Advertisement for orthosearch.org.uk
Results 1 - 32 of 32
Results per page:
Orthopaedic Proceedings
Vol. 88-B, Issue SUPP_I | Pages 92 - 93
1 Mar 2006
Ostermeier S Stein C Hurschler C Stukenborg-Colsman C
Full Access

Introduction: The amount of loading on the cruciate ligaments depends on the tension of the external muscular structures. In vivo studies using EMG have observed a proprioreceptive eccentric co-contraction of the hamstrings during isokinetic knee extension motion. This antagonistic co-contraction increases the quadriceps force necessary to produce the same extension moment on the knee, whereas the loading on the anterior cruciate ligament was measured to be reduced, with the loading on the posterior cruciate ligament to be increased. The objective of this study was thus to investigate the effect of simulated proprioreceptive co-contraction of the hamstrings muscles on quadriceps force, as well as on the relative loading on the cruciate ligament structures during knee extension under dynamic conditions and physiologic loads. Methods: Five fresh frozen knee specimen were tested in isokinetic extension. Bow shaped loading transducers were fixed in the medial fibres of the anterior (ACL) and posterior cruciate ligament (PCL). The test cycle simulated an isokinetic extension cycle from 120 degrees of flexion to full extension, a hydraulic cylinder thereby applied sufficient force to the quadriceps tendon in a closed-loop control cycle to produce a constant extension moment of 31 Nm about the knee. A second hydraulic cylinder simulated a 200 N co-contraction force of the hamstrings tendons. The loading on the ACL and PCL was first measured in the absence of hamstrings force, and subsequently under constant co-contractive flexion force. Results: In the absence of hamstring tension, the maximum quadriceps force was 1190 N ( SD 204 N) at 105 degrees of knee flexion. The loading on the ACL was reduced at larger flexion angles, the loading pattern of the PCL showed an inverse relationship with less loading at full extension. The maximum loading in the ACL was 161 N (SD138 N) and maximum tension in the PCL was 38.2 N (SD 34.9). With hamstring co-contraction, maximum quadriceps force increased 19.9 % ( SD 21.0% p= 0.33), maximum tension in the ACL decreased 71.9% (SD 74.3%, p=0.03), and maximum tension in the PCL increased 73.0% (SD 40.9%, p=0.03). Discussion: This experimental setup enabled direct in vitro measurement of ACL and PCL loading during simulated isokinetic extension motions. The loading on the ACL was dependent on the knee flexion angle. We observed that co-contraction of the hamstrings reduces loading on the anterior cruciate ligament without a significant concomitant increasing the quadriceps muscle force. Our results support the hypothesis that antagonistic co-contraction of the hamstrings during extension of the knee provides an important protective function. In contrast, loading in the posterior cruciate ligament increased during hamstring activation at higher knee flexion angles


The Journal of Bone & Joint Surgery British Volume
Vol. 75-B, Issue 1 | Pages 41 - 48
1 Jan 1993
O'Connor J

A computer-based model of the knee was used to study forces in the cruciate ligaments induced by co-contraction of the extensor and flexor muscles, in the absence of external loads. Ligament forces are required whenever the components of the muscle forces parallel to the tibial plateau do not balance. When the extending effect of quadriceps exactly balances the flexing effect of hamstrings, the horizontal components of the two muscle forces also balance only at the critical flexion angle of 22 degrees. The calculations show that co-contraction of the quadriceps and hamstring muscles loads the anterior cruciate ligament from full extension to 22 degrees of flexion and loads the posterior cruciate at higher flexion angles. In these two regions of flexion, the forward pull of the patellar tendon on the tibia is, respectively, greater than or less than the backward pull of hamstrings. Simultaneous quadriceps and gastrocnemius contraction loads the anterior cruciate over the entire flexion range. Simultaneous contraction of all three muscle groups can unload the cruciate ligaments entirely at flexion angles above 22 degrees. These results may help the design of rational regimes of rehabilitation after ligament injury or repair


The Bone & Joint Journal
Vol. 95-B, Issue 3 | Pages 348 - 353
1 Mar 2013
Metcalfe AJ Stewart C Postans N Dodds AL Holt CA Roberts AP

The aim of this study was to examine the loading of the other joints of the lower limb in patients with unilateral osteoarthritis (OA) of the knee. We recruited 20 patients with no other symptoms or deformity in the lower limbs from a consecutive cohort of patients awaiting knee replacement. Gait analysis and electromyographic recordings were performed to determine moments at both knees and hips, and contraction patterns in the medial and lateral quadriceps and hamstrings bilaterally. The speed of gait was reduced in the group with OA compared with the controls, but there were only minor differences in stance times between the limbs. Patients with OA of the knee had significant increases in adduction moment impulse at both knees and the contralateral hip (adjusted p-values: affected knee: p < 0.01, unaffected knee p = 0.048, contralateral hip p = 0.03), and significantly increased muscular co-contraction bilaterally compared with controls (all comparisons for co-contraction, p < 0.01). The other major weight-bearing joints are at risk from abnormal biomechanics in patients with unilateral OA of the knee. Cite this article: Bone Joint J 2013;95-B:348–53


The Bone & Joint Journal
Vol. 101-B, Issue 7 | Pages 867 - 871
1 Jul 2019
Wilcox M Brown H Johnson K Sinisi M Quick TJ

Aims

Improvements in the evaluation of outcomes following peripheral nerve injury are needed. Recent studies have identified muscle fatigue as an inevitable consequence of muscle reinnervation. This study aimed to quantify and characterize muscle fatigue within a standardized surgical model of muscle reinnervation.

Patients and Methods

This retrospective cohort study included 12 patients who underwent Oberlin nerve transfer in an attempt to restore flexion of the elbow following brachial plexus injury. There were ten men and two women with a mean age of 45.5 years (27 to 69). The mean follow-up was 58 months (28 to 100). Repeated and sustained isometric contractions of the elbow flexors were used to assess fatigability of reinnervated muscle. The strength of elbow flexion was measured using a static dynamometer (KgF) and surface electromyography (sEMG). Recordings were used to quantify and characterize fatigability of the reinnervated elbow flexor muscles compared with the uninjured contralateral side.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_34 | Pages 3 - 3
1 Dec 2013
Alta T de Toledo JM Loss JF Janssen TW Van der Scheer J Veeger D( Willems WJ
Full Access

