header advert
Results 41 - 60 of 64
Results per page:
Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_20 | Pages 93 - 93
1 Nov 2016
Weeks C Somerville L Phillips J Ganapathy S Howard J
Full Access

The use of spinal anesthesia with adjuvant intra-thecal opioids has been commonly used in total knee arthroplasty without documented clinical benefit. It has been associated with a potential increase in side effects, including nausea, vomiting, pruritus, urinary retention and oxygen usage. This double-blinded RCT investigated whether the addition of epimorph to spinal anesthesia in patients undergoing total knee arthroplasty resulted in superior pain control and decreased narcotic consumption without also causing an increase in postoperative complication rates.

We performed a prospective double-blind trial in patients undergoing primary total knee arthroplasty (TKA). Patients were randomised to receive either spinal anesthesia alone or spinal anesthesia with epimorph (150 ug). All patients received infiltration of a local anesthetic cocktail intraoperatively. Both the study patients and staff measuring outcomes were blinded to the experimental treatment received during data collection. Postoperatively, visual analogue scale (VAS) for pain was recorded at 6, 12, 18, 24, 36 and 48hrs and a final value at 1 week. Narcotic use, Foley insertion, oxygen requirements, nausea, vomiting and pruritus were recorded during the course of hospitalisation.

Forty-one patients were randomised into each of the spinal with epimorph and spinal alone treatment arms. The groups showed no significant differences in BMI, age, and gender distribution. In the first 12 hours postoperatively there was no difference in VAS for pain between the two groups, however there were significantly lower pain scores in the spinal alone patients at 18 hours (p=0.002), 24 hours (p=0.04) and 48 hours (p = 0.03) compared to the spinal with epimorph group. Narcotic usage was greater in the spinal group during the first 6 hours postoperatively, but beyond this time point narcotic usage was similar between the two groups. Additionally, there was a statistically significant increase in rate of complications with spinal epimorph including nausea (p=0.037) and pruritus (p=0.024). The incidence of urinary retention was greater in the spinal epimorph group, however this did not reach statistical significance.

This study demonstrates no clinical benefit with the addition of intra-thecal opioids to spinal anesthetic in primary TKA. In addition to a failing to reduce VAS pain scores and overall narcotic consumption, increased complication rates were seen. For these reasons, this study does not support the use of epimorph in addition to spinal anesthesia for pain control in TKA.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_20 | Pages 57 - 57
1 Nov 2016
Lanting B Tan S Lau A Teeter M Del Balso C McCalden R MacDonald S Vasarhelyi E McAuley J Naudie D Howard J
Full Access

Trunnionosis in modular hip arthroplasty has recently been recognised to be clinically important. Gaining an understanding of how the material interface at the head-trunnion affects the tribology at the modular junctions has current clinical implications as well as an implication on future implant selection and material choice. This matched-cohort study aims to compare tribocorrosion between ceramic and cobalt-chromium trunnions and to investigate other factors that contribute to the difference in tribocorrosion if present.

All hip prostheses retrieved between 1999 and 2015 at one centre were reviewed. Fifty two ceramic heads were retrieved, and these were matched to a cobalt-chromium cohort according to taper design, head size, neck length and implantation time in that order. The two cohorts were similar in male:female ratio (p=0.32) and body mass index (p=0.15) though the ceramic group was younger than the cobalt-chromium group (56.6 (+/−)13.5 years for ceramic group vs 66.3 (+/−14.4) years for cobalt-chromium group; p=0.001). There was no significant difference in the reasons for revision between the two groups (p=0.42). The femoral head trunnions were examined by two independent observers using a previously published 4-point scoring technique. The trunnions were divided into three zones: apex, middle and base. The observers were blinded to clinical and manufacturing data where possible.

Ceramic head trunnions demonstrated a lower median fretting and corrosion score at the base zone (p<0.001), middle zone (p<0.001) and in the combined score (p<0.001). In a subgroup analysis by head size, ceramic heads had a lower fretting and corrosion score at 28mm head diameter (p<0.001). Within the ceramic group, taper design had a significant effect on fretting and corrosion in the apex zone (p=0.04). Taper design also had a similar effect in the cobalt-chromium group in the apex zone (p=0.03). For the ceramic trunnions, the largest effect was contributed by the difference between the 11/13 taper and the 12/14 taper. For the cobalt-chromium trunnions, the largest effect was contributed by the difference between the 5 degree 38′ 37″ taper and type 1 taper.

