header advert
Results 1 - 35 of 35
Results per page:
Bone & Joint Open
Vol. 3, Issue 9 | Pages 692 - 700
2 Sep 2022
Clement ND Smith KM Baron YJ McColm H Deehan DJ Holland J

Aims

The primary aim of our study was to assess the influence of age on hip-specific outcome following total hip arthroplasty (THA). Secondary aims were to assess health-related quality of life (HRQoL) and level of activity according to age.

Methods

A prospective cohort study was conducted. All patients were fitted with an Exeter stem with a 32 mm head on highly cross-linked polyethylene (X3RimFit) cemented acetabulum. Patients were recruited into three age groups: < 65 years, 65 to 74 years, and ≥ 75 years, and assessed preoperatively and at three, 12, 24, and 60 months postoperatively. Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC), Harris Hip Score (HHS), and Hip disability and Osteoarthritis Outcome Score (HOOS), were used to assess hip-specific outcome. EuroQol five-dimension five-level questionnaire (EQ-5D-5L) and 36-Item Short Form Survey (SF-36) scores were used to assess HRQoL. The Lower Extremity Activity Scale (LEAS) and Timed Up and Go (TUG) were used to assess level of activity.


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_4 | Pages 24 - 24
1 Apr 2022
Partridge T Osborne S Marsh M Holland J
Full Access

We present a consecutive case cohort of the first 100 Birmingham Hip Resurfacing (BHR)'s in 90 patients with a minimum follow up of 20 years. All procedures were performed by a single surgeon having commenced the study in 1998.

The original cohort included 68 males with 75 hips (7 bilateral) and 22 females with 25 hips (3 bilateral). The mean age at index procedure was 52. Patients were recalled to review in clinic as per Medicines and Healthcare products Regulatory Agency guidelines with x-rays, metal ions and Harris Hip Scores recorded.

After a minimum of 20 year follow-up review the known overall revision rate is 11%. 11 have died and 7 have been lost to review. In males the known revision rate is 4/75 (5%), 3 of which were due to early fractures and 1 revision for infection at 5 years. The known revision rate in females is 7/25 (28%) of which 6 were due to adverse reactions to metal debris; 3 at 7–8 yrs, 1 at 15 yrs, 2 at 18 years, and 1 at 2 months for avascular necrosis. The mean 20 year metal ions results were cobalt 36.6 nmol/l (range 7.4–232.1) and chromium 32.1 nmol/l (range 6–120.8). The mean Harris hip score was 88.5 (range 38.6–99.8).

This case series with 20 years follow-up demonstrates excellent long term survival of the BHRs further to registry BHR data and similar to THR for same age recipients. Applying today's strict criteria for patient selection would likely improve survival rate further. BHR has not demonstrated the catastrophic revision rates associated with some metal-on-metal resurfacing and remains a safe option for those who meet the criteria.


The Bone & Joint Journal
Vol. 102-B, Issue 1 | Pages 125 - 131
1 Jan 2020
Clement ND Weir DJ Holland J Deehan DJ

Aims

The primary aim of this study was to assess whether pain in the contralateral knee had a clinically significant influence on the outcome of total knee arthroplasty (TKA) according to the Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) score. Secondary aims were to: describe the prevalence of contralateral knee pain; identify if it clinically improves after TKA; and assess whether contralateral knee pain independently influences patient satisfaction with their TKA.

Methods

A retrospective cohort of 3,178 primary TKA patients were identified from an arthroplasty database. Patient characteristics, comorbidities, and WOMAC scores were collected preoperatively and one year postoperatively for the index knee. In addition, WOMAC pain scores were also collected for the contralateral knee. Overall patient satisfaction was assessed at one year. Preoperative contralateral knee pain was defined according to the WOMAC score: minimal (> 78 points), mild (59 to 78), moderate (44 to 58), and severe (< 44). Multivariate regression analysis was used to adjust for confounding.


Bone & Joint Research
Vol. 8, Issue 6 | Pages 246 - 252
1 Jun 2019
Liddle A Webb M Clement N Green S Liddle J German M Holland J

Objectives

Previous studies have evidenced cement-in-cement techniques as reliable in revision arthroplasty. Commonly, the original cement mantle is reshaped, aiding accurate placement of the new stem. Ultrasonic devices selectively remove cement, preserve host bone, and have lower cortical perforation rates than other techniques. As far as the authors are aware, the impact of ultrasonic devices on final cement-in-cement bonds has not been investigated. This study assessed the impact of cement removal using the Orthosonics System for Cemented Arthroplasty Revision (OSCAR; Orthosonics) on final cement-in-cement bonds.

Methods

A total of 24 specimens were manufactured by pouring cement (Simplex P Bone Cement; Stryker) into stainless steel moulds, with a central rod polished to Stryker Exeter V40 specifications. After cement curing, the rods were removed and eight specimens were allocated to each of three internal surface preparation groups: 1) burr; 2) OSCAR; and 3) no treatment. Internal holes were recemented, and each specimen was cut into 5 mm discs. Shear testing of discs was completed by a technician blinded to the original grouping, recording ultimate shear strengths. Scanning electron microscopy (SEM) was completed, inspecting surfaces of shear-tested specimens.


Bone & Joint Research
Vol. 8, Issue 6 | Pages 275 - 287
1 Jun 2019
Clement ND Bardgett M Merrie K Furtado S Bowman R Langton DJ Deehan DJ Holland J

Objectives

Our primary aim was to describe migration of the Exeter stem with a 32 mm head on highly crosslinked polyethylene and whether this is influenced by age. Our secondary aims were to assess functional outcome, satisfaction, activity, and bone mineral density (BMD) according to age.

Patients and Methods

A prospective cohort study was conducted. Patients were recruited into three age groups: less than 65 years (n = 65), 65 to 74 years (n = 68), and 75 years and older (n = 67). There were 200 patients enrolled in the study, of whom 115 were female and 85 were male, with a mean age of 69.9 years (sd 9.5, 42 to 92). They were assessed preoperatively, and at three, 12 and, 24 months postoperatively. Stem migration was assessed using Einzel-Bild-Röntgen-Analyse (EBRA). Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC), Harris Hip Score (HHS), Hip Disability and Osteoarthritis Outcome Score (HOOS), EuroQol-5 domains questionnaire (EQ-5D), short form-36 questionnaire (SF-36,) and patient satisfaction were used to assess outcome. The Lower Extremity Activity Scale (LEAS), Timed Up and Go (TUG) test, and activPAL monitor (energy expelled, time lying/standing/walking and step count) were used to assess activity. The BMD was assessed in Gruen and Charnley zones.