Background:. It is not well known how different external loads influence shoulder kinematics and muscle activity in patients with shoulder prostheses. Study objective: define shoulder kinematics and determine the scapulothoracic contribution to total shoulder motion, in combination with shoulder muscle activity and the degree of co-contraction, of patients with total (TSA) and reverse shoulder arthroplasties (RSA) and healthy individuals during rehabilitation exercises using different loading conditions. Methods:. Shoulder motions (anteflexion and elevation in the scapular plane) of 17 patients (20 shoulders) with a TSA, 8 patients (9 shoulders) with a RSA and 15 healthy subjects were measured using anelectromagnetic tracking device. A force transducer recorded force signals during loaded conditions (without external load, 1 kg and elastic resistance). Electromyographic (EMG) activity of the deltoid (anterior, middle, posterior parts), latissimus dorsi, pectoralis major (clavicular and sternal parts), teres major and serratus anterior was recorded and the degree of co-contraction calculated. Results:. The scapula contributed more to movement of the arm in subjects with prostheses compared to healthy subjects and during loaded versus unloaded tasks. Glenohumeral elevation angles during anteflexion were significantly higher in the TSA than in the RSA group. Higher activity of the middle and posterior deltoid was found in the TSA group compared to healthy subjects and for the pectoralis major (sternal part) in the RSA group compared to TSA and healthy subjects. For all muscles, except the serratus anterior, activity was lower for unloaded tasks compared to 1 kg dumbbell and elastic band resistance. No main effect of group or load for degree of co-contraction was detected in both exercises. Conclusions:. Differences in contribution of the scapula to total shoulder motion between patients with different types of arthroplasties were not significant, but differed both compared to healthy subjects. Scapular kinematics of patients with shoulder arthroplasties were influenced by implementation of external loads, however, not by the type of load. There were no differences in muscle activity and degree of co-contraction between patient groups


Orthopaedic Proceedings
Vol. 91-B, Issue SUPP_II | Pages 241 - 242
1 May 2009
Kean C Birmingham T Garland J Giffin JR Jenkyn TR Jones IC
Full Access

Previous research suggests knee joint moments and muscle activity during walking are altered in patients with anterior cruciate ligament (ACL) deficiency and in patients with medial compartment knee osteoarthritis (OA). The objective of this study was to compare knee joint flexion and adduction moments and the extent of quadriceps-hamstring muscle co-contraction before and one year after combined simultaneous ACL reconstruction and high tibial osteotomy (HTO). Eighteen patients (three females, fifteen males; age = 40 ± 8 yrs.; BMI = 28.8 ± 5.77) with ACL deficiency and OA affecting primarily the medial compartment of the knee underwent ACL reconstruction (hamstring autograft) and medial opening wedge HTO procedures during a single operation. All patients completed pre-operative and one-year postoperative quantitative gait assessments. Three-dimensional kinetic and kinematic data were collected during self-paced walking and used to calculate the peak external flexion and adduction moments about the knee. Electromyographic (EMG) activity was collected from the hamstrings and quadriceps and used to calculate the co-contraction ratio. Peak moments and co-contraction ratios were compared pre and postoperatively using paired t-tests. The peak knee flexion moment decreased from 2.31 ± 1.14 to 1.33 ± 0.73 %BW*ht (p=0.001); mean decrease = 0.98 %BW*ht (95%CI: 0.49–1.47). The peak knee adduction moment decreased from 2.81 ± 0.62 to 1.69 ± 0.61 %BW*ht (p< 0.001); mean decrease = 1.12 %BW*ht (95% CI: 0.80–1.43). The quadriceps-hamstring co-contraction ratio decreased from 0.82 ± 0.14 to 0.72 ± 0.18 (p=0.056); mean decrease = 0.10 (95% CI: −0.003 – 0.21). The present findings suggest that combined simultaneous ACL reconstruction and HTO significantly decreases knee flexion and adduction moments during walking. Although the present findings suggest that the quadriceps-hamstring co-contraction ratio also decreases, future research with more patients is required to confidently evaluate potential changes in muscle activity. These findings are consistent with an overall reduction in dynamic knee joint load


Orthopaedic Proceedings
Vol. 91-B, Issue SUPP_I | Pages 47 - 47
1 Mar 2009
Benedetti M Catani F Berti L Mariani G Giannini S
Full Access

Functional outcome in Total Knee Arthroplasty (TKA), as measured by means of gait analysis for kinematics, kinetics, and muscular activity around the knee shows abnormalities even in patients with excellent clinical outcome. Knee flexion during loading response phase is reduced, accompanied by co-contraction of knee extensors and flexors. Such subtle failure in knee performance during loading absorption was claimed to depend on several factors: quadriceps weakness, prosthetic design, pre-surgical pattern, proprioception disruption. It was supposed to damage the implant in time. The lack of the anterior cruciate legament seems to play a major role in the loss of control of the roll back pattern of the condyles on the tibial plateau in TKA patients. Previous works on unicondylar knee artrhoplasty (UKA) demonstrated better gait performance when anterior cruciate ligament was preserved allowing the patients to maintain normal quadriceps mechanics. The aim of the present work is to evaluate UKA patients knee function during gait compared to TKA with the hypothesis that UKA ensures more physiological knee loading response pattern of movement and a more phasic muscular activation, thus reducing the risk of failure. Twenty patients with Oxford/Exactech UKA (mean age 70 (SD 7.9), mean follow-up 2 years) were evaluated by means of a Vicon 612-8 cameras system, two Kistler forceplates and Telemg respectively for knee 3D kinematics, kinetics and muscular activity. Data of UKA were compared to those of a control population of ten healthy subjects and ten patients with TKA matched for age and follow up. Mean UKA-IKS score at the time of gait analysis was 90. Time-distance parameters evidenced a slight slow gait with reduced stride length and cadence and a symmetric longer stance phase with respect to TKA and controls. Knee kinematics on the sagittal plane showed knee flex-ion during loading response very close to controls and a reduced but phasic pattern of joint moments on the sagittal plane. Adduction moment at the knee was normal. EMG showed controversy results as some patients had a regular pattern of activation of rectus femoris and hamstrings without co-contraction whereas other patients had co-contraction. These preliminary results indicate that UKA allows in most patients a quite normal knee kinematics and kinetics, although some abnormalities persist in quadriceps activation. Further research is required to understand these findings assessing other factors which could influence quadriceps activity such as age, proprioception, and muscular strength


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XVIII | Pages 41 - 41
1 May 2012
Metcalfe A Stewart C Postans N Dodds A Smith H Holt C Roberts A
Full Access

Introduction. Patients with knee osteoarthritis (OA) often tell us that they put extra load on the joints of the opposite leg as they walk. Multiple joint OA is common and has previously been related to gait changes due to hip OA (Shakoor et al 2002). The aim of this study was to determine whether patients with medial compartment knee OA have abnormal biomechanics of the unaffected knee and both hips during normal level gait. Methods. Twenty patients (11 male, 9 female), with severe medial compartment knee OA and no other joint pain were recruited. The control group comprised 20 adults without musculoskeletal pain. Patients were reviewed, x-rays were examined and WOMAC and Oxford knee scores were completed. A 12 camera Vicon (Vicon, Oxford) system was used to collect kinematic data (100Hz) on level walking and the ground reaction force was recorded using three AMTI force plates (1000Hz). Surface electrodes were placed over medial and lateral quadriceps and hamstrings bilaterally to record EMG data (1000Hz). Kinematics and kinetics were calculated using the Vicon ‘plug-in-gait’ model. A co-contraction index was calculated for the EMG signals on each side of the knee, representing the magnitude of the combined readings relative to their maximum contraction during the gait cycle. Statistical comparisons were performed using t-tests with Bonferroni's correction for two variables and ANOVA for more than two variables (SPSS v16). Results. The mean age of the patients was 69 (SD 8.8). Mean gait speed was 0.95m/s (study group) and 1.44m/s (control group). Peak adduction moments for the OA group [OA Knee; Unaffected Knee; Ipsilateral Hip; Contralateral Hip; in Nm/Kg(±95% CI)] were: 0.55(0.06); 0.47(0.06); 0.73(0.09); 0.73(0.08). Control values for peak moments were 0.64 (0.06) for the knee and 0.81(0.07) at the hip. Mid-stance adduction moments for the OA group (listed as before) were: 0.44(0.08); 0.33(0.06); 0.64(0.06); 0.61(0.08). Control values for mid-stance moments were 0.14(0.03) and 0.40(0.04). [OA group vs. Controls: p=NS for peak moments at all 4 joints; p<0.01 for mid-stance moments at all joints]. Co-contraction indices for hamstrings and quads, [OA knee medial; and lateral; unaffected knee medial; and lateral; control medial; and lateral; 0<X. Discussion. Although the affected subjects all had only single joint OA, abnormal moments were present in the hips and knees of both legs during normal level gait, despite the reduced gait speed of the OA cohort. Abnormal hamstring and quadriceps co-contraction occurs bilaterally in patient with single joint OA. Increased trunk sway is a recognised compensation in knee OA and may be the cause of the abnormal hip and contra-lateral knee loading found in this study. Further investigation is warranted and may lead to improvements in the long term outcome for these patients. Acknowledgement. The study was funded by the North Wales NHS Trust


