery. Operative treatment comprises a wide variety of techniques, of which the reversed transfer of the abductor hallucis tendon is the most recent described technique. Methods. This paper will present the long-term clinical results of the reversed transfer of the abductor hallucis longus. Therefore, we performed a prospective clinical observational study on 16 female patients. Our hypothesis is that the tendon transfer will persist in a good alignment and patient satisfaction on long term. There is a 100% follow-up rate with a range from 10 to 101 months. Patients were subjected to a clinical examination, three questionnaires and their general satisfaction. Results. Out of 16 patients, at time of follow-up, we found a positive correlation between the subjective outcome score and alignment (r = 0.59), and between the general satisfaction and alignment (r = 0.77). Based on the general satisfaction we achieved a success satisfaction rate of 69% (11 patients). The other 31% (5 patients) patient group was only satisfied with major reservations or not satisfied at all. The two most invalidating complications were a coronal or sagittal malalignment or the combination of both. Conclusion. Our results suggest that the reverse abductor hallucis tendon transfer is a good technique to treat a supple iatrogenic hallux varus with an observed success satisfaction rate of 69% at a mean follow-up time of 48 (range 10–101) months. However, patients should be informed that on the long-term loss of correction is possible


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_15 | Pages 77 - 77
7 Nov 2023
Dey R Nortje M du Toit F Grobler G Dower B
Full Access

Hip abductor tears(AT) have long been under-recognized, under-reported and under-treated. There is a paucity of data on the prevalence, morphology and associated factors. Patients with “rotator cuff tears of the hip” that are recognized and repaired during total hip arthroplasty(THA) report comparable outcomes to patients with intact abductor tendons at THA. The study was a retrospective review of 997 primary THA done by a single surgeon from 2012–2022. Incidental findings of AT identified during the anterolateral approach to the hip were documented with patient name, gender, age and diagnosis. The extent and size of the tears of the Gluteus medius and Minimus were recorded. Xrays and MRI's were collected for the 140 patients who had AT and matched 1:1 with respect to age and gender against 140 patients that had documented good muscle quality and integrity. Radiographic measurements (Neck shaft angle, inter-teardrop distance, Pelvis width, trochanteric width and irregularities, bodyweight moment arm and abductor moment arm) were compared between the 2 groups in an effort to determine if any radiographic feature would predict AT. The prevalence of AT were 14%. Females had statistically more tears than males(18vs10%), while patients over the age of 70y had statistically more tears overall(19,7vs10,4%), but also more Gluteus Medius tears specifically(13,9vs5,3%). Radiographic measurements did not statistically differ between the tear and control group, except for the presence of trochanteric irregularities. MRI's showed that 50% of AT were missed and subsequently identified during surgery. Abductor tears are still underrecognized and undertreated during THA which can results in inferior outcomes. The surgeon should have an high index of suspicion in elderly females with trochanteric irregularities and although an MRI for every patient won't be feasible, one should always be prepared and equipped to repair the abductor tendons during THA


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_8 | Pages 26 - 26
11 Apr 2023
Kowalski E Pelegrinelli A Ryan N Dervin G Lamontagne M
Full Access

This study examined pre-operative measures to predict post-operative biomechanical outcomes in total knee arthroplasty (TKA) patients. Twenty-eight patients (female=12/male=16, age=63.6±6.9, BMI=29.9±7.4 kg/m2) with knee osteoarthritis scheduled to undergo TKA were included. All surgeries were performed by the same surgeon (GD) with a subvastus approach. Patients visited the gait lab within one-month prior to surgery and 12 months following surgery. At the gait lab, patients completed the knee injury and osteoarthritis outcome score (KOOS), a timed up and go (TUG), maximum knee flexion and extension strength evaluation, and a walking task. Variables of interest included the five KOOS sub-scores, TUG time, maximum knee flexion and extension strength normalized to body weight, walking speed, and peak knee biomechanics variables (flexion angle, abduction moment, power absorption). A Pearson's correlation was used to identify significantly correlated variables which were then inputted into a multiple regression. No assumption violations for the multiple regression existed for any variables. Pre-operative knee flexion and extension strength, TUG time, and age were used in the multiple regression. The multiple regression model statistically significantly predicted peak knee abduction moment, post-operative walking speed, and post-operative knee flexion strength. All four variables added statistically significantly to the prediction p<.05. Pre-operative KOOS values did not correlate with any biomechanical indicators of post-operative success. Age, pre-operative knee flexion and extension strength, and TUG times predicted peak knee abduction moment, which is associated with medial knee joint loading. These findings stress the importance of pre-surgery condition, as stronger individuals achieved better post-operative biomechanical outcomes. Additionally, younger patients had better outcomes, suggesting that surgeons should not delay surgery in younger patients. This delay in surgery may prevent patients from achieving optimal outcomes. Future studies should utilize a hierarchical multiple regression to identify which variables are most predictive


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_11 | Pages 8 - 8
4 Jun 2024
Safdar NZ Chapman G Hopwood J Brockett C Redmond A
Full Access

Ankle fusion (AF), a durable intervention for ankle arthritis, has been the management of choice but restricts mobility. Recently, total ankle replacement (TAR) has been offered to patients looking to maintain mobility. The aim was to compare the biomechanics of AF and TAR while walking on inverted and everted slopes which create a greater demand for complex foot mobility than level walking. A ten-camera motion detection setup captured trials as patients walked in both directions over a 5⁰ lateral slope with embedded force plates. Moments (Nm/Kg) across the knee and ankle were exported from Visual 3D in the sagittal and frontal plane, and data were reported as means with 95% confidence intervals. 15 patients were recruited (6 TAR, 9 AF). The median age, follow-up and BMI was 67 years, 4 years and 35.8 kg/m² in AF, and 73 years, 7 years and 28.1 kg/m² in TAR, respectively. During inverted slope walking (4 TAR, 7 AF), abduction moments across (i) the knee: TAR 0.38 (0.37–0.39) vs AF 0.37 (0.27–0.52) and (ii) the ankle: TAR 0.20 (0.13–0.27) vs AF 0.25 (0.18–0.32), and extension moments across (i) the knee: TAR 0.68 (0.38–0.97) vs AF 0.85 (0.69–1.01) and (ii) the ankle: TAR 1.46 (1.30–1.62) vs AF 1.30 (1.08–1.52). During everted walking (5 TAR, 7 AF), abduction moments across (i) the knee: TAR 0.41 (0.30–0.52) vs AF 0.46 (0.27–0.66) and (ii) the ankle: TAR 0.24 (0.11–0.38) vs AF 0.26 (0.18–0.33), and extension moments across (i) the knee: TAR 0.76 (0.54–0.99) vs AF 0.93 (0.72–1.14) and (ii) the ankle: TAR 1.39 (1.19–1.59) vs AF 1.26 (1.04–1.48). There were no differences in abduction moments during inverted or everted slope walking. However, patients with AF had increased extension moments across the knee, particularly on inverted slopes, suggesting that AF creates a greater demand for knee compensation than TAR


Abstract. Objective. Radial to axillary nerve and spinal accessory (XI) to suprascapular nerve (SSN) transfers are standard procedures to restore function after C5 brachial plexus dysfunction. The anterior approach to the SSN may miss concomitant pathology at the suprascapular notch and sacrifices lateral trapezius function, resulting in poor restoration of shoulder external rotation. A posterior approach allows decompression and visualisation of the SSN at the notch and distal coaptation of the medial XI branch. The medial triceps has a double fascicle structure that may be coapted to both the anterior and posterior division of the axillary nerve, whilst preserving the stabilising effect of the long head of triceps at the glenohumeral joint. Reinnervation of two shoulder abductors and two external rotators may confer advantages over previous approaches with improved external rotation range of motion and strength. Methods. Review of the clinical outcomes of 22 patients who underwent a double nerve transfer from XI and radial nerves. Motor strength was evaluated using the MRC scale and grade 4 was defined as the threshold for success. Results. 18/22 patients had adequate follow-up (Mean: 29.5 months). Of these, 72.2% achieved ≥grade 4 power of shoulder abduction and a mean range of motion of 103°. 64.7% achieved ≥grade 4 external rotation with a mean range of motion of 99.6°. Conclusions. The results suggest the use of the combined nerve transfer for restoration of shoulder function via a posterior approach, involving the medial head branch of triceps to the axillary nerve and the XI to SSN


Bone & Joint Open
Vol. 2, Issue 6 | Pages 365 - 370
1 Jun 2021
Kolodychuk N Su E Alexiades MM Ren R Ojard C Waddell BS

Aims. Traditionally, acetabular component insertion during total hip arthroplasty (THA) is visually assisted in the posterior approach and fluoroscopically assisted in the anterior approach. The present study examined the accuracy of a new surgeon during anterior (NSA) and posterior (NSP) THA using robotic arm-assisted technology compared to two experienced surgeons using traditional methods. Methods. Prospectively collected data was reviewed for 120 patients at two institutions. Data were collected on the first 30 anterior approach and the first 30 posterior approach surgeries performed by a newly graduated arthroplasty surgeon (all using robotic arm-assisted technology) and was compared to standard THA by an experienced anterior (SSA) and posterior surgeon (SSP). Acetabular component inclination, version, and leg length were calculated postoperatively and differences calculated based on postoperative film measurement. Results. Demographic data were similar between groups with the exception of BMI being lower in the NSA group (27.98 vs 25.2; p = 0.005). Operating time and total time in operating room (TTOR) was lower in the SSA (p < 0.001) and TTOR was higher in the NSP group (p = 0.014). Planned versus postoperative leg length discrepancy were similar among both anterior and posterior surgeries (p > 0.104). Planned versus postoperative abduction and anteversion were similar among the NSA and SSA (p > 0.425), whereas planned versus postoperative abduction and anteversion were lower in the NSP (p < 0.001). Outliers > 10 mm from planned leg length were present in one case of the SSP and NSP, with none in the anterior groups. There were no outliers > 10° in anterior or posterior for abduction in all surgeons. The SSP had six outliers > 10° in anteversion while the NSP had none (p = 0.004); the SSA had no outliers for anteversion while the NSA had one (p = 0.500). Conclusion. Robotic arm-assisted technology allowed a newly trained surgeon to produce similarly accurate results and outcomes as experienced surgeons in anterior and posterior hip arthroplasty. Cite this article: Bone Jt Open 2021;2(6):365–370


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_15 | Pages 22 - 22
7 Nov 2023
Du Plessis J Kazee N Lewis A Steyn S Van Deventer S
Full Access

The choice of whether to perform antegrade intramedullary nailing (IMN) or plate fixation (PF) poses a conundrum for the surgeon who must strike the balance between anatomical restoration while reducing elbow and shoulder functional impairment. Most humeral middle third shaft fractures are amenable to conservative management given the considerable acceptable deformity and anatomical compensation by patients. This study is concerned with the patient reported outcomes regarding shoulder and elbow function for IMN and PF respectively. A prospective cohort study following up all the cases treated surgically for middle third humeral fractures from 2016 to 2022 at a single centre. Telephonically an analogue pain score, an American Shoulder and Elbow Society (ASES) score for shoulder function and the Oxford Elbow score (OES) for elbow function were obtained. One hundred and three patients met the inclusion criteria. Twenty four patients participated in the study, fifteen had IMN (62.5%) and nine had PF (37.5%.). The shoulder function outcomes showed no statistical difference with an average ASES score of sixty-six for the IMN group and sixty-nine for the PF group. Women and employed individuals expressed greater functional impairment. Hand dominance has no impact on the scores of elbow and shoulder function post operatively. The impairment of abduction score post antegrade nailing was higher in the antegrade nailing group than the plated group. The OES demonstrated greater variance in elbow function in the PF group with the IMN group expressing greater elbow disfunction. This study confirms that treatment of middle third humerus shaft fractures by plate fixation is marginally superior to antegrade intramedullary nailing in preserving elbow function and abduction ability


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_8 | Pages 76 - 76
11 Apr 2023
Petersen E Rytter S Koppens D Dalsgaard J Bæk Hansen T Larsen NE Andersen M Stilling M
Full Access

In an attempt to alleviate symptoms of the disease, patients with knee osteoarthrosis (KOA) frequently alter their gait patterns. Understanding the underlying pathomechanics and identifying KOA phenotypes is essential for improving treatments. We aimed to investigate altered kinematics in patients with KOA to identify subgroups. Sixty-six patients with symptomatic KOA scheduled for total knee arthroplasty and 12 age-matched healthy volunteers with asymptomatic knees were included. We used k-means to separate the patients based on dynamic radiostereometric assessed knee kinematics. Ligament lesions, KOA score, and clinical outcome were assessed by magnetic resonance imaging, radiographs, and patient reported outcome measures, respectively. We identified four clusters that were supported by clinical characteristics. Compared with the healthy group; The flexion group (n=20): revealed increased flexion, greater adduction, and joint narrowing and consisted primarily of patients with medial KOA. The abduction group (n=17): revealed greater abduction, joint narrowing and included primarily patients with lateral KOA. The anterior draw group (n=10): revealed greater anterior draw, external tibial rotation, lateral tibial shift, adduction, and joint narrowing. This group was composed of patients with medial KOA, some degree of anterior cruciate ligament lesion and the greatest KOA score. The external rotation group (n=19): revealed greater external tibial rotation, lateral tibial shift, adduction, and joint narrowing while no anterior draw was observed. This group included primarily patients with medial collateral and posterior cruciate ligament lesions. Patients with KOA can, based on their gait patterns, be classified into four subgroups, which relate to their clinical characteristics. The findings add to our understanding of associations between disease pathology characteristics in the knee and the pathomechanics in patients with KOA. A next step is to investigate if patients in the pathomechanic clusters have different outcomes following total knee arthroplasty


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_7 | Pages 87 - 87
4 Apr 2023
Gehweiler D Pastor T Gueorguiev B Jaeger M Lambert S
Full Access

The periclavicular space is a conduit for the brachial plexus and subclavian-axillary vascular system. Changes in its shape/form generated by alteration in the anatomy of its bounding structures, e.g. clavicle malunion, cause distortion of the containing structures, particularly during arm motion, leading to syndromes of thoracic outlet stenosis etc., or alterations of scapular posture with potential reduction in shoulder function. Aim of this study was developing an in vitro methodology for systematic and repeatable measurements of the clinically poorly characterized periclavicular space during arm motion using CT-imaging and computer-aided 3D-methodologies. A radiolucent frame, mountable to the CT-table, was constructed to fix an upper torso in an upright position with the shoulder joint lying in the isocentre. The centrally osteotomized humerus is fixed to a semi-circular bracket mounted centrally at the end of the frame. All arm movements (ante-/retroversion, abduction/elevation, in-/external rotation) can be set and scanned in a defined and reproducible manner. Clavicle fractures healed in malposition can be simulated by osteotomy and fixation using a titanium/carbon external fixator. During image processing the first rib served as fixed reference in space. Clavicle, scapula and humerus were registered, segmented, and triangulated. The different positions were displayed as superimposed surface meshes and measurements performed automatically. Initial results of an intact shoulder girdle demonstrated that different arm positions including ante-/retroversion and abduction/elevation resulted solely in a transverse movement of the clavicle along/parallel to the first rib maintaining the periclavicular space. A radiolucent frame enabling systematic and reproducible CT scanning of upper torsos in various arm movements was developed and utilized to characterize the effect on the 3D volume of the periclavicular space. Initial results demonstrated exclusively transverse movement of the clavicle along/parallel to the first rib maintaining the periclavicular space during arm positions within a physiological range of motion


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_12 | Pages 10 - 10
23 Jun 2023
Apinyankul R Hong C Hwang K Koltsov JCB Amanatullah DF Huddleston JI Maloney WJ Goodman SB
Full Access

