Advertisement for orthosearch.org.uk
Results 1 - 53 of 53
Results per page:
The Bone & Joint Journal
Vol. 104-B, Issue 9 | Pages 1060 - 1066
1 Sep 2022
Jin X Gallego Luxan B Hanly M Pratt NL Harris I de Steiger R Graves SE Jorm L

Aims. The aim of this study was to estimate the 90-day periprosthetic joint infection (PJI) rates following total knee arthroplasty (TKA) and total hip arthroplasty (THA) for osteoarthritis (OA). Methods. This was a data linkage study using the New South Wales (NSW) Admitted Patient Data Collection (APDC) and the Australian Orthopaedic Association National Joint Replacement Registry (AOANJRR), which collect data from all public and private hospitals in NSW, Australia. Patients who underwent a TKA or THA for OA between 1 January 2002 and 31 December 2017 were included. The main outcome measures were 90-day incidence rates of hospital readmission for: revision arthroplasty for PJI as recorded in the AOANJRR; conservative definition of PJI, defined by T84.5, the PJI diagnosis code in the APDC; and extended definition of PJI, defined by the presence of either T84.5, or combinations of diagnosis and procedure code groups derived from recursive binary partitioning in the APDC. Results. The mean 90-day revision rate for infection was 0.1% (0.1% to 0.2%) for TKA and 0.3% (0.1% to 0.5%) for THA. The mean 90-day PJI rates defined by T84.5 were 1.3% (1.1% to 1.7%) for TKA and 1.1% (0.8% to 1.3%) for THA. The mean 90-day PJI rates using the extended definition were 1.9% (1.5% to 2.2%) and 1.5% (1.3% to 1.7%) following TKA and THA, respectively. Conclusion. When reporting the revision arthroplasty for infection, the AOANJRR substantially underestimates the rate of PJI at 90 days. Using combinations of infection codes and PJI-related surgical procedure codes in linked hospital administrative databases could be an alternative way to monitor PJI rates. Cite this article: Bone Joint J 2022;104-B(9):1060–1066


The Bone & Joint Journal
Vol. 104-B, Issue 7 | Pages 820 - 825
1 Jul 2022
Dhawan R Baré JV Shimmin A

Aims. Adverse spinal motion or balance (spine mobility) and adverse pelvic mobility, in combination, are often referred to as adverse spinopelvic mobility (SPM). A stiff lumbar spine, large posterior standing pelvic tilt, and severe sagittal spinal deformity have been identified as risk factors for increased hip instability. Adverse SPM can create functional malposition of the acetabular components and hence is an instability risk. Adverse pelvic mobility is often, but not always, associated with abnormal spinal motion parameters. Dislocation rates for dual-mobility articulations (DMAs) have been reported to be between 0% and 1.1%. The aim of this study was to determine the early survivorship from the Australian Orthopaedic Association National Joint Replacement Registry (AOANJRR) of patients with adverse SPM who received a DMA. Methods. A multicentre study was performed using data from 227 patients undergoing primary total hip arthroplasty (THA), enrolled consecutively. All the patients who had one or more adverse spine or pelvic mobility parameter had a DMA inserted at the time of their surgery. The mean age was 76 years (22 to 93) and 63% were female (n = 145). At a mean of 14 months (5 to 31) postoperatively, the AOANJRR was analyzed for follow-up information. Reasons for revision and types of revision were identified. Results. The AOANJRR reported two revisions: one due to infection, and the second due to femoral component loosening. No revisions for dislocation were reported. One patient died with the prosthesis in situ. Kaplan-Meier survival rate was 99.1% (95% confidence interval 98.3 to 100) at 14 months (number at risk 104). Conclusion. In our cohort of patients undergoing primary THA with one or more factor associated with adverse SPM, DM bearings conferred stability at two years’ follow-up. Cite this article: Bone Joint J 2022;104-B(7):820–825


The Bone & Joint Journal
Vol. 105-B, Issue 8 | Pages 864 - 871
1 Aug 2023
Tyas B Marsh M de Steiger R Lorimer M Petheram TG Inman DS Reed MR Jameson SS

Aims. Several different designs of hemiarthroplasty are used to treat intracapsular fractures of the proximal femur, with large variations in costs. No clinical benefit of modular over monoblock designs has been reported in the literature. Long-term data are lacking. The aim of this study was to report the ten-year implant survival of commonly used designs of hemiarthroplasty. Methods. Patients recorded by the Australian Orthopaedic Association National Joint Replacement Registry (AOANJRR) between 1 September 1999 and 31 December 2020 who underwent hemiarthroplasty for the treatment of a hip fracture with the following implants were included: a cemented monoblock Exeter Trauma Stem (ETS), cemented Exeter V40 with a bipolar head, a monoblock Thompsons prosthesis (Cobalt/Chromium or Titanium), and an Exeter V40 with a Unitrax head. Overall and age-defined cumulative revision rates were compared over the ten years following surgery. Results. A total of 41,949 hemiarthroplasties were included. Exeter V40 with a Unitrax head was the most commonly used (n = 20,707, 49.4%). The overall rate of revision was small. A total of 28,201 patients (67.2%) were aged > 80 years. There were no significant differences in revision rates across all designs of hemiarthroplasty in patients of this age at any time. The revision rates for all designs were < 3.5%, three years postoperatively. At subsequent times the ETS and Exeter V40 with a bipolar head performed well in all age groups. The unadjusted ten-year mortality rate for the whole cohort was 82.2%. Conclusion. There was no difference in implant survival between all the designs of hemiarthroplasty in the first three years following surgery, supporting the selection of a cost-effective design of hemiarthroplasty for most patients with an intracapsular fracture of the hip, as determined by local availability and costs. Beyond this, the ETS and Exeter bipolar designs performed well in all age groups. Cite this article: Bone Joint J 2023;105-B(8):864–871


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_8 | Pages 9 - 9
10 May 2024
Owen D
Full Access

Background. Increasing evidence suggests a link between the bearing surface used in total hip arthroplasty (THA) and the occurrence of infection. It is postulated that polyethylene has immunomodulatory effects and may influence bacterial function and survival, thereby impacting the development of periprosthetic joint infection (PJI). This study aimed to investigate the association between polyethylene type and revision surgery for PJI in THA using data from the Australian Orthopaedic Association National Joint Replacement Registry (AOANJRR). We hypothesized that the use of XLPE would demonstrate a statistically significant reduction in revision rates due to PJI compared to N-XLPE. Methods. Data from the Australian Orthopaedic Association National Joint Replacement Registry (AOANJRR) spanning September 1, 1999, to December 31, 2021, were used to compare the infection revision rates between THA using N-XLPE and XLPE. We calculated the Cumulative Percentage Revision rate (CPR) and Hazard Ratio (HR) while controlling for factors like age, sex, body mass index (BMI), American Society of Anesthesiologists’ (ASA) grade, and head size. Results. From the total 361,083 primary THAs, 26,827 used N-XLPE and 334,256 used XLPE. Excluding data from the first 6 months post-surgery, 220 revisions occurred in the N-XLPE group and 1,055 in the XLPE group for PJI. The HR for infection revision was significantly higher in N-XLPE compared to XLPE, at 1.64 (95% CI, 1.41–1.90, p<0.001). Conclusions. This analysis provides evidence of an association between N-XLPE and revision for infection in THA. We suspect that polyethylene wear particles contribute to the susceptibility of THA to PJI, resulting in a significantly higher risk of revision for infection in N-XLPE hips compared to those with XLPE. Level of Evidence. Therapeutic Level III