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_1 | Pages 56 - 56
1 Jan 2017
Belvedere C Ensini A Tamarri S Ortolani M Leardini A
Full Access

In total knee replacement (TKR), neutral mechanical alignment (NMA) is targeted in prosthetic component implantation. A novel implantation approach, referred to as kinematic alignment (KA), has been recently proposed (Eckhoff et al. 2005). This is based on the pre-arthritic lower limb alignment which is reconstructed using suitable image-based techniques, and is claimed to allow better soft-tissue balance (Eckhoff et al. 2005) and restoration of physiological joint function. Patient-specific instrumentation (PSI) introduced in TKR to execute personalized prosthesis component implantation are used for KA. The aim of this study was to report knee kinematics and electromyography (EMG) for a number lower limb muscles from two TKR patient groups, i.e. operated according to NMA via conventional instrumentation, or according to KA via PSI. 20 patients affected by primary gonarthrosis were implanted with a cruciate-retaining fixed-bearing prosthesis with patella resurfacing (Triathlon® by Stryker®, Kalamazoo, MI-USA). 17 of these patients, i.e. 11 operated targeting NMA (group A) via convention instrumentation and 6 targeting KA (group B) via PSI (ShapeMatch® by Stryker®, Kalamazoo, MI-USA), were assessed clinically using the International Knee Society Scoring (IKSS) System and biomechanically at 6-month follow-up. Knee kinematics during stair-climbing, chair-rising and extension-against-gravity was analysed by means of 3D video-fluoroscopy (CAT® Medical System, Monterotondo, Italy) synchronized with 4-channel EMG analysis (EMG Mate, Cometa®, Milan, Italy) of the main knee ad/abductor and flexor/extensor muscles. Knee joint motion was calculated in terms of flex/extension (FE), ad/abduction (AA), and internal/external rotation (IE), together with axial rotation of condyle contact point line (CLR). Postoperative knee and functional IKSS scores in group A were 78±20 and 80±23, worse than in group B, respectively 91±12 and 90±15. Knee motion patterns were much more consistent over patients in group B than A. In both groups, normal ranges were found for FE, IE and AA, the latter being generally smaller than 3°. Average IE ranges in the three motor tasks were respectively 8.2°±3.2°, 10.1°±3.9° and 7.9°±4.0° in group A, and 6.6°±4.0°, 10.5°±2.5° and 11.0°±3.9° in group B. Relevant CLRs were 8.2°±3.2°, 10.2°±3.7° and 8.8°±5.3° in group A, and 7.3°±3.5°, 12.6°±2.6° and 12.5°±4.2° in group B. EMG analysis revealed prolonged activation of the medial/lateral vasti muscles in group A. Such muscle co-contraction was not generally observed in all patients in group B, this perhaps proving more stability in the knee replaced following the KA approach. These results reveal that KA results in better function than NMA in TKR. Though small differences were observed between groups, the higher data consistency and the less prolonged muscle activations detected using KA support indirectly the claim of a more natural knee soft tissue balance. References


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_5 | Pages 118 - 118
1 Mar 2017
Ro J Kim C Kim J Yoo O
Full Access

Introduction. Total knee arthroplasty (TKA) is a well proven surgical procedure. Squat and gait motions are common activities in daily life. However, squat motion is known as most dissatisfying motion in activities in daily life after total knee arthroplasty (TKA). Dissatisfaction after TKA might refer to muscle co-contraction between quadriceps and hamstrings. The purposed of this study was to develop squat and gait simulation model and analyses the contact mechanics and quadriceps and hamstring muscle stability. We hypothesized that squat model shows larger contact forces and lower hamstring to quadriceps force ratio than gait model. Materials and Methods. Squat motion and gait model were simulated in musculoskeletal simulation software (AnyBody Modeling System, AnyBody Technology, Denmark). Subject-specific bone models used in the simulation were reconstructed from CT images by Mimics (Materialize, Belgium). The lower extremity model was constructed with pelvis, femur, tibia, foot segments and total knee replacement components: femoral component, tibial insert, tibial tray, and patella component [Fig.1]. The muscle model was consisted of 160 muscle elements. The TKR components used in this study are PS-type LOSPA Primary Knee System (Corentec Co., Ltd, Republic of Korea). Force-dependent kinematics method was used in the simulation. The model was simulated to squat from 15° to 100° knee flexion, in 100 frames. Gait simulation model was based on motion capture and force-plate system. Motion capture and force-plate data were from grand challenge competition dataset. Results / Discussion. Patellofemoral contact forces ranged from 0.18 to 3.78 percent body weight (%BW) and from 0.00 to 1.36 %BW during squat motion and gait cycle, respectively. Patellofemoral contact forces calculated at 30°, 60°, and 90° flexion during squat motion were 0.53, 1.93, and 3.22 %BW, respectively. Wallace et al. also reported patellofemoral contact forces at 30°, 60°, and 90° flexion, which were 0.31, 1.33, 2.45 %BW during squat motion. Our results showed similar results from other studies, however the squat model overestimated the patellofemoral contact forces. Contact stiffness in the simulation model might affected the overestimated contact forces. Hamstring to quadriceps force ratio ranged from 0.32 to 1.88 for squat model, and from 0.00 to 2.54 for gait model. As our hypothesis, squat motion showed larger patellofemoral contact forces. Also, mean hamstring to quadriceps force ratio of squat model were about half than the mean hamstring to quadriceps force ratio of gait model. From the results, possibility exists that unbalanced force of quadriceps and hamstring can affect dissatisfaction after TKA while squat motion is the most dissatisfying motion after TKA. However, muscle stability is not the only factor that can affect dissatisfaction after TKA. In future study, more biomechanical parameters should be evaluated to find meaningful dissatisfying factor after TKA. Conclusion. In conclusion, TKA musculoskeletal models of squat and gait motion were constructed and patellofemoral contact force / hamstring to quadriceps force ratio were evaluated. Patellofemoral mechanics were validated by comparison of previous study. Additional studies are needed to find dissatisfying factor after TKA


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_6 | Pages 100 - 100
1 Mar 2017
Wimmer M Simon J Kawecki R Della Valle C
Full Access