Instability is a common indication for revision total hip arthroplasty (THA). However, even after the initial revision, some patients continue to have recurrent dislocations. This study investigates those at risk for recurrent dislocation after revision THA for instability at a single institution. Between 2009 and 2019, 163 patients underwent revision THA for instability at a single institution. Thirty-three of these patients required re-revision THA due to recurrent dislocation. Cox proportional hazard models with death as a competing event were used to analyze risk factors, including prosthesis sizing and alignment. Paired t-tests or Wilcoxon signed rank tests were used to assess patient outcomes (Veterans RAND 12 (VR-12) physical score, VR-12 mental score, Harris Hip Score, and hip disability and osteoarthritis outcome score for joint replacement). Duration of follow-up until either re-revision or final follow-up was a mean of 45.3 ± 38.2 months. The 1-year cumulative incidence for recurrent dislocation after revision was 8.7%, which increased to 19.6% at 5 years and 32.9% at 10 years postoperatively. In the multivariable analysis, high ASA score [HR 2.71], being underweight (BMI<18 kg/m. 2. ) [HR 36.26] or overweight/obese (BMI>25 kg/m. 2. ) [HR 4.31], use of specialized liners [HR 5.51–10.71], lumbopelvic stiffness [HR 6.29], and postoperative abductor weakness [HR 7.20] were significant risk factors for recurrent dislocation. Increasing the cup size decreased the dislocation risk [HR 0.89]. The dual mobility construct did not affect the risk for recurrent dislocation in univariate or multivariable analyses. VR-12 physical and HHS (pain and function) scores improved postoperatively at midterm. Patients requiring revision THA for instability are at risk for recurrent dislocation. Higher ASA scores, abnormal BMI, use of special liners, lumbopelvic stiffness, and postoperative abductor weakness are significant risk factors for re-dislocation


The Bone & Joint Journal
Vol. 102-B, Issue 11 | Pages 1438 - 1445
1 Nov 2020
Jang YH Lee JH Kim SH

Aims. Scapular notching is thought to have an adverse effect on the outcome of reverse total shoulder arthroplasty (RTSA). However, the matter is still controversial. The aim of this study was to determine the clinical impact of scapular notching on outcomes after RTSA. Methods. Three electronic databases (PubMed, Cochrane Database, and EMBASE) were searched for studies which evaluated the influence of scapular notching on clinical outcome after RTSA. The quality of each study was assessed. Functional outcome scores (the Constant-Murley scores (CMS), and the American Shoulder and Elbow Surgeons (ASES) scores), and postoperative range of movement (forward flexion (FF), abduction, and external rotation (ER)) were extracted and subjected to meta-analysis. Effect sizes were expressed as weighted mean differences (WMD). Results. In all, 11 studies (two level III and nine level IV) were included in the meta-analysis. All analyzed variables indicated that scapular notching has a negative effect on the outcome of RTSA . Statistical significance was found for the CMS (WMD –3.11; 95% confidence interval (CI) –4.98 to –1.23), the ASES score (WMD –6.50; 95% CI –10.80 to –2.19), FF (WMD –6.3°; 95% CI –9.9° to –2.6°), and abduction (WMD –9.4°; 95% CI –17.8° to –1.0°), but not for ER (WMD –0.6°; 95% CI –3.7° to 2.5°). Conclusion. The current literature suggests that patients with scapular notching after RTSA have significantly worse results when evaluated by the CMS, ASES score, and range of movement in flexion and abduction. Cite this article: Bone Joint J 2020;102-B(11):1438–1445


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_12 | Pages 44 - 44
23 Jun 2023
Scholz J Perka C Hipfl C
Full Access

Dual-mobility (DM) bearings are effective to mitigate dislocation in revision total hip arthroplasty (THA). However, data on its use for treating dislocation is scarce. Aim of this study was to compare DM bearings, standard bearings and constrained liner (CL) in revision THA for recurrent dislocation and to identify risk factors for re-dislocation. We reviewed 100 consecutive revision THAs performed for dislocation from 2012 and 2019. 45 hips (45%) received a DM construct, while 44 hips (44%) and 11 hips (11%) had a standard bearing and CL, respectively. Rates of re-dislocation, re-revision for dislocation and overall re-revision were compared. Radiographs were assessed for cup positioning, restoration of centre of rotation, leg length and offset. Risk factors for re-dislocation were determined by cox regression analysis. Modified Harris hip scores (mHHS) were calculated. Mean follow-up was 53 months (1 to 103). DM constructs were used more frequently in elderly patients (p=0.011) and hips with abductor deficiency (p< 0.001). The re-dislocation rate was 11.1% for DM bearings compared with 15.9% for standard bearings and 18.2% for CL (p=0.732). Revision-free survival for DM constructs was 83% (95% CI 0.77 – 0.90) compared to 75% (95% CI 0.68 – 0.82) for standard articulations and 71% (95% CI 0.56 – 0.85) for CL (p=0.455). Younger age (HR 0.91; p=0.020), lower comorbidity (HR 0.42; p=0.031), smaller heads (HR 0.80; p=0.041) and cup retention (HR 8.23; p=0.022) were associated with re-dislocation. Radiological analysis did not reveal a relationship between restoration of hip geometry and re-dislocation. mHHS significantly improved from 43.8 points to 65.7 points (p<0.001) with no differences among bearing types. Our findings suggest that DM bearings do not sufficiently prevent dislocation in revision THA for recurrent dislocation. Reconstruction of the abductor complex may play a key role to reduce the burden in these high-risk patients


The Bone & Joint Journal
Vol. 106-B, Issue 4 | Pages 352 - 358
1 Apr 2024
Wilson JM Trousdale RT Bedard NA Lewallen DG Berry DJ Abdel MP

Aims. Dislocation remains a leading cause of failure following revision total hip arthroplasty (THA). While dual-mobility (DM) bearings have been shown to mitigate this risk, options are limited when retaining or implanting an uncemented shell without modular DM options. In these circumstances, a monoblock DM cup, designed for cementing, can be cemented into an uncemented acetabular shell. The goal of this study was to describe the implant survival, complications, and radiological outcomes of this construct. Methods. We identified 64 patients (65 hips) who had a single-design cemented DM cup cemented into an uncemented acetabular shell during revision THA between 2018 and 2020 at our institution. Cups were cemented into either uncemented cups designed for liner cementing (n = 48; 74%) or retained (n = 17; 26%) acetabular components. Median outer head diameter was 42 mm. Mean age was 69 years (SD 11), mean BMI was 32 kg/m. 2. (SD 8), and 52% (n = 34) were female. Survival was assessed using Kaplan-Meier methods. Mean follow-up was two years (SD 0.97). Results. There were nine cemented DM cup revisions: three for periprosthetic joint infection, three for acetabular aseptic loosening from bone, two for dislocation, and one for a broken cup-cage construct. The two-year survivals free of aseptic DM revision and dislocation were both 92%. There were five postoperative dislocations, all in patients with prior dislocation or abductor deficiency. On radiological review, the DM cup remained well-fixed at the cemented interface in all but one case. Conclusion. While dislocation was not eliminated in this series of complex revision THAs, this technique allowed for maximization of femoral head diameter and optimization of effective acetabular component position during cementing. Of note, there was only one failure at the cemented interface. Cite this article: Bone Joint J 2024;106-B(4):352–358


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_12 | Pages 75 - 75
1 Dec 2022
Hunter J Lalone E
Full Access

Analyzing shoulder kinematics is challenging as the shoulder is comprised of a complex group of multiple highly mobile joints. Unlike at the elbow or knee which has a primary flexion/extension axis, both primary shoulder joints (glenohumeral and scapulothoracic) have a large range of motion (ROM) in all three directions. As such, there are six degrees of freedom (DoF) in the shoulder joints (three translations and three rotations), and all these parameters need to be defined to fully describe shoulder motion. Despite the importance of glenohumeral and scapulothoracic coordination, it's the glenohumeral joint that is most studied in the shoulder. Additionally, the limited research on the scapulothoracic primarily focuses on planar motion such as abduction or flexion. However, more complex motions, such as internally rotating to the back, are rarely studied despite the importance for activities of daily living. A technique for analyzing shoulder kinematics which uses 4DCT has been developed and validated and will be used to conduct analysis. The objective of this study is to characterize glenohumeral and scapulothoracic motion during active internal rotation to the back, in a healthy young population, using a novel 4DCT approach. Eight male participants over 18 with a healthy shoulder ROM were recruited. For the dynamic scan, participants performed internal rotation to the back. For this motion, the hand starts on the abdomen and is moved around the torso up the back as far as possible, unconstrained to examine variability in motion pathway. Bone models were made from the dynamic scans and registered to neutral models, from a static scan, to calculate six DoF kinematics. The resultant kinematic pathways measured over the entire motion were used to calculate the ROM for each DoF. Results indicate that anterior tilting is the most important DoF of the scapula, the participants all followed similar paths with low variation. Conversely, it appears that protraction/retraction of the scapula is not as important for internally rotating to the back; not only was the ROM the lowest, but the pathways had the highest variation between participants. Regarding glenohumeral motion, internal rotation was by far the DoF with the highest ROM, but there was also high variation in the pathways. Summation of ROM values revealed an average glenohumeral to scapulothoracic ratio of 1.8:1, closely matching the common 2:1 ratio other studies have measured during abduction. Due to the unconstrained nature of the motion, the complex relationship between the glenohumeral and scapulothoracic joints leads to high variation in kinematic pathways. The shoulder has redundant degrees of freedom, the same end position can result from different joint angles and positions. Therefore, some individuals might rely more on scapular motion while others might utilize primarily humeral motion to achieve a specific movement. More analysis needs to be done to identify if any direct correlations can be drawn between scapulothoracic and glenohumeral DoF. Analyzing the kinematics of the glenohumeral and scapulothoracic joint throughout motion will further improve understanding of shoulder mechanics and future work plans to examine differences with age


Bone & Joint Research
Vol. 8, Issue 8 | Pages 357 - 366
1 Aug 2019
Lädermann A Tay E Collin P Piotton S Chiu C Michelet A Charbonnier C

Objectives. To date, no study has considered the impact of acromial morphology on shoulder range of movement (ROM). The purpose of our study was to evaluate the effects of lateralization of the centre of rotation (COR) and neck-shaft angle (NSA) on shoulder ROM after reverse shoulder arthroplasty (RSA) in patients with different scapular morphologies. Methods. 3D computer models were constructed from CT scans of 12 patients with a critical shoulder angle (CSA) of 25°, 30°, 35°, and 40°. For each model, shoulder ROM was evaluated at a NSA of 135° and 145°, and lateralization of 0 mm, 5 mm, and 10 mm for seven standardized movements: glenohumeral abduction, adduction, forward flexion, extension, internal rotation with the arm at 90° of abduction, as well as external rotation with the arm at 10° and 90° of abduction. Results. CSA did not seem to influence ROM in any of the models, but greater lateralization achieved greater ROM for all movements in all configurations. Internal and external rotation at 90° of abduction were impossible in most configurations, except in models with a CSA of 25°. Conclusion. Postoperative ROM following RSA depends on multiple patient and surgical factors. This study, based on computer simulation, suggests that CSA has no influence on ROM after RSA, while lateralization increases ROM in all configurations. Furthermore, increasing subacromial space is important to grant sufficient rotation at 90° of abduction. In summary, increased lateralization of the COR and increased subacromial space improve ROM in all CSA configurations. Cite this article: A. Lädermann, E. Tay, P. Collin, S. Piotton, C-H Chiu, A. Michelet, C. Charbonnier. Effect of critical shoulder angle, glenoid lateralization, and humeral inclination on range of movement in reverse shoulder arthroplasty. Bone Joint Res 2019;8:378–386. DOI: 10.1302/2046-3758.88.BJR-2018-0293.R1


The Bone & Joint Journal
Vol. 106-B, Issue 5 Supple B | Pages 98 - 104
1 May 2024
Mallett KE Guarin Perez SF Taunton MJ Sierra RJ

Aims. Dual-mobility (DM) components are increasingly used to prevent and treat dislocation after total hip arthroplasty (THA). Intraprosthetic dissociation (IPD) is a rare complication of DM that is believed to have decreased with contemporary implants. This study aimed to report incidence, treatment, and outcomes of contemporary DM IPD. Methods. A total of 1,453 DM components were implanted at a single academic institution between January 2010 and December 2021: 695 in primary and 758 in revision THA. Of these, 49 presented with a dislocation of the large DM head and five presented with an IPD. At the time of closed reduction of the large DM dislocation, six additional IPDs occurred. The mean age was 64 years (SD 9.6), 54.5% were female (n = 6), and mean follow-up was 4.2 years (SD 1.8). Of the 11 IPDs, seven had a history of instability, five had abductor insufficiency, four had prior lumbar fusion, and two were conversions for failed fracture management. Results. The incidence of IPD was 0.76%. Of the 11 IPDs, ten were missed either at presentation or after attempted reduction. All ten patients with a missed IPD were discharged with a presumed reduction. The mean time from IPD to surgical treatment was three weeks (0 to 23). One patient died after IPD prior to revision. Of the ten remaining hips with IPD, the DM head was exchanged in two, four underwent acetabular revision with DM exchange, and four were revised to a constrained liner. Of these, five (50%) underwent reoperation at a mean 1.8 years (SD 0.73), including one additional acetabular revision. No patients who underwent initial acetabular revision for IPD treatment required subsequent reoperation. Conclusion. The overall rate of IPD was low at 0.76%. It is essential to identify an IPD on radiographs as the majority were missed at presentation or after iatrogenic dissociation. Surgeons should consider acetabular revision for IPD to allow conversion to a larger DM head, and take care to remove impinging structures that may increase the risk of subsequent failure. Cite this article: Bone Joint J 2024;106-B(5 Supple B):98–104


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_12 | Pages 85 - 85
1 Dec 2022
Fleet C McNeil D Trenholm JAI Johnson JA Athwal G
Full Access

Massive irreparable rotator cuff tears often lead to superior migration of the humeral head, which can markedly impair glenohumeral kinematics and function. Although treatments currently exist for treating such pathology, no clear choice exists for the middle-aged patient demographic. Therefore, a metallic subacromial implant was developed for the purpose of restoring normal glenohumeral kinematics and function. The objective of this study was to determine this implant's ability in restoring normal humeral head position. It was hypothesized that (1) the implant would restore near normal humeral head position and (2) the implant shape could be optimized to improve restoration of the normal humeral head position. A titanium implant was designed and 3D printed. It consisted of four design variables that varied in both implant thickness (5mm and 8mm) and curvature of the humeral articulating surface (high constraint and low constraint. To assess these different designs, these implants were sequentially assessed in a cadaver-based biomechanical testing protocol. Eight cadaver specimens (64 ± 13 years old) were loaded at 0, 30, and 60 degrees of glenohumeral abduction using a previously developed shoulder simulator. An 80N load was equally distributed across all three deltoid heads while a 10N load was applied to each rotator cuff muscle. Testing states included a fully intact rotator cuff state, a posterosuperior massive rotator cuff tear state (cuff deficient state), and the four implant designs. An optical tracking system (Northern Digital, Ontario, Canada) was used to record the translation of the humeral head relative to the glenoid in both superior-inferior and anterior-posterior directions. Superior-Inferior Translation. The creation of a posterosuperior massive rotator cuff tear resulted in significant superior translation of the humeral head relative to the intact cuff state (P=0.016). No significant differences were observed between each implant design and the intact cuff state as all implants decreased the superior migration of the humeral head that was observed in the cuff deficient state. On average, the 5mm low and high constraint implant models were most effective at restoring normal humeral head position to that of the intact cuff state (-1.3 ± 2.0mm, P=0.223; and −1.5 ± 2.3mm, P=0.928 respectively). Anterior-Posterior Translation. No significant differences were observed across all test states for anterior-posterior translation of the humeral head. The cuff deficient on average resulted in posterior translation of the humeral head, however, this was not statistically significant (P=0.128). Both low and high constraint implant designs were found to be most effective at restoring humeral head position to that of the intact cuff state, on average resulting in a small anterior offset (5mm high constraint: 2.0 ± 4.7mm, P=1.000; 8mm high constraint: 1.6 ± 4.9mm, P=1.000). The 5mm high constraint implant was most effective in restoring normal humeral head position in both the superior-inferior and anterior-posterior directions. The results from this study suggest the implant may be an effective treatment for restoring normal glenohumeral kinematics and function in patients with massive irreparable rotator cuff tears. Future studies are needed to address the mechanical efficiency related to arm abduction which is a significant issue related to patient outcomes


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_14 | Pages 13 - 13
1 Dec 2022
Barone A Cofano E Zappia A Natale M Gasparini G Mercurio M Familiari F
Full Access