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_6 | Pages 1 - 1
1 May 2019
Watkins C Ghosh K Bhatnagar S Rankin K Weir D Hashmi M Holland J
Full Access

Background

Total hip arthroplasty (THA) in patients with congenital dysplasia of the hip (CDH) is complex and challenging. The Crowe and Hartofilakidis classification systems are the most commonly used. However, neither encompasses the whole spectrum of disease and deformity and therefore does not guide modern surgical options.

We present a new classification system which aims to guide surgical strategy by focusing on the three main areas of disease and deformity: Cup defect; De-rotation of femoral neck ante-version; Height of femoral subluxation. Each component is graded from 1–3 based on the severity of deformity and the potential surgical strategy required (with 3 being the most severe). A total numerical score will reflect the overall degree of difficulty which may be used when assessing surgical outcomes.

The aim of this study is to assess the reliability of this new adult CDH classification system in the setting of THA.

Study design and Methods

A sample size calculation showed 28 evaluations were required to reach a power of 85% (based on a kappa value of 0.4). The anterior-posterior pelvis and lateral hip radiographs of 30 hips, in 26 patients were evaluated by three Consultant Orthopaedic Surgeons using the classification detailed in table 1. A second evaluation, with the case order randomised, was performed after a minimum period of 1month. Randolph's free multi-rater Kappa co-efficient was used to assess for inter and intra- observer reliability and 95% confidence intervals were calculated.


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_6 | Pages 25 - 25
1 May 2019
Langton D Sidaginamale R Wells S Wainwright B Holland J Deehan D Joyce T Jafri A Nargol A Natu S
Full Access

Introduction

We aimed to identify genes associated with the development of ALVAL at relatively low levels of wear.

Methods

At our unit all patients undergoing revision of a MoM hip prosthesis have periprosthetic tissue samples graded for ALVAL. Explants undergo volumetric wear testing of the bearing and taper surfaces. We identified patients with moderate/severe ALVAL who had been exposed to lower than the median wear rate of all recorded patients who had developed ALVAL (<3mm3/year). This was termed the “ALVAL” group. We then identified all patients whose tissues had shown no signs of ALVAL. The patients in the two groups were sent buccal DNA collection kits. DNA was examined using next generation sequencing. Alleleic frequencies in the two groups were compared using Fisher's test and compared to a background UK population group (n=8514). We then conducted binary logistic regression with patient age, sex, primary source of debris (taper/bearing) and HLA genotype as the predictors. With the hypothesis that a cobalt/albumin metalloprotein acts as the epitope, we used validated binding prediction software to determine the relative affinities of the binding grooves created by different DQA1/DQB1 genetic combinations for albumin derived peptides. Given the protection that male sex and younger age appears to confer against ALVAL, we hypothesized that testosterone peptides may compete for these binding sites.


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_5 | Pages 110 - 110
1 Apr 2019
Farrier A Manning W Moore L Avila C Collins S Holland J
Full Access

INTRODUCTION

Experience with Metal on Metal (MoM) hip resurfacing devices has shown adequate cementation of the femoral head is critical for implant survival. Bone necrosis can be caused by the temperature change in the peri-prosthetic bone whilst the cement cures during implantation. This can lead to implant loosening, head/neck fracture and implant failure. During the implantation it is known that implants change shape potentially altering joint clearance and causing loosening.

Given the history of Metal on Metal implant failure due adverse tissue reactions from Cobalt and Chromium particles we sought to test a novel Ceramic on Ceramic (CoC) bearing which may mitigate such problems.

AIM

We set out to compare the behaviour of a novel ceramic femoral head component to a standard metal component in a hip resurfacing system after cemented implantation in a physiological warmed cadaveric model.

Our first aim was to perform heat transfer analysis: To document time to, and extent of, maximum temperature change on the metal/ceramic surface and inside the resurfaced femoral head bone.

Our second aim was to perform a dimensional analysis: To document any resulting deformation in the metal/ceramic femoral head bearing diameter during cementation.


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_5 | Pages 112 - 112
1 Apr 2019
Farrier A Manning W Moore L Avila C Collins S Holland J
Full Access

INTRODUCTION

The cup component of modern resurfacing systems are often coated creating a cementless press-fit fixation in the acetabulum based on surgical under-reaming, also enabling osseoconduction/integration. Due to the higher density of cortical bone along the antero-superior and postero-inferior regions of the acetabulum, the greatest forces occur between the anterior and posterior columns of the pelvis. This produces pinching of the implant that can result in deformation of the cup. Metal shell/modularpress-fit acetabular cups are susceptible to substantial deformation immediately after implantation. This deformation may affect the lubrication, producing point loading and high friction torques between the head and the cup that increase wear and may lead to head clamping and subsequent cup loosening. We sought to test a novel ceramic on ceramic (CoC) hip resurfacing system that should allay any concerns with the Adverse Reaction to Metal Debris associated with metal on metal (MoM) resurfacing devices.

AIM

We sought to quantify the deformation of a novel CoC hip-resurfacing cup after implantation, using a standard surgical technique in a cadaveric model, and compare to the MoM standard. We also assessed if the design clearances proposed for this CoC hip resurfacing implant are compatible with the measured deformations, allowing for an adequate motion of the joint.


The Bone & Joint Journal
Vol. 100-B, Issue 6 | Pages 740 - 748
1 Jun 2018
Clement ND Bardgett M Weir D Holland J Gerrand C Deehan DJ

Aims

The primary aim of this study was to assess the rate of patient satisfaction one year after total knee arthroplasty (TKA) according to the focus of the question asked. The secondary aims were to identify independent predictors of patient satisfaction according to the focus of the question.

