We evaluated the clinical results and complications
after
The surgical care of
Aims. Intra-articular (IA) tumours around the knee are treated with
This annotation considers the place of extra-articular
reconstruction in the treatment of anterior cruciate ligament (ACL)
deficiency.
Abstract. Introduction. The aim of this study was to determine if elite athletes could return to professional sport after MCL or PLC reconstruction using LARS ligaments and to demonstrate the safety and efficacy of LARS by reporting sport longevity, subsequent surgeries and complications. Methods. A retrospective review of all
Introduction. To determine if elite athletes can return to professional sport after MCL or posterolateral (PLC) reconstruction using LARS ligaments. The secondary aims are to demonstrate the safety and efficacy of LARS by reporting sport longevity, subsequent surgeries, and complications. Methods. A retrospective review of all
Abstract. Introduction. Anterolateral procedures can reduce the risk of re-rupture after ACL reconstruction in high risk patients however, this effectiveness has never been evaluated in elite athletes. The purpose of this study was to evaluate the effectiveness of lateral
Abstract. Background. Performing lateral
Deformity can be associated with significant bone loss, ligament laxity, soft-tissue contractures, distortion of long bone morphology, and
We performed a prospective, randomised study on 57 patients older than 60 years of age with unstable,
Introduction. Restoration of mechanical axis is one of the main aims during Total Knee Arthroplasty (TKA) surgery. Treatment of osteoarthritis (OA) of the knee with
Introduction. Bone tumours rarely involve the joint surface as cartilage is thought to be a good barrier to tumour spread. When the tumour does cross the surface the surgeon is faced with the dilemma of whether to amputate the limb, resect it without reconstruction or reconstruct with an implant. This paper aims to investigate the oncological and functional outcomes of patients undergoing an
Aims. The aims of this retrospective study were to determine the incidence of
The aim of this review is to evaluate the current
available literature evidencing on peri-articular hip endoscopy
(the third compartment). A comprehensive approach has been set on
reports dealing with endoscopic surgery for recalcitrant trochanteric
bursitis, snapping hip (or coxa-saltans; external and internal),
gluteus medius and minimus tears and endoscopy (or arthroscopy)
after total hip arthroplasty. This information can be used to trigger
further research, innovation and education in
Total knee arthroplasty becomes more challenging when knee arthritis is associated with an
The treatment of patients with osteoarthritis of the knee and associated
Introduction. Arthritic knees requiring total knee replacement may present with additional deformities located along the femur or tibia away from the articular region. These deformities may be congenital, developmental, associated with metabolic bone disease, or acquired as a result of malunited fractures or previous advocated for arthritic knee with ipsilateral
1. One hundred and forty-two cases of
We treated 31 feet in 17 children with myelomeningocele by
Osteochondral fractures of the talus are uncommon. They are classified according to Berndt and Harty, as progressing in severity through four stages. This classification, however, does not address
Aim: To analyse retrospectively patients after subtalar
Aims. The aim of this study was to assess hypertrophy of the extra-articular
tendon of the long head of biceps (LHB) in patients with a rotator
cuff tear. Patients and Methods. The study involved 638 shoulders in 334 patients (175 men, 159
women, mean age 62.6 years; 25 to 81) with unilateral symptomatic
rotator cuff tears. The cross-sectional area (CSA) of the LHB tendon
in the bicipital groove was measured pre-operatively in both shoulders
using ultrasound. There were 154 asymptomatic rotator cuff tears
in the contralateral shoulder. Comparisons were made between those
with a symptomatic tear, an asymptomatic tear and those with no
rotator cuff tear. In the affected shoulders, the CSAs were compared
in relation to the location and size of the rotator cuff tear. . Results. The mean CSA was 21.0 mm. 2 . (4 to 71) in those with
a symptomatic rotator cuff tear, 19.9 mm. 2. (4 to 75) in
those with an asymptomatic rotator cuff tear and 14.1 mm. 2 . (5
to 43) in those with no rotator cuff tear. The mean CSA in patients
with both symptomatic and asymptomatic rotator cuff tears was significantly
larger than in those with no rotator cuff tear (p <
0.001). In
the affected shoulders, there were significant differences between
patients with more than a medium sized posterosuperior cuff tear
and those with an antero-superior cuff tear. . Conclusion . Regardless of the symptoms, there was significant hypertrophy
of the
The aim of this study was to determine the immediate post-fixation stability of a distal tibial fracture fixed with an intramedullary nail using a biomechanical model. This was used as a surrogate for immediate weight-bearing postoperatively. The goal was to help inform postoperative protocols. A biomechanical model of distal metaphyseal tibial fractures was created using a fourth-generation composite bone model. Three fracture patterns were tested: spiral, oblique, and multifragmented. Each fracture extended to within 4 cm to 5 cm of the plafond. The models were nearly-anatomically reduced and stabilized with an intramedullary nail and three distal locking screws. Cyclic loading was performed to simulate normal gait. Loading was completed in compression at 3,000 N at 1 Hz for a total of 70,000 cycles. Displacement (shortening, coronal and sagittal angulation) was measured at regular intervals.Aims
Methods
Aims. This study reviews the use of a titanium mesh cage (TMC) as an
adjunct to intramedullary nail or plate reconstruction of an extra-articular
segmental long bone defect. Patients and Methods. A total of 17 patients (aged 17 to 61 years) treated for a segmental
long bone defect by nail or plate fixation and an adjunctive TMC
were included. The bone defects treated were in the tibia (nine),
femur (six), radius (one), and humerus (one). The mean length of
the segmental bone defect was 8.4 cm (2.2 to 13); the mean length
of the titanium mesh cage was 8.3 cm (2.6 to 13). The clinical and
radiological records of the patients were analyzed retrospectively. Results. The mean time to follow-up was 55 months (12 to 126). Overall,
16 (94%) of the patients achieved radiological filling of their
bony defect and united to the native bone ends proximally and distally,
resulting in a functioning limb. Complications included device failure
in two patients (12%), infection in two (12%), and wound dehiscence
in one (6%). Four patients (24%) required secondary surgery, four
