header advert
Results 21 - 40 of 95
Results per page:
The Bone & Joint Journal
Vol. 98-B, Issue 9 | Pages 1175 - 1179
1 Sep 2016
Olsen M Lewis PM Morrison Z McKee MD Waddell JP Schemitsch EH

Aims

One method of femoral head preservation following avascular necrosis (AVN) is core decompression and insertion of a tantalum rod. However, there may be a high failure rate associated with this procedure. The purpose of this study was to document the clinical and radiological outcomes following total hip arthroplasty (THA) subsequent to failed tantalum rod insertion.

Patients and Methods

A total of 37 failed tantalum rods requiring total hip arthroplasty were identified from a prospective database. There were 21 hips in 21 patients (12 men and nine women, mean age 37 years, 18 to 53) meeting minimum two year clinical and radiographic follow-up whose THAs were carried out between November 2002 and April 2013 (mean time between tantalum rod implantation and conversion to a THA was 26 months, 6 to 72). These were matched by age and gender to individuals (12 men, nine women, mean age 40 years, 18 to 58) receiving THA for AVN without prior tantalum rod insertion.


The Bone & Joint Journal
Vol. 95-B, Issue 4 | Pages 517 - 522
1 Apr 2013
Henry PDG Dwyer T McKee MD Schemitsch EH

Latissimus dorsi tendon transfer (LDTT) is technically challenging. In order to clarify the local structural anatomy, we undertook a morphometric study using six complete cadavers (12 shoulders). Measurements were made from the tendon to the nearby neurovascular structures with the arm in two positions: flexed and internally rotated, and adducted in neutral rotation. The tendon was then transferred and measurements were taken from the edge of the tendon to a reference point on the humeral head in order to assess the effect of a novel two-stage release on the excursion of the tendon.

With the shoulder flexed and internally rotated, the mean distances between the superior tendon edge and the radial nerve, brachial artery, axillary nerve and posterior circumflex artery were 30 mm (26 to 34), 28 mm (17 to 39), 21 mm (12 to 28) and 15 mm (10 to 21), respectively. The mean distance between the inferior tendon edge and the radial nerve, brachial artery and profunda brachii artery was 18 mm (8 to 27), 22 mm (15 to 32) and 14 mm (7 to 21), respectively. Moving the arm to a neutral position reduced these distances. A mean of 15 mm (8 to 21) was gained from a standard soft-tissue release, and 32 mm (20 to 45) from an extensile release.

These figures help to define further the structural anatomy of this region and the potential for transfer of the latissimus dorsi tendon.

Cite this article: Bone Joint J 2013;95-B:517–22.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVIII | Pages 11 - 11
1 Sep 2012
Sheth U Simunovic N Klein G Fu F Einhorn T Schemitsch EH Ayeni O Bhandari M
Full Access

Purpose

The recent emergence of autologous blood concentrates, such as platelet rich plasma (PRP), as a treatment option for patients with orthopaedic injuries has led to an extensive debate about their clinical benefit. Our objective was to determine the effectiveness of autologous blood concentrates compared with control therapy in improving pain in patients with orthopaedic bone and soft tissue injuries.

Method

We conducted a systematic review of MEDLINE and EMBASE from 1996 and 1947, respectively, up to July 2010. Additional studies were identified by contacting experts, searching the bibliographies of the included studies as well as orthopaedic meeting archives. We included published and unpublished randomized controlled trials or prospective cohort studies that compared autologous blood concentrates with a control therapy in patients with an orthopaedic injury. Two reviewers, working in duplicate, abstracted data on study characteristics and protocol. Reviewers resolved disagreement by consensus.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVIII | Pages 43 - 43
1 Sep 2012
Olsen M Edwards M Sellan M Crookshank MC Bristow L Schemitsch EH
Full Access

Purpose

Computer navigation for hip resurfacing has been shown to reduce the incidence of technical error during femoral head preparation and provides increased accuracy compared to conventional instrumentation for insertion of the initial femoral guidewire. Limitations to the widespread use of navigation in hip resurfacing include access and cost. A novel, patient specific nylon jig has been developed as a cost effective alternative for placement of the initial guidewire. The purpose of this study was to compare the accuracy of femoral guidewire insertion between imageless navigation, conventional instrumentation and a new type of CT-based custom jig.