Patients and Methods

A retrospective cohort of 2521 patients undergoing a primary unilateral TKA were identified from an established regional arthroplasty database. Patient demographics, comorbidities, Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) and 12-Item Short-Form Health Survey (SF-12) scores were collected preoperatively and one year postoperatively. Patient satisfaction was assessed using four questions, which focused on overall outcome, activity, work, and pain. Logistic regression analysis was used to identify independent preoperative predictors of increased stiffness when adjusting for confounding variables.


The Bone & Joint Journal
Vol. 100-B, Issue 2 | Pages 161 - 169
1 Feb 2018
Clement ND Bardgett M Weir D Holland J Gerrand C Deehan DJ

Aims

The primary aim of this study was to assess whether patient satisfaction one year after total knee arthroplasty (TKA) changed with longer follow-up. The secondary aims were to identify predictors of satisfaction at one year, persistence of patient dissatisfaction, and late onset dissatisfaction in patients that were originally satisfied at one year.

Patients and Methods

A retrospective cohort consisting of 1369 patients undergoing a primary TKA for osteoarthritis that had not undergone revision were identified from an established arthroplasty database. Patient demographics, comorbidities, Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) scores, and Short Form 12 (SF-12) questionnaire scores were collected preoperatively, and one and five years postoperatively. In addition, patient satisfaction was assessed at one and five years postoperatively. Logistic regression analysis was used to identify independent predictors of satisfaction at one and five years.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_12 | Pages 4 - 4
1 Jun 2017
Liddle A German M Green S Townsend A Webb M Holland J
Full Access

Numerous studies have evidenced cement-in-cement techniques as reliable in revision arthroplasty. The original cement mantle is commonly reshaped to aid accurate placement of the new stem.

Ultrasonic devices selectively remove cement, preserve host bone and have lower cortical perforation rates than other techniques. As far as the authors are aware, their impact on final cement-cement bonds has not been investigated. This study assessed the impact of cement removal using OSCAR (Orthosonics System for Cemented Arthroplasty Revision, ORTHOSONICS) on final cement-cement bonds.

Twenty-four specimens were manufactured by pouring cement (Simplex P Bone Cement, Stryker) into stainless-steel moulds with a central rod polished to Stryker Exeter V40 specifications. After cement curing, rods were removed and eight specimens allocated to each of three internal surface preparation groups: 1) burr; 2) OSCAR; or 3) no treatment. Internal holes were re-cemented, then each specimen was cut into 5mm discs. Shear testing of discs was completed by a technician blinded to original grouping (Instron 5567, UK), recording ultimate shear strengths.

The mean shear strength for OSCAR-prepared specimens (17 MPa, 99% CI 14.9 to 18.6, SD=4.0) was significantly lower than that measured for the control (23 MPa, 99% CI 22.5 to 23.7, SD=1.4) and burr (23 MPa, 99% CI 22.1 to 23.7, SD=1.9) groups (P<0.001, one-way ANOVA with Tukey's post-hoc analysis). There was no significant difference between control and burr groups (P>0.05).

Results show that cement removal technique impacts on final cement-cement bonds. This in vitro study shows a significantly weaker bond when using OSCAR prior to re-cementation into an old cement mantle, compared to cement prepared with a burr or no treatment.

These results have implications for surgical practice and decision-making about specific cement removal techniques used during cement-in-cement revision arthroplasty, suggesting that the risks and benefits of ultrasonic cement removal need careful consideration.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_12 | Pages 12 - 12
1 Jun 2017
Holland J Deehan D Manning W Pandorf T
Full Access

Modular un-cemented acetabular components are used in over 50% of UK hip replacements. Mal-seating of hard liners has been reported as a cause of failure which may be a result of errors in assembly, but also could be affected by deformation of the acetabular shell on insertion. Little information exists on in vivo shell deformation. Previous work has confirmed the importance of shell diameter and thickness upon shell behaviour, but mostly using single measurements in models or cold cadavers.

Exploration of deformation and its relaxation over the first twenty minutes after implantation of eight generic metal cups at body temperature.

Using a previously validated cadaveric model at controlled physiological temperature with standardised surgical technique, we tested the null hypothesis that there was no consistency for time dependent or directional change in deformation for a standard metal shell inserted under controlled conditions into the hip joint. Eight custom made titanium alloy (TiAl6V4) cups were implanted into 4 cadavers (8 hips). Time dependent cup deformation was determined using the previously validated ATOS Triple Scan III (ATOS) optical measurement system. The pattern of change in the shape of the surgically implanted cup was measured at 3 time points after insertion.

We found consistency for quantitative and directional deformation of the shells. There was consistency for relaxation of the deformation with time. Immediate mean change in cup radius was 104μm (sd 32, range 67–153) relaxing to mean 96 μm (sd 32, range 63–150) after 10 minutes and mean 92 μm (sd 28, range 66–138) after 20 minutes.

This work shows the time dependent deformation and relaxation of acetabular titanium shells and may aid determining the optimal time for insertion of the inner liner at surgery.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_8 | Pages 23 - 23
1 Apr 2017
Lawrence H Deehan D Holland J Kirby J Tyson-Capper A
Full Access

Background

Metal-on-metal (MoM) hip arthroplasty has been associated with adverse reactions including pseudotumours, and osteolysis. Tissues surrounding failed MoM hip implants are often infiltrated by inflammatory cells such as monocytes and neutrophils. The mechanisms by which these cells are recruited to the tissues remain unclear. Cobalt from MoM implants activates Toll-like receptor 4 (TLR4), an immune cell surface receptor usually responsible for recognition of bacteria and prevention of sepsis. Activation by bacteria leads to secretion of pro-inflammatory cytokines which guide other immune cells to the site of inflammation. The effect of cobalt on this response is unknown and therefore this study aims to determine the effect of cobalt-mediated TLR4 activation on the migration of inflammatory cells.

Methods

A human macrophage cell line (MonoMac 6) was stimulated with a physiologically-relevant range of cobalt ions for 24h with or without pre-treatment with a TLR4 antagonist. Conditioned media was collected and used in a trans-well migration assay to determine its effect on migration of primary monocytes and neutrophils isolated from whole human blood. Migrated cells were stained with haematoxylin and counted at ×40 magnification.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_11 | Pages 4 - 4
1 Jun 2016
O'Hare J Langton D Nargol A Joyce T Brewster N Cooke N Jafri A Lord J Duffy P Holland J
Full Access

Introduction

Historical studies have reported incidences of taper corrosion in retrieved MoP hips of 20–50%. These studies relied on visual assessments, rather than using modern analytical techniques.