(24%) had a residual limb-length discrepancy, and one (6%) had a
residual angular limb deformity. Conclusion. A titanium mesh cage is a useful adjunct in the treatment of
an
We describe a consecutive series of five patients with bone or soft-tissue sarcomas of the elbow and intra-articular extension treated by complex soft tissue, allograft bone and prosthetic joint replacement after wide
Primary synovial chondromatosis, defined by Jaffe (1951), is a rare, benign arthropathy, of unknown aetiology, distinguished by the chondroid metaplasia of the synovial membrane of the joint, bursa or tendon sheath, which leads to the formation of loose bodies, usually intra-articular. It is characteristically monoarticular and the knee, hip and elbow are the joints most commonly affected. The shoulder is a rare localisation and the
Aims. The aim of this study was to report a single surgeon series of
consecutive patients with moderate hallux valgus managed with a
percutaneous
Aims: The aim of this study is to compare open Bankart procedure and arthroscopic
Aim. The aim of this study was to compare the cost-effectiveness of
intramedullary nail fixation and ‘locking’ plate fixation in the
treatment of
1. A study is presented of 286
Background:
Of 23 children (35 feet) with cerebral palsy who had undergone a Grice
Objective: To evaluate the clinical and radiological outcome of an intra-articular bone-patellar tendon-bone (B-PT-B) anterior cruciate ligament reconstruction in combination with an
Limb-sparing surgery has become the preferred surgical treatment of malignant bone tumours of the knee. In patients with intra-articular extension of their tumour,
A new technique is described for
We describe 129 patients with disabling instability of the knee due to deficiency of the anterior cruciate ligament. They were treated by replacement of the ligament with a Leeds-Keio prosthesis supplemented by an
Many methods of reconstruction for ACL deficiency have been described, but little is known about their biomechanical properties. We examined
Summary Statement. We present a simple and useful geometrical equation system to carry out the pre-operative planning and intra-operative assessments for total knee arthroplasty. These methods are extremely helpful in severely deformed lower limbs. Introduction. Total knee arthroplasty is a highly successful surgery for most of the patients with knee osteoarthritis. With commercial instruments and jigs, most surgeons can correct the deformity and provided satisfactory results. However, in cases with severe
Using finely reconstructed helical pelvis CT scans of ninety-three cases and image analysis software, we define the “Safe Zone” for the
Aim: To evaluate time of union and functional recovery of the shoulder joint in humeral shaft fractures treated with antegrade intramedullary nailing. Methods: During 1998–2002, 29 patients (16 male and 13 female, mean age 43.7 years) with humeral shaft fractures underwent antegrade, proximal locked, intramedullary nailing. A modified
Arthrolysis and dynamic splinting have been used in the treatment of elbow contractures, but there is no standardised protocol for treatment of severe contractures with an arc of flexion <
30°. We present our results of radical arthrolysis with twin incisions with the use of a monolateral hinged fixator to treat very severe
Purpose of the study: Reconstruction of the anterior cruciate ligament (ACL) has become a common procedure. We compared two randomized series: intra-articular (Kenneth-Jones) versus intra- and
From 1982 to 1987 we treated 85
Background. To establish relative fixation strengths of a single lateral locking plate, a double locking plate, and a tibial nail in treatment of proximal tibial
We describe 74 patients with disabling instability of the knee due to isolated anterior cruciate deficiency. None responded to conservative measures or correction of internal derangements. All patients were treated by replacement of the anterior cruciate ligament with the medial third of the patellar tendon as a free graft, supplemented by an
The comparability of studies of
Purpose: To compare the functional outcome and quality-of-life following a displaced
Purpose of the study: For medial osteoarthritis with chronic anterior laxity, we propose an original technique combining subtraction osteotomy and
INTRODUCTION. This study aimed to intra-operatively quantify the improvements in knee stability given both by anatomic double-bundle (ADB) and single-bundle with additional lateral plasty (SBLP) ACL reconstruction using a navigation system. MATERIALS AND METHODS. We prospectively included 35 consecutive patients, with an isolated anterior cruciate ligament injury, that underwent both ADB and SBLP ACL reconstruction (15 ADB, 20 SBLP). The testing protocol included anterior/posterior displacement at 30° and 90° of flexion (AP30–AP90), internal/external rotation at 30° and 90° of flexion (IE 30–IE90) and varus/valgus test at 0° and 30° of flexion (VV0–VV30); pivot-shift (PS) test was used to determine dynamic laxity. The tests were manually performed before and after the ACL reconstruction and the data were acquired by means a surgical navigation system (BLU-IGS, Orthokey, USA). Comparisons of pre- and post-reconstruction laxities were made using paired Student t-test (P=0.05) within the same group; comparison between ADB and SBLP groups was indeed performed using independent Student t-test (P=0.05), analysing both starting pre-operative condition and post-operative one. RESULTS. Statistically significant reduction of the global amount of laxity and global displacement was observed for both reconstructions (p<0.05) in all the performed clinical tests. Statistical differences was found between the two reconstruction considering the recovery (pre-post laxities) due to the each reconstruction, in VV0 (SBLP: 3.7±0.2° and ADB: 2.3±0.5°, p<0.0001) and in IE90 (SBLP: 9.2±3.1° and ADB: 5.0±2.8°, p=0.0022). Statistical differences were also found between the two reconstruction considering the recovery of global displacement, in particular for the lateral compartment during AP90 SBLP: 8.8±1.0 mm, ADB: 6.4±0.4 mm, p<0.0001), for the maximal lateral joint opening during VV0 (SBLP: 4.5±1.2 mm, ADB: 1.2±1.1 mm, p<0.0001) and VV30 (SBLP 3.5±1.3 mm, ADB 1.8±0.1 mm, p=0.0013) and both for the medial and lateral AP displacement during IE90 (in in medial compartment SBLP:5.6±0.6 mm, ADB: 2.7±0.7 mm, p<0.0001, in lateral compartment SBLP:8.2±1.0 mm, ADB: 3.9±0.8 mm, p<0.0001). During PS test ADB patients revealed less “hysteresis” after reconstruction (p=0.0005). Moreover SBLP patients presented more acceleration after the reconstruction compared to ADB and more evident displacement (p=0.0009). DISCUSSION. Both the reconstructions worked similarly for what concerns knee static laxity. The considered
Purpose: The MacIntosch method for reconstruction of the anterior cruciate ligament using a free intra-articular plasty with an