Method

Six pairs of cadaveric femora were used in the study. Each pair was divided randomly between a group utilizing firstly a conventional lateral pin jig (BHR, Smith & Nephew Inc.) followed by navigation (Vector Vision SR, BrainLAB) and a group utilizing a CT-based, patient specific custom jig (Visionaire, Smith & Nephew Inc.). A single surgeon inserted all guidewires. The planned guidewire position was approximately 10 degrees of relative valgus to the native neck-shaft angle in the coronal plane and neutral version in the sagittal plane. The same coronal alignment angle was used between paired femora. Femurs were positioned in a draped synthetic foam hip model prepared with a standard posterior approach. Guidewire insertion time and placement accuracy for each of the three alignment methods was assessed. Guidewire placement accuracy for coronal inclination and version was assessed by anteroposterior and lateral digital radiographs and was defined as the mean deviation from the planned alignment value.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVIII | Pages 70 - 70
1 Sep 2012
Schemitsch EH Investigators S Sanders DW
Full Access

Purpose

There is no clear definition of a critical sized defect of the tibia. We defined it as a fracture gap at least one centimeter in length and involving over 50% of the cortical diameter. We explored if the presence of a critical-sized defect predicted reoperation, and which other factors predict reoperation in patients with the critical defect. The patient based outcomes of these patients were compared to patients without a critical defect.

Method

Patients enrolled in the SPRINT trial with a critical sized defect were evaluated for secondary interventions to gain union. Other factors predicting the need for reoperation were studied. We also compared the patients with critical sized defects to the larger cohort of patients without a defect with respect to demographics, injury mechanism, fracture characteristics, and patient-based outcome.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVIII | Pages 72 - 72
1 Sep 2012
Schemitsch EH Investigators S Bhandari M
Full Access

Purpose

Our hypothesis was that closed tibia fractures treated with intramedullary nails are impacted by surgeon and center volumes.

Method

Data from 813 patients with closed tibia fractures were obtained from the SPRINT study. Using multiple regression, we examined the effect of center and surgeon volume (categorized as high, moderate, or low), and geographic differences by country (Canada, USA, and the Netherlands) on health-related quality-of-life and revision surgeries to gain union at one year. Our measures of quality-of-life were the Short-Form 36 Health Survey Questionnaire (SF-36 PCS) and the Short Musculoskeletal Function Assessment (SMFA).


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVIII | Pages 160 - 160
1 Sep 2012
Kuzyk PR Saccone M Sprague S Simunovic N Bhandari M Schemitsch EH
Full Access

Purpose

Cross-linking of polyethylene greatly reduces its wear rate in hip simulator studies. We conducted a systematic review and meta-analysis of randomized controlled trials comparing cross-linked to conventional polyethylene liners for total hip arthroplasty to determine if there is a clinical reduction of: 1) wear rates, 2) radiographic osteolysis, and 3) need for total hip revision.

Method

A systematic search of MEDLINE, EMBASE, and COCHRANE databases was conducted from inception to May 2010 for all trials involving the use of cross-linked polyethylene for total hip arthroplasty. Eligibility for inclusion in the review was: use of a random allocation of treatments; a treatment arm receiving cross-linked polyethylene and a treatment arm receiving conventional polyethylene for total hip arthroplasty; and use of radiographic wear as an outcome measure. Eligible studies were obtained and read in full by two co-authors who then independently applied the Checklist to Evaluate a Report of a Nonpharmacological Trial to each study. Pooled mean differences were calculated for the following continuous outcomes: bedding-in, linear wear rate, three dimensional linear wear rate, volumetric wear rate, and total linear wear. Pooled risk ratios were calculated for radiographic osteolysis and revision hip arthroplasty.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVIII | Pages 161 - 161
1 Sep 2012
Waddell JP Edwards M Lutz M Keast-Butler O Escott B Schemitsch EH
Full Access

Purpose

To review prospectively collected data on patients undergoing primary total hip arthroplasty utilizing two different cementless acetabular components.