Ceramic head trunnions showed a significantly lower fretting and corrosion score as compared to cobalt-chromium trunnions. Ceramic heads had a lower score than cobalt-chromium heads at 28mm head diameter. Taper design had an effect on fretting and corrosion within each cohort.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_20 | Pages 5 - 5
1 Nov 2016
Teeter M Lam K Howard J Lanting B Yuan X
Full Access

Radiostereometric analysis (RSA) has become the gold standard technique for measuring implant migration and wear following joint replacement due to its high measurement precision and accuracy. However, RSA is conventionally performed using two oblique radiographic views with the presence of a calibration cage. Thus, a second set of radiographs must be acquired for clinical interpretation, for example anterior-posterior and cross-table lateral views following total hip arthroplasty (THA). We propose a modification to the RSA setup for examining THA, in which RSA measurements are performed from anterior-posterior and lateral views, with the calibration cage images acquired separately from the patient images. The objective of the current study was to compare the accuracy and precision of the novel technique to the conventional technique using a phantom.

X-ray cassette holders were developed to enable simultaneous acquisition of anterior-posterior and cross-table lateral radiographs with the patient in a supine position in the RSA suite. A Sawbones phantom with total hip implant components was attached to a micrometer-driven stage. The femoral component was translated known distances relative to the acetabular cup in all planes, mimicking head penetration due to wear. Double RSA examinations were acquired for each increment using the traditional and novel radiograph orientations. Translations were measured from the radiographic images using RSA software. For both techniques, accuracy was calculated by comparing the measured translations to the known translation from the micrometer, and reported as the 95% confidence interval. Precision was measured by comparing the measured translations between the double exams, and reported as the standard deviation.

Accuracy was greater for the conventional technique in the inferior-superior axis (p = 0.03), greater for the novel technique in the anterior-posterior axis (p = 0.01), and equivalent in the medial-lateral axis (p = 0.06). Overall accuracy for both the conventional and novel techniques was identical at ±0.022 mm. Precision was equivalent between both techniques for the medial-lateral (p = 0.68), inferior-superior (p = 0.14), and anterior-posterior axes (p = 0.86). Overall precision for the conventional technique was ±0.127 mm and for the novel technique was ±0.095 mm.

Utilising standard clinical radiograph view angles within an RSA exam had no detrimental effect on wear measurement accuracy or precision. This reduces the barriers to implementing RSA imaging in routine follow-up of arthroplasty patients, potentially greatly increasing the numbers of patients that can have quantitative data on implant performance. Future applications can involve applying more clinically relevant radiograph view angles to RSA exams of the knee and shoulder.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_20 | Pages 88 - 88
1 Nov 2016
Howard J Brenkel I Chang C Clatworthy M Hamilton W Howard J Huey V Kantor S Lesko J Nunley R Verdonk P
Full Access

With the introduction of new technology in orthopaedics, surgeons must balance anticipated benefits in patient outcomes with challenges or complications associated with surgical learning curve for the technology. The purpose of this study was to determine whether surgeon learning curve with a new multi-radius primary TKA system and instruments designed to improve surgical team ease would impact clinical outcomes, surgical time, and complications.

From November 2012 to July 2015, 2369 primary TKAs were prospectively enrolled in two multicentre studies across 50 sites in 14 countries with a new knee system (NEW-TKA) evenly balanced across four configurations: cruciate retaining or posterior stabilised with either fixed bearing or rotating platform (CRFB, CRRP, PSFB, PSRP). 2128 knees had a<1 year visit and 1189 had a minimum 1 year visit. These knees were compared to a reference dataset of 843 primary TKAs from three manufacturers in the same four configurations with currently available products (CA-TKA). Demographics for NEW-TKA and CA-TKA were similar and typical for primary TKA. Operative times, clinical outcomes and a series of five patient reported outcomes were compared for NEW-TKA vs. CA-TKA. The first 10 New-TKA subjects for each surgeon were defined as learning curve cases (N=520) and were compared to all later subjects (N=1849). Patient reported outcome measure and clinical outcome analyses were covariate adjusted for patient demographics, pre-op assessment and days post-op.