The Bone & Joint Journal
Vol. 104-B, Issue 7 | Pages 894 - 901
1 Jul 2022
Aebischer AS Hau R de Steiger RN Holder C Wall CJ

Aims. The aim of this study was to investigate the rate of revision for distal femoral arthroplasty (DFA) performed as a primary procedure for native knee fractures using data from the Australian Orthopaedic Association National Joint Arthroplasty Registry (AOANJRR). Methods. Data from the AOANJRR were obtained for DFA performed as primary procedures for native knee fractures from 1 September 1999 to 31 December 2020. Pathological fractures and revision for failed internal fixation were excluded. The five prostheses identified were the Global Modular Arthroplasty System, the Modular Arthroplasty System, the Modular Universal Tumour And Revision System, the Orthopaedic Salvage System, and the Segmental System. Patient demographic data (age, sex, and American Society of Anesthesiologists grade) were obtained, where available. Kaplan-Meier estimates of survival were used to determine the rate of revision, and the reasons for revision and mortality data were examined. Results. The AOANJRR identified 153 primary DFAs performed for native knee fractures in 151 patients during the study period, with 63.3% of these (n = 97) performed within the last five years. The median follow-up was 2.1 years (interquartile range 0.8 to 4.4). The patient population was 84.8% female (n = 128), with a mean age of 76.1 years (SD 11.9). The cumulative percent revision rate at three years was 10%. The most common reason for revision was loosening, followed by infection. Patient survival at one year was 87.5%, decreasing to 72.8% at three years postoperatively. Conclusion. The use of DFA to treat native knee fractures is increasing, with 63.3% of cases performed within the last five years. While long-term data are not available, the results of this study suggest that DFA may be a reasonable option for elderly patients with native knee fractures where fixation is not feasible, or for whom prolonged non-weightbearing may be detrimental. Cite this article: Bone Joint J 2022;104-B(7):894–901


The Bone & Joint Journal
Vol. 101-B, Issue 1 | Pages 92 - 95
1 Jan 2019
Harris IA Cuthbert A de Steiger R Lewis P Graves SE

Aims. Displaced femoral neck fractures (FNF) may be treated with partial (hemiarthroplasty, HA) or total hip arthroplasty (THA), with recent recommendations advising that THA be used in community-ambulant patients. This study aims to determine the association between the proportion of FNF treated with THA and year of surgery, day of the week, surgeon practice, and private versus public hospitals, adjusting for known confounders. Patients and Methods. Data from 67 620 patients in the Australian Orthopaedic Association National Joint Replacement Registry (AOANJRR) from 1999 to 2016 inclusive were used to generate unadjusted and adjusted analyses of the associations between patient, time, surgeon and institution factors, and the proportion of FNF treated with THA. Results. Overall, THA was used in 23.7% of patients. THA was more frequently used over time, in younger patients, in healthier patients, in cases performed on weekdays (adjusted odds ratio (OR) 1.27; 95% confidence interval (CI) 1.14 to 1.41), in private hospitals (adjusted OR 4.34; 95% CI 3.94 to 4.79) and by surgeons whose hip arthroplasty practice has a relatively higher proportion of elective patients (adjusted OR 1.65; 95% CI 1.49 to 1.83). Conclusion. Practice variation exists in the proportion of FNF patients treated with THA due to variables other than patient factors. This may reflect variation in resources available and surgeon preference, and uncertainty regarding the relative indication


Bone & Joint Open
Vol. 3, Issue 5 | Pages 367 - 374
5 May 2022
Sinagra ZP Davis JS Lorimer M de Steiger RN Graves SE Yates P Manning L

Aims. National joint registries under-report revisions for periprosthetic joint infection (PJI). We aimed to validate PJI reporting to the Australian Orthopaedic Association National Joint Arthroplasty Registry (AOANJRR) and the factors associated with its accuracy. We then applied these data to refine estimates of the total national burden of PJI. Methods. A total of 561 Australian cases of confirmed PJI were captured by a large, prospective observational study, and matched to data available for the same patients through the AOANJRR. Results. In all, 501 (89.3%) cases of PJI recruited to the prospective observational study were successfully matched with the AOANJRR database. Of these, 376 (75.0%) were captured by the registry, while 125 (25.0%) did not have a revision or reoperation for PJI recorded. In a multivariate logistic regression analysis, early (within 30 days of implantation) PJIs were less likely to be reported (adjusted odds ratio (OR) 0.56; 95% confidence interval (CI) 0.34 to 0.93; p = 0.020), while two-stage revision procedures were more likely to be reported as a PJI to the registry (OR 5.3 (95% CI 2.37 to 14.0); p ≤ 0.001) than debridement and implant retention or other surgical procedures. Based on this data, the true estimate of the incidence of PJI in Australia is up to 3,900 cases per year. Conclusion. In Australia, infection was not recorded as the indication for revision or reoperation in one-quarter of those with confirmed PJI. This is better than in other registries, but suggests that registry-captured estimates of the total national burden of PJI are underestimated by at least one-third. Inconsistent PJI reporting is multifactorial but could be improved by developing a nested PJI registry embedded within the national arthroplasty registry. Cite this article: Bone Jt Open 2022;3(5):367–373


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_2 | Pages 56 - 56
10 Feb 2023
Vaotuua D O'Connor P Belford M Lewis P Hatton A McAuliffe M
Full Access

Deep infection is a devastating complication of total knee arthroplasty (TKA). This study aimed to determine if there was a relationship between surgeon volume and the incidence of revision for infection after primary TKA. Data from the Australian Orthopaedic Association National Joint Replacement Registry (AOANJRR) from 1 September 1999 to 31 December 2020 for primary TKA for osteoarthritis that were revised for infection. Surgeon volume was defined by the number of primary TKA procedures performed by the surgeon in the year the primary TKA was performed and grouped as <25, 25-49, 50-74, 75-99, >100 primary TKA procedures per year. Kaplan Meir estimates for cumulative percent revision (CPR) and Cox Proportional Hazard Ratios were performed to compare rates of revision for infection by surgeon volume, with sub-analyses for patella and polyethylene use, age <65 years and male gender. 5295 of 602,919 primary TKA for osteoarthritis were revised for infection. High volume surgeons (>100 TKA/year) had a significantly lower rate of revision for infection with a CPR at 1 and 17 years of 0.4% (95% CI 0.3, 0.4) and 1.5% (95% CI 1.2, 2.0), respectively, compared with 0.6% (95% CI 0.5, 0.7) and 2.1% (95% CI 1.8, 2.3), respectively, for low volume surgeons (<25 TKR/year). Differences between the high-volume group and the remaining groups remained when sub-analysis for age, gender, ASA, BMI, patella resurfacing and the use of cross-linked polyethylene (XLPE). High volume surgeons have lower rates of revision for infection in primary TKA