Method

All patients undergoing primary total hip replacement surgery at our institution are entered prospectively into a database which includes history and physical examination, radiology, WOMAC and SF-36 scores. The patients are re-examined, re-x-rayed and re-scored at 3 months, 6 months and 1 year after surgery and yearly thereafter.

Using this database we are able to identify patients who have undergone total hip replacement using one of two geometric variants of the acetabular component. The first design is hemispherical and the second design has a peripheral rim expansion designed to increase initial press-fit stability.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVIII | Pages 165 - 165
1 Sep 2012
Powell JN Beaulé PE Antoniou J Bourne RB Schemitsch EH Vendittoli P Smith F Werle J Lavoie G Burnell C Belzile É Kim P Lavigne M Huk OL O'Connor G Smit A
Full Access

Purpose

The purpose of the study was to determine the rate of conversion from RSA to THR in a number of Canadian centers performing resurfacings

Method

Retrospective review was undertaken in 12 Canadian Centers to determine the rate of revision and reason for conversion from RSA to THR. Averages and cross-tabulation with Chi-Squared analysis was performed. kaplan Meier survivorship was calculated.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVIII | Pages 202 - 202
1 Sep 2012
Schemitsch EH Schemitsch L Veillette C McKee MD COTS COTS
Full Access

Purpose

There is increasing evidence that primary fixation of displaced mid-shaft fractures of the clavicle results in superior short-term outcomes when compared to traditional non-operative methods. However, the results from published studies are limited to relatively short-term (one year or less) follow-up. Accurate data of longer follow-up is important for a number of reasons, including patient prognostication, counseling and care, the design of future trials, and the economic analysis of treatment. The purpose of this paper was to examine the results of the two year follow up of patients enrolled in a previously published randomized clinical trial of operative versus non-operative treatment of displaced fractures of the clavicle.

Method

Using a comprehensive and standard assessment that included DASH (Disabilities of the Arm, Shoulder and Hand) and CSS (Constant Shoulder Scores) scores, we evaluated ninety-five patients of the original cohort of one hundred and thirty-two patients at two years following their injury.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVIII | Pages 163 - 163
1 Sep 2012
Kuzyk PR Sellan M Morison Z Waddell JP Schemitsch EH
Full Access

Purpose

Femoroacetabular impingement (FAI) may contribute to the development of early onset hip osteoarthritis (OA). A cam lesion (or pistol grip deformity) of the proximal femur reduces head-neck offset resulting in cam type FAI. The alpha angle is a radiographic measurement recommended for diagnosis of cam type FAI. The purpose of this study was to determine if patients that develop end stage hip OA prior to 55 years of age have radiographic evidence of cam type FAI.

Method

The anteroposterior (AP) pelvis and lateral hip radiographs of 244 patients (261 hips) who presented to our institution for hip arthroplasty or hip fracture fixation between 2006 and 2008 were retrospectively reviewed. Three cohorts were compared: 1) patients with end stage hip OA < 55 years old (N=76); 2) patients with end stage hip OA > 55 years old (N=84); 3) hip fracture patients > 65 years old without radiographic evidence of hip arthritis were used as controls (N=101). Patients with inflammatory arthritis, avascular necrosis and post-traumatic hip OA were excluded. Alpha angles were measured on the AP pelvis and lateral radiographs by three coauthors using ImageJ 1.43 software (National Institutes of Health, USA). For patients with end stage hip OA, AP alpha angles were measured on both the hip with OA and the contralateral hip. Lateral alpha angles were measured only on the hip with OA. For patients with hip fracture, AP alpha angles were measured on the non-fractured hip and lateral alpha angles were measured on the fractured hip. A one-way ANOVA with post hoc Tukeys HSD test was used to compare the AP and lateral alpha angles for the three cohorts.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVIII | Pages 2 - 2
1 Sep 2012
Li R Qamirani E Atesok K Nauth A Wang S Li C Schemitsch EH
Full Access