Mean (SD) surgical time for NEW-TKA learning curve cases was 79.1 (24.3) minutes, which reduced thereafter to 73.6 (24.3) (p=0.002). Beyond 10 cases, there was a continued reduction in NEW-TKA surgical time (R-Squared = 0.031). After 10 cases, surgical time was on par with the mean (SD) 71.9 (21.6) for CA-TKA (p=0.078). PROM outcomes of the first 10 learning curve cases for NEW-TKA were not statistically different from later cases at less than 1 year or later when adjusted for relevant covariates including configuration, patient demographics, pre-op functional status, and time post-op (p-values > 0.01). PROM outcomes for NEW-TKA vs. CA-TKA under the same covariate adjustments showed a trend favoring KOOS ADL, Symptoms, and Sport and Recreation subscores at minimum 1 year (p-values < 0.01). The incidence of intraoperative operative site complications was 1.3% for the NEW-TKA learning curve cases which was similar to the 0.6% rate for historical CA-TKA (p=0.231) and the intraoperative complication rate for the NEW-TKA later cases was consistent with learning curve cases (p=0.158).

The introduction of new implants into the market place needs to have adequate data to support that they are safe and effective. Except for a minor increase in surgical time during the first 10 patients, this study found that surgeon learning curve with this new primary TKA system does not adversely affect patient short term outcomes and complication rates.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_20 | Pages 62 - 62
1 Nov 2016
MacLean C Vasarhelyi E Lanting B Naudie D Somerville L McCalden R McAuley J MacDonald S Howard J Yuan X Teeter M
Full Access

The advent of highly cross-linked polyethylene has resulted in improved wear rates and reduced osteolysis with at least intermediate follow-up when compared to conventional polyethylene. However, the role of alternative femoral head bearing materials in decreasing wear is less clear. The purpose of this study was to determine in-vivo polyethylene wear rates across ceramic, Oxinium, and cobalt chrome femoral head articulations.

A review of our institutional database was performed to identify patients who underwent a total hip arthroplasty using either ceramic or oxidised zirconium (Oxinium) femoral head components on highly cross-linked polyethylene between 2008 and 2011. These patients were then matched on implant type, age, sex and BMI with patients who had a cobalt chrome bearing implant during the same time period. RSA analysis was performed using the centre index method to measure femoral head penetration (polyethylene wear). Secondary quality of life outcomes were collected using WOMAC and HHS Scores. Paired analyses were performed to detect differences in wear rate (mm/year) between the cobalt chrome cohorts and their matched ceramic and Oxinium cohorts. Additional independent group comparisons were performed by analysis of variance with the control groups collapsed to determine wear rate differences between all three cohorts.

A total of 68 patients underwent RSA analysis. Fifteen patients with a ceramic femoral head component and 14 patients with an Oxinium femoral head component along with the same number of matched patients with cobalt chrome femoral head component were included in the analysis. The time in vivo for the Oxinium (5.17 +/− 0.96 years), Oxinium matched cohort (5.13 +/− 0.72 years), ceramic (5.15 +/− 0.76 years) and ceramic matched cohort (5.36 +/− 0.63 years) were comparable. The demographics of all bearing surface cohorts were similar. The paired comparison between the Oxinium and cobalt chrome cohorts (0.33 vs. 0.29 mm/year, p=0.284) and ceramic vs cobalt chrome cohorts (0.26 vs. 0.20 mm/year, p=0.137) did not demonstrate a significant difference in wear rate. The independent groups analysis revealed a significantly higher wear rate of Oxinium (0.33 mm/year) compared to cobalt chrome (0.24 mm/year) (p = 0. 038). There were no differences in HHS and WOMAC scores between the Oxinium and cobalt chrome cohorts (HHS: p = 0.71, WOMAC: p=0.08) or the ceramic and cobalt chrome cohorts (HHS: p=0.15, WOMAC: p=023).

This study presents evidence of a greater wear rate (mm/year) of the Oxinium femoral head component compared to a cobalt chrome femoral head component. This difference was not demonstrated in the ceramic femoral head component. Despite this difference, there were no clinical differences as measured by the HHS and WOMAC. Future research should focus on factors that may contribute to the higher wear rate seen in the Oxinium cohort.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_20 | Pages 100 - 100
1 Nov 2016
Petis S Vasarhelyi E Lanting B Jones I Birmingham T Howard J
Full Access

Total hip arthroplasty (THA) is the most effective treatment modality for severe arthritis of the hip. Patients report excellent clinical and functional outcomes following THA, including subjective improvement in gait mechanics. However, few studies in the literature have outlined the impact of surgical approach on gait kinetics and kinematics. The purpose of this study was to determine the impact of surgical approach for THA on quantitative gait analysis.

Thirty patients undergoing THA for primary osteoarthritis of the hip were assigned to one of three surgical approaches (10 anterior, 10 posterior, and 10 lateral). A single surgeon performed each individual approach. Each patient received standardised implants at the time of surgery (cementless stem and acetabular component, cobalt chrome femoral head, highly cross-linked liner). Patients underwent 3D gait analysis pre-operatively, and at 6- and 12-weeks following the procedure. At each time point, temporal gait parameters, kinetics, and kinematics were compared. Statistical analysis was performed using one-way analysis of variance.