Patients/Materials and Methods

The Northern Retrieval Registry was initiated to routinely analyse all retrieved hips. The volumetric wear rates of retrieved Exeter head tapers were measured using a coordinate measuring machine using validated methods and compared to the available results obtained from an ongoing study of failed MoM prostheses. Power analysis suggested that we would need at least fifty Exeter head tapers to provide significant results. Non-parametric tests were used to assess differences. We have previously identified head diameter/offset/taper angle and taper surface roughness as variables associated with taper wear. The effect of bearing material combination remains unquantified. These design variables were entered into a multiple regression model following log normalisation of taper wear.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_7 | Pages 115 - 115
1 May 2016
Dold P Pandorf T Flohr M Preuss R Bone M Holland J Deehan D
Full Access

INTRODUCTION

Deformation of modular acetabular press-fit shells is of much interest for surgeons and manufacturers. Initial fixation is achieved through press-fit between shell and acetabulum with the shell mechanically deforming upon insertion. Shell deformation may disrupt the assembly process of modular systems and may adversely affect integrity and durability of the components and tribology of the bearing. The aim of the study was to show shell deformation as a function of bone and shell stiffness.

METHODS

The stiffness of the generic shells was determined using a uniaxial/ two point loading frame by applying different loads, and the change in dimension was measured by a coordinate measurement machine (CMM). Cadaver lab deformation measurements were done before and after insertion for 32 shells with 2 wall thicknesses and 11 shell sizes using the ATOS Triple Scan III (ATOS) optical system previously validated as a suitable measurement system to perform those measurements. Multiple deformation measurements per cadaver were performed by using both hip sides and stepwise increasing the reamed acetabulum by at least 1 mm, depending on sufficient residual bone stock. The under-reaming was varied between 0mm and 1mm, respectively. From the deformations, the resulting forces on the shells and bone stiffness were calculated assuming force equilibrium as well as linear-elastic material behaviour in each point at the rim of the shell.


The Bone & Joint Journal
Vol. 98-B, Issue 3 | Pages 313 - 319
1 Mar 2016
Baker P Rankin K Naisby S Agni N Brewster N Holland J

Aims

The highly cross-linked polyethylene Exeter RimFit flanged cemented acetabular component was introduced in the United Kingdom in 2010. This study aimed to examine the rates of emergence of radiolucent lines observed when the Rimfit acetabular component was implanted at total hip arthroplasty (THA) using two different techniques: firstly, the ‘rimcutter’ technique in which the flange sits on a pre-prepared acetabular rim; and secondly, the ‘trimmed flange’ technique in which the flange is trimmed and the acetabular component is seated inside the rim of the acetabulum.

Patients and Methods

The radiographs of 150 THAs (75 ‘rimcutter’, 75 ‘trimmed flange’) involving this component were evaluated to assess for radiolucencies at the cement/bone interface by three observers.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_1 | Pages 114 - 114
1 Jan 2016
Dold P Bone M Flohr M Preuss R Joyce TJ Deehan D Holland J
Full Access

INTRODUCTION

Deformation of modular acetabular press-fit shells is a topic of much interest for surgeons and manufacturer. Such modular components utilise a titanium shell with a liner manufactured from metal, polyethylene or ceramic. Initial fixation is achieved through a press-fit between shell and acetabulum with the shell mechanically deforming upon insertion. Shell deformation may disrupt the assembly process of inserting the bearing liner into the acetabular shell for modular systems. This may adversely affect the integrity and durability of the components and the tribology of the bearing.

OBJECTIVE

Most clinically relevant data to quantify and understand such shell deformation can be achieved by cadaver measurements. ATOS Triple Scan III was identified as a measurement system with the potential to perform those measurements. The study aim was to validate an ATOS Triple Scan III optical measurement system against a co-ordinate measuring machine (CMM) using in-vitro testing and to check capability/ repeatability under cadaver lab conditions.


The Bone & Joint Journal
Vol. 97-B, Issue 4 | Pages 473 - 477
1 Apr 2015
Bone MC Dold P Flohr M Preuss R Joyce TJ Aspden RM Holland J Deehan D

Concerns have been raised that deformation of acetabular shells may disrupt the assembly process of modular prostheses. In this study we aimed to examine the effect that the strength of bone has on the amount of deformation of the acetabular shell. The hypothesis was that stronger bone would result in greater deformation. A total of 17 acetabular shells were inserted into the acetabula of eight cadavers, and deformation was measured using an optical measuring system. Cores of bone from the femoral head were taken from each cadaver and compressed using a materials testing machine. The highest peak modulus and yield stress for each cadaver were used to represent the strength of the bone and compared with the values for the deformation and the surgeon’s subjective assessment of the hardness of the bone. The mean deformation of the shell was 129 µm (3 to 340). No correlation was found between deformation and either the maximum peak modulus (r² = 0.011, t = 0.426, p = 0.676) or the yield stress (r² = 0.024, t = 0.614, p = 0.549) of the bone. Although no correlation was found between the strength of the bone and deformation, the values for the deformation observed could be sufficient to disrupt the assembly process of modular acetabular components.

Cite this article: Bone Joint J 2015; 97-B:473–7.


The Bone & Joint Journal
Vol. 96-B, Issue 9 | Pages 1172 - 1177
1 Sep 2014
Lawrence H Deehan D Holland J Kirby J Tyson-Capper A

Abnormal wear of cobalt-containing metal-on-metal joints is associated with inflammatory pseudotumours. Cobalt ions activate human toll-like receptor 4 (TLR4), which normally responds to bacterial lipopolysaccharide (LPS) in sepsis. Activation of TLR4 by LPS increases the expression of chemokines IL-8 and CXCL10, which recruit leukocytes and activated T-cells, respectively. This study was designed to determine whether cobalt induces a similar inflammatory response to LPS by promoting the expression of IL-8 and CXCL10. A human monocytic cell line, derived from acute monocytic leukaemia, was treated with cobalt ions and expression of IL-8 and CXCL10 measured at mRNA and protein levels. Cobalt-treated macrophages showed a 60-fold increase in IL-8 mRNA, and an eightfold increase in production of the mature chemokine (both p < 0.001); expression of the CXCL10 gene and protein was also significantly increased by cobalt (both p < 0.001). Experiments were also performed in the presence of CLI-095, a TLR4-specific antagonist which abrogated the cobalt-mediated increase in IL-8 and CXCL10 expression.