Purpose: The purpose of this study was to: 1) assess outcome of ACL reconstruction with intra- and
The purpose of our study was to determine the effect of 4 weeks and 12 weeks of implantation on the strength of a tendon graft in a bone tunnel using a low-profile fixation device, Evolgate, in an
Posterior extraarticular ischiofemoral hip impingement can be caused by high femoral torsion and is typically located between the ischium and the lesser trochanter. We asked if patients undergoing derotational femoral osteotomies for posterior FAI have (1) decreased hip pain and improved function and evaluated (2) subsequent surgeries and complications? Thirty-three hips undergoing derotational femoral osteotomies between 2005 and 2016 were evaluated retrospectively. Of them 15 hips underwent derotational femoral osteotomies and 18 hips underwent derotational femoral osteotomies combined with varisation (neck-shaft angle >139°). Indication for derotational osteotomies was a positive posterior impingement test in extension and external rotation, high femoral torsion (48° ± 9) on CT scans and limited external rotation. Offset improvement was performed to avoid intraarticular impingement in hips with a cam-type FAI. All patients were female and mean followup was 3 ± 2 (1 – 11) years. At latest followup the positive posterior and anterior impingement test decreased from preoperatively 100% to 5% (p< 0.001) and from preoperatively 85% to 30% (p< 0.001). The mean Merle d'Aubigné Postel score increased from 14 ± 1 (11 – 16) to 16 ± 1 (13 – 17) at latest followup (p< 0.001). At followup 32/33 hips had been preserved and one hip had been converted to a total hip arthroplasty (THA). In two hips (6%) revision osteosynthesis was performed for delayed healing of the femoral osteotomy. Derotational femoral osteotomies for the treatment of posterior extraarticular ischiofemoral impingement caused by high femoral torsion result in decreased hip pain and improved function at midterm followup but had 6% delayed healing rate requiring revision surgery.
The ideal form of fixation for displaced, extra-articular
fractures of the distal tibia remains controversial. In the UK, open
reduction and internal fixation with locking-plates and intramedullary
nailing are the two most common forms of treatment. Both techniques
provide reliable fixation but both are associated with specific
complications. There is little information regarding the functional
recovery following either procedure. We performed a randomised pilot trial to determine the functional
outcome of 24 adult patients treated with either a locking-plate
(n = 12) or an intramedullary nailing (n = 12). At six months, there
was an adjusted difference of 13 points in the Disability Rating
Index in favour of the intramedullary nail. However, this was not
statistically significant in this pilot trial (p = 0.498). A total
of seven patients required further surgery in the locking-plate
group and one in the intramedullary nail group. This study suggests that there may be clinically relevant, functional
differences in patients treated with nail
In a prospective study, we reviewed 72 distal tibial fractures treated by percutaneous plating between July 1996 and June 2001. The patient’s mean age was 36 years (19 to 76). The majority of them were men. Seven fractures were open, with three of them Gustilo grade IIIA. Of 65 closed fractures, 15 were Tscherne grade III. All fractures were type 43A according to AO classification and were less than 5 cm from the ankle joint. Most of the fractures were group A3, with 22 group A3.3. Percutaneous plating was delayed for a mean of five days (2 to 15). Pre-contoured small fragment dynamic compression plate was placed on the medial aspect of the tibia under image intensifier control, through a short distal skin incision. On average, three distal and two proximal screws were inserted. Fibular fractures were stabilised in a similar fashion. Satisfactory fracture reduction was achieved in all cases. Postoperatively a below-knee cast was applied for six weeks and weight-bearing was permitted at eight weeks. Fracture healing occurred within 12 weeks (10 to 16). One patient needed bone grafting for treatment of delayed union. All patients had a functional range of ankle movement. In one patient, breakage of all screws was observed in a united fracture with shortening of the fracture. Local late infection where the skin was tented by skin screw heads occurred in eight patients and was resolved by debridement and hardware removal. Percutaneous plating of type A43 tibial fractures is safe, reproducible and successful and has few complications. The few adverse affects may well be eliminated by the use of newly-introduced low profile plates and screws.
Polyethylene wear debris in TKA arises from several sources, including the tibiofemoral articulation and the interface between the backside surface of the tibial insert and the metal tibial tray. In this study we identify a new source of abrasive damage to the polyethylene bearing surface: impingement of resected bony surfaces, osteophytes and overhanging acrylic cement on the tibial bearing surface during joint motion. One hundred forty-eight tibial components of 24 different designs in a retrieval collection were examined. A digital image of the articular surface of each insert was recorded. The presence, location and projected area of abrasive wear to the non-articulating edges of the insert were assessed using image analysis software. Significant abrasive wear was observed in 24% of the retrievals with cemented femoral components and 9% from non-cemented components. Of the retrievals exhibiting this abrasive wear mode, 46% experienced multiple site damage. The average damage area for each individual abrasive scar was 78±11mm^2. Within the group of worn inserts, the abrasive scars were seen with a frequency of 69% on the extreme medial edge, 19% on the extreme lateral edge, 38% on the posterior-medial edge and 23% on the posterior-lateral edge. In posterior stabilized components with an open femoral box design, scarring of the superior surface of the tibial post was also observed. This proposed mode of damage was confirmed with several retrieved femoral components containing either fixed cement protruding from the posterior condyles, from the medial and lateral edges or osteophytes embedded in the posterior capsule. The corresponding inserts exhibited significant abrasive scarring at those locations. We have observed a previously unrecognized source of polyethylene damage resulting in gouging, abrasion and severe localized damage in cemented and uncemented total knee replacement. Clearly, acrylic cement, in bulk or particulate form, often contributes to severe damage of the tibial surface and improvements to instruments and techniques for cementing are needed to prevent this wear mechanism.