Purpose

Angiogenesis and osteogenesis are essential for bone growth, fracture repair, and bone remodeling. VEGF has an important role in bone repair by promoting angiogenesis and osteogenesis. In our previous study, endothelial progenitor cells (EPCs) promoted bone healing in a rat segmental bone defect as confirmed by radiological, histological and microCT evaluations (Atesok, Li, Schemitsch 2010); EPC treatment of fractures resulted in a significantly higher strength by biomechanical examination (Li, Schemitsch 2010). In addition, cell-based VEGF gene transfer has been effective in the treatment of segmental bone defects in a rabbit model (Li, Schemitsch et al 2009); Purpose of this study: Evaluation of VEGF gene expression after EPC local therapy for a rat segmental bone defect.

Method

Rat bone marrow-derived EPCs were isolated from the rat bone marrow by the Ficoll-paque gradient centrifuge technique. The EPCs were cultured for 7 to 10 days in endothelial cell growth medium with supplements (EGM-2-MV-SingleQuots, Clonetics). and collected for treatment of the rat segmental bone defect. EPCs were identified by immunocytochemistry staining with primary antibodies for CD34, CD133, FLK-1, and vWF. A total of fifty six rats were studied. A five millimeter segmental bone defect was created in the middle 1/3 of each femur followed by mini plate fixation. The treatment group received 1×106 EPCs locally at the bone defect and control animals received saline only. Seven control and seven EPC treated rats were included in each group at 1, 2, 3 and 10 weeks. Animals were sacrificed at the end of the treatment period, and specimens from the fracture gap area were collected and immediately frozen. Rat VEGF mRNA was measured by reverse transcriptase-polymerase chain reaction (RT-PCR) and quantified by VisionWorksLS. All measurements were performed in triplicate.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVIII | Pages 148 - 148
1 Sep 2012
McKee RC Whelan DB Schemitsch EH McKee MD
Full Access

Purpose

Displaced midshaft clavicular fractures are a common injury with a high occurrence rate in young, active individuals. Non-operative care has traditionally been the standard of care for such fractures, but more recent studies have suggested benefits following primary operative fixation. The purpose of this study was to review the literature on displaced midshaft clavicle fractures, identify randomized controlled trials of operative versus non-operative treatment, and pool the functional outcome and complication rates (including nonunion and symptomatic malunion), to arrive at summary estimates of these outcomes.

Method

A systematic review of the literature was performed to identify studies of randomized controlled trials comparing operative versus non-operative care for displaced midshaft clavicle fractures. Meeting abstracts were also searched and included in this study.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVIII | Pages 200 - 200
1 Sep 2012
Crookshank MC Edwards M Sellan M Whyne CM Schemitsch EH
Full Access

Purpose

Femoral shaft fractures are routinely treated using antegrade intramedullary nailing under fluoroscopic guidance. Malreduction is common and can be due to multiple factors. Correct entry point identification can help minimize malreduction and the risk of iatrogenic fracture. This study aims to compare landmark identification used to guide nail entry, the piriformis fossa (PF) and the trochanteric tip (T), via computer navigation and conventional fluoroscopy.

