Introduction. After total hip arthroplasty, dislocation is one of the most frequent serious early complications. This occurs in part due to impingement (catching and leverage of the neck-cup on the inlay/cup border). Impingement may also negatively impact long-term outcomes. Materials and Methods. A preliminary model for an optimised hip endoprosthesis system was developed to offer a mechanical solution to avoid impingement and dislocation. A computer-supported range of motion simulation using parameters of cup anteversion and inclination as well as torsion and CCD shaft angle was then performed to localise areas of anterior and posterior impingement of typical acetabular cups. Results. Through isolation of the two main trajectories of motion, and modifications with corresponding gaps to the inlay/cup areas as well as oppositional banking in the abduction/adduction plane, the combination of a snap-fit acetabular cup with reduced cup profile was the result: the “bidirectional
Aims: The authors report oncological and functional results after 15 acetabular reconstructions, followed tumor resection, with an original technique using homo-lateral proximal femoral autograft and
Because we encountered a high failure rate of the acetabular component of the uncemented, hydroxy-apatite coated, Omnifit
The ABG
Purpose: The surgical approach is an essential element for precise reduction and rigid fixation of fractures of the acetabulum. In cases where the anterior column is mainly involved and total hip arthroplasty (THA) is indicated, classical approaches do not allow double assess to the anterior column necessary for reduction and fixation and to the femoral canal for insertion of the prosthesis. Combining Heuter’s anterior approach and Letournel’s ilio-femoral approach provides access to the anterior column and to the often associated posterior hemi-transverse fracture, while allowing insertion of the
Introduction. Total hip arthroplasty in young patients is still associated with high failure rates, especially at the acetabular side. Purpose of this study was to evaluate the long-term results of the Alloclassic cementless Zweymüller
Purpose: Wear of prosthetic implants, especially the metal-polyethylene head-cup couple, and dissemination of wear particles throughout the organisms the dominant long-term complication of total hip arthroplasty. We determined serum concentrations of chromium, cobalt, nickel, and molybdenum in patients bearing a
Introduction: “Spongiosa metal” this unique implant surface was introduced in 1982 by ESKA implants Germany. Pore size was between 800 and 1500 microns with an overall porosity of 60%. The pore depth of the interconnecting surface structure reached up to 3000 microns. The purpose of this retrospective study is to report the long term results of Spongiosa Metal I cement less
Purpose: A spacer can be used for two-phase replacement of an infected
SL-PLUS MIA stem (Smith & Nephew Orthopaedics AG) is a modified implant of Zweymuller type SL-PLUS standard stem (Smith & Nephew Orthopaedics AG). We constructed finite element (FE) models and analysed equivalent stresses in the femur. In addition, we measured bone mineral density (BMD) in the femur by dual-energy X-ray absorptiometry (DEXA) after THA. The purpose of this study was to investigate the equivalent stress and to compare the results of the FE analyses with changes in BMD after THA. Twenty-one patients (18 women and 3 men) who underwent primary cementless THA with SL-PLUS MIA or SL-PLUS formed the basis of this study. Eleven patients received SL-PLUS MIA and ten patients received SL-PLUS. Zones were defined according to Gruen's system (zones 1∼7). Computed-tomography (CT) images of the femur were taken before and at 1 week after THA. FE models of the femur and prosthesis were obtained from CT data by Mechanical Finder (Research Center of Computational Mechanics Inc., Tokyo, Japan), software that creates FE models showing individual bone shape and density distribution. Equivalent stresses were analysed in zones 1 to 7 and compared to the DEXA data. FE studies revealed that there was no significant difference in equivalent stress between SL-PLUS MIA and SL-PLUS. BMD was maintained after THA in zones 3, 4, and 5, whereas BMD decreased in zones 2, 6, and 7. In zone 1, BMD decreased in SL-PLUS MIA stem group by 14%, while BMD was maintained in SL-PLUS standard stem.
Introduction: Unique spongiosa like surface structure was introduced in 1982 by ESKA implants Germany. It is called “Spongiosa-Metal I surface” The purpose of this retrospective study is to report and compare long term results of Spongiosa Metal I
INTRODUCTION. Cementless Total Hip Replacement surgery is a well established procedure for relative young patients with severe hip disease. Excellent long term clinical results have been published on the performance of the femoral component. With growing clinical experience, our concern focused on excessive wear of the Ultra High Molecular Weight Polyethylene (UHMWPE) ringloc liner of the Mallory Head cementless
Total Hip Arthroplasty (THA) is a well-established, cost-effective treatment for improving function and alleviating pain in patients who have disabling hip disease with excellent long-term results. Based on the excellent results, there is an ongoing trend for THA to be performed in younger and more active patients, having higher physical demands on their new total joints. Polyethylene (PE) wear and its biological consequences are one of the main causes of implant failure in THA. Macrophages phagocytise PE wear particles and this will result in osteolysis and loss of periprosthetic bone. The risk of these complications can be estimated in relation to the amount of volumetric wear based on two assumptions: that the number of PE particles dispersed in the peri-prosthetic tissues is controlled by the amount of PE wear; and that the development of osteolysis and the resulting aseptic loosening is triggered by these PE particles. Based on these assumptions, a model was developed to estimate the osteolysis-free life of a THA, depending on the Linear Wear Rate (LWR) and femoral head size of the PE bearing. A review of the literature was conducted to provide an estimate of the radiologic osteolysis threshold based on the volumetric wear of the PE bearing. This review demonstrates that this radiologic osteolysis threshold is approximated 670 mm3 for conventional PE. The osteolysis-free life of the THA was estimated by simply dividing this threshold volume by the annual Volumetric Wear Rate (VWR) of the bearing. The annual VWR is basically controlled by two parameters: (1) annual LWR and (2) head size, and was calculated by using published formulae. For 28 mm heads, following osteolysis-free life was determined in function of the annual LWR. LWR: 10 µm/y => 116.6 years / LWR: 25 µm/y => 46.6 years / LWR: 50 µm/y => 23.3 years / LWR: 100 µm/y => 11.6 years. For 40 mm heads, following osteolysis-free life was determined in function of the annual LWR. LWR: 10 µm/y => 57.1 years / LWR: 25 µm/y => 22.9 years / LWR: 50 µm/y => 11.4 years / LWR: 100 µm/y => 5.7 years. The osteolysis-free life determined by this model is in good agreement with the clinical results of PE bearings having a 28 mm head size and demonstrates that extreme low LWRs are mandatory to assure a descent osteolysis-free life for THA (PE bearings) using large heads, such as 40 mm. For such head sizes, small variations of the LWR may have large impacts on the osteolysis-free life of the THA.