All three groups were similar with respect to age (p=0.27), body mass index (p=0.16), and the Charlson Comorbidity Index (p=0.66). Temporal parameters including step length, stride length, gait velocity, and percent stance and swing phase were similar between the groups at all time points. The lateral cohort had higher pelvic tilt during stance on the affected leg than the anterior cohort at 6-weeks (p=0.033). Affected leg ipsilateral trunk lean during stance was higher in the lateral group at 6-weeks (p=0.006) and 12-weeks (p=0.037) compared to the other cohorts. The anterior and posterior groups demonstrated an increased external rotation moment at 6-weeks (p=0.001) and 12-weeks (p=0.005) compared to the lateral group.

Although temporal parameters were similar across all groups, some differences in gait kinematics and kinetics exist following THA using different surgical approaches. However, the clinical relevance based on the small magnitude of the differences remains in question.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_20 | Pages 103 - 103
1 Nov 2016
Yao R Lanting B Howard J
Full Access

The direct anterior (DA) approach for total hip arthroplasty (THA) has become increasingly popular in North America. With experience, exposure of both the acetabulum and femur can be achieved similar to those in other approaches. In cases of difficult femoral exposure, the conjoint tendon of the short external rotators can be released to improve visualisation. The effect of conjoint tendon release has not been previously explored in regards to overall outcomes, or postoperative pain. The goal of this study was to evaluate 1) the length of stay and inpatient pain medication requirements of patients undergoing DA THA on the basis of conjoint tendon release, and 2) whether conjoint tendon release influenced functional outcomes.

We conducted a retrospective chart review of all cases of primary DA THAs conducted by single surgeon at LHSC University between August 2012 and July 2015. Patient demographics, bilateral THA cases, intraoperative conjoint tendon or other soft tissue releases, intra-operative complications, and length of stay (LOS) were evaluated for all cases. Inpatient pain medication data was available for all cases from Apr 2014 onwards. One year functional outcome scores, including WOMAC and Harris Hip Scores (HHS), were evaluated for all cases before August 2014. Six-week and three-month functional outcome scores were available and evaluated for a subset of cases. All data was analysed with multiple linear regression.

Three hundred and twelve cases of primary DA THAs were identified, of which 29 were concurrent bilateral THAs. One hundred and eighty cases included a conjoint tendon release, while 29 cases had other soft tissue releases (tensor fascia lata). Mean age and BMI were 64.9±11.5 years and 29.0±5.3 respectively. Mean LOS was 1.3±1.1 days, with age, bilateral THA, non-conjoint tendon soft tissue release, and intra-operative complications being predictive of LOS (p<0.05). Pain medication data was available for 107 cases, of which 11 were concurrent bilateral THAs. Sixty four cases included a conjoint tendon release, while one case had other soft tissue releases. Mean daily morphine equivalent dose (MED) narcotic use was 43.2±48.2mg, with age being a negative predictor of narcotic use (p<0.05). BMI was a negative predictor of one year HHS pain, HHS total, and all WOMAC subcategory scores, while age was a negative predictor of one year HHS function and HHS total scores (p<0.05). None of the variables were predictive of six-week and three-month functional outcome scores. Conjoint tendon release was not predictive of LOS, inpatient pain medication requirements, or outcome scores.

Conjoint tendon release did not affect postoperative pain, LOS, or functional outcomes. Given that conjoint release improves femoral exposure, intraoperative thresholds for conjoint release should be low. The effect of intraoperative release of other soft tissues is uncertain, as this increased LOS but not postoperative pain.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_20 | Pages 58 - 58
1 Nov 2016
Neely S Berta D Ralley F Lanting B Vasarhelyi E McAuley J McCalden R MacDonald S Naudie D Howard J
Full Access

Total joint arthroplasty is commonly associated with post-operative anemia. Blood conservation programs have been developed to optimise patients prior to surgery. Epoetin Alfa (Eprex) or intravenous (IV) iron transfusions are two modalities that can be used pre-operatively to optimise hemoglobin and ferritin levels. There are, however, potential complications and increased costs associated with their use. Oral iron is a less costly option for those undergoing surgery but requires more time to take effect. There are no studies to date that examine the effects of an early screening program utilising oral iron supplementation prior to total joint arthroplasty. The purpose of this study is to evaluate the effect of implementing early pre-operative oral iron supplementation on patients prior total joint arthroplasty.