Introduction. Preservation of the anterior cruciate ligament (ACL), along with the posterior cruciate ligament, is believed to improve functional outcomes in total knee replacement (TKR). The purpose of this study was to examine gait differences and muscle activation levels between ACL sacrificing (ACL-S) and bicruciate retaining (BCR) TKR subjects during level walking, downhill walking, and stair climbing. Methods. Ten ACL-S (Vanguard CR) (69±8 yrs, 28.7±4.7 kg/m2) and eleven BCR (Vanguard XP, Zimmer-Biomet) (63±11 yrs, 31.0±7.6 kg/m2) subjects participated in this IRB approved study. Except for the condition of the ACL, both TKR designs were similar. Subjects were tested 8–14 months post-op in a motion analysis lab using a point cluster marker set and surface electrodes applied to the Vastus Medialis Oblique (VMO), Rectus Femoris (RF), Biceps Femoris (BF) and Semitendinosus (ST). 3D motion and force data and electromyography (EMG) data were collected simultaneously. Subjects were instructed to walk at a comfortable walking speed across a walkway, down a 12.5% downhill slope, and up a staircase. Five trials per activity were collected. Knee kinematics and kinetics were analyzed using BioMove (Stanford, Stanford, CA). The EMG dataset underwent full-wave rectification and was smoothed using a 300ms RMS window. Gait cycle was time normalized to 100%; relative voluntary contraction (RVC) was calculated by dividing the average activation during downhill walking by the maximum EMG value during level walking and multiplying by 100%. Results. There were no significant kinematic or kinetic differences between implant groups for level walking (p≥0.19). Both groups walked at 1.1 m/s on average during level and approximately 0.1 m/s slower during downhill walking, with no differences in speed (p= 0.91 and 0.77, respectively). For both ACL-S and BCR groups, gait changes from level to downhill walking were similar. For downhill walking, ACL-S subjects were significantly more variable (p<0.001) over the gait cycle for all measured kinematics and kinetics. During both downhill walking and stair climbing, the ACL-S group showed an external peak abduction moment (Fig. 1) significantly greater than that of the BCR group (p=0.05, 0.01). Also during stair climbing, ACL-S subjects showed trending higher peak knee adduction moments (p=0.14) and a more pronounced internal/external rotation pattern (Fig. 2) than BCR subjects. Since no peak kinematic/kinetic differences between groups during level walking exist, the mean maximum muscle activation from level walking was used for RVC normalization for other activities. On average, BCR subjects had lower maximum RVCs during downhill walking than the ACL-S subjects. Effect sizes were large for RF (d=0.94), ST (d=0.88), and VMO (d=1.21), the latter being borderline significant (p=0.05). Discussion. Previous studies on the natural knee have established that the ACL contains mechanoreceptors that improve stability of the knee joint. In this study, BCR subjects show less variable gait measures than subjects with traditional posterior cruciate retaining (ACL-S) TKR, possibly indicating more controlled contact kinematics. In addition, EMG results suggest lower muscle co-contraction during downhill walking, also implying greater knee stability in the BCR group. These results are preliminary and more subjects are needed for definite conclusions


Bone & Joint Research
Vol. 11, Issue 10 | Pages 739 - 750
4 Oct 2022
Shu L Abe N Li S Sugita N

Aims

To fully quantify the effect of posterior tibial slope (PTS) angles on joint kinematics and contact mechanics of intact and anterior cruciate ligament-deficient (ACLD) knees during the gait cycle.

Methods

In this controlled laboratory study, we developed an original multiscale subject-specific finite element musculoskeletal framework model and integrated it with the tibiofemoral and patellofemoral joints with high-fidelity joint motion representations, to investigate the effects of 2.5° increases in PTS angles on joint dynamics and contact mechanics during the gait cycle.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXI | Pages 41 - 41
1 May 2012
R. G J. P T. Y M. G F. M
Full Access

Children with diplegic cerebral palsy develop progressive musculoskeletal deformities with deterioration in their gait. Multilevel surgery is a well-established treatment modality involving a combination of soft tissue lengthening and correction of bony deformities. At Bristol Royal Children's Hospital we have identified a cohort of 45 children with diplegic cerebral palsy who have undergone multilevel surgery. Video gait analysis had been performed pre-operatively and three years post-operatively. We utilised the Edinburgh Visual Gait Score (EVGS). [1]. , a validated system that allows direct comparison with gait videos taken during different periods of the patient's treatment. Seventeen measurements are taken per limb at each stage. The patients were also categorised according to the Functional Walking Score (FWS) . [2]. that assesses their level of independence. Post-operative results demonstrate a significant improvement in gait score on both the EVGS and FWS. Patients whose gait was more severely affected prior to surgery had the greatest improvement in mobility and functional scores. Patients consistently had significant improvements in hip and knee extension in stance phase, with more modest improvement in knee flexion in swing with persistent co-contraction. Both initial contact and heel lift were consistently abnormal pre-operatively, but few patients achieved a heel strike and normal heel lift post-operatively. We are proceeding with a long-term follow-up of this cohort of patients at 15 years following surgery. The combination of using detailed video gait analysis with functional assessment is a valuable tool in retrospective assessment of patients' outcome following surgery. It gives a quantitative evaluation of progression over time as well as allowing comparison with a cohort of patients to estimate the future level of functional independence


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_III | Pages 359 - 359
1 Jul 2011
Metaxiotis D Nikodelis T Moscha D Milonas C Kiriakidis A
Full Access

The objective and dynamic documentation of the knee kinematics in ambulatory children with spastic cerebral palsy and the examination of possible causes of differences when compared to normals. 17 ambulatory patients with an average age of 10,5 years (6–17 years) with cerebral palsy, spastic diplegia where examined clinically including Duncan-Ely test. They were also examined with 3-D instrumented gait analysis. The Elite system with six cameras was used and the knee kinematics in the sagittal plane was recorded. Almost all patients (16/17) had a positive Duncan-Ely test during clinical examination. The knee kinematics in the sagittal plane showed that in 20/34 knees the range of motion was decreased compared to normal values. In 30/34 knees there was a delayed maximum knee flexion in swing phase and in 16/34 knees the amplitude of the maximum knee flexion was decreased compared to normals. Patients with severe crouch or mild rectus spasticity had almost normal knee flexion. Foot clearance in swing phase is one of the basic prerequisites of normal gait. Patients with spastic cerebral palsy who are able to walk have an impaired foot clearance because of the pathological action of the rectus femoris. In our study the majority of the patients with clinically confirmed rectus spasticity had decreased timing and amplitude of max. knee flexion in swing. In patients with severe co-contraction of the knee flexors and extensors max. knee flexion within normal range. Therefore it should not be considered as the only evaluation parameter in rectus femoris spasticity


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXIX | Pages 72 - 72
1 Jul 2012
Metcalfe A Stewart C Postans N Barlow D Whatling G Holt C Roberts A
Full Access