Between January 1984 and January 1986, 131 porous-coated anatomic total hip replacements were performed in 119 consecutive patients. Of these, 100 patients (110 hips) who were alive at a minimum of 18 years after replacement were included in the study. The mean age of the patients at surgery was 48.4 years and that of surviving patients at the latest follow-up was 67.8 years. The mean duration of the clinical and radiological follow-up was 19.4 years (18 to 20). The mean Harris hip score initially improved from 55 points before to 95 points at two years after operation, but subsequently decreased to 91 points after six years, 87 points after 11.2 years, and 85 points after 19.4 years. At the final follow-up, 23 hips (18%) of the entire cohort and 21% of survivors had undergone revision because of loosening or osteolysis of the acetabular component and eight hips (6%) of the entire cohort and 7% of survivors for loosening or osteolysis of the femoral component. Only four femoral components (4%) were revised for isolated aseptic loosening without osteolysis and two (2%) for recurrent dislocation. On the basis of these long-term results, the porous-coated anatomic femoral component survived for a minimum of 18 years after operation while the acetabular component was less durable. The findings identify the principles of uncemented joint replacement which can be applied to current practice.
Customization makes it possible to fulfill design requirements during MIS-THA procedures, and has helped define the parameters of fit and fill. This study describes the results of using customization techniques to develop a femoral implant for utilization. CT-based design criteria for femoral implants has-been developed and used for primary, cement-less, non-minimally invasive THA surgery. Over 1000 procedures performed with these devices have been associated with displaced femoral fractures, and have been revised for septic loosening. This study has 2 parts:
20 implants were designed and implanted with CT-based criteria that utilized the identical fit and fill standards of the custom implants previously established, but had short (<
115 mm), tapered stems; 20 patients underwent primary, cement-less THR wherein an off-the-shelf femoral implant system was determined to fulfill fit and fill requirements of custom implants. The stem of these implants was shortened (95–115 mm) and tapered. Implants in both groups were inserted using a single incision, posterior-lateral MIS approach. Patients were followed clinically and radiographically for six months. Immediate full weightbearing and use of a single cane were encouraged. The use of CT-based customization techniques is helpful for defining design criteria of femoral implants, but the instrumentation for inserting these implants must be adapted to the specific surgery. Customization also facilitates the design and evaluation of CAOS applications for inserting these MIS implants.
Early reports on revision total hip arthroplasty (RTHA) suggested that outcomes of this procedure are as good as those of primary total hip arthroplasty (THA). However, RTHA is associated with longer surgery time, greater blood loss and increased risk of complications (thromboembolism, nerve injury, periprosthetic fractures, recurrent hip dislocations and infections). Aseptic loosening after RTHA was reported in 36% of patients aged over 55 years within 4 years after revision. Infections were reported in 32% and complications during surgery in 23% of patients respectively. Unsatisfactory results of RTHA stimulate the search for alternative procedures. Girdlestone excision arthroplasty (GA) seems to be a good solution for older patients with high risk of complications related to a poor general condition.
Infection ceased in 9 cases, 1 patient died because of complications related to chronic infection.
We report the clinical outcome and survival of 100 total hip arthroplasties with Link RS cementless hip prostheses after a mean of 63 months (51 to 93). The average preoperative Merle d'Aubigne hip score was 9.4 points and the average score at the latest follow-up was 15.3 points. Thirteen prostheses have been revised and seven await revision. Survivorship analysis based on intention to revise showed only 68% survival at seven years (95% CI 53% to 81%). The survivals of femoral and acetabular components verified to be loose at surgery were 78% and 89% respectively at seven years. A number of other patients have pain and it seems likely that there will be substantial reduction in these survival figures in the future.
Sixty-five total hip arthroplastics were reinserted after sepsis around the hip, positive cultures being obtained from fifty-six. Although 65 per cent of patients still have their implant in position, only sixteen of sixty-five (25 per cent) show an excellent or good result on a Harris rating. Twenty-three of sixty-five (35 per cent) subsequently required an excision arthroplasty. The indications and contraindications for this procedure are given.
Post op cup anatomical and functional orientation is a key point in THP patients regarding instability and wear. Recently literature has been focused on the consequences of the transition from standing to sitting regarding anteversion, frontal and sagittal inclination. Pelvic incidence (PI) is now considered as a key parameter for the analysis of sagittal balance and sacral slope (SS) orientation. It's influence on THP biomechanics has been suggested. Interestingly, the potential impact of this morphological angle on cup implantation during surgery and the side effects on post op functional orientation have not been studied. Our study explores this topic from a series of standing and sitting post-op EOS images 310 patients (mean age 63,8, mean BMI 30,2) have been included prospectively in our current post-operative EOS protocol. All patients were operated with the same implants and technique using anterior approach in lateral decubitus. According to previous literature, 3 groups were defined: low PI less than 45° (57 cases), high PI if more than 60° (63 cases), and standard PI in 190 other cases.Introduction
Material and methods
We enrolled 98 patients (107 hips) with a mean age of 47 years (SD 8.6) into a prospective study of the Madreporic Lord THR; 34 hips had primary and 73 secondary osteoarthritis. After ten years, the survival rate using revision as the endpoint for failure was 70% (±9) for the cup and 98% (±0.3) for the stem. The combined clinical and radiological survival rates were 46% (±11) and 81% (±10), respectively. Osteoporosis due to stress-shielding was observed in the proximal femur. Hips with radiologically dense bone postoperatively showed the most pronounced bone loss. We recommend continued radiological follow-up of patients with this type of implant to allow revision to be performed before there is severe bony destruction of the pelvis.
Twenty-nine patients with thirty pseudarthroses after removal of infected total hip prostheses have been reviewed one to six years later. Six hips still had a discharging sinus. Complete removal of all cement was found to be essential for healing, and various points in the technique of its clearance have been made. In this respect radio-opaque cement was a great advantage, and lateral guttering of the femur was most effective. Compared with the situation before replacement considerable relief of pain was obtained in most patients but there was much less improvement in function.
The aim of this study is to review the relation of polyethylene wear in patients underwent Anatomic Medullary Locking total hip replacement with respect to the types of acetabulum used. 85 cementless primary AML joint replacements were performed in the 10 years period from 1988 to 1998. The average age at operation was 46.6 with a range from 22 to 63. Two different types of acetabulum design namely the Acetabulum Cup System (ACS) and Duraloc were used. 39 of them were followed up from 2 to 10 years with an average of 69 months. Xrays were performed at the review visit and the thickness of the insert was calculated. The cup abduction angle was measured and the size of the cup and initial insert thickness was also recorded. The findings were correlated and subjected to statistical analysis. Our findings suggested that the wear of the ACS cup was significantly higher than that of the Duraloc cup. The size of the cup but not the age of the patient at the time of operation also affects the wear rate. It appears that wear rate started to accelerate from year 8 onwards. The risk is higher with cups of less than 50mm diameter We conclude that it is advisable to review closely those patients with the ACS cup implanted. Revision surgery should be considered if eccentric wear started to be seen on Xray to avoid complicated procedure.