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_13 | Pages 57 - 57
7 Aug 2023
Gill J Brimm D McMeniman P McMeniman T Myers P
Full Access

Abstract. Introduction. Patient selection is key to the success of medial unicondylar knee arthroplasty (UKA). Progression of arthritis is the most common indication for revision. Various methods of assessing the lateral compartment have been used including stress radiography, radioisotope bone scanning, MRI, and visualisation at the time of surgery. Arthroscopy is another means of assessing the integrity of the lateral compartment. Methods. We used per-operative arthroscopy as a means to confirm suitability for UKA in a consecutive series of 279 Oxford medial UKA. This study reports the long-term results of a previously published cohort of knees. Our series of UKA with per-operative arthroscopy (Group 1) was compared to all Oxford UKA (Group 2) and all UKA in the Australian Orthopaedic Association National Joint Replacement Registry (AOANJRR) (Group 3). Results. The 14-year cumulative percentage revision (CPR) was 18.5% (95% CI 12.7, 26.4) for group 1, 19.7% (95% CI 18.8, 20.6) for group 2, and 19.2% (95% CI 18.5, 19.8) for group 3. There was no statistically significant difference in the (CPR) for the entire period when group 1 was compared to groups 2 or 3. Progression of arthritis was the indication for revision in similar proportions for the three groups (Group 1: 32.3%, Group 2: 35.7% and Group 3: 33.5%). Following per-operative arthroscopy 21.6% (77/356) of knees underwent a change of surgical plan from UKA to TKA. Conclusion. Per-operative arthroscopy may improve medium-term medial unicompartmental knee survivorship but does not improve long-term survivorship nor reduce revision due to progression of arthritis


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_2 | Pages 24 - 24
10 Feb 2023
Truong A Wall C Stoney J Graves S Lorimer M de Steiger R
Full Access

Obesity is a known risk factor for hip osteoarthritis. The aim of this study was to compare the incidence of obesity in Australians undergoing hip replacements (HR) for osteoarthritis to the general population. A cohort study was conducted comparing data from the Australian Bureau of Statistics and the Australian Orthopaedic Association National Joint Replacement Registry (AOANJRR) from 2017-18. Body mass index (BMI) data for patients undergoing primary total hip replacement and resurfacing for osteoarthritis were obtained from the AOANJRR. The distribution of HR patients by BMI category was compared to the general population, in age and sex sub-groups. During the study period, 32,495 primary HR were performed for osteoarthritis in Australia. Compared to the general population, there was a higher incidence of Class I, II, and III obesity in patients undergoing HR in both sexes aged 35 to 74 years old. Class III obese females and males undergoing HR were on average 6 to 7 years younger than their normal weight counterparts. Class III obese females and males aged 55-64 years old were 2.9 and 1.7 times more likely to undergo HR, respectively (p<0.001). There is a strong association between increased BMI and relative risk of undergoing HR. Similar findings have been noted in the United States of America, Canada, United Kingdom, Sweden and Spain. A New Zealand Registry study and recent meta-analysis have also found a concerning trend of Class III obese patients undergoing HR at a younger age. Obese Australians are at increased risk of undergoing HR at a younger age. A national approach to address the prevalence of obesity is needed


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_2 | Pages 107 - 107
10 Feb 2023
Xu J Sivakumar B Nandapalan H Moopanar T Harries D Page R Symes M
Full Access

Proximal humerus fractures (PHF) are common, accounting for approximately 5% of all fractures. Approximately 30% require surgical intervention which can range from open reduction with internal fixation (ORIF) to shoulder arthroplasty (including hemiarthroplasty, total shoulder arthroplasty, (TSA) or reverse total shoulder arthroplasty (RTSA)). The aim of this study was to assess trends in operative interventions for PHF in an Australian population. Data was retrospectively collected for patients diagnosed with a PHF and requiring surgical intervention between January 2001 and December 2020. Data for patients undergoing ORIF were extracted from the Medicare database, while data for patients receiving arthroplasty for PHF were obtained from the Australian Orthopaedic Association National Joint Replacement Registry (AOANJRR). Across the study period, ORIF was the most common surgical procedure for management of PHFs. However, since 2019, RTSA has surpassed ORIF as the most common surgical procedure to treat PHFs, accounting for 51% of operations. While the number of RTSA procedures for PHF has increased, ORIF and shoulder hemiarthroplasty has significantly reduced since 2007 (p < 0.001). TSA has remained uncommon across the follow-up period, accounting for less than 1% of all operations. Patients younger than 65 years were more likely to receive ORIF, while those aged 65 years or greater were more likely to receive hemiarthroplasty or RTSA. While the number of ORIF procedures has increased during the period of interest, it has diminished as a proportion of overall procedure volume. RTSA is becoming increasingly popular, with decreasing utilization of hemiarthroplasty, and TSA for fracture remaining uncommon. These trends provide information that can be used to guide resource allocation and health provision in the future. A comparison to similar data from other nations would be useful


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_3 | Pages 69 - 69
23 Feb 2023
Morgan S Wall C de Steiger R Graves S Page R Lorimer M
Full Access

The aim of this study was to examine the incidence of obesity in patients undergoing primary total shoulder replacement (TSR) (stemmed and reverse) for osteoarthritis (OA) in Australia compared to the incidence of obesity in the general population. A 2017–18 cohort of 2,621 patients from the Australian Orthopaedic Association National Joint Replacement Registry (AOANJRR) who underwent TSR, were compared with matched controls from the Australian Bureau of Statistics (ABS) National Health Survey from the same period. The two groups were analysed according to BMI category, sex and age. According to the 2017–18 National Health Survey, 35.6% of Australian adults are overweight and 31.3% are obese. Of the primary TSR cases performed, 34.2% were overweight and 28.6% were obese. The relative risk of requiring TSR for OA increased with increasing BMI category. Class-3 obese females, aged 55–64, were 8.9 times more likely to require TSR compared to normal weight counterparts. Males in the same age and BMI category were 2.5 times more likely. Class-3 obese patients underwent TSR 4 years (female) and 7 years (male) sooner than their normal weight counterparts. Our findings suggest that the obese population is at risk for early and more frequent TSR for OA. Previous studies demonstrate that obese patients undergoing TSR also exhibit increased risks of longer operative times, higher superficial infection rates, higher periprosthetic fracture rates, significantly reduced post-operative forward flexion range and greater revision rates. Obesity significantly increases the risk of requiring TSR. To our knowledge this is the first study to publish data pertaining to age and BMI stratification of TSR Societal efforts are vital to diminish the prevalence and burden of obesity related TSR. There may well be reversible pathophysiology in the obese population to address prior to surgery (adipokines, leptin, NMDA receptor upregulation). Surgery occurs due to recalcitrant or increased pain despite non-op Mx