Animal studies examining tendon-bone healing have demonstrated that the overall structure, composition, and organization of direct type entheses are not regenerated following repair. We examined the effect of Low-Intensity Pulsed Ultrasound (LIPUS) on tendon-bone healing. LIPUS may accelerate and augment the tendon-bone healing process through alteration of critical molecular expressions. Eight skeletally mature wethers, randomly allocated to either control group (n=4) or LIPUS group (n=4), underwent rotator cuff surgery following injury to the infraspinatus tendon. All animals were sacrificed 28 days post surgery to allow examination of early effects of LIPUS. Humeral head – infraspinatus tendon constructs were harvested and processed for histology and immunohistochemical staining for BMP2, Smad4, VEGF and RUNX2. All the growth factors were semiquantitative evaluated. T-tests were used to examine differences which were considered significant at p < 0.05. Levene's Test (p < 0.05) was used to confirm variance homogeneity of the populations. The surgery and LIPUS treatment were well tolerated by all animals. Placement of LIPUS sensor did not unsettle the animals. Histologic appearance at the tendon-bone interface in LIPUS treated group demonstrated general improvement in appearance compared to controls. Generally a thicker region of newly formed woven bone, morphologically resembling trabecular bone, was noted at the tendon-bone interface in the LIPUS-treated group compared to the controls. Structurally, treatment group also showed evidence of a mature interface between tendon and bone as indicated by alignment of collagen fibres as visualized under polarized light. Immunohistochemistry revealed an increase in the protein expression patterns of VEGF (p = 0.038), RUNX2 (p = 0.02) and Smad4 (p = 0.05) in the treatment group. There was no statistical difference found in the expression patterns of BMP2. VEGF was positively stained within osteoblasts in newly formed bone, endothelial cells and some fibroblasts at the interface and focally within fibroblasts around the newly formed vessels. Expression patterns of RUNX2 were similar to that of BMP-2; the staining was noted in active fibroblasts found at the interface as well as in osteoblast-like cells and osteoprogenitor cells. Immunostaining of Smad4 was present in all cell types at the healing interface. The results of this study indicate that LIPUS may aid in tendon to bone healing process in patients who have undergone rotator cuff repair. This treatment may also be beneficial following other types of reconstructive surgeries involving the tendon-bone interface.
The classical Colles fracture (extraarticular, dorsally angulated distal radius fracture) in patients with osteoporotic bone is becoming increasingly more frequent. There still appears to be no clear consensus on the most appropriate surgical management of these injuries. The purpose of this study is to appraise the use of percutaneous extra-focal pinning, in the management of the classical colles fracture. We retrospectively analysed 72 consecutive cases of Colles fractures treated with interfragmentary K-wire fixation, in female patients over sixty years of age, in two orthopaedic centres, under the care of twelve different orthopaedic surgeons. We correlated the radiographic distal radius measurements (ulnar variance, volar tilt, and radial inclination) at the pre-operative and intra-operative stages with the final radiographic outcome.Introduction
Methods
Displaced fractures of the distal humerus are very difficult to treat. Numerous techniques have been developed for internal fixation, e.g. plating, Rush nail fixation, IM nailing etc. Results are not very good in majority of the cases. Conventional ‘antigrade’ nailing sometimes may not be suitable for these types of fractures. This new nail is inserted by a close retrograde technique using a special interlocking system to avoid axillary nerve and rotator cuff damage. This nail also allows stable fixation of these distal fractures via a plate welded its distal end, which maintain the rotational stability. Since 1997 we have treated 15 displaced extra particular fractures using this device. 12 of them were widely displaced fractures, some comminuted, and 3 were pathological fractures. The nail is introduced through the roof of the olecranon fossa, thus leaving the rotator cuff of the shoulder free from any iatrogenic injury. Proximal rotational stability is maintained by a unique ‘Trio Wire’, which passes through the nail and fans out in the head of the humerus. Distal rotational stability is maintained by the transverse plate. In all cases early pain relief was obtained with return of shoulder and elbow functions. By 6 weeks 98% of patients could perform the majority of daily tasks. No significant complication was noted except a loss of extension of the elbow by 10–15 degrees This new nail provides stable fixation of difficult distal humeral fractures, even in cases with poor bone quality. Early pain relief with a rapid return of shoulder and elbow functions denote a successful outcome of these operations.
The Chiari osteotomy and various shelf procedures are used to augment the weight-bearing area in dysplastic acetabula. The new articular surface derives by metaplasia from the acetabular rim and joint capsule, and is therefore of poorer quality than congruous hyaline cartilage. We reviewed 32 patients after augmentation procedures, using conventional radiographs and three-dimensional reconstruction from CT scans. We showed that Chiari osteotomy and shelf procedures generally achieve less than complete cover, especially over the posterolateral quadrant of the femoral head. Our results suggest that alternative methods which reorientate the whole of the acetabulum are the treatment of choice. Augmentation procedures remain as a salvage option when reorientation is inappropriate or the original hyaline cartilage surface is absent, as in subluxed joints with a secondary acetabulum. Computerised assessment is recommended before operation to assess existing cover and the possible extent of provision of new cover.