The risk of falls in patients undergoing orthopedic procedures is particularly significant in terms of health and socioeconomic effects. The literature analyzed closely this risk following procedures performed on the lower limb, but the implications following procedures on the upper limb remain to be investigated. Interestingly, it is not clear whether the increased risk of falling in patients undergoing shoulder surgery is due to preexisting risk factors at surgery or postoperative risk factors, such as anesthesiologic effects, opioid medications used for pain control, or brace use. Only one prospective study examined gait and fall risk in patients using a shoulder abduction brace (SAB) after shoulder surgery, revealing that the brace adversely affected gait kinematics with an increase in the risk of falls. The main purpose of the study was to investigate the influence of SAB on gait parameters in patients undergoing shoulder surgery. Patients undergoing elective shoulder surgery (arthroscopic rotator cuff repair, reverse total shoulder arthroplasty, and Latarjet procedure), who used a 15° SAB in the postoperative period, were included. Conversely, patients age > 65 years old, with impaired lower extremity function (e.g., fracture sequelae, dysmorphism, severe osteo-articular pathology), central and peripheral nervous system pathologies, and cardiac/respiratory/vascular insufficiency were excluded. Participants underwent kinematic analysis at four different assessment times: preoperative (T0), 24 hours after surgery (T1), 1 week after surgery (T2), and 1 week after SAB removal (T3). The tests used for kinematic assessment were the Timed Up and Go (TUG) and the 10-meter test (10MWT), both of which examine functional mobility. Agility and balance were assessed by a TUG test (transitions from sitting to standing and vice versa, walking phase, turn-around), while gait (test time, cadence, speed, and pelvic symmetry) was evaluated by the 10MWT. Gait and functional mobility parameters during 10MWT and TUG tests were assessed using the BTS G-Walk sensor (G-Sensor 2). One-way ANOVA for repeated measures was conducted to detect the effects of SAB on gait parameters and functional mobility over time. Statistical analysis was performed with IBM®SPSS statistics software version 23.0 (SPSS Inc., Chicago, IL, USA), with the significant level set at p<0.05. 83% of the participants had surgery on the right upper limb. A main effect of time for the time of execution (duration) (p=0.01, η2=0.148), speed (p<0.01, η2=0.136), cadence (p<0.01, η2=0.129) and propulsion-right (R) (p<0.05, η2=0.105) and left (L) (p<0.01, η2=0.155) in the 10MWT was found. In the 10MWT, the running time at T1 (9.6±1.6s) was found to be significantly longer than at T2 (9.1±1.3s, p<0.05) and at T3 (9.0±1.3s, p=0.02). Cadence at T1 (109.7±10.9steps/min) was significantly lower than at T2 (114.3 ±9.3steps/min, p<0.01) and T3 (114.3±9.3steps/min, p=0.02). Velocity at T1 (1.1±0.31m/s) was significantly lower than at T2 (1.2± 0.21m/s, p<0.05). No difference was found in the pelvis symmetry index. No significant differences were found during the TUG test except for the final rotation phase with T2 value significantly greater than T3 (1.6±0.4s vs 1.4±0.3s, p<0.05). No statistically significant differences were found between T0 and T2 and between T0 and T3 in any of the parameters analyzed. Propulsion-R was significantly higher at T3 than T1 (p<0.01), whereas propulsion-L was significantly lower at T1 than T0 (p<0.05) and significantly higher at T2 and T3 than T1 (p<0.01). Specifically, the final turning phase was significantly higher at T2 than T3 (p<0.01); no significant differences were found for the duration, sit to stand, mid-turning and stand to sit phases. The results demonstrated that the use of the abduction brace affects functional mobility 24 hours after shoulder surgery but no effects were reported at longer term observations


The Bone & Joint Journal
Vol. 101-B, Issue 11 | Pages 1459 - 1463
1 Nov 2019
Enishi T Yagi H Higuchi T Takeuchi M Sato R Yoshioka S Nakamura M Nakano S

Aims. Rotational acetabular osteotomy (RAO) is an effective joint-preserving surgical treatment for acetabular dysplasia. The purpose of this study was to investigate changes in muscle strength, gait speed, and clinical outcome in the operated hip after RAO over a one-year period using a standard protocol for rehabilitation. Patients and Methods. A total of 57 patients underwent RAO for acetabular dysplasia. Changes in muscle strength of the operated hip, 10 m gait speed, Japanese Orthopaedic Association (JOA) hip score, and factors correlated with hip muscle strength after RAO were retrospectively analyzed. Results. Three months postoperatively, the strength of the operated hip in flexion and abduction and gait speed had decreased from their preoperative levels. After six months, the strength of flexion and abduction had recovered to their preoperative level, as had gait speed. At one-year follow-up, significant improvements were seen in the strength of hip abduction and gait speed, but muscle strength in hip flexion remained at the preoperative level. The mean JOA score for hip function was 91.4 (51 to 100)) at one-year follow-up. Body mass index (BMI) showed a negative correlation with both strength of hip flexion (r = -0.4203) and abduction (r = -0.4589) one year after RAO. Although weak negative correlations were detected between strength of hip flexion one year after surgery and age (r = -0.2755) and centre-edge (CE) angle (r = -0.2989), no correlation was found between the strength of abduction and age and radiological evaluations of CE angle and acetabular roof obliquity (ARO). Conclusion. Hip muscle strength and gait speed had recovered to their preoperative levels six months after RAO. The clinical outcome at one year was excellent, although the strength of hip flexion did not improve to the same degree as that of hip abduction and gait speed. A higher BMI may result in poorer recovery of hip muscle strength after RAO. Radiologically, acetabular coverage did not affect the recovery of hip muscle strength at one year’s follow-up. A more intensive rehabilitation programme may improve this. Cite this article: Bone Joint J 2019;101-B:1459–1463


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_2 | Pages 63 - 63
2 Jan 2024
Winkler T
Full Access

The HIPGEN study funded under EU Horizon 2020 (Grant 7792939) has the aim to investigate the potential of the first regenerative cell therapy for the improvement of recovery after muscle injury in hip fracture patients. For this aim we intramuscularly injected placental derived mesenchymal stromal cells during hip fracture arthroplasty. Despite not having reached the primary endpoint, which was the Short Physical Performance Battery, we could observe an increase in abductor muscle strength and a faster return to balance looking at symmetry in insole measurements during follow up


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_12 | Pages 31 - 31
1 Oct 2019
Whiteside LA
Full Access

Introduction. The results of repair and reconstruction of lesions found in the abductor muscles and tendons during posterior approach to primary total hip arthroplasty (THA) were reported in 2018. During the course of this series it became apparent that the extent of damage in the abductor tendons and muscles usually was obscured by the hypertrophic greater trochanteric bursa, especially the deep layer adherent to the greater trochanter and abductor muscles. The purpose of this study was to evaluate the surgeon's ability to see these lesions during standard posterior approach, and also to describe the dissection necessary to fully expose them. Patients and Methods. A total of 525 patients (525 hips) underwent primary THA through posterior approach between 2009 and 2013. Fifty-four patients had mild chronic damage to the tendon. Forty-one patients had severe damage with major avulsion of the gluteus medius and minimus muscles. Results. None of the hips with normal abductor muscle structure had a dense trochanteric bursa to obscure the abductor attachment to bone, but in 35 hips (85.3%) with significant abductor tendon avulsion, the lesions in the tendons were hidden from view until the greater trochanteric bursa was dissected. Splitting the deep layer of the trochanteric bursa in line with the fibers of the abductor muscles was necessary to reveal avulsion of the tendons from the edge of the greater trochanter. Only six hips (14.6%) had abductor tendon avulsion from the greater trochanter that could be seen without removing the trochanteric bursa tissue. Conclusion. The posterior approach offered excellent exposure of the abductor mechanism during primary THA, but the avulsion defects in the gluteus medius and minimus muscles remained obscured until the outer layer of the greater trochanteric bursa was completely removed and the deep fibrous layer was dissected adequately to expose the tendon attachment to bone. For any tables or figures, please contact the authors directly


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_2 | Pages 8 - 8
10 Feb 2023
Brennan A Blackburn J Thompson J Field J
Full Access

Thumb carpometacarpal joint (CMCJ) arthritis is a common and debilitating condition. The mainstay of surgical management is Trapeziectomy. Concerns about possible functional implications of collapse of the metacarpal into the arthroplasty space as well as the potential for scaphometacarpal led to the development of techniques to try and prevent this. The purpose of this study was to investigate if there were any significant differences in the long-term outcomes of patients who participated in a randomized trial of trapeziectomy alone compared with trapeziectomy with ligament reconstruction and tendon interposition (LRTI). Sixty-five patients participated in our original trial, the 1 year findings of which were published in 2007. These patients were invited for a follow-up visit at a mean of 17 years (range 15–20) postoperatively. Twenty-eight patients attended, who had 34 operations, 14 trapeziectomy alone and 20 with LRTI. Patients were asked to complete a visual analogue scale (VAS) for satisfaction with the outcome of their procedure, rated on a scale from 0 (most dissatisfied) to 100 (most satisfied). They also completed the short version of the Disabilities of the Arm, Shoulder and Hand Score (QuickDASH) at their appointment. They underwent a functional assessment with a hand therapist and had a radiograph of the thumb. There were no statistically significant differences between the two groups in terms of satisfaction with surgery or functional outcomes, with most measurements showing minimal or no differences in means between the two groups. There was no difference in the space between the metacarpal and scaphoid on radiograph. Radial abduction was the only parameter that was significantly greater in the patients with simple trapeziectomy (median 79°) compared with trapeziectomy with LRTI (median 71°) (p = 0.04). Even at 17 years there is no significant benefit of LRTI over trapeziectomy alone for thumb carpometacarpal joint osteoarthritis


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_8 | Pages 99 - 99
1 May 2019
Whiteside L
Full Access

Complete or nearly complete disruption of the attachment of the gluteus is seen in 10–20% of cases at the time of THA. Special attention is needed to identify the lesion at the time of surgery because the avulsion often is visible only after a thickened hypertrophic trochanteric bursa is removed. From 1/1/09 to 12/31/13, 525 primary hip replacements were performed by a single surgeon. After all total hip components were implanted, the greater trochanteric bursa was removed, and the gluteus medius and minimus attachments to the greater trochanter were visualised and palpated. Ninety-five hips (95 patients) were found to have damage to the muscle attachments to bone. Fifty-four hips had mild damage consisting of splits in the tendon, but no frank avulsion of abductor tendon from their bone attachments. None of these cases had severe atrophy of the abductor muscles, but all had partial fatty infiltration. All hips with this mild lesion had repair of the tendons with #5 Ticron sutures to repair the tendon bundles together, and drill holes through bone to anchor the repair to the greater trochanter. Forty-one hips had severe damage with complete or nearly complete avulsion of the gluteus medius and minimus muscles from their attachments to the greater trochanter. Thirty-five of these hips had partial fatty infiltration of the abductor muscles, but all responded to electrical stimulation. The surface of the greater trochanter was denuded of soft tissue with a rongeur, the muscles were repaired with five-seven #5 Ticron mattress sutures passed through drill holes in the greater trochanter, and a gluteus maximus flap was transferred to the posterior third of the greater trochanter and sutured under the vastus lateralis. Six hips had complete detachment of the gluteus medius and minimus muscles, severe atrophy of the muscles, and poor response of the muscles to electrical stimulation. The gluteus medius and minimus muscles were sutured to the greater trochanter, and gluteus maximus flap was transferred as in the group with functioning gluteus medius and minimus muscles. Postoperatively, patients were instructed to protect the hip for 8 weeks, then abductor exercises were started. The normal hips all had negative Trendelenburg tests at 2 and 5 years postoperative with mild lateral hip pain reported by 11 patients at 2 years, and 12 patients at 5 years. In the group of 54 with mild abductor tendon damage that were treated with simple repair, positive Trendelenburg test was found in 5 hips at 2 years and in 8 hips at 5 years. Lateral hip pain was reported in 7 hips at 2 years, and in 22 at 5 years. In the group of 35 hips with severe avulsion but good muscle tissue, who underwent repair with gluteus maximus flap transfer, all had good abduction against gravity and negative Trendelenburg tests at 2 and 5 years postoperative, and none had lateral hip pain. Of the 6 hips with complete avulsion and poor muscle who underwent abductor muscle repair and gluteus maximus flap transfer, all had weak abduction against gravity, mildly positive Trendelenburg sign, and mild lateral hip pain at 2 and 5 years postoperative. Abductor avulsion is uncommon but not rare, and is detected during THA only by direct examination of the tendon and removal of the trochanteric bursa. Simple repair of mild abductor tendon damage did not prevent progressive abductor weakness in some hips; and the increase in number of patients with lateral hip pain from 2 to 5 years suggests progressive deterioration. Augmentation of the repair with a gluteus maximus flap appears to provide a stable reconstruction of the abductor muscles, and seemed to restore abductor function in the hips with functioning muscles


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_11 | Pages 4 - 4
1 Nov 2022
Adapa A Shetty S Kumar A Pai S
Full Access

Abstract. Background. Fractures Proximal humerus account for nearly 10 % of geriatric fractures. The treatment options varies. There is no consensus regarding the optimal treatment, with almost all modalities giving functionally poor outcomes. Hence literature recommends conservative management over surgical options. MULTILOC nail with its design seems to be a promising tool in treating these fractures. We hereby report our early experience in the treatment of 37 elderly patients. Objectives. To evaluate the radiological outcome with regards to union, collapse, screw back out/cut through, implant failures, Greater tuberosity migration. To evaluate the functional outcome at the end of 6 months using Constant score. Study Design & Methods. All patients aged >65 years who underwent surgery for 3,4-part fracture proximal humerus using the MULTILOC nail were included in the study after consent. Pre – existing rotator cuff disease were excluded. Within the time frame, a total of 39 patients underwent the said surgery. 2 patients were lost to follow up. All the measurements were taken at the end of 6 months and results tabulated and analysed. Results. Union was achieved in all the 37 patients. There were no varus collapse or screw backout/cut through seen in any of the patients. There was Greater tuberosity migration in 1 patient who underwent revision surgery at 6 weeks. All the patients got a minimum of 70 degrees of abduction and forward flexion. We had 29 excellent, 6 good, 2 fair and none poor results as per Constant scoring system. Study done in Tejasvini Hospital & SSIOT Mangaluru India


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_11 | Pages 5 - 5
4 Jun 2024
Ubillus H Mattos I Campos G Soares S Kennedy J
Full Access

Introduction. Tibial nerve anatomy has not been studied profoundly in comparison to Tarsal Tunnel Syndrome (TTS). Assuming symptoms are caused by an anatomical variant or mechanical cause regarding the tibial nerve, it is essential to investigate the anatomy of this structure taking in consideration that surgical and conservative treatments have shown poor results. Methods. 40 lower-leg specimens were obtained. Dissection started 20 centimeters proximal to the Dellon-McKinnon (DM) line towards the medial aspect of the naviculo-cuneiform joint distally. Anteriorly, dissection began at the tibio-talar medial gutter until the medial aspect of the Achilles tendon posteriorly. The plantar aspect extended from medial to lateral within the parameters previously described, ending at the level of the second metatarsal. Results. The flexor retinaculum had a denser consistency in 22.5% of the cases and the average length was 51.9 mm. The flexor retinaculum as an independent structure was found absent and 77.2% of cases as undistinguished extension of the crural fascia. The lateral plantar nerver (LPN) and abductor digiti minimi (ADM) nerve shared same origin in 80% of cases, 34.5% bifurcated proximal to the DM line, 31.2% distally and 34.3% at the same level. The medial calcaneal nerve (MCN) emerged proximal to the DM line in 100% of specimens. The medial plantar nerve (MPN) has its origin proximal to the DM line in 95% of cases. Conclusion. The flexor retinaculum is an extension of the crural fascia and not an independent structure. The LPN and ADM have the same origin in most cases and this presents as an important finding that must be studied in detail for clinical correlations between the motor and sensatory affections of the ADM and LPN respectively. Finally, the branches of the MCN and MPN are the most constant in their distribution and proximal origin in relation to the Dellon-McKinnon line


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_16 | Pages 72 - 72
19 Aug 2024
Chen X
Full Access