Introduction. Patients with knee osteoarthritis frequently complain that they develop pain in other joints due to over-loading during gait. However, there have been no previous studies examining the effect of knee arthritis on the other weight bearing joints. The aim of this study was to examine the loading of the hips and contra-lateral knee during gait in a cohort of patients pre- and post knee replacement. Methods. Twenty patients with single joint osteoarthritis awaiting knee replacement and 20 healthy volunteers were recruited. Gait analysis during level gait and at self selected speed was performed using a 12 camera Vicon motion analysis system. The ground reaction force was collected using EMG electrodes attached to the medial and lateral hamstrings and quadriceps bilaterally. Patients were invited to return 12 months post-operatively. Data was analysed using the Vicon plug-in-gait model and statistical testing was performed with SPSS v16.0 using ANCOVA to account for gait speed. Results. The mean age of the patients was 69 (range 53-82) and the controls was 70 (range 60-83). Mid-stance moments and knee adduction impulses were elevated at both hips and both knees in patients compared to normal individuals (Impulses: OA Knee=1.87Nms; opposite knee=1.46Nms; controls=0.86Nms; p<0.01) whilst peak moments were not significantly different. Muscular co-contraction was elevated in both knees compared to normal (p<0.01). Ten patients returned for follow up. Correction of varus resulted in improvements in moments at the replaced knee however recovery of moments in the other joints was variable and dependant on alignment, gait speed and their ability to mobilise their centre of mass. Conclusion. Patients with single joint knee osteoarthritis have abnormal loading of both knees and both hips, potentially leading to further disease and disability. Recovery following knee replacement is variable and dependant on limb alignment and the patient's functional recovery


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_11 | Pages 94 - 94
1 Jul 2014
Gauthier P Benoit D
Full Access

Summary. This study describes the use of a quasi-static, 6DOF knee loading simulator using cadaveric specimens. Muscle force profiles yield repeatable results. Intra-articular pressure and contact area are dependent on loading condition and ACL integrity. Introduction. Abnormal contact mechanics of the tibiofemoral joint is believed to influence the development and progression of joint derangements. As such, understanding the factors that regulate joint stability may provide insight into the underlying injury mechanisms. Muscle action is believed to be the most important factor since it is the only dynamic regulator of joint stability. Furthermore, abnormal muscle control has been experimentally linked to the development of OA [Herzog, 2007] and in vivo ACL strain [Fleming, 2001]. However, the individual contributions to knee joint contact mechanics remain unclear. Thus, the purpose of this study was to examine the effects of individual muscle contributions on the tibiofemoral contact mechanics using an in-vitro experimental protocol. Methodology. Contact mechanics of 6 fresh frozen cadaver knee specimens were evaluated using the UofO Oxford knee loading device. Various combinations of quadriceps-hamstring co-contraction ratios were applied to the knee while it was “suspended” between the hip and foot components of the device. Loads of six muscle groups were computed using a hill-type musculoskeletal model [Buchanan, 2004]. Simulated ground reaction forces were also applied to the knee to represent force profiles of weight acceptance during gait as it has been shown to produce peak knee joint force in the gait cycle [Shelburne et al., 2006]. For respective medial and lateral joint compartments, the mean contact area (MC-CA and LC-CA), mean contact pressure (MC-CP and LC-CP), peak pressure (MC-PP and LC-PP), and centre of force displacement (MC-COFD and LC-COFD) were determined using a 4011 piezoelectric sensor form Tekscan (Tekscan Inc. Boston, MA). Additionally, the ACL was resected and measurements were repeated. Pearson correlations (r) examined the reliability of measurements as well as the effect an ACL transection on articular loads. Results. Positive correlations were computed for the following: COFD with intact ACL (r=0.99), COFD with resected ACL (r=0.82), MC-COFD pre vs. post ACL- resection (0.91). Furthermore, preliminary results indicated a positive correlation between MC-CA and ACL integrity (r=0.97). Discussion. The repeatability of the measured dependant variables validates the use of the knee-loading device. Interestingly, contact mechanics are more variable post ACL resection for a given muscle loading condition, indicating a decrease in knee joint stability. Also, the COFD is dependent on the different ratios of muscle loads applied to the knee, which demonstrates the importance of muscle action to the modulation of contact forces


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_34 | Pages 350 - 350
1 Dec 2013
Hirokawa S Fukunaga M
Full Access

Knowledge of joint kinematics in the lower limb is important for understanding joint injuries and diseases and evaluating treatment outcomes. However, limited information is available about the joint kinematics required for high flexion activities necessary for floor sitting life style. In this study, the hip and knee joint kinematics of ten healthy male and ten healthy female subjects were investigated using an electromagnetic motion tracking system. We measured the hip and knee joints' functions moving into 1) kneeling on knees with legs parallel without using arms, 2) kneeling on knees with legs parallel with using arms, 3) kneeling on knees with one foot forward without using arms, 4) cross-legged sitting, 5) kneeling with legs to the side, 6) sitting with legs stretched out, and 7) deep squatting, and moving out of the above seven conditions. Conditions 1) through 3) were Japanese seiza style. On conditions 4) through 7), arms were not used. We further measured the functions of putting on and taking off a sock under such conditions as 8) with standing position and 9) sitting position (Fig 1). Here special attention was paid for flexion and extension motion. The data were used to produce the pattern of joint angulation against the percentage of the cycle for each individual conducting each activity. The kinematic curves were split into 3 phases: moving into the rest position, the rest position and out of the rest position. It should be noted that the moving into and the rest phases were split at the moment when the peak value was determined during the moving into phase. Thus the initiation of the rest phase on the curve was not coinciding with the moment the subject reached at the rest position. This was necessary in order not for the mean kinematic curve to become too dull in shape. Same was true when the end of rest phase was determined. The maximum hip and knee joint angles during the cycle were determined. Further a relationship between the hip and knee joint excursions were investigated. The results indicated condition 8) requires the maximum flexion angles to the hip among all conditions, 157.5 ± 20.4° and condition 3) to the knee joint, 157.1 ± 10.0° respectively (Fig 2). The results also indicated in many activities, the maximum joint angles were recorded not during the rest phase but during the moving into or out of phase. In any conditions even including donning on and off a sock, a strong relationship was found between the hip and knee joints motion (Fig 3), indicating the bi-articular muscles' co-contraction during the sit to stand activities. The data presented in this study will increase the knowledge of high-flexion needs especially in non-Western cultures and provide an initial characterization of the prosthesis kinematics in high flexion


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_11 | Pages 166 - 166
1 Jul 2014
Flaxman T Smith A Benoit D
Full Access