The shape of the femoral canal is variable, infact more variable than most contemporary designs of femoral components would suggest or accommodate. Clinical and experimental studies of total hip replacement have demonstrated the need for a close geometric fit between the femoral component and the supporting bone for a durable implant fixation. In order to provide a basis for design and selection of femoral components in future, we undertook an anthropometric study of proximal femoral geometry on Indian specimens. 74 cadaveric femorae were studied to analyze the difference in the endosteal and periosteal geometry between Indian and Western population. Standard extra-cortical and endosteal dimensions were determined by direct measurements of radiographs. To enable comparison standard horizontal and vertical axis were established using the geometric center of lesser trochanter and the bisecting axis of the medullary canal at the level of the isthmus. Statistically significant differences were found for the following measurements: Femoral head offset, Width at lesser trochanter, Width at lesser trochanter-20mm, Proximal border of isthmus, Neck shaft angle.
All the measurements were done by two independent observers and averaged. From the standard radiographs, the sacral slope (SS), the acetabular frontal inclination (AFI), and the acetabular sagittal inclination (ASI) were measured in standing, sitting, and lying positions. From the CT scan sections, the anatomical ante-version (AA) was measured in lying position on axial images according to Murray. The results were compared to a previously described protocol replicating standing and sitting positions: CTscan sections were oriented according to sacral slope.
Revision surgery is generally recommended for recurrent dislocation following Total hip arthroplasty (THA). However, dislocation following revision THA continues to remain a problem with further dislocation rates upto 28% quoted in literature. We present early results of one of the largest series in U.K. using dual mobility cemented acetabular cup for recurrent hip dislocation. We retrospectively evaluated 40 patients where revision of hip replacement was performed using cemented dual mobility acetabular prosthesis for recurrent dislocations from March 2006 till August 2009 at our district general hospital by a single surgeon (senior author). The series comprised of 13 men and 27 females with average age of 73.4 years (49-92). The mean follow-up period was 23 months. (36 months –6 months). All the hips that were revised had 3 or more dislocations, some them more than 10 times. The cause of dislocation was multifactorial in majority of cases including acetabular component malpositioning mainly due to loosening and wear. A cemented dual mobility cup was used in all cases. In six cases the femoral stem was also revised.Introduction
Methods
There were three true dislocations (2%): 1) a posterior dislocation on day 24 in a female patient presenting a fracture with impaction of the femoral stem; 2) a posterior dislocation on day 22 in a female patient in very poor general condition (severe cardiorespiratory failure, death at 48 hr); 3) one recurrent posterior dislocation related to major acetabular retroversion, revised at four months.
Total hip arthroplasty in adult patients with congenital high dislocation of the hip (DDH, Crowe type IV) presents many challenges. Various reconstruction methods including iliofemoral distraction lenghtening and custom made prosthesis have been reported but the standard technique for dealing with this problem is femoral shortening with a subtrochanteric osteotomy. There are many reports of different subtrochanteric osteotomy techniques with satisfactory results. Since 1999, we have been using the same anatomic reconstruction principles with a proximally hydroxyapatite coated cementless stem. Surgical technique on the femoral side comprises a short oblique subtrochanteric osteotomy and excision of a segment as indicated for a safe reduction. This usually requires extensive soft tissue releases of the pelvifemoral muscles. Gluteus maximus, tensor fascia latae and adductors are routinely released. However, we don’t want to do any more release until it is absolutely necessary. Preserving the attachment of the abductors and iliopsoas are important for eventual functional outcome. They help stabilizing the joint, avoid limping and promote hip flexion during the initial swing phase of the gait and stair climbing. We never resect neither osteotomize the trochanters and, if a release is unavoidable, it is performed proximally. Thus, it is possible to preserve a complete segment of the proximal femur with a soft tissue envelope. This segment allows for better bone stock, prompt healing, reliable proximal fixation through the intact medial calcar and, avoids the complications of trochanteric osteotomy. With this technique we have not observed a femoral revision for any reason in 101 high dislocated hips (in 84 patents), since 1999. Compared with other techniques for arthroplasty in patients with developmental hip dysplasia, this surgical technique has a better functional outcome and a low prevalence of revision. To evaluate the effect of this reconstruction on gait parameters we analyzed the gait cycle in 17 hips in 10 patients before and after the the total hip arthroplasty and compared it with the patients with hip arthroplasty due to primary osteoarthritis. Our aim is to determine the restoration of normal anatomy in DDH patients compared to the patients with total hip arthroplasty but a normal hip anatomy. As a result we have demon-strated that our technique restores normal gait parameters by improving walking speed, lengthening step-stride length, correcting hip and knee flexion and ankle equinus, improving hip and knee stiffness during gait and helps to restore normal gait parameters
We report the long-term radiographic results of the total hip arthroplasty with use of the cementless porous coated Harris-Galante (H-G) stem. Seventy-five consecutive patients, eighty-eight hips formed the basis of this study. Fifty patients were male, twenty-five patients were female, and thirteen patients were bilateral. The mean age of patients at operation was 42 years. They were followed up for an average of thirteen years four months (ten years two months to fourteen years four months). The diagnosis was avascular necrosis of the femoral head in 49 cases, degenerative osteoarthritis in 32 cases. Clinical results were estimated by modified Harris hip score and thigh pain, and radiographic results by periodically checked plain X-ray film. The average Harris hip score increased from 60 points preoperatively to 83 points at the most recent follow-up examination. The hip pain score increased from 31 points to 41 points. Clinically severe thigh pain was observed in 3 cases (4%). In radiographic evaluation, subsidence more than 5mm was seen in 2 cases (2%). Periprosthetic osteolytic lesion was observed in 15 cases (17%), but the lesions do not influence stability of the stem. Femoral stem stability by Engh was stable in 72 cases, fibrous stable in 12 cases, unstable in 4 cases. Pedestal formation, cortical hypertrophy of the distal femur, and stress shielding was observed more than 40%. Subcollar resorption was identified in 29% and ectopic ossification in 15%. Revision of the femoral stem was needed in 4 cases for aseptic loosening. At 10 years probability of survival of the stem using Kaplan-Meyer method was 95.5%. Use of the cementless H-G stem yielded the excellent long-term outcome, but osteolysis and stress shielding would be the main problems to solve.