A retrospective review of patients undergoing total joint arthroplasty was performed using our institution clinical informatics database. We identified all patients seen in pre-admission clinic (PAC) between Jan 1, 2009 and March 31, 2010 representing our control group. We then identified all patients seen in PAC between October 1, 2012 and December 31, 2013. Patients in this cohort received screening blood work when booked for surgery, and oral iron supplementation was given to patients with hemoglobin of less than 135g/L or ferritin less than 100ug/L, thus representing our treatment group. Patients undergoing revision, uni-compartment knee arthroplasty and bilateral arthroplasties were excluded from the study. Pearson Chi-Square tests were used to calculate significance between groups with main outcomes including pre-admission hemoglobin, and pre-operative requirements for Eprex or IV iron.

In our control group, we identified 354 patients (25.6%) with hemoglobin less than 130 g/L at time of pre-admission clinic. In our treatment group, this number dropped significantly to only 16.4% of patients (p<0.005).

Implementation of an early screening program using oral iron supplementation resulted in a decrease in the number of patients with hemoglobin lower than 130 g/L at the time of pre-admission clinic. There was also a significant decrease in the use of Eprex and IV iron pre-operatively in the patients in the early screening program. These results encourage the use of early oral iron supplementation for patients with hemoglobin less than 135 g/L or ferritin less than 100ug/L in order to optimise patients prior to total joint arthroplasty.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_20 | Pages 63 - 63
1 Nov 2016
Akindolire J Marsh J Howard J Lanting B Somerville L Vasarhelyi E
Full Access

Total hip arthroplasty (THA) has become one of the most commonly performed elective procedures. Today, there are nearly 50 000 annual hospitalisations for hip replacement surgery in Canada. This number is projected to increase significantly with the aging population. Periprosthetic joint infection (PJI) is the 3rd leading cause of failure following THA and is reported to occur at an incidence of 1–3%. A two-stage re-vision THA is the current gold standard treatment and this has a tremendous economic impact on the healthcare system. The purpose of this study is to create an accurate cost estimate of two-stage revision THA and, in turn, evaluate the economic burden of PJI as it compares to primary THA in a Canadian healthcare context.

We conducted a retrospective review of primary THA cases and two-stage revision THA for PJI at our institution. Patients were matched for age and BMI. We recorded all costs associated with each procedure, including: OR time, equipment, length of hospital stay, readmission rates, and any other inpatient resource use. Unit costs were obtained using administrative data from the case costing department at London Health Sciences Centre. Billing fees associated with the procedure were obtained from the Ontario Schedule of Benefits. Descriptive statistics were used to summarise the demographic characteristics of patients, hospital costs and resource use data. Patients with PJI were compared to the matched cohort of primary THA using the t-test (for continuous variables), and the chi-square test (for categorical variables).

Twenty consecutive cases of revision THA were matched to 20 patients who underwent uncomplicated primary THA between 2006 and 2014. Periprosthetic infection was associated with a significant increase in hospital stay (26.5 vs. 2.0; p<0.001), clinic visits (9.5 vs. 3.8; p<0.001), readmission rates (12 vs. 1; p<0.001) and overall cost ($39 953 vs. $7 460; p<0.001) in comparison to the primary arthroplasty cohort.

Two-stage revision for infected THA is a significant economic burden to the healthcare system. Our data suggests a 5-fold increase in healthcare cost when compared to primary THA. This may be an important consideration when distributing resources among Canadian tertiary care centres.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_10 | Pages 104 - 104
1 May 2016
Petis S Howard J Lanting B Marsh J Vasarhelyi E
Full Access

Introduction

Total hip arthroplasty (THA) is a commonly performed surgical procedure for the treatment of hip arthritis. Approximately 50,000 THAs are performed annually in Canada. The costs incurred to the healthcare system are tremendous, amounting to anywhere between 4.3 and 7.3 billion dollars each year. Despite the substantial financial burden of THA to the Canadian healthcare system, few studies have provided accurate cost estimations of this procedure.

Purpose

To determine the impact of surgical approach on costs of THA from a hospital perspective, and provide an updated cost estimation of THA within a publically funded healthcare system.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_1 | Pages 13 - 13
1 Jan 2016
Al-Khateeb H Howard J Naudie D McCalden RW MacDonald S
Full Access

Introduction

Total knee arthroplasty (TKA) has proven clinical success with reported longterm survivorship of 92% in the elderly population. Concerns regarding increased loosening rates and potential need for multiple revision surgeries in patients younger than 60 years have traditionally discouraged TKA in younger patients. The purpose of this study was to review the longterm clinical and radiographic results of patients under the age of 45 yrs who underwent a total knee replacement.