Distal radius fractures (DRFs) are one of the most common types of fracture and one which is often treated surgically. Standard X-rays are obtained for DRFs, and in most cases that have an intra-articular component, a routine CT is also performed. However, it is estimated that CT is only required in 20% of cases and therefore routine CT's results in the overutilisation of resources burdening radiology and emergency departments. In this study, we explore the feasibility of using deep learning to differentiate intra- and
Anterior cruciate ligament (ACL) graft failure from rupture, attenuation, or malposition may cause recurrent subjective instability and objective laxity, and occurs in 3% to 22% of ACL reconstruction (ACLr) procedures. Revision ACLr is often indicated to restore knee stability, improve knee function, and facilitate return to cutting and pivoting activities. Prior to reconstruction, a thorough clinical and diagnostic evaluation is required to identify factors that may have predisposed an individual to recurrent ACL injury, appreciate concurrent intra-articular pathology, and select the optimal graft for revision reconstruction. Single-stage revision can be successful, although a staged approach may be used when optimal tunnel placement is not possible due to the position and/or widening of previous tunnels. Revision ACLr often involves concomitant procedures such as meniscal/chondral treatment, lateral
Aims. Femoroacetabular impingement (FAI) patients report exacerbation of hip pain in deep flexion. However, the exact impingement location in deep flexion is unknown. The aim was to investigate impingement-free maximal flexion, impingement location, and if cam deformity causes hip impingement in flexion in FAI patients. Methods. A retrospective study involving 24 patients (37 hips) with FAI and femoral retroversion (femoral version (FV) < 5° per Murphy method) was performed. All patients were symptomatic (mean age 28 years (SD 9)) and had anterior hip/groin pain and a positive anterior impingement test. Cam- and pincer-type subgroups were analyzed. Patients were compared to an asymptomatic control group (26 hips). All patients underwent pelvic CT scans to generate personalized CT-based 3D models and validated software for patient-specific impingement simulation (equidistant method). Results. Mean impingement-free flexion of patients with mixed-type FAI (110° (SD 8°)) and patients with pincer-type FAI (112° (SD 8°)) was significantly (p < 0.001) lower compared to the control group (125° (SD 13°)). The frequency of
The anterior cruciate ligament (ACL) is frequently injured in elite athletes, with females up to eight times more likely to suffer an ACL tear than males. Biomechanical and hormonal factors have been thoroughly investigated; however, there remain unknown factors that need investigation. The mechanism of injury differs between males and females, and anatomical differences contribute significantly to the increased risk in females. Hormonal factors, both endogenous and exogenous, play a role in ACL laxity and may modify the risk of injury. However, data are still limited, and research involving oral contraceptives is potentially associated with methodological and ethical problems. Such characteristics can also influence the outcome after ACL reconstruction, with higher failure rates in females linked to a smaller diameter of the graft, especially in athletes aged < 21 years. The addition of a lateral
Anterior cruciate ligament (ACL) injuries are among the most common and debilitating knee injuries in professional athletes with an incidence in females up to eight-times higher than their male counterparts. ACL injuries can be career-threatening and are associated with increased risk of developing knee osteoarthritis in future life. The increased risk of ACL injury in females has been attributed to various anatomical, developmental, neuromuscular, and hormonal factors. Anatomical and hormonal factors have been identified and investigated as significant contributors including osseous anatomy, ligament laxity, and hamstring muscular recruitment. Postural stability and impact absorption are associated with the stabilizing effort and stress on the ACL during sport activity, increasing the risk of noncontact pivot injury. Female patients have smaller diameter hamstring autografts than males, which may predispose to increased risk of re-rupture following ACL reconstruction and to an increased risk of chondral and meniscal injuries. The addition of an
Rotational laxity increases the risk of anterior cruciate ligament (ACL) injuries and residual rotational laxity can result in inferior surgical outcomes and risk of retears. The dynamic rotatory knee stability can be assessed through manual examination, but it is limited to the surgeon's experience and it provides inaccurate measurements, highlighting the need for objective measurement of knee rotational laxity. The objective measurement of knee laxity can help to better identify patients that may benefit from conservative treatment or those that require surgical treatment with or without concomitant
Aims. This study uses prospective registry data to compare early patient outcomes following arthroscopic repair or debridement of the acetabular labrum. Methods. Data on adult patients who underwent arthroscopic labral debridement or repair between 1 January 2012 and 31 July 2019 were extracted from the UK Non-Arthroplasty Hip Registry. Patients who underwent microfracture, osteophyte excision, or a concurrent
Abstract. Introduction. MRI scanning is the establish method of defining intra- and
Sequelae of Legg-Calve -Perthes disease (LCPD) and treatment of developmental dysplasia of the hip (DDH) can present a coxa breva or coxa magna deformity, sometimes associated with coxa vara. This unique deformity decreases the efficiency of the abductor mechanism, causing a Trendelenburg gait and hip pain, leg length discrepancy and leads to intra- and