Method

The location of the PF and T were digitized under direct visualization with a three-dimensional scribe on ten, fresh-frozen cadaveric right femora (two male, eight female) by three fellowship trained orthopaedic surgeons. To estimate inter- and intraobserver reliability of the direct measurements, an intraclass correlation coefficient was calculated with a minimum of two weeks between measurements. Under navigation, each specimen was draped and antero-posterior (AP) and lateral radiographs of the proximal femur were taken with a c-arm and image intensifier. The c-arm was positioned in a neutral position (0 for AP, 90 for lateral) and rotated in 5 increments, yielding a range of acceptable images. Images, in increments of 5, within the AP range (with a neutral lateral) were loaded into a navigation system (Stryker, MI). A single surgeon digitized the T and PF directly based on conventional fluoroscopy, and again directed by navigation, yielding two measurements per entry point per specimen. This was repeated for the lateral range. Hierarchical linear modelling and a Wilcox rank test were used to determine differences in accuracy and precision, respectively, in the identification of PF and T using computer navigation vs. conventional fluoroscopy.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVIII | Pages 135 - 135
1 Sep 2012
Schemitsch EH Investigators S
Full Access

Purpose

The SPRINT trial randomized 1226 patients with tibial shaft fractures treated by intramedullary (IM) nailing to reamed versus unreamed groups. Using data from this trial, we completed a subgroup analysis of those patients who required two or more reoperations following the initial IM fracture stabilization.

Method

We identified 44 patients with tibial shaft fractures who required two or more reoperations following IM nailing. We considered those that were reamed vs unreamed, open vs closed, those that were planned for reoperation after the 12 month follow up, and the indications for reoperation.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVIII | Pages 107 - 107
1 Sep 2012
Waddell JP Nikolaou V Edwards M Bogoch E Schemitsch EH
Full Access

Purpose

This prospective randomised controlled trial aims to compare the clinical and radiological outcomes of ceramic on ceramic, cobalt chrome on ultra-high molecular weight polyethylene, and cobalt chrome on highly cross-linked polyethylene bearing surfaces at a minimum of five years.

Method

One hundred and two primary total hip replacements were performed in ninety one patients between February 2003 and March 2005. All patients were younger than 65 (mean 52.7, 19–64). They were randomised to receive one of the three bearing surfaces. All patients had 28mm articulations with a Reflection uncemented acetabular component and a Synergy stem (Smith & Nephew, Memphis, Tennessee). Patients were followed up periodically up to at least sixty months following surgery. Outcome measures included WOMAC and SF12 scores. Radiological assessment included implant position, evidence of osteolysis and measurement of linear wear.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVIII | Pages 114 - 114
1 Sep 2012
Olsen M Sellan M Zdero R Waddell JP Schemitsch EH
Full Access

Purpose

The Birmingham Mid-Head Resection (BMHR) is a bone-conserving, short-stem alternative to hip resurfacing for patients with compromised femoral head anatomy. It is unclear, however, if an uncemented, metaphyseal fixed stem confers a mechanical advantage to that of a traditional hip resurfacing in which the femoral prosthesis is cemented to the prepared femoral head. Thus, we aimed to determine if a metaphyseal fixed, bone preserving femoral component provided superior mechanical strength in resisting neck fracture compared to a conventional hip resurfacing arthroplasty.

Method

Sixteen matched pairs of human cadaveric femurs were divided evenly between specimens receiving a traditional epiphyseal fixed hip resurfacing arthroplasty (BHR) and those receiving a metaphyseal fixed BMHR. Pre-preparation scaled digital radiographs were taken of all specimens to determine anatomical parameters as well as planned stem-shaft angles and implant sizes. A minimum of 10 degrees of relative valgus alignment was planned for all implants and the planned stem-shaft angles and implant sizes were equal between femur pairs. Prior to preparation, bone mineral density scans of the femurs were obtained. Prepared specimens were potted, positioned in single-leg stance and tested to failure using a mechanical testing machine. Load-displacement curves were used to calculate construct stiffness, failure energy and ultimate failure load.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 4 | Pages 459 - 465
1 Apr 2012
Nikolaou VS Edwards MR Bogoch E Schemitsch EH Waddell JP

The ideal bearing surface for young patients undergoing total hip replacement (THR) remains controversial. We report the five-year results of a randomised controlled trial comparing the clinical and radiological outcomes of 102 THRs in 91 patients who were <  65 years of age. These patients were randomised to receive a cobalt–chrome on ultra-high-molecular-weight polyethylene, cobalt–chrome on highly cross-linked polyethylene, or a ceramic-on-ceramic bearing. In all, 97 hip replacements in 87 patients were available for review at five years. Two hips had been revised, one for infection and one for peri-prosthetic fracture.