Sequelae of Legg-Calve -Perthes disease (LCPD) and treatment of developmental dysplasia of the hip (DDH) can present a coxa breva or coxa magna deformity, sometimes associated with coxa vara. This unique deformity decreases the efficiency of the abductor mechanism, causing a Trendelenburg gait and hip pain, leg length discrepancy and leads to intra- and extra-articular impingement, and eventually osteoarthritis. Several surgical techniques have been advocated to treat this kind deformity, such as great trochanter transfer, relative femoral neck lengthening. We evaluated primary results of true femoral neck-lengthening osteotomy (TFNLO) in combination with periacetabular osteotomy (PAO) for treatment of Coxa Breva through surgical hip dislocation (SHD). Fourteen patients with Coxa Breva received true femoral neck lengthening osteotomy in combination of PAO through SHD between March 2020 and October 2023. Ten patients with minimum 1 year followed-up were retrospectively reviewed clinically and radiographically. Eight patients had Perthes disease, 2 had DDH received closed reduction and fixation during childhood. The mean age at surgery was 16 years (range, 12 to 31 years). Clinical findings, radiographic analyses including the change in horizontal femoral offset and the leg length discrepancy as well as complications were assessed. Horizontal femoral offset improved 19.5mm(6–28mm). Limb length increase 16.8mm(11–30mm). Mean HHS increased from 80.6(66–91) to 91.8(88–96). Complication: screw broken in 1(no need operation). Asymptomatic fibrous union of the great trochanter was found in 1. No infection and joint space narrow as well as nerve palsy happened. TFNLO combined with PAO can be effective for the treatment of patients with Coxa breva. But long term follow up is warranted


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_3 | Pages 83 - 83
23 Feb 2023
Rossignol SL Boekel P Grant A Doma K Morse L
Full Access

Currently, the consensus regarding subscapularis tendon repair during a reverse total shoulder arthroplasty (rTSA) is to do so if it is possible. Repair is thought to decrease the risk of dislocation and improve internal rotation but may also increase stiffness and improvement in internal rotation may be of subclinical benefit. Aim is to retrospectively evaluate the outcomes of rTSA, with or without a subscapularis tendon repair. We completed a retrospective review of 51 participants (25 without and 26 with subscapularis repair) who received rTSR by a single-surgeon using a single-implant. Three patient reported outcome measures (PROM) were assessed pre-operatively and post-operative at twelve months, as well as range of movement (ROM) and plain radiographs. Statistical analysis utilized unpaired t tests for parametric variables and Mann-Whitney U test for nonparametric variables. External Rotation ROM pre-operatively was the only variable with a significance difference (p=0.02) with the subscapularis tendon repaired group having a greater range. Pre- and post-operative abduction (p=0.72 & 0.58), forward flexion (p=0.67 & 0.34), ASES (p=0.0.06 & 0.78), Oxford (p=0.0.27 & 0.73) and post-operative external rotation (p=0.17). Greater external rotation ROM pre-operatively may be indicative of the ability to repair the subscapularis tendon intra-operatively. However, repair does not seem to improve clinical outcome at 12 months. There was no difference of the PROMs and AROMs between the subscapularis repaired and not repaired groups for any of the variables at the pre-operative or 12 month post operative with the exception of the external rotation ROM pre-operatively. We can conclude that from PROM or AROM perspective there is no difference if the tendon is repaired or not in a rTSR and indeed the patients without the repair may have improved outcomes at 12 months


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_13 | Pages 74 - 74
7 Aug 2023
Alabdullah M Liu A Xie S
Full Access

Abstract. Rehabilitation exercise is critical for patients’ recovery after knee injury or post-surgery. Unfortunately, adherence to exercise is low due to a lack of positive feedback and poor self-motivation. Therefore, it is crucial to monitor their progress and provide supervision. Inertial measurement unit (IMUs) based sensing technology can provide remote patient monitoring functions. However, most current solutions only measure the range of knee motion in one degree of freedom. The current IMUs estimate the orientation-angle based on the integrated raw data, which might lack accuracy in measuring knee motion. This study aims to develop an IMU-based sensing system using the absolute measured orientation-angle to provide more accurate comprehensive monitoring by measuring the knee rotational angles. An IMU sensing system monitoring the knee joint angles, flexion/extension (FE), adduction/abduction (AA), and internal/external (IE) was developed. The accuracy and reliability of FE measurements were validated in human participants during squat exercise using measures including root mean square error (RMSE) and correlation coefficient. The RMSE of the three knee angles (FE, AA, and IE) were 0.82°, 0.26°, and 0.11°, which are acceptable for assessing knee motion. The FE measurement was validated in human participants and showed excellent accuracy (correlation coefficient of 0.99°). Further validation of AA and IE in human participants is underway. The sensing system showed the capability to estimate three knee rotation angles (FE, AA, and IE). It showed the potential to provide comprehensive continuous monitoring for knee rehabilitation exercises, which can also be used as a clinical assessment tool


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_7 | Pages 148 - 148
4 Apr 2023
Jørgensen P Kaptein B Søballe K Jakobsen S Stilling M
Full Access

Dual mobility hip arthroplasty utilizes a freely rotating polyethylene liner to protect against dislocation. As liner motion has not been confirmed in vivo, we investigated the liner kinematics in vivo using dynamic radiostereometry. 16 patients with Anatomical Dual Mobility acetabular components were included. Markers were implanted in the liners using a drill guide. Static RSA recordings and patient reported outcome measures were obtained at post-op and 1-year follow-up. Dynamic RSA recordings were obtained at 1-year follow-up during a passive hip movement: abduction/external rotation, adduction/internal rotation (modified FABER-FADIR), to end-range and at 45° hip flexion. Liner- and neck movements were described as anteversion, inclination and rotation. Liner movement during modified FABER-FADIR was detected in 12 of 16 patients. Median (range) absolute liner movements were: anteversion 10° (5–20), inclination 6° (2–12), and rotation 11° (5–48) relative to the cup. Median absolute changes in the resulting liner/neck angle (small articulation) was 28° (12–46) and liner/cup angle (larger articulation) was 6° (4–21). Static RSA showed changes in median (range) liner anteversion from 7° (-12–23) postoperatively to 10° (-3–16) at 1-year follow-up and inclination from 42 (35–66) postoperatively to 59 (46–80) at 1-year follow-up. Liner/neck contact was associated with high initial liner anteversion (p=0.01). The polyethylene liner moves over time. One year after surgery the liner can move with or without liner/neck contact. The majority of movement is in the smaller articulation between head and liner


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_2 | Pages 3 - 3
10 Feb 2023
Sundaram A Woods J Clifton L Alt V Clark R Carey Smith R
Full Access

Complex acetabular reconstruction for oncology and bone loss are challenging for surgeons due to their often hostile biological and mechanical environments. Titrating concentrations of silver ions on implants and alternative modes of delivery allow surgeons to exploit anti-infective properties without compromising bone on growth and thus providing a long-term stable fixation. We present a case series of 12 custom acetabular tri-flange and custom hemipelvis reconstructions (Ossis, Christchurch, New Zealand), with an ultrathin plasma coating of silver particles embedded between layers of siloxane (BioGate HyProtect™, Nuremberg, Germany). At the time of reporting no implant has been revised and no patient has required a hospital admission or debridement for a deep surgical site infection. Routine follow up x-rays were reviewed and found 2 cases with loosening, both at their respective anterior fixation. Radiographs of both cases show remodelling at the ilium indicative of stable fixation posteriorly. Both patients remain asymptomatic. 3 patients were readmitted for dislocations, 1 of whom had 5 dislocations within 3 weeks post-operatively and was immobilised in an abduction brace to address a lack of muscle tone and has not had a revision of their components. Utilising navigation with meticulous implant design and construction; augmented with an ultrathin plasma coating of silver particles embedded between layers of siloxane with controlled and long-term generation of silver ion diffusion has led to outstanding outcomes in this series of 12 custom acetabular and hemipelvis reconstructions. No patients were revised for infection and no patients show signs of failure of bone on growth and incorporation. Hip instability remains a problem in these challenging mechanical environments and we continue to reassess our approach to this multifaceted problem


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_4 | Pages 2 - 2
8 Feb 2024
Dixon JE Rankin IA Sciberras N Khan LAK Barker SL Cairns DA Kumar K
Full Access

In recent years, use of anatomic stemless total shoulder arthroplasty (AsTSA) has increased. Despite evidence to suggest good mid-term results at 2-year follow-up there is a paucity of evidence for longer term follow-up. This study aimed to investigate outcomes at a minimum of 5 years post-operatively following primary AsTSA. This study is a retrospective case series of all patients who underwent a Mathys Affinis AsTSA from July 2010 (first case) to August 2018 (to allow minimum 5-year follow-up). Clinical outcomes included revision rate, range of motion and patient reported outcomes (Oxford Shoulder Score and Numerical Satisfaction Score). Radiological outcome was assessment of radiolucent lines for Lazarus grading. A total of 105 stemless TSAs were implanted. Five patients underwent revision (4.8%). Seventy-five AsTSA's were included in the final study for analysis of 5-year outcomes. Median follow-up time was 6.1 years. Median age was 69 years old and 81% were female. Oxford shoulder score showed a range of 18 to 48, with a median score of 47. Satisfied or very Satisfied was selected in 94.37%. Median range of motion assessments showed forward elevation 160°, abduction 150°, external rotation 40°, and mode internal rotation was to the lumbar spine. No glenoid lucency was present in 79.7%. There were 9.5% with Lazarus Grade 1 lucency, 5.4% with Lazarus Grade 2, and 5.4% Lazarus Grade 3. No humeral lucency was observed. This cohort study demonstrates promising clinical and radiological outcomes for the Mathys Affinis Stemless TSA at minimum 5 years post-operatively


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_7 | Pages 140 - 140
4 Apr 2023
Fry M Ren W Bou-Akl T Wu B Cizmic Z Markel D
Full Access

Extensor mechanism and abductor reconstructions in total joint arthroplasty are problematic. Growing tendon into a metallic implant would have great reconstructive advantages. With the introduction of porous metal implants, it was hoped that tendons could be directly attached to implants. However, the effects of the porous metal structure on tissue growth and pore penetration is unknown. In this rat model, we investigated the effect of pore size on tendon repair fixation using printed titanium implants with differing pore sizes. There were four groups of six Sprague Dawley rats (n = 28) plus control (n=4). Implants had pore sizes of 400µm (n=8), 700µm (n=8), and 1000µm (n=8). An Achilles tendon defect was created, and the implant positioned and sutured between the cut ends. Harvest occurred at 12-weeks. Half the specimens underwent tensile load to failure testing, the other half fixed and processed for hard tissue analysis. Average load to failure was 72.6N for controls (SD 10.04), 29.95N for 400µm (SD 17.95), 55.08N for 700µm (SD 13.47), and 63.08N for 1000µm (SD 1.87). The load to failure was generally better in the larger pore sizes. Histological evaluation showed that there was fibrous tendon tissue within and around the implant material, with collagen fibers organized in bundles. This increases as the pore diameter increases. Printing titanium implants allows for precise determination of pore size and structure. Our results showed that tendon repair utilizing implants with 700µm and 1000µm pores exhibited similar load to failure as controls. Using a defined pore structure at the attachment points of tendons to implants may allow predictable tendon to implant reconstruction at the time of revision arthroplasty


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_15 | Pages 29 - 29
7 Aug 2024
Hunter R Beattie M Zubala A Gorely T
Full Access

Background. Mobile apps have shown promise in helping people to self-manage conditions like chronic low back pain (CLBP). However, it is unclear who benefits most, why, and under what circumstances. This limits our understanding of how to maximize the potential of mobile app technology. Aim. This study aimed to test and refine programme theories about how mobile apps support people to self-manage CLBP in a real-world setting. The theories were based on a previously published realist review. Methods. A realist evaluation was conducted using one-to-one realist interviews by telephone with participants who had used the Curable app to self-manage their CLBP for three months. The interviews were guided by programme theories from the realist review. Analysis of the interviews used abductive and retroductive logic to create chains of inferences, which were then developed into context-mechanism-outcome configurations (CMOCs). These CMOCs offered causal explanations about who might benefit from a mobile app to self-manage CLBP, why and in what circumstances. Results. Ten interviews were conducted (nine with people with CLBP who trialled the app and one with a founding member of Curable LLC). Twenty CMOCs were created that identified key mechanisms such as agency, control and reassurance that interact with contextual factors such as acceptance, internal capacity, and a biopsychosocial approach to pain management. These factors influence whether a person with CLBP will benefit from a mobile app for self-management. Conclusions. Twenty CMOCs were created to support three programme theories centering around concepts of empowerment, burden of care, and timing. Conflicts of interest. None. Sources of funding. R Hunter's work was supported by the Inverness and Highland City-Region Deal Studentship Award [2018]. Presented at: 13th Congress of the European Pain Federation (EFIC), September 2023, Budapest, Hungary


There is still no clear consensus regarding which cup position might provide better functional performance for developmental dysplasia of the hip (DDH). This study aimed to evaluated the feasibility and efficacy of acetabular mirroring reconstruction for DDH in total hip arthroplasty (THA). The study reviewed 96 patients (96 hips) with unilateral Crowe type-II/III DDH undergoing either visualized navigation-assisted mirroring reconstruction with augment according to the rotation center and biomechanical structure of the contralateral normal hips (Mirroring group, 51 hips) or high hip center reconstruction (HHC group, 45 hips) in THA from 2020 to 2023. The functional and radiographic results were analyzed between the groups during a mean follow-up period of 27.5 and 28.9 months (a minimum follow-up of 12 months). The Harris hip score at the last follow-up significantly improved in both groups, while it was significantly higher in the mirroring group (P<0.001). In the HHC group, the rotation center height and greater trochanter height were significantly increased in the affected hip (P<0.001; P<0.001) and the abductor lever arm was significantly decreased in the affected hip compared to that in the contralateral normal hip (P<0.001), whereas in the mirroring group no significant statistical differences were observed between two sides. The limping occurred in 7 patients (13.7%) in the mirroring group and 14 patients (31.1%) in the HHC group (P=0.040). A multiple logistic regression demonstrated mirroring reconstruction could reduce the incidence of postoperative limping (P=0.020). Both mirroring and HHC reconstruction could improve the functional performance of THA, whereas mirroring reconstruction could offer superior biomechanical results and gait improvement as compared with HHC reconstruction, meeting the higher requirements of functional recovery


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_12 | Pages 46 - 46
23 Jun 2023
Mallett K Guarin S Sierra RJ
Full Access

Dual mobility (DM) components are increasingly used to prevent and treat dislocation after total hip arthroplasty (THA). Intraprosthetic dissociation (IPD) is a known rare complication of these implants and has reportedly decreased with modern implants. The purpose of this paper is to report the diagnosis and treatment of modern DM IPD. 1453 DM components were implanted between 2010 and 2021. 695 in primary and 758 in revision THA. 49 hips sustained a dislocation of the large head and 5 sustained an IPD at presentation. 6 additional IPD occurred at the time of reduction of large head. The average age was 64, 54% were female and the mean follow-up was three years. Of the 11 IPD, 8 had a history of instability, 5 had abductor insufficiency, 4 had prior lumbar fusion, and 3 were conversions from fracture. The overall IPD incidence was 0.76%. Ten of the 11 DM IPD were missed at initial presentation or at the time of reduction, and all were discharged with presumed reduction. The mean time from IPD to surgical treatment was 3 weeks. One patient died with an IPD at 5 months. A DM head was reimplanted in six, two underwent revision of the acetabular component with exchange of DM head, and four were revised to a constrained liner. The re-revision rate was 55% at a mean 1.8 years. None of the patients who underwent cup revision required subsequent re-revision while half of the constrained liners and exchange of DM heads required re-revision. The overall rate of DM dislocation or IPD is low. It is critical to identify an IPD on radiographs as it was almost universally missed at presentation or when it occurred iatrogenically. For patients presenting with IPD, the surgeon should consider acetabular revision and conversion to a constrained liner or a larger DM, with special attention to removing impinging structures that could increase the risk of re-dislocation


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_16 | Pages 57 - 57
19 Aug 2024
Jones SA Davies O
Full Access