Abstract. Introduction. The aim of this study was to determine which factors affect a professional footballer's return to play performance level after ACL reconstruction (ACL-R). Additionally, to report their playing performance at 2 and 5 years post ACL-R compared to their preinjury performance. Methods. A retrospective review of a consecutive series of primary ACL-R undertaken in professional footballers between 2005 and 2019 was undertaken. Performance was determined by the number of minutes played and the league level compared to their pre-injury baseline. Playing time (minutes) was classified as same (within 20%), more, or less playing time for each season compared to the one year prior to surgery. Results. Two hundred footballers (mean age 24.1 ± 4.2 years) were included. 194 (97%) returned to professional football. At 2-years after ACL-R 61% of footballers were playing in the same/ higher league, 29% were playing in a lower league and 10% were not playing. At 5-years this was 35%, 37% and 28% respectively. Forty-six percent of footballers were playing the same or more minutes as pre-injury at 2 years post-surgery, 51% were at 3 and 4 years but this reduced to 45% at 5 years. The presence of >50% thickness chondral pathology, ACL-R lacking lateral
Distal femur fractures (DFF) are common, especially in the elderly and high energy trauma patients. Lateral locked osteosynthesis constructs have been widely used, however non-union and implant failures are not uncommon. Recent literature advocates for the liberal use of supplemental medial plating to augment lateral locked constructs. However, there is a lack of proprietary medial plate options, with some authors supporting the use of repurposing expensive anatomic pre-contoured plates. The aim of this study was to investigate the feasibility of a readily available cost-effective medial implant option. A retrospective analysis from January 2014 to June 2022 was performed on DFF (primary or revision) managed with supplemental medial plating with a Large Fragment Locking Compression Plate (LCP) T-Plate (~$240 AUD) via a medial sub-vastus approach. The T-plate was contoured and placed superior to the medial condyle. A combination of 4.5mm cortical, 5mm locking and/or 6.5mm cancellous screws were used, with oblique screw trajectories towards the distal lateral cortex of the lateral condyle. All
This study was performed at Assiut University, Assiut, Egypt. Anterior distal femoral hemiepiphysiodesis (ADFH) using intra-articular plates for the correction of paediatric fixed knee flexion deformities (FKFD) has two main documented complications: postoperative knee pain and implant loosening. This study describes a biomechanical analysis and a preliminary report of a novel
Introduction. Anterior cruciate ligament reconstruction (ACLr) is the most widely published operation in the orthopaedic literature. Over recent years there has been increased interest in the surgical technique and role of concomitant procedures performed during ACLr. The National Ligament Registry (NLR) collects robust data on ACLr performed in the UK. In this registry analysis we explore trends in ACLr surgery and how they relate to published literature and the growing industry portfolio available to surgeons. Methods. Using data from the NLR, 14,352 ACLr performed between 2013–2021 were analysed. High impact papers on ACLr were then cross referenced against this data to see if surgical practice was influenced by literature or whether surgical practice dictated publication. Common trends were also compared to key surgical industry portfolios (Arthrex, Smith and Nephew) to see how new technology influenced surgical practice. Results. The number of ACLr performed in isolation is decreasing. The number of ACL reconstructions involving meniscal surgery shows an increasing trend since 2013, with 57% of ACLr in 2021 now involving meniscus surgery. The number of ACLr with lateral
Aims. The effect of pelvic tilt (PT) and sagittal balance in hips with pincer-type femoroacetabular impingement (FAI) with acetabular retroversion (AR) is controversial. It is unclear if patients with AR have a rotational abnormality of the iliac wing. Therefore, we asked: are parameters for sagittal balance, and is rotation of the iliac wing, different in patients with AR compared to a control group?; and is there a correlation between iliac rotation and acetabular version?. Methods. A retrospective, review board-approved, controlled study was performed including 120 hips in 86 consecutive patients with symptomatic FAI or hip dysplasia. Pelvic CT scans were reviewed to calculate parameters for sagittal balance (pelvic incidence (PI), PT, and sacral slope), anterior pelvic plane angle, pelvic inclination, and external rotation of the iliac wing and were compared to a control group (48 hips). The 120 hips were allocated to the following groups: AR (41 hips), hip dysplasia (47 hips) and cam FAI with normal acetabular morphology (32 hips). Subgroups of total AR (15 hips) and high acetabular anteversion (20 hips) were analyzed. Statistical analysis was performed using analysis of variance with Bonferroni correction. Results. PI and PT were significantly decreased comparing AR (PI 42° (SD 10°), PT 4° (SD 5°)) with dysplastic hips (PI 55° (SD 12°), PT 10° (SD 6°)) and with the control group (PI 51° (SD 9°) and PT 13° (SD 7°)) (p < 0.001). External rotation of the iliac wing was significantly increased comparing AR (29° (SD 4°)) with dysplastic hips (20°(SD 5°)) and with the control group (25° (SD 5°)) (p < 0.001). Correlation between external rotation of the iliac wing and acetabular version was significant and strong (r = 0.81; p < 0.001). Correlation between PT and acetabular version was significant and moderate (r = 0.58; p < 0.001). Conclusion. These findings could contribute to a better understanding of hip pain in a sitting position and
Objectives. Congenital cruciate ligament deficiency is a rare condition that may occur in isolation or in association with longitudinal limb deficiencies such as fibular hemimelia or proximal femoral focal deficiency. Often anomalies of the menisci and their attachments can be very abnormal and impact on surgical management by standard techniques. Arthroscopic surgical knee reconstruction is undertaken to improve symptomatic instability and/or to stabilise and protect the knee for future planned limb lengthening surgery. The aim of this study is to evaluate the arthroscopic findings of patients undergoing surgery for congenital cruciate ligament deficiency, and specifically to determine the frequency and types of meniscal anatomical variations seen in these cases. Methods. Patients undergoing surgery for congenital cruciate ligament deficiency were identified from a prospectively collated database. Diagnosis was confirmed through review of the clinical notes and imaging. Operative notes and 4K saved arthroscopic images and video recordings for these cases were reviewed. Results. Over a six-year period (July 2017 – September 2023), 42 patients underwent surgery for congenital ligament deficiency and tibiofemoral instability (45 surgical episodes). Median age of patients at time of surgery was 10 years (range 4 – 17 years). The most frequent diagnosis was congenital longitudinal limb deficiency syndromes in 27 cases, with the most frequent being fibular hemimelia. Isolated congenital ligament deficiency without any other associated