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_2 | Pages 28 - 28
10 Feb 2023
Faveere A Milne L Holder C Graves S
Full Access

Increasing femoral offset in total hip replacement (THR) has several benefits including improved hip abductor strength and enhanced range of motion. Biomechanical studies have suggested that this may negatively impact on stem stability. However, it is unclear whether this has a clinical impact. Using data from the Australian Orthopaedic Association National Joint Replacement Registry (AOANJRR), the aim of this study was to determine the impact of stem offset and stem size for the three most common cementless THR prostheses revised for aseptic loosening. The study period was September 1999 to December 2020. The study population included all primary procedures for osteoarthritis with a cementless THR using the Corail, Quadra-H and Polarstem. Procedures were divided into small and large stem sizes and by standard and high stem offset for each stem system. Hazard ratios (HR) from Cox proportional hazards models, adjusting for age and gender, were performed to compare revision for aseptic loosening for offset and stem size for each of the three femoral stems. There were 55,194 Corail stems, 13,642 Quadra-H stem, and 13,736 Polarstem prostheses included in this study. For the Corail stem, offset had an impact only when small stems were used (sizes 8-11). Revision for aseptic loosening was increased for the high offset stem (HR=1.90;95% CI 1.53–2.37;p<0.001). There was also a higher revision risk for aseptic loosening for high offset small size Quadra-H stems (sizes 0-3). Similar to the Corail stem, offset did not impact on the revision risk for larger stems (Corail sizes 12-20, Quadra-H sizes 4-7). The Polarstem did not show any difference in aseptic loosening revision risk when high and standard offset stems were compared, and this was irrespective of stem size. High offset may be associated with increased revision for aseptic loosening, but this is both stem size and prosthesis specific


The Bone & Joint Journal
Vol. 102-B, Issue 3 | Pages 319 - 328
1 Mar 2020
St Mart J de Steiger RN Cuthbert A Donnelly W

Aim. There has been a significant reduction in unicompartmental knee arthroplasty (UKA) procedures recorded in Australia. This follows several national joint registry studies documenting high UKA revision rates when compared to total knee arthroplasty (TKA). With the recent introduction of robotically assisted UKA procedures, it is hoped that outcomes improve. This study examines the cumulative revision rate of UKA procedures implanted with a newly introduced robotic system and compares the results to one of the best performing non-robotically assisted UKA prostheses, as well as all other non-robotically assisted UKA procedures. Methods. Data from the Australian Orthopaedic Association National Joint Arthroplasty Registry (AOANJRR) for all UKA procedures performed for osteoarthritis (OA) between 2015 and 2018 were analyzed. Procedures using the Restoris MCK UKA prosthesis implanted using the Mako Robotic-Arm Assisted System were compared to non-robotically assisted Zimmer Unicompartmental High Flex Knee System (ZUK) UKA, a commonly used UKA with previously reported good outcomes and to all other non-robotically assisted UKA procedures using Cox proportional hazard ratios (HRs) and Kaplan-Meier estimates of survivorship. Results. There was no difference in the rate of revision when the Mako-assisted Restoris UKA was compared to the ZUK UKA (zero to nine months: HR 1.14 (95% CI 0.71 to 1.83; p = 0.596) vs nine months and over: HR 0.66 (95% CI 0.42 to 1.02; p = 0.058)). The Mako-assisted Restoris had a significantly lower overall revision rate compared to the other types of non-robotically assisted procedures (HR 0.58 (95% confidence interval (CI) 0.42 to 0.79); p < 0.001) at three years. Revision for aseptic loosening was lower for the Mako-assisted Restoris compared to all other non-robotically assisted UKA (entire period: HR 0.34 (95% CI 0.17 to 0.65); p = 0.001), but not the ZUK prosthesis. However, revision for infection was significantly higher for the Mako-assisted Restoris compared to the two comparator groups (ZUK: entire period: HR 2.91 (95% CI 1.22 to 6.98; p = 0.016); other non-robotically assisted UKA: zero to three months: HR 5.57 (95% CI 2.17 to 14.31; p < 0.001)). Conclusion. This study reports comparable short-term survivorship for the Mako robotically assisted UKA compared to the ZUK UKA and improved survivorship compared to all other non-robotic UKA. These results justify the continued use and investigation of this procedure. However, the higher rate of early revision for infection for robotically assisted UKA requires further investigation. Cite this article: Bone Joint J 2020;102-B(3):319–328


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_2 | Pages 64 - 64
10 Feb 2023
Lourens E Kurmis A Harries D de Steiger RN
Full Access

Total hip arthroplasty (THA) is an effective treatment for symptomatic hip osteoarthritis (OA). While computer-navigation technologies in total knee arthroplasty show survivorship advantages and are widely used, comparable applications within THA show far lower utilisation. Using national registry data, this study compared patient reported outcome measures (PROMs) in patients who underwent THA with and without computer navigation. Data from Australian Orthopaedic Association National Joint Replacement Registry (AOANJRR) PROMs program included all primary THA procedures performed for OA up to 31 December 2020. Procedures using the Intellijoint HIP® navigation system were identified and compared to procedures using other computer navigation systems or conventional instrumentation only. Changes in PROM scores between pre-operative and 6-month post-operative time points were analysed using multiple regression model, adjusting for pre-operative score, patient age, gender, ASA score, BMI, surgical approach, and hospital type. There were 65 primary THA procedures that used the Intellijoint HIP® system, 90 procedures used other types of computer navigation, and the remaining 5,284 primary THA procedures used conventional instrumentation. The estimated mean changes in the EuroQol visual analogue scale (EQ VAS) score and Oxford Hip score did not differ significantly when Intellijoint® was compared to conventional instruments (estimated differences of 2.4, 95% CI [-1.7, 6.5], p = 0.245, and −0.5, 95% CI [-2.5, 1.4], p = 0.592, respectively). The proportion of patients who were satisfied with their procedure was also similar when Intellijoint® was compared to conventional instruments (rate ratio 1.06, 95% CI [0.97, 1.16], p = 0.227). The preliminary data demonstrate no significant difference in PROMs when comparing the Intellijoint HIP® THA navigation system with both other navigation systems and conventional instrumentation for primary THAs performed for OA. Level of evidence: III (National registry analysis)


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_1 | Pages 83 - 83
1 Feb 2020
Shimmin A Pierrepont J Bare J McMahon S
Full Access