Dislocation following revision THA remains a leading cause of failure. Integrity of the abductor muscles is a major contributor to stability. Large diameter heads (LDH), Dual Mobility (DM) and Constrained Acetabular Liners (CAL) are enhanced stability options but the indication for these choices remains unclear. We assessed an algorithm based on Gluteus Medius (GM) deficiency to determine bearing selection. Default choice with no GM damage was a LDH. GM deficiency with posterior muscle intact received DM and CAL for GM complete deficiency with loss of posterior muscle. Consecutive revision THA series followed to determine dislocation, all-cause re-revision and Oxford Hip Score (OHS). 311 revision THA with mean age 70 years (32–95). At a mean follow-up of 4.8 years overall dislocation rate 4.1% (95%CI 2.4–7.0) and survivorship free of re-revision 94.2% (95%CI 96.3–91.0). Outcomes:. Group 1 - LDH (36 & 40mm) n=164 / 4 dislocations / 7 re-revisions. Group 2 - DM n=73 / 3 dislocations / 4 re-revisions. Group 3 - CAL n=58 / 5 dislocations / 7 re-revisions. Group 4 - Other (28 & 32mm) n=16 / 1 dislocation / no re-revisions. Mean pre-op OHS: 19.6 (2–47) and mean post-op OHS: 33.9 (4–48). Kaplan-Meier analysis at 60 months dislocation-free survival was 96.1% (95% CI: 93.0–97.8). There was no difference between survival distributions comparing bearing choice (p=0.46). Decision making tools to guide selection are limited and in addition soft tissue deficiency has been poorly defined. The posterior vertical fibres of GM have the greatest lateral stabiliser effect on the hip. The algorithm we have used clearly defined indication & implant selection. We believe our outcomes support the use of an enhanced stability bearing selection algorithm


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_2 | Pages 7 - 7
2 Jan 2024
Raes L Peiffer M Kvarda P Leenders T Audenaert EA Burssens A
Full Access

A medializing calcaneal osteotomy (MCO) is one of the key inframalleolar osteotomies to correct progressive collapsing foot deformity (PCFD). While many studies were able to determine the hind- and midfoot alignment after PCFD correction, the subtalar joint remained obscured by superposition on plain radiography. Therefore, we aimed to perform a 3D measurement assessment of the hind- and subtalar joint alignment pre- compared to post-operatively using weightbearing CT (WBCT) imaging. Fifteen patients with a mean age of 44,3 years (range 17-65yrs) were retrospectively analyzed in a pre-post study design. Inclusion criteria consisted of PCFD deformity correct by MCO and imaged by WBCT. Exclusion criteria were patients who had concomitant midfoot fusions or hindfoot coalitions. Image data were used to generate 3D models and compute the hindfoot - and talocalcaneal angle as well as distance maps. Pre-operative radiographic parameters of the hindfoot and subtalar joint alignment improved significantly relative to the post-operative position (HA, MA. Sa. , and MA. Co. ). The post-operative talus showed significant inversion, abduction, and dorsiflexion of the talus (2.79° ±1.72, 1.32° ±1.98, 2.11°±1.47) compared to the pre-operative position. The talus shifted significantly different from 0 in the posterior and superior direction (0.62mm ±0.52 and 0.35mm ±0.32). The distance between the talus and calcaneum at the sinus tarsi increased significantly (0.64mm ±0.44). This study found pre-dominantly changes in the sagittal, axial and coronal plane alignment of the subtalar joint, which corresponded to a decompression of the sinus tarsi. These findings demonstrate the amount of alternation in the subtalar joint alignment that can be expected after MCO. However, further studies are needed to determine at what stage a calcaneal lengthening osteotomy or corrective arthrodesis is indicated to obtain a higher degree of subtalar joint alignment correction


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_3 | Pages 49 - 49
1 Mar 2021
Pasic N Degen R Burkhart T
Full Access

Hip arthroscopy rates continue to increase. As a result, there is growing interest in capsular management techniques. Without careful preservation and surgical techniques, failure of the repair result in capsular deficiency, contributing to iatrogenic instability and persistent post-operative pain. In this setting, capsular reconstruction may be indicated, however there is a paucity of objective evidence comparing surgical techniques to identify the optimal method. Therefore, the objective of this study was to evaluate the biomechanical effect of capsulectomy and two different capsular reconstruction techniques (iliotibial band [ITB] autograft and Achilles tendon allograft) on hip joint kinematics in both rotation and abduction/adduction. Eight paired fresh-frozen hemi-pelvises were dissected of all overlying soft tissue, with the exception of the hip joint capsule. The femur was potted and attached to a load cell connected to a joint-motion simulator, while the pelvis was secured to a custom-designed fixture allowing adjustment of the flexion-extension arc. Optotrak markers were rigidly attached to the femur and pelvis to track motion of the femoral head with respect to the acetabulum. Pairs were divided into ITB or Achilles capsular reconstruction. After specimen preparation, three conditions were tested: (1) intact, (2) after capsulectomy, and (3) capsular reconstruction (ITB or Achilles). All conditions were tested in 0°, 45°, and 90° of flexion. Internal rotation (IR) and external rotation (ER) as well abduction (ABD) and adduction (ADD) moments of 3 N·m were applied to the femur via the load cell at each position. Rotational range of motion and joint kinematics were recorded. When a rotational force was applied the total magnitude of internal/external rotation was significantly affected by the condition of the capsule, independent of the type of reconstruction that was performed (p=0.001). The internal/external rotation increased significantly by approximately 8° following the capsulectomy (p<0.001) and this was not resolved by either of the reconstructions; there remained a significant difference between the intact and reconstruction conditions (p=0.035). The total anterior/posterior translation was significantly affected by the condition of the capsule (p=0.034). There was a significant increase from 6.7 (6.0) mm when the capsule was intact to 9.0 (6.7) mm following the capsulectomy (p=0.002). Both of the reconstructions (8.6 [5.6] mm) reduced the anterior/posterior translation closer to the intact state. There was no difference between the two reconstructions. When an abduction/adduction force was applied there was a significant increase in the medial-lateral translation between the intact and capsulectomy states (p=0.047). Across all three flexion angles the integrity of the native hip capsule played a significant role in rotational stability, where capsulectomy significantly increased rotational ROM. Hip capsule reconstruction did not restore rotational stability and also increased rotational ROM compared to the intact state a statistically significant amount. However, hip capsule reconstruction restored coronal and sagittal plane stability to approach that of the native hip. There was no difference in stability between ITB and Achilles reconstructions across all testing conditions


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_3 | Pages 38 - 38
1 Mar 2021
Tavakoli A Faber K Langohr G
Full Access

Total shoulder arthroplasty (TSA) is an effective treatment for end-stage glenohumeral arthritis. The use of high modulus uncemented stems causes stress shielding and induces bone resorption of up to 63% of patients following TSA. Shorter length stems with smaller overall dimensions have been studied to reduce stress shielding, however the effect of humeral short stem varus-valgus positioning on bone stress is not known. The purpose of this study was to quantify the effect of humeral short stem varus-valgus angulation on bone stresses after TSA. Three dimensional models of eight male cadaveric humeri (mean±SD age:68±6 years) were created from computed tomography data using MIMICS (Materialise, Belgium). Separate cortical and trabecular bone sections were created, and the resulting bone models were virtually reconstructed three times by an orthopaedic surgeon using an optimally sized short stem humeral implant (Exactech Preserve) that was placed directly in the center of the humeral canal (STD), as well as rotated varus (VAR) or valgus (VAL) until it was contacting the cortex. Bone was meshed using a custom technique which produced identical bone meshes permitting the direct element-to-element comparison of bone stress. Cortical bone was assigned an elastic modulus of 20 GPa and a Poisson's ratio of 0.3. Trabecular bone was assigned varying stiffness based on CT attenuation. A joint reaction force was then applied to the intact and reconstructed humeri representing 45˚ and 75˚ of abduction. Changes in bone stress, as well as the expected bone response based on change in strain energy density was then compared between the intact and reconstructed states for all implant positions. Both varus and valgus positioning of the humeral stem altered both the cortical and trabecular bone stresses from the intact states. Valgus positioning had the greatest negative effect in the lateral quadrant for both cortical and trabecular bone, producing greater stress shielding than both the standard and varus positioned implant. Overall, the varus and standard positions produced values that most closely mimicked the intact state. Surprisingly, valgus positioning produced large amounts of stress shielding in the lateral cortex at both 45˚ and 75˚ of abduction but resulted in a slight decrease in stress shielding in the medial quadrant directly beneath the humeral resection plane. This might have been a result of direct contact between the distal end of the implant and the medial cortex under loading which permitted load transfer, and therefore load-reduction of the lateral cortex during abduction. Conversely, when the implant was placed in the varus angulation, noticeable departures in stress shielding and changes in bones stress were not observed when compared to the optimal STD position. Interestingly, for the varus positioned implant, the deflection of the humerus under load eliminated the distal stem-cortex contact, hence preventing distal load transfer thus precluding the transfer of load


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_12 | Pages 28 - 28
23 Jun 2023
Massè A Giachino M Audisio A Donis A Secco D Turchetto L Limone B Via RG Aprato A
Full Access

Ganz's studies made it possible to address joint deformities on both femoral and acetabular side brought by the Legg-Calvè-Perthes disease (LCPD). Femoral head reduction osteotomy (FHRO) was developed to improve joint congruency along with periacetabular osteotomy (PAO). The purpose of this study is to show the clinical and morphologic outcomes of the technique, and an implemented planning approach. From 2015 to 2023, 13 FHROs were performed on 11 patients for LCPD, in two centers. 11 of 13 hips had an associated PAO. A specific CT and MRI-based protocol for virtual simulation of the corrections was developed. Outcomes were assessed with radiographic parameters (sphericity index, extrusion index, integrity of the Shenton's line, LCE angle, Tonnis angle, CCD angle) and clinical parameters (ROM, VAS, Merle d'Aubigné-Postel score, modified-HHS, EQ5D-5L). Early and late complications were reported. The mean follow-up was 40 months. The mean age at surgery was 11,4 years. No major complications were recorded. One patient required a total hip arthroplasty. Femoral Head Sphericity increased from 45% to 70% (p < 0,001); LCE angle from 18° to 42,8° (p < 0,001); extrusion Index from 36,6 to 8 (p < 0,001); Tonnis Angle from 14,4° to 6,2° (p = 0.1); CCD Angle from 131,7 to 136,5° (p < 0,023). The VAS score improved from 3,25 to 0,75,(p = 0.06); Merle d'Aubigné-Postel score from 14.75 to 16 (p = 0,1); Modified-HHS from 65,6 to 89,05 (p = 0,02). The EQ 5D 5L showed significant improvements. ROM increased especially in abduction and extra-rotation. FHRO associated with periacetabular procedures is a safe technique that showed improved functional, clinical and morphologic outcomes in LCPD. The newly introduced simulation and planning algorithm may help to further refine the technique


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_7 | Pages 52 - 52
4 Apr 2023
García-Rey E Saldaña L
Full Access

Pelvic tilt can vary over time due to aging and the possible appearance of sagittal spine disorders. Cup position in total hip arthroplasty (THA) can be influenced due to these changes. We assessed the evolution of pelvic tilt and cup position after THA and the possible appearance of complications for a minimum follow-up of ten years. 343 patients received a THA between 2006 and 2009. All were diagnosed with primary osteoarthritis and their mean age was 63.3 years (range, 56 to 80). 168 were women and 175 men. 250 had no significant lumbar pathology, 76 had significant lumbar pathology and 16 had lumbar fusion. Radiological analysis included sacro-femoral-pubic (SFP), acetabular abduction (AA) and anteversion cup (AV) angles. Measurements were done pre-operatively and at 6 weeks, and at five and ten years post-operatively. Three measurements were recorded and the mean obtained at all intervals. All radiographs were evaluated by the same author, who was not involved in the surgery. There were nine dislocations: six were solved with closed reduction, and three required cup revision. All the mean angles changed over time; the SFP angle from 59.2º to 60º (p=0.249), the AA angle from 44.5º to 46.8º (p=0.218), and the AV angle from 14.7º to 16.2º (p=0.002). The SFP angle was lower in older patients at all intervals (p<0.001). The SFP angle changed from 63.8 to 60.4º in women and from 59.4º to 59.3º in men, from 58.6º to 59.6º (p=0.012). The SFP angle changed from 62.7º to 60.9º in patients without lumbar pathology, from 58.6º to 57.4º in patients with lumbar pathology, and from 57.0º to 56.4º in patients with a lumbar fusion (p=0.919). The SFP cup angle was higher in patients without lumbar pathology than in the other groups (p<0.001), however, it changed more than in patients with lumbar pathology or fusion at ten years after THA (p=0.04). Posterior pelvic tilt changed with aging, influencing the cup position in patients after a THA. Changes due to lumbar pathology could influence the appearance of complications long-term


The Bone & Joint Journal
Vol. 102-B, Issue 2 | Pages 246 - 253
1 Feb 2020
Alluri RK Lightdale-Miric N Meisel E Kim G Kaplan J Bougioukli S Stevanovic M

Aims. To describe and analyze the mid-term functional outcomes of a large series of patients who underwent the Hoffer procedure for brachial plexus birth palsy (BPBP). Methods. All patients who underwent the Hoffer procedure with minimum two-year follow-up were retrospectively reviewed. Active shoulder range of movement (ROM), aggregate modified Mallet classification scores, Hospital for Sick Children Active Movement Scale (AMS) scores, and/or Toronto Test Scores were used to assess functional outcomes. Subgroup analysis based on age and level of injury was performed. Risk factors for subsequent humeral derotational osteotomy and other complications were also assessed. A total of 107 patients, average age 3.9 years (1.6 to 13) and 59% female, were included in the study with mean 68 months (24 to 194) follow-up. Results. All patients demonstrated statistically significant improvement in all functional outcomes and active shoulder abduction and external rotation ROM (p < 0.001). Patients < 2.5 years of age had higher postoperative AMS, abduction ROM and strength scores, and aggregate postoperative Toronto scores (p ≤ 0.035) compared to patients ≥ 2.5 years old. There were 17 patients (16%) who required a subsequent humeral derotational osteotomy; lower preoperative AMS external rotation scores and external rotation ROM were predictive risk factors (p ≤ 0.016). Conclusion. Patients with BPBP who underwent the Hoffer procedure demonstrated significant improvement in postoperative ROM, strength, and functional outcome scores at mid-term follow-up. Patients younger than 2.5 years at the time of surgery generally had better functional outcomes. Limited preoperative external rotation strength and ROM were significantly associated with requirement for subsequent humeral derotational osteotomy. In our chort significant improvements in shoulder function were obtained after the Hoffer procedure for BPBP. Cite this article: Bone Joint J 2020;102-B(2):246–253


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_7 | Pages 67 - 67
1 Jul 2020
Pelet S Pelletier-Roy R
Full Access

Surgeries for reverse total shoulder arthroplasty (RTSA) significantly increased in the last ten years. Initially developed to treat patients with cuff tear arthropathy (CTA) and pseudoparalysis, wider indications for RTSA were described, especially complex proximal humerus fractures. We previously demonstrated in patients with CTA a different sequence of muscular activation than in normal shoulder, with a decrease in deltoid activation, a significant increase of upper trapezius activation and slight utility of the latissimus dorsi. There is no biomechanical study describing the muscular activity in patients with RTSA for fractures. The aim of this work is to describe the in vivo action of RTSA in patients with complex fractures of the proximal humerus. We conducted an observational prospective cohort study comparing 9 patients with RTSA for complex humerus fracture (surgery more than 6 months, healed tuberosities and rehabilitation process achieved) and 10 controls with normal shoulder function. Assessment consisted in a synchronized analysis of range of motion (ROM) and muscular activity on electromyography (EMG) with the use of 7 bipolar cutaneous electrodes, 38 reflective markers and 8 motion-recording cameras. Electromyographic results were standardized and presented in muscular activity (RMS) adjusted with maximal isometric contractions according to the direction tested. Five basic movements were evaluated (flexion, abduction, neutral external rotation, external rotation in 90° of abduction and internal rotation in 90° of abduction). Student t-test were used for comparative descriptive analysis (p < 0,05). The overall range of motion with RTSA is very good, but lower than the control group: flexion 155.6 ± 10 vs 172.2 ± 13.9, p<0.05, external rotation at 90° 55.6 ± 25 vs 85.6 ± 8.8, p<0,05, internal rotation at 90° 37.8 ± 15.6 vs 52.2 ± 12, p<0,05. The three heads of the deltoid are more stressed during flexion and abduction in the RTSA group (p. The increased use of the 3 deltoid chiefs does not support the hypothesis proposed by Grammont when the RTSA is performed for a complex proximal humerus fracture. This can be explained by the reduced dispalcement of the rotation center of the shoulder in these patients compared to those with CTA. These patients also didn't present shoulder stiffness before the fracture. The maximal muscle activity of the trapezius in flexion and of the latissimus dorsi in flexion and abduction had not been described to date. These new findings will help develop better targeted rehabilitation programs. In addition, the significant role of the latissimus dorsi must question the risks of its transfer (L'Episcopo procedure) to compensate for external rotation deficits