Distal radius fractures (DRF) are very common injuries. National recommendations (British Orthopaedic Association, National Institute for Health and Care Excellence (NICE)) exist in the UK to guide the management of these injuries. These guidelines provide recommendations about several aspects of care including which type of injuries to treat non-operatively and surgically, timing of surgery and routine follow-up. In particular, current recommendations include considering immobilizing patients for 4 weeks in plaster for those managed conservatively, and operating on fractures within 72 hours for intra-articular injuries and 7 days for
Aims. Tenosynovial giant cell tumour (TGCT) is one of the most common soft-tissue tumours of the foot and ankle and can behave in a locally aggressive manner. Tumour control can be difficult, despite the various methods of treatment available. Since treatment guidelines are lacking, the aim of this study was to review the multidisciplinary management by presenting the largest series of TGCT of the foot and ankle to date from two specialized sarcoma centres. Methods. The Oxford Tumour Registry and the Leiden University Medical Centre Sarcoma Registry were retrospectively reviewed for patients with histologically proven foot and ankle TGCT diagnosed between January 2002 and August 2019. Results. A total of 84 patients were included. There were 39 men and 45 women with a mean age at primary treatment of 38.3 years (9 to 72). The median follow-up was 46.5 months (interquartile range (IQR) 21.3 to 82.3). Localized-type TGCT (n = 15) predominantly affected forefoot, whereas diffuse-type TGCT (Dt-TGCT) (n = 9) tended to panarticular involvement. TGCT was not included in the radiological differential diagnosis in 20% (n = 15/75). Most patients had open rather than arthroscopic surgery (76 vs 17). The highest recurrence rates were seen with Dt-TGCT (61%; n = 23/38), panarticular involvement (83%; n = 5/8), and after arthroscopy (47%; n = 8/17). Three (4%) fusions were carried out for osteochondral destruction by Dt-TGCT. There were 14 (16%) patients with Dt-TGCT who underwent systemic treatment, mostly in refractory cases (79%; n = 11). TGCT initially decreased or stabilized in 12 patients (86%), but progressed in five (36%) during follow-up; all five underwent subsequent surgery. Side effects were reported in 12 patients (86%). Conclusion. We recommend open surgical excision as the primary treatment for TGCT of the foot and ankle, particularly in patients with Dt-TGCT with
Aims. Instability remains a challenging problem in both primary and
revision total hip arthroplasty (THA). Dual mobility components
confer increased stability, but there are concerns about the unique
complications associated with these designs, as well as the long-term
survivorship. Materials and Methods. We performed a systematic review of all English language articles
dealing with dual mobility THAs published between 2007 and 2016
in the MEDLINE and Embase electronic databases. A total of 54 articles
met inclusion criteria for the final analysis of primary and revision
dual mobility THAs and dual mobility THAs used in the treatment
of fractures of the femoral neck. We analysed the survivorship and
rates of aseptic loosening and of intraprosthetic and extra-articular
dislocation. Results. For the 10 783 primary dual mobility THAs, the incidence of aseptic
loosening was 1.3% (142 hips); the rate of intraprosthetic dislocation
was 1.1% (122 hips) and the incidence of
Introduction. We assessed the role of four different High Tibial osteotomies (HTOs) for medial compartment osteoarthritis of knee (MCOA): Medial Opening Wedge High Tibial Osteotomy (MOWHTO), Focal Dome Osteotomy with Ilizarov Fixator (FDO-I), intra-articular, Tibial Condylar Valgus Osteotomy with plating (TCVO-P) and intra-articular plus
Distal radius fractures are among the most common fractures seen in the emergency department. Closed reduction can provide definitive management when acceptable radiographic parameters are met. Repeated attempts of closed reduction are often performed to improve the alignment and avoid operative management. However, multiple reduction attempts may worsen dorsal comminution and lead to eventual loss of reduction, resulting in no demonstrable benefit. We hypothesize that compared to one closed reduction attempt, repeated closed reduction of
Distal radius fractures are among the most common fractures seen in the emergency department. Closed reduction can provide definitive management when acceptable radiographic parameters are met. Repeated attempts of closed reduction are often performed to improve the alignment and avoid operative management. However, multiple reduction attempts may worsen dorsal comminution and lead to eventual loss of reduction, resulting in no demonstrable benefit. We hypothesize that compared to one closed reduction attempt, repeated closed reduction of
There is enough evidence to show that navigation improves precision of component placement and consistent and accurate restoration of limb alignment, allowing the surgeon to achieve the desired neutral or kinematic alignment. Computer-assisted TKA provides excellent information regarding gap equality and symmetry throughout the knee range of motion. Accurate soft-tissue balancing is facilitated by CAS. It allows precise, quantitative soft tissue release for deformities, especially in knees with severe flexion contractures and severe rigid varus and valgus deformities. It allows accurate restoration of joint line, and posterior femoral offset. Knee arthritis with complex
The extent of soft-tissue release and the exact structures that need to be released to correct deformity and balance the knee has been a controversial subject in primary total knee arthroplasty. Asian patients often present late and consequently may have profound deformities due to significant bone loss and contractures on the concave side, and stretching of the collateral ligament on the convex side.
Soft-tissue release plays an integral part in primary total knee arthroplasty by ‘balancing’ the knee. Asian patients often present late and consequently may have large deformities due to significant bone loss and contractures medially, and stretching of the lateral collateral ligament.