Materials and Methods

A retrospective review of our institutional database was performed between January 1996 and December 2004 The criteria for inclusion in the study were as follows: age 45 years or younger at index arthroplasty, cemented condylar prosthesis, and a minimum follow-up of 9 years. A total of 39 consecutive primary cemented condylar knee arthroplasties in patients with end stage arthritis were performed in 36 patients who were 45 years or younger. The median length of followup was 13.6 years. There were 18 men and 21 women. The mean age was 40.6 years (range, 28–44). There were 23 right, 16 left, and 3 bilateral procedures. The mean body mass index was 31.2 kg/m2

Clinical and radiological evaluations were performed before surgery and at 6 weeks, 3 months, 1 year and every 2 years subsequently. Knee scores were calculated using the Knee Society Clinical Rating Scores (KSCRS), SF-12 and WOMAC scores to assess pre, and post-operative function. Postoperative anteroposterior and lateral views were assessed for femoral and tibial component position, alignment, and presence or progression of radiolucent lines at the bone-cement and prosthesis-cement interfaces

Statistical analysis was performed using the 2-sample test or Wilcoxon rank sum test for comparison of continuous variables. Kaplan-Meier analysis of implant survival was performed with failure defined as femoral component revision due to any cause.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_4 | Pages 92 - 92
1 Jan 2016
Vandekerckhove P Teeter M Naudie D Howard J MacDonald S Lanting B
Full Access

Summary

The effect of polyethylene wear and lift-off between the tibial and femoral components on the mechanical axis was assessed in primary TKA (Total Knee Arthroplasty) based on retrieval data and full leg radiographs.

Introduction

Controversy exist regarding performing a TKA with component placement in physiologic versus neutral alignment. Some literature indicates good survivorship and superior clinical outcome in undercorrected TKA's for varus osteoarthritic knees. However, other literature indicates decreased survivorship and coronal plane alignment is still one of the contributing factors to wear in total knee arthroplasty (TKA). The two determinants of the intra-articular deformity in TKA arepolyethylene wear and lift-off between the tibial and femoral compartment. The goal of this study was to evaluate the impact of wear and lift-off on the mechanical axis in neutral and varus aligned TKA's.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_4 | Pages 94 - 94
1 Jan 2016
Teeter M Lanting B Vasarhelyi E Ivanov T Vandekerckhove P Howard J Naudie D
Full Access

Increased modularity of total hip arthroplasty components has occurred, with theoretical advantages and disadvantages. Recent literature indicates the potential for elevated revision rates of modular neck systems and the potential for metallosis and ALVAL (Aseptic Lymphocyte dominated Vasculitis Associated Lesion) formation at the modular neck/stem site. Retrieval analysis of one modular neck implant design including SEM (Scanning Electron Microscopy) assessment was done and correlated to FEA (Finite Element Analysis) as well as clinical features of patient demographics, implant and laboratory analysis. Correlation of the consistent corrosion locations to FEA indicates that the material and design features of this system may result in a biomechanical reason for failure. The stem aspect of the modular neck/stem junction may be at particular risk.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_4 | Pages 96 - 96
1 Jan 2016
Vasarhelyi E Vijayashankar RS Lanting B Howard J Armstrong K Ganapathy S
Full Access

Introduction

Fast track arthroplasty regimens require preservation of motor power to perform early rehabilitation and ensure early discharge (1). Commonly performed nerve blocks like femoral and Sciatic nerve blocks results in motor weakness thereby interfering with early rehabilitation and may also predispose to patient falls (2, 3). Hence, targeting the terminal branches of the femoral and sciatic nerves around the knee joint under ultrasound is an attractive strategy. The nerve supply of interest for knee analgesia are the terminal branches of the femoral nerve, the genicular branches of the lateral cutaneous nerve of thigh, obturator and sciatic nerves (4).