Bone & Joint Open
Vol. 4, Issue 11 | Pages 853 - 858
10 Nov 2023
Subbiah Ponniah H Logishetty K Edwards TC Singer GC

Aims. Metal-on-metal hip resurfacing (MoM-HR) has seen decreased usage due to safety and longevity concerns. Joint registries have highlighted the risks in females, smaller hips, and hip dysplasia. This study aimed to identify if reported risk factors are linked to revision in a long-term follow-up of MoM-HR performed by a non-designer surgeon. Methods. A retrospective review of consecutive MoM hip arthroplasties (MoM-HRAs) using Birmingham Hip Resurfacing was conducted. Data on procedure side, indication, implant sizes and orientation, highest blood cobalt and chromium ion concentrations, and all-cause revision were collected from local and UK National Joint Registry records. Results. A total of 243 hips (205 patients (163 male, 80 female; mean age at surgery 55.3 years (range 25.7 to 75.3)) with MoM-HRA performed between April 2003 and October 2020 were included. Mean follow-up was 11.2 years (range 0.3 to 17.8). Osteoarthritis was the most common indication (93.8%), and 13 hips (5.3%; 7M:6F) showed dysplasia (lateral centre-edge angle < 25°). Acetabular cups were implanted at a median of 45.4° abduction (interquartile range 41.9° - 48.3°) and stems neutral or valgus to the native neck-shaft angle. In all, 11 hips (4.5%; one male, ten females) in ten patients underwent revision surgery at a mean of 7.4 years (range 2.8 to 14.2), giving a cumulative survival rate of 94.8% (95% confidence interval (CI) 91.6% to 98.0%) at ten years, and 93.4% (95% CI 89.3% to 97.6%) at 17 years. For aseptic revision, male survivorship was 100% at 17 years, and 89.6% (95% CI 83.1% to 96.7%) at ten and 17 years for females. Increased metal ion levels were implicated in 50% of female revisions, with the remaining being revised for unexplained pain or avascular necrosis. Conclusion. The Birmingham MoM-HR showed 100% survivorship in males, exceeding the National Institute for Health and Care Excellence ‘5% at ten years’ threshold. Female sex and small component sizes are independent risk factors. Dysplasia alone is not a contraindication to resurfacing. Cite this article: Bone Jt Open 2023;4(11):853–858


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_1 | Pages 63 - 63
1 Feb 2020
Garcia-Rey E Cimbrelo EG
Full Access

Introduction. Total hip arthroplasty (THA) dislocation has been associated with different risk factors. The main difficulty in analysing dislocation is its low rate of incidence, necessitating large series for study. We assessed factors related with patients, implant characteristics, and quality of the hip reconstruction to better identify their influence on the THA dislocation rate. Material and Methods. Dislocations in 2,732 THAs performed between 2001 and 2016 were assessed with regard to factors related with the patient (gender, age, preoperative diagnosis, lumbar pathology); the implant (femoral head size, bearing surface, stem offset, femoral head/neck ratio); and the surgical technique (approach, cup and stem position, and abductor mechanism reconstruction). Regression analysis was used for different risk factors and Kaplan-Meier for survival analysis. Results. After ERAS implementation, opioid consumption decreased for hospital day one (49.5MME to 35.4MME; p=0.000) and overall hospitalization (79.5MME to 59.5MME; p=0.000). Average LOS decreased (57.84hrs to 51.87hrs; p=0.011), blood transfusion rate was unchanged (4.25% to 3.81%; p=0.725), and disposition to home over skilled nursing facility increased (80.4% to 82.5%; p= 0.022). Unplanned return-to-hospital encounters were unchanged (8.51% to 8.88%; p=0.8486). Readmission trended up during postoperative days 0–30 and trended down during postoperative days 31–90. (1.42% to 2.96%; p=0.1074) and (1.21% to 0.85%; p=0.5748), respectively. There were 92 dislocations (3.4%), of these, 62 were treated conservatively (2.3%) and 30 surgically (1.1%). Survivorship analysis for dislocation was 96.0% (95% CI:95.0–97.0) at 17 years. Among patient-related factors, greater age (p=0.001), lower activity level (p=0.001) and lumbar fusion (p<0.001) were associated with a higher dislocation rate. Among implant-related factors, a ceramic-on-ceramic THA (p<0.001) and a femoral size of 32 or 36 mm in diameter had lower dislocation rates. With regards to surgical technique, a greater acetabular abduction angle (p=0.001) and a greater distance to the hip anatomic center (p=0.006) had higher dislocation rates. A cup position outside Lewinnek´s safe zone (p<0.001) and the abductor mechanism window (p<0.001) also had a higher dislocation rate. Multivariate analysis revealed that only significant lumbar pathology (p=0.001) and lumbar fusion (p<0.001) were significant dislocation-related factors among patient-related factors. Poor reconstruction of the hip rotation (p=0.035), a cup position outside of Lewinnek's safe zone (p<0.001) and the abductor mechanism window (p<0.001) were significantly associated with a higher dislocation risk among surgical technique-associated factors. Conclusions. Significant lumbar spine pathology increases the rate of dislocation. A proper reconstruction of the hip, including appropriate cup position and rotation centre reconstruction of the hip are essential to decrease the risk of dislocation after primary THA. The weakness of the abductor muscles is also an important cause for dislocation


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_13 | Pages 43 - 43
1 Oct 2018
Whiteside LA
Full Access

Introduction. Complete or nearly complete disruption of the gluteus attachment is seen in 10–20% of cases at the time of total hip arthroplasty (THA). Special attention is needed to identify the lesion at the time of surgery because the avulsion often is visible only after a thickened hypertrophic trochanteric bursa is removed. The purpose of this study was to evaluate a technique designed to restore abductor function by transferring the gluteus maximus to compensate for the deficient medius and minimus muscles. Methods. From Jan 1 2009 to Dec 31 2013, 525 primary THAs were performed by the author. After the components were implanted, the greater trochanteric bursa was removed, and the gluteus medius and minimus attachments to the greater trochanter were visualized and palpated. Ninety-five hips (95 patients) were found to have damaged muscle attachments to bone. Fifty-four hips had mild damage consisting of splits in the tendon, but no frank avulsion of abductor tendon from the bone attachment. None had severe atrophy of the abductor muscles, but all had partial fatty infiltration. All hips with this mild lesion had repair of the tendons with #5 Ticron sutures to repair the tendon bundles together, anchored to the greater trochanter. Forty-one hips had severe damage with complete or nearly complete avulsion of the gluteus medius and minimus muscles from their attachments to the greater trochanter. Thirty-five of these hips had partial fatty infiltration of the abductor muscles, but all responded to electrical stimulation. The surface of the greater trochanter was denuded of soft tissue with a rongeur, the muscles were repaired with five-seven #5 Ticron mattress sutures passed through drill holes in the greater trochanter, and a gluteus maximus flap was transferred to the posterior third of the greater trochanter and sutured under the vastus lateralis. Six hips had complete detachment of the gluteus medius and minimus muscles, severe atrophy of the muscles, and poor response of the muscles to electrical stimulation. The gluteus medius and minimus muscles were sutured to the greater trochanter, and the gluteus maximus flap was transferred. Postoperatively, patients were instructed to protect the hip for 8 weeks, then abductor exercises were started. Results. The normal hips all had negative Trendelenburg tests at 2 and 5 years postoperative with mild lateral hip pain reported by 11 patients at 2 years, and 12 patients at 5 years. In the 54 with mild abductor tendon damage treated with simple repair, positive Trendelenburg test was found in 5 hips at 2 years and in 8 hips at 5 years. Lateral hip pain was reported in 7 hips at 2 years, and in 22 at 5 years. In the 35 hips with severe avulsion but good muscle tissue, who had repair with gluteus maximus flap transfer, all had good abduction against gravity and negative Trendelenburg tests at 2 and 5 years postoperative, and none had lateral hip pain. Of the 6 hips with complete avulsion and poor muscle who underwent abductor muscle repair and gluteus maximus flap transfer, all had weak abduction against gravity, mildly positive Trendelenburg sign, and mild lateral hip pain at 2 and 5 years postoperative. Conclusions. Abductor avulsion is uncommon but not rare, and is detected during THA only by direct examination of the tendon and removal of the trochanteric bursa. Simple repair of mild abductor tendon damage did not prevent progressive abductor weakness in some hips; and the increase in number of patients with lateral hip pain from 2 to 5 years suggests progressive deterioration. Augmentation of the repair with a gluteus maximus flap appears to provide stable reconstruction of the abductor muscles, and seemed to restore function in the hips with functioning muscles


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_12 | Pages 109 - 109
1 Dec 2022
Perez SD Britton J McQuail P Wang A(T Wing K Penner M Younger ASE Veljkovic A
Full Access

Progressive collapsing foot deformity (PCFD) is a complex foot deformity with varying degrees of hindfoot valgus, forefoot abduction, forefoot varus, and collapse or hypermobility of the medial column. In its management, muscle and tendon balancing are important to address the deformity. Peroneus brevis is the primary evertor of the foot, and the strongest antagonist to the tibialis posterior. Moreover, peroneus longus is an important stabilizer of the medial column. To our knowledge, the role of peroneus brevis to peroneus longus tendon transfer in cases of PCFD has not been reported. This study evaluates patient reported outcomes including pain scores and any associated surgical complications for patients with PCFD undergoing isolated peroneus brevis to longus tendon transfer and gastrocnemius recession. Patients with symptomatic PCFD who had failed non-operative treatment, and underwent isolated soft tissue correction with peroneus brevis to longus tendon transfer and gastrocnemius recession were included. Procedures were performed by a single surgeon at a large University affiliated teaching hospital between January 1 2016 to March 31 2021. Patients younger than 18 years old, or undergoing surgical correction for PCFD which included osseous correction were excluded. Patient demographics, medical comorbidities, procedures performed, and pre and post-operative patient related outcomes were collected via medical chart review and using the appropriate questionnaires. Outcomes assessed included Visual Analogue Scale (VAS) for foot and ankle pain as well as sinus tarsi pain (0-10), patient reported outcomes on EQ-5D, and documented complications. Statistical analysis was utilized to report change in VAS and EQ-5D outcomes using a paired t-test. Statistical significance was noted with p<0.05. We analysed 43 feet in 39 adults who fulfilled the inclusion criteria. Mean age was 55.4 ± 14.5 years old. The patient reported outcome mean results and statistical analysis are shown in Table one below. Mean pre and post-operative foot and ankle VAS pain was 6.73, and 3.13 respectively with a mean difference of 3.6 (p<0.001, 95% CI 2.6, 4.6). Mean pre and post-operative sinus tarsi VAS pain was 6.03 and 3.88, respectively with a mean difference of 2.1 (p<0.001, 95% CI 0.9, 3.4). Mean pre and post-operative EQ-5D Pain scores were 2.19 and 1.83 respectively with a mean difference of 0.4 (p=0.008, 95% CI 0.1, 0.6). Mean follow up time was 18.8 ± 18.4 months. Peroneus brevis to longus tendon transfer and gastrocnemius recession in the management of symptomatic progressive collapsing foot deformity significantly improved sinus tarsi and overall foot and ankle pain. Most EQ-5D scores improved, but did not reach statistically significant values with the exception of the pain score. This may have been limited by our cohort size. To our knowledge, this is the first report in the literature describing clinical results in the form of patient reported outcomes following treatment with this combination of isolated soft tissue procedures for the treatment of PCFD. For any figures or tables, please contact the authors directly


The Bone & Joint Journal
Vol. 103-B, Issue 7 Supple B | Pages 129 - 134
1 Jul 2021
Ayekoloye CI Abu Qa'oud M Radi M Leon SA Kuzyk P Safir O Gross AE

Aims. Improvements in functional results and long-term survival are variable following conversion of hip fusion to total hip arthroplasty (THA) and complications are high. The aim of the study was to analyze the clinical and functional results in patients who underwent conversion of hip fusion to THA using a consistent technique and uncemented implants. Methods. A total of 39 hip fusion conversions to THA were undertaken in 38 patients by a single surgeon employing a consistent surgical technique and uncemented implants. Parameters assessed included Harris Hip Score (HHS) for function, range of motion (ROM), leg length discrepancy (LLD), satisfaction, and use of walking aid. Radiographs were reviewed for loosening, subsidence, and heterotopic ossification (HO). Postoperative complications and implant survival were assessed. Results. At mean 12.2 years (2 to 24) follow-up, HHS improved from mean 34.2 (20.8 to 60.5) to 75 (53.6 to 94.0; p < 0.001). Mean postoperative ROM was flexion 77° (50° to 95°), abduction 30° (10° to 40°), adduction 20° (5° to 25°), internal rotation 18° (2° to 30°), and external rotation 17° (5° to 30°). LLD improved from mean -3.36 cm (0 to 8) to postoperative mean -1.14 cm (0 to 4; p < 0.001). Postoperatively, 26 patients (68.4%) required the use of a walking aid. Complications included one (2.5%) dislocation, two (5.1%) partial sciatic nerve injuries, one (2.5%) deep periprosthetic joint infection, two instances of (5.1%) acetabular component aseptic loosening, two (5.1%) periprosthetic fractures, and ten instances of HO (40%), of which three (7.7%) were functionally limiting and required excision. Kaplan-Meier Survival was 97.1% (95% confidence interval (CI) 91.4% to 100%) at ten years and 88.2% (95% CI 70.96 to 100) at 15 years with implant revision for aseptic loosening as endpoint and 81.7% (95% CI 70.9% to 98.0%) at ten years and 74.2% (95% CI 55.6 to 92.8) at 15 years follow-up with implant revision for all cause failure as endpoint. Conclusion. The use of an optimal and consistent surgical technique and cementless implants can result in significant functional improvement, low complication rates, long-term implant survival, and high patient satisfaction following conversion of hip fusion to THA. The possibility of requiring a walking aid should be discussed with the patient before surgery. Cite this article: Bone Joint J 2021;103-B(7 Supple B):129–134


The Bone & Joint Journal
Vol. 103-B, Issue 8 | Pages 1333 - 1338
2 Aug 2021
Kankanalu P Borton ZM Morgan ML Cresswell T Espag MP Tambe AA Clark DI

Aims. Reverse total shoulder arthroplasty (RTSA) using trabecular metal (TM)-backed glenoid implants has been introduced with the aim to increase implant survival. Only short-term reports on the outcomes of TM-RTSA have been published to date. We aim to present the seven-year survival of TM-backed glenoid implants along with minimum five-year clinical and radiological outcomes. Methods. All consecutive elective RTSAs performed at a single centre between November 2008 and October 2014 were reviewed. Patients who had primary TM-RTSA for rotator cuff arthropathy and osteoarthritis with deficient cuff were included. A total of 190 shoulders in 168 patients (41 male, 127 female) were identified for inclusion at a mean of 7.27 years (SD 1.4) from surgery. The primary outcome was survival of the implant with all-cause revision and aseptic glenoid loosening as endpoints. Secondary outcomes were clinical, radiological, and patient-related outcomes with a five-year minimum follow-up. Results. The implant was revised in ten shoulders (5.2%) with a median time to revision of 21.2 months (interquartile range (IQR) 9.9 to 41.8). The Kaplan-Meier survivorship estimate at seven years was 95.9% (95% confidence interval (CI) 91.7 to 98; 35 RTSAs at risk) for aseptic mechanical failure of the glenoid and 94.8% (95% CI 77.5 to 96.3; 35 RTSAs at risk) for all-cause revision. Minimum five-year clinical and radiological outcomes were available for 103 and 98 RTSAs respectively with a median follow-up time of six years (IQR 5.2 to 7.0). Median postoperative Oxford Shoulder Score was 38 (IQR 31 to 45); median Constant and Murley score was 60 (IQR 47.5 to 70); median forward flexion 115° (IQR 100° to 125°); median abduction 95° (IQR 80° to 120°); and external rotation 25° (IQR 15° to 40°) Scapular notching was seen in 62 RTSAs (63.2%). Conclusion. We present the largest and longest-term series of TM-backed glenoid implants demonstrating 94.8% all-cause survivorship at seven years. Specifically pertaining to glenoid loosening, survival of the implant increased to 95.9%. In addition, we report satisfactory minimum five-year clinical and radiological outcomes. Cite this article: Bone Joint J 2021;103-B(8):1333–1338