Introduction & aims. Apparently well-orientated total hip replacements (THR) can still fail due to functional component malalignment. Previously defined “safe zones” are not appropriate for all patients as they do not consider an individual's spinopelvic mobility. The Optimized Positioning System, OPS. TM. (Corin, UK), comprises preoperative planning based on a patient-specific dynamic analysis, and patient-specific instrumentation for delivery of the target component alignment. The aim of this study was to determine the early revision rate from the Australian Orthopaedic Association National Joint Replacement Registry (AOANJRR) for THRs implanted using OPS. TM. . Method. Between January 4. th. 2016 and December 20. st. 2017, a consecutive series of 841 OPS. TM. cementless total hip replacements were implanted using a Trinity acetabular cup (Corin, UK) with either a TriFit TS stem (98%) or a non-collared MetaFix stem (2%). 502 (59%) procedures were performed through a posterior approach, and 355 (41%) using the direct superior approach. Mean age was 64 (range; 27 to 92) and 51% were female. At a mean follow-up of 15 months (range; 3 to 27), the complete list of 857 patients was sent to the AOANJRR for analysis. Results. There were 5 revisions: . a periprosthetic femoral fracture at 1-month post-op in a 70F. a ceramic head fracture at 12-months post-op in a 59M. a femoral stem loosening at 7-months post-op in a 58M. a femoral stem loosening at 16-months post-op in a 64M. an anterior dislocation in a 53M, that was revised 9 days after the primary procedure. CT analysis, prior to revision surgery, revealed acetabular cup orientation of 46°/31° (inclination/anteversion) and femoral stem anteversion of 38°. Conclusions. These preliminary findings suggest the OPS. TM. dynamic planning and delivery system provides good early results, with a low rate of revision for dislocation. Limitations of the study will be discussed


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_9 | Pages 18 - 18
1 May 2018
Mammoliti L Van Bavel D De Steiger R Rainbird S
Full Access

Introduction/Aims. The Exeter Stem can be used with metal femoral head that are made of either cobalt chrome, or stainless steel. The aim of this study was to compare the rates of revision of these two metal femoral head types when used with this femoral component. Method. Australian Orthopaedic Association National Joint Replacement Registry (AOANJRR) Data from September 1999 until December 2015 for all primary THRs using an Exeter or an Exeter v40 stem with the diagnosis of osteoarthritis were analysed. Only bearing couples that used a metal head with polyethylene were included. The cumulative percent revision (CPR) calculated using Kaplan-Meier estimates were compared for the two metal head types. CPR were further analysed by age, polyethylene type and head size. Reasons for revision and types of revision were assessed. Results. There were 51666 THR that used Exeter or Exeter v40 stems of which 12554 had femoral heads made of cobalt chrome and 39112 had heads made of stainless steel. There was no difference in the rate of revision overall when head types were compared. There was also no difference in CPR between the two head types with age. Hips that used cobalt chrome heads had a higher CPR than stainless steel heads when these were used against non-crosslinked polyethylene. When heads with a diameter of 32mm or greater were compared, those made of cobalt chrome had a higher rate of revision than stainless steel HR 1.38 (1.15, 1.66) P<0.001). Conclusion. There was no difference comparing cobalt chrome or stainless-steel heads, except where non-crosslinked polyethylene was used, or where the heads size was 32mm or greater. In these comparisons, heads made from cobalt chrome had a higher rate of revision


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXIX | Pages 236 - 236
1 Sep 2012
Roche J Joss B DeSteiger R Miller L Nivbrant B Wood D
Full Access

There is ongoing debate on the benefits of fixed versus mobile bearing Unicompartmental Knee Replacement (UKR). We report the results from a randomised controlled trial comparing fixed and mobile bearing of the same UKR prosthesis. Forty patients were randomized to receive identical femoral components and either a fixed or mobile bearing tibial component. At 6.5 years follow-up 37% of the mobile bearing design had been revised and 14% for the fixed bearing design. The main reasons for revision were pain and loosening. These results were compared with data from The Australian Orthopaedic Association National Joint Replacement Registry (AOANJRR) that show a cumulative percent revision of 24.2% for the mobile bearing Preservation UKR at 6.5 years. All locally explanted mobile bearings were examined microscopically, and 83% demonstrated significant backside wear. Constraint on the undersurface of the bearing coupled with a congruent upper surface may have contributed to the excessive revision rate. This is the first randomised controlled trial examining mobile and fixed variations of the same UKR prosthesis and shows this design of UKR with the mobile bearing has an unacceptably high revision rate and patients with this knee design should be closely monitored


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_22 | Pages 3 - 3
1 Dec 2016
Dunbar M
Full Access

Over the past 15 years metal on metal hip resurfacing (MOMHR) has seen a spectacular resurgence in utilization followed by near abandonment of the procedure. A select group of surgeons still offer the procedure to a select group of patients suggesting that there are benefits of MOMHR over total hip arthroplasty (THA). This is problematic for the following reasons:. 1). MOMHR does not lead to increased survivorship. The Australian Orthopaedic Association National Joint Replacement Registry (AOANJRR) and the England and Wales National Joint Registry, from countries with high rates of utilization of MOMHR, both report significantly worse survivorship with MOMHR compared to all types of conventional THA. Risk factors for revision of resurfacing were older patients, females, smaller femoral head size, patients with developmental dysplasia, and certain implant designs. 2). MOMHR is associated with the generation of metal ions that can have devastating effects in some patients. Cobalt and chromium ions generated from MOMHR can result in adverse local tissues reactions around the hip, sometimes with catastrophic consequences, as well as neurological deficits, skin rashes, and cardiomyopathy. It is unclear as to which patients are at risk for the generation of high ion levels and less clear with respect to the host response to these ions. The discriminative and predictive values of ion testing are still being determined. MOMHR subsequently require careful follow-up with limited tools to assess risk and pending problems. 3). MOMHR is not less invasive. In order to deliver the femoral head for safe preparation and to access the acetabulum with the femoral head and neck in situ, significant dissection and retraction are required. The exposure issue is compounded as the procedure is most often performed in younger, larger males. Difficulty with exposure has been associated with an insult to the femoral head's blood supply that may lead to fracture and/or neck narrowing. 4). Preservation of the femoral canal with MOMHR does not improve outcomes of revision. The perceived advantage of preserved femoral head and neck implies that a conversion of a MOMHR to total hip should convey survivorship similar to primary THA. However, this is not the case as confirmed by data from the AOANJRR demonstrating worse survivorship of revised resurfacings when compared to a primary total hip arthroplasty. 5). MOMHR does not result in superior functional outcomes. Advocates for MOMHR often claim that the large femoral head and intact femoral neck in resurfacing results in a better functional outcome and therefore, a better quality of life and satisfaction when compared to a conventional THA. This, however, was not the case when gait speed, postural balance evaluations and functional tests were used in a randomised study of 48 patients, which failed to show an advantage of MOMHR over THA. In conclusion, it is relatively straightforward to oppose and argue against the use of hip resurfacings as they have worse outcomes in all National Joint Registries, produce metal ions with significant clinical consequences, are more invasive, are difficult to revise with subsequent inferior outcomes when compared to a conventional primary THA, and do not provide better function. These adverse features come with a premium price when compared to a conventional THA


Bone & Joint 360
Vol. 12, Issue 6 | Pages 49 - 51
1 Dec 2023
Burden EG Whitehouse MR Evans JT


Bone & Joint 360
Vol. 11, Issue 4 | Pages 44 - 46
1 Aug 2022
Evans JT Walton TJ Whitehouse MR


The Bone & Joint Journal
Vol. 106-B, Issue 3 Supple A | Pages 121 - 129
1 Mar 2024
Orce Rodríguez A Smith PN Johnson P O'Sullivan M Holder C Shimmin A

Aims

In recent years, the use of a collared cementless femoral prosthesis has risen in popularity. The design intention of collared components is to transfer some load to the resected femoral calcar and prevent implant subsidence within the cancellous bone of the metaphysis. Conversely, the load transfer for a cemented femoral prosthesis depends on the cement-component and cement-bone interface interaction. The aim of our study was to compare the three most commonly used collared cementless components and the three most commonly used tapered polished cemented components in patients aged ≥ 75 years who have undergone a primary total hip arthroplasty (THA) for osteoarthritis (OA).