Methods

We modified the performance of the adductor canal block and combined it with US guided posterior pericapsular injection and lateral femoral cutaneous nerve block to provide analgesia around the knee joint. The femoral artery is first traced under the sartorius muscle until the origin of descending geniculate artery and the block is performed proximal to its origin. A needle is inserted in-plane between the Sartorius and rectus femoris above the fascia lata and 5 ml of 0.5% ropivacaine (LA) is injected to block the intermediate cutaneous nerve of thigh. The needle is then redirected to enter the fascia of Sartorius to deliver an additional 5ml of LA to cover the medial cutaneous nerve of thigh following which it is further advanced till the needle tip is seen to lie adjacent to the femoral artery under the Sartorius to perform the adductor canal block with an additional 15–20 ml of LA to cover nerve to vastus medialis, saphenous nerve and posterior division of the obturator nerve (Fig 1). The lateral cutaneous nerve of thigh is optionally blocked with 10 ml of LA near the anterior superior iliac spine between the origin of Sartorius and tensor fascia lata (Fig 2). The terminal branches of sciatic nerve to the knee joint is blocked by depositing 25 ml of local anesthetic solution between the popliteal artery and femur bone at the level of femoral epicondyles (Fig 3).


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_4 | Pages 93 - 93
1 Jan 2016
Vandekerckhove P Teeter M Naudie D Howard J MacDonald S Lanting B
Full Access

Introduction

Coronal plane alignment is one of the contributing factors to polyethylene wear in total knee arthroplasty (TKA). The goal of this study was to evaluate the wear and damage patterns of retrieved tibial polyethylene inserts in relationship to the overall mechanical alignment and to the position of the tibial component.

Materials and methods

Based on full-length radiographs, ninety-five polyethylene inserts retrieved from primary TKA's with a minimum time in-vivo of five years were analysed for wear and damage. Four alignment groups were compared: valgus, neutral, mild varus and moderate varus. Varus and valgus positioning of the tibial component was analysed for damage score for the neutral and varus aligned groups.


Orthopaedic Proceedings
Vol. 97-B, Issue SUPP_16 | Pages 67 - 67
1 Dec 2015
Puzzolante C Warren S Zona S Howard J Palanivel S Mack D
Full Access

Beadmill processing combined with automated blood culture bottle methods (BACTEC™) has a greater sensitivity and specificity, and a shorter time to positivity compared with primary plates (PP) for prosthetic joint infection (PJI) diagnosis but the clinical impact of Bactec on antimicrobial therapy has not yet been evaluated. We compared time-to-positivity of Columbia agar with horse blood plates (BA) and chocolatized horse blood plates (CHOC) versus anaerobic (ANA) and aerobic blood culture bottles (02) in patients with PJI. We compared the contributions of the two methods to the commencement of effective and targeted antimicrobial therapy.

Retrospective observational study from June 2013 to March 2014. Inclusion criteria were confirmed PJI (IDSA criteria) with at least 2 perioperative samples. After beadmill processing BA and CHOC plates were incubated for 2 days and discarded if negative, BactecTM bottles were incubated for 14 days and sub-cultured if positive. MALDI-TOF (Microflex, Brucker) was used for identification and all isolates had sensitivities performed (Phoenix, BD). Standard empirical antibiotic treatment was teicoplanin, piperacillin/tazobactam and amikacin. We defined time to switch as difference between date of sample collection and date of commencing targeted or effective therapy; prior antibiotic therapy was defined as the use of antibiotics within 14 days before samples collection.

Fifty cases were identified during the study period. 330 microbiological isolates were included: 24 (7.3%) were considered contaminants; 153 isolates (50.0%) were detected both from BactecTM and PP; 152 (49.7%) from BactecTM only; 1 isolate (0.3%) from PP only. 17 (34%) diagnoses of PJI was made exclusively by BactecTM. The majority of isolates on BA and CHOC plates grew in the first 24 hours (81.2% and 77.5% respectively). 293/305 isolates from BactecTM (96.1%) grew in the first 2 days. Antibiograms were available after 2.5 days from PP versus 4 days from BACTEC (p<0.0001). When we compared time to switch from empiric to targeted therapy, no difference was seen between patients with positive BACTEC cultures only (median 4 days, range 2–15) versus patients with positive PP cultures, (median 5 days, range 2–9) (p=0.984). Where organisms were resistant to empirical therapy, PP results did not contribute to switching to effective therapy. Prior antibiotic therapy had no impact on time-to-positivity for both methods (R=−0.005, p=0.936).

Compared to BACTEC cultures for the diagnosis of PJIs, primary plate cultures did not provide additional diagnostic information and did not significantly reduce the time to effective or targeted antimicrobial therapy.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVIII | Pages 115 - 115
1 Sep 2012
MacDonald SJ Somerville L Howard J Naudie DD McAuley J McCalden R Bourne R
Full Access

Purpose

The pros and cons of general anesthesia versus spinal anesthesia in total hip arthroplasty has been a long debated topic. The purpose of this study was to compare the surgical times, blood loss and transfusion requirements between anesthetic types in patients undergoing primary total hip arthroplasty.