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_6 | Pages 51 - 51
1 Jul 2020
Vachhani K Whyne C Nam D Wong J Chou J Paul R
Full Access

Rotator cuff tears are the most common cause of shoulder disability, affecting 10% of the population under 60 and 40% of those aged 70 and above. Massive irreparable rotator cuff tears account for 30% of all tears and their management continues to be an orthopaedic challenge. Traditional surgical techniques, that is, tendon transfers are performed to restore shoulder motion, however, they result in varying outcomes of stability and complications. Superior capsular reconstruction (SCR) is a novel technique that has shown promise in restoring shoulder function, albeit in limited studies. To date, there has been no biomechanical comparison between these techniques. This study aims to compare three surgical techniques (SCR, latissimus dorsi tendon transfer and lower trapezius tendon transfer) for irreparable rotator cuff tears with respect to intact cuff control using a clinically relevant biomechanical outcome of rotational motion. Eight fresh-frozen shoulder specimens with intact rotator cuffs were tested. After dissection of subcutaneous tissue and muscles, each specimen was mounted on a custom shoulder testing apparatus and physiologic loads were applied using a pulley setup. Under 2.2 Nm torque loading maximum internal and external rotation was measured at 0 and 60 degrees of glenohumeral abduction. Repeat testing was conducted after the creation of the cuff tear and subsequent to the three repair techniques. Repeated measures analysis with paired t-test comparisons using Sidak correction was performed to compare the rotational range of motion following each repair technique with respect to each specimen's intact control. P-values of 0.05 were considered significant. At 0° abduction, internal rotation increased after the tear (intact: 39.6 ± 13.6° vs. tear: 80.5 ± 47.7°, p=0.019). Internal rotation was higher following SCR (52.7 ± 12.9°, intact - SCR 95% CI: −25.28°,-0.95°, p=0.034), trapezius transfer (74.2 ± 25.3°, intact – trapezius transfer: 95% CI: −71.1°, 1.81°, p=0.064), and latissimus transfer (83.5 ± 52.1°, intact – latissimus transfer: 95% CI: −118.3°, 30.5°, p=0.400) than in intact controls. However, internal rotation post SCR yielded the narrowest estimate range close to intact controls. At 60° abduction, internal rotation increased after the tear (intact: 38.7 ± 14.4° vs. tear: 49.5 ± 13°, p=0.005). Internal rotation post SCR did not differ significantly from intact controls (SCR: 49.3 ± 10.1°, intact – SCR: 95% CI: −28°, 6.91°, p=0.38). Trapezius transfer showed a trend toward significantly higher internal rotation (65.7 ± 21.1°, intact – trapezius transfer: 95% CI: −55.7°, 1.7°, p=0.067), while latissimus transfer yielded widely variable rotation angle (65.7 ± 38°, intact – latissimus transfer: 95% CI: −85.9°, 31.9°, p=0.68). There were no significant differences in external rotation for any technique at 0° or 60° abduction. Preliminary evaluation in this cadaveric biomechanical study provides positive evidence in support of use of SCR as a less morbid surgical option than tendon transfers. The cadaveric nature of this study limits the understanding of the motion to post-operative timepoint and the results herein are relevant for otherwise normal shoulders only. Further clinical evaluation is warranted to understand the long-term outcomes related to shoulder function and stability post SCR


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_12 | Pages 20 - 20
1 Dec 2022
Ng G El Daou H Bankes M Cobb J Beaulé P
Full Access

Femoroacetabular impingement (FAI) – enlarged, aspherical femoral head deformity (cam-type) or retroversion/overcoverage of the acetabulum (pincer-type) – is a leading cause for early hip osteoarthritis. Although anteverting/reverse periacetabular osteotomy (PAO) to address FAI aims to preserve the native hip and restore joint function, it is still unclear how it affects joint mobility and stability. This in vitro cadaveric study examined the effects of surgical anteverting PAO on range of motion and capsular mechanics in hips with acetabular retroversion. Twelve cadaveric hips (n = 12, m:f = 9:3; age = 41 ± 9 years; BMI = 23 ± 4 kg/m2) were included in this study. Each hip was CT imaged and indicated acetabular retroversion (i.e., crossover sign, posterior wall sign, ischial wall sign, retroversion index > 20%, axial plane acetabular version < 15°); and showed no other abnormalities on CT data. Each hip was denuded to the bone-and-capsule and mounted onto a 6-DOF robot tester (TX90, Stäubli), equipped with a universal force-torque sensor (Omega85, ATI). The robot positioned each hip in five sagittal angles: Extension, Neutral 0°, Flexion 30°, Flexion 60°, Flexion 90°; and performed hip internal-external rotations and abduction-adduction motions to 5 Nm in each position. After the intact stage was tested, each hip underwent an anteverting PAO, anteverting the acetabulum and securing the fragment with long bone screws. The capsular ligaments were preserved during the surgery and each hip was retested postoperatively in the robot. Postoperative CT imaging confirmed that the acetabular fragment was properly positioned with adequate version and head coverage. Paired sample t-tests compared the differences in range of motion before and after PAO (CI = 95%; SPSS v.24, IBM). Preoperatively, the intact hips with acetabular retroversion demonstrated constrained internal-external rotations and abduction-adduction motions. The PAO reoriented the acetabular fragment and medialized the hip joint centre, which tightened the iliofemoral ligament and slackenend the pubofemoral ligament. Postoperatively, internal rotation increased in the deep hip flexion positions of Flexion 60° (∆IR = +7°, p = 0.001) and Flexion 90° (∆IR = +8°, p = 0.001); while also demonstrating marginal decreases in external rotation in all positions. In addition, adduction increased in the deep flexion positions of Flexion 60° (∆ADD = +11°, p = 0.002) and Flexion 90° (∆ADD = +12°, p = 0.001); but also showed marginal increases in abduction in all positions. The anteverting PAO restored anterosuperior acetabular clearance and increased internal rotation (28–33%) and adduction motions (29–31%) in deep hip flexion. Restricted movements and positive impingement tests typically experienced in these positions with acetabular retroversion are associated with clinical symptoms of FAI (i.e., FADIR). However, PAO altered capsular tensions by further tightening the anterolateral hip capsule which resulted in a limited external rotation and a stiffer and tighter hip. Capsular tightness may still be secondary to acetabular retroversion, thus capsular management may be warranted for larger corrections or rotational osteotomies. In efforts to optimize surgical management and clinical outcomes, anteverting PAO is a viable option to address FAI due to acetabular retroversion or overcoverage


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_1 | Pages 19 - 19
1 Feb 2020
So K
Full Access

Introduction. To control implant alignments (anteversion and abduction angle of the acetabular cup and antetorsion of the femoral stem) within an appropriate angle range is essentially important in total hip arthroplasty to avoid implant impingement. A navigation system is necessary for accurate intraoperative evaluation of implant alignments but is too expensive and time-consuming to be commonly used. Therefore, a cheaper and easier tool for intraoperative evaluation of the alignments is desired in the clinical field. I presented an idea of marking ruler-like scales on a trial femoral head in the last ISTA Congress. The purpose of this study is to introduce an idea further improved in evaluating the combined implant alignment intraoperatively. Materials and Methods. We can evaluate the combined anteversion (sum of cup anteversion and stem antetorsion) and cup abduction angle by reading the scales at the most proximal point of inner edge of the liner when horizontal and vertical scales are marked on the femoral head appropriately and the hip joint is kept at the neutral position after implant settings and trial reduction. Whether the impingement occurred within the target ROM (Flx 130, IR40@Flx90, Ext 40, ER 40) was judged under specific conditions of the oscillation angle (139), neck-shaft angle of the stem (130), stem adduction angle (7), stem antetorsion (20 or 30), and cup anteversion and abduction angles. Cup anteversion and abduction angles were changed from 0 to 40 and 30 to 50 degrees in 1-degree increments, respectively. Impingement judgment was performed mathematically for each combination of implant alignment based on matrix transformations and trigonometric formulas. Results. Impingement-free combinations of implant alignments were identified using spreadsheet software. Points which indicated impingement-free when they matched with the most proximal point of the inner edge of the liner when the hip joint was kept neutral were plotted on the surface of the head on a 3-dimensional computer graphic software. Thus, the safe zone could be indicated visually on the trial head by a collection of these points. Discussion. We can easily judge whether the implant impingement occurs or not by using this trial head intraoperatively. However, there are several factors which make the judgment inaccurate. First, the safe zone varies according to the stem antetorsion. Second, the position at which the hip is kept intraoperatively is not necessarily neutral. Third, stem adduction angle varies according to the length of the femur. Conclusion. Safe zone mapping on the trial femoral head is low cost and easy method to be introduced in the clinical practice for the purpose of a rough judgment of implant impingement


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_9 | Pages 9 - 9
1 Jun 2021
Greene A Verstraete M Roche C Conditt M Youderian A Parsons M Jones R Flurin P Wright T Zuckerman J
Full Access

INTRODUCTION. Determining proper joint tension in reverse total shoulder arthroplasty (rTSA) can be a challenging task for shoulder surgeons. Often, this is a subjective metric learned by feel during fellowship training with no real quantitative measures of what proper tension encompasses. Tension too high can potentially lead to scapular stress fractures and limitation of range of motion (ROM), whereas tension too low may lead to instability. New technologies that detect joint load intraoperatively create the opportunity to observe rTSA joint reaction forces in a clinical setting for the first time. The purpose of this study was to observe the differences in rTSA loads in cases that utilized two different humeral liner sizes. METHODS. Ten different surgeons performed a total of 37 rTSA cases with the same implant system. During the procedure, each surgeon reconstructed the rTSA implants to his or her own preferred tension. A wireless load sensing humeral liner trial (VERASENSE for Equinoxe, OrthoSensor, Dania Beach, FL) was used in lieu of a traditional plastic humeral liner trial to provide real-time load data to the operating surgeon during the procedure. Two humeral liner trial sizes were offered in 38mm and 42mm curvatures and were selected each case based on surgeon preference. To ensure consistent measurements between surgeons, a standardized ROM assessment consisting of four dynamic maneuvers (maximum internal to external rotation at 0°, 45°, and 90° of abduction, and a maximum flexion/extension maneuver) and three static maneuvers (arm overhead, across the body, and behind the back) was completed in each case. Deidentified load data in lbf was collected and sorted based on which size liner was selected. Differences in means for minimum and maximum load values for the four dynamic maneuvers and differences in means for the three static maneuvers were calculated using 2-tailed unpaired t-tests. RESULTS. No significant differences were observed for the flexion/extension maneuver between the 38mm and 42mm liner sizes, but a significant difference was observed for every internal/external rotation assessment at 0°, 45°, and 90° of abduction. No significant differences were observed for the across the body and overhead maneuvers, but a significant difference was observed for the behind the back maneuver (p = 0.015). Standard deviations were pronounced across all maneuvers. CONCLUSION. This study observed significant differences in intraoperative load values in rTSA when comparing different humeral liner sizes. Limitations of this study include the small sample sizes and large standard deviations observed, as well as comparing across multiple patients and multiple surgeons. Area for future work includes comparing load values with postoperative functional results and complication risks for short, midterm, and long-term outcomes in efforts to find the optimal load range for a given patient


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_8 | Pages 76 - 76
1 Aug 2020
Habis A Bicknell R Mei X
Full Access

Reverse shoulder arthroplasty (RSA) has an increasing effective use in the treatment of patients with a variety of diagnoses, including rotator cuff deficiency, inflammatory arthritis, or failed shoulder prostheses. Glenoid bone loss is not uncommonly encountered in these cases due to the significant wear. Severe bone loss can compromise glenoid baseplate positioning and fixation, consequently increasing the risk for early component loosening, instability, and scapular notching. To manage severe glenoid bone deficiencies, bone grafts are commonly used. Although, many studies report outcome of bone grafting in revision RSA, the literature on humeral head autograft for glenoid bone loss in primary RSA is less robust. The purpose of this study is to evaluate the clinical and radiographic outcomes of primary RSA with humeral head autograft for glenoid bone loss at our institution. Institutional review board approval was obtained to retrospectively review the records of 22 consecutive primary RTSA surgeries in 21 patients with humeral head autograft for glenoid bone loss between January 2008 and December 2016. Five patients died during follow-up, three were unable to be contacted and one refused to participate, leaving a final study cohort of 12 patients with 13 shoulders that underwent RSA. All patients had a clinical evaluation including detailed ROM and clinical evaluation using the American Shoulder and Elbow Surgeons (ASES) Score, Constant Score, Western Ontario Osteoarthritis of the Shoulder Index (WOOS), and Short Form-12 (SF-12) questionnaires. Preoperative and postoperative plain radiographs and CT scans were assessed for component position, loosening, scapular notching, as well as graft incorporation, resorption, or collapse. There were 6 males and 6 females, with an average age of 74 ± 6.8 years. The average BMI was 31.7 ± 5.3, and the median ASA score was 3. Average follow-up was 3.4 ± 1.1 years. The average postoperative range of motion measurements for the operative arm are: flexion = 120 ± 37, abduction = 106 ± 23, external rotation = 14 ± 12, internal rotation at 90 degrees of abduction = 49 ± 7, external rotation at 90 degrees of abduction = 50 ± 28. Average functional scores are: ASES: 76.9 ± 19.2, WOOS: 456 ± 347, SF12 physical: 34.2 ± 8.2, SF12 mental: 54.1 ± 10.2, Constant Score: 64.6 ± 14. No evidence of hardware loosening or evidence of bone graft resorption were encountered. On CT, the average of pre operative B-angle was 79.3 ± 9.3 while the pre operative reverse shoulder angle was 101.4 ± 28. Glenoid retroversion average on CT was 13.3 ± 16.6. Post operative baseplate inclination average was 82 ± 7.4 while the baseplate version 7.8 ±10. The operative technique was able to achieve up to 30 degrees of inclination correction and up to 50 degrees of version correction. In conclusion, primary reverse shoulder arthroplasty with humeral head autograft for glenoid bone loss provides excellent ROM and functional outcomes at mid-term follow-up. This technique has a high rate of bone incorporation and small risk of bone resorption at mid term follow up


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_8 | Pages 115 - 115
1 May 2019
Berry D
Full Access

The main challenges in hip arthrodesis takedown include the decision to perform fusion takedown and the technical difficulties of doing so. In addition to the functional disadvantages of hip fusion, the long-term effects of hip arthrodesis include low back pain and in some cases ipsilateral knee pain. Indications for fusion conversion to THA include arthrodesis malposition, pseudoarthrosis, and ipsilateral knee, low back, contralateral hip problems, and functional disadvantages of ipsilateral hip fusion. When deciding whether or not to take down fusion, consider the severity of the current problem, risks of takedown and likely benefits of takedown. Best results of fusion takedown occur if abductor function is likely to be present. If the abductors are not likely to function well, dearthrodesis may still help, but the patient will have a profound Trendelenburg or Duchenne gait and risk of hip instability will be higher. Abductor assessment can be performed by determining if the abductors contract on physical exam and determining if the previous form of fusion spared the abductors and greater trochanter. EMG and MRI also can be performed to assess the abductors, but value in this setting is unproven. Before dearthrodesis establish realistic expectations: most patients will gain hip motion—but not normal motion, most will see improvement in back/knee pain, but many will become cane-dependent for life. The main technical issues to overcome involve exposure, femoral neck osteotomy, acetabular preparation, and femoral fixation. Exposure can be conventional posterior, anterolateral or direct anterior with an in-situ femoral neck cut. In complex cases, a transtrochanteric approach is often helpful. The in-situ neck cut is facilitated by fluoroscopy or intraoperative radiograph to make sure the cut is at the correct level and at the correct angle. Be careful not to angle into the pelvis with the cut. Acetabular preparation is more complex because anatomic landmarks often are absent or distorted. Try to find landmarks including ischium, ilium, teardrop, and fovea. Confirm location with fluoroscopy as reaming commences and during reaming. Depth of reaming can be improved by using the fovea (if present) and teardrop on fluoroscopy. Cup fixation is usually an uncemented cup, fixed with multiple screws because bone quality typically is compromised. Femoral fixation is at the surgeon's discretion, recognizing the proximal bone may be distorted in some cases. Postoperative management includes protected weight bearing as needed and heterotopic bone prophylaxis in selected patients