Methods

Data from the Australian Orthopaedic Association National Joint Replacement Registry from 1 September 1999 to 31 December 2022 were analyzed. Collared cementless femoral components and cemented components were identified, and the three most commonly used components in each group were analyzed. We identified a total of 11,278 collared cementless components and 47,835 cemented components. Hazard ratios (HRs) from Cox proportional hazards models, adjusting for age and sex, were obtained to compare the revision rates between the groups.


The Bone & Joint Journal
Vol. 104-B, Issue 5 | Pages 613 - 619
2 May 2022
Ackerman IN Busija L Lorimer M de Steiger R Graves SE

Aims

This study aimed to describe the use of revision knee arthroplasty in Australia and examine changes in lifetime risk over a decade.

Methods

De-identified individual-level data on all revision knee arthroplasties performed in Australia from 2007 to 2017 were obtained from the Australian Orthopaedic Association National Joint Replacement Registry. Population data and life tables were obtained from the Australian Bureau of Statistics. The lifetime risk of revision surgery was calculated for each year using a standardized formula. Separate calculations were undertaken for males and females.


The Bone & Joint Journal
Vol. 103-B, Issue 1 | Pages 7 - 15
1 Jan 2021
Farhan-Alanie MM Burnand HG Whitehouse MR

Aims

This study aimed to compare the effect of antibiotic-loaded bone cement (ALBC) versus plain bone cement (PBC) on revision rates for periprosthetic joint infection (PJI) and all-cause revisions following primary elective total hip arthroplasty (THA) and total knee arthroplasty (TKA).

Methods

MEDLINE, Embase, Web of Science, and Cochrane databases were systematically searched for studies comparing ALBC versus PBC, reporting on revision rates for PJI or all-cause revision following primary elective THA or TKA. A random-effects meta-analysis was performed. The study was registered in the International Prospective Register of Systematic Reviews (PROSPERO ID CRD42018107691).


The Bone & Joint Journal
Vol. 103-B, Issue 12 | Pages 1791 - 1801
1 Dec 2021
Bhalekar RM Nargol ME Shyam N Nargol AVF Wells SR Collier R Pabbruwe M Joyce TJ Langton DJ

Aims

The aim of this study was to investigate whether wear and backside deformation of polyethylene (PE) tibial inserts may influence the cement cover of tibial trays of explanted total knee arthroplasties (TKAs).

Methods

At our retrieval centre, we measured changes in the wear and deformation of PE inserts using coordinate measuring machines and light microscopy. The amount of cement cover on the backside of tibial trays was quantified as a percentage of the total surface. The study involved data from the explanted fixed-bearing components of four widely used contemporary designs of TKA (Attune, NexGen, Press Fit Condylar (PFC), and Triathlon), revised for any indication, and we compared them with components that used previous generations of PE. Regression modelling was used to identify variables related to the amount of cement cover on the retrieved trays.


Bone & Joint 360
Vol. 13, Issue 4 | Pages 43 - 45
2 Aug 2024
Evans JT Evans JP Whitehouse MR


Bone & Joint 360
Vol. 10, Issue 2 | Pages 57 - 59
1 Apr 2021
Evans JT Whitehouse MR Evans JP


Bone & Joint 360
Vol. 12, Issue 4 | Pages 44 - 46
1 Aug 2023
Burden EG Whitehouse MR Evans JT


The Bone & Joint Journal
Vol. 106-B, Issue 3 | Pages 220 - 223
1 Mar 2024
Kayani B Luo TD Haddad FS


The Bone & Joint Journal
Vol. 105-B, Issue 9 | Pages 946 - 952
1 Sep 2023
Dhawan R Young DA Van Eemeren A Shimmin A

Aims

The Birmingham Hip Resurfacing (BHR) arthroplasty has been used as a surgical treatment of coxarthrosis since 1997. We present 20-year results of 234 consecutive BHRs performed in our unit.

Methods

Between 1999 and 2001, there were 217 patients: 142 males (65.4%), mean age 52 years (18 to 68) who had 234 implants (17 bilateral). They had patient-reported outcome measures collected, imaging (radiograph and ultrasound), and serum metal ion assessment. Survivorship analysis was performed using Kaplan-Meier estimates. Revision for any cause was considered as an endpoint for the analysis.


Bone & Joint 360
Vol. 13, Issue 1 | Pages 13 - 16
1 Feb 2024

The February 2024 Hip & Pelvis Roundup360 looks at: Trial of vancomycin and cefazolin as surgical prophylaxis in arthroplasty; Is preoperative posterior femoral neck tilt a risk factor for fixation failure? Cemented versus uncemented hemiarthroplasty for displaced intracapsular fractures of the hip; Periprosthetic fractures in larger hydroxyapatite-coated stems: are collared stems a better alternative for total hip arthroplasty?; Postoperative periprosthetic fracture following hip arthroplasty with a polished taper slip versus composite beam stem; Is oral tranexamic acid as good as intravenous?; Stem design and the risk of early periprosthetic femur fractures following THA in elderly patients; Does powered femoral broaching compromise patient safety in total hip arthroplasty?


Bone & Joint 360
Vol. 12, Issue 6 | Pages 31 - 34
1 Dec 2023

The December 2023 Shoulder & Elbow Roundup360 looks at: Clavicle fractures: is the evidence changing practice?; Humeral shaft fractures, and another meta-analysis…let’s wait for the trials now!; Hemiarthroplasty or total elbow arthroplasty for distal humeral fractures…what does the registry say?; What to do with a first-time shoulder dislocation?; Deprivation indices and minimal clinically important difference for patient-reported outcomes after arthroscopic rotator cuff repair; Prospective randomized clinical trial of arthroscopic repair versus debridement for partial subscapularis tears; Long-term follow-up following closed reduction and early movement for simple dislocation of the elbow; Sternoclavicular joint reconstruction for traumatic acute and chronic anterior and posterior instability.


Bone & Joint Open
Vol. 5, Issue 3 | Pages 202 - 209
11 Mar 2024
Lewin AM Cashman K Harries D Ackerman IN Naylor JM Harris IA

Aims

The aim of this study was to describe and compare joint-specific and generic health-related quality of life outcomes of the first versus second knee in patients undergoing staged bilateral total knee arthroplasty (BTKA) for osteoarthritis.