Ceramic bearings are widely used in total hip arthroplasty (THR) along with metal and polyethylene bearings. There were several studies in past few years evaluating the advantage of one over the other. The young population with high activity levels has an increased risk of wear debris production at bearing surface and subsequent implant failure. Recently, interest and use of a ceramics with high wear resistance has been growing. Early reports on ceramic on ceramic THR have demonstrated excellent clinical and radiological results. To evaluate clinical, functional and radiological outcomes of cement-less ceramic on ceramic primary total Hip Replacement (THR) in young patients (<50 years age) with diagnosis of avascular necrosis femoral head.BACKGROUND CONTEXT
PURPOSE
The aim of this study was to investigate the association between fracture displacement and survivorship of the native hip joint without conversion to a total hip arthroplasty (THA), and to determine predictors for conversion to THA in patients treated nonoperatively for acetabular fractures. A multicentre cross-sectional study was performed in 170 patients who were treated nonoperatively for an acetabular fracture in three level 1 trauma centres. Using the post-injury diagnostic CT scan, the maximum gap and step-off values in the weightbearing dome were digitally measured by two trauma surgeons. Native hip survival was reported using Kaplan-Meier curves. Predictors for conversion to THA were determined using Cox regression analysis.Aims
Methods
Orientation of the acetabular component influences
wear, range of movement and the incidence of dislocation after total
hip replacement (THR). During surgery, such orientation is often
referenced to the anterior pelvic plane (APP), but APP inclination
relative to the coronal plane (pelvic tilt) varies substantially
between individuals. In contrast, the change in pelvic tilt from
supine to standing (dPT) is small for nearly all individuals. Therefore,
in THR performed with the patient supine and the patient’s coronal
plane parallel to the operating table, we propose that freehand placement
of the acetabular component placement is reliable and reflects standing
(functional) cup position. We examined this hypothesis in 56 hips
in 56 patients (19 men) with a mean age of 61 years (29 to 80) using
three-dimensional CT pelvic reconstructions and standing lateral
pelvic radiographs. We found a low variability of acetabular component
placement, with 46 implants (82%) placed within a combined range
of 30° to 50° inclination and 5° to 25° anteversion. Changing from
the supine to the standing position (analysed in 47 patients) was associated
with an anteversion change <
10° in 45 patients (96%). dPT was
<
10° in 41 patients (87%). In conclusion, supine THR appears
to provide reliable freehand acetabular component placement. In
most patients a small reclination of the pelvis going from supine
to standing causes a small increase in anteversion of the acetabular component Cite this article:
Progressive retroversion of a cemented stem is
predictive of early loosening and failure. We assessed the relationship
between direct post-operative stem anteversion, measured with CT,
and the resulting rotational stability, measured with repeated radiostereometric
analysis over ten years. The study comprised 60 cemented total hip
replacements using one of two types of matt collared stem with a
rounded cross-section. The patients were divided into three groups
depending on their measured post-operative anteversion (<
10°,
10° to 25°, >
25°). There was a strong correlation between direct
post-operative anteversion and later posterior rotation. At one
year the <
10° group showed significantly more progressive retroversion
together with distal migration, and this persisted to the ten-year
follow-up. In the <
10° group four of ten stems (40%) had been
revised at ten years, and an additional two stems (20%) were radiologically
loose. In the ‘normal’ (10° to 25°) anteversion group there was
one revised (3%) and one loose stem (3%) of a total of 30 stems,
and in the >
25° group one stem (5%) was revised and another loose (5%)
out of 20 stems. This poor outcome is partly dependent on the design
of this prosthesis, but the results strongly suggest that the initial
rotational position of cemented stems during surgery affects the
subsequent progressive retroversion, subsidence and eventual loosening.
The degree of retroversion may be sensitive to prosthetic design
and stem size, but <
10° of anteversion appears deleterious to
the long-term outcome for cemented hip prosthetic stems. Cite this article:
Introduction. The metal-on-metal (MoM)
Orthopaedic implants, such as femoral heads, sockets and stems, are manufactured with a high degree of smoothness and very low form error in order to function as low wear bearings. The surfaces are subject to both wear and damage during in vivo use. Articulating surfaces naturally wear during normal use. Aseptic loosening associated with osteolysis and release of wear particles is the main reason for revision of total hip arthroplasty (THA). Damage of femoral heads is well known to increase the wear rate at the articulating surface and is vulnerable to scratching during the maneuver of positioning the femoral component into the acetabulum component either in primary as in revision total hip arthroplasties. The findings emphasize the importance of achieving and maintaining good surface finish of the femoral head component. The author presents a very simple and “zero cost” method of preventing scratching of the femoral head of any kind of
Backgrounds. The authors present an analysis of 30 cases of
Introduction. A 68 year old female patient underwent a left total hip replacement for primary osteoarthritis in March 2004. She was referred back by her GP 5 years as she was struggling with mobility and felt there were mice in her hip. It was squeking so loudly that it could be hear at a distance of 25 metres. There was no history of any falls or dislocation in the last 5 years. The implant used was an Exeter/ABG ceramic
Postoperative dislocation following total hip arthroplasty (THA) remains a significant concern with a reported incidence of 1% to 10%. The risk of dislocation is multifactorial and includes both surgeon-related (i.e. implant position, component size, surgical approach) and patient-related factors (i.e. gender, age, preoperative diagnosis, neurologic disorders). While the majority of prior investigations have focused on the importance of acetabular component positioning, recent studies have shown that approximately 60% of “dislocators” following primary THA have an acceptably aligned acetabular component. Therefore, the importance of the relationship between the spine and pelvis, and its impact on functional component position has gained increased attention. Kanawade and Dorr et al. have shown patients can be categorised into having a stiff, normal, or hypermobile pelvis based on their change in pelvic tilt when moving from the standing to seated position. The degree of change in functional position of both the acetabular and femoral components is impacted by the degree of pelvic motion each patient possesses. In the “normal” pelvis, as a patient moves from the standing to seated position the pelvis typically tilts posteriorly, thus increasing the functional anteversion of the acetabular component. However, patients with lumbar degeneration or spine pathology often have a decrease in posterior pelvic tilt in the seated position, thus potentially increasing their risk of dislocation. Bedard et al. noted an 8.3% dislocation risk in patients with a spinopelvic fusion after THA vs. 2.9% in those without. There is the potential that preoperative, dynamic imaging can be used to predict the ideal component position for each individual patient undergoing THA. However, this assumes that a patient's preoperative pelvic motion will be the same following implantation of a
Introduction. Computer navigation is a highly sophisticated tool in orthopedic surgery for component placement in total hip arthroplasty (THA). In order to apply it adequately it is of upmost importance that the targets the surgeon is trying to hit are well-defined. This concept considers all four component orientations: cup inclination (cIncl) and anteversion (cAV), stem antetorsion and neck-to-shaft angle. The optimising goal in this concept is maximising the size of the cSafe-Zone. Methods. A computerised 3D- model of a