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_11 | Pages 79 - 79
1 Dec 2020
Stefanou M Vasilakou A Fryda Z Giannakou S Papadimitriou G Pilichou A Antonis K Anastasopoulos I
Full Access

Purpose. Ultrasound of the neonatal and infantile hip is a useful tool in diagnosis and treatment of the developmental dysplasia of the hip (DDH), especially given the fact that numerous cases of DDH do not present any findings in the clinical examination. Methods. Between January 2014 and May 2020, 10536 (5273 neonates and infants, 53% girls, 47% boys) consecutive neonatal and infantile hip joints were studied using the Graf Hip Ultrasound method. Results. 607 hips were diagnosed as abnormal. 523 (5%) hip joints were type IIA, 18 (0.17%) were type ΙΙΒ, 19 (0.18%) were type ΙΙC, 33 (0.31%) were type ΙΙΙ and 14 (0.13%) were type IV. 72% of patients were girls, 55% of patients were firstborns, 35,7% presented breech, 8,2% had a positive family history of DDH, 6% were part of a multiple pregnancy, while 27,2% had no predisposing factor for the disease. Type ΙΙΑ hips were treated with follow- up only and had all matured (turned to normal- type I hips) within a trimester. Type ΙΙΒ και ΙΙC hips were treated using an abductor harness and were normal (type I) within three months. 35.7% of type ΙΙΙ were treated with an abductor harness and 64.3% with hip spica. All type IV hips were treated with hip spica. The duration of therapy for type III and type IV hips was 3 months. Conclusion. The early use of a hip ultrasound provides us with the ability to diagnose and treat DDH efficiently, resulting in a normal hip joint within the first months of life


The Bone & Joint Journal
Vol. 103-B, Issue 2 | Pages 353 - 359
1 Feb 2021
Cho C Min B Bae K Lee K Kim DH

Aims. Ultrasound (US)-guided injections are widely used in patients with conditions of the shoulder in order to improve their accuracy. However, the clinical efficacy of US-guided injections compared with blind injections remains controversial. The aim of this study was to compare the accuracy and efficacy of US-guided compared with blind corticosteroid injections into the glenohumeral joint in patients with primary frozen shoulder (FS). Methods. Intra-articular corticosteroid injections were administered to 90 patients primary FS, who were randomly assigned to either an US-guided (n = 45) or a blind technique (n = 45), by a shoulder specialist. Immediately after injection, fluoroscopic images were obtained to assess the accuracy of the injection. The outcome was assessed using a visual analogue scale (VAS) for pain, the American Shoulder and Elbow Surgeons (ASES) score, the subjective shoulder value (SSV) and range of movement (ROM) for all patients at the time of presentation and at three, six, and 12 weeks after injection. Results. The accuracy of injection in the US and blind groups was 100% (45/45) and 71.1% (32/45), respectively; this difference was significant (p < 0.001). Both groups had significant improvements in VAS pain score, ASES score, SSV, forward flexion, abduction, external rotation, and internal rotation throughout follow-up until 12 weeks after injection (all p < 0.001). There were no significant differences between the VAS pain scores, the ASES score, the SSV and all ROMs between the two groups at the time points assessed (all p > 0.05). No injection-related adverse effects were noted in either group. Conclusion. We found no significant differences in pain and functional outcomes between the two groups, although an US-guided injection was associated with greater accuracy. Considering that it is both costly and time-consuming, an US-guided intra-articular injection of corticosteroid seems not always to be necessary in the treatment of FS as it gives similar outcomes as a blind injection. Cite this article: Bone Joint J 2021;103-B(2):353–359


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_16 | Pages 50 - 50
1 Dec 2021
Mehta S Mahajan U Sathyamoorthy P
Full Access

Abstract. Background. The influence of diagnosis on outcomes after reverse shoulder arthroplasty (RSA) is not completely understood. The purpose of this study was to compare clinical outcomes of different pathologies. Methods. A total of 78 RSAs were performed for the following diagnoses: (1) rotator cuff tear arthropathy(RCA), (2) massive cuff tear(MCT) with osteoarthritis(OA), (3) MCT without OA, (4) arthritis, (5) acute proximal humerus fracture. Mean follow up 36 months (upto 5 years) Range of motion, Oxford Shoulder Score were obtained preoperatively and postoperatively. Results. Mean OSS was 30. The RCA, MCT-with-OA, MCT-without-OA, and arthritis groups all exhibited significant improvements in all outcome scores and in all planes of motion. After adjustment for age and compared with RCA, those with OA had significantly better abduction (P < .05), and those with fractures had significantly worse patient satisfaction (P < .05). Among male patients, those with MCTs without OA had significantly worse satisfaction (P < .05). Conclusion. RSA reliably provides improvement regardless of preoperative diagnosis. Although subtle differences exist between male and female patients, improvements in clinical outcome scores were apparent after RSA


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_15 | Pages 108 - 108
1 Aug 2017
Ries M
Full Access

Abductor deficiency after THA can result from proximal femoral bone loss, trochanteric avulsion, muscle destruction associated with infection, pseudotumor, ALTR to metal debris, or other causes. Constrained acetabular components are indicated to control instability after THA with deficient abductors. However, the added implant constraint also results in greater stresses at the modular liner-locking mechanism of the constrained component and bone-implant fixation interface, which can contribute to mechanical failure of the constrained implant or mechanical loosening. Use of large heads has been effective in reducing the rate of dislocation after primary THA. However, relatively large (36mm) heads were not found to be effective in controlling dislocation in patients with abductor deficiency. Dual mobility implants which can provide considerably larger head diameters than 36mm may offer an advantage in improving stability in patients with abductor deficiency. However the utility of these devices in controlling instability after THA with deficient abductors has not been established. Whiteside has described a transfer of the tensor muscle and anterior gluteus maximus to the greater trochanter for treatment of absent abductors after THA. Transposition of the tensor muscle requires raising an anterior soft tissue flap to the lever of the interval between the tensor muscle and sartorius, which is the same interval used in an anterior approach to the hip. The muscle is transected distally and transposed posteriorly to attach to the proximal femur. This can result in soft tissue redundancy between the posterior tensor muscle and anterior gluteus maximus. This interval is separated and the anterior gluteus maximus also attached to the proximal femur. The transposed tensor muscle provides muscle coverage over the greater trochanter, which may be beneficial in controlling lateral hip pain. In our practice, 11 patients were treated with Whiteside's tensor muscle transfer. Six patients had absent abductors, one had an avulsed greater trochanter, and four intact but weak abductors. One patient had a muscle transposition alone, one had an ORIF of the greater trochanter and muscle transposition, two had a muscle transposition and head/liner exchange, three had a muscle transposition and cup revision, two had a femoral revision and liner exchange with muscle transposition, and two had a muscle transposition with both component revision. None of the patients had constrained components. The mean pre-operative abductor strength was 2.2 (0/5 in four patients 3/5 in four patients, and 4/5 in three patients). Pre-operative lateral hip pain was none or mild in two patients, moderate in three, and severe in six patients. Mean post-operative abductor strength was 3.2 (2/5 in four patients, 3/5 in three, 4/5 in two, 5/5 in two patients). Post-operative lateral hip pain was none in five and mild in six patients. One patient sustained a dislocation four weeks after surgery which was treated with open reduction. All of the other hips have remained stable. Treatment of patients with hip instability and abductor deficiency has generally required use of a constrained acetabular component. In our experience, transfer of the tensor muscle and anterior gluteus maximus to the greater trochanter can improve abductor strength by one grade and also reduce lateral hip pain. The combination of a large head and tensor muscle transposition may be a viable alternative to use of a fully constrained component in patients with deficient abductors after THA. However, the need for implant constraint should also be individualised and based on factors such as the viability of the transposed muscle, patient compliance with post-operative activity restrictions, femoral head/neck ratio, and cup position


The Bone & Joint Journal
Vol. 100-B, Issue 10 | Pages 1399 - 1404
1 Oct 2018
Biedermann R Riccabona J Giesinger JM Brunner A Liebensteiner M Wansch J Dammerer D Nogler M

Aims. The purpose of this study was to analyze the incidence of the different ultrasound phenotypes of developmental dysplasia of the hip (DDH), and to determine their subsequent course. Patients and Methods. A consecutive series of 28 092 neonates was screened and classified according to the Graf method as part of a nationwide surveillance programme, and then followed prospectively. Abnormal hips were followed until they became normal (Graf type I). Type IIb hips and higher grades were treated by abduction in a Tübinger orthosis until normal. Dislocated hips underwent closed or open reduction. Results. Overall, 90.2% of hips were normal at birth. Type IIa hips (8.9%) became normal at a median of six weeks (interquartile range (IQR) 6 to 9). Type IIc and IId hips (0.67%) became normal after ten weeks (IQR 7 to 13). There were 19 type lll and eight type lV hips at baseline. There were 24 closed reductions and one open reduction. No late presentations of DDH were detected within the first five years of life. Conclusion. The incidence of DDH was eight per 1000 live births. The treatment rate was 1% (n = 273). The rate of first operations on the newborn hip was 0.86, and rate of open surgery was 0.04. The cumulative rate of open surgery was 0.07. The authors take the view that early identification and treatment in abduction of all dysplastic hips in early childhood reduces the rate of open reduction and secondary DDH-related surgery later in life. Cite this article: Bone Joint J 2018;100-B:1399–1404


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_1 | Pages 112 - 112
1 Jan 2017
Valente G Crimi G Cavazzuti L Benedetti M Tassinari E Taddei F
Full Access

In the congenital hip dysplasia, patients treated with total hip replacement (THR) often report persistent disability and pain, with unsatisfactory function and quality of life. A major challenge is to restore the center of rotation of the hip and a satisfactory abduction function [1]. The position of the acetabular cup during THR might be crucial, as it affects abduction moment and motor function. Recently, several software systems have been developed for surgical planning of endoprostheses. Previously developed software called HipOp [2], which is routinely used in clinics, allows surgeons to properly position the prosthetic components into the 3D space of CT data. However, this software did not allow to simulate the articular range of motion and the condition of the abductor muscles. Our aim is to present HipOpCT, an advanced version of the software that includes 3D musculoskeletal planning, through the application to hip dysplasia patients to add knowledge in the diagnosis and treatment of such patients who need THR. 40 hip dysplasia patients received pre-operative CT scanning of pelvis and thighs and had their THR surgery planned using HipOpCT. The base planning includes import of CT data, positioning of prosthetic components interactively through multimodal display, as well as geometrical measurements of the implant and the host bone. The advanced planning additionally includes evaluation of femoro-acetabular impingement and calculation of leg lengths, abductor muscle lengths and lever arms through the automatic creation of a musculoskeletal model. The musculoskeletal parameters in all patients were calculated during the surgical planning, and the data were processed to evaluate pre- and post-operative differences in leg length discrepancy, length and lever arm of the abductor muscles, and how these parameters correlated. The surgical planning led to an increase in the operated leg length of 7.6 ± 5.7 mm. The variation in abductors lever arm was −0.9% ± 4.8% and significantly correlated with the variation in the operated leg length (r = −0.49), pre-operative leg length discrepancy (r = 0.32) and variation in abductors length (r = −0.32). The variation in abductors length was 6.6% ± 5.5%, and significantly correlated with the variation in the operated leg length (r = 0.92), post-operative leg length discrepancy (r = 0.37), pre-operative abductors length (r = −0.37) and variation in abductors lever arm (r = −0.32). The increase in the operated leg length was strongly correlated to the increase in abductor muscle length. Conversely, abductor lever arms slightly decreased on average, and were inversely correlated to leg length variation and abductors lengths. This interactive technology for surgical planning represent a powerful tool for orthopaedic surgeons to consider the best muscle reconstruction, and for rehabilitation specialists to achieve the best functional recovery based on biomechanical outcomes. In a parallel study, we are investigating how these advanced planning is reflected onto the function, pain and biomechanical outcome after a rehabilitation protocol is completed


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_3 | Pages 7 - 7
1 Apr 2018
Hafez M Cameron R Rice R
Full Access

Keywords. Complete Abductor Detachament, Direct Lateral Approach, Abductor Insuffenciency, Hip Arthroplasty. Backgroung. Approach of Total hip replacement (THR) is a very important part of the surgery, the approach dictates the postoperative complications. Lateral approach is one of the most commonly used approaches. The initial lateral approach relied on bony (trochanteric) osteotomy which was later modified to tendon detachment, there are many versions of the lateral approach but the main goal is to detach the hip abductors mechanism to gain access to the underlying joint. One of the modifications is to completely detach the abductors tendon, this offers superior exposure compared to the traditional partial detachment (Hardinge) approach. Objectives. We aimed to perform the first study comparing the complications rate following complete detachment of hip abductors to the documented complications rate of the traditional approach. Study Design & Methods. Retrospective study to evaluate the rate of approach specific complications following complete abductor detachment approach, we included s all patients who had THR using this approach 8–18 months ago. The study group comprised of 44 patients of different age groups and genders. Patients were reviewed to assess gait abnormality, abductor weakness with Trendlenberg test, lateral trochanteric pain (LTP) and heterotopic ossification (H.O). Results. Out of the 44 patients in our study group 20 patients had abductor weakness with positive Trendelnberg test (45.5%) while the reported percentage of abductor weakness following the traditional approach is 4–20%.7 patients (15%) were dissatisfied with the postoperative gait. LTP was reported in 5 patients (11%) compared to 4.9% associated with standard lateral approach. In our series 9 (20.4%) patients had H.O which is within the acceptable range (up to 25%). Conclusions. Complete abductor detachment approach offers better exposure and quicker alternative to the traditional lateral approach of the hip (Hardinge) but on the other hand it has relatively higher complication rate


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_16 | Pages 46 - 46
1 Dec 2021
Yarwood W Kumar KHS Ng KCG Khanduja V
Full Access

Abstract. Purpose. The aim of this study was to assess how biomechanical gait parameters (kinematics, kinetics, and muscle force estimations) differ between patients with camtype FAI and healthy controls, through a systematic search. Methods. A systematic review of the literature from PubMed, Scopus, and Medline and EMBASE via OVID SP was undertaken from inception to April 2020 using PRISMA guidelines. Studies that described kinematics, kinetics, and/or estimated muscle forces in cam-type FAI were identified and reviewed. Results. The search strategy identified 404 articles for evaluation. Removal of duplicates and screening of titles and abstracts resulted in full-text review of 37 articles with 12 meeting inclusion criteria. The 12 studies reported biomechanical data on a total of 173 cam-FAI (151 cam specific, 22 mixed type) patients and 177 healthy age, sex and BMI matched controls. Cam FAI patients had reduced hip sagittal plane ROM (Mean difference −3.00 0 [−4.10, −1.90], p<0.001), reduced hip peak extension angles (Mean Difference −2.05 0[−3.58, −0.53], p=0.008), reduced abduction angles in the terminal phase of stance, and reduced iliacus and psoas muscle force production in the terminal phase of stance compared to the control groups. Cam FAI cohorts walked at a slower speed compared to controls. Conclusions. In conclusion, patients with cam-type FAI exhibit altered sagittal and frontal plane kinematics as well as altered muscle force production during level gait compared to controls. These findings will help guide future research into gait alterations in FAI and how such alterations may contribute to pathological progression and furthermore, how such alterations can be modified for therapeutic benefit