Methods

This retrospective cohort study used Australian national arthroplasty registry data from January 2013 to January 2021 to identify participants who underwent elective staged BTKA with six to 24 months between procedures. The primary outcome was Oxford Knee Score (OKS) at six months postoperatively for the first TKA compared to the second TKA, adjusted for age and sex. Secondary outcomes compared six-month EuroQol five-dimension five-level (EQ-5D-5L) domain scores, EQ-5D index scores, and the EQ visual analogue scale (EQ-VAS) between knees at six months postoperatively.


Bone & Joint Open
Vol. 4, Issue 11 | Pages 839 - 845
6 Nov 2023
Callary SA Sharma DK D’Apollonio TM Campbell DG

Aims

Radiostereometric analysis (RSA) is the most accurate radiological method to measure in vivo wear of highly cross-linked polyethylene (XLPE) acetabular components. We have previously reported very low wear rates for a sequentially irradiated and annealed X3 XLPE liner (Stryker Orthopaedics, USA) when used in conjunction with a 32 mm femoral heads at ten-year follow-up. Only two studies have reported the long-term wear rate of X3 liners used in conjunction with larger heads using plain radiographs which have poor sensitivity. The aim of this study was to measure the ten-year wear of thin X3 XLPE liners against larger 36 or 40 mm articulations with RSA.

Methods

We prospectively reviewed 19 patients who underwent primary cementless THA with the XLPE acetabular liner (X3) and a 36 or 40 mm femoral head with a resultant liner thickness of at least 5.8 mm. RSA radiographs at one week, six months, and one, two, five, and ten years postoperatively and femoral head penetration within the acetabular component were measured with UmRSA software. Of the initial 19 patients, 12 were available at the ten-year time point.


Bone & Joint Open
Vol. 3, Issue 8 | Pages 656 - 665
23 Aug 2022
Tran T McEwen P Peng Y Trivett A Steele R Donnelly W Clark G

Aims

The mid-term results of kinematic alignment (KA) for total knee arthroplasty (TKA) using image derived instrumentation (IDI) have not been reported in detail, and questions remain regarding ligamentous stability and revisions. This paper aims to address the following: 1) what is the distribution of alignment of KA TKAs using IDI; 2) is a TKA alignment category associated with increased risk of failure or poor patient outcomes; 3) does extending limb alignment lead to changes in soft-tissue laxity; and 4) what is the five-year survivorship and outcomes of KA TKA using IDI?

Methods

A prospective, multicentre, trial enrolled 100 patients undergoing KA TKA using IDI, with follow-up to five years. Alignment measures were conducted pre- and postoperatively to assess constitutional alignment and final implant position. Patient-reported outcome measures (PROMs) of pain and function were also included. The Australian Orthopaedic Association National Joint Arthroplasty Registry was used to assess survivorship.


The Bone & Joint Journal
Vol. 106-B, Issue 5 | Pages 482 - 491
1 May 2024
Davies A Sabharwal S Liddle AD Zamora Talaya MB Rangan A Reilly P

Aims

Metal and ceramic humeral head bearing surfaces are available choices in anatomical shoulder arthroplasties. Wear studies have shown superior performance of ceramic heads, however comparison of clinical outcomes according to bearing surface in total shoulder arthroplasty (TSA) and hemiarthroplasty (HA) is limited. This study aimed to compare the rates of revision and reoperation following metal and ceramic humeral head TSA and HA using data from the National Joint Registry (NJR), which collects data from England, Wales, Northern Ireland, Isle of Man and the States of Guernsey.

Methods

NJR shoulder arthroplasty records were linked to Hospital Episode Statistics and the National Mortality Register. TSA and HA performed for osteoarthritis (OA) in patients with an intact rotator cuff were included. Metal and ceramic humeral head prostheses were matched within separate TSA and HA groups using propensity scores based on 12 and 11 characteristics, respectively. The primary outcome was time to first revision and the secondary outcome was non-revision reoperation.


Bone & Joint 360
Vol. 10, Issue 6 | Pages 48 - 50
1 Dec 2021
Evans JT French JMR Whitehouse MR


Bone & Joint 360
Vol. 10, Issue 4 | Pages 49 - 51
1 Aug 2021
Evans JT Welch M Whitehouse MR


The Bone & Joint Journal
Vol. 103-B, Issue 12 | Pages 1783 - 1790
1 Dec 2021
Montgomery S Bourget-Murray J You DZ Nherera L Khoshbin A Atrey A Powell JN

Aims

Total hip arthroplasty (THA) with dual-mobility components (DM-THA) has been shown to decrease the risk of dislocation in the setting of a displaced neck of femur fracture compared to conventional single-bearing THA (SB-THA). This study assesses if the clinical benefit of a reduced dislocation rate can justify the incremental cost increase of DM-THA compared to SB-THA.

Methods

Costs and benefits were established for patients aged 75 to 79 years over a five-year time period in the base case from the Canadian Health Payer’s perspective. One-way and probabilistic sensitivity analysis assessed the robustness of the base case model conclusions.


Bone & Joint Open
Vol. 2, Issue 9 | Pages 737 - 744
1 Sep 2021
Øhrn F Lian ØB Tsukanaka M Röhrl SM

Aims

Medial pivot (MP) total knee arthroplasties (TKAs) were designed to mimic native knee kinematics with their deep medial congruent fitting of the tibia to the femur almost like a ball-on-socket, and a flat lateral part. GMK Sphere is a novel MP implant. Our primary aim was to study the migration pattern of the tibial tray of this TKA.

Methods

A total of 31 patients were recruited to this single-group radiostereometric analysis (RSA) study and received a medial pivot GMK Sphere TKA. The distributions of male patients versus female patients and right versus left knees were 21:10 and 17:14, respectively. Mean BMI was 29 kg/m2 (95% confidence interval (CI) 27 to 30) and mean age at surgery was 63 years (95% CI 61 to 66). Maximum total point motions (MTPMs), medial, proximal, and anterior translations and transversal, internal, and varus rotations were calculated at three, 12, and 24 months. Patient-reported outcome measure data were also retrieved.


The Bone & Joint Journal
Vol. 103-B, Issue 9 | Pages 1479 - 1487
1 Sep 2021
Davis ET Pagkalos J Kopjar B

Aims

The aim of our study was to investigate the effect of asymmetric crosslinked polyethylene liner use on the risk of revision of cementless and hybrid total hip arthroplasties (THAs).

Methods

We undertook a registry study combining the National Joint Registry dataset with polyethylene manufacturing characteristics as supplied by the manufacturers. The primary endpoint was revision for any reason. We performed further analyses on other reasons including instability, aseptic loosening, wear, and liner dissociation. The primary analytic approach was Cox proportional hazard regression.


Aims

To report early (two-year) postoperative findings from a randomized controlled trial (RCT) investigating disease-specific quality of life (QOL), clinical, patient-reported, and radiological outcomes in patients undergoing a total shoulder arthroplasty (TSA) with a second-generation uncemented trabecular metal (TM) glenoid versus a cemented polyethylene glenoid (POLY) component.