At the final follow-up there were no significant differences between the groups for the mean Western Ontario and McMaster Universities osteoarthritis index (pain, p = 0.543; function, p = 0.10; stiffness, p = 0.99), Short Form-12 (physical component, p = 0.878; mental component, p = 0.818) or Harris hip scores (p = 0.22). Radiological outcomes revealed no significant wear in the ceramic group.

Comparison of standard and highly cross-linked polyethylene, however, revealed an almost threefold difference in the mean annual linear wear rates (0.151 mm/year versus 0.059 mm/year, respectively) (p < 0.001).


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_IV | Pages 561 - 561
1 Nov 2011
Walmsley DW Peskun C Waddell JP Schemitsch EH
Full Access

Purpose: There is growing support in the medical literature that patient outcomes are adversely affected by physician fatigue in operator-dependent cognitive and technical tasks. The recent increase in total joint arthroplasty case load has resulted in longer operative days and increased surgeon fatigue. The purpose of this study was to determine if time of day predicts perioperative outcomes and complications in total hip and knee arthroplasty surgery.

Method: The records of all primary Total Hip Arthroplasty (THA) and Total Knee Arthroplasty (TKA) surgery performed for primary osteoarthritis, during 2007 at one large university hospital, were retrospectively reviewed. Complete demographic data (age, gender, Body Mass Index), start time of surgery, intraoperative complications, duration of surgery, radiographic component alignment, and functional outcome scores (SF-12 and WOMAC) for 341 THA and 292 TKA patients were collected and analyzed using linear and nonparametric rank correlation statistics. Data was corrected for gender, body mass index (BMI), surgeon, and post-call operating days.

Results: In the THA cohort, a later start time of surgery was significantly related to duration of surgery (p=0.0013). In addition, there was a trend towards significance for intraoperative femur fracture (p=0.0542) later in the day. Postoperative complications, component alignment, and functional outcome scores were not significantly affected by start time of surgery. There were no significant findings for any of the intraoperative or postoperative outcomes in the TKA cohort.

Conclusion: This study demonstrates that duration of surgery and the incidence of intraoperative complications for THA may increase as the start time of surgery becomes later in the day. These findings should be taken into consideration when planning operative days involving THA.


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_IV | Pages 567 - 567
1 Nov 2011
Beaulé PE Smith F Powell JN Antoniou J Bourne RB Lavigne M Belzile E Schemitsch EH Garbuz D
Full Access

Purpose: Recently, there has been concern raised on the occurrence of pseudotumors after metal on metal hip resurfacing. A pseudotumor is defined as a local soft tissue mass associated with localized bony and/or tissue (muscle) destruction. The primary purpose of this study is to determine the incidence of this complication in several high volume Canadian academic centres.

Method: Nine of the 11 Canadian academic centres who perform metal on metal hip resurfacings were surveyed. The number of metal on metal hip resurfacing arthroplasties performed at each centre was first determined, as were the number of those who have presented with a pseudotumour, and subsequently gone on to revision surgery. The basic demographics of the group were recorded, as were the radiographic and implant design variables for those cases presenting with a pseudotumour.

Results: A sample of 3,400 hip resurfacing arthroplasties performed between 2002 and December 2008 were surveyed. Demographics were tabulated for a sub-sample of these patients. 76% were male, the mean length of follow-up was 3.02 years, mean BMI was 28.65, and mean age was 52.10 years. Three of 3,400 cases presented with a pseudotumour, an incidence of .09%.

Conclusion: Although pseudotumors remain a concern after metal on metal hip resurfacing, the incidence at short to mid term follow-up is very low in this multi-centre academic survey. This information is significantly lower than what other groups have recently reported. Continued close monitoring is required in order to determine what clinical factors are at play.