These findings suggest that cobalt ions induce inflammation similar to that observed during sepsis by the simultaneous activation of two TLR4-mediated signalling pathways. These pathways result in increased production of IL-8 and CXCL10, and may be implicated in pseudotumour formation following metal-on-metal replacement.

Cite this article: Bone Joint J 2014; 96-B:1172–7.


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_11 | Pages 292 - 292
1 Jul 2014
Lawrence H Deehan D Holland J Kirby J Tyson-Capper A
Full Access

Summary

Metal-on-metal hip replacements have been associated with adverse reactions including inflammatory pseudotumours and soft tissue necrosis. We have shown that cobalt can directly activate toll-like receptor 4, an immune receptor causing pro-inflammatory interleukin-8 secretion. This may contribute to adverse reaction development.

Introduction

Metal-on-metal hips have the highest failure rate of any joint arthroplasty material. Reasons for failure include the development of pseudotumours, soft tissue necrosis and pain around the affected joint. The adverse reactions appear to be inflammatory as failing joints are often infiltrated by immune cells such as lymphocytes. However the exact cellular and biological mechanisms underlying this inflammation are unknown. Toll-like receptor 4 (TLR4) is found on the surface of immune cells including macrophages and dendritic cells. It is activated by lipopolysaccharide (LPS) from Gram negative bacteria, inducing an immune response against the pathogen through increased secretion of pro-inflammatory cytokines. It has recently been shown that nickel can activate TLR4, causing inflammation. Cobalt, a component of many metal-on-metal joints, is adjacent to nickel in the periodic table and shares a number of nickel's properties. Consequently we hypothesised that cobalt ions from metal-on-metal joints can activate TLR4.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXIX | Pages 83 - 83
1 Sep 2012
Malviya A Brewster N Weir D Holland J Deehan D
Full Access

Purpose

Although classic teaching holds that the least amount of constraint should be implanted, there is very little in the literature to substantiate this. This study attempts to quantify the influence of constraint and various indications upon functional outcome following aseptic first time revision knee arthroplasty. The null hypothesis was that the level of constraint and indication for surgery would not influence the functional outcome following revision knee replacement.

Methods

A single centre prospective study was performed to examine the outcome for 175 consecutive total revision knee replacements performed between 2003 and 2008 with a minimum follow-up of two years. Patient reported outcome data was used to determine the influence of final level of component constraint and its relationship with primary indication for surgery.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXIX | Pages 1 - 1
1 Sep 2012
Ramaskandhan J Malviya A Bowman R Lingard E Holland J
Full Access

Introduction

Cemented stems have shown 90–100% survivorship when coupled with polyethylene acetabular component. This study aims to compare cemented stem behaviour in combination with large metal on metal (MOM) vs. metal on poly (MOP) bearings.

Patients and Methods

100 patients were recruited into a single centre RCT (we required 40 in each group for power .90 to confirm stem subsidence of >0.5mm at 2 years; p< 0.05). Recruits were randomized to MOP (28mm) or MOM femoral heads with CPCS cemented femoral stem. Assessments included X-rays (AP pelvis), Harris Hip Scores, blood metal ion levels and patient questionnaires (WOMAC, SF-36, satisfaction questionnaire). Evaluations were done pre-operatively and 3, 12 and 24 months post operatively; blood metal ion measures at 1 year.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXIX | Pages 57 - 57
1 Jul 2012
Malviya A Brewster N Weir D Holland J Deehan D
Full Access

Introduction

We wished to quantify the influence of constraint and various principal indications upon functional outcome following aseptic first time revision knee arthroplasty.

Methods

In this single centre, prospective study we have looked into the outcome of 175 total revision knee replacement performed between 2003 and 2008 at a minimum follow-up of 1 year. Data was refined to allow for examination exclusively of those cases where the level of constraint was increased from cruciate retaining or cruciate sacrificing knee replacement to either non linked constrained implant (condylar constrained) or linked constrained (rotating hinge) prosthesis.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_IV | Pages 123 - 123
1 Mar 2012
Reay E Wu J Sarah G Deehan D Holland J
Full Access

During a retrospective case note analysis, a significant difference was found in prosthesis survival, between two cohorts of patients who underwent different total knee replacements. The first cohort included 70 patients who underwent Kinemax Plus total knee replacement, the second cohort included 58 patients who underwent PFC Total Knee replacement. All patients were under the care of one Consultant Orthopaedic Surgeon. Interestingly, the Kinemax Plus cohort was found to have a higher rate of revision compared to the PFC cohort. A detailed comparison was carried out between the two groups to identify any obvious cause for the disparity.

The two cohorts were found to be well matched with respect to age, sex, ASA grade, underlying pathology and operative technique. Median follow up being 6 years and 5 years for the Kinemax Plus and PFC groups respectively.

There were 11 failed prostheses in the Kinemax Plus cohort, 7 undergoing revision with the remaining 4 patients offered revision but unwilling to have surgery. Wear of the polyethylene tibial insert was the most obvious finding at revision, present in six of the seven revisions. 97% of the Kinemax Plus Prostheses were intact at 5 years but by 8 years only 87% were intact. There were no revisions performed in the PFC cohort.

Post-operative x-ray analysis was undertaken to rule out prosthesis malalignment as a cause for the increased failure rate. The coronal alignment of the prostheses (CAK) was calculated and all post operative x-rays were within the normal limits of 4-10 degrees.

Analysis of the explanted Kinemax Plus polyethylene liners was undertaken. In six cases, the polyethylene bearing surfaces displayed severe surface and subsurface delamination. This suggests massive fatigue and fatigue wear. Only one implant showed localised delamination.

These findings suggest the hypothesis of weak polyethylene particle interface strength.