Method

A consecutive series of 1600 THA procedures with complete preoperative and postoperative data were evaluated. Twenty eight percent of procedures were performed with a general anesthetic (GA), 67% with a spinal anesthetic (SP) and 5% with a combination of the two. Outcomes were compared and tested for significance using the Independent Samples Kruskal Wallis or Pearson Chi-Square analysis.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVIII | Pages 27 - 27
1 Sep 2012
McAuley JP Lyons M Howard J McCalden R Naudie DD Bourne RB MacDonald SJ
Full Access

Purpose

The patella provides a mechanical advantage to the knee extensor mechanism. Patellectomy, performed for trauma or patellofemoral arthrosis, does not preclude the development of tibiofemoral arthrosis. Total knee arthroplasty is the mainstay of treatment for tibiofemoral arthrosis. The purpose of this study was to evaluate the outcomes of total knee arthoplasty in patients who previously underwent patellectomy.

Method

A retrospective analysis was completed on a prospectively collected database to identify all patients who underwent total knee arthroplasty following a previous patellectomy. Sixty-one total knee arthroplasties in 57 patients were identified. Patient demographics as well as functional outcome scores, including WOMAC and Knee Society Scores, were evaluated.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXVII | Pages 14 - 14
1 Jun 2012
El-Hawary R Howard J Cowan K Sturm P d'Amato C
Full Access

Introduction

Spinopelvic parameters describe the orientation, shape, and morphology of the spine and pelvis. These parameters change during the first 10 years of life in children without spinal deformity; however, spinopelvic parameters have yet to be defined in children with significant early-onset scoliosis (EOS). Sagittal plane alignment could affect the natural history and outcome of interventions for EOS. As a result, spinopelvic parameters are being defined for this population. On the basis of the landmarks used for measurement of these parameters, there may be inherent error in performing these measurements on the immature pelvis. The purpose of this study is to define the variability associatedwith the measurement of spinopelvic parameters in children with EOS.

Methods

Standing, lateral radiographs of 11 patients with untreated EOS were evaluated. Sagittal spinopelvic parameters (pelvic incidence [PI], pelvic tilt [PT], sacral slope [SS], and modified pelvic radius angle [PR]) were measured. To assess intraobserver reliability, these measurements were repeated 15 days apart. To define interobserver reliability, radiographs were measured by 2 independent observers.


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_I | Pages 22 - 23
1 Mar 2010
Malta L Ronsky J Howard J Komisar V Sauve B Evison R Parsons D
Full Access

Purpose: Torso surface topography has reliably detected scoliosis severity. A quantification of torso shape patterns associated with healthy spines is important as a basis for scoliosis screening, monitoring progression, and evaluating treatment methods. The study objective was to examine differences in torso surface geometry associated with age and gender in healthy children.

Method: Seventy normal healthy adolescents were recruited into 3 age groups (8–11, 12–14, 15–18 years), with a goal of equal representation across groups. All consenting subjects met inclusion criterion of no history of back or neuromotor problems, and BMI ≤ 30. Torso surface topography was obtained with Inspeck optical digitizers (InSpeck Ltd., Montreal, PQ) using standard clinical protocols. Subject arm span, height, weight and activity level was recorded. Subjects stood within a positioning frame, while five scans (5s/scan) were acquired. Three-dimensional models of each torso scan were generated. Torso shape was quantified with indices based on established spine-torso shape relations in scoliosis patients. Statistical analyses (p=0.05) were performed for 4 indices: principal axis of orientation, back surface rotation (BSR), rib prominence and quarter area at S1; L3, T12& T7vertebral levels.

Results: Two groups based on gender resulted in similar age distributions with males (Group 1, n = 31) having mean age of 12.76 ± 0.07 years; and females (Group 2, n=39) having mean age 12.64±0.17 years. No statistically significant differences in torso indices were found between the entire female and male groups. When stratified by group, significant differences were obtained between the youngest male group (8–11, n=9) and both the youngest (8–11, n=8) and middle (12–14, n=18) aged females. The quarter surface areas at T7 for the youngest males were statistically significantly different from females of similar age (p=0.036), and from the next older age group (p=0.025). The BSR (p=0.033) and rib prominence (p=0.038) at the L3 level were also significantly different between the youngest males and middle aged females.

Conclusion: General torso shape indice curves can be developed for healthy children, based on a combined database of males and females. However, differences in several torso indices are present between the youngest males and the same and middle age group females.