The aims of this study were to determine if an increasing serum cobalt (Co) and/or chromium (Cr) concentration is correlated with a decreasing Harris Hip Score (HHS) and Hip disability and Osteoarthritis Outcome Score (HOOS) in patients who received the Articular Surface Replacement (ASR) hip resurfacing arthroplasty (HRA), and to evaluate the ten-year revision rate and show if sex, inclination angle, and Co level influenced the revision rate. A total of 62 patients with an ASR-HRA were included and monitored yearly postoperatively. At follow-up, serum Co and Cr levels were measured and the HHS and the HOOS were scored. In addition, preoperative patient and implant variables and the need for revision surgery were recorded. We used a linear mixed model to relate the serum Co and Cr levels to different patient-reported outcome measures (PROMs). For the survival analyses we used the Kaplan-Meier and Cox regression model.Aims
Methods
Literature surrounding artificial intelligence (AI)-related applications for hip and knee arthroplasty has proliferated. However, meaningful advances that fundamentally transform the practice and delivery of joint arthroplasty are yet to be realized, despite the broad range of applications as we continue to search for meaningful and appropriate use of AI. AI literature in hip and knee arthroplasty between 2018 and 2021 regarding image-based analyses, value-based care, remote patient monitoring, and augmented reality was reviewed. Concerns surrounding meaningful use and appropriate methodological approaches of AI in joint arthroplasty research are summarized. Of the 233 AI-related orthopaedics articles published, 178 (76%) constituted original research, while the rest consisted of editorials or reviews. A total of 52% of original AI-related research concerns hip and knee arthroplasty (n = 92), and a narrative review is described. Three studies were externally validated. Pitfalls surrounding present-day research include conflating vernacular (“AI/machine learning”), repackaging limited registry data, prematurely releasing internally validated prediction models, appraising model architecture instead of inputted data, withholding code, and evaluating studies using antiquated regression-based guidelines. While AI has been applied to a variety of hip and knee arthroplasty applications with limited clinical impact, the future remains promising if the question is meaningful, the methodology is rigorous and transparent, the data are rich, and the model is externally validated. Simple checkpoints for meaningful AI adoption include ensuring applications focus on: administrative support over clinical evaluation and management; necessity of the advanced model; and the novelty of the question being answered. Cite this article:
Objectives. The cytotoxicity induced by cobalt ions (Co. 2+. ) and cobalt nanoparticles (Co-NPs) which released following the insertion of a
Factors associated with high mortality rates in geriatric hip fracture patients are frequently unmodifiable. Time to surgery, however, might be a modifiable factor of interest to optimize clinical outcomes after hip fracture surgery. This study aims to determine the influence of postponement of surgery due to non-medical reasons on clinical outcomes in acute hip fracture surgery. This observational cohort study enrolled consecutively admitted patients with a proximal femoral fracture, for which surgery was performed between 1 January 2018 and 11 January 2021 in two level II trauma teaching hospitals. Patients with medical indications to postpone surgery were excluded. A total of 1,803 patients were included, of whom 1,428 had surgery < 24 hours and 375 had surgery ≥ 24 hours after admission.Aims
Methods
Introduction. The purpose of this study was to experimentally evaluate impingement and dislocation of total hip replacements while performing dynamic movements under physiological-like conditions. Therefore, a hardware-in-the-loop setup has been developed, in which a physical hip prosthesis actuated by an industrial robot interacts with an in situ-like environment mimicked by a musculoskeletal multibody simulation-model of the lower extremity. Methods. The multibody model of the musculoskeletal system comprised rigid bone segments of the lower right extremity, which were mutually linked by ideal joints, and a trunk. All bone geometries were reconstructed from a computed tomography set preserving anatomical landmarks. Inertia properties were identified based on anthropometric data and by correlating bone density to Hounsfield units. Relevant muscles were modeled as Hill-type elements, passive forces due to capsular tissue have been neglected. Motion data were captured from a healthy subject performing dislocation-associated movements and were fed to the musculoskeletal multibody model. Subsequently, the robot moved and loaded a commercially available
Introduction. Lewinnek's Safe-Zone gives recommendations only for cup placement in total hip arthroplasty while the orientation of the neck isn't considered. Furthermore the criteria for cup placement are not clearly defined and the ranges for cup orientation are considerably large. This study introduces new recommandations for the combined placement of both total hip components, when both, cup and stem, are considered. This defines the new dynamic combined safe-zone (cSafe-Zone) which gives clear directions for the optimal combined orientation of both components in order to maximize the intended range of movement (iROM) while reducing the risk for prosthetic impingement and dislocation. Material and Methods. The combined safe-zone outlines the area that encloses all component orientations that achieve the predefined iROM without prosthetic impingement. A computerized 3D-model of a
Several risk factors can and should be addressed during first stage or spacer implantation surgery in order to minimize complications. Technical aspects as well as practical tips and pearls to overcome common nuisances such as spacer instability or femoral and acetabular bone loss will be discussed and shown with pictures. Total joint arthroplasty (TJA) is one of the most successful procedures in orthopaedics and excellent results are expected in virtually all cases. Periprosthetic joint infection (PJI) though unusual, is one of the most frequent and challenging complications after TJA. It is the third most common cause of revision in total hip replacement, responsible for up to 15% of all cases. In the past few years several improvements have been made in the management of an infected
Two-stage exchange revision total hip arthroplasty (THA) performed in case of periprosthetic joint infection (PJI) has been considered for many years as being the gold standard for the treatment of chronic infection. However, over the past decade, there have been concerns about its safety and its effectiveness. The purposes of our study were to investigate our practice, collecting the overall spacer complications, and then to analyze their risk factors. We retrospectively included 125 patients with chronic hip PJI who underwent a staged THA revision performed between January 2013 and December 2019. All spacer complications were systematically collected, and risk factors were analyzed. Statistical evaluations were performed using the Student's Aims
Methods
Introduction. In a recent study we evaluated the clinical and radiographic long-term results as well as the serum metal concentrations of 105 cementless primary
Introduction. Total hip replacement is an established surgical procedure done to alleviate hip pain due to joint diseases. However, this procedure is avoided in yonger patients with higher functional demands due to the potential for early failure. An ideal prosthesis will have have a high endurance against impact loading, with minimal micromotion at the bone cement interface, and a reduced risk of fatigue failure, with a favourable stress distribution pattern in the femur. We study the effect of varying the material properties and design element in a standard cemented total hip using Finite Element Analysis. Methods. A patient-specific 3D model of femur will be constructed from CT scan data, while a Summit® Cemented Hip System (DePuy Orthopedic) will be used to as a control for comparative evaluation. We vary the material stiffness of different parts of the prosthesis(see Fig.1) to formulate a design concept for a new