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_III | Pages 286 - 286
1 Jul 2011
Inman D Lingard E Brewster N Deehan D Holland J Mccaskie A Siddique M Gerrand C
Full Access

Introduction and Aims: Morbid obesity (BMI> 40) has been shown to cause increased perioperative morbidity and poorer long-term implant survivorship following total knee arthroplasty (TKA). The aim of this study was to determine the impact of morbid obesity on patient-reported outcomes following TKA.

Methods: Patients undergoing primary TKA were invited to complete questionnaires preoperatively and one year after surgery. Questionnaires include the WOMAC and SF-36 health status measures, demographics, self-reported comorbid medical conditions, height and weight. At follow-up, satisfaction with results of TKA is included. Patients were categorised by their preoperative BMI categories as ideal weight (20–25), overweight (> 25–30), obese (> 30–40) or morbidly obese (> 40). We used multivariate analysis to adjust for known significant correlates of WOMAC and SF-36, namely age, gender and comorbid medical conditions. Adjusted mean scores for each assessment were compared by BMI category.

Results: A total of 769 patients were included in the study which included 27 morbidly obese, 280 obese, 314 overweight and 148 ideal weight patients. Morbidly obese patients when compared with non-obese patients had significantly worse preoperative WOMAC pain and function and a trend for worse SF36 scores (Vitality significantly worse, p=0.04). There was no significant difference between the BMI categories at one year for WOMAC or SF-36 scores (trend for the Physical Functioning score to be lower, p=0.052). Morbidly obese patients were all satisfied with pain relief after surgery but were less satisfied with functional results when compared to the non-obese groups.

Discussion: This study shows that morbidly obese patients report significantly worse health status prior to TKA but their post-operative improvement is greater than the non-obese population. Although morbid obesity should not be an absolute contraindication to TKA, patients should be carefully selected balancing the risk of perioperative complications and earlier failure against the demonstrated marked improvement in quality of life.


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_III | Pages 398 - 398
1 Jul 2010
Bhatnagar S Langton D Aval S Holland J Nargol A
Full Access

Background: Resurfacing cups may produce significant clinical problems when placed at the extremes of version, including increased production of metal debris and psoas tendonitis.

Methods: We obtained the femoral and acetabular components of two unused ASR (Articular Surface Replacement) and BHR (Birmingham Hip Resurfacing) devices. The components were placed in moulds at varying degrees of inclination and anteversion in a grid to simulate pelvic landmarks and AP radiographic images were captured. The true radiological anteversion was determined by rotating the x-ray beam so that it was perpendicular to the acetabular axis and measuring the angle subtended by the cup rim and the vertical axis.

Five blinded orthopaedic registrars then used EBRA (Einzel-Bild-Roentgen-Analysis, University of Inns-bruck, Austria) software to determine the radiological anteversion from the AP films. Twenty-five ASR and twenty-five BHR images were analysed.

At the same time each observer was asked to grade the cups as “1” (< 10°) “2” (10–20°) “3” (20–30°) or “4” (> 30°) depending on the appearances of the cup vertices.

Results: Mean error for each observer was −0.7 (minimum) to 1.6° (maximum). The range of standard deviations of error for each observer was +/− 2.2 (minimum) to 3.5° (maximum). Retroverted cups were not identified in the majority of cases.

Cups graded as “1” or “4” showed high sensitivity and specificity for the true grade as determined on the lateral radiographs.

Conclusions: EBRA software can be used to calculate the anteversion of resurfacing cups to a clinically acceptable degree. The clinician must be aware of the limitations of the software most notably the difficulty in identifying a retroverted cup and errors arising from poor quality radiographs in terms of pelvic rotation. The presented clinical grading system can be used as a rapid assessment tool to identify cups at the extremes of anteversion.


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_III | Pages 407 - 407
1 Jul 2010
Wu J Augustine A Deehan D Holland J Reay E
Full Access

The Kinemax Plus knee replacement has a reported 10 year survival of around 96%. However we found the survival rate of this implant in our cohort to be 75% at 9 years. No abnormalities were found for clinical and radiological parameters. At reoperation the most striking feature was that of significant ultra-high molecular weight polyethylene (UHMWPE) failure. Oxidative and structural analysis of the polyethylene components was therefore undertaken.

Ten Kinemax Plus tibial inserts were analysed; one was a shelf-aged unused implant, the others were explants. An FTIR analysis of the data showed that oxidation is present in all samples. The degree of oxidation however varied with depth and location. Except for a sharp oxidative peak approximately half way into the sample, the shelf aged samples had a fairly constant level of oxidation. The retrieved implants had an overall higher level of oxidation in both bearing and non-bearing regions. The latter had less of a variation in oxidation which implies that in vivo loading exaggerates the degree of oxidation. In the non-articulating regions oxidation of the explants was found to peak often at the region of about 40% from the bottom surface in all retrieved samples. By contrast, most articulating region had two oxidative peaks; one occurring at approximately 1–1.5mm from the surface, which is consistent with findings on subsurface oxidation, and another occurring about 2–3mm from the bottom surface.

SEM imaging provided evidence for the presence of fusion defects by indicating grain boundaries through-out the explants. This indicates a compromised material which is more susceptible to damage. Fatigue loading of the implant has also been seen to produce a subsurface stress maximum at approximately 1 to 2mm below the articulating surface. It is thought that maximum contact stresses within this region cause Type 1 and Type 2 defects to open or become more pronounced. This in turn will increase the local concentration of oxygenating material as it will be present in these defects and voids where surface areas are greater for oxidative reaction. We therefore hypothesise that these fusion defects are the cause for the early failure of the Kinemax implants.


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_III | Pages 422 - 422
1 Jul 2010
Reay E Wu J Holland J Deehan D
Full Access

We aim to explain the significant difference in survivor-ship found between two cohorts of patients who underwent different total knee replacements. The first cohort included 70 patients who underwent Kinemax Plus total knee replacement, the second cohort included 58 patients who underwent PFC Total Knee replacement. All patients were under the care of one Consultant Orthopaedic Surgeon.

Interestingly, the Kinemax Plus cohort was found to have a higher rate of revision as compared to the PFC cohort. A detailed comparison was then carried out between the two groups to identify any obvious cause for the disparity.