Methods

Five fellowship-trained surgeons from three centres participated. Patients aged between 18 and 79 years with a primary diagnosis of glenohumeral osteoarthritis were screened for eligibility. Patients were randomized intraoperatively to either a TM or POLY glenoid component. Study intervals were: baseline, six weeks, six-, 12-, and 24 months postoperatively. The primary outcome was the Western Ontario Osteoarthritis Shoulder QOL score. Radiological images were reviewed for metal debris. Mixed effects repeated measures analysis of variance for within and between group comparisons were performed.


Bone & Joint Open
Vol. 2, Issue 6 | Pages 422 - 432
22 Jun 2021
Heath EL Ackerman IN Cashman K Lorimer M Graves SE Harris IA

Aims

This study aims to describe the pre- and postoperative self-reported health and quality of life from a national cohort of patients undergoing elective total conventional hip arthroplasty (THA) and total knee arthroplasty (TKA) in Australia. For context, these data will be compared with patient-reported outcome measures (PROMs) data from other international nation-wide registries.

Methods

Between 2018 to 2020, and nested within a nationwide arthroplasty registry, preoperative and six-month postoperative PROMs were electronically collected from patients before and after elective THA and TKA. There were 5,228 THA and 8,299 TKA preoperative procedures as well as 3,215 THA and 4,982 TKA postoperative procedures available for analysis. Validated PROMs included the EuroQol five-dimension five-level questionnaire (EQ-5D-5L; range 0 to 100; scored worst-best health), Oxford Hip/Knee Scores (OHS/OKS; range 0 to 48; scored worst-best hip/knee function) and the 12-item Hip/Knee disability and Osteoarthritis Outcome Score (HOOS-12/KOOS-12; range 0 to 100; scored best-worst hip/knee health). Additional items included preoperative expectations, patient-perceived improvement, and postoperative satisfaction. Descriptive analyses were undertaken.


The Bone & Joint Journal
Vol. 101-B, Issue 5 | Pages 502 - 511
1 May 2019
Lidder S Epstein DJ Scott G

Aims

Short-stemmed femoral implants have been used for total hip arthroplasty (THA) in young and active patients to conserve bone, provide physiological loading, and reduce the incidence of thigh pain. Only short- to mid-term results have been presented and there have been concerns regarding component malalignment, incorrect sizing, and subsidence. This systematic review reports clinical and radiological outcomes, complications, revision rates, and implant survival in THA using short-stemmed femoral components.

Materials and Methods

A literature review was performed using the EMBASE, Medline, and Cochrane databases. Strict inclusion and exclusion criteria were used to identify studies reporting clinical and radiological follow-up for short-stemmed hip arthroplasties.


Bone & Joint 360
Vol. 9, Issue 4 | Pages 30 - 33
1 Aug 2020


The Bone & Joint Journal
Vol. 102-B, Issue 9 | Pages 1158 - 1166
14 Sep 2020
Kaptein BL den Hollander P Thomassen B Fiocco M Nelissen RGHH

Aims

The primary objective of this study was to compare migration of the cemented ATTUNE fixed bearing cruciate retaining tibial component with the cemented Press-Fit Condylar (PFC)-sigma fixed bearing cruciate retaining tibial component. The secondary objectives included comparing clinical and radiological outcomes and Patient Reported Outcome Measures (PROMs).

Methods

A single blinded randomized, non-inferiority study was conducted including 74 patients. Radiostereometry examinations were made after weight bearing, but before hospital discharge, and at three, six, 12, and 24 months postoperatively. PROMS were collected preoperatively and at three, six, 12, and 24 months postoperatively. Radiographs for measuring radiolucencies were collected at two weeks and two years postoperatively.


Aims

To investigate the effect of polyethylene manufacturing characteristics and irradiation dose on the survival of cemented and reverse hybrid total hip arthroplasties (THAs).

Methods

In this registry study, data from the National Joint Registry of England, Wales, Northern Ireland and the Isle of Man (NJR) were linked with manufacturing data supplied by manufacturers. The primary endpoint was revision of any component. Cox proportional hazard regression was a primary analytic approach adjusting for competing risk of death, patient characteristics, head composition, and stem fixation.


Bone & Joint 360
Vol. 9, Issue 2 | Pages 27 - 30
1 Apr 2020


The Bone & Joint Journal
Vol. 101-B, Issue 11 | Pages 1431 - 1437
1 Nov 2019
Harrison-Brown M Scholes C Ebrahimi M Field C Cordingley R Kerr D Farah S Kohan L

Aims

It is not known whether change in patient-reported outcome measures (PROMs) over time can be predicted by factors present at surgery, or early follow-up. The aim of this study was to identify factors associated with changes in PROM status between two-year evaluation and medium-term follow-up.

Patients and Methods

Patients undergoing Birmingham Hip Resurfacing completed the Veteran’s Rand 36 (VR-36), modified Harris Hip Score (mHHS), Tegner Activity Score, and Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) at two years and a minimum of three years. A change in score was assessed against minimal clinically important difference (MCID) and patient-acceptable symptom state (PASS) thresholds. Binary logistic regression was used to assess the relationship between patient factors and deterioration in PASS status between follow-ups.


Bone & Joint 360
Vol. 8, Issue 4 | Pages 16 - 19
1 Aug 2019


Bone & Joint 360
Vol. 7, Issue 5 | Pages 2 - 7
1 Oct 2018
Palan J Bloch BV Shannak O James P


The Bone & Joint Journal
Vol. 101-B, Issue 1 | Pages 113 - 120
1 Jan 2019
Scholes CJ Ebrahimi M Farah SB Field C Cordingley R Kerr D Kohan L

Aims

The aim of this study was to report the implant survival and patient-reported outcome measures (PROMs) in a consecutive series of patients aged less than 50 years at the time of arthroplasty using the Birmingham Hip Resurfacing system (BHR), with a minimum follow-up of ten years.

Patients and Methods

A total of 226 patients with osteoarthritis of the hip, who underwent BHR and presented to a single surgeon, were included in the study. Survival of the implant was confirmed by cross-checking with the Australian Orthopaedic Association National Joint Replacement Registry. Kaplan–Meier survival curves with 95% confidence intervals (CIs) were constructed. Pre- and postoperative PROMs were compared with t-tests, and postoperative scores were compared using anchor analysis with age and gender matched normative data.


The Bone & Joint Journal
Vol. 100-B, Issue 11 | Pages 1424 - 1433
1 Nov 2018
Amstutz HC Le Duff MJ

Aims

This study presents the long-term survivorship, risk factors for prosthesis survival, and an assessment of the long-term effects of changes in surgical technique in a large series of patients treated by metal-on-metal (MoM) hip resurfacing arthroplasty (HRA).

Patients and Methods

Between November 1996 and January 2012, 1074 patients (1321 hips) underwent HRA using the Conserve Plus Hip Resurfacing System. There were 787 men (73%) and 287 women (27%) with a mean age of 51 years (14 to 83). The underlying pathology was osteoarthritis (OA) in 1003 (75.9%), developmental dysplasia of the hip (DDH) in 136 (10.3%), avascular necrosis in 98 (7.4%), and other conditions, including inflammatory arthritis, in 84 (6.4%).