Introduction. Relative motion at the modular head-neck junction of hip prostheses can lead to severe surface damage through mechanically-assisted corrosion. One factor affecting the mechanical performance of modular junctions is the frictional resistance of the mating surfaces to relative motion. Low friction increasing forces normal to the head-neck interface, leading to a lower threshold for slipping during weight-bearing. Conversely, a high friction coefficient is expected to limit interface stresses but may also allow uncoupling of the interface in service. This study was performed to examine this trade-off using finite element models of the modular head-neck junction. Methods. A finite element model (FEM) of the trunnion/ head assembly of a
Introduction. Total hip arthroplasty (THA) is the most common surgery performed for complications of bipolar arthroplasty. The present study evaluated the functional results and complications associated with this surgery. Patients and Methods. Forty eight hips (48 patients) who had conversion of bipolar arthroplasty to THA between 1998 June and 2013 June, and who were followed-up for more than one year were evaluated. Twenty one hips had conversion surgery to THA using a Fitmore cup with metal-on-metal articulation (28 mm head). Six hips had surgery using the SecurFit cup and three hips, using the Lima LTO cup with ceramic-on-ceramic articulation (28 mm or 32 mm head). Eighteen hips had surgery using a large head metal-on-metal bearing: –MMC (seven hips), ACCIS (six hips) and Magnum (five hips). The average time of follow-up duration was 3.9 years (range, 1.0–11.3). There were 22 men and 26 women between the ages of 28 and 80 years (average, 68.9 years) at the time of conversion surgery. Conversion arthroplasty was performed for acetabular erosion without femoral stem loosening in 19 hips, acetabular cartilage erosion with femoral stem loosening in 13 hips, periprosthetic fracture in 12 hips, and recurrent dislocation in four hips. Results were evaluated using Harris hip score (HHS) and Western Ontario McMaster Universities Osteoarthritis Index (WOMAC) score. The radiographs were analyzed for evidence of acetabular and femoral osteolysis or loosening. The complications were evaluated. Results. The time interval between hemiarthroplasty and conversion
Developmental hip displasia (DHD) still presents as an important problem in our country. Latency in diagnosis and inaccurate treatment causes seconder osteoarthritis in young adults and elder patients. Variable reconstructive surgical procedures as proximal femoral and acetabular osteotomies can be performed, but the most satisfactory functional results are achieved by total hip arthroplasty (THA). In this study, we analyzed the results of the cementless total hip arthroplasties performed in coxarthrosis secondary to developmental hip displasia. Between January 2006 and October 2009, 53 patients diagnosed with hip osteoarthritis secondary to DHD, whom performed 59 total hip arthroplasties in GATA Orthopaedics and Traumatology Clinic were included in the study. 10 of the patients were male (%19), and 43 of them were female (%81). Age of the patients varied between 29 and 78 years and the mean age was 48,7. In 23 patients (%44), THA procedure was performed at the right hip and in 24 patients (%45) at the left hip. 6 patients operadted bilaterally. All patients were followed up 8–38 months (mean 20, 6 months) with clinical and radiological evaluation. The hospitalization period varied between 7–14 days, mean 8,3 days. Posterolateral incision was used at all of the patients. Totally 10 (%17) complications were observed. 5 (%8,5) of them was intraoperative and 5(%8,5) was postoperative. Patients evaluated preoperatively and postoperatively with modified Harris Hip Score. While preoperative mean Harris score was 39,1, the postoperative mean score measured as 90,3. The results were excellent in 52 cases (%88,1), and very good in 7 cases (%11,9). Appropriate implementation of cementless
We report a patient with a peri-acetabular chondrosarcoma which was treated by resection of part of the pelvis and the femoral head. This was followed by replacement with a custom-made titanium alloy pelvic portion and a conventional
The goal of this study was to determine which of two techniques for the treatment of peri-prosthetic femoral shaft fractures has the greatest torsional integrity. The study designed was a laboratory study, using 13 matched pairs of embalmed femurs. The femurs were implanted with a cemented
Four en-bloc resections for malignant tumours of the hip, the peri-acetabular region and the iliac wing were reconstructed using an irradiated hemipelvic allograft together with a
Fluid film lubricating ability of a
Total hip arthroplasty (THA) is a commonly performed surgical procedure for various arthritic conditions that affect the hip joint, and it has proven to be highly effective for the relief of pain and improvement in the quality of life. Despite many recent advances in THA, dislocation continues to be a frequent complication, and the incidence of dislocation ranges from 1% to 5% in primary THAs. The literature abounds with options for the treatment of recurrent dislocation after THA. However, to the best of our knowledge, successful treatment with open reduction of a chronic proximal dislocation after THA has not been reported previously in the literature. We report an unusual case of a chronic prosthetic dislocation that was caused by the buttonholing of a prosthetic femoral head by anterior soft tissue, which impeded reduction. A surprisingly good functional result was achieved by an open reduction and revision operation on a 56-year-old man, who had a chronic dislocation of a
Deep infection, the most serious local complication of total hip replacement, prompted a study of the records of 135 patients (137 hips) thus afflicted in a nationwide survey of Canada. Particular attention has been paid to the natural history of the infection, and the problems of diagnosis are described. Twenty-one patients died after the insertion, or removal, of the prosthesis, and of the survivors of the original 135 patients only eighteen have been able to retain the prosthesis without further problems with the wound. The remaining patients had the prosthesis removed, and most dry wounds. Certain suggestions are made on management. The advice that a second
In acetabular dysplasia, fixation of the acetabular component of a cemented
Background: The purpose of this systematic review was to determine the clinical and radiologic benefit of hydroxyapatite-coating in uncemented primary total hip arthroplasty. Methods: A database of Medline articles published up to september 2007 was compiled and relevant references screened. Studies that satisfied the following selection criteria were included:. a proper randomized controlled trial;. based on a
The purpose of this paper is to review the early results of Prostalac system under licence from Therapeutic Goods Administration for Professor Howie in the management of two stage exchange hip arthroplasty for infection (restricted to Royal Adelaide Hospital) and the addition of vancomycin and teicoplanin powder to tobramycin cement without additional tobramycin. Thirteen patients were treated for an infected THR with the Prostalac system. Preoperative and intra-operative cultures were taken to identify the infective organisms. Vancomycin 3 gm was added to the Prostalac cement mantle per 40 gm packet of antibiotic bone cement containing tobramycin 1 gm. Teicoplanin 2.4 gm was used in one case where the patient had a known vancomycin allergy. Postoperatively patients underwent six weeks of IV antibiotics followed by four to six weeks of oral. A short term successful clinical outcome was determined by implantation of a
A rotationplasty is a unique surgical procedure used to reconstruct after resection of a tumor of the leg or a congenital defect. This procedure avoids phantom pain, limb length discrepancy and infections or implant related complications. The outcome is unusual for cosmesis but very functional. Background: Borggreve first described a rotationplasty in Germany in 1930 for a 12 year old patient whose knee was destroyed by tuberculosis. In 1950 Van Nes modified the procedure. Kotz and Saltzer described in 1982 the use of a modified version of a rotationplasty to treat malignant tumors of the distal femur. Case studies of two such patients will be presented. A 27 year old man had a non-metastic osteosarcoma of his distal femur at the age of five. He underwent chemotherapy and a rotationplasty. Six years after his operation a correction osteotomy was done. He is doing very well physically and mentally. He graduated business studies, went yearly on Alpine skiing on two legs, likes jogging and perceives no limitations in his life (MSTS, TESS, SF-36). A 24 year old man, 14 years after a Ewing-sarcoma of his hip. He underwent chemotherapy and radiation therapy. Thirteen years later he had a pathological fracture after playing soccer. He was treated with a