The two cohorts were found to be well matched with respect to age, sex, ASA grade, underlying pathology and operative technique. Median follow up being 6 years and 5 years for the Kinemax and PFC groups respectively. There were 11 failed prostheses in the kinemax cohort, 7 undergoing revision with the remaining 4 patients offered revision but unwilling have surgery. Wear of the polyethylene tibial insert was the most obvious finding at revision, present in six out of the 7 revisions. 97% of the Kinemax Plus Prostheses were intact at 5 years but by 8 years only 87% were intact.

There were no revisions performed in the PFC cohort.

Post operative x-ray analysis was undertaken to rule out prosthesis misalignment as a cause for the increased failure rate. The coronal alignment of the prostheses (CAK) was calculated and all post operative x-rays were within the normal limits of 4–10 degrees.

Analysis of the explanted Kinemax Plus polyethylene liners was undertaken. In six cases, the polyethylene bearing surfaces displayed severe surface and subsurface delamination at both medial and lateral sides. This suggests massive fatigue and fatigue wear. Only one inplant showed localised delamination. The surface characterisation suggests the hypothesis of weak UHMWPE particle interface strength.


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 5 | Pages 604 - 611
1 May 2009
Reay E Wu J Holland J Deehan D

We describe a cohort of patients with a high rate of mid-term failure following Kinemax Plus total knee replacement inserted between 1998 and 2001. This implant has been recorded as having a survival rate of 96% at ten years. However, in our series the survival rate was 75% at nine years. This was also significantly lower than that of subsequent consecutive series of PFC Sigma knee replacements performed by the same surgeon. No differences were found in the clinical and radiological parameters between the two groups. At revision the most striking finding was polyethylene wear. An independent analysis of the polyethylene components was therefore undertaken. Scanning electron microscopy revealed type 2 fusion defects in the ultra-high molecular weight polyethylene (UHMWPE), which indicated incomplete boundary fusion. Other abnormalities consistent with weak UHMWPE particle interface strength were present in both the explanted inserts and in unused inserts from the same period.

We consider that these type 2 fusion defects are the cause of the early failure of the Kinemax implants. This may represent a manufacturing defect resulting in a form of programmed polyethylene failure.


Orthopaedic Proceedings
Vol. 90-B, Issue SUPP_II | Pages 320 - 320
1 Jul 2008
Muller S Deehan D Holland J Kirk L Outerside S Gregg P McCaskie A
Full Access

We report the results of a prospective randomised controlled clinical trial assessing the radiosterophotogrametric analysis (RSA), clinical and radiological performance of a metal backed and an all-polyethylene tibial cruciate retaining, condylar design, PFC-TKA up to twenty four months.

65 patients were recruited, of which 41 patients were randomised. There were 20 metal backed and 21 all-polyethylene. None were lost to follow-up. There were no significant inter-group demographic differences. We found a significant increase in SF-12 and Oxford knee scores after surgery in both groups. No significant difference was found between the groups in the RSA, SF-12, Oxford Knee score, radiological alignment and range of movement at 6, 12 or 24 months. At 2 years one metal backed implant showed translational migration > 1mm. No all polyethylene implant migrated > 1mm. Further analysis identified possible progressive subsidence of the metal backed implants compared to all-polyethylene implants, although the magnitude of this difference was very small.

We conclude that in the uncomplicated primary total knee arthroplasty, all polyethylene PFC-_ tibial prostheses had equivalent performance to the metal backed counterpart, using RSA as the primary assessment instrument at 24 months. We found no differences between the two designs as assessed by the secondary instruments: SF-12, Oxford knee score, alignment and range of movement at 24 months. Should half of all primary total knee replacements performed in the UK receive an all-polyethylene tibial implant, the estimated annual cost saving would be 21 million pounds per annum.


Orthopaedic Proceedings
Vol. 88-B, Issue SUPP_III | Pages 370 - 370
1 Oct 2006
Loughead J Chesney D Holland J McCaskie A
Full Access

Introduction: Patients following resurfacing frequently remark about the natural feel of the resurfaced hip joint in contrast to those with total hip arthroplasty. Possible reasons for this include the larger femoral head size, conservation of bone and superior biomechanics of the implant with more accurate restoration of femoral offset, leg length and femoral anteversion.

Our aim was to assess femoral offset and leg length following hip resurfacing and hybrid THR (uncemented acetabulum) performed by the same surgeon.

Methods: A consecutive group of patients were identified (35 resurfacing and 25 hybrid). AP pelvis radiographs were evalulated, films with evidence of malrotation or inadequate imaging of the femur were excluded, leaving 21 resurfacing and 15 hybrid. Comparison was made between the pre-op and post-op films together with the contralateral hip on the same film. Patients with hip dysplasia or significant pathology in the contralateral hip were excluded. Magnification of the films was measured by comparison of the templated diameter of the implanted femoral head and the acutal diameter of the implant. To allow comparison between pre-op films a measurement was taken between the obturaror foraminae.

All films were analysed by the same investigator using the technique described by Jolles et al (J Arthroplasty 2002). A horizontal line was drawn between the base of the teardrop on both sides, and perpendicular lines drawn from the back of the teardrops. The anatomical femoral axis was drawn and femoral offset measured from this. The centre of rotation of the femoral head was determined by templating and the acetabular offset obtained.

Distance from tip of the greater trochanter to the centre of the femoral head in the axis of the femur was determined on pre and post-op films, as this shows little variation with rotation of the femur. Leg length was measured from the horizontal line to the tip of the greater trochanter together with the angle between the femoral axis and the horizontal to correct for abduction of the hip.

Results: Mean total femoral offset compared to the contralateral side was −1.3mm (SD 5.3) and −3.2mm (SD 6.5) for the resurfacing and hybrid groups respectively. No significant difference was detected in leg length or other measurements.

Discussion and Conclusion: No significant differences were demonstrated between femoral offset or leg length in the resurfacing and hybrid arthroplasty groups. This study does not support the hypothesis that resurfacing produces more accurate restoration of hip biomechanics than hybrid total hip arthroplasty.