Introduction and Objective. Malunion after trauma can lead to coronal plane malalignment in the lower limb. The mechanical hypothesis suggests that this alters the load distribution in the knee joint and that that this increased load may predispose to compartmental arthritis. This is generally accepted in the orthopaedic community and serves as the basis guiding deformity correction after malunion as well as congenital or insidious onset malalignment. Much of the literature surrounding the contribution of lower limb alignment to arthritis comes from cohort studies of incident osteoarthritis. There has been a causation dilemma perpetuated in a number of studies - suggesting malalignment does not contribute to, but is instead a consequence of, compartmental arthritis. In this investigation the relationship between compartmental (medial or lateral) arthritis and coronal plane malalignment (varus or valgus) in patients with post traumatic unilateral limb deformity was examined. This represents a specific niche cohort of patients in which worsened compartmental knee arthritis after
Introduction. High tibial osteotomy (HTO) is a commonly used surgical technique for treating moderate osteoarthritis (OA) of the medial compartment of the knee by shifting the center of force towards the lateral compartment. The amount of alignment correction to be performed is usually calculated prior to surgery and it's based on the patient's lower limb alignment using long-leg radiographs. While the procedure is generally effective at relieving symptoms, an accurate estimation of change in intraarticular contact pressures and contact surface area has not been developed. Using electromyography (EMG), Meyer et al. attempted to predict intraarticular contact pressures during gait patterns in a patient who had received a cruciate retaining force-measuring tibial prosthesis. Lundberg et al. used data from the Third Grand Challenge Competition to improve contact force predictions in total knee replacement. Mina et al. performed high tibial osteotomy on eight human cadaveric knees with osteochondral defects in the medial compartment. They determined that complete unloading of the medial compartment occurred at between 6° and 10° of valgus, and that contact pressure was similarly distributed between the medial and lateral compartments at alignments of 0° to 4° of valgus. In the current study, we hypothesised that it would be possible to predict the change in intra-articular pressures based on
Soft-tissue release plays an integral part in primary total knee arthroplasty by ‘balancing’ the knee. Asian patients often present late and consequently may have large deformities due to significant bone loss and contractures medially, and stretching of the lateral collateral ligament.
Deformity can be associated with significant bone loss, ligament laxity, soft-tissue contractures, distortion of long bone morphology, and
Intra-articular resection of bone with soft-tissue balancing and total knee replacement (TKR) has been described for the treatment of patients with severe osteoarthritis of the knee associated with an ipsilateral malunited femoral fracture. However, the extent to which deformity in the sagittal plane can be corrected has not been addressed. We treated 12 patients with severe arthritis of the knee and an
Deformity can be associated with significant bone loss, ligament laxity, soft-tissue contractures, distortion of long bone morphology, and
Fractures of the distal radius occurring in young adults are treated increasingly by open surgical techniques, partly because of concern that failure to restore the alignment of the fracture accurately may cause symptomatic post-traumatic osteoarthritis in future years. We reviewed 106 adults who had sustained a fracture of the distal radius between 1960 and 1968 and who were below the age of 40 years at the time of injury. We carried out a clinical and radiological assessment at a mean follow-up of 38 years (33 to 42). No patient had required a salvage procedure. While there was radiological evidence of post-traumatic osteoarthritis after an intra-articular fracture in 68% of patients (27 of 40), the disabilities of the arm, shoulder and hand (DASH) scores were not different from population norms, and function, as assessed by the Patient Evaluation Measure, was impaired by less than 10%. Ordinal logistic regression analysis showed a significant relationship between narrowing of the joint space and
Aims: In recent years, volar locking plates have increased in popularity for the treatment of displaced distal radial fractures. The angular stability of the screws help maintain reduction permitting early mobilisation. The aim of this study was to assess functional outcome using both subjective and objective methods. Methods: The study was a prospective cohort study. Over a 2 year period 110 patients with closed, displaced distal radial fractures were considered suitable for treatment with the distal radius volar locking plate. Of these, 51 patients were followed up for a full 12 months. One year post-operatively all patients were reviewed and both subjective and objective measurements made:. Subjective:. Pain – visual analogue scale (VAS) (0 = no pain, 10 = worst pain ever). Overall function – patients’ perception – VAS (0 = no function, 100 = full function). Objective: Strength – grip and pinch – measured objectively as a percentage of the uninjured side. Range of Motion – Flexion, extension, pronation and supination – measured objectively as percentages of the uninjured side. For the purpose of this analysis, the fractures were divided into intra- and
The majority of studies reporting sensitivity and specificity data for imaging modalities and physical examination tests for long head of biceps (LHB) tendon pathology use arthroscopy as the gold standard. However, there is little published data to validate this as an appropriate benchmark. The aim of this study was to determine the maximum length of the LHB tendon that can be seen at glenohumeral arthroscopy and whether it allows adequate visualisation of common sites of pathology. Seven female cadaveric specimens were studied. Mean age was 74 years (range 44–96 years). Each specimen underwent arthroscopy in lateral decubitus (LD) and beach chair (BC) positions. The LBH-tendon was tagged with a suture placed with a spinal needle marking the intra-articular length and the maximum excursions achieved using a hook and a grasper in both LD and BC positions. T-tests were used to compare data. The mean intra-articular and
Aims. Patients with a deformity of the hindfoot present a particular challenge when performing total knee arthroplasty (TKA). The literature contains little information about the relationship between TKA and hindfoot alignment. This systematic review aimed to determine from both clinical and radiological studies whether TKA would alter a preoperative hindfoot deformity and whether the outcome of TKA is affected by the presence of a postoperative hindfoot deformity. Methods. A systematic literature search was performed in the databases PubMed, EMBASE, Cochrane Library, and Web of Science. Search terms consisted of “total knee arthroplasty/replacement” combined with “hindfoot/ankle alignment”. Inclusion criteria were all English language studies analyzing the association between TKA and the alignment of the hindfoot, including the clinical or radiological outcomes. Exclusion criteria consisted of TKA performed with a concomitant
Limb deformity is common in patients presenting for knee arthroplasty, either related to asymmetrical wear patterns from the underlying arthritic process (intra-articular malalignment) or less often major
Objectives. The aim of this study was to use registry data to report and compare early patient outcomes following arthroscopic repair or debridement of the acetabular labrum. Methods. Data on adult patients who underwent arthroscopic labral debridement or repair between January 2012 and March 2019 was extracted from the UK Non-Arthroplasty Hip Registry dataset. Patients who underwent microfracture, osteophyte excision or a concurrent