Summary Statement. Using a weight-bearing force control task, age-related changes in muscle action were observed in osteoarthritic subjects, however, greater activation of rectus femoris and medial hamstring muscles in the OA group compared to control indicates greater cocontraction and varied stabilisation strategies. Introduction. Osteoarthritis (OA) is the most debilitating condition among older adults. OA is thought to be mechanically driven by altering the stabilising integrity of the joint. The main contributor to knee joint stability is that of muscular contraction. In cases where the history of a traumatic knee joint injury is not a causal factor, a change in muscle function, resulting in reduced strength and force control in believed to induce OA development and progression. Since age is also a determining factor of OA, the purpose of this study was to investigate the muscle activation patterns of young healthy adults (YC), older healthy adults (OC), and adults with OA during a standing isometric force control task. Patients & Methods. A force matching protocol was used to evaluate muscle activation patterns of 41 YC (23.1±1.9 years of age) 18 OC (59.7±5.14 years), and 19 OA (63.5±8.1 years). Subjects stood with their leg of interest fixed to a force platform and modulated ground reaction forces while exposing equal body weight to each leg. Surface electromyography (EMG) of 8 muscles that cross the knee joint, kinetics and kinematics were recorded while subjects generated 30% of their maximal force in 12 different directions, corresponding to various combinations of medial-lateral-anterior-posterior ground reaction forces. Processed EMG was normalised to previously recorded maximum voluntary isometric contraction (MVIC) and ensemble averaged into group means for each loading direction. Muscle activation patterns were displayed in EMG polar plots and were quantified with symmetry analyses, mean activation levels (X. EMG. ), directions (Φ), and specificity indices (SI). Group differences were tested with independent T-tests at the p<0.05 level. Results. Muscle activation patterns were similar between groups (i.e. symmetry and Φ). However, X. EMG. of 7 muscles was significantly greater in both the OA and OC groups compared to YC. OA group also demonstrated significantly greater X. EMG. in the rectus femoris and tensor fascia lata as well as lower SI in semitendinosus hamstrings compared to OC. Discussion/Conclusion. Our results indicate that regardless of loading direction, both OC and OA groups have greater levels of muscle co-contraction than YC. This is suggested to be an adaptive response to age-related changes in muscle strength and force control. Since individuals with OA have reduced muscle strength and force control compared to age-matched controls, our results suggest that the OA group's greater, less specific activation of knee joint muscles relative to the OC is this “stiffening” response adapted by the OA group, however, to an extent that may expose the joint to detrimental loading conditions, contributing to the progression of OA. Further investigation regarding age-related neuromuscular changes and their influence on joint loading conditions and development of OA is warranted


Orthopaedic Proceedings
Vol. 91-B, Issue SUPP_II | Pages 220 - 220
1 May 2009
Jenkyn T Bhatnagar T Birmingham T
Full Access

Create an optimization model of the internal structure of the knee joint to quantify the correlation between external knee adduction moment (M[add]) during gait with the medial-to-lateral ratio of compartment loading (MLR). Patients were examined the week before, and six months after, surgical knee joint realigment with a high tibial osteotomy (HTO). Thirty patients (six females, twenty-four males; age = 50.0 ± 9.4 yrs.; BMI = 30.0±2.8) with clinically diagnosed OA primarily affecting the medial compartment of the knee underwent a medial opening wedge HTO. Walking gait analysis was performed immediately pre-surgery and at six months post-surgery using optical motion analysis (eight Eagle camera EvaRT system, Motion Analysis Corp, Santa Rosa, CA, USA) and floor-mounted force plate (OR6, AMTI, Watertown, MA, USA). External joint kinetics were calculated using inverse dynamics. Kinematic and force plate data served as input for the internal knee joint model. The anatomical geometry was generic but scaled to patient height and knee alignment. Included were four ligaments (ACL, PCL, LCL, MCL), two contact surfaces (medial and lateral) and eleven muscles (quadriceps, hamstrings, gracilis, sartorius, popliteus and gatrocnemius). A loading solution was found to satisfy mechanical equilibrium and minimise the sum of squares of all structural loads. Output was the ratio of medial-to-lateral compartment compression (MLR). Paired t-tests compared M[add] pre-op versus post-op and MLR pre-op versus post-op. A Pearson R2 coefficient of determination was calculated correlating M[add] to MLR for the pre-operative condition. Peak M[add] decreased from 2.53 ± 1.32 to 1.63 ± 0.81 [%body weight*ht] (p< 0.001). The peak MLR decreased from 2.63 ± 1.08 to 1.52 ± 0.56 [unit-less] (p< 0.001). There was a moderate correlation between M[add] and MLR with the Pearson R2=0.457 (p=0.014). These results suggest that adduction moment is an acceptable proxy for quantifying the internal compressive loading in the knee. Even without considering muscle loading and possible co-contraction of antagonists, adduction moment explains nearly half of the variance in the internal loading of the knee joint compartments. However, further research is required with a larger sample size to increase confidence in this proxy measure in a clinical setting


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXV | Pages 37 - 37
1 Jun 2012
Mizu-Uchi H Flores-Hernandez C Colwell C Steklov N Matsuda S Iwamoto Y D'Lima D
Full Access

INTRODUCTION. Knee contact force during activities after total knee arthroplasty (TKA) is very important, since it directly affects component wear and implant loosening. While several computational models have predicted knee contact force, the reports vary widely based on the type of modeling approach and the assumptions made in the model. The knee is a complex joint, with three compartments of which stability is governed primarily by soft tissues. Multiple muscles control knee motion with antagonistic co-contraction and redundant actions, which adds to the difficulty of accurate dynamic modeling. For accurate clinically relevant predictions a subject-specific approach is necessary to account for inter-patient variability. METHODS. Data were collected from 3 patients who received custom TKA tibial prostheses instrumented with force transducers and a telemetry system. Knee contact forces were measured during squatting, which was performed up to a knee flexion angle that was possible without discomfort (range, 80–120°). Skin marker-based video motion analysis was used to record knee kinematics. Preoperative CT scans were reconstructed to extract tibiofemoral bone geometry using MIMICS (Materialise, Belgium). Subject-specific musculoskeletal models of dynamic squatting were generated in a commercial software program (LifeMOD, LifeModeler, USA). Contact was modeled between tibiofemoral and patellofemoral articular surfaces and between the quadriceps and trochlear groove to simulate tendon wrapping. Knee ligaments were modeled with nonlinear springs: the attachments of these ligaments were adjusted to subject-specific anatomic landmarks and material properties were assigned from published reports. RESULTS. Total measured peak ground reaction force was 0.9–1.1 xBW (times of bodyweight) and measured peak knee contact force was 2.2 (±0.2) xBW during squatting. Model predicted peak tibiofemoral contact forces were within the cycle-to-cycle variations for each subject. Model predicted peak patellofemoral contact forces were 0.9–1.1 xBW and peak quadriceps forces were 1.3–1.6 xBW. Mean peak ligament tensions were 55.5 ± 8.8 N for the MCL and 47.1 ± 10.4 N for the LCL. DISCUSSION. Small differences between predicted and measured forces were likely due to the complexity of the squatting activity, the inherent error in skin marker-based motion capture, and the fact that muscle force was computed from muscle shortening history. Trunk flexion significantly affected the contact force, especially at higher knee flexion angles. Trunk flexion reduced the external flexion moment at the knee leading to reduced quadriceps force and therefore reduced tibiofemoral contact force. Peak patellofemoral contact forces and quadriceps muscle forces were also lower than previously reported. Although others have reported on hamstring muscle activity during the squat, hamstring forces were low in our models in qualitative agreement with the EMG data that we recorded during squatting. The lack of significant hamstring activity may explain the lower net tibiofemoral contact forces. This model would be very useful tool to predict the effect of surgical techniques on contact forces. Such a model could be used for implant design development to enhance knee function and to predict forces generated during other activities. Finally a subject-specific model could be useful for predicting clinical outcomes


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXV | Pages 2 - 2
1 Jun 2012
Acker S Kutzner I Bergmann G Deluzio K Wyss U
Full Access