Introduction. As population grows older, and patients receive primary joint replacements at younger age, more and more patients receive a
Purpose of the study: Implants with multidirectional locking screws theoretically have many advantages for the treatment of periprosthetic fractures. In the event of osteoporotic bone, this system of plate fixation ensures stability and better bone fixation. Using screws anchored in the different angles, we proposed rigid fixation around the prosthesis. We conducted a retrospective analysis of outcomes obtained after treatment of perprosthetic femoral fractures, Vancouver B1 and C, comparing two types of implants with angular stability (straight plate and folded plate). Material and methods: From June 1999 to December 2007, we treated 58 patients with periprothetic fractures of the femur using locking plates. Mean age was 72.4 years, 40 patients were female. Thirty-two patients (55.2%) had a
Introduction: The use of hard-on-hard hip prostheses has highlighted specific problems like the “stripe-wear” and the squeaking. Many authors have related these phenomena to a micro-separation between the cup and the head. The goal of the study was to model the hip kinematics under micro-separation regime in order to develop a computational simulator for
Femoral off-set is the perpendicular distance between femur longitudinal axle and the femoral head’s rotation’s centre. Femoral off-set influences following yardsticks: stability of the joint, range of movement (ROM), muscular forcibleness, solicitations on the femoral component and acetabular component’s usury. From numerous radiographies studies, is shown as off-set is not an indefeasible measure, but an average with a range of variability. Offset is one of the most important yardsticks to consider during the pre-operating planning since, as is broadly documented, it has a positive effect on the functionality of the prosthesis; difficulty remains to individualize the optimal offset value in patient with bilateral coxofemural pathology or carriers of opposite side
Introduction: Primary bone lymphoma is a rare neoplastic disease of bone. Treatment consists predominantly of chemotherapy and radiotherapy. Surgery can be considered for large lytic lesions with impending pathological fractures. This study was performed to find the functional and oncological outcome of patients who underwent limb salvage surgery and custom mega prosthesis for lymphoma of bone. Materials and Methods: Eight patients with lymphoma of bone underwent limb salvage surgery and reconstruction with custom made prosthesis. Males predominated in the study with the average age of 30 years. Lower limb was commonly involved: 6 patients had tumour involving the femur. Five patients had pathological fracture. Resection and reconstruction was done using custom mega prosthesis. Proximal humeral prosthesis was used for proximal humeral tumour and proximal femoral or
Aims: Research was preformed including evaluation of early functional and radiographic results, six months after operative treatment of femoral neck fracture, using hemiarthroplasty and osteosynthesis, and late results, two years and more after operation. Methods: Clinical material comprehended two groups of hundred unselected patients each. Control exams included anamnestic data, and radiographic studies of treated hip. Data were stored in previously prepared research protocol according to applied functional and radiographic scoring systems. Results: Data were analized and compared between groups. Results of hip hemiarthroplasty showed direct influence of age, general state of health, size of prosthesis, use of cement and mode of rehabilitation on outcome of patients. Sex, social state, intercurrent diseases and length of operation showed no influence on outcome. Conclusions: According to this analysis hip hemiarthroplasty is a method of choice in cases of elder cathegory of patients, poor general health state, low mental capacity, short mobility and short life expectancy. In a younger patient group method of choice is ostheosynthesis or
The use of hard-on-hard hip prostheses has highlighted specific problems like the “stripe-wear” and the squeaking. Many authors have related these phenomena to a micro-separation between the cup and the head. The goal of the study was to model the hip kinematics under micro-separation regime in order to develop a computational simulator for
Introduction: Maximum effort should be taken during surgical debridement of an infected hip arthroplasty to remove all implants and cement, as also granulation, devitalized and necrotic tissue. Nevertheless, this process is sometimes technically demanding, risky for bone stock and prolongs the procedure. Residual unremoved polymethylmethacrylate (PMMA) after the resection of infected prosthetic components constitutes a controversial issue. Material and Methods: We analyzed 10 patients with infected
We have studied the effect of hydroxyapatite (HA) coating in 15 ovariectomised and 15 normal rats which had had a sham procedure. Twenty-four weeks after operation, HA-coated implants were inserted into the intramedullary canal of the right femur and uncoated implants into the left femur. The prostheses were removed four weeks after implantation. Twelve specimens in each group had mechanical push-out tests. Sagittal sections of the other three were evaluated by SEM. The bone mineral density (BMD) of the dissected left tibia was measured by dual-energy x-ray absorptiometry. The difference in BMD between the control and ovariectomised tibiae was 35.01 mg/cm. 2. (95% CI, 26.60 to 43.42). The push-out strength of the HA-coated implants was higher than that of the uncoated implants in both groups (p <
0.0001), but the HA-coated implants of the ovariectomised group had a reduction in push-out strength of 40.3% compared with the control group (p <
0.0001). Our findings suggest that HA-coated implants may improve the fixation of a cementless
Objectives: Dislocation is one of the common complications of total hip Arthroplasty. Posterolateral approach and small femoral heads have been shown to be high-risk factors for dislocation of the implanted
Purpose: Using the finite element analysis, the authors analyze the effect of the articulating material properties of the total hip arthroplasty to stress and micro-motion of the proximal femur and the femoral stem. Material and methods: The head (28mm) and the acetabular component (outer diameter = 54mm, liner thickness = 11.4mm) were considered as ceramic on ceramic, cramic on polyethylene, metal on metal, metal on polyethylene and metal on metal-polyethylene. The femur was modeled with different friction coefficients according to the different contact portion of the femoral stem, which was modeled after Omni fit HA #9(Osteonics, Allendale, NJ). Non-linear contact analysis was proceeded in human with body weight 70Kg at one leg standing and stair climbing. Result: The maximal yield strength was always higher in hard-hard coupling. In one leg standing, the site of maximal yield strength was represented at the contact point of articulation. In stair climbing, the site of maximal yield strength was represented at the same site in hand on hard coupling but at the lateral aspect of the neck in hard-soft couplings. There were no changes in the patterns of stress distribution but the micro-motions were up to the limit of bone in growth in hard-hard coouplings. Conclusion: The maximal yield strength and the micro-motions revealed different values according to the articulating materials. These findings were considered valuable information to postoperative management and longavity of the
Objectives: Critical analysis of the results of 1124 patients over 70 years of age treated with an endoprothesis between 1987 and 2000. Patients: Patients over 70 years of age presenting a non-pathological unstable fracture of the femoral neck. Intervention: Depending on age and functional status preinjury, 715 times a hemi-arthroplasty; 409 times a
Model-based Roentgen Stereophotogrammetric Analysis (RSA) measures micromotion of an orthopaedic implant with respect to its surrounding bone, without the use of markers on the implant. In previous studies with a total knee prosthesis, Model-based RSA showed to be very accurate. In this study, Model-based RSA is validated in a phantom experiment of a