Orthopaedic Proceedings
Vol. 86-B, Issue SUPP_III | Pages 279 - 279
1 Mar 2004
Munawar H Burton M Holland J
Full Access

Aims: To review the early results of Birmingham hip resurfacing (BHR). First 116 hips (98 patients). Materials: A cohort of consecutive patients prospectively underwent BHR in a single arthroplasty Surgeonñs practice in a University Hospital out side Birmingham. Inclusion criteria þt and active patients expected to out live conventional THR. 98 patients mean age 50 years (range 19–67). Pathology OA 85%, Perthes 7%, DDH 4.7% & SUFE 2%. Mean follow-up 30 months (range 12–45). Scoring systems used were Harris hip score (HHS), WOMAC & SF 36. Results: All patients under review, no radiological loosening.

HHS:Mean pre-arthroplasty score 47 (range 10–73), 1 yr score 99 (n=38), 2yr 97.3 (n=30) at 3yr 100 (n=26) & 4th yr 100 (n=4), this shows a statistically signiþcant improvement (P=0.001).

WOMAC: Pain: pre-op score 18.8, at 1 year 5.6 & 2nd year 5.7. Stiffness: pre-op 8.5, 1 year 2.7 & 2nd year 2.7. Physical: 49.3, 1 year 23.4 & 2nd year 22.6.

This shows a statistically signiþcant improvement in score (p=0.025) SF-36 Analysed against an age/sex match control group of normal values using a 2 tailed Ôtñ Test, seven of the eight domains showed no statistical signiþcant difference. Complications: One fracture following a fall, 2 AVN & early fractures (patients had deep cysts in proximal head now such patients are not offered BHR), one dislocation following RTA Conclusions: Birmingham hip resurfacing can provide excellent level of activity and patient satisfaction. Careful patient selection is needed. A long-term study is needed to evaluate the long-term beneþt and survivorship


Orthopaedic Proceedings
Vol. 85-B, Issue SUPP_II | Pages 158 - 158
1 Feb 2003
Hashmi M Burton M Holland J Reddy V
Full Access

To review the early functional results of Birmingham hip resurfacing. First 116 hips (98 patients), a cohort of consecutive patients prospectively underwent BHR in a single arthroplasty Surgeon’s practice in a University Hospital outside Birmingham. Inclusion criteria fit and active patients. 98 patients mean age 50 years (range 19–67). Pathology OA 85%, Perthes 7%, DDH 4.7% & SUFE 2%. Mean follow-up 30 months (range 12–45). Scoring systems used were Harris hip score (HHS), WOMAC & SF36.

HHS: mean pre-arthroplasty 47 (range 10–73), one year 99 (n=57), at 2 years 97.3 (n=26) and at third year 100 (n=3), statistically significant improvement (P=0.001).

WOMAC: pain: pre-op score 18.8, at 1 year 5.6 and second year 5.7. Stiffness: pre-op 8.5, 1 year 2.7 & 2nd year 2.7. Physical: 49.3, 1 year 23.4 & 2nd year 22.6.

This shows a statistically significant improvement in pain score (p=0.025) and physical function score (p=0.025).

SF-36 one-year post op, when analysed against an age/sex match control group normal values using a 2 tailed ‘t’ Test, seven of the eight domains showed no statistical significance. Only the Social Functioning domain showed a statistically significant result (p=0.011).

One fracture following a fall (patient had deep cysts in proximal head now such patients are not offered BHR), one dislocation following RTA and one AVN in a 50 years old post menopausal lady.

Birmingham hip resurfacing can provide excellent level of activity and patient satisfaction. A long-term study is needed to evaluate the long-term benefit and survivorship.


Orthopaedic Proceedings
Vol. 85-B, Issue SUPP_I | Pages 7 - 7
1 Jan 2003
Murray J Cooke N Rawlings D Holland J McCaskie A
Full Access

Dual Energy X-ray absorption (DEXA) has been used to measure bone mineral density (BMD) around total hip prostheses. With the recent increase in the use of metal on metal hip resurfacing, such as the Birmingham Hip Resurfacing (BHR), there has been renewed concern over per prosthetic femoral neck fracture and implant loosening. DEXA quantitatively measures bone mineral density and therefore could predict impending loosening and fracture. To the best of our knowledge, there are no recorded studies assessing BMD around metal-on-metal hip resurfacings such as the BHR. Our intention was to produce a reliable method of measuring bone density around a metal-on-metal hip resurfacing, such as the BHR, prior to a prospective study.

We performed DEXA scans on five patients (7 BHR’s), who had undergone resurfacing with the BHR within the last two years, using the Hologic QDR 45000A scanner. Each BHR was scanned twice on the same day with complete patient repositioning between scans. We analysed the data with the Hologic prosthetic hip (v 8.26a: 3) scan analysis software (operating software 9.80D) by identifying a variable number of same-sized regions of interest (ROI) within the femoral neck. These ROI’s were derived from an inter-trochanteric line and the axis of the BHR stem in the femoral neck. Each of the 14 scans was analysed twice, by three of the authors independently; with at least one week between repeat analysis by the same observer. Statistical analysis was carried out by the local University Department of Statistics.

The variation within the same ROI in a given BHR was 0.00353, whereas the variation between all ROI’s was 1.155. The intraclass-correlation was 0.997 (i.e. the correlation between any two assessments of one ROI) with an overall coefficient of variation of 5%. The variation between the two scans for each BHR and between the three assessors was not significant (p=0.87 and p=0.42 respectively). The mean BMD of the individual ROI’s, between the two assessments of the same scans by the same assessor (i.e. intra-observer variation) was lower on the second assessment by 0.0214gcm−2 (SD=0.0025) representing 0.5% mean density for all ROI’s. This difference was statistically significant (p< 0.001).

This method demonstrates excellent reproducibility of the method. Inter-scan and inter-observer variation was so negligible that a tiny intra-observer variation of 0.5% (of mean bone density) became statistically significant (p< 0.001), despite it making no difference to the overall intraclass-correlation. Statistical advice suggested that this very small difference in mean density (intra-observer) only reached significance due to the highly sensitive measurements and excellent reproducibility.

We have designed and demonstrated a safe, non-invasive and highly reproducible method for scanning BHR implants in vivo using DEXA. We will now use this method to prospectively study our BHR population to detect impending loosening or fracture.