Accurate in vivo knee joint contact forces are required for joint simulator protocols and finite element models during the development and testing of total knee replacements (Varadarajan et al., 2008.) More accurate knowledge of knee joint contact forces during high flexion activities may lead to safer high flexion implant designs, better understanding of wear mechanisms, and prevention of complications such as aseptic loosening (Komistek et al., 2005.) High flexion is essential for lifestyle and cultural activities in the developing world, as well as in Western cultures, including ground-level tasks and chores, prayer, leisure, and toileting (Hemmerich et al., 2006.) In vivo tibial loads have been reported while kneeling; but only while the subject was at rest in the kneeling position (Zhao et al., 2007), meaning that the loads were submaximal due to muscle relaxation and thigh-calf contact support. The objective of this study was to report the in vivo loads experienced during high flexion activities and to determine how closely the measured axial joint contact forces can be estimated using a simple, non-invasive model. It provides unique data to better interpret non-invasively determined joint-contact forces, as well as directly measured tiobiofemoral joint contact force data for two subjects. Two subjects with instrumented tibial implants performed kneeling and deep knee bend activities. Two sets of trials were carried out for each activity. During the first set, an electromagnetic tracking system and two force plates were used to record lower limb kinematics and ground reaction forces under the foot and under the knee when it was on the ground. In the second set, three-dimensional joint contact forces were directly measured in vivo via instrumented tibial implants (Heinlein et al., 2007.) The measured axial joint contact forces were compared to estimates from a non-invasive joint contact force model (Smith et al., 2008.). The maximum mean axial forces measured during the deep knee bend were 24.2 N/kg at 78.2° flexion (subject A) and 31.1 N/kg at 63.5° flexion (subject B) during the deep knee bend (Figure 1.) During the kneeling activity, the maximum mean axial force measured was 29.8 N/kg at 86.8° flexion (subject B.) While the general shapes of the model-estimated curves were similar to the directly measured curves, the axial joint contact force model underestimated the measured contact forces by 7.0 N/kg on average (Figure 2.) The most likely contributor to this underestimation is the lack of co-contraction in the model. The study protocol was limited in that data could not be simultaneously collected due to electromagnetic interference between the motion tracking system and the inductively powered instrumented tibial component. Because skin-mounted markers were used, kinematics may be affected by skin motion artefacts. Despite these limitations, this study presents valuable information that will advance the development of high flexion total knee replacements. The study provides in vivo measurements and non-invasive estimates of joint contact forces during high flexion activities that can be used for joint simulator protocols and finite element modeling


Orthopaedic Proceedings
Vol. 88-B, Issue SUPP_II | Pages 205 - 205
1 May 2006
Garling E Kaptein B Valstar E Nelissen R
Full Access

Outcome measures must be valid, reliable and responsive to change criteria. The most common clinical outcome measures are Knee Society Scores, SF-36 quality of life scores, HAQ and DAS scores. However, performance based measures of functioning may not be dependent on patient report or observer judgment. Examples of objective pre- and post-operative performance outcome measures are surface Electromyography (EMG) of muscles, kinematics and kinetics (gait analysis). For the evaluation of implant survival after joint arthroplasty, Roentgen Stereophotogrammetric Analysis (RSA) is the golden standard to assess micro-motion of the implants. Surface EMG can be used to asses the stability of joints before and after intervention. Calibrating of raw EMG data is necessary to compare the data between subjects. It was shown that calibration of EMG data by means of isokinetic contractions on a dynamometer during flexion and extension was more reliable and repeatable than using a Maximum Voluntary Contraction in patients after total knee arthroplasty. After total knee arthroplasty RA patients have a lower net knee joint moment and a higher co-contraction than controls, indicating avoidance of net joint load and an active stabilization of the knee joint. Fluoroscopy can be used to assess the kinematics of joints. In the pre-operative situation the use of CT models of the involved bones can be matched to the assessed fluoroscopic images. In the post-operative situation CAD models of the implants can be used for this purpose. In this way accurate 3D kinematics of joints can be assessed. During a step-up task of RA patients, the rotating platform of a mobile bearing knee showed no- or far less longitudinal rotation than the femur. Therefore, some of the theoretical advantages of this specific rotating platform knee prosthesis can be questioned. Fluoroscopy has also been used to assess soft tissue artifacts that occur in gait analysis i.e. displacements of skin-mounted markers relative to the underlying bone. The large soft tissue artefacts observed (displacements up to 17 mm and 12 degrees) question the usefulness of parameters found with external movement registration. In order to assess the micromotion of implants after joint arthroplasty a measurement technique with a much higher accuracy than fluoroscopy is needed. RSA uses tantalum markers as landmarks bony structures and as landmarks on the implant. Recently a new RSA technique has been developed that does not rely on the attachment of artificial markers on the implant but uses CAD models of the implant instead. As an example of RSA as outcome measure, results showed that a calciumphosphate coating improves fixation of tibial components in RA patients, thus preventing mechanical loosening and subsequent long-term revision. In another clinical RSA study, it was found that mobile bearing knees are more predictable and forgiving with respect to micromotion compared to posterior stabilized tibial components in RA patients. The results obtained by the above described performance outcome measures can be valued since the accuracy and precision of the used outcome measures are all published


Bone & Joint Research
Vol. 8, Issue 3 | Pages 126 - 135
1 Mar 2019
Sekiguchi K Nakamura S Kuriyama S Nishitani K Ito H Tanaka Y Watanabe M Matsuda S

Objectives

Unicompartmental knee arthroplasty (UKA) is one surgical option for treating symptomatic medial osteoarthritis. Clinical studies have shown the functional benefits of UKA; however, the optimal alignment of the tibial component is still debated. The purpose of this study was to evaluate the effects of tibial coronal and sagittal plane alignment in UKA on knee kinematics and cruciate ligament tension, using a musculoskeletal computer simulation.

Methods

The tibial component was first aligned perpendicular to the mechanical axis of the tibia, with a 7° posterior slope (basic model). Subsequently, coronal and sagittal plane alignments were changed in a simulation programme. Kinematics and cruciate ligament tensions were simulated during weight-bearing deep knee bend and gait motions. Translation was defined as the distance between the most medial and the most lateral femoral positions throughout the cycle.


The Bone & Joint Journal
Vol. 100-B, Issue 12 | Pages 1600 - 1608
1 Dec 2018
Bouaicha S Ernstbrunner L Jud L Meyer DC Snedeker JG Bachmann E

Aims

In patients with a rotator cuff tear, tear pattern and tendon involvement are known risk factors for the development of pseudoparalysis of the shoulder. It remains unclear, however, why similar tears often have very different functional consequences. The present study hypothesizes that individual shoulder anatomy, specifically the moment arms (MAs) of the rotator cuff (RC) and the deltoid muscle, as well as their relative recruitment during shoulder abduction, plays a central role in pseudoparalysis.