Introduction: The Gemini stem (DePuy) is a titanium femoral stem with a modular cobalt chrome femoral head. It has a roughened proximal surface finish to enhance cement bonding and a distal centraliser. Purpose of the study: A retrospective assessment of the performance of the titanium cemented Gemini femoral component. Patients and Methods: 196 patients underwent a 204 total hip replacements using a titanium cemented Gemini stem and an uncemented cup. All the operations were performed by a lateral approach using modern cementing technique. Patients were assessed clinically (Harris hip score) and radiologically (standard AP and lateral x-rays). Results: 11 patients with incomplete clinical and radiological follow-up were excluded from the study, leaving 185 patients (193 hips). 36 patients died with their
Our aim was to determine if the serum levels of bone-resorbing cytokines (IL-1β, TNF-α, IL-6, GM-CSF) are altered in patients with aseptic loosening of a
Aims: To investigate the potential of biological þxation of cementless
Introduction and Objectives: This is a prospective analysis of clinical and radiographic outcomes of
To investigate the potential of biological fixation of cementless
This is a retrospective assessment of the performance of the titanium cemented Gemini femoral component. The Gemini stem (DePuy) is a modular titanium femoral stem with a cobalt chrome femoral head. It has a roughened proximal surface finish to enhance cement bonding and a fixed distal centraliser. 205 total hip replacements were performed using a titanium cemented Gemini stem and an uncemented cup. All the operations were performed by a lateral approach using modern cementing technique. Patients were assessed clinically (Harris hip score) and radiologically. Kaplan Meier Survivorship analysis was used to assess survival. 8 patients were lost and 36 patients died with their
The aim of this study was to compare the results of resection arthroplasty with two-stage re-implantation procedure performed for peri-prosthetic infection of the hip. Patients who have had a resection arthroplasty can expect to have less pain, but their functional recovery is inferior to that which can be obtained after a two-stage re-implantation. Resection arthroplasty is usually unacceptable as a definitive solution for relatively young and active patients. Possible options for the operative treatment of a periprosthetic infection include debridement with retention of the prosthesis, immediate one-stage exchange arthroplasty, and excision arthroplasty – either as a definitive procedure or as the first of a two-stage reconstructive procedure. The choice of a particular treatment is influenced by a number of factors. At the Department of Orthopaedic Surgery in Hradec Králové we performed resection arthoplasty of the hip in 67 patients between 1984 and 1998. Mean age was 67 years (range 44–91). We were able to follow-up 33 of these patients in 1999. At follow-up, replacement of the
The aim of this study is to compare the results of resection arthroplasty with two-stage re-implantation procedure performed for peri-prosthetic infection of the hip. Patients who have had a resection arthroplasty can expect to have less pain, but their functional recovery is inferior to that which can be obtained after a two-stage re-implantation. Resection arthroplasty is usually unacceptable as a definitive solution for relatively young and active patients. Possible options for the operative treatment of a periprosthetic infection include debridement with retention of the prosthesis, immediate one-stage exchange arthroplasty, and excision arthroplasty – either as a definitive procedure or as the first of a two-stage reconstructive procedure. The choice of a particular treatment is influenced by a number of factors. At the Department of Orthopaedic Surgery in Hradec Králové we performed resection arthoplasty of the hip in 67 patients between 1984 and 1998. Mean age was 67 years (range 44–91). We were able to follow-up 33 of these patients in 1999. At follow-up, replacement of the
Ceramic-on-ceramic was shown to have advantageous tribologic properties (low wear and friction). For medical applications two ceramics, alumina and zircona, are available. This case study shows that the combination of different ceramics for hard-hard pairings can be critical. A 57 year old patient received a
We have been using a Charnley type hip prosthesis with an alumina ceramic head. Three sizes of alumina head, 28, 26 and 22mm, were employed and the Ortron 90 Charnley
Introduction and Objectives: The coating of implants with biomaterials seems to be a step further toward the ideal biological integration of an inert implant in live recipient bone where it will be subjected to load and movement. The goal of this study is to present results from 70 hip prostheses with implantation of a bioglass-coated stem. Materials and Methods: The “Grupo para el Estudio del Biovidrio” [Group for the Study of Bioglass] and the Stazione del Vetro de Murano experimented with a biocompatible, osteoconductive bioglass in 1992, creating the Biovetro patent as the first bioglass used for the coating of the CRM
Introduction: A potential cause of premature loosening of the
We hypothesise that the stiffness of the acetabular component influences the stresses transmitted to bone. Thus stress shielding or stress overload of the underlying host bone may be influenced by the choice of fixation method. In addition, we believe that the so called “brake drum effect” plays a significant role in the development of rim stresses and subsequent failure of fixation. We have constructed a jig which allows the direct comparison, under controlled conditions, of contact stresses measured behind the acetabular component of polyethylene controls, uncemented metal backe cups and cemented all polyethylene cups, under physiological load. The design of the jig also allows measurement of stresses transmitted to the acetabular rim of the same three prostheses in order to confirm the presence and magnitude of the brake drum effect. The contact stresses are measured by miniature pressure transducers which are inserted through specially drilled holes in the shell of the jig so that the transducer is flush with the prosthesis under test. A total of 6 transducers are arranged in concentric circles radiating away from the prosthetic dome, so that contact stresses may be directly measured in various parts of the acetabular bed under conditions that reproduce as closely as possible the situation in a
Purpose: Periprosthetic ossification is a frequent complication of total hip arthroplasty and can have a major functional impact. Non-steroidal anti-inflammatory drugs (NSAID) can provide effective prevention but with a risk of morbidity. The purpose of this work was to evaluate the efficacy of an anti-Cox2 agent, cele-coxib, for this indication. Material and methods: Total hip arthroplasty was performed in 42 patients with a relative (gastrointestinal) contraindication for the use of NSAID. These patients were given celecoxib (Celebrxy(r)) 200 mg bid starting the day before the operation and continuing for at least five days. A control group of 42 age- (±3 yr) and sex-matched patients who underwent surgery for the same indication performed by a surgeon with equivalent experience was also established. The control patients were given ketoprofen (Profénidy(r)) 50 mg qid for two days then 150 mg bid for five days. The approach, implant, and other adjuvant treatments were equivalent between the two groups. Ossifications were analysed on the follow-up films taken at least three months after surgery. The Brooker classification was used. The exact Fisher test was used for the statistical analysis. Results: The two groups each included 31 women and eleven men, mean age being the same in the two groups (67.12 yrs). Mean follow-up was very similar (8.44 vs 8.6 months). Aetiologies were: primary degenerative hip (n=30), degenerative hip disease after dysplasia (n=9), sequela of infantile arthritis (n=1), revision
Introduction and Objectives: The purpose of this study is to analyse the clinical and radiographic results of revision
Purpose: Exposure to polyethylene debris and bearing wear is a common feature of
We present our experience with HA-coated
Background: Total Hip Replacements in younger active patients continues to pose a major challenge. Surface replacement techniques, designed to preserve bone stock do not yet have proven long term results. Early cemented designs in this population had high failure rates. Concept of fixation of