Materials and Methods

Biomechanical and clinical analyses of the pseudoparalytic shoulder were conducted based on the ratio of the RC/deltoid MAs, which were used to define a novel anatomical descriptor called the Shoulder Abduction Moment (SAM) index. The SAM index is the ratio of the radii of two concentric spheres based on the centre of rotation of the joint. One sphere captures the humeral head (numerator) and the other the deltoid origin of the acromion (denominator). A computational rigid body simulation was used to establish the functional link between the SAM index and a potential predisposition for pseudoparalysis. A retrospective radiological validation study based on these measures was also undertaken using two cohorts with and without pseudoparalysis and massive RC tears.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 3 | Pages 364 - 369
1 Mar 2011
Suzuki O Sunagawa T Yokota K Nakashima Y Shinomiya R Nakanishi K Ochi M

The transfer of part of the ulnar nerve to the musculocutaneous nerve, first described by Oberlin, can restore flexion of the elbow following brachial plexus injury. In this study we evaluated the additional benefits and effectiveness of quantitative electrodiagnosis to select a donor fascicle. Eight patients who had undergone transfer of a simple fascicle of the ulnar nerve to the motor branch of the musculocutaneous nerve were evaluated. In two early patients electrodiagnosis had not been used. In the remaining six patients, however, all fascicles of the ulnar nerve were separated and electrodiagnosis was performed after stimulation with a commercially available electromyographic system. In these procedures, recording electrodes were placed in flexor carpi ulnaris and the first dorsal interosseous. A single fascicle in the flexor carpi ulnaris in which a high amplitude had been recorded was selected as a donor and transferred to the musculocutaneous nerve. In the two patients who had not undergone electrodiagnosis, the recovery of biceps proved insufficient for normal use. Conversely, in the six patients in whom quantitative electrodiagnosis was used, elbow flexion recovered to an M4 level.

Quantitative intra-operative electrodiagnosis is an effective method of selecting a favourable donor fascicle during the Oberlin procedure. Moreover, fascicles showing a high-amplitude in reading flexor carpi ulnaris are donor nerves that can restore normal elbow flexion without intrinsic loss.


The Bone & Joint Journal
Vol. 99-B, Issue 6 | Pages 779 - 787
1 Jun 2017
Kutzner I Bender A Dymke J Duda G von Roth P Bergmann G

Aims

Tibiofemoral alignment is important to determine the rate of progression of osteoarthritis and implant survival after total knee arthroplasty (TKA). Normally, surgeons aim for neutral tibiofemoral alignment following TKA, but this has been questioned in recent years. The aim of this study was to evaluate whether varus or valgus alignment indeed leads to increased medial or lateral tibiofemoral forces during static and dynamic weight-bearing activities.

Patients and Methods

Tibiofemoral contact forces and moments were measured in nine patients with instrumented knee implants. Medial force ratios were analysed during nine daily activities, including activities with single-limb support (e.g. walking) and double-limb support (e.g. knee bend). Hip-knee-ankle angles in the frontal plane were analysed using full-leg coronal radiographs.


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 5 | Pages 649 - 654
1 May 2009
Nath RK Liu X

Whereas a general trend in the management of obstetric brachial plexus injuries has been nerve reconstruction in patients without spontaneous recovery of biceps function by three to six months of age, many recent studies suggest this may be unnecessary. In this study, the severity of glenohumeral dysplasia and shoulder function and strength in two groups of matched patients with a C5-6 lesion at a mean age of seven years (2.7 to 13.3) were investigated. One group (23 patients) underwent nerve reconstruction and secondary operations, and the other (52 patients) underwent only secondary operations for similar initial clinical presentations. In the patients with nerve reconstruction shoulder function did not improve and they developed more severe shoulder deformities (posterior subluxation, glenoid version and scapular elevation) and required a mean of 2.4 times as many operations as patients without nerve reconstruction.

This study suggests that less invasive management, addressing the muscle and bone complications, is a more effective approach. Nerve reconstruction should be reserved for those less common cases where the C5 and C6 nerve roots will not recover.


The Bone & Joint Journal
Vol. 98-B, Issue 11 | Pages 1517 - 1520
1 Nov 2016
Quick TJ Singh AK Fox M Sinisi M MacQuillan A

Aims

Improvements in the evaluation of outcome after nerve transfers are required. The assessment of force using the Medical Research Council (MRC) grades (0 to 5) is not suitable for this purpose. A ceiling effect is encountered within MRC grade 4/5 rendering this tool insensitive. Our aim was to show how the strength of flexion of the elbow could be assessed in patients who have undergone a re-innervation procedure using a continuous measurement scale.

Methods

A total of 26 patients, 23 men and three women, with a mean age of 37.3 years (16 to 66), at the time of presentation, attended for review from a cohort of 52 patients who had undergone surgery to restore flexion of the elbow after a brachial plexus injury and were included in this retrospective study. The mean follow-up after nerve transfer was 56 months (28 to 101, standard deviation (sd) 20.79). The strength of flexion of the elbow was measured in a standard outpatient environment with a static dynamometer.


Bone & Joint 360
Vol. 2, Issue 3 | Pages 33 - 35
1 Jun 2013

The June 2013 Oncology Roundup360 looks at: whether allograft composite is superior to megaprosthesis in massive reconstruction; pain from glomus tumours; thromboembolism and orthopaedic malignancy; bone marrow aspirate and cavity lesions; metastasectomy in osteosarcoma; spinal giant cell tumour; post-atomic strike sarcoma; and superficial sarcomas and post-operative infection rates.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 5 | Pages 620 - 626
1 May 2007
Nath RK Paizi M

Residual muscle weakness in obstetric brachial plexus palsy results in soft-tissue contractures which limit the functional range of movement and lead to progressive glenoid dysplasia and joint instability. We describe the results of surgical treatment in 98 patients (mean age 2.5 years, 0.5 to 9.0) for the correction of active abduction of the shoulder. The patients underwent transfer of the latissimus dorsi and teres major muscles, release of contractures of subscapularis pectoralis major and minor, and axillary nerve decompression and neurolysis (the modified Quad procedure). The transferred muscles were sutured to the teres minor muscle, not to a point of bony insertion. The mean pre-operative active abduction was 45° (20° to 90°). At a mean follow-up of 4.8 years (2.0 to 8.7), the mean active abduction was 162° (100° to 180°) while 77 (78.6%) of the patients had active abduction of 160° or more. No decline in abduction was noted among the 29 patients (29.6%) followed up for six years or more. This procedure involving release of the contracted internal rotators of the shoulder combined with decompression and neurolysis of the axillary nerve greatly improves active abduction in young patients with muscle imbalance secondary to obstetric brachial plexus palsy.


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 2 | Pages 213 - 219
1 Feb 2006
Kambhampati SBS Birch R Cobiella C Chen L

We describe the results of surgical treatment in a prospective study of 183 consecutive cases of subluxation (101) and dislocation (82) of the shoulder secondary to obstetric brachial plexus palsy between 1995 and 2000. Neurological recovery was rated ‘good’ or ‘useful’ in all children, whose lesions fell into groups 1, 2 or 3 of the Narakas classification. The mean age at operation was 47 months (3 to 204). The mean follow-up was 40 months (24 to 124).

The mean gain in function was 3.6 levels (9.4 to 13) using the Mallet score and 2 (2.1 to 4.1) on the Gilbert score. The mean active global range of shoulder movement was increased by 73°; the mean range of active lateral rotation by 58° and that of supination of the forearm by 51°. Active medial rotation was decreased by a mean of 10°. There were 20 failures. The functional outcome is related to the severity of the neurological lesion, the duration of the dislocation and onset of deformity.


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 8 | Pages 981 - 987
1 Aug 2006
Ramachandran M